• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 62
  • 7
  • 3
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 78
  • 78
  • 42
  • 25
  • 25
  • 22
  • 19
  • 18
  • 18
  • 18
  • 18
  • 15
  • 14
  • 13
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

"Estudo dopplervelocimétrico das artérias uterinas em três períodos de gestações normais" / Study of the uterine arteries Doppler ultrasound in three periods of normal pregnancies

Kathia Sakamoto 02 October 2003 (has links)
Estudo longitudinal, prospectivo, comparativo de avaliação dopplervelocimétrica das artérias uterinas direita e esquerda em 37 gestantes normais em três períodos da gestação, acompanhadas na Clínica Obstétrica do HCFMUSP. Análise da relação S/D, índice de pulsatilidade e índice de resistência, relação com o número de incisuras e com posição da placenta. Foi observada redução nos valores dos índices durante a gestação. A relação S/D AUTE com placenta a direita apresentou média superior. A incidência de incisura foi maior no período entre a 16ª e a 24ª semana de gestação. A análise da relação entre os índices dopplervelocimétricos e a presença de incisura não teve resultados significativos / Prospective, longitudinal, comparative study of Doppler evaluation of the right and left uterine arteries of 37 healthy women with singleton pregnancies, performed in three periods of pregnancy, at the Pre-Natal Care Unit HCFMUSP. S/D ratio, pulsatility index and resistance index, number of notches and placental position were analysed. A decrease in the indices was observed with advancing gestation. When placenta was on the right side, the left uterine artery S/D ratio showed increased mean values. The incidence of uterine notch was higher between the 16th and 24th week of gestation in both arteries. No correlation was found between the presence of uterine notch and the placental position
72

"Estudo histopatológico comparativo de placentas oriundas de gestações com diástole zero ou reversa à dopplervelocimetria das artérias umbilicais" / Comparative histopathological study of placentas from pregnancies with absent or reversed end-diastolic velocity flow in the dopplervelocimetry of the umbilical arteries

Catia Cristine Chuba da Silva 22 March 2004 (has links)
Com o intuito de estudar a histopatologia da placenta na insuficiência grave desse órgão, foram selecionados preparados histológicos de 140 placentas oriundas de gestações com diástole zero (DZ) ou diástole reversa (DR) à dopplervelocimetria das artérias umbilicais, acompanhadas no Setor de Avaliação da Vitalidade Fetal da Clínica Obstétrica do HCFMUSP, de 1992 a 2000. Para tal fim, foram revisadas as lâminas histológicas arquivadas na Divisão de Anatomia Patológica do HCFMUSP. Em etapa inicial, foi efetuado um estudo descritivo das lesões encontradas e relatadas, em freqüência, no grupo de DZ e no grupo de DR. Na segunda etapa, os casos foram discriminados em cinco grupos, segundo uma classificação etiopatogênica, para cotejá-los aos aspectos clínicos como: idade gestacional (IG) no nascimento, ocorrência de restrição do crescimento fetal (RCF), peso do recém-nascido (RN) e peso da placenta. Em complemento, os grupos constituídos foram relacionados à gravidade da insuficiência placentária, confrontando-se os grupos de DZ e DR.A análise histopatológica demonstrou que o infarto viloso foi o tipo de lesão isolada mais freqüente, e que o Grupo 2 (Lesões envolvendo patologia vascular uteroplacentária e dano em vilosidades secundárias), foi o grupo etiopatogênico mais freqüente na população geral. Não houve correlação dos achados histológicos com a IG no nascimento, RCF e peso do RN. Nas placentas gravemente insuficientes (DR), a proporção de infartos vilosos, trombose intervilosa e as lesões pertencentes ao grupo 3 (lesões envolvendo coagulação) foi significativamente maior do que nas de gravidade menor (DZ). O conhecimento mais profundo dos mecanismos fisiopatológicos envolvidos na insuficiência placentária, cujos reflexos se manifestam nos achados histopatológicos, são essenciais para a busca de novas alternativas para promover melhorias na condução desses casos, principalmente no que concerne à instituição de terapêutica específica e adequada. No presente trabalho ficou evidente a importância da presença de lesões envolvendo coagulação como marcadores de gravidade na insuficiência placentária. / Histological features of 140 placentas from pregnancies with absent or reversed end-diastolic velocity flow were selected for the study of placental histopathology in cases of severe failure of the organ. All the pregnancies were followed-up in the Fetal Surveillance Unit of the Department of Obstetrics - HC FMUSP, from 1992 to 2000. For this purpose, the review of the histological features archived in the Department of Pathology - HCFMUSP was performed. The first step of the process involved a descriptive study of the findings reported, in frequency, in the AEDVF and REDVF groups. In the following step, cases were separated into five groups, according to an etiopathogenic classification, for the purpose of comparing clinical aspects such as: gestational age at birth, occurrence of fetal growth restriction, newborn weight and placental weight.In addition, the correlation between those groups and the severity of placental insufficiency/failure was analyzed, and both groups of absent and reversed end-diastolic velocity flow were compared. The histopathological analysis showed that villous infarcts were the most frequent lesion found in the histological features, and Group 2 (lesions involving uteroplacental vascular pathology and secondary villous damage) was the most frequent etiopathogenic group in general population. No correlation was found between the histological findings and gestational age, fetal growth restriction and weight of the newborn. In those placentas in which severe failure was detected, the proportional rate of villous infarcts, intervillous thrombosis and lesions found in Group 3 (lesions involving coagulation) was significantly higher than in those with less severe failure (absent end-diastolic velocity flow). Further studies of the pathophysiological mechanisms of placental insufficiency which result in the histopathological findings are essential for improving the follow-up in those cases, principally when specific and appropriate therapy is considered. In this study, the importance of the presence of lesions presenting coagulation as markers of severity in the placental insufficiency is evident.
73

Estudo prospectivo de eventos tromboembólicos após reoperações de alta complexidade em estimulação cardíaca artificial definitiva / Prospective study of thromboembolic events after high complexity reoperation in permanent artificial cardiac pacing

Albertini, Caio Marcos de Moraes 07 December 2017 (has links)
INTRODUÇÃO: Estenose e obstruções venosas são achados frequentes após o implante de cabos-eletrodos transvenosos. Manifestações clínicas dessas lesões venosas, entretanto, são raramente reportadas. Embora exista consenso de que fenômenos tromboembólicos sejam mais comuns após reoperações que envolvam o implante de novos cabos-eletrodos ou procedimentos de extração transvenosa, ainda não existem evidências que comprovem essa observação. OBJETIVOS: Em pacientes submetidos a reoperações para corrigir disfunção em cabos-eletrodos ou para mudar o modo de estimulação, o estudo visou identificar: a) a incidência de tromboembolia pulmonar (TEP) e de trombose venosa profunda (TVP) do membro superior ipsilateral ao procedimento; b) a prevalência de lesões venosas prévias ao procedimento cirúrgico, pelo estudo venográfico, e a ocorrência de modificações desse padrão seis meses após o procedimento; e c) fatores prognósticos para a ocorrência dos eventos clínicos e das alterações venográficas. MÉTODOS: No período de abril de 2013 a julho de 2016 foram estudados 84 pacientes. A avaliação pré-operatória incluiu: ultrassonografia com doppler dos membros superiores, angiotomografia de tórax com protocolo para TEP, venografia por subtração digital e coleta de biomarcadores laboratoriais específicos do sistema de coagulação e hemostasia. Os exames diagnósticos foram repetidos no momento pós-operatório para detectar os desfechos do estudo. Todos os pacientes foram acompanhados por 12 meses. Os desfechos primários foram a ocorrência de TEP ou TVP em até 30 dias após o procedimento. Os desfechos secundários foram as alterações venográficas no sexto mês após a intervenção cirúrgica. Na análise da associação das variáveis demográficas, clínicas, operatórias e laboratoriais com os desfechos do estudo, empregou-se os testes Qui-quadrado, Exato de Fisher ou \"t\" de Student. Modelos de regressão logística multivariados foram utilizados para identificar fatores prognósticos. RESULTADOS: Entre os 84 pacientes incluídos, houve equilíbrio entre os sexos e a idade média de 59,3 ± 15,2 anos. O principal motivo para realizar o procedimento cirúrgico foi a disfunção de cabos-eletrodos (75%). A remoção de cabos-eletrodos foi efetuada em 52,4% dos casos. A taxa de eventos clínicos e subclínicos pós-operatórios foi de 35,7%, representada por TVP em 24 (28,6%) casos e TEP em seis (7,1%). Alterações no padrão venográfico seis meses após a operação foram identificadas em 34,5% dos pacientes. Os fatores prognósticos independentes para TVP foram: a presença de circulação colateral significativa na venografia pré-operatória ([odds ratio (OR) = 4,7]), (intervalo de confiança de 95% (IC 95%); 1,1 - 19,8; P = 0,037), a extração transvenosa de cabos-eletrodos (OR = 27,4; IC 95%; 5,8 - 128,8; P < 0,0001) e o aumento do fibrinogênio no pós-operatório (OR = 1,02; IC 95%; 1,01 - 1,03; P = 0,018). O histórico de tabagismo foi o único fator prognóstico relacionado com a ocorrência de TEP (OR = 14,6; IC 95%; 2,3 - 91,8; P = 0,004). Somente a extração transvenosa de cabos-eletrodos foi fator prognóstico independente (OR = 5,0; IC 95%; 1,6 - 15,4; P = 0,004) para alterações venográficas pós-operatórias. CONCLUSÃO: Reoperações envolvendo o manuseio de território venoso com cabos-eletrodos previamente implantados apresentam elevados índices de complicações tromboembólicas e de alterações venográficas. Extração transvenosa de cabos-eletrodos apresentou impacto significativo no desenvolvimento de TVP e de alterações venográficas. Esses resultados mostram a necessidade de novos estudos específicos para avaliar o papel de estratégias preventivas para esse subgrupo de pacientes / INTRODUCTION: Venous stenosis or occlusion is a frequent finding in patients with previously-implanted transvenous leads. Clinical manifestations of these venous lesions, however, are rarely reported. Although there is a consensus that thromboembolic events are more frequent after reoperation involving the implantation of new leads or lead removal, there is still no evidence to support this observation. OBJECTIVES: In patients submitted to reoperations due to lead dysfunction or device upgrade, the study aimed to determine: a) the incidence of pulmonary embolism (PE) and upper extremity deep venous thrombosis (UEDVT) ipsilateral to the cardiac device; b) the prevalence of venous lesions determined by preoperative venography, and the occurrence of modifications or progression of these lesions six months after the procedure; and c) prognostic factors for clinical and venographic outcomes. METHODS: From April/2013 to July/2016, 84 patients were studied. The preoperative evaluation included: upper extremity venous ultrasound, computed tomography pulmonary angiography, digital subtraction venography and specific laboratory tests for coagulation and hemostasis. Diagnostic exams were repeated postoperatively to detect the study outcomes. All patients were followed for 12 months. Primary outcomes were occurrence of PE or UEDVT within 30 days after the procedure. Secondary outcomes were venographic changes six months after the surgical intervention. Student\'s t test, Chi-square or Fisher\'s Exact test were used in the univariate analysis of demographic, clinical, operative and laboratory variables. Multivariate logistic regression models were used to identify prognostic factors. RESULTS: Among the 84 patients included, there was a balance between gender and the mean age was 59.3 ± 15.2 years. Lead malfunctioning (75%) was the main surgical procedure indication. Lead removal was performed in 52.4% of the cases. The rate of postoperative clinical and subclinical events was 35.7%, represented by UEDVT in 24 (28.6%) cases and PE in 6 (7.1%). Alterations in the venography findings six months after the surgery were identified in 34.5% of the patients. Independent prognostic factors for UEDVT were: the presence of significant collateral circulation in the preoperative venography ([odds ratio (OR)= 4.7; [95% confidence interval (CI): 1.1 - 19.8; P=0.037), transvenous lead extraction (OR= 27.4; 95% CI 5.8-128.8; P < 0.0001) and fibrinogen variation (OR= 1.02; 95% CI 1.01 - 1.03; P=0.018). Smoking history was the only prognostic factor related to the occurrence of PE (OR= 14.6; 95% CI 2.3 - 91.8; P=0,004). Transvenous lead extraction was the only independent prognostic factor (OR= 5.0; 95% CI 1.6 - 15.4; P=0.004) for postoperative venographic endpoints. CONCLUSION: Reoperations involving previously transvenous implanted leads present high rates of thromboembolic complications and venographic alterations. Transvenous lead extraction had a significant impact on the development of UEDVT and venographic alterations. These results show the need for further studies to evaluate the role of preventive strategies for this subgroup of patients
74

Avaliação da extensão da oclusão arterial na isquemia crônica de membros inferiores: estudo comparativo da ecografia com Doppler colorido e da arteriografia / Assessment of the arterial occlusion extension in the lower extremity chronic ischemia: a comparative study of the duplex ultrasound and the arteriography

Ronald José Ribeiro Fidelis 07 November 2006 (has links)
A arteriografia é um exame radiológico invasivo que permite ver as características da luz das artérias tronculares e de pequenos ramos musculares e colaterais, tornando possível constatar alterações parietais mínimas através da injeção intravascular de meio de contraste. Apesar do grande desenvolvimento tecnológico que experimentou nas últimas décadas, tem limitações para definir a extensão da obstrução e o leito arterial pósobstrução na Doença Arterial Oclusiva de Membros Inferiores (DAO). Alguns estudos já analisaram a arteriografia quanto à visibilização do leito distal em pacientes com DAO femoropoplítea, porém nenhum estudou a extensão do segmento ocluído no território aortoilíaco utilizando a arteriografia intra-operatória com injeção distal de contraste como teste padrão. Este estudo clínico, prospectivo, conduzido no Serviço de Cirurgia Vascular do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, foi desenvolvido para avaliar a arteriografia pré-operatória em sua capacidade de detectar a real extensão das oclusões arteriais, e o leito arterial distal a estas. A Ecografia com Doppler colorido também foi avaliada nesses mesmos aspectos. A extensão da oclusão foi definida como sendo a distância entre o ponto de oclusão e o ponto de reenchimento (PR) da luz arterial, e o leito distal (LD) definido como o conjunto de todas as artérias que mantêm continuidade com este ponto de reenchimento. Todos os pacientes incluídos foram submetidos, em mesmo intervalo determinado de tempo, a uma Arteriografia com injeção de meio de contraste Proximal à obstrução (AP), uma Ecografia com Doppler colorido (Eco-Doppler) e ao padrão-ouro para diagnóstico do PR e LD, que é a Arteriografia com injeção de contraste Distal à obstrução (AD). Foram estudados 47 membros inferiores, de 33 pacientes. Trinta e quatro casos de doença aortoilíaca e 13 casos de doença arterial infrainguinal femoropoplítea. A AP detectou o verdadeiro PR em apenas 53,2% de toda a amostra, revelando uma reprodutibilidade ruim em relação à AD (k = 0,44, P < 0,001). Ao passo que o Eco-Doppler foi capaz de identificar o PR em 74,5% das vezes, revelando uma boa reprodutibilidade comparada ao teste padrão (k = 0,68, P < 0,001). Na visibilização do leito distal, a AP e o Eco-Doppler identificaram, respectivamente, 125 e 167 das 183 artérias vistas à AD. Esta diferença foi estatisticamente significativa (P = 0,001). Na análise da relação entre as variáveis estudadas e os resultados, o único fator significativamente associado com a discordância entre os métodos foi a localização anatômica da doença arterial. Com estes dados, concluí-se que a arteriografia préoperatória não identifica corretamente o PR e o LD em um número significativo de casos de DAO aortoilíaca. A Ecografia demonstrou neste estudo, uma concordância significativa com arteriografia intraoperatória, tanto na DAO aortoilíaca, quanto na femoropoplítea. / Arteriography is an invasive method of imaging the vascular system that allows assessment of the intraluminal characteristics of the arteries. It detects minimal arterial wall changes with intravascular injections of contrast agents. Dispite significant advances in lasts decades, some pitfalls remain in determining the extension of arterial occlusions and the run-off vessels in cases of arterial occlusive disease in the lower extremities (LEAOD). Some authors have already studied the extension of the disease, by arteriography, in patients with femoropopliteal disease; nevertheless, none of them has so far used the Intraoperative Distal Prebypass Arteriography (IDA) as the goldstandard in patients with disease in the aortoiliac territory. This study is a clinical, prospective trial, developed by the Division of Vascular Surgery at the University of Sao Paulo to analyse the pre-operative arteriography (POA) in its capacity of showing the true extension of the arterial occlusion and the run-off vessels in LEAOD. The Duplex Ultrasound Arterial Mapping (DUAM) was also tested in the same situations. Extension of the arterial occlusion was defined as the length between the point where the contrast agent leaves the main vessel, and the point where the contrast come back to it, in the arterial system, the later called Refilling Point (RP). Run-off was defined as the sum of the distal arteries continuous with the RP. All of the patients included in this study were subjected in a determined time interval to a POA, a DUAM and a IDA. Forty seven lower extremities were studied in 33 patients (34 with aortoiliac, and 13 with femoropopliteal disease). POA detected the true RP in 53% of the instances, with a bad reprodutibility of the gold-standard (k = 0,44, P > 0,001). The DUAM detected the RP 74,5%, with a good results reprodutibliity (k = 0,68, P < 0,001). In the assessment of run-off vessels POA and DUAM have detected, respectively, 125 and 167 of the 183 arteries showed in IDA. This disagreement between POA and DUAM was estastistically significant (P = 0,001). The only clinical characteristic associated with the results was the anatomical location of the arterial disease. We concluded that the POA does not identify the true RP and the run-off vessels in the aortoiliac LEAOD. The DUAM showed a good agreement with the IDA, and so it can be considered a good choice to assess the RP and the run-off in aortoiliac and femoropopliteal LEAOD.
75

Avaliação da administração intravenosa de solução salina hipertônica 7,5% como estratégia para melhorar a perfusão do tumor e a entrega de moléculas em modelos tumorais em camundongos / Evaluation of hypertonic saline solution 7,5% intravenous administration as a potential strategy to enhance tumor perfusion as well as molecular delivery in mice tumor models

Angelica Maria Patiño Gonzalez 20 December 2016 (has links)
A administração intravenosa de solução salina hipertônica (HSS) induz alterações sistêmicas circulatórias como o aumento da pressão arterial e do volume circulante efetivo, além de ter efeitos locais sobre a microcirculação. No presente estudo foram analisados os efeitos produzidos pela administração de solução salina hipertônica 7,5% sobre a hemodinâmica do tumor através de estudos de imagem funcional e posteriormente, foi avaliado o seu potencial de otimizar a entrega de moléculas no tumor. A velocidade do sangue nos vasos tumorais estimada por Ultrassom Color Doppler foi aumentada após a injeção da HSS em comparação ao controle PBS em tumores de melanoma (B16F10 (p=0,019), SK-MEL-147 (p =0,028)) e de mama (4T1 (p=0,015)). Este mesmo efeito não foi observado nas artérias segmentarias do rim (p=0,476). Ultrassonografia com contraste por microbolhas (CEUS) foi realizada em xenoenxertos de tumor de melanoma (B16F10), carcinoma de cólon (HCT-116) e mama (MDA-MB-231), e como controle foi realizada imagem no rim e no músculo nos animais portadores destes tipos tumorais (n=3 por grupo). Após a injeção da HSS, o volume relativo de sangue foi aumentado nos tumores B16F10 (p=0,022) e HCT-116 (P = 0,039), mas o mesmo não foi observado com o tumor MDA-MB-231 (p=0,186). Além disso, não houve alterações nos tecidos normais (rim p = 0,957; músculo p = 0,104). Todos os testes estatísticos foram bicaudais. Quando a HSS foi utilizada como veículo para entrega de moléculas de baixo peso molecular como cisplatina e doxorrubicina no tratamento de tumores B16F10 e 4T1 respectivamente, não houve aumento da eficácia terapêutica, avaliada através do crescimento tumoral e peso dos tumores. O efeito da HSS sobre a retenção de macromoléculas nos tumores SK-Mel- 147 e 4T1, avaliado através de imagem por epifluorescência do contraste ótico IR-783, não foi suficientemente notório para rejeitar a hipótese nula. Assim, a HSS induz um aumento transitório na velocidade do sangue e do volume sanguíneo, de maneira relativamente seletiva para os tumores avaliados, com exceção do MDA-MB-231. Portanto, esta pode ser uma estratégia útil para aumentar a entrega de moléculas e otimizar tanto o efeito terapêutico, quanto o diagnóstico por imagem / Intravenous administration of Hypertonic saline solution (HSS) induces systemic circulatory changes including blood pressure rising, effective circulating volume increase as well as local effects on microvasculature. We analyzed the effects produced by Hypertonic Saline 7,5% administration on tumor hemodynamics through functional imaging studies as well as whether it enhances molecular delivery in tumor tissue when used as a vehicle. Blood velocity assessed by Color Doppler Ultrasound was increased after HSS injection compared to PBS in the following tumors: B16F10 (p=0,019), SKMEL- 147 (p=0,028) and 4T1 (p=0,015). No statistical difference was observed on the segmental kidney arteries (p=0,476). Dynamic Contrast enhanced ultrasound (CEUS) was done in B16F10, HCT-116 and MDA-MB-231 tumor xenografts, kidney and muscle tissues (n=3 per group). After HSS injection, relative blood volume was increased in B16F10 (p=0,022) and HCT-116 (p=0,039) but not on MDA-MB-231 (p=0,186). Changes on normal tissues were not statistically different (kidney p=0,957; muscle p=0,104). All statistical tests were two-sided. Administration of HSS as a vehicle for low molecular weight molecules cisplatin and doxorubicin in the treatment of B16F10 and 4T1 tumors respectively had no significant improvement of therapeutic efficacy, estimated by tumor growth and tumor weight measurements. Effect of HSS over retention of macromolecules in tumors SK-Mel-147 and 4T1, evaluated by epifluorescence imaging of the optical contrast IR- 783 was not large enough to reject the null hypothesis. HSS induces a transient increase in velocity of the blood as well as the blood volume that is relatively selective for the evaluated tumors with exception of MDA-MB-231. Data suggest that HSS administration might be a useful strategy to increase the delivery of molecules and optimize both therapy and diagnostic imaging
76

Estudo prospectivo de eventos tromboembólicos após reoperações de alta complexidade em estimulação cardíaca artificial definitiva / Prospective study of thromboembolic events after high complexity reoperation in permanent artificial cardiac pacing

Caio Marcos de Moraes Albertini 07 December 2017 (has links)
INTRODUÇÃO: Estenose e obstruções venosas são achados frequentes após o implante de cabos-eletrodos transvenosos. Manifestações clínicas dessas lesões venosas, entretanto, são raramente reportadas. Embora exista consenso de que fenômenos tromboembólicos sejam mais comuns após reoperações que envolvam o implante de novos cabos-eletrodos ou procedimentos de extração transvenosa, ainda não existem evidências que comprovem essa observação. OBJETIVOS: Em pacientes submetidos a reoperações para corrigir disfunção em cabos-eletrodos ou para mudar o modo de estimulação, o estudo visou identificar: a) a incidência de tromboembolia pulmonar (TEP) e de trombose venosa profunda (TVP) do membro superior ipsilateral ao procedimento; b) a prevalência de lesões venosas prévias ao procedimento cirúrgico, pelo estudo venográfico, e a ocorrência de modificações desse padrão seis meses após o procedimento; e c) fatores prognósticos para a ocorrência dos eventos clínicos e das alterações venográficas. MÉTODOS: No período de abril de 2013 a julho de 2016 foram estudados 84 pacientes. A avaliação pré-operatória incluiu: ultrassonografia com doppler dos membros superiores, angiotomografia de tórax com protocolo para TEP, venografia por subtração digital e coleta de biomarcadores laboratoriais específicos do sistema de coagulação e hemostasia. Os exames diagnósticos foram repetidos no momento pós-operatório para detectar os desfechos do estudo. Todos os pacientes foram acompanhados por 12 meses. Os desfechos primários foram a ocorrência de TEP ou TVP em até 30 dias após o procedimento. Os desfechos secundários foram as alterações venográficas no sexto mês após a intervenção cirúrgica. Na análise da associação das variáveis demográficas, clínicas, operatórias e laboratoriais com os desfechos do estudo, empregou-se os testes Qui-quadrado, Exato de Fisher ou \"t\" de Student. Modelos de regressão logística multivariados foram utilizados para identificar fatores prognósticos. RESULTADOS: Entre os 84 pacientes incluídos, houve equilíbrio entre os sexos e a idade média de 59,3 ± 15,2 anos. O principal motivo para realizar o procedimento cirúrgico foi a disfunção de cabos-eletrodos (75%). A remoção de cabos-eletrodos foi efetuada em 52,4% dos casos. A taxa de eventos clínicos e subclínicos pós-operatórios foi de 35,7%, representada por TVP em 24 (28,6%) casos e TEP em seis (7,1%). Alterações no padrão venográfico seis meses após a operação foram identificadas em 34,5% dos pacientes. Os fatores prognósticos independentes para TVP foram: a presença de circulação colateral significativa na venografia pré-operatória ([odds ratio (OR) = 4,7]), (intervalo de confiança de 95% (IC 95%); 1,1 - 19,8; P = 0,037), a extração transvenosa de cabos-eletrodos (OR = 27,4; IC 95%; 5,8 - 128,8; P < 0,0001) e o aumento do fibrinogênio no pós-operatório (OR = 1,02; IC 95%; 1,01 - 1,03; P = 0,018). O histórico de tabagismo foi o único fator prognóstico relacionado com a ocorrência de TEP (OR = 14,6; IC 95%; 2,3 - 91,8; P = 0,004). Somente a extração transvenosa de cabos-eletrodos foi fator prognóstico independente (OR = 5,0; IC 95%; 1,6 - 15,4; P = 0,004) para alterações venográficas pós-operatórias. CONCLUSÃO: Reoperações envolvendo o manuseio de território venoso com cabos-eletrodos previamente implantados apresentam elevados índices de complicações tromboembólicas e de alterações venográficas. Extração transvenosa de cabos-eletrodos apresentou impacto significativo no desenvolvimento de TVP e de alterações venográficas. Esses resultados mostram a necessidade de novos estudos específicos para avaliar o papel de estratégias preventivas para esse subgrupo de pacientes / INTRODUCTION: Venous stenosis or occlusion is a frequent finding in patients with previously-implanted transvenous leads. Clinical manifestations of these venous lesions, however, are rarely reported. Although there is a consensus that thromboembolic events are more frequent after reoperation involving the implantation of new leads or lead removal, there is still no evidence to support this observation. OBJECTIVES: In patients submitted to reoperations due to lead dysfunction or device upgrade, the study aimed to determine: a) the incidence of pulmonary embolism (PE) and upper extremity deep venous thrombosis (UEDVT) ipsilateral to the cardiac device; b) the prevalence of venous lesions determined by preoperative venography, and the occurrence of modifications or progression of these lesions six months after the procedure; and c) prognostic factors for clinical and venographic outcomes. METHODS: From April/2013 to July/2016, 84 patients were studied. The preoperative evaluation included: upper extremity venous ultrasound, computed tomography pulmonary angiography, digital subtraction venography and specific laboratory tests for coagulation and hemostasis. Diagnostic exams were repeated postoperatively to detect the study outcomes. All patients were followed for 12 months. Primary outcomes were occurrence of PE or UEDVT within 30 days after the procedure. Secondary outcomes were venographic changes six months after the surgical intervention. Student\'s t test, Chi-square or Fisher\'s Exact test were used in the univariate analysis of demographic, clinical, operative and laboratory variables. Multivariate logistic regression models were used to identify prognostic factors. RESULTS: Among the 84 patients included, there was a balance between gender and the mean age was 59.3 ± 15.2 years. Lead malfunctioning (75%) was the main surgical procedure indication. Lead removal was performed in 52.4% of the cases. The rate of postoperative clinical and subclinical events was 35.7%, represented by UEDVT in 24 (28.6%) cases and PE in 6 (7.1%). Alterations in the venography findings six months after the surgery were identified in 34.5% of the patients. Independent prognostic factors for UEDVT were: the presence of significant collateral circulation in the preoperative venography ([odds ratio (OR)= 4.7; [95% confidence interval (CI): 1.1 - 19.8; P=0.037), transvenous lead extraction (OR= 27.4; 95% CI 5.8-128.8; P < 0.0001) and fibrinogen variation (OR= 1.02; 95% CI 1.01 - 1.03; P=0.018). Smoking history was the only prognostic factor related to the occurrence of PE (OR= 14.6; 95% CI 2.3 - 91.8; P=0,004). Transvenous lead extraction was the only independent prognostic factor (OR= 5.0; 95% CI 1.6 - 15.4; P=0.004) for postoperative venographic endpoints. CONCLUSION: Reoperations involving previously transvenous implanted leads present high rates of thromboembolic complications and venographic alterations. Transvenous lead extraction had a significant impact on the development of UEDVT and venographic alterations. These results show the need for further studies to evaluate the role of preventive strategies for this subgroup of patients
77

Jugular venous reflux and white matter abnormalities in Alzheimer's disease: a pilot study

Chung, C.P., Beggs, Clive B., Wang, P.N., Bergsland, N., Shepherd, Simon J., Cheng, C.Y., Ramasamy, D.P., Dwyer, Michael G., Hu, H.H., Zivadinov, R. January 2014 (has links)
yes / To determine whether jugular venous reflux (JVR) is associated with cerebral white matter changes (WMCs) in individuals with Alzheimer's disease (AD), we studied 12 AD patients 24 mild cognitive impairment (MCI) patients, and 17 elderly age- and gender-matched controls. Duplex ultrasonography and 1.5T MRI scanning was applied to quantify cerebral WMCs [T2 white matter (WM) lesion and dirty-appearing-white-matter (DAWM)]. Subjects with severe JVR had more frequently hypertension (p = 0.044), more severe WMC, including increased total (p = 0.047) and periventricular DAWM volumes (p = 0.008), and a trend for increased cerebrospinal fluid volumes (p = 0.067) compared with the other groups. A significantly decreased (65.8%) periventricular DAWM volume (p = 0.01) in the JVR-positive AD individuals compared with their JVR-negative counterparts was detected. There was a trend for increased periventricular and subcortical T2 WMC lesion volumes in the JVR-positive AD individuals compared with their JVR-negative counterparts (p = 0.073). This phenomenon was not observed in either the control or MCI groups. In multiple regression analysis, the increased periventricular WMC lesion volume and decreased DAWM volume resulted in 85.7% sensitivity and 80% specificity for distinguishing between JVR-positive and JVR-negative AD patients. These JVR-WMC association patterns were not seen in the control and MCI groups. Therefore, this pilot study suggests that there may be an association between JVR and WMCs in AD patients, implying that cerebral venous outflow impairment might play a role in the dynamics of WMCs formation in AD patients, particularly in the periventricular regions. Further longitudinal studies are needed to confirm and validate our findings.
78

Assessment of cerebral venous return by a novel plethysmography method

Zamboni, P., Menegatti, E., Conforti, P., Shepherd, Simon J., Tessari, M., Beggs, Clive B. January 2012 (has links)
BACKGROUND: Magnetic resonance imaging and echo color Doppler (ECD) scan techniques do not accurately assess the cerebral venous return. This generated considerable scientific controversy linked with the diagnosis of a vascular syndrome known as chronic cerebrospinal venous insufficiency (CCSVI) characterized by restricted venous outflow from the brain. The purpose of this study was to assess the cerebral venous return in relation to the change in position by means of a novel cervical plethysmography method. METHODS: This was a single-center, cross-sectional, blinded case-control study conducted at the Vascular Diseases Center, University of Ferrara, Italy. The study involved 40 healthy controls (HCs; 18 women and 22 men) with a mean age of 41.5 +/- 14.4 years, and 44 patients with multiple sclerosis (MS; 25 women and 19 men) with a mean age of 41.0 +/- 12.1 years. All participants were previously scanned using ECD sonography, and further subset in HC (CCSVI negative at ECD) and CCSVI groups. Subjects blindly underwent cervical plethysmography, tipping them from the upright (90 degrees ) to supine position (0 degrees ) in a chair. Once the blood volume stabilized, they were returned to the upright position, allowing blood to drain from the neck. We measured venous volume (VV), filling time (FT), filling gradient (FG) required to achieve 90% of VV, residual volume (RV), emptying time (ET), and emptying gradient (EG) required to achieve 90% of emptying volume (EV) where EV = VV - RV, also analyzing the considered parameters by receiver operating characteristic (ROC) curves and principal component mathematical analysis. RESULTS: The rate at which venous blood discharged in the vertical position (EG) was significantly faster in the controls (2.73 mL/second +/- 1.63) compared with the patients with CCSVI (1.73 mL/second +/- 0.94; P = .001). In addition, respectively, in controls and in patients with CCSVI, the following parameters were highly significantly different: FT 5.81 +/- 1.99 seconds vs 4.45 +/- 2.16 seconds (P = .003); FG 0.92 +/- 0.45 mL/second vs 1.50 +/- 0.85 mL/second (P < .001); RV 0.54 +/- 1.31 mL vs 1.37 +/- 1.34 mL (P = .005); ET 1.84 +/- 0.54 seconds vs 2.66 +/- 0.95 seconds (P < .001). Mathematical analysis demonstrated a higher variability of the dynamic process of cerebral venous return in CCSVI. Finally, ROC analysis demonstrated a good sensitivity of the proposed test with a percent concordant 83.8, discordant 16.0, tied 0.2 (C = 0.839). CONCLUSIONS: Cerebral venous return characteristics of the patients with CCSVI were markedly different from those of the controls. In addition, our results suggest that cervical plethysmography has great potential as an inexpensive screening device and as a postoperative monitoring tool.

Page generated in 0.052 seconds