• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • Tagged with
  • 7
  • 7
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Relação do Color Doppler e Power Doppler com densidade micro vascular intra tumoral corada com o anticorpo CD34 no câncer de mama /

Komatsu, Moisés Yoshifumi. January 2004 (has links)
Orientador: José Ricardo P. Rodrigues / Resumo: O aumento progressivo nas últimas décadas na incidência do câncer de mama é um fato que assola a humanidade, entretanto, as taxas de mortalidade tendem ao decréscimo em virtude da detecção precoce através de métodos de rastreio não invasivos, e do conhecimento cada vez maior do comportamento biológico do tumor. A maior adesão aos meios de rastreamento existentes hoje, deve-se não apenas ao medo que o câncer provoca nas mulheres, mas também ao fato dos exames utilizados para este rastreio não serem invasivos. Infelizmente, ainda não existem métodos capazes de dar indícios do comportamento biológico do tumor de forma instantânea, sem que haja a necessidade de submeter as pacientes portadoras de tumores malignos da mama a procedimentos cirúrgicos. Desde o início da última década do século XX, tem-se estudado a angiogênese do tumor através da ultra-sonografia, utilizando-se dos recursos de Color Doppler e Power Doppler. Neste trabalho, realizado no Hospital Santa Marcelina de Itaquaquecetuba, em conjunto com a Disciplina de Mastologia da Faculdade de Medicina de Botucatu - UNESP, foram estudadas trinta e cinco pacientes com tumores malignos da mama, onde os parâmetros hemodinâmicos (Índice de Resistência, Índice de Pulsatibilidade e a Velocidade Máxima no Pico Sistólico) através do Color Doppler... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Although a progressive increase in the incidence of breast cancer is a fact that plagues mankind, mortality rates tend to decrease given precocious detection using non-invasive tracking methods and an ever-growing knowledge of tumoral biological behaviour. The current large adhesion to tracking methods is explained not only by the fear cancer raises in women but also to the use of non-invasive exams. Unfortunately, there are no methods capable of giving instantaneous indication of tumoral biological behaviour without submitting patients with malignant tumors to surgical procedure. Since the early nineties and now at the dawn of the 21st Century, the angiogenesis of the tumor is being studied with the help of Color Doppler and Power Doppler ultrasonography. In this research - carried out at Santa Marcelina Hospital in Itaquaquecetuba in cooperation with the Department of Mastology of the Botucatu Medical School, São Paulo State University, thirty five patientes with mammary malignat tumors were... (Complete abstract click electronic access below) / Mestre
2

Padronização e comparação dos valores ecobiométricos e eletrorretinográficos em cães hígidos das raças Terrier Brasileiro e Beagle /

Guimarães, Patrícia Jordão. January 2011 (has links)
Orientador: José Luiz Laus / Coorientador: Alexandre Pinto Ribeiro / Banca: Alexandre Lima de Andrade / Banca: Cristiane dos Santos Honsho / Resumo: Com a pesquisa, objetivou-se padronizar e comparar valores ecobiométricos e eletrorretinográficos em cães das raças terrier brasileiro e beagle. Utilizaram-se vinte cães, sendo dez da raça terrier brasileiro e dez da beagle, machos e fêmeas hígidos. A ecobiometria foi realizada por ultrassonografia em modos A e B sob contenção física. Avaliaram-se o diâmetro axial do olho, a espessura da lente e os comprimentos das câmaras anterior e vítrea. A eletrorretinografia foi realizada de acordo com o protocolo Dog Diagnostic Protocol sob anestesia com propofol. Os dados foram analizados em software HMsERG, onde mensuraram-se as amplitudes e os seus respectivos tempos implícitos. Em ambas as raças estudadas, não se observaram diferenças significativas entre os olhos direito e esquerdo, quanto aos valores mensurados à ecobiometria ocular (p>0,05). Todavia, os valores relativos ao comprimento axial (p=0,023) e a câmara anterior (p=0,01) de cães da raça beagle foram significativamente maiores que os da raça terrier brasileiro. Nos períodos de resposta de adaptação dos bastonetes, não houve diferença estatística entre as raças (p>0,05). Relativamente à resposta mista, embora sem diferença estatística, observou-se que as amplitudes das ondas A (p=0,24) e B (p=0,23) na raça terrier brasileiro, foram respectivamente, 51,78% e 17,30% maiores que na raça beagle. Não houve significância para valores de onda B nas fases fotópticas, entretanto, o tempo implícito na raça beagle foi significativamente maior (p=0,03) na fase clara com luz estroboscópica. Conclui-se que a câmara anterior e o diâmetro axial do bulbo dos olhos de beagles apresentam comprimentos significativamente maiores que os de terrier braileiros. Embora os parâmetros eletrorretinográficos não tenham diferido significativamente entre as... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of the present study were to standardize and compare echobiometric and eletrorretinographic values in the brazilian terrier and beagle breeds. Twenty healthy dogs, being ten brazilians terrier and ten beagles, of both gender, were employed in this study. The echobiometry was accomplished by means of A and B mode ultrassonography under physical restrain. Axial globe length, lens thickness, anterior and vitreous chamber depth were evaluated. Electroretinography was performed using the Dog Diagnostic Protocol under anesthesia with propofol. Eletroretinographic recordings were evaluated with specific software, where the A and B wave amplitudes and their implicit times were measured. Echobiometric values did not change significantly between right and left eyes in both breeds (P>0.05). During rod response data did not change significantly between breeds (P>0.05). On mixed response, statistical difference was not observed, however, A (P=0.24) and B (P=0.23) wave amplitudes were, respectively, 51.78% and 17.30% higher in brazilian terrier breed. During the photoptic period, B wave amplitudes did not change significantly, however the implicit time seen with stroboscopic light was significantly higher (P=0.03) in beagles. It is concluded that anterior chamber depth and axial globe length were significantly higher in beagles than in brasilian terriers. Though, eletroretinographic values did not change significantly between breeds, higher amplitudes and shorter implicit time were seen in brazilian terriers, suggesting that such findings may be related to its smaller eyes / Mestre
3

Ultrassonografia transcraniana em cães adultos hígidos : padronização da técnica, aspectos anatômicos e biométricos /

Cintra, Thassila Caccia Feragi. January 2011 (has links)
Resumo: Com este trabalho objetivou-se correlacionar a ultrassonografia transcraniana com a anatomia encefálica, confeccionar um atlas com cortes anatômicos do encéfalo, à similitude dos planos de varredura ultrassonográficos, identificando e mensurando nas imagens as estruturas encefálicas visibilizadas, para padronizar dimensões em cães mesaticéfalos. Foram utilizados 37 cães adultos, hígidos, sem raça definida, sendo 30 in vivo e sete cadáveres. Nos cadáveres, após varredura, as cabeças foram removidas e seccionadas em planos anatômicos à similitude dos planos ultrassonográficos. Nos animais in vivo a identificação e as mensurações das estruturas encefálicas foram comparadas entre si para avaliar a repetibilidade da varredura eletrônica. No encefálo foram realizados cortes ultrassonográficos em planos dorsais e dorsais oblíquos pela janelas temporal e occipital, sendo passível visibilizar regiões dos lobos frontal, temporal e occipital, ventrículos laterais, septo pelúcido, fissura longitudinal do cérebro, sulcos suprasilviano, marginal e coronal, cerebelo, tentório ósseo do cerebelo, vermes do cerebelo, e medula oblonga. As médias e os desvios padrão das estruturas encefálicas nos 30 cães in vivo não variaram (p>0,05) em função das janelas temporais e foram 0,277cm ± 0,030 e 0,281cm ± 0,024; 1,643cm ± 0,115; 0,161 ± 0,021 e 0,157 ± 0,016; 2,248 ± 0,166 e 2,368 ± 0,212, respectivamente para largura dos ventrículos laterais direito e esquerdo; manto encefálico; espessura dos sulcos marginal e coronal; diâmetros ventro-lateral e crânio-caudal da região cerebelar / Abstract: The goals o this study were to correlate transcranial ultrasonography with brain anatomy, to make an atlas with anatomical cuts of the brain that were similar to the ultrasound plane images, to identify and to measure the brain structures visualized, in order to standardize their dimensions in mesaticephalic dogs. In this experiment, 37 adult, healthy mongrel dogs were used - 30 alive and 7 corpses. After the ultrasound procedure the head of the corpse was removed and cut in anatomical planes as the ultrasound plane images. In the live animals, the brain structures identification and measurements were compared to each other to assess the reprodutibility of the ultrasound procedure. Ultrasound scans in dorsal and dorsal oblique planes were performed in the brain through the temporal and occipital window, with visualization of the frontal, temporal and occipital lobe, lateral ventricles, septum pellucidum, the longitudinal fissure of the brain, suprasylvian, marginal and coronal sulcus, cerebellum, the osseous tentorium of the cerebellum, the vermis of the cerebellum and the medulla oblongata. The average and the standard deviation of the brain structures of the 30 live dogs did not vary (p>0,05) in both temporal window and were 0,277cm ± 0,030 e 0,281cm ± 0,024; 1,643cm ± 0,115; 0,161 ± 0,021 e 0,157 ± 0,016; 2,248 ± 0,166 e 2,368 ± 0,212, respectively for width of the right and left lateral ventricles and cerebral mantle, thickness of the marginal and coronal sulcus, and ventrolateral and canio-caudal cerebellar diameter / Orientador: Júlio Carlos Canola / Coorientador: Cibele Figueira Carvalho / Banca: Márcia Rita Fernandes Machado / Banca: Tilde Rodrigues Froes / Mestre
4

Ultrassonografia do bulbo do olho de cães, com diferentes conformações cranianas /

Toni, Maria Carolina. January 2011 (has links)
Orientador: Júlio Carlos Canola / Banca: José Luiz Laus / Banca: Fabrício Singaretti de Oliveira / Resumo: Com o presente estudo pretendeu-se conhecer os valores médios para as estruturas intraoculares e compará-los entre cães com diferentes conformações cranianas por meio da ultrassonografia ocular com transdutor de 20 MHz. Foram selecionados 30 cães, adultos, peso corpóreo até 10 kg, machos ou fêmeas, hígidos, atendidos no Hospital Veterinário "Governador Laudo Natel" - Faculdade de Ciências Agrárias e Veterinárias - UNESP - Câmpus de Jaboticabal. Os cães foram distribuidos em três grupos: G1 - 10 braquicefálicos, G2 - 10 mesocefálicos e G3 - 10 dolicocefálicos. Na análise estatística realizada pelo teste t Student com nível de significância de 5%, não houve diferença entre os olhos direito e esquerdo dos cães do mesmo grupo (p > 0,05). Valores médios e desvios padrão foram obtidos para profundidade da câmara anterior (D1), espessura da lente (D2), profundidade da câmara vítrea (D3) e comprimento axial do bulbo do olho (D4) nos três grupos. G1: D1 2,92mm (± 0,37), D2 7,03mm (± 0,61), D3 9,48mm (± 0,74) e D4 19,43mm (± 0,60). G2: D1 3,08mm (± 0,67), D2 7,02mm (± 0,87), D3 8,76mm (± 1,23) e D4 18,86mm (± 1,45). G3: D1 3,07mm (± 0,65), D2 7mm (± 0,81), D3 9,75mm (± 0,98) e D4 19,82mm (± 0,95). Para comparação dos valores médios de D1, D2, D3 e D4 entre os grupos, foi utilizado o teste de Tukey, com nível de significância de 5%. Na análise de D3, foi observada diferença (p < 0,05) na comparação entre G2 e G3. Na análise de D4, foi observada diferença (p < 0,05) na comparação entre G2 e G3 / Abstract: The present study aimed to know the average values of the intraocular structures and compare among different skulls' conformations in dogs using ocular ultrasonography with 20 MHz probe. They were selected 30 healthy adult dogs, body weight 10 kg, male or female, assisted at "Governador Laudo Natel" Veterinary Teaching Hospital - Faculdade de Ciências Agrárias e Veterinárias - UNESP - Campus of Jaboticabal. Animals were divided into three groups: G1 - 10 brachycephalic dogs, G2 - 10 mesocephalic dogs and G3 - 10 dolicocephalic dogs. The Student t test at 5% significance level was used to compare difference between right and left eyes of the dogs in the same group and no difference was found (p > 0.05). Mean and standard deviations were obtained for anterior chamber depth (D1), lens thickness (D2), vitreous chamber depth (D3) and axial length of the eye globe (D4) in the three groups. G1: D1 2.92mm (± 0.37), D2 7.03mm (± 0.61), D3 9.48mm (± 0.74) and D4 19.43mm (± 0.60). G2: D1 3.08mm (± 0.67), D2 7.02mm (± 0.87), D3 8.76mm (± 1.23) and D4 18.86mm (± 1.45). G3: D1 3.07mm (± 0.65), D2 7mm (± 0.81), D3 9.75mm (± 0.98) and D4 19.82mm (± 0.95). The Tukey test at 5% significance level was used to compare the average of D1, D2, D3 and D4 among groups. Differences between G2 and G3 were found (p <0.05) when comparing D3 and D4 / Mestre
5

Estudo dos aspectos anatômicos da articulação temporo-hióide de equinos por meio da radiografia convencional, ultrassonografia articular e tomografia computadorizada /

Santos, Taízha Cristine Ciasca dos. January 2009 (has links)
Orientador: Luiz Carlos Vulcano / Banca: Ana Liz Garcia Alves / Banca: Joffre Guazzelli Filho / Banca: Stefano Carlo Filippo Hagen / Banca: Masao Iwasaki / Resumo: Este estudo teve como objetivo, utilizando para tanto 22 cabeças de cadáveres equinos sadios, obtidas em abatedouro frigorífico, avaliar comparativamente de forma minuciosa e detalhada a anatomia da articulação temporo-hióide de equinos, por meio do exame radiográfico convencional, ultrassonográfico articular e tomográfico. Ambas as articulações, direita e esquerda, foram avaliadas. As imagens obtidas pelos três métodos foram identificadas e agrupadas sob aspecto das imagens que se repetem, que se somam e que se complementam, além da realização de avaliação minuciosa das características anatômicas da articulação temporo-hióide como um todo pelos diferentes acessos diagnósticos, buscando o meio de diagnóstico menos agressivo, não invasivo, rápido e de relativo baixo custo quando comparados. Observou-se que a tomografia visibilizou sempre de forma clara, ou seja, com melhor qualidade e precisão, todas as características e estruturas avaliadas. Já o raios-x e a ultrassononografia variaram bastante, algumas vezes de forma positiva, em concordância com a tomografia, outras nem tanto, limitando a avaliação de determinadas estruturas por estes métodos. Os três métodos de diagnóstico demonstraram uma concordância plena significativa (93,18%) apenas em relação à sua localização anatômica, o que não significa que os três métodos não podem gerar informações adicionais de grande valia. Concluiu-se que a TC é superior aos outros métodos, porém os três podem ser aliados no sentido de que se complementam, repetindo e somando imagens e informações importantes na escolha de um tratamento e na avaliação de seu prognóstico. Estes resultados propõem referências de abordagem que adicionarão informações na avaliação da região da articulação temporo-hióide dos equinos. / Abstract: Twenty-two equine heads obtained from healthy slaughtered horses were analyzed through conventional radiography, articular ultrasonography and Computed Tomography (CT). Both left and right joints were evaluated. Images obtained by the three methods were identified and grouped according to different aspects: repeated images, added images and complementary images. In addition, images were thoroughly evaluated for anatomical characteristics of the temporohyoid joint as a whole by the different diagnostic accesses, in an attempt to obtain a less aggressive, non-invasive, fast and relatively inexpensive diagnosis. Tomography always showed the evaluated characteristics and structures very clearly, i.e., with better quality and precision. In contrast, x-ray and ultrasonography varied significantly, sometimes positively, in agreement with tomography, and in other instances negatively, limiting the evaluation of certain structures by those methods. The three diagnostic methods showed a significant concordance (93.18%) only in relation to the anatomical localization. This, however, does not mean that the three methods may not generate additional useful information. It was concluded that CT is a superior method than the others, although the three methods are complementary and can be combined, by repeating and adding important images and information when choosing a treatment and in the evaluation of the prognostics. These results define a reference of access that will add information in the evaluation of the equines temporohyoid joint. tomography, articular ultrasonography. / Doutor
6

Avaliação estrutural da próstata de cães : comparação entre punção aspirativa com agulha fina guiada por ultra-som e biópsia por videolaparoscopia /

Paula, Thaís Melo de. January 2008 (has links)
Orientador: Gilson Hélio Toniollo / Banca: Antonio Carlos Alessi / Banca: Fabiana Ferreira de Souza / Resumo: A próstata é o único órgão sexual acessório no cão e as afecções prostáticas são comuns em cães adultos a idosos. A história clínica, anamnese, sinais clínicos e exames complementares, como a radiografia, ultra-sonografia, citologia e a histopatologia auxiliam no diagnóstico, embora o diagnóstico definitivo se fundamenta no exame histopatológico da próstata. Neste estudo, 11 animais da espécie canina, machos, adultos, não castrados e hígidos foram submetidos à punção aspirativa com agulha fina guiada por ultra-som para avaliação citológica e, após, um mínimo sete dias, utilizou-se da videolaparoscopia para obtenção de fragmento prostático para avaliação histopatológica. Nos exames citológicos, dois animais apresentaram alterações celulares compatíveis com hiperplasia prostática benigna. Durante as videolaparoscopias, a colheita do fragmento prostático foi realizada de maneira rápida, não sendo observada hemorragia significativa após o procedimento. Os animais não apresentaram nenhuma complicação no período pós-operatório. Verificou-se, aos exames histopatológicos, morfologia e estrutura celulares e teciduais nos padrões normais do parênquima prostático, em nove animais; os dois restantes apresentaram alterações celulares e teciduais sugestivas de hiperplasia prostática benigna. / Abstract: The prostate is the only sexual accessory gland in the male dog. The prostate diseases are common in adult and geriatric dogs. The clinical history, anamnesis, clinical signs and complementary exams, as radiography, ultrasonography, cytology and histopathology are helpful for the diagnosis, despite the definitive diagnosis is based on prostate histopathologic exams. In this study, 11 healthy intact male dogs were submitted to ultrasound fine needle aspirative puncture for cytologic exam and after, at least 7 days later, by videolaparoscopic fragment collection for further histopathologic evaluation. On cytologic exams, two animals presented changes which correlates with benign prostatic hyperplasia. During the videolaparoscopic proceedings, the prostate fragment collections were made in a quick way and no important hemorrhagic lost has been seen after the collection. The animals presented no complication after the surgeries. The histopathologic exams showed normal prostate parenchyma based on the cellular and tissue morphology and structure in 9 dogs, and the others 2 presented cellular and tissue changes suggesting benign prostatic hyperplasia. / Mestre
7

Estudo prospectivo do diagnóstico por imagem em cães com ruptura do ligamento cruzado cranial. -

Oliveira, Rodrigo dos Reis. January 2006 (has links)
Orientador: Maria Jaqueline Mamprim / Banca: Lucy Mary / Banca: Ribeiro Muniz / Banca: Nilva Maria / Banca: Esteves Mascarenhaz / Resumo: exame radiográfico e a ultra-sonografia foram avaliados como técnicas de imagem no diagnóstico de ruptura do ligamento cruzado cranial (LCCr) em cães. Verificou-se sexo, raça, peso e idade dos animais atendidos no Hospital Veterinário (HV) da Faculdade de Medicina Veterinária e Zootecnia (FMVZ)-UNESP, Botucatu-SP. Num período de 12 meses, 31 cães com suspeita de ruptura do LCCr foram submetidos a exames radiográficos e ultra-sonográficos com objetivo de verificar sinais compatíveis com a lesão. Os casos positivos foram encaminhados para cirurgia, no intuito de confirmar o diagnóstico O e reparar a lesão. Foram verificados por meio de artrotomia 23 casos de ruptura total e dois casos de ruptura parcial do LCCr. Não houve diferença significativa entre machos e fêmeas, bem como entre animais inteiros ou castrados. Os cães sem raça definida foram os mais acometidos, seguidos pelo boxer, pit bull, pastor alemão e rottweiler. O animal mais leve pesava 8,4kg e o mais pesado 71kg, sendo a média igual a 27,9kg. Cães com peso igual ou inferior a 15kg apresentaram uma ocorrência menor da doença quando comparados aos animais com peso acima de 15,1kg. A faixa etária variou entre 12 meses a 13 anos, não sendo verificada variação considerável ao compararmos animais jovens e maduros. O exame radiográfico diagnosticou corretamente a lesão em 84% (21) dos casos, e quatro (16%) animais tiveram resultado falso-negativo. O exame ultra-sonográfico foi capaz de diagnosticar acertadamente 76% dos casos, e fornecer diagnóstico favorável nos 24% restantes, apresentando 100% de resultados positivos. No presente trabalho pudemos concluir que tanto o exame radiográfico quanto a ultra-sonografia são modalidades que podem contribuir de forma positiva no diagnóstico da ruptura do LCCr em cães. / Abstract: Radiographic and ultrasonographic examination was evaluated as image techniques in diagnostic of cranial cruciate ligament (CCL) rupture in dogs. Was determined the sex, breed, body weight and age of the animals taken care in the Hospital Veterinarian (HV) of the Faculdade de Medicina Veterinária e Zootecnia (FMVZ)-UNESP, Botucatu-SP. In a period of 12 months, 31 dogs with supposed CCL rupture were examined radiographic and ultrasonographically with objective to verify compatible signals with the injury. Positive cases had been directed for surgery, in intention to confirm the diagnostic and to repair the injury. Had been verified by artrotomy 23 cases of total rupture and two cases of partial rupture of the CCL. Did not have significant difference between males and females, as well as between intact or neutered animals. Mixed breeds had been affected, followed for boxer, pit bull, german shepherddog and rottweiler. The animal lightest weighed 8,4kg and the heaviest 71kg, mean body weight was 27,9kg. Dogs with equal or inferior weight 15kg had presented a lesser occurrence of the illness when compared with the animals with weight above of 15,1kg. Age varied enters 12 months and 13 years, without considerable variation between mature and young animals. Radiology correctly identified the injury in 84% of the cases, and four (16%) animals had false-negative resulted. In 76% of cases, ultrasonography correctly identified, and to supply to favorable diagnosis in 24% remains, presenting 100% of positive results. In the present study we could conclude that as radiology how ultrasonography are modalities diagnostics that can contribute of positive form in the diagnosis of the rupture of the CCL in dogs. / Mestre

Page generated in 0.0877 seconds