Spelling suggestions: "subject:"ultrasound,"" "subject:"ltrasound,""
1031 |
Comparison of pain relief and functional improvement in landmark vs. ultrasound-guided corticosteroid injections for adhesive capsulitis: a prospective studyCoene, Ryan Patrick 12 July 2017 (has links)
BACKGROUND: Adhesive capsulitis is an idiopathic disorder of the shoulder that is characterized by pain in combination with the gradual loss of passive and active range of motion. It is typically self-limiting, although the disease still remains poorly understood. However, there are several treatment modalities, both conservative and surgical, that provide significant clinical benefit for patients with adhesive capsulitis. Corticosteroid injections are an established conservative treatment method for adhesive capsulitis. Several studies have demonstrated that injections provide short-term benefits in terms of shoulder mobility and pain reduction. The intra-articular injections can be performed blindly (landmark) or with ultrasound (US) guidance. Physicians administer injections under US guidance in an attempt to improve the accuracy of the injection. However, it remains unclear whether US-guided injections relieve symptoms of adhesive capsulitis more effectively than landmark injections.
OBJECTIVE: To compare the pain relief, self-reported function, and shoulder range of motion (ROM) outcomes of landmark versus US-guided corticosteroid injections for adhesive capsulitis.
Methods: A total of 21 patients with adhesive capsulitis were randomized to receive either a landmark or US-guided intra-articular corticosteroid injection. Clinical outcome measures were documented at baseline, 6 weeks, and 12 weeks. These measures included a visual analog scale (VAS) for pain, the Single Assessment Numeric Evaluation (SANE) score for self-reported function, and passive shoulder ROM, including forward flexion, external rotation, and abduction.
RESULTS: Both US-guided and landmark glenohumeral (GH) joint injections significantly improved VAS scores, SANE scores, and shoulder ROM outcomes. Improvement was maintained for all outcome measures in both groups throughout the 12 week treatment period. However, there were no significant differences seen in outcome measures between the two groups except that US-guided provided greater improvement in abduction at the 6 week follow-up (P = .004).
CONCLUSIONS: This preliminary report found that there is no significant difference in the effectiveness of US-guided and landmark cortisone injection in terms of pain improvement, self-reported functions, and ROM outcomes for adhesive capsulitis.
|
1032 |
Avaliação radiográfica e ultra-sonográfica do aparato podotroclear dos cavalos da raça Quarto de Milha acometidos pela síndrome do navicular /Peixoto, Cintia Iolanda Coutinho. January 2007 (has links)
Resumo: O objetivo deste estudo foi avaliar as alterações do aparato podotroclear dos cavalos da raça Quarto de Milha acometidos pela doença do navicular utilizando o acesso transcuneal. Foram utilizados 22 animais oriundos da região de Botucatu e Bauru-SP. Estes animais foram submetidos ao exame radiográfico e ultra-sonográfico. No exame radiográfico foi observada a presença de invaginação sinovial de diferentes tipos, além calcificação da bursa podotroclear e tendão flexor digital profundo, entesiófitos, osteófitos e alteração do limite córtico-medular. No exame ultra-sonográfico observou-se alterações da bursa podotroclear, aderência e irregularidades nos bordos do tendão flexor digital profundo, diminuição do coxim digital, calcificação do ligamento sesamóide distal ímpar e irregularidade da superfície flexora do osso sesamóide distal. Todos os animais que apresentavam alteração radiográfica e também apresentaram alteração no exame ultra-sonográfico compatível com a doença do navicular. O exame ultra-sonográfico utilizando o acesso transcuneal foi um método prático e eficiente para avaliação das lesões do aparato podotroclear dos eqüinos, sendo um método complementar ao exame radiográfico. / Abstract: The objective of this study was to evaluate the podotrochlear apparatus using a transcuneal approach in American Quarter horses suffering from navicular disease. 22 horses from the area of Botucatu and Bauru in São Paulo were evaluated. On those patients, radiographic and ultrasonographic evaluations were performed. On radiograph, different kinds of synovial invaginations, calcifications of the podotrochlear bursa and deep digital flexor tendon, enthesiophytes, osteophytes, and alterations in the cortical-medullary margin were observed. On the ultrasound scans, alterations of the podotrochlear bursa, adherences and irregularities at the surface of the deep digital flexor tendon, diminution of the digital cushion, calcifications of the impar distal sesamoideal ligament, and irregularities of the flexor surface of the distal sesamoid bone were observed. Radiographic and ultrasonographic alterations compatible with navicular disease were present in all of the patients. Ultrasonography using transcuneal approach was a practical and efficient method for evaluating podotrochlear apparatus injuries in equine, thus being a complementary method to radiography. / Orientador: Luiz Carlos Vulcano / Coorientador: Vânia Maria de Vasconcelos Machado / Banca: Ana Liz Garcia Alves / Banca: Stefano Carlo Filippo Hagen / Mestre
|
1033 |
Exploring a vascular cause for chronic pelvic pain in womenHansrani, Vivak January 2017 (has links)
Objectives: Pelvic vein incompetence (PVI) has been suggested as a cause for chronic pelvic pain. The overall objective of this thesis is to determine how PVI affects women, identify suitable methods of diagnosis and provide evidence regarding its association with chronic pelvic pain. This thesis will also evaluate the evidence behind its treatment. Methods: Four observation studies were completed during this thesis. A characterisation study encompassing 120 participants was performed to determine symptoms commonly experienced by women with PVI. Two observation studies analysed the ability of trans-vaginal ultrasound to detect PVI and compared its accuracy with reflux venography; considered the reference standard. A further 70 participants were recruited in a case-control study to determine the prevalence of PVI in women with and without chronic pelvic pain. A randomised control trial treating women with PVI and pelvic pain was also designed. Results: Women with PVI had an increased frequency of CPP when compared with healthy controls or women with varicose veins. This pain was associated with the menstrual cycle and intercourse. It was also found to frequently radiate into the upper thighs. Trans-vaginal ultrasound was shown to have a sensitivity and positive predictive value of 100% and 95% respectively when compared with reflux venography. The frequency of PVI in women with chronic pelvic pain was found to be 47% compared with 25% in women with no history of CPP (p < 0.001). Conclusion: The results of this thesis suggest PVI to be a possible cause of CPP in women and likely to be under-diagnosed. It can be identified by trans-vaginal ultrasound although the degree of accuracy is still yet to be determined. PVI merits further research and attention from clinicians and researchers. The proposed randomised control trial is needed both to further understanding of the role of PVI in CPP and to assess the efficacy of an under-researched treatment approach currently used in practice.
|
1034 |
Caractérisation et modélisation de l’endommagement des géomatériaux par méthode ultrasonore / Caracterization and modeling of damage geomaterials by ultrasonic methodBui, Truong Son 19 May 2014 (has links)
Ce travail de recherche est consacré à l’étude de l’endommagement des géomatériaux en utilisant la méthode non destructive par ultrasons. Pour atteindre cet objectif, nous développons dans un premier temps un dispositif à ultrasons modern et novateur qui, en combinant avec un système de sollicitation mécanique, permet de caractériser le processus de l’endommagement du matériau au cours des essais telle que la compression uniaxiale/triaxiale. Plus précisément, le système ultrasonore construit comporte 96 voies et au cours des essais il est capable de mesurer de manière continue les trois types des ondes grâces aux capteurs piézoélectriques spécifiques.L’application de ce système ultrasonore à la caractérisation de l’endommagement des géomatériaux à matrice cimentaire a montré l’efficacité de cette approche. Au cours des essais de compression uniaxiale, l’évolution de la vitesse et de l’atténuation de trois types d’onde a été mise en évidence comme conséquence de l’endommagement au sein du matériau. Nous nous intéressons dans un deuxième temps l’application du système ultrasonore à capturer les images d’endommagement progressif à travers les tomographies des vitesses et de l’atténuation des ondes. L’étude sur les éprouvettes de mortier donne des résultats concordants avec les observations, surtout à la rupture, bien que la résolution reste assez grossière. La dernière partie de ce travail de recherche vise à modéliser l’endommagement du matériau par une approche dite changement d’échelle. Un modèle conceptuel est proposé pour ce type de matériau qui permet de prendre en compte deux mécanismes principaux d’endommagement : la propagation des fissures au sein de la matrice cimentaire et la décohésion entre les inclusions et la matrice. Via un schéma d’homogénéisation en deux étapes, l’influence de ces mécanismes sur l’évolution des vitesses des ondes ultrasonores a été élucidée. Une comparaison des prédictions numériques avec les résultats expérimentaux permet de valider le modèle utilisé. / This research is devoted to study the damage of geomaterials using the nondestructive method like ultrasound. To this aim, we develop in the first step a modern and innovative system of ultrasound which, in combining with a mechanical system, can characterize the process of damage in material during the tests such as uniaxial/triaxial compression. More specifically, our ultrasonic system comprises 96 channels and can be able to measure continuously the three types of waves thanks to the specific piezoelectric sensors.The application of the developped system for characterization of the damage of a cement-based géomatériaux showed the efficacy of this approach. Under uniaxial loading, the evolution of the ultrasonic velocities and the attenuation of three types of wave have been detected as a result of damage within the material.We are interested in the second step the application of the ultrasonic system on the tomography (such as the velocities and attenuation) of damage during loading of materials. The study on some mortar specimens give good agreement between the obtained results and the observations, especially at failure , although the resolution is fairly coarse. The last part of this research is to model the damage of material by using a so-called up-scaling approach. A conceptual model is proposed for this type of material that allows to take into account two main damage mechanisms: crack in the cement matrix and debonding effect between the matrix and inclusions. Via a scheme of homogenization in two steps, the impact of such mechanisms on the evolution of velocities of the ultrasonic waves has been elucidated. The comparison of numerical predictions with experimental results allows validating the model.
|
1035 |
Ultraschallgestütze Bohrloch-Biopsien bei intraaxialen Hirnpathologien / Ultrasound-guided Burr-Hole Biopsies of Intraaxial Brain PathologiesAllouch, Hassan 16 August 2018 (has links)
No description available.
|
1036 |
Estratégia intervencionista versus conservadora no manejo dos acessos vasculares para hemodiálise / Interventional versus conservative strategy in the maintenance of the vascular access for hemodialysisScaffaro, Leandro Armani January 2007 (has links)
Introdução: A hemodiálise (HD) requer um acesso vascular funcionante para sua realização. A fístula arteriovenosa nativa (FAV) constitui-se no acesso ideal para essa prática, com menores índices de morbidade e trombose e melhor qualidade de vida. A estenose da FAV é a maior causa de trombose e perda do acesso vascular. A monitorização continuada dos acessos através de diferentes métodos pode reduzir a incidência de trombose da FAV, conforme indicado por estudos com controle histórico e não-randomizados. Objetivos: Avaliar se uma estratégia intervencionista através de ecografia com Doppler (ED), angiografia digital (AD) e angioplastia (ATP) reduz a incidência de trombose e necessidade do uso de cateter em veia central temporário (CVC) em relação ao manejo conservador em pacientes com FAV em programa de HD. Métodos: Estudo prospectivo randomizado controlado de 108 pacientes e 111 FAV em programa de HD durante 11 meses. No grupo controle, foram realizadas mensurações quinzenais de parâmetros hemodinâmicos durante sessões de HD. No grupo intervenção, além da mensuração dos parâmetros hemodinâmicos, foi realizada ED a cada três meses, seguido de AD em casos de disfunção do acesso, definida pela ocorrência de pelo menos 1 dos seguintes critérios: redução do frêmito da FAV, aumento das pressões venosas, pobre fluxo arterial ou formação de hematoma ou edema no membro superior recorrentes durante HD, e/ ou pela presença de estenose vascular maior que 50% e/ou um fluxo estimado inferior à 500ml/min na ED. Em estenoses angiográficas superiores a 50% foi realizada ATP. Os desfechos avaliados foram trombose e necessidade de implantação de CVC, bem como desfecho composto, dado pela associação dos desfechos referidos. Resultados: Foram randomizadas 58 FAV para o grupo controle e 53 FAV para o grupo intervenção. Não foram observadas diferenças significativas entre os grupos em relação aos dados demográficos, comorbidades e características do acesso. O tempo médio de seguimento foi de 7,5 meses. No grupo intervenção, foram realizadas 97 ED, com média de 1,83 exame por paciente. Foram indicadas 14 AD, sendo que um paciente não compareceu ao estudo. Foi evidenciada trombose da FAV em 4 casos, e estenose não-significativa em 1. Estenose significativa foi observada em 8 pacientes, sendo então realizada ATP nesses casos. Não houve diferença significativa entre os grupos quanto à incidência de trombose (24,1% vs 17,0% p=ns). A estratégia intervencionista determinou redução significativa na incidência de necessidade de CVC (25,9% vs 7,5%, p=0,021), e na incidência do desfecho composto (44,8% vs 20,8%, p=0,033). Conclusões: A estratégia intervencionista no manejo das FAV promoveu uma redução significativa da necessidade de CVC e do desfecho composto de trombose e CVC. / Background: Hemodialysis (HD) requires a functioning vascular access in appropriate conditions. Native arteriovenous fistulae (NAF) provide the ideal access for that practice. Stenosis of the NAF is the highest cause of thrombosis and loss of the HD vascular access. The continuous monitorization of the NAF through different methods reduce the incidence of thrombosis according to non-randomized studies with historical control. Objective: To evaluate an interventionist strategy through the follow up of the NAF with Color Flow Doppler ultrasound (US), digital angiography and transluminal angioplasty (ATP), when suitable, to reduce the thrombosis and need for the use of a temporary central vein catheter (CVC) rates in relation to the conservative strategy. Methods: A prospective randomized controlled study of 108 patients and 111 permanent vascular access in an HD program. In the control group, assesment of the hemodynamic parameters of the vascular access were performed every fiftheen days. In the intervention group , besides the assesment of the hemodynamic parameters, was submitted to US every three months, as well as with angiography in cases that presented criteria for dysfunction of the access, defined by the occurrence of at least 1 of the following: reduction of the thrill; increase of the vein pressure during HD sessions; impossibility of obtaining a flow of 300 ml/min during HD; recurring hematoma or edema formation and/or the presence of larger vascular stenoses than 50% or a flow lower than 500ml/min at the US. The patients that presented angiographic evidence of hemodymically significant stenoses were submitted to ATP. The primary outcomes were need for temporary CVC during the follow up, FAV thrombosis and composite outcome. The outcomes were compared between the groups at the end of a 11 months period of follow-up. Results: Fifht eight FAV were randomized to control group and 53 FAV to interventional group. No significant differences were observed between the groups in relation to the demographic data, comorbidities and characteristics of the access. The NAF studied were followed up for a mean time of 7,5 months. In the interventional group, 97 US were performed, with an average of 1,83 exam per patient. A total of 14 digital angiography were required, and evidenced thrombosis in 4 patients and nonsignificant stenosis in 1. Significant stenosis was observed in 8 patients, and ATP was performed in those cases. No statistically significant difference was observed between the groups in thrombosis rates 24,1% vs 17,0%, p=ns). The interventional strategy showed statistically significant redution in the incidence of the need for placement of CVC (25,9% vs 7,5%, p=0,021). The differences in the composite outcome was statistically significant (44,8% vs 20,8%, p=0,033). Conclusions : The interventional strategy promoted a significant reduction rates for the need of placement of central vein catheter and of the combined outcome in the studied sample, showing benefits in patients with FAV in hemodialysis program.
|
1037 |
Avaliação da lubrificação de rolamentos de motores elétricos por ultrassom / Evaluation of electrical motor bearing lubrication using ultrasound techniqueWeidlich, Felipe January 2009 (has links)
A crescente utilização de técnicas de manutenção preditiva pela indústria exige cada vez mais o aprimoramento dos procedimentos capazes de fornecer informações sobre o estado de um equipamento. Torna-se imperativo, desta forma, não apenas saber quando um equipamento ou componente mecânico irá falhar, mas também, entender o comportamento deste, diante de diferentes regimes de operação. Dentre os procedimentos de análise preditiva existentes para máquinas rotativas, a análise de vibração é um dos mais utilizados e está presente em grande parte das principais indústrias do país. Muito importante na detecção de vazamentos em tubulações industriais, o técnica de detecção de ruído ultrassônico é, entretanto, ainda pouco explorada para avaliação de falhas em componentes mecânicos. Utilizou-se uma metodologia experimental que permitiu avaliar dois motores elétricos por seis horas ininterruptas. Durante este período, variou-se a quantidade de graxa lubrificante aplicada nos respectivos mancais de rolamento e adquiriram-se respostas a estas variações com acelerômetros vibracionais, sensores de ruído ultrassônico e com um pirômetro ótico. Os resultados mostraram que não existe uma correlação entre as técnicas de análise de vibração e detecção de ruído ultrassônico para os motores testados no experimento. Além disso, foi possível definir quais eram as quantidades ótimas de graxa lubrificante para cada mancal de rolamento. Pôde-se concluir que a técnica de detecção de ruído ultrassônico se mostrou robusta na definição destas quantidades e também na determinação dos intervalos de relubrificação para cada rolamento. / The crescent utilization by Brazilian industry of predictive maintenance techniques demands, from predictive procedures, more capability for supplying information on the state of equipment. It becomes extremely important not just to know when a machine is going to fail, but also, to understand how it will be, considering several different conditions. Among the existent analysis procedures for rotating machines, the vibration analysis is the most usual, being nowadays, largely used in national industries. Very important for detecting leakage problems on industrial piping, the ultrasound analysis is still not applied to check mechanical components. It was used an experimental methodology which allowed to analyze two electrical motors for six hours. During this period, the quantity of grease applied on the rolling bearings was changed and new responses were acquired using vibration accelerometers, ultrasound sensors and a optical pyrometer. The results showed that there is not a correlation between vibration analysis and ultrasound detection technique for those electrical motors. Furthermore, it was possible to define the ideal quantities of grease for each rolling bearing. It was concluded that the ultrasound detection technique is robust for the definition of these quantities and also in determining the lubrication intervals for them.
|
1038 |
Obtenção de biodiesel via rota etílica auxiliado por ondas ultrassônicasBrito, Jeane Quelle Alves January 2011 (has links)
67 f. / Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2013-04-11T17:32:00Z
No. of bitstreams: 1
DISSERTACAO jeane quelle brito.pdf: 1136596 bytes, checksum: 8c3ba147541551b34feda989ad933110 (MD5) / Approved for entry into archive by Ana Hilda Fonseca(anahilda@ufba.br) on 2013-05-10T18:05:25Z (GMT) No. of bitstreams: 1
DISSERTACAO jeane quelle brito.pdf: 1136596 bytes, checksum: 8c3ba147541551b34feda989ad933110 (MD5) / Made available in DSpace on 2013-05-10T18:05:25Z (GMT). No. of bitstreams: 1
DISSERTACAO jeane quelle brito.pdf: 1136596 bytes, checksum: 8c3ba147541551b34feda989ad933110 (MD5)
Previous issue date: 2011 / A produção de biodiesel já é uma realidade no mundo, no entanto devido aos custos da produção, ainda não é um combustível economicamente competitivo. Nesse sentido, estudos de processos alternativos para a obtenção de biodiesel através da reação de transesterificação têm sido estudados com o objetivo de aumento de rendimento, redução do tempo de reação, diminuição do consumo de reagentes e diminuição de impactos ambientais. Esses estudos incluem o uso de irradiação ultrassônica, e a viabilização do emprego do etanol como insumo. A menor reatividade do álcool etílico em relação ao metanol torna a reação de transesterificação mais lenta, além de serem necessárias maiores temperaturas e excesso de álcool. A viabilização técnica do uso do etanol na produção do biodiesel pode contribuir de maneira efetiva na obtenção de biodiesel de fontes 100% renováveis e sustentável, considerando a produção consolidada de etanol no Brasil. A transesterificação para obtenção do biodiesel que ocorre entre o triacilglicerídeo e o álcool acontece na região de interface entre esses dois reagentes, uma vez que os mesmos são pouco miscíveis. O uso do ultrassom em processos químicos favorece tanto a transferência de massa, como também a própria reação, oferecendo assim reações com menor tempo, menor quantidade de reagentes e condições físicas mais brandas. O presente trabalho teve como objetivo estudar a utilização da irradiação ultrassônica como uma alternativa para superação das dificuldades encontradas para produção biodiesel utilizando a rota etílica. Para realização dos experimentos reacionais utilizou-se um processador ultrassônico de 750 watts equipado com sonda de titânio. Os experimentos foram conduzidos na presença de 250 g de óleo de soja (OS) e de óleo residual (OR), sem aquecimento externo e sob agitação mecânica constante. Foi realizado também um planejamento experimental fatorial de 2 níveis e 3 fatores (23), onde foram estabelecidos valores mínimos (-) e máximos (+) para estudo da influência dos fatores (I) razão óleo/etanol, (II) quantidade de catalisador e (III) tempo de sonicação na produção do biodiesel. Através dos resultados obtidos, foi possível mostrar que com o auxílio da irradiação do ultrassom é possível se obter biodiesel com qualidade adequada utilizando álcool etílico como insumo em tempos reacionais bastantes curtos. O uso de ultrassom mostrou ser uma alternativa promissora, uma vez que permitiu o uso de condições reacionais brandas de temperatura, sem utilização de grande excesso de etanol e obtenção de boas taxas de conversão. / Salvador
|
1039 |
Ultrassom 3D power doppler no diagnóstico precoce de pré-eclâmpsiaMoreira Neto, Raul January 2015 (has links)
Objetivo - Comparar índices 3D Power Doppler (PD3D) da circulação úteroplacentária (UPC) no primeiro e segundo trimestre em pacientes que desenvolveram pré-eclâmpsia (PE) e aquelas que não fizeram e testar a hipótese de que os parâmetros da vascularização e intensidade de fluxo da placenta, tal como determinado por PD3D, são diferentes em gestações normais em comparação com pré-eclâmpsia. Método - Foi realizado um estudo observacional prospectivo usando PD3D para avaliar a perfusão da placenta em 96 gestantes que fizeram o exame ecográfico de rotina entre 11 e 14 semanas. O índice vascular (VI), o índice de fluxo (FI) e o índice de fluxo vascular (VFI) por histograma Doppler tridimensional foram calculados. Todas pacientes repetiram o exame entre 16 e 20 semanas. Após o nascimento as pacientes foram classificadas como normais ou com pré-eclâmpsia. Resultados - Os índices vasculares placentários incluindo VI, FI e VFI foram significativamente menores em placentas com PE em comparação com os controles no exame realizado no segundo trimestre (p <0,001). Não houve diferença estatística nas pacientes examinadas no primeiro trimestre. Conclusão - Nossos resultados sugerem que a avaliação de índices vasculares placentários com Power Doppler 3D no segundo trimestre tem o potencial para detectar as mulheres em risco para o desenvolvimento posterior de PE. / Objective - To compare 3D power Doppler indices (3DPD) of utero-placental circulation (UPC) in the first and second quarter in patients who developed preeclampsia and those who did not and to test the hypothesis that the parameters of vascularization and placenta flow intensity, as determined by three-dimensional ultrasound (3D) are different in normal pregnancies compared with preeclampsia. Methods - A prospective observational study using 3D power Doppler was performed to evaluate the placental perfusion in 96 pregnant women who came to do the ultrasound routine between 11 and 14 weeks. The placental vascular index (VI), flow index (FI), blood vessels and blood flow index (VFI) by three-dimensional Doppler histogram were calculated. All patients repeated the exam between 16 and 20 weeks. The outcome was scored as normal or preeclamptic. Results - The placental vascular indices including VI, FI and VFI were significantly lower in preeclamptic placentas compared with controls in the study performed in the second trimester (p <0.001). There was no statistical difference in the patients examined in the first trimester. Conclusion - Our findings suggest that 3D-Power Doppler assessment of placental vascular indices in the second trimester has the potential to detect women at risk for subsequent development of PE.
|
1040 |
Análise da espessura muscular através de imagens de ultrassonografia em crianças e adolescentes com fibrose císticaSouza, Rodrigo Pereira de January 2015 (has links)
Objetivos: Comparar a espessura muscular e a espessura da gordura subcutânea entre crianças e adolescentes com fibrose cística e sujeitos hígidos utilizando imagens de ultrassonografia. Métodos: Estudo transversal em crianças e adolescentes com diagnóstico de FC, com idade entre 6 e 18 anos, em acompanhamento ambulatorial no Hospital São Lucas da PUCRS e controles hígidos.Os sujeitos que apresentavam exacerbação pulmonar e incapacidade de realizar os procedimentos do estudo foram excluídos. Os participantes submeteram-se a ultrassonografia para verificar a espessura muscular e a espessura da gordura subcutânea das regiões do tríceps, quadríceps e gastrocnêmio, medidas antropométricas e avaliação das dobras cutâneas (adipometria). As estimativas dos componentes da composição corporal foram fracionados em quatro: massa muscular, massa de gordura, massa óssea e residual e foram analisados conforme equações matemáticas e fórmulas específicas previamente validadas. Os indivíduos com FC realizaram a avaliação da função pulmonar por meio da espirometria. A comparação entre os grupos estudados foi realizada através do teste de McNemar, t de Student para amostras pareadas e teste de Wilcoxon. As correlações foram avaliadas através do teste de correlação de Pearson. Resultados: Foram incluídos 84 participantes, sendo 39 com FC e 45 controles, média de idade de 12,94 anos e 61,9 % do sexo masculino. Houve diferença significativa na comparação entre as características demográficas e antropométricas, entre os dois grupos avaliados, para raça (p<0,01), IPAQ (p<0,01) e escore Z do IMC (p<0,03). Na comparação entre os componentes da composição corporal entre os grupos, houve diferença significativa no peso de gordura (p<0,02) e no peso ósseo (p<0,01). Não houve diferenças significativas entre o peso muscular e o peso residual. Houve correlação da ultrassonografia muscular do tríceps e a massa magra (r=0,253; p<0,05) e entre a ultrassonografia muscular do quadríceps com o escore Z do IMC (r=0,25; p<0,05). Não houve correlações significativas na ultrassonografia da gordura subcutânea do tríceps, do quadríceps e do gastrocnêmio entre os grupos avaliados. Ao correlacionar os dois métodos de avaliação de gordura corporal, obtiveram-se correlações significativas (p<0,01) moderadas e positivas, variando de r=0,472 até r=0,681. No grupo dos pacientes com fibrose cística, a espessura muscular do tríceps medida pela ultrassonografia correlacionou-se com o escore Z da caminhada de seis minutos (r=-0,376). Além disso, a espessura muscular do quadríceps medida pela ultrassonografia correlacionou-se com a massa magra (r=0,424; p<0,01), capacidade vital forçada (CVF) (r=0,468; p<0,01), percentual do previsto da CVF (r=0,338; p<0,05), escore Z da CVF (r=0,336; p<0,05) e com o volume expiratório forçado no primeiro segundo (VEF1) (r=0,393; p<0,05). Conclusão: A avaliação da espessura muscular de pacientes com FC por ultrassonografia foi semelhante aos indivíduos controles, da mesma maneira que a avaliação da massa magra obtida com a adipometria e medidas de perímetros. Na avaliação da espessura de gordura subcutânea, houve correlação moderada entre a adipometria e a ultrassonografia. A ultrassonografiaapresenta potencial de aplicabilidade para diagnóstico nutricionaledeveser melhor avaliada, a fim de validara sua utilização emavaliações de rotina. / Objectives: To compare muscle and subcutaneous fat thickness between children and adolescents with cystic fibrosis and healthy subjects using ultrasound images. Methods: Cross-sectional study in children and adolescents diagnosed with CF, aged 6 to 18 years, followed at Hospital São Lucas PUCRS, and healthy controls (HC). Subjects who had a pulmonary exacerbation or inability to perform the study procedures were excluded. The participants underwent ultrasound to check muscle and subcutaneous fat thickness at the triceps, quadriceps and gastronomies regions, anthropometric measurements and evaluation of skin folds. Component estimation of body composition were divided into four: muscle mass, fat mass, bone and residual mass and were analyzed according to mathematical equations and previously validated specific equations. CF individual sunder went pulmonary function assessment by spirometry. Comparison between groups was performed using Mc Nemar test, Student's t test for paired samples and Wilcoxon test. Correlations were assessed using Pearson's correlation test. Results: We included 84 participants, 39 with CF and 45 healthy controls, mean age was 12.94 years and 61.9% were male. There was a significant difference between demographic and anthropometric characteristics between the two groups, for race (p<0.01) IPAQ (p<0.01) and BMI Z score (p<0.03). Comparing the components of body composition between the groups there was no significant difference in fat weight (p<0.02) and bone weight (p<0.01). There were no significant differences between muscle weight and the residual weight. There was a correlation of ultrasound triceps muscle and lean body mass (r=0.253; p<0.05) and between the quadriceps muscle ultrasound with the Z score of BMI (r=0.25; p<0.05). There were no significant correlations in ultrasound subcutaneous fat triceps, quadriceps and gastronomies between the groups. By correlating the two methods of assessing body fat, significant correlations (p<0.01) and moderate positive, ranging from r=0.472 to r= 0.681were found. In CF patients, muscular thickness of the triceps measured by ultrasonography correlated with walk test six minutes Z score (r= -0.376). Furthermore, quadriceps muscle thickness measured by ultrasonography correlated with body lean mass (r=0.424; p<0.01), forced vital capacity (FVC) (r=0.468; P<0.01) percentage of predicted FVC (r = 0.338; p <0.05), FVC Z score (r= 0.336; p<0.05) and forced expiratory volume in one second (FEV1) (r=0.393; p<0.05). Conclusion: Evaluation of muscle thickness in CF patients and HC by ultrasound rendered similar results in the same fashion as the assessment of lean body mass by skin fold and circumference measurements. In assessing subcutaneous fat thickness, there was moderate correlation between skin folds and ultrasound findings. Ultrasound evaluation shows an applicability potentiality for nutritional diagnosis and should be better evaluated in order to validate its use in routine clinical assessments.
|
Page generated in 0.3407 seconds