  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Commande non linéaire et stabilisation des systèmes de transmission VSC-HVDC

Mohamed Ramadan, Haitham Saad 15 March 2012 (has links) (PDF)
L'intégration des liaisons à courant continu dans les systèmes électriques permet d'accroitre les possibilités de pilotage des réseaux, ce qui permet d'en améliorer la sûreté et de raccorder de nouveaux moyens de production. Pour cela la technologie VSC-HVDC est de plus en plus plébiscitée pour interconnecter des réseaux non synchrones, raccorder des parcs éoliens offshore, ou contrôler le flux d'énergie notamment sur des longues distances au travers de liaisons sous-marines (liaison NorNed). Les travaux de cette thèse portent sur la modélisation, la commande non-linéaire et la stabilisation des systèmes VSC-HVDC, avec deux axes de travail. Le premier se focalise sur la conception et la synthèse des lois de commandes non-linéaires avancées basées sur des systèmes de structures variables (VSS). Ainsi, les commandes par modes glissants (SMC) et le suivi asymptotique de trajectoire des sorties (AOT) ont été proposées afin d'assurer un degré désiré de stabilité en utilisant des fonctions de Lyapunov convenables. Ensuite, la robustesse de ces commandes face à des perturbations et/ou incertitudes paramétriques a été étudiée. Le compromis nécessaire entre la robustesse et le comportement dynamique requis dépend du choix approprié des gains. Ces approches robustes, qui sont facile à mettre en œuvre, ont été appliquées avec succès afin d'atteindre des performances dynamiques élevées et un niveau raisonnable de stabilité vis-à-vis des diverses conditions anormales de fonctionnement, pour des longueurs différentes de liaison DC. Le deuxième vise à étudier l'influence de la commande du convertisseur VSC-HVDC sur l'amélioration de la performance dynamique du réseau de courant alternatif en cas d'oscillations. Après une modélisation analytique d'un système de référence constitué d'un groupe connecté à un convertisseur VSC-HVDC via un transformateur et une ligne, un contrôleur conventionnel simple PI est appliqué au niveau du convertisseur du système pour agir sur les oscillations rotoriques de la machine synchrone. Cette commande classique garantie une amélioration acceptable des performances dynamiques du système; surtout pour l'amortissement des oscillations de l'angle de puissance de la machine synchrone lors de défauts.
22

Linear Modeling of DFIGs and VSC-HVDC Systems / Linjär modellering av dubbelmatade asynkrongeneratorer och spänningsstyva HVDC-system

Cao, Weiran January 2015 (has links)
Recently, with growing application of wind power, the system based on the doubly fedinduction generator (DFIG) has become the one of the most popular concepts. Theproblem of connecting to the grid is also gradually revealed. As an effective solution toconnect offshore wind farm, VSC-HVDC line is the most suitable choice for stabilityreasons. However, there are possibilities that the converter of a VSC-HVDC link canadversely interact with the wind turbine and generate poorly damped sub-synchronousoscillations. Therefore, this master thesis will derive the linear model of a single DFIG aswell as the linear model of several DFIGs connecting to a VSC-HVDC link. For thelinearization method, the Jacobian transfer matrix modeling method will be explainedand adopted. The frequency response and time-domain response comparison betweenthe linear model and the identical system in PSCAD will be presented for validation. / Nyligen, med ökande tillämpning av vindkraft, det system som bygger på den dubbeltmatad induktion generator (DFIG) har blivit en av de mest populära begrepp. Problemetmed att ansluta till nätet är också gradvis avslöjas. Som en effektiv lösning för att anslutavindkraftpark är VSC -HVDC linje det lämpligaste valet av stabilitetsskäl. Det finns dockmöjligheter att omvandlaren en VSC-HVDC länk negativt kan interagera medvindturbinen och genererar dåligt dämpade under synkron svängningar. Därför kommerdetta examensarbete härleda den linjära modellen av en enda DFIG liksom den linjäramodellen av flera DFIGs ansluter till en VSC-HVDC -länk. För arise metoden kommerJacobian transfer matrix modelleringsmetodförklaras och antas. Jämförelse mellan denlinjära modellen och identiskt system i PSCAD frekvensgången och tidsdomänensvarkommer att presenteras för godkännande.
23

A Multichoice Control Strategy for a VSC-HVdc

Latorre, Hector F. January 2008 (has links)
Utilization of power electronics based controllable systems (or devices) in transmission systems has opened new opportunities for the power industry to optimize utilization of the existing transmission systems, and at the same time to keep high system reliability and security. As a member of these controllable systems, Voltage Source Converters-based High Voltage direct current (VSC-HVdc) systems have the ability to rapidly control the transmitted active power, and also to independently exchange reactive power with transmissions systems. Therefore, VSC-HVdcs with a suitable control scheme can offer an alternative means to enhance transient stability, to improve power oscillations damping, and to provide voltage support. An interesting application of this system is the analysis of a power system when a VSC-HVdc is connected in parallel with ac transmission lines. This thesis presents the derivation of control strategies to damp power oscillations, to enhance the transient stability and to provide voltage support for a VSC-HVdc. The thesis also formulates a multichoice control strategy and its application when the VSC-HVdc is connected in a synchronous system. The control strategy for enhancing transient stability is based on the theory of Control Lyapunov Function. The control strategy for increasing the damping is based on Linear Analysis. A very effective well known way to increase damping in the system is modulating the active power through the HVdc. However, besides the control of active power, the thesis explores an alternative way to mitigate power oscillations by controlling the reactive power. This condition might be very useful when the dc link in the VSC-HVdc system is out of service, but the converter stations are in operating conditions. A simple model of VSC-HVdc is considered in order to test the control strategy. The model represents the VSC-HVdc as an element in the power system that provides adequate interaction with other systems elements. The model is intended for analysis of power flows and electromechanical transients. It is then sufficient to consider the power frequency components of voltages and currents represented by phasors that vary with time during transients. The model is valid for symmetrical conditions, i.e. positive sequence phasors are used for the representation of the electrical state. / QC 20101117
24

Analyser av två VSC-HVDC-stationer genom långtidsmätningar med elkvalitetsmätare / Analysis of two VSC-HVDC stations through long-time measurements with power quality analyzers

Pettersson, Martin January 2018 (has links)
Gotland har länge präglats av mycket speciella lösningar och legat i framkant vad gäller ny teknik. Under ca 20 år har Gotland haft en VSC-HVDC-station som har stabiliserat spänningen i det gotländska nätet. HVDC Light har löst en del av de tekniska begränsningarna som hindrat utvecklingen av vindkraftverk. Anläggningen börjar lida mot slutet av sin tekniska livslängd och examensarbetet är ett första steg i utredningen för en eventuell ersättning. Med hjälp av elkvalitetsmätare kartlagdes prestanda och eventuella förbättringsområden. Den svenska stamnätsoperatören Svenska kraftnät har sedan 2016 haft en VSC-HVDC-station som använts för att utväxla energi till asynkrona systemet i Östeuropa. Svenska kraftnät har på senare tid velat utnyttja spänningsregleringsmöjligheterna och utreda mättekniska metoder. Elkvalitetsmätare placerades ut på lämpliga mätpunkter för att utreda anläggningens beteenden. ELSPEC G4500 elkvalitetsmätare installerades på Nordbalt och Gotlands HVDC Light för att mäta under sensommar till hösten 2017. Skillnader mellan CVT och IVT samt Rogowskispole och CT mättes. Valet av ELSPEC lämpade sig bra eftersom att inga triggningsvillkor behövdes som tillåter att man kan upptäcka små men viktiga avvikelser. Gotlands HVDC Light stabiliserar nätet främst mot spänningsdippar efter kortslutningar i 10 kV-elnätet och flimmer ifrån vindkraftsparkerna i ände 2. Märkeffekten för en uppdaterad anläggning kommer baseras på den kortslutningseffekt i 10 kV-nätet som kan utvecklas under anläggningens livstid. Spänningsregleringen ska baseras på en PI-regulator och ska kunna reglera fullt på 40 ms. Komponentspänningar kan användas för att ge reaktiv effekt på de faser som behöver det. Behovet mot flimmer ska baseras på en mätning i närmaste konsumtionscentrum, två mil från ände 2. Om behovet finns, ska en separat loop för flimmerkontroll som motverkar 1,5 Hz-komponenter implementeras utifrån en punkt ca 1,5 mil ifrån ände 2. Teknikvalet står mellan two-level generation 3 eller MMC, beroende på uppgradering eller ersättning. Många olika framtida scenarion påverkar HVDC Lights roll och oavsett, kommer mycket resurser behövas för Gotlands och HVDC Lights framtid. Det har observerats två beteenden på Nordbalt varav ena är långsam och det andra beteendet är snabbt. Det snabba beteendet uppstår när lågohmiga fel sker som också synkronmaskinerna tar hand om. Nordbalt kan hjälpa till för mindre spänningsvariationer om den varit snabbare likt beteendet vid lågohmiga fel. En stabilitetsbedömning behövs dock eftersom att snabbare beteende ökar risken för instabilitet. Eftersom att data mellan CVT och IVT skiljde sig mycket, upplystes mättekniska problem. Några lösningar diskuteras varav RCVT och PQSensor gås igenom grundligt. Alternativa lösningar som MoW och mobila enheter presenteras också vagt. Samtliga lösningar visade sig ha praktiska hinder, vilket försvårar genomförandet. Det uppmanas därför att man bör testa teknikerna i laborationsmiljö eftersom begränsat med studier gjorts på dessa samt att konkurrerande tillverkare uppger olika uppgifter. / Gotland has long been known for various special solutions and been on the leading edge regarding new technology. For the past 20 years Gotland has had a VSC-HVDC station that has stabilized the voltage in the Gotlandic grid. HVDC Light has solved some of the technical limitations that has hindered the growth of wind turbines. The station has almost reached the end of its technical lifespan and the thesis is a first step in the investigation for an eventual replacement. With power quality analyzers performance and improvements were investigated. The Swedish transmission system operator Svenska kraftnät have since 2016 had a VSCHVDC station that have been used to exchange energy to the asynchronous system in Eastern Europe. Svenska kraftnät has of lately wanted to take advantage of the voltage control capabilities and investigate measurement technologies. Power quality analyzers were installed on suitable connection points to investigate the behavior of the station. ELSPEC G4500 power quality analyzers were installed on Nordbalt’s and Gotland’s HVDC Light to measure during the late summer to fall of 2017. The differences between CVT and IVT, and Rogowski coil and CT were captured. The choice of ELSPEC suited well since no trigger conditions are needed which allows small but important errors to be discovered. Gotland’s HVDC Light stabilizes the grid mostly against voltage sags for faults in the 10 kVgrid and flicker from the wind farms in node 2. The rated power for an upgrade should be based on the 10 kV-grid short-circuit power to be developed during the station’s life span. The voltage control should be based on a PI-controller and should be able to transmit full power in 40 ms. Component voltages can be used to produce reactive power on the phases in need. The need against flicker should be based on measurements in the closest center of consumption, 2 miles from node 2. If it’s needed, a separate loop for flicker-control that prevents 1.5 Hz-components based on a point 1.5 mile from node 2 should be implemented. Depending on an upgrade or replacement, the topology can either be “two-level generation 3” or MMC. Many different future scenarios affect HVDC Light’s role and more resources will be required for Gotland’s and HVDC Light’s future. Two behaviors have been observed on Nordbalt where one is slow and the other behavior is fast. The fast behavior was only observed when low impedance faults occurs, that the synchronous generators also handles. Nordbalt can contribute to small voltage variations if it was faster, like the behavior for low impedance faults. A consideration in stability is needed since a faster behavior can lead to stability problems. Since the data between CVT and IVT differed a lot, metrology problems were discovered. Some solutions were discussed, of which RCVT and PQSensor was thoroughly reviewed. Alternative solutions like MoW and mobile units were also presented vaguely. All solutions showed practical difficulties, which complicates the implementation. It is therefore encouraged to test the technologies in a laboratory environment since few studies have been made on these and competing manufactures state different information.
25

Metodologia para mapeamento de zonas operacionais em sistemas de transmissão VSC-HVDC. / Methodology for mapping operational zones in VSC-HVDC transmission sytems.

Itiki, Rodney 31 January 2018 (has links)
Sistemas de transmissão de energia elétrica em corrente contínua e alta tensão baseados em tecnologia de conversores a fonte de tensão (VSC-HVDC), ao contrário de linhas de transmissão em corrente alternada, operam como elementos de controle de variáveis elétricas, podendo ser úteis na estabilidade do sistema de potência. Mas apesar desta vantagem, sistemas VSC-HVDC possuem limitações no desempenho estável, o que enseja o desenvolvimento de uma metodologia para mapeamento de suas zonas de operação estável e possíveis regiões de instabilidade. Inicialmente estudou-se os detalhes da tecnologia VSC-HVDC tais como o funcionamento da eletrônica de potência e estratégias de controle utilizadas. Em seguida, investigou-se os modelos de geradores síncronos para interconexão com o lado CA das estações conversoras do VSC-HVDC. E, finalmente, aplicou-se a tecnologia VSC-HVDC sobre um modelo de sistema de potência com uma estação conversora localizada em um porto offshore e uma outra no continente, próxima à rede de alta tensão em corrente alternada. Simulações e análise deste sistema foram executadas considerando várias condições operacionais. O gráfico de potência gerada e consumida, obtido pela aplicação da metodologia, apresenta grande potencial de uso prático como por exemplo sua implementação na interface homem-máquina da estação de operação do porto offshore, provendo informação em tempo real de alto nível ao operador do sistema elétrico do porto offshore e consequentemente aumentando sua consciência situacional quanto a proximidade dos limites de instabilidade. / High voltage direct current power transmission systems based on voltage source converters (VSC-HVDC), as opposed to alternating current ones, operates as elements of control of electrical variables, being useful for stability of power system. Besides this advantage, VSC-HVDC systems have limitations in stable performance, which instigates the development of a methodology for mapping its operational zones of stability and possible regions of instability. The author initially studied the details of the VSC-HVDC technology such as the power electronic principles and the control strategies used on this research. Subsequently, the author investigated synchronous generator models for interconnection on the AC side of the VSC-HVDC converter stations. Finally, the author applied the VSC-HVDC technology on a model of power system with two converter stations, one located on an offshore port and the other on the shore, next to an alternating current high voltage power grid. Simulations and analysis of this system were carried out considering various operational conditions. The graphic of generated and consumed power on offshore port, obtained by the application of the methodology for mapping operational zones, presents a great potential of being implemented in the man-machine interface of an operation workstation, thus providing high level online information for the operator of the offshore port electrical system and consequently improving its situational awareness of the proximity to instability limits.
26

Metodologia para mapeamento de zonas operacionais em sistemas de transmissão VSC-HVDC. / Methodology for mapping operational zones in VSC-HVDC transmission sytems.

Rodney Itiki 31 January 2018 (has links)
Sistemas de transmissão de energia elétrica em corrente contínua e alta tensão baseados em tecnologia de conversores a fonte de tensão (VSC-HVDC), ao contrário de linhas de transmissão em corrente alternada, operam como elementos de controle de variáveis elétricas, podendo ser úteis na estabilidade do sistema de potência. Mas apesar desta vantagem, sistemas VSC-HVDC possuem limitações no desempenho estável, o que enseja o desenvolvimento de uma metodologia para mapeamento de suas zonas de operação estável e possíveis regiões de instabilidade. Inicialmente estudou-se os detalhes da tecnologia VSC-HVDC tais como o funcionamento da eletrônica de potência e estratégias de controle utilizadas. Em seguida, investigou-se os modelos de geradores síncronos para interconexão com o lado CA das estações conversoras do VSC-HVDC. E, finalmente, aplicou-se a tecnologia VSC-HVDC sobre um modelo de sistema de potência com uma estação conversora localizada em um porto offshore e uma outra no continente, próxima à rede de alta tensão em corrente alternada. Simulações e análise deste sistema foram executadas considerando várias condições operacionais. O gráfico de potência gerada e consumida, obtido pela aplicação da metodologia, apresenta grande potencial de uso prático como por exemplo sua implementação na interface homem-máquina da estação de operação do porto offshore, provendo informação em tempo real de alto nível ao operador do sistema elétrico do porto offshore e consequentemente aumentando sua consciência situacional quanto a proximidade dos limites de instabilidade. / High voltage direct current power transmission systems based on voltage source converters (VSC-HVDC), as opposed to alternating current ones, operates as elements of control of electrical variables, being useful for stability of power system. Besides this advantage, VSC-HVDC systems have limitations in stable performance, which instigates the development of a methodology for mapping its operational zones of stability and possible regions of instability. The author initially studied the details of the VSC-HVDC technology such as the power electronic principles and the control strategies used on this research. Subsequently, the author investigated synchronous generator models for interconnection on the AC side of the VSC-HVDC converter stations. Finally, the author applied the VSC-HVDC technology on a model of power system with two converter stations, one located on an offshore port and the other on the shore, next to an alternating current high voltage power grid. Simulations and analysis of this system were carried out considering various operational conditions. The graphic of generated and consumed power on offshore port, obtained by the application of the methodology for mapping operational zones, presents a great potential of being implemented in the man-machine interface of an operation workstation, thus providing high level online information for the operator of the offshore port electrical system and consequently improving its situational awareness of the proximity to instability limits.
27

High voltage direct current (HVDC) in applications for distributed independent power providers (IPP)

Giraneza, Martial January 2013 (has links)
Thesis submitted in fulfillment of the requirements for the degree Master of Technology: Electrical Engineering in the Faculty of Engineering at the Cape Peninsula University of Technology 2013 / The development of power electronics did remove most of technical limitations that high voltage direct current (HVDC) used to have. HVDC, now, is mostly used for the transmission of bulk power over long distances and for the interconnection of asynchronous grid. Along with the development of the HVDC, the growth of power demand also increased beyond the utilities capacities. Besides the on-going increasing of power demand, the reforms in electricity market have led to the liberalization and the incorporation of Independent power providers in power system operation. Regulations and rules have been established by regulating authority for grid integration of Independent power providers. With the expected increase of penetration level of those new independent power providers, result of economic reason and actual green energy trend, best method of integration of those new power plants are required. In this research HVDC technology, namely VSC-HVDC is used as interface for connecting independent power providers units to the grid. VSC-HVDC has various advantages such as short-circuit contribution and independent control of active and reactive power. VSC-HVDC advantages are used for a safe integration of IPPs and make them participate to grid stabilization. MATLAB/Simulink simulations of different grid connected, through VSC-HVDC system, IPPs technologies models are performed. For each IPP technology model, system model performances are studied and dynamics responses during the disturbance are analyzed in MATLAB/ Simulink program. The simulation results show that the model satisfy the standard imposed by the regulating authority in terms of power quality and grid support. Also the results show the effect of the VSC-HVDC in preventing faults propagation from grid to integrated IPPs units.