• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 2
  • 1
  • 1
  • Tagged with
  • 7
  • 7
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

The affective experience of moral decision making

Creel, Laura Haley, Stadler, Holly A. January 2006 (has links) (PDF)
Dissertation (Ph.D.)--Auburn University, 2006. / Abstract. Vita. Includes bibliographic references (p.176-188).
2

Mitteilungen des URZ 1/2003

Ziegler,, Richter,, Riedel,, Hille, 10 March 2003 (has links)
Mitteilungen des URZ 1/2003
3

Quantificação da carga viral do HIV-1 no líquor : comparação entre os ensaios Abbott m2000rt e COBAS TaqMan v2.0

Luz, Ana Júlia Bretanha January 2017 (has links)
Introdução A preocupação crescente com as possíveis consequências da replicação viral no sistema nervoso central mostra a necessidade da detecção do HIV no compartimento cerebral. O teste de PCR em tempo real desenvolvido pela Abbott, o Abbott m2000 RealTime HIV-1 (m2000rt), quantifica a carga viral do HIV em amostras de sangue com um procedimento efetivo e de baixo custo no nosso país, por isso é adotado como método padrão pelo Ministério da Saúde, mas não é utilizado em amostras de líquor. O ensaio produzido pela Roche, o COBAS TaqMan HIV-1, version 2 (COBAS v2.0), é o método de PCR em tempo real que tem sido amplamente utilizado para detectar a carga viral do HIV no compartimento cerebral. No entanto, esse método ainda não foi validado para esse propósito e seu custo pode ser uma limitação em diversas regiões com baixos recursos. Objetivos Considerando que não há uma metodologia padronizada para essa situação específica (detecção do HIV no líquor), nós conduzimos esse estudo a fim comparar os desempenhos dos testes m2000rt e COBAS v2.0, na tentativa de propôr um método alternativo e com baixos custos ao mais utilizado nesse contexto (COBAS v2.0). Métodos O estudo foi realizado no período de maio de 2015 a julho de 2016. O cálculo do tamanho da amostra foi baseado em dados de um estudo piloto que revelaram ser necessário um número mínimo de 37 amostras, para detectar uma diferença de 0,20 log10 na carga viral, com um coeficiente de correlação de 0,979 e um poder de 90%. Essa equação permitiria uma perda de 10%. As amostras de líquor foram coletadas consecutivamente a partir de 37 pacientes HIV positivos atendidos no Hospital de Clínicas de Porto Alegre/RS. Os métodos foram processados de acordo com o proposto pelo fabricante para utilização com amostras de plasma. Pequenas modificações foram necessárias no teste em estudo (m2000rt) para neutralizar qualquer diferença metodológica e evitar vieses de mensuração: o congelamento das amostras foi realizado a -20ºC até o momento da análise. O ensaio COBAS v2.0 foi utilizado como referência, uma vez que é o método mais utilizado. Foram realizadas análises quantitativas com resultados que estavam dentro da faixa linear em ambos os métodos (n = 18). Para tornar os métodos comparáveis, adotou-se o limite de detecção do ensaio m2000rt para ambos (40 cp/mL ou 1,60 log10 cp/mL). Os resultados abaixo do limite de detecção foram apresentados como uma variável categórica, uma vez que não são quantificáveis. O coeficiente de correlação de Pearson foi utilizado para comparar os métodos. A normalidade das variáveis foi então resumida calculando o viés estimado pela diferença média "đ " e o desvio padrão das diferenças realizadas pelo teste t para amostras pareadas. Com base na falta de normalidade dos métodos, o grau de concordância dos resultados das cargas virais de HIV foi analisado pelo índice Kappa. Esse estudo foi aprovado pelo comitê de ética do Hospital de Clínicas de Porto Alegre (RS)/ Brasil, registrado na Plataforma Brasil como sendo CAAE: 35072214.7.0000.532. Conclusão Em conclusão, o teste m2000rt que foi modificado para este ensaio mostrou boa concordância e correlação com o teste mais utilizado nesse contexto e pode ser considerado um método alternativo com resultados semelhantes ao COBAS v2.0 e baixos custos na quantificação da carga viral do HIV no líquor. Sugerimos, principalmente em locais onde este método está prontamente disponível com uma relação custo-benefício aceitável, que o exame m2000rt deva ser realizado. / Introduction Growing concern about possible consequences of viral replication in the central nervous system shows the need for HIV detection in the cerebral compartment. The real time PCR test developed by Abbott, Abbott RealTime m2000 HIV-1 (m2000rt) quantifies HIV viral load in blood samples effectively and with low costs Brazil. It is the standard method by the Brazilian Ministry of Health, but it has never been utilized to measure HIV in cerebrospinal fluid samples. The assay produced by Roche, COBAS TaqMan HIV-1, version 2 (COBAS v2.0) is the real-time PCR method that has been widely used to detect HIV viral load in cerebral compartment. However, this method has not yet been validated for this purpose and its cost may be a limitation in several regions in the world with low resources. Objective Taking under consideration that there was no standard methodology for this specific situation (detecting HIV in cerebrospinal fluid), we conducted this study to compare the performances of the m2000rt and COBAS v2.0 assays, to propose an alternative and low-cost method to more used in this context (COBAS v2.0). Methods The study was conducted from May 2015 to July 2016. The sample size calculation was based on data from a pilot trial that revealed that a minimum of 37 samples would be needed to detect a difference of 0.20 log10 in viral load, with a correlation coefficient of 0.979 and a 90% power. This equation would allow a 10% lost. CSF samples were collected consecutively from 37 HIV-positive patients seen at Hospital de Clínicas, Porto Alegre, RS. Methods were processed according to proposed by the manufacturer for utilization with plasma samples. Small modifications were necessary in the study test (m2000rt) to neutralize any methodological differences, thus avoiding measurement bias: the freezing of samples was carried out at -20ºC until the moment of the analysis. The COBAS v2.0 test was used as a reference since it is the most commonly used method. Quantitative analyzes were performed with results that were within the linear range in both methods (n=18). To make the methods comparable, the detection limit of the m2000rt assay for both (40 cp/mL or 1.60 log10 cp/mL) was adopted. The results below the limit of detection were presented as a categorical variable, since they are not quantifiable. The Pearson correlation coefficient was used to compare methods. The normality of the variables was then summarized calculating the estimated bias by the mean difference "đ" and standard deviation of the differences performed by t test for paired samples. Based on the lack of normality of the methods, the degree of agreement of the HIV viral load results was analyzed by the Kappa index. This study was approved by the Hospital de Clínicas of Porto Alegre (southern Brazil) Ethics Review Board, registered in the Brazil Platform as CAAE: 35072214.7.0000.532. Conclusion In conclusion, the m2000rt test that was modified for this trial showed good agreement and correlation with the most used test in this context and can be considered an alternative method with similar results to COBAS v2.0 and low costs in the HIV viral load quantification in cerebrospinal fluid. We suggest, especially in places where this method is readily available with an acceptable cost-benefit ratio, that the m2000rt exam should be performed.
4

Quantificação da carga viral do HIV-1 no líquor : comparação entre os ensaios Abbott m2000rt e COBAS TaqMan v2.0

Luz, Ana Júlia Bretanha January 2017 (has links)
Introdução A preocupação crescente com as possíveis consequências da replicação viral no sistema nervoso central mostra a necessidade da detecção do HIV no compartimento cerebral. O teste de PCR em tempo real desenvolvido pela Abbott, o Abbott m2000 RealTime HIV-1 (m2000rt), quantifica a carga viral do HIV em amostras de sangue com um procedimento efetivo e de baixo custo no nosso país, por isso é adotado como método padrão pelo Ministério da Saúde, mas não é utilizado em amostras de líquor. O ensaio produzido pela Roche, o COBAS TaqMan HIV-1, version 2 (COBAS v2.0), é o método de PCR em tempo real que tem sido amplamente utilizado para detectar a carga viral do HIV no compartimento cerebral. No entanto, esse método ainda não foi validado para esse propósito e seu custo pode ser uma limitação em diversas regiões com baixos recursos. Objetivos Considerando que não há uma metodologia padronizada para essa situação específica (detecção do HIV no líquor), nós conduzimos esse estudo a fim comparar os desempenhos dos testes m2000rt e COBAS v2.0, na tentativa de propôr um método alternativo e com baixos custos ao mais utilizado nesse contexto (COBAS v2.0). Métodos O estudo foi realizado no período de maio de 2015 a julho de 2016. O cálculo do tamanho da amostra foi baseado em dados de um estudo piloto que revelaram ser necessário um número mínimo de 37 amostras, para detectar uma diferença de 0,20 log10 na carga viral, com um coeficiente de correlação de 0,979 e um poder de 90%. Essa equação permitiria uma perda de 10%. As amostras de líquor foram coletadas consecutivamente a partir de 37 pacientes HIV positivos atendidos no Hospital de Clínicas de Porto Alegre/RS. Os métodos foram processados de acordo com o proposto pelo fabricante para utilização com amostras de plasma. Pequenas modificações foram necessárias no teste em estudo (m2000rt) para neutralizar qualquer diferença metodológica e evitar vieses de mensuração: o congelamento das amostras foi realizado a -20ºC até o momento da análise. O ensaio COBAS v2.0 foi utilizado como referência, uma vez que é o método mais utilizado. Foram realizadas análises quantitativas com resultados que estavam dentro da faixa linear em ambos os métodos (n = 18). Para tornar os métodos comparáveis, adotou-se o limite de detecção do ensaio m2000rt para ambos (40 cp/mL ou 1,60 log10 cp/mL). Os resultados abaixo do limite de detecção foram apresentados como uma variável categórica, uma vez que não são quantificáveis. O coeficiente de correlação de Pearson foi utilizado para comparar os métodos. A normalidade das variáveis foi então resumida calculando o viés estimado pela diferença média "đ " e o desvio padrão das diferenças realizadas pelo teste t para amostras pareadas. Com base na falta de normalidade dos métodos, o grau de concordância dos resultados das cargas virais de HIV foi analisado pelo índice Kappa. Esse estudo foi aprovado pelo comitê de ética do Hospital de Clínicas de Porto Alegre (RS)/ Brasil, registrado na Plataforma Brasil como sendo CAAE: 35072214.7.0000.532. Conclusão Em conclusão, o teste m2000rt que foi modificado para este ensaio mostrou boa concordância e correlação com o teste mais utilizado nesse contexto e pode ser considerado um método alternativo com resultados semelhantes ao COBAS v2.0 e baixos custos na quantificação da carga viral do HIV no líquor. Sugerimos, principalmente em locais onde este método está prontamente disponível com uma relação custo-benefício aceitável, que o exame m2000rt deva ser realizado. / Introduction Growing concern about possible consequences of viral replication in the central nervous system shows the need for HIV detection in the cerebral compartment. The real time PCR test developed by Abbott, Abbott RealTime m2000 HIV-1 (m2000rt) quantifies HIV viral load in blood samples effectively and with low costs Brazil. It is the standard method by the Brazilian Ministry of Health, but it has never been utilized to measure HIV in cerebrospinal fluid samples. The assay produced by Roche, COBAS TaqMan HIV-1, version 2 (COBAS v2.0) is the real-time PCR method that has been widely used to detect HIV viral load in cerebral compartment. However, this method has not yet been validated for this purpose and its cost may be a limitation in several regions in the world with low resources. Objective Taking under consideration that there was no standard methodology for this specific situation (detecting HIV in cerebrospinal fluid), we conducted this study to compare the performances of the m2000rt and COBAS v2.0 assays, to propose an alternative and low-cost method to more used in this context (COBAS v2.0). Methods The study was conducted from May 2015 to July 2016. The sample size calculation was based on data from a pilot trial that revealed that a minimum of 37 samples would be needed to detect a difference of 0.20 log10 in viral load, with a correlation coefficient of 0.979 and a 90% power. This equation would allow a 10% lost. CSF samples were collected consecutively from 37 HIV-positive patients seen at Hospital de Clínicas, Porto Alegre, RS. Methods were processed according to proposed by the manufacturer for utilization with plasma samples. Small modifications were necessary in the study test (m2000rt) to neutralize any methodological differences, thus avoiding measurement bias: the freezing of samples was carried out at -20ºC until the moment of the analysis. The COBAS v2.0 test was used as a reference since it is the most commonly used method. Quantitative analyzes were performed with results that were within the linear range in both methods (n=18). To make the methods comparable, the detection limit of the m2000rt assay for both (40 cp/mL or 1.60 log10 cp/mL) was adopted. The results below the limit of detection were presented as a categorical variable, since they are not quantifiable. The Pearson correlation coefficient was used to compare methods. The normality of the variables was then summarized calculating the estimated bias by the mean difference "đ" and standard deviation of the differences performed by t test for paired samples. Based on the lack of normality of the methods, the degree of agreement of the HIV viral load results was analyzed by the Kappa index. This study was approved by the Hospital de Clínicas of Porto Alegre (southern Brazil) Ethics Review Board, registered in the Brazil Platform as CAAE: 35072214.7.0000.532. Conclusion In conclusion, the m2000rt test that was modified for this trial showed good agreement and correlation with the most used test in this context and can be considered an alternative method with similar results to COBAS v2.0 and low costs in the HIV viral load quantification in cerebrospinal fluid. We suggest, especially in places where this method is readily available with an acceptable cost-benefit ratio, that the m2000rt exam should be performed.
5

Quantificação da carga viral do HIV-1 no líquor : comparação entre os ensaios Abbott m2000rt e COBAS TaqMan v2.0

Luz, Ana Júlia Bretanha January 2017 (has links)
Introdução A preocupação crescente com as possíveis consequências da replicação viral no sistema nervoso central mostra a necessidade da detecção do HIV no compartimento cerebral. O teste de PCR em tempo real desenvolvido pela Abbott, o Abbott m2000 RealTime HIV-1 (m2000rt), quantifica a carga viral do HIV em amostras de sangue com um procedimento efetivo e de baixo custo no nosso país, por isso é adotado como método padrão pelo Ministério da Saúde, mas não é utilizado em amostras de líquor. O ensaio produzido pela Roche, o COBAS TaqMan HIV-1, version 2 (COBAS v2.0), é o método de PCR em tempo real que tem sido amplamente utilizado para detectar a carga viral do HIV no compartimento cerebral. No entanto, esse método ainda não foi validado para esse propósito e seu custo pode ser uma limitação em diversas regiões com baixos recursos. Objetivos Considerando que não há uma metodologia padronizada para essa situação específica (detecção do HIV no líquor), nós conduzimos esse estudo a fim comparar os desempenhos dos testes m2000rt e COBAS v2.0, na tentativa de propôr um método alternativo e com baixos custos ao mais utilizado nesse contexto (COBAS v2.0). Métodos O estudo foi realizado no período de maio de 2015 a julho de 2016. O cálculo do tamanho da amostra foi baseado em dados de um estudo piloto que revelaram ser necessário um número mínimo de 37 amostras, para detectar uma diferença de 0,20 log10 na carga viral, com um coeficiente de correlação de 0,979 e um poder de 90%. Essa equação permitiria uma perda de 10%. As amostras de líquor foram coletadas consecutivamente a partir de 37 pacientes HIV positivos atendidos no Hospital de Clínicas de Porto Alegre/RS. Os métodos foram processados de acordo com o proposto pelo fabricante para utilização com amostras de plasma. Pequenas modificações foram necessárias no teste em estudo (m2000rt) para neutralizar qualquer diferença metodológica e evitar vieses de mensuração: o congelamento das amostras foi realizado a -20ºC até o momento da análise. O ensaio COBAS v2.0 foi utilizado como referência, uma vez que é o método mais utilizado. Foram realizadas análises quantitativas com resultados que estavam dentro da faixa linear em ambos os métodos (n = 18). Para tornar os métodos comparáveis, adotou-se o limite de detecção do ensaio m2000rt para ambos (40 cp/mL ou 1,60 log10 cp/mL). Os resultados abaixo do limite de detecção foram apresentados como uma variável categórica, uma vez que não são quantificáveis. O coeficiente de correlação de Pearson foi utilizado para comparar os métodos. A normalidade das variáveis foi então resumida calculando o viés estimado pela diferença média "đ " e o desvio padrão das diferenças realizadas pelo teste t para amostras pareadas. Com base na falta de normalidade dos métodos, o grau de concordância dos resultados das cargas virais de HIV foi analisado pelo índice Kappa. Esse estudo foi aprovado pelo comitê de ética do Hospital de Clínicas de Porto Alegre (RS)/ Brasil, registrado na Plataforma Brasil como sendo CAAE: 35072214.7.0000.532. Conclusão Em conclusão, o teste m2000rt que foi modificado para este ensaio mostrou boa concordância e correlação com o teste mais utilizado nesse contexto e pode ser considerado um método alternativo com resultados semelhantes ao COBAS v2.0 e baixos custos na quantificação da carga viral do HIV no líquor. Sugerimos, principalmente em locais onde este método está prontamente disponível com uma relação custo-benefício aceitável, que o exame m2000rt deva ser realizado. / Introduction Growing concern about possible consequences of viral replication in the central nervous system shows the need for HIV detection in the cerebral compartment. The real time PCR test developed by Abbott, Abbott RealTime m2000 HIV-1 (m2000rt) quantifies HIV viral load in blood samples effectively and with low costs Brazil. It is the standard method by the Brazilian Ministry of Health, but it has never been utilized to measure HIV in cerebrospinal fluid samples. The assay produced by Roche, COBAS TaqMan HIV-1, version 2 (COBAS v2.0) is the real-time PCR method that has been widely used to detect HIV viral load in cerebral compartment. However, this method has not yet been validated for this purpose and its cost may be a limitation in several regions in the world with low resources. Objective Taking under consideration that there was no standard methodology for this specific situation (detecting HIV in cerebrospinal fluid), we conducted this study to compare the performances of the m2000rt and COBAS v2.0 assays, to propose an alternative and low-cost method to more used in this context (COBAS v2.0). Methods The study was conducted from May 2015 to July 2016. The sample size calculation was based on data from a pilot trial that revealed that a minimum of 37 samples would be needed to detect a difference of 0.20 log10 in viral load, with a correlation coefficient of 0.979 and a 90% power. This equation would allow a 10% lost. CSF samples were collected consecutively from 37 HIV-positive patients seen at Hospital de Clínicas, Porto Alegre, RS. Methods were processed according to proposed by the manufacturer for utilization with plasma samples. Small modifications were necessary in the study test (m2000rt) to neutralize any methodological differences, thus avoiding measurement bias: the freezing of samples was carried out at -20ºC until the moment of the analysis. The COBAS v2.0 test was used as a reference since it is the most commonly used method. Quantitative analyzes were performed with results that were within the linear range in both methods (n=18). To make the methods comparable, the detection limit of the m2000rt assay for both (40 cp/mL or 1.60 log10 cp/mL) was adopted. The results below the limit of detection were presented as a categorical variable, since they are not quantifiable. The Pearson correlation coefficient was used to compare methods. The normality of the variables was then summarized calculating the estimated bias by the mean difference "đ" and standard deviation of the differences performed by t test for paired samples. Based on the lack of normality of the methods, the degree of agreement of the HIV viral load results was analyzed by the Kappa index. This study was approved by the Hospital de Clínicas of Porto Alegre (southern Brazil) Ethics Review Board, registered in the Brazil Platform as CAAE: 35072214.7.0000.532. Conclusion In conclusion, the m2000rt test that was modified for this trial showed good agreement and correlation with the most used test in this context and can be considered an alternative method with similar results to COBAS v2.0 and low costs in the HIV viral load quantification in cerebrospinal fluid. We suggest, especially in places where this method is readily available with an acceptable cost-benefit ratio, that the m2000rt exam should be performed.
6

Mitteilungen des URZ 1/2003

Ziegler, Richter, Riedel, Hille 10 March 2003 (has links)
Mitteilungen des URZ 1/2003
7

Minimal important change of the Short-Form 6-Dimension version 2 in a Quebec population sample

Sowmithran, Arthi 05 1900 (has links)
Contexte : La quantification des subjectivités associées aux états de santé peut fournir des informations sur la qualité de vie reliée à la santé (QVRS). Pour rendre compte de ces subjectivités dans la mesure de la QVRS, on utilise des instruments d'utilité multi attribut comme le Short-Form 6-Dimension Version 2 (SF-6Dv2). Ces instruments permettent de décrire les états de santé, de dériver les utilités correspondantes et d’estimer le changement minimal important (CMI) qui est spécifique à différents groupes de populations, afin de tirer des inférences sur l'état de santé de la population. Le CMI est ici un point central correspondant à la variation minimale considérée comme importante dans la QVRS par les répondants. Le but de cette étude est de déceler le seuil de CMI du SF-6Dv2 pour un échantillon de la communauté québécoise. Méthodes : Une enquête en ligne auprès de la population générale adulte du Québec a été menée entre mars 2020 et septembre 2021 pendant six cycles ou intervalles de temps. Le questionnaire SF-6Dv2 a été administré à chaque cycle, ainsi qu’une question sur la perception d’un changement dans l’état de santé (‘Global Rating of Change’) à partir du cycle 2. Les scores d’utilité en santé ont été calculés pour chaque participant à l’aide de deux ensembles de valeurs de référence (‘value set’), soit pour le Royaume-Uni et le Québec. Actuellement il n'existe pas de value set canadien pour le SF-6Dv2 et le value set québécois n'était disponible qu'en 2023. Une analyse des données avec des méthodes basées sur la distribution et l’ancrage a été effectuée pour déterminer les valeurs de CMI. Résultats : En considérant que les participants avec les réponses 2 ou 4 à la question du ‘Global Rating of Change’ ont connu un changement minimal dans leur état de santé, le CMI calculé avec la pondération du Royaume-Uni était de 0,030 (IC 95% [0,023 ; 0,038], valeur p < 0,001) et pour le Québec de 0,029 (IC 95% [0,023 ; 0,036], valeur p < 0,001) pour le SF-6Dv2. Les méthodes basées sur la distribution ont permis d'obtenir une réponse moyenne standardisée (SRM) de 0,134 et 0,152 avec les ensembles de valeurs du Royaume-Uni et du Québec, respectivement. La taille de l'effet et le demi-écart-type ont également été calculés (0,106 et 0,143 avec Royaume-Uni) (0,115 et 0,127 avec Québec). Conclusion : Le CMI calculé valide la bonne sensibilité (réactivité) du SF-6Dv2 dans la population générale du Québec et fournit une estimation du seuil minimalement important pour les participants. Le CMI permet d’interpréter la QVRS calculée et l’utiliser pour comprendre si la santé s'est significativement améliorée ou détériorée du point de vue des répondants. Les études d’évaluation des technologies de la santé et de prise de décision deviennent ainsi plus valables, car elles tiennent compte de la subjectivité individuelle ressentie et associée à un état de santé particulier, en plus des résultats cliniques objectifs. / Background: Quantifying subjectivities associated with health states can offer information on the health-related quality of life (HRQoL). To account for such subjectivities on HRQoL we use multi attribute utility instruments such as the Short-Form 6-Dimension version 2 (SF-6Dv2). They allow health state description, derive corresponding health utilities, and provide an estimate of minimal important change (MIC) which is specific to different population groups, for inferences on population health. MIC is a central point corresponding to the minimal change in HRQoL that is considered important by the participant. The aim of this study was to find the minimal important change of a generic preference-based instrument, the SF-6Dv2 for a Quebec community sample. Methods: An online survey of the adult general population in Quebec was conducted between March 2020 and September 2021 over six time intervals. SF-6Dv2 was administered at each cycle and a global rating of change question was also administered in the follow-up cycles starting from cycle 2. Health utilities were calculated for each participant using a United Kingdom (UK) based value set (preference weights) and a Quebec value set. At present a Canadian value set is not available for SF-6Dv2 and the Quebec value set was developed in 2023. Data analysis was performed with both anchor and distribution-based methods to ascertain the MIC values. Results: Considering the participants who chose 2 or 4 in the Global Rating of Change question as having experienced a minimal change in health state, the MIC calculated with UK value set was 0.03 (95% CI [0.023 ; 0.038], p-value < 0.001) and with Quebec value set 0.0293 (95% CI [0,023 ; 0,036], p-value < 0,001) for SF-6Dv2. Distribution-based methods yielded a standardized response mean (SRM) of 0.134 and 0.152 with the UK and Quebec value sets, respectively. Effect size and half a standard deviation were 0.106, 0.143 for UK and 0.115, 0.127 for Quebec, respectively. Conclusion: The MIC calculated hence validates SF-6Dv2’s responsiveness in the general population and estimates a utility score minimally important to the participants. This MIC enables HRQoL calculated from such instruments to be appropriately interpreted and to understand if health has improved or deteriorated from the participant’s perspective. Further rendering health technology evaluation and decision-making studies more valid by accounting for the subjectivity felt and associated with a particular health state, apart from the objective clinical results.

Page generated in 0.0579 seconds