• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 853
  • 13
  • 12
  • 12
  • 12
  • 12
  • 6
  • 5
  • 4
  • 4
  • 3
  • 2
  • 1
  • Tagged with
  • 879
  • 485
  • 195
  • 181
  • 180
  • 134
  • 129
  • 117
  • 115
  • 105
  • 102
  • 101
  • 99
  • 89
  • 82
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
551

Processamento e caracterização de compósitos híbridos fibra/metal.

Rogério de Almeida Silva 14 December 2006 (has links)
Este trabalho apresenta a preparação e a caracterização de materiais compósitos híbridos, chamados de Laminados Fibra-Metal (LFM), obtidos pela combinação de pré-impregnados (prepregs) de uso aeronáutico e de lâminas de alumínio adequadamente preparadas para garantir a adesão entre os componentes. Hoje, em nível mundial, a obtenção e o emprego adequado de LFM são temas atuais de estudo na área de materiais para o setor aeronáutico. Como contribuições deste estudo têm-se: (a) a preparação de LFM pela utilização de prepregs em forma tecidos, em substituição aos reforços unidirecionais, obtendo-se o Laminado de Fibra de Vidro Metal (LFVM) e o Laminado de Fibra de Carbono Metal (LFCM); (b) o tratamento superficial da lâmina de alumínio 2024 T3 Bare, pelo uso de um processo de anodização à base de ácido sulfúrico-bórico-oxálico (SBOA), e (c) o estudo do melhor procedimento para proteger regiões de corte e furação dos LMF preparados. O tratamento superficial proposto visa eliminar o Cr(VI) do tratamento convencional de anodização à base de ácido crômico (CAA), classificado como altamente poluente para o meio ambiente, tóxico e carcinogênico. Os LFM preparados pelos dois processos (SBOA e CAA) são avaliados por ensaios mecânicos (resistências à tração, impacto, cisalhamento, compressão e fadiga), de resistência à corrosão e de resistência ao fogo. Os resultados da caracterização dos LFM obtidos com alumínio tratado por SBOA mostram-se equivalentes ou superiores aos obtidos com o tratamento CAA, validando o tratamento alternativo (SBOA) proposto. Finalmente, apresenta-se uma discussão crítica que envolve as vantagens e desvantagens dos LFM processados.
552

Aplicação da simulação na análise da capacidade de processos relacionados à indústria vidreira.

Paulo Luiz Ferreira 12 July 2006 (has links)
O presente trabalho descreve os resultados de uma investigação sobre a modelagem e a análise via software de simulação, de problemas relacionados ao dimensionamento de equipamentos e determinação da capacidade de processamento em uma linha de produção de vidros laminados. Neste contexto utilizam-se métodos e técnicas que auxiliam na modelagem simplificada do sistema real sem, entretanto perder a "validação" dos dados obtidos após simulação. O escopo dos resultados deste trabalho compreende o processo de desenvolvimento do modelo de simulação propriamente dito e o desempenho deste modelo após execução do mesmo. O processo de montagem de um modelo é tão mais trabalhoso quanto mais complexo é o sistema. Neste trabalho foi montado um modelo com boa capacidade e qualidade de representação do sistema real, sendo que através de testes estatísticos de validação se comprovou este fato. Dados valiosos sobre o funcionamento do sistema foram obtidos de forma muito mais rápida e menos cara, do que se comparado à tentativa de obtenção destes dados, no sistema real. O uso de técnicas de experimentação produziu resultados os quais foram analisados estatisticamente, fornecendo subsídios para o entendimento do funcionamento do sistema, e possibilitando a obtenção dos objetivos específicos deste trabalho de forma clara. As conclusões finais apresentadas neste trabalho, principalmente às que se referem ao dimensionamento de filas em processo, não seriam passiveis de obtenção por outra técnica se não a simulação, dado a complexidade do processo de produção.
553

Estudo da cura e sorção de água em compósitos estruturais de fibra de vidro-epóxi por espectroscopia de luminescência e de infravermelho.

Rita de Cássia Mendonça Sales 08 May 2009 (has links)
Os compósitos de alto desempenho têm sido largamente utilizados na fabricação de peças estruturais primárias e secundárias de aeronaves, foguetes e vários tipos de artefatos aeroespaciais. Esta ampla utilização está relacionada às excelentes propriedades mecânicas desses materiais, além de sua massa específica menor em relação às ligas metálicas comumente utilizadas pela indústria aeroespacial. As propriedades mecânicas dos laminados de materiais compostos dependem fortemente de vários fatores tais como: estrutura de reforço, fração em volume da fibra, número de vazios, interação entre a fibra e a resina termofixa, grau de cura da resina e teor de água no material. O objetivo deste trabalho é estudar do processo de cura e a influência de umidade em materiais pré-impregnados e laminados de fibra de vidro - resina epoxídica por meio de espectroscopia de luminescência em modo estacionário. Utilizaram-se os métodos de luminescência intrínseca e extrínseca. O primeiro método é baseado na emissão da matriz polimérica e o segundo está relacionado à emissão do 9-ácido antróico (9-AA). Os estudos de espectroscopia de luminescência foram acompanhados por análise gravimétrica, espectroscopia de absorção no infravermelho médio com transformada de Fourier (FT-IR), microscopia eletrônica de varredura (SEM), análise termogravimétrica (TG) e calorimetria exploratória diferencial (DSC). O estudo do processo de cura foi conduzido pela comparação de resultados obtidos das técnicas de luminescência intrínseca e de espectroscopia de absorção no infravermelho próximo com transformada de Fourier (FT-NIR). A luminescência extrínseca do 9-AA foi utilizada para acompanhar a redução do volume livre durante o tratamento térmico. A técnica de FT-IR também foi usada para caracterizar as resinas epoxídicas contidas nos prepregs F-155 e F-161. Prepregs contendo ou não 9-AA foram tratados termicamente a 121 C (F-155) e a 177 C (F-161) por 1100 minutos a uma velocidade de aquecimento de 2 C/min. Os resultados obtidos indicam que a reação de cura pode ser monitorada pela análise das mudanças espectrais das bandas de emissão e de excitação do prepreg e do 9-AA. Para a análise da influência de umidade as amostras foram curadas e submetidas em ambientes com umidade controlada a 60 e 80 C, por períodos de tempo de 1, 7, 15, 30, 60 e 90 dias. Pode-se verificar que a diminuição do máximo de emissão das amostras está diretamente relacionada com a entrada de umidade no material.
554

Avaliação da resistência estática e em fadiga de compósitos de fibra de carbono/epóxi e fibra de vidro/epóxi sob cisalhamento modo iosipescu.

Vanderlei de Oliveira Gonçalves 09 December 2010 (has links)
Os materiais compósitos têm sido cada vez mais utilizados principalmente na indústria aeroespacial devido à sua característica de baixa massa específica aliada à alta resistência mecânica, tanto estática quanto em fadiga. Estruturas aeronáuticas e aeroespaciais sofrem, durante operação em serviço, esforços mecânicos de tração, compressão, flexão e cisalhamento. Muitas vezes esses esforços ocorrem de maneira combinada. Dentre esses esforços, o de cisalhamento é, sem dúvida, o mais complexo de avaliação devido à heterogeneidade, anisotropia e baixa resistência, que pode causar a falha prematura da estrutura. Dentre os métodos de ensaio para avaliação de propriedades em cisalhamento, o método Iosipescu, pelo fato de ser simples e eficaz para a obtenção da resistência (?) e do módulo em cisalhamento interlaminar ou no plano, tem recebido aceitação pela comunidade científica. O presente trabalho propõe-se a caracterizar as propriedades estáticas, resistência e módulo em cisalhamento, e avaliar a vida em fadiga, por meio do método Iosipescu, para uma resina epóxi e para compósitos com matriz em resina epóxi reforçados com tecido de fibras de vidro e tecido de fibras de carbono. A partir de resultados estáticos de cisalhamento no plano foram realizados ensaios de fadiga e obtidas curvas S-N com duas razões de tensão diferentes, R=0,1 e 0,5, frequência de 12 Hz, carregamento cíclico constante na forma senoidal e limite máximo de 120 000 ciclos. Os valores de ?12 e G12 obtidos estaticamente e em fadiga são comparados entre os materiais ensaiados. A resina epóxi sem reforço apresenta o menor módulo e limite de fadiga, seguida pelos compósitos orientados a 0/90 e, finalmente, pelos compósitos orientados a 45. Observa-se também que, em todos os materiais, a vida em fadiga é maior para R=0,5, devido principalmente ao comportamento viscoelástico da resina epóxi.
555

Avaliação do desempenho térmico de brises transparentes: ensaio em células-teste / Evaluation thermal performance of transparent solar protections: measurements in test-cells

Miana, Anna Christina 09 December 2005 (has links)
O objetivo desta pesquisa foi avaliar o desempenho térmico de brises transparentes, por meio de medidas em células-teste construídas em escala 1:1, na cidade de Campinas, São Paulo. Trata-se de um estudo que faz avaliação comparativa das temperaturas internas e superficiais dos brises e do vidro da janela em seis células-teste, quatro delas protegidas com brises transparentes horizontais e verticais combinados, constituídos por vidros, outra protegida com brise-soleil metálico horizontal e uma sem dispositivo de proteção solar, sendo esta considerada de referência. Foram selecionados quatro tipos de vidro com diferentes características ópticas: vidro float comum incolor, vidro impresso mini-boreal, vidro float comum azul e vidro refletivo metalizado a vácuo prata médio. Foi possível concluir que os brises de vidro refletivo prata, float azul e impresso possuem um desempenho térmico similar entre si e ao brise metálico estudado, e que o brise de vidro float incolor não apresenta um resultado de desempenho térmico satisfatório. Com relação aos procedimentos de medidas de campo, foram verificadas as modificações necessárias, para trabalhos futuros que tenham o mesmo objetivo dessa pesquisa, ou similares a esse. Além da avaliação do desempenho térmico, foi também iniciada uma avaliação do desempenho luminoso dos brises. Por meio das medidas dos níveis de iluminação natural dentro das células-teste constatou-se que o brise de vidro impresso apresentou um ótimo desempenho luminoso e que o brise de vidro refletivo prata reduziu significativamente a iluminância dentro da célula-teste, obtendo um desempenho luminoso inferior até mesmo ao brise metálico / This research intended to evaluate thermal performance of transparent solar protections using measurements in full scale test cells, located in the city of Campinas, São Paulo, Brazil. Surface (window and shading device) and internal air temperatures were compared for six test cells. One of them was unprotected, for reference purposes, another was obstructed with a metallic shading device and the other four had transparent glass horizontal and vertical shades installed. Four different types of glass with different optical properties were selected: float clear glass, mini-boreal printed glass, float blue glass and metallic silver reflective glass. The results of the thermal appraisal showed that silver reflective glass, float blue and printed glass shadings achieved similar performance, not very different to the ones obtained for the metallic shading device. Therefore the float clear glass shading did not attain a satisfactory result. The field measurements procedures were also evaluated and test cells characteristics problems were identified, in order to suggest changes for future research in this area. This research began to evaluate light performance of the same solar protections. For light performance evaluation were measured the daylight in the center of each test cell and outside. It was concluded that printed glass shadings presented very good results and silver reflective glass reduced the daylight inside the test cell
556

Estudo do efeito de compostos de selênio em vidros soda-cal-sílica. / Study of the effect of selenium compounds in soda-lime-silica glasses.

Cavalcante, Renata Andrade Kobayashi 21 June 2013 (has links)
O selênio é utilizado como elemento colorante ou descolorante na indústria vidreira. Sua característica altamente volátil durante a fusão do vidro, com perdas de até 80%, tem sido uma questão discutida já há muito tempo. Assim, alternativas têm sido buscadas na tentativa de aumentar o rendimento do selênio. Utilizar o princípio da microencapsulação do selênio através da obtenção de vidros pelo método sol-gel apresenta-se como uma possibilidade para novos estudos. O método sol-gel permite obter vidros de alta pureza utilizando recursos mais simples que em uma fusão convencional. Este trabalho apresenta um estudo do rendimento do selênio em duas composições de vidros sodo-cálcicos. Para tanto, foram utilizadas diferentes fontes de selênio (Se0, ZnSeO3, Na2SeO3). Uma proposta desta pesquisa foi obter uma nova fonte de selênio através da síntese de um material rico em sílica pelo método sol-gel, o qual contenha selênio em sua formulação. Este material é utilizado como uma alternativa de inserção de selênio visando o aumento de seu rendimento durante a fusão, considerando-se o princípio da microencapsulação. As amostras vítreas contendo selênio apresentaram coloração rosa. Os resultados de análise química mostram que a incorporação de selênio foi maior para as amostras com maior concentração de álcalis. Uma das amostras contendo um dos materiais sintetizados pelo método sol-gel apresentou a menor perda de selênio (34%) dentre todas, indicando que o método proposto foi eficiente para a redução da volatilização deste elemento. Os ensaios de absorção óptica apresentam três bandas de absorção: 380 nm (Fe3+), 500 nm (Se0 / Se2-) e 720 nm (Fe2+). As amostras obtidas por sol-gel são amorfas, adquiriram uma forte coloração avermelhada com o tempo e os resultados obtidos nos ensaios de caracterização indicaram uma potencial aplicação deste material como sensor de umidade. / Selenium is used as a colorant and discolorant element in the glass industry. Its highly volatile characteristic during the glass melting, which causes losses around 80%, has been discussed for a long time. Meanwhile, alternatives have been searched to increase the yield of selenium. Microencapsulation of the selenium by sol-gel processing may be considered for new studies. This work presents an investigation, in laboratory scale, of the selenium yield in two model soda-lime glass compositions. Different sources of selenium (Se0, ZnSeO3, Na2SeO3) were used, which were incorporated into a silica rich material, containing the selenium source, by sol-gel method. The glass samples were obtained by melting the raw-materials at 1350°C in high alumina crucibles, and showed different grades of pink coloration. Chemical analysis results showed that the incorporation of selenium was higher in the glass containing higher concentration of alkaline elements. In terms of selenium source, the best yield (lowest loss of selenium) was 34 wt%, obtained with SG3 (synthesized material by sol-gel method) as the selenium source. The optical absorption curves presented three main absorption bands: 380 nm (Fe3+), 500 nm (Se0/Se2-) and 720 nm (Fe2+). The samples obtained by sol-gel were amorphous, acquired a strong reddish coloration with time, and indicated potential characteristics for application as a humidity sensor.
557

Fabricação de microestruturas poliméricas opticamente ativas integradas com nanofibras de vidro / Fabrication of optically active polymeric microstructures integrated with glass nanofibers

Gomes, Vinicius Tribuzi Rodrigues Pinheiro 19 April 2013 (has links)
Este trabalho demonstra o uso da fotopolimerização via absorção de dois fótons na produção de microestruturas dopadas com compostos orgânicos e nanopartículas de Au. A capacidade de produção de microestruturas com propriedades variadas é extremamente relevante, pois viabiliza o desenvolvimento de uma nova geração de dispositivos ópticos. Além disso, realizamos a conexão entre as microestruturas fabricadas e fontes de excitação, por meio de nanofibras de vidro. A integração entre essas estruturas, e destas com meios externos de excitação e detecção, é um passo essencial para o desenvolvimento de microcircuitos fotônicos, que podem representar uma nova revolução tecnológica, a exemplo do que foram os microcircuitos eletrônicos. Exploramos as possibilidades de dopagem da resina usando: (i) um composto fluorescente, (ii) um composto com birrefringência fotoinduzida e (iii) nanopartículas de ouro. Microestruturas contendo Rodamina B apresentaram boa integridade estrutural e fluorescência, tendo sido usadas para demonstrar a conexão dos microelementos com meios externos de excitação. Através de nanofibras e de micromanipuladores, comprovamos a capacidade de excitação seletiva de microestruturas através do guiamento da luz de um laser de Ar+. Estruturas birrefringentes foram obtidas pela dopagem com o azopolímero HEMA-DR13. Montamos um aparato que permite a observação da dinâmica de indução de birrefringência nas microestruturas, o qual representa um grande passo na caracterização deste tipo de microelementos. Com base nesse estudo, foi possível alcançar uma fração de birrefringência residual nas microestruturas de 35%. Por fim, propomos um método para a dopagem de microestruturas poliméricas com nanopartículas de ouro. Por se tratar de um método de dopagem indireta, ele evita interferências das nanopartículas no processo de microfabricação. Dessa forma, este trabalho abre possibilidades para a fabricação de microdispositivos funcionais com diversas propriedades especiais, bem como a integração desses microdispositivos em circuitos fotônicos. / This work demonstrates the use of two-photon photopolymerization in the fabrication of microstructures doped with organic compounds and gold nanoparticles. The ability to produce microstructures with different properties is extremely relevant, because it opens the possibility for the development of a new generation of optical devices. Besides, we have accomplished the connection between fabricated microstructures and excitation sources by means of silica nanowires. The connection among structures and with external means of detection and excitation is an essential step towards the development of new technological breakthrough in photonic microcircuits. We have explored the resin doping possibilities by using: (i) a fluorescent compound, (ii) a photoinduced birefringent compound and (iii) gold nanoparticles. Rhodamine B doped microstructures present good structural integrity and fluorescence, and were able to demonstrate the connection of microelements with external means of excitation. Through the use of nanofiber tapers and micromanipulators, we have shown the selective excitation capability of this method by guiding Ar+ laser light onto one single microstructure. Birefringent samples were obtained by doping the resin with the azopolymer HEMA-DR13. We have assembled an apparatus that allows observing the photoinduced birefringence dynamics, which represents a great step towards a better characterization of these kinds of microelements. Based on this study we were able to achieve a residual birefringence fraction of 35% in microscopic samples. Finally, we have proposed a new method for the doping of polymeric microstructures with gold nanoparticles. Because it is an indirect doping technique, it prevents gold nanoparticles from interfering with the microfabrication process. Thus, the work presented here paves the way for the fabrication of functional microdevices with a wide range of special properties, as well as for the connection of these microstructures for photonic microcircuit.
558

LONGEVIDADE DE RESTAURAÇÕES ATRAUMÁTICAS EM PRÉ- ESCOLARES REALIZADAS COM DIFERENTES TIPOS DE CIMENTO DE IONÔMEROS DE VIDRO / Survival of art restorations in pre-school children using different glass ionomer cements

Cançado, Naiana Mello 18 February 2016 (has links)
Made available in DSpace on 2017-07-24T19:22:00Z (GMT). No. of bitstreams: 1 Naiana Mello.pdf: 2483986 bytes, checksum: 7acbee807e93d7e15753a45ec65dd51b (MD5) Previous issue date: 2016-02-18 / This clinical trial main objective was to evaluate the survival of atraumatic restorative treatment restorations (ARTs) in 3-5 years old children using four different types of glass ionomer cements (GIC). After sample size calculation an amount of 301 ARTs were placed in 110 children at their school, according to the following treatment groups: GC Gold Label - GC (n=72), Maxxion R – FGM (n=76), Ketac Molar Easymix – 3M ESPE (n=77) and Vitrofil LC – DFL (n=76). The ARTs were evaluated clinically at 3, 6, 9 and 12 months after placement, by one trained and blinded examiner, according to the ART evaluation criteria. The collected data were analyzed using Kaplan-Meier survival test and Log-rank test setting the significance level at 5%. After 12 months, the success rates of the ARTs were 68.4%, regardless the type of cavity or GIC brand used. When the type of the cavity was considered, single surface cavities achieved success rates of 78,4%, 76,3%, 67,3% and 75% for GC Gold Label, Ketac Molar Easymix, Maxxion R and Vitrofil, respectively. Multiple surface cavities, the success rates were 77,3% for GC Gold Label, 57,5% for Ketac Molar Easymix, 52,6% for Maxxion R and 50% for Vitrofil. No statistical differences were detected among GIC brands (p>0.05). However, there was significant differences when comparing the types of cavities. The multiple surface cavities present a greater chance to fail, irrespective of the GIC used (p=0.05). After 12 months, the mean survival period was 9.9 months (95% CI: 9.5-10.3), regardless the restorative material used. No interferences of the independent variable age and ICDAS scores were detected. It’s concluded that the survival of ART restorations was not affected by the brand of the GIC used and that single surface cavities showed higher survival rates than multiple surface ones, regardless the GIC used. / O objetivo desse ensaio clínico foi avaliar a longevidade de restaurações atraumáticas (RAs) realizadas em ambiente escolar em crianças de 3 a 5 anos de idade com quatro diferentes cimentos de ionômero de vidro (CIV). Após cálculo amostral um total de 301 RAs foram realizadas em 110 crianças divididas em quatro grupos, GC Gold Label - GC (n=72), Maxxion R – FGM (n=76), Ketac Molar Easymix – 3M ESPE (n=77) e Vitrofil LC – DFL (n=76). As restaurações foram avaliadas aos 3, 6, 9 e 12 meses de acordo com critérios ART por um avaliador treinado, calibrado e cego em relação ao grupo de estudo. Os dados coletados foram submetidos ao teste de sobrevivência de Kaplan-Meier com teste de Log-rank para análise da longevidade com nível de significância de 5%. O índice de sucesso das restaurações, independente do material ou tipo de cavidade, foi de 68.4% ao final dos doze meses. Ao se considerar o tipo de cavidade, para as cavidades simples, os níveis de sucesso foram de 78,4%, 76,3%, 67,3% e 75% para o GC Gold Label, Ketac Molar Easymix, Maxxion R e Vitrofil, respectivamente. Já para as cavidades compostas, o sucesso foi de 77,3% para o GC Gold Label, 57,5% para o Ketac Molar Easymix, 52,6% para Maxxion R e 50% para Vitrofil. Não houve diferença estatística entre os materiais (p>0.05). Após 12 meses de acompanhamento, a sobrevivência média das restaurações foi de 9.9 meses (95% IC: 9,5 – 10,3), sem diferença entre os materiais. Conclui-se que o tipo de cimento de ionômero de vidro utilizado não influencia na longevidade das restaurações atraumáticas e cavidades simples apresentam maior longevidade que as complexas, independente do tipo de cimento de ionômero de vidro utilizado.
559

EFEITO DA DOLOMITA E DA CASEÍNA FOSFOPEPTÍDEA FOSFATO DE CÁLCIO AMORFO NAS PROPRIEDADES QUÍMICO-MECÂNICAS DA DENTINA DECÍDUA DESMINERALIZADA

Dias, Gisele Fernandes 26 August 2016 (has links)
Made available in DSpace on 2017-07-24T19:22:03Z (GMT). No. of bitstreams: 1 Gisele F Dias.pdf: 1544907 bytes, checksum: e1e4d6d604584ae3d34999bdc07faa65 (MD5) Previous issue date: 2016-08-26 / The aim of the study was to evaluate the effect of dolomite (DMT) and casein fosfopeptídea amorphous calcium phosphate (CPP-ACP) in chemical and mechanical properties of emineralized dentin deciduous. For the experiment 1:analyzed the toxicity, chemical properties and release of calcium (Ca) and magnesium (Mg) ions with bioassay Artemia Salina, hydrogen potential (pH), diffraction (XRD) and X-ray fluorescence (XRF) of 4 samples of DMT and calcium hydroxide PA (Ca(OH)2). For the experiments 2 and 3 in vitro evaluated in sound and demineralized dentin the action potential of remineralization of DMT powder and in CPP-ACP sealed with glass ionomer cement (GIC) of high viscosity. In 80 primary molars were performed cavities class I. The teeth were divided into groups 1 and 2 /(pH cycling) and DMT; CPP-ACP. After pH cycling (n = 40) the cavity half was insulated with enamel, obtaining two places a direct contact with the GIC and other control. 4 groups were formed according to the material used and dentin condition.The restored teeth were sliced (slices of n = 3) in the mesial-distal direction. The hardness data were analyzed considering the contact areas (C) and no contact (NC),with ANOVA 2 Bonferroni post-test criteria for dentine factors (sound and demineralized), treatment (with and without treatment) and interaction (treating and dentin). The level of significance used was 5% (α = 0.05). Data from energy dispersive spectroscopy (EDS), electron microscope high resolution scan (FEG) and Micro Raman were analyzed by groups. Results Experiment 1 : XRD and XRF detected the presence of elements in addition to pure DMT and Ca(OH)2 to expectations of approximately 100% portlandite. The toxicity test resulted in non-toxic amounts of DMTs. The test pH DMTs in the framed pattern alkalinity. There was a significant release of Ca and Mg ions. Results Experiment 2: area NC significant difference was found for the dentin factor (p = 0.0001). The interaction dentin and treatment was not significant (p = 0.238). Area C: there was no significant difference in relation to dentin (p = 0.391). However, the direct contact area of GIC/DMT was no significant difference in the interaction dentin and treatment (p = 0.001). Results Experiment 3: hardness values increased in area C for all groups (p <0.001); no significant change in hardness values after the application of CPP-ACP (p> 0.05). In the evaluation of the FEG and EDS, the direct contact of demineralized dentin/CPPACP/ GIC resulted in increased peak phosphorus (P) ion. Changes in hardness occurred by direct contact of the material with the dentin surface (dentin and treatment). The demineralized dentin was the most reactive substrate in experiments 2 and 3. The experiment1: we conclude that the DMT is non-toxic, alkaline pH and releases Ca ions. Experiment 2: Isolated DMT determined improvement of demineralized dentin with effect on chemical and mechanical properties of demineralized dentin. Experiment 3: CPP-ACP associated with GIC promoted the increase of P ion. The ionic exchange between GIC, CPP-ACP and demineralized dentin induced changes in the chemical properties of the dentin. / O objetivo do estudo foi avaliar o efeito da dolomita(DMT) e caseína fosfopeptídea fosfato de cálcio amorfo(CPP-ACP) nas propriedades químico-mecânicas da dentina decídua desmineralizada. Para o experimento 1: foram analisados a toxicidade, propriedades químicas e liberação de íons cálcio e magnésio, com bioensaio com Artemia Salina, potencial hidrogeniônico(pH), difração(DRX) e fluorescência de raios X(FRX) de 4 amostras de DMT e do hidróxido de cálcio PA (Ca(OH)2). Nos experimentos 2 e 3, in vitro, avaliou-se em dentina hígida e desmineralizada, a ação potencial de remineralização da DMT em pó e do CPPACP selados com cimento de ionômero de vidro(CIV) de alta viscosidade. Em 80 molares decíduos foram realizadas cavidades classe I. Os dentes foram divididos em grupos 1 e 2/ (ciclagem de pH) e DMT; CPP-ACP. Após ciclagem de pH(n=40) a metade cavitária foi isolada com esmalte, obtendo-se dois sítios, um de contato direto com o CIV e outro controle. Formou-se 4 grupos, de acordo com o material empregado e a condição dentinária. Os dentes restaurados foram fatiados (fatias de n=3) no sentido mésio-distal. Os dados de dureza foram analisados considerando as áreas de contato(C) e sem contato(SC), com ANOVA 2 critérios pós-teste de Bonferroni para os fatores dentina(hígida e desmineralizada), tratamento(sem e com tratamento) e interação(dentina e tratamento). O nível de significância empregado foi de 5%(α=0,05). Os dados do espectroscopia de energia dispersiva(EDS), FEG(microscópio eletrônico de varredura de alta resolução) e Micro Raman foram analisados por grupos. Resultados experimento 1:DRX e FRX detectaram a presença de elementos além da DMT pura e o Ca(OH)2 correspondeu às expectativas de aproximadamente 100% de portlandita. O teste de toxicidade resultou em valores atóxicos das DMTs. O teste do pH enquadrou as DMTs no padrão de alcalinidade. Houve liberação significativa de íons cálcio(Ca) e magnésio(Mg). Resultados experimento 2: área SC diferença significativa foi encontrada para o fator dentina (p=0,0001). A interação dentina e tratamento não foi significativa (p=0,238). Área C: não houve diferença significativa em relação à dentina (p= 0,391). No entanto, a área de contato direto CIV/DMT houve diferença significativa na interação dentina e tratamento (p=0,001). Resultados experimento 3: os valores de dureza aumentaram na área C para em todos os grupos (p <0,001); não houve alteração significativa em valores de dureza após a aplicação de CPP-ACP (p> 0,05). Na avaliação do FEG e EDS, o contato direto da dentina desmineralizada/CPP-ACP/CIV resultou no aumento de pico do íon fósforo(P). As alterações em dureza ocorreram pelo contato direto do material com a superfície dentinária (dentina e tratamento). A dentina desmineralizada foi o substrato mais reativo nos experimentos 2 e 3. O experimento1 conclui que a DMT é atóxica, pH alcalino e libera íons Ca. O experimento 2 conclui que A DMT isolada determinou melhora do substrato dentinário desmineralizado de repercussão nas propriedades químicas-mecânicas da dentina desmineralizada. O experimento 3 conclui que o CPP-ACP associado ao CIV promoveu o incremento do íon P. As trocas iônicas entre CIV, CPP-ACP e dentina desmineralizada promoveram mudanças das propriedades químicas do substrato dentinário. Palavras-chave: Cimentos de ionômeros de vidro, dentina, desmineralização, remineralização dentária.
560

Efeito da escovação simulada sobre cimentos de ionômero de vidro indicados para tratamento restaurador atraumático

Thomassewski, Manoela Hass Dolinski 26 February 2008 (has links)
Made available in DSpace on 2017-07-24T19:22:05Z (GMT). No. of bitstreams: 1 MANOELA HASS DOLINSKI THOMASSEWSKI.pdf: 1885236 bytes, checksum: f6df4dd8ee0fdb0bea20dba5b9c53058 (MD5) Previous issue date: 2008-02-26 / The purpose of this study was to measure mass loss and surface roughness (Ra) changes of differents glass ionomer cement indicated to atraumatic restorative treatment, with a resin composite used as control material, after a simulated toothbrushing test. The surface characteristics before and after abrasion were evaluated on scanning electron microscopy (SEM). The tested materials were: Vitro Fil LC® ,Fuji IX® , Vitro Molar® , Maxxion R®, and the resin composite Filtek Z100®. Ten samples (6mm in diameter and 5mm thick) on all samples from each were prepared according to manufacturers’ instructions. Toothbrushing abrasion was performed on all specimens from each of the materials using a simulator. The mass loss, surface roughness and qualitative analyse were assessed before and after 20000 brushstrokes, using Shimadzu analytical balance of 0,0001g accuracy, a Mitutoyo surftest-301 and Shimadzu SSX-550 Superscan respectively. The measurements of both properties were statiscally compared by Anova one-way and then paired t-test and Tukey’s test. Correlation between mass loss and surface roughness was calculated. The level significance was α=5% (p<0,05). All materials presented a statistically significant mass loss comparing initial and final values. The loss mass in order decreasing was Vitro Fil LC>Maxxion R> Vitro Molar>Filtek Z100>Fuji IX. All materials became rougher with the exception of Vitro Molar that presented low roughness after toothbrushing test. There was no correlation between wear and surface roughness and SEM observations were in accordance to those roughness measured. In conclusion, the findings of this study showed that, the high viscosity glass cement ionomer presented wear and roughness seems to control material and the fluoride release propertie, this may be adequate for atraumatic restorative treatment. However, long-term clinical evaluation are necessary to better indicate this category of materials / O objetivo deste estudo foi mensurar a perda de massa e as alterações de rugosidade média superficial (Ra) de diferentes cimentos de ionômero de vidro indicados para tratamento restaurador atraumático tendo uma resina composta como material controle, após teste de escovação simulada. As características de superfície antes e após abrasão foram avaliadas em microscópio eletrônico de varredura (MEV). Os materiais testados foram: Vitro Fil LC® ,Fuji IX® , Vitro Molar® , Maxxion R®, e a resina composta microhíbrida Filtek Z100®. Dez amostras (6mm de diâmetro e 5mm de espessura) de cada material foram confeccionados de acordo com as instruções do fabricante. O teste foi conduzido em uma máquina de escovação simulada, em todas as amostras de todos os materiais, totalizando 20000 ciclos. Antes e após o teste, a massa, rugosidade e analise qualitativa em MEV, de cada material foram aferidas em um balança analítica Shimadzu de 0,0001g de precisão, pelo equipamento Mitutoyo modelo surftest-301 e pelo microscópio Shimadzu SSX-550 Superscan., respectivamente. Os resultados das variáveis perda de massa e rugosidade foram analisados pelo teste ANOVA de um critério e então o pós-teste para comparações múltiplas de Tukey, com o objetivo de identificar entre quais grupos situavam as diferenças. Para analisar a relação entre perda de massa e rugosidade média foi utilizada a análise de regressão linear. O nível de significância empregado foi de α=5% (p<0,05), utilizado para todas as análises. Todos os materiais apresentaram diferenças estatísticas de perda de massa entre valores iniciais e finais. A perda de massa em ordem decrescente foi Vitro Fil LC>Maxxion R> Vitro Molar>Filtek Z100>Fuji IX. Os materiais se tornaram mais rugosos exceto o Vitro Molar que apresentou menor rugosidade após teste. Não houve correlação entre perda de massa e rugosidade superficial. Observações ao MEV estavam de acordo com as medidas de rugosidade. Concluindo, os achados deste estudo mostraram que os cimentos de alta viscosidade apresentaram desgaste e rugosidade semelhantes ao material controle e ainda possuem a propriedade de liberar flúor, sendo adequado para tratamento restaurador atraumático. Entretanto, avaliações clínicas são necessárias para melhor indicar esta categoria de material.

Page generated in 0.0311 seconds