Desempenho da leitura em pacientes com glaucoma e acuidade visual de 20/20 / Reading performance in glaucoma patients with 20-20 visual acuityGuimarães, Aron Barbosa Caixeta, 1984- 26 August 2018 (has links)
Orientadores: Keila Miriam Monteiro de Carvalho, Vital Paulino Costa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-26T23:17:16Z (GMT). No. of bitstreams: 1
Guimaraes_AronBarbosaCaixeta_M.pdf: 3821530 bytes, checksum: ac0531c33178347f86a1927a76e2ce56 (MD5)
Previous issue date: 2015 / Resumo: Investigar a influência dos defeitos do campo visual (CV) no desempenho de leitura de pacientes com glaucoma primário de ângulo aberto (GPAA) e 20/20 de acuidade visual. Métodos: Realizou-se um estudo transversal em 35 pacientes com GPAA e 35 controles pareados por idade, todos com 20/20 de acuidade visual em pelo menos um dos olhos. Os indivíduos foram submetidos à biomicroscopia com lâmpada de fenda, tonometria de aplanação, gonioscopia, exame do nervo óptico com uma lente de 78 dioptrias e perimetria computadorizada com Humphrey Field Analyzer (Sita Standard 24-2). A velocidade de leitura monocular foi avaliada usando-se a tabela Minnesota Low Vision Reading Test (MNREAD) em uma versão traduzida e validada para o português. No grupo dos pacientes com glaucoma, caso ambos os olhos fossem elegíveis, o olho com maior defeito de CV, representado pelo menor Mean Deviation (MD) foi incluído. No grupo controle o olho participante foi escolhido aleatoriamente. Os parâmetros obtidos através do MNREAD foram a Velocidade Máxima de Leitura (VML), o Tamanho Crítico de Letra (TCL) e a Acuidade de Leitura (AL). Resultados: A média da VML nos pacientes com glaucoma (125,04 ± 38,36 palavras por minuto) foi significativamente menor do que no grupo controle (183,95 ± 15,54, p = 0,001). A média do TCL nos pacientes (0,09 ± 0,16 palavras por minuto) foi significativamente maior do que no grupo controle (-0,01 ± 0,07, p = 0,003). A média da AL nos pacientes (-0,17± 0,07) não apresentou diferença estatisticamente significativa em relação ao grupo controle (-0,19 ± 0,07, p = 0,469). A VML apresentou uma correlação positiva muito forte com MD nos pacientes com glaucoma (r = 0,954, p = 0,01). TCL teve uma correlação negativa muito forte com MD no grupo dos pacientes (r = -0,827, p = 0,01). AL apresentou uma correlação negativa substancial com MD no grupo dos pacientes (r = -0,624, p = 0,01). No grupo controle verificou-se correlação negativa baixa entre VML e MD (r = -0,132, p = 0,449), correlação negativa ínfima entre AL e MD (r = -0,076, p = 0,664) e uma correlação negativa moderada entre TCL e MD (r = -0,375, p = 0,026). Conclusões: Pacientes com glaucoma e acuidade visual 20/20 apresentam um comprometimento no desempenho de leitura que se relaciona com a gravidade do defeito no CV / Abstract: To investigate the influence of visual field defects on the reading performance of patients with primary open-angle glaucoma (POAG) and 20/20 visual acuity. Methods: This was a Cross-sectional study of 35 POAG patients and 35 age-matched controls, all with 20/20 visual acuity in at least one eye. All individuals underwent slit-lamp biomicroscopy, applanation tonometry, gonioscopy, optic nerve examination with a 78-D lens and automated perimetry performed with the Humphrey Field Analyzer (Sita Standard 24-2). Monocular reading speed was assessed using the Minnesota Low Vision Reading chart (MNREAD) in a translated and validated Portuguese version. In the patient group, if both eyes were eligible, the eye with more advanced visual field defect, characterized by the lowest Mean Deviation (MD), was included. Only one eye of each healthy participant was randomly included in the study. The parameters obtained with the MNREAD were Maximum Reading Speed (MRS), Critical Print Size Size (CPS) and Reading Acuity (RA). Results: Mean MRS in the POAG group (125.04 ± 38.36 words per minute) was significantly lower than in the control group (183.95 ± 15.54; p = 0.001). Mean CPS in the POAG group (0.09 ± 0.16 words per minute) was significantly larger than in the control group (-0.01 ± 0.07; p = 0.003). Mean RA in the POAG group (-0.17 ± 0.07) showed no statistically significant difference from the control group (-0.19 ± 0.07, p = 0.469). MRS presented a very strong positive correlation with visual field MD in the POAG group (r = 0.954, p = 0.01). CPS presented very strong negative correlation with MD in the POAG group (r = -0.827, p = 0.01). RA presented a substantial negative correlation with MD in the POAG group (r = -0.624, p = 0.01). MRS presented a weak negative correlation with visual field MD in the control group (r = -0.132, p = 0.449). RA presented a very weak negative correlation with visual field MD in the control group (r = -0.076, p = 0.664). CPS presented a moderate negative correlation with visual field MD in the control group (r = -0.375, p = 0.026). Conclusions: Glaucoma patients with 20/20 visual acuity show impairment in reading performance that correlates with the severity of the visual field defect / Mestrado / Oftalmologia / Mestre em Ciências Médicas
|
2 |
Avaliação das camadas internas e externas da retina com tomografia de coerência óptica, eletrorretinograma multifocal e perimetria automatizada padrão em olhos com atrofia em banda do nervo óptico / Evaluation of inner and outer retinal layers with optical coherence tomography, multifocal electroretinography and standard automated perimetry in eyes with band atrophy of the optic nerveAraujo, Rafael Barbosa de 19 January 2018 (has links)
Objetivos: Comparar as alterações de espessura das camadas da retina macular adquiridas com tomografia de coerência óptica (TCO) e as amplitudes das ondas de eletrorretinograma multifocal (ERGmf) convencional e com estímulo lentificado entre olhos com hemianopsia temporal sequelar por compressão quiasmática e controles saudáveis, além de avaliar as correlações entre TCO, ERGmf e campo visual (CV) central. Métodos: Quarenta e três olhos (30 pacientes) com hemianopsia temporal sequelar por tumores hipofisários previamente submetidos a descompressão quiasmática e 37 olhos saudáveis (19 controles) foram submetidos a TCO-DS da mácula, ERGmf e CV tipo 10-2. Após segmentação, foram medidas as espessuras maculares da camada de fibras nervosas da retina (CFNR), camada de células ganglionares (CCG), camada plexiforme interna (CPI), camada nuclear interna (CNI), camada plexiforme externa (CPE), camada nuclear externa (CNE) e camada de fotorreceptores (CFR). Amplitudes e potenciais oscilatórios (PO) multifocais foram adquiridos com o ERGmf convencional e com estímulo lentificado, respectivamente, analisados em valores médios por quadrantes e hemicampos. Resultados: Espessuras da CFNR, CCG e CPI foram significantemente menores em todos os quadrantes, enquanto CNI, CPE e CFR tiveram medidas significantemente maiores nos quadrantes nasais nos pacientes comparados com os controles. Correlações significantes entre a TCO e os valores de CV 10-2 foram positivas para CFNR, CCG e CPI, e negativas para CNI, CPE e CFR. As amplitudes médias dos POs e de N1 do ERGmf se mostraram significantemente reduzidas na hemirretina nasal dos pacientes. Correlações significantes foram encontradas entre as amplitudes de PO e ERGmf para com medidas de TCO da hemirretina nasal interna e externa, respectivamente. Conclusões: Pacientes com hemianopsia temporal sequelar por compressão quiasmática previamente tratada apresentam adelgaçamento significante de CFNR, CCG e CPI e espessamento de CNI, CPE e CFR, associados com amplitudes reduzidas de PO e N1, sugerindo que o dano axonal à retina interna desencadeia lesão secundária das camadas externas da retina nesta condição / Purpose: To compare optical coherence tomography (OCT)-measured macular retinal layers in eyes with permanent temporal hemianopia from chiasmal compression and controls, compare regular and slow-flash multifocal electroretinography (mfERG) in patients and controls, and assess the correlation between OCT, mfERG and central visual field (VF) data. Methods: Forty-three eyes (30 patients) with permanent temporal hemianopia from pituitary tumors previously submitted to chiasm decompression and 37 healthy eyes (19 controls) were submitted to macular SD-OCT, mfERG and 10-2 VF testing. After segmentation, macular retinal nerve fiber layer (RNFL), ganglion cell layer (GCL), inner plexiform layer (IPL), inner nuclear layer (INL), outer plexiform layer (OPL), outer nuclear layer (ONL) and photoreceptor layer plus (PRL+) thickness was measured. Amplitudes and oscillatory potentials (OP) were measured on regular and slow-flash mfERG, respectively, and expressed as mean values per quadrant and hemifield. Results: RNFL, GCL and IPL thickness measurements were significantly reduced in all quadrants while INL, OPL and PRL were significantly increased in the nasal quadrants in patients compared to controls. Significant correlations between OCT and 10-2 SAP measurements were positive for RNFL, GCL and IPL and negative for INL, OPL and PRL. OPs and mfERG N1 amplitudes were significantly reduced in the nasal hemiretina of patients. Significant correlations were found between OP and mfERG amplitudes for inner and outer nasal hemiretina OCT measurements, respectively. Conclusions: Patients with permanent temporal hemianopia from previously treated chiasmal compression displayed significant RNFL, GCL, IPL thinning and INL, OPL and PRL thickening associated with reduced OP and mfERG N1 amplitudes, suggesting axonal injury to the inner retina leads to secondary damage to the outer retina in this condition
|
3 |
Avaliação das camadas internas e externas da retina com tomografia de coerência óptica, eletrorretinograma multifocal e perimetria automatizada padrão em olhos com atrofia em banda do nervo óptico / Evaluation of inner and outer retinal layers with optical coherence tomography, multifocal electroretinography and standard automated perimetry in eyes with band atrophy of the optic nerveRafael Barbosa de Araujo 19 January 2018 (has links)
Objetivos: Comparar as alterações de espessura das camadas da retina macular adquiridas com tomografia de coerência óptica (TCO) e as amplitudes das ondas de eletrorretinograma multifocal (ERGmf) convencional e com estímulo lentificado entre olhos com hemianopsia temporal sequelar por compressão quiasmática e controles saudáveis, além de avaliar as correlações entre TCO, ERGmf e campo visual (CV) central. Métodos: Quarenta e três olhos (30 pacientes) com hemianopsia temporal sequelar por tumores hipofisários previamente submetidos a descompressão quiasmática e 37 olhos saudáveis (19 controles) foram submetidos a TCO-DS da mácula, ERGmf e CV tipo 10-2. Após segmentação, foram medidas as espessuras maculares da camada de fibras nervosas da retina (CFNR), camada de células ganglionares (CCG), camada plexiforme interna (CPI), camada nuclear interna (CNI), camada plexiforme externa (CPE), camada nuclear externa (CNE) e camada de fotorreceptores (CFR). Amplitudes e potenciais oscilatórios (PO) multifocais foram adquiridos com o ERGmf convencional e com estímulo lentificado, respectivamente, analisados em valores médios por quadrantes e hemicampos. Resultados: Espessuras da CFNR, CCG e CPI foram significantemente menores em todos os quadrantes, enquanto CNI, CPE e CFR tiveram medidas significantemente maiores nos quadrantes nasais nos pacientes comparados com os controles. Correlações significantes entre a TCO e os valores de CV 10-2 foram positivas para CFNR, CCG e CPI, e negativas para CNI, CPE e CFR. As amplitudes médias dos POs e de N1 do ERGmf se mostraram significantemente reduzidas na hemirretina nasal dos pacientes. Correlações significantes foram encontradas entre as amplitudes de PO e ERGmf para com medidas de TCO da hemirretina nasal interna e externa, respectivamente. Conclusões: Pacientes com hemianopsia temporal sequelar por compressão quiasmática previamente tratada apresentam adelgaçamento significante de CFNR, CCG e CPI e espessamento de CNI, CPE e CFR, associados com amplitudes reduzidas de PO e N1, sugerindo que o dano axonal à retina interna desencadeia lesão secundária das camadas externas da retina nesta condição / Purpose: To compare optical coherence tomography (OCT)-measured macular retinal layers in eyes with permanent temporal hemianopia from chiasmal compression and controls, compare regular and slow-flash multifocal electroretinography (mfERG) in patients and controls, and assess the correlation between OCT, mfERG and central visual field (VF) data. Methods: Forty-three eyes (30 patients) with permanent temporal hemianopia from pituitary tumors previously submitted to chiasm decompression and 37 healthy eyes (19 controls) were submitted to macular SD-OCT, mfERG and 10-2 VF testing. After segmentation, macular retinal nerve fiber layer (RNFL), ganglion cell layer (GCL), inner plexiform layer (IPL), inner nuclear layer (INL), outer plexiform layer (OPL), outer nuclear layer (ONL) and photoreceptor layer plus (PRL+) thickness was measured. Amplitudes and oscillatory potentials (OP) were measured on regular and slow-flash mfERG, respectively, and expressed as mean values per quadrant and hemifield. Results: RNFL, GCL and IPL thickness measurements were significantly reduced in all quadrants while INL, OPL and PRL were significantly increased in the nasal quadrants in patients compared to controls. Significant correlations between OCT and 10-2 SAP measurements were positive for RNFL, GCL and IPL and negative for INL, OPL and PRL. OPs and mfERG N1 amplitudes were significantly reduced in the nasal hemiretina of patients. Significant correlations were found between OP and mfERG amplitudes for inner and outer nasal hemiretina OCT measurements, respectively. Conclusions: Patients with permanent temporal hemianopia from previously treated chiasmal compression displayed significant RNFL, GCL, IPL thinning and INL, OPL and PRL thickening associated with reduced OP and mfERG N1 amplitudes, suggesting axonal injury to the inner retina leads to secondary damage to the outer retina in this condition
|
4 |
Potencial evocado visual multifocal em olhos com hemianopsia temporal por compressão quiasmática. Correlação com a perimetria computadorizada e a tomografia de coerência óptica / Multifocal visual evoked potential in eyes with temporal hemianopia from chiasmal compression. Correlation with standard automated perimetry and OCT findingsSousa, Rafael Miranda 05 May 2017 (has links)
OBJETIVO: Avaliar a capacidade do potencial visual evocado multifocal (PEV-mf) em diferenciar pacientes portadores de hemianopsia temporal de controles normais e avaliar a correlação entre o PEV-mf, o campo visual (CV) realizado com a perimetria automatizada e a tomografia de coerência óptica de domínio fourier (TCO-dF). MÉTODOS: Vinte sete olhos de 21 pacientes com defeito de campo visual temporal secundário a compressão quiasmática e 43 olhos de 23 controles normais foram submetidos aos exames PEV-mf, CV e TCO-dF (3D OCT-1000®, Topcon) da mácula e da camada de fibras nervosas da retina (CFNR). Foi calculada a média das respostas do PEV-mf global, do PEV-mf central e a média de espessura do TCO-dF da mácula para cada quadrante e para cada hemicampo, enquanto a espessura da CFNR foi dividida em 12 setores ao redor do nervo óptico. A perda de CV foi calculada para os quatro quadrantes e para os hemicampos temporal e nasal no CV 24-2 e CV 10-2. Os dois grupos foram comparados utilizando equações de estimativas generalizadas (GEE) e as correlações entre o PEV-mf, CV e o TCO-dF foram calculadas. RESULTADOS: As médias das amplitude P1 e N2 do PEV-mf global e central para os hemicampos e os quadrantes temporais foram significativamente menores nos pacientes que nos controles (p < 0.004). Não houve diferença estatística entre os grupos para os parâmetros de amplitudes do PEV-mf nos setores nasais. Não houve diferença estatística nas médias das latências do PEV-mf global e central entre os pacientes e os controles normais. Foi encontrada correlação moderada, estatisticamente significativa, entre os parâmetros de amplitudes temporais do PEV-mf - global e central com a perda de CV 24-2 e 10-2 temporal, assim como com as medidas de espessura macular e da espessura CFNR na TCO-dF. CONCLUSÕES: As médias das amplitudes do PEV-mf foram capazes de diferenciar olhos de pacientes com hemianopsia dos controles normais e apresentaram correlação significativa com os dados obtidos pela perimetria automatizada e pelo TCO-dF. Estes dados sugerem que o PEV-mf global e central podem ser utilizados na detecção de anormalidades do campo visual em pacientes portadores de compressão quiasmática / PURPOSE: To evaluate the ability of multifocal visual evoked potential (mfVEP) to differentiate patients with temporal hemianopia due to chiasmal compression from normal controls. To assess the relationship between mfVEP, standard automated perimetry (SAP) and fourier domain-optical coherence tomography (fd-OCT). METHODS: Twenty-seven eyes of 21 patients with permanent temporal visual field (VF) defects from chiasmal compression and 43 eyes of 23 healthy controls underwent mfVEP, SAP and fd-OCT (3D OCT-1000®, Topcon) macular and peripapillary retinal nerve fiber layer (RNFL) measurements. It was averaged the responses for global mfVEP, central mfVEP and fd-OCT macular measurements were averaged in quadrants and halves, while peripapillary RNFL thickness was averaged in 12 sectors around the disc. VF loss was estimated in four quadrants and each half of 24-2 and 10-2 strategy test points. The two groups were compared using generalized estimated equations (GEE). Correlations between mfVEP, VF and fd-OCT findings were verified. RESULTS: Global and central mfVEP P1 and N2 amplitude parameters of temporal measurements were significantly smaller in patients than controls (p < 0.004). No significant differences were observed between the groups with respect to mfVEP amplitude parameters from the nasal measurements. No significant differences were observed in global and central mfVEP latency parameters for all averaged measurements between patients and healthy controls. A significant moderate correlation was found between global and central mfVEP amplitude parameters of temporal measurements and temporal VF 24-2 and 10-2 loss as well as with corresponding fd-OCT macular and RNFL thickness measurements. CONCLUSIONS: mfVEP amplitude parameters were able to differentiate eyes with temporal hemianopia from controls and were significant correlated with VF and fd-OCT findings. These data suggest that it is a useful technology for detecting visual abnormalities in patients with chiasmal compression
|
5 |
Potencial evocado visual multifocal em olhos com hemianopsia temporal por compressão quiasmática. Correlação com a perimetria computadorizada e a tomografia de coerência óptica / Multifocal visual evoked potential in eyes with temporal hemianopia from chiasmal compression. Correlation with standard automated perimetry and OCT findingsRafael Miranda Sousa 05 May 2017 (has links)
OBJETIVO: Avaliar a capacidade do potencial visual evocado multifocal (PEV-mf) em diferenciar pacientes portadores de hemianopsia temporal de controles normais e avaliar a correlação entre o PEV-mf, o campo visual (CV) realizado com a perimetria automatizada e a tomografia de coerência óptica de domínio fourier (TCO-dF). MÉTODOS: Vinte sete olhos de 21 pacientes com defeito de campo visual temporal secundário a compressão quiasmática e 43 olhos de 23 controles normais foram submetidos aos exames PEV-mf, CV e TCO-dF (3D OCT-1000®, Topcon) da mácula e da camada de fibras nervosas da retina (CFNR). Foi calculada a média das respostas do PEV-mf global, do PEV-mf central e a média de espessura do TCO-dF da mácula para cada quadrante e para cada hemicampo, enquanto a espessura da CFNR foi dividida em 12 setores ao redor do nervo óptico. A perda de CV foi calculada para os quatro quadrantes e para os hemicampos temporal e nasal no CV 24-2 e CV 10-2. Os dois grupos foram comparados utilizando equações de estimativas generalizadas (GEE) e as correlações entre o PEV-mf, CV e o TCO-dF foram calculadas. RESULTADOS: As médias das amplitude P1 e N2 do PEV-mf global e central para os hemicampos e os quadrantes temporais foram significativamente menores nos pacientes que nos controles (p < 0.004). Não houve diferença estatística entre os grupos para os parâmetros de amplitudes do PEV-mf nos setores nasais. Não houve diferença estatística nas médias das latências do PEV-mf global e central entre os pacientes e os controles normais. Foi encontrada correlação moderada, estatisticamente significativa, entre os parâmetros de amplitudes temporais do PEV-mf - global e central com a perda de CV 24-2 e 10-2 temporal, assim como com as medidas de espessura macular e da espessura CFNR na TCO-dF. CONCLUSÕES: As médias das amplitudes do PEV-mf foram capazes de diferenciar olhos de pacientes com hemianopsia dos controles normais e apresentaram correlação significativa com os dados obtidos pela perimetria automatizada e pelo TCO-dF. Estes dados sugerem que o PEV-mf global e central podem ser utilizados na detecção de anormalidades do campo visual em pacientes portadores de compressão quiasmática / PURPOSE: To evaluate the ability of multifocal visual evoked potential (mfVEP) to differentiate patients with temporal hemianopia due to chiasmal compression from normal controls. To assess the relationship between mfVEP, standard automated perimetry (SAP) and fourier domain-optical coherence tomography (fd-OCT). METHODS: Twenty-seven eyes of 21 patients with permanent temporal visual field (VF) defects from chiasmal compression and 43 eyes of 23 healthy controls underwent mfVEP, SAP and fd-OCT (3D OCT-1000®, Topcon) macular and peripapillary retinal nerve fiber layer (RNFL) measurements. It was averaged the responses for global mfVEP, central mfVEP and fd-OCT macular measurements were averaged in quadrants and halves, while peripapillary RNFL thickness was averaged in 12 sectors around the disc. VF loss was estimated in four quadrants and each half of 24-2 and 10-2 strategy test points. The two groups were compared using generalized estimated equations (GEE). Correlations between mfVEP, VF and fd-OCT findings were verified. RESULTS: Global and central mfVEP P1 and N2 amplitude parameters of temporal measurements were significantly smaller in patients than controls (p < 0.004). No significant differences were observed between the groups with respect to mfVEP amplitude parameters from the nasal measurements. No significant differences were observed in global and central mfVEP latency parameters for all averaged measurements between patients and healthy controls. A significant moderate correlation was found between global and central mfVEP amplitude parameters of temporal measurements and temporal VF 24-2 and 10-2 loss as well as with corresponding fd-OCT macular and RNFL thickness measurements. CONCLUSIONS: mfVEP amplitude parameters were able to differentiate eyes with temporal hemianopia from controls and were significant correlated with VF and fd-OCT findings. These data suggest that it is a useful technology for detecting visual abnormalities in patients with chiasmal compression
|
6 |
Tomografia de coerência óptica em olhos glaucomatosos com defeito assimétrico de hemicampo visual / Optical coherence tomography in glaucomatous eyes with assymetrical hemifield lossReis, Alexandre Soares Castro 08 November 2013 (has links)
Objetivo: Estudar as medidas de espessura da camada de fibras nervosas da retina(CFNR) peripapilar obtidas com as tomografias de coerência óptia (oCT) time domain (TD) e spectral domain (SD) em pacientes com perda assimétrica glaucomatosa de hemicampo visual, compará-las entre si e com aquelas de controles normais. Métodos: Trinta e seis pacientes com glaucoma primário de ângulo aberto e perda de campo visual em um hemicampo (afetado) e ausência de perda no hemicampo oposto (não afetado), e 36 controles pareados por idade tiveram o olho de estudo examinado com Stratus-OCT (Carl Zeiss Meditec Inc., Dublin, Califoprnia, USA) e o 3DOCT-1000 (Topcdon, Tokyo, Japan). As medidas de espessura da CFNR peripapilar e a classificação normativa fornecida pelos aparelhos foram registrados para análise. A média aritmética dos valores do mapa total deviation em cada hemicampo (mean deviation do hemicampo) foi calculada para cada indivíduo. \"Ìndices de assimetria\" para o campo visual e para a CFNR foram calculados como a razão entre o mean deviation dos hemicampos afetado e não-afetado, e como razão entre a espessura da CFNR das hemirretinas afetada e não-afetada, respectivamente. As variáveis contínuas foram comparadas usando os testes de Mann-Whitney, Kruskal-Wallis ou Wilcoxon, quando apropriados. As variáveis categóricas foram comparadas usando o teste qui-quadrado de Pearson. O coeficiente de correlação de Spearman foi usado para testar as correlações entre as medidas de espessura da CFNR fornecidas pelos OCTs. A presença de afinamento da CFNR foi estabelecida com base nos dados normativos fornecidos pelos softwares dos OCTs. As espessuras de CFNR fora do intervalo de previsão de 95% para a mesma faixa etária foram consideradas anormais. Resultados: As medidas de CFNR corespondentes a hemicampos não-afetados [média (DP) 87,0 (17,1) um e 84,3 (20,2) um, para TD e SD-OCT, respectivamente] foram menores do que as dos controles [média (DP) 119,0 (122,2)um e 117,0 (17,7) um, para TD e SD-OCT, respectivamente, P < 0,001, para ambos]. O banco de dados normativo classificou como alterado 42% e 67% das hemirretinas correspondentes a hemicampos não-acometidos com TD e SD-OCT, respectivamente (P = 0,01). As medidas da CFNR foram consistentemente mais espessas com TD comparadas com SD-OCT. Os índices de assimetria da CFNR em pacientes com glaucoma foram semelhantes entre TD [média (DP) 0,76 (0,17)] e SD-OCT [média (DP) 0,79 (0,12), P = 0,89] e significantemente maiores do que o índice de assimetria do campo visual [média (DP) 0,36 (0,20), P < 0,001]. Conclusões: Os hemicampos normais de pacientes com glaucoma apresentaram CFNR mais fina do que de olhos saudáveis. As medidas da CFNR foram mais espessas com TD do que com SD-OCT, o qual por sua vez detectou anormalidades na espessura da CFNR mais frequentemente do que o TD-OCT / Objective: To study the peripapillary retinal nerve fiber layer (RNFL) thickness measurements obtained with time domain (TD) and spectral domain (SD) optical coherence tomography (OCT) in glaucomatous patients with asymmetric visual hemifield loss, to compare themselves and with those obtained from normal controls. Methods : Thirty -six patients with primary open-angle glaucoma with visual primary open-angle glaucoma with visual field loss in one hemifield (affected ) and absence of loss in other (non-affected), and 36 age-matched healthy controls had the eye study imaged with Stratus-OCT (Carl Zeiss Meditec Inc., Dublin, Califoprnia, USA) and 3D OCT-1000 (Topcon , Tokyo, Japan). Peripapillary RNFL thickness measurements and normative classification were recorded for analysis. Total deviation values were averaged for each hemifield (hemifield mean deviation) for ecch subject. Visual field and RNFL \"asymmetry indexes\" were calculated as the ratio between the mean deviation of affected versus non-affected hemifields and RNFL thickness between as affected versus non-affected hemiretinas, respectively. Continuous variables were compared using the Mann-Whitney, Kruskal-Wallis or Wilcoxon tests, when appropriate. Categorical variables were compared using the Pearson\'s chi-square test. The Spearman\'s rank correlation coefficient was used to test correlations between RNFL thickness measurements provided by both OCTs . The presence of RNFL thinning was establised based on normative data provided by the OCT\'s software. The RNFL thicknesses outside the prediction interval of 95% for the same age group were considered abnormal. Results: The RNFL measurements in non-affected hemifields [mean (SD 87.0 (17.1) e 84.3(20.2) um, for TD and SD-OCT, respectively] were thinner than those of normal controls [mean (SD) 119.0 (12.2) um and 117.0 (17.7) um, for TD and SD-OCT, respectively, P < 0.001 for both ] . The OCT normative database classified 42 % and 67% of hemiretinas corresponding to non-affected hemifields as abnormal in TD and SD-OCT, respectively (P =0.01). The RNFL measurements were consistently thicker with TD compared with SD -OCT. The RNFL thickness asymetry index in patients with glaucoma was similar with TD [ mean (SD) 0.76 ( 0.17 ) ] and SD-OCT [ mean (SD)0.79(0.12), P = 0,89] and significantly greater than the visual field asymmetry index [ mean (SD ) 0.36 (0.20 ), P < 0.001]. Conclusions: Normal hemifields of glaucoma patients had thinner RNFL measurements than healthy eyes, as measured by TD and SD-OCT. The RNFL measurements were thicker with TD than SD-OCT, SD-OCT detected abnormal RNFL more often than TD-OCT
|
7 |
Tomografia de coerência óptica em olhos glaucomatosos com defeito assimétrico de hemicampo visual / Optical coherence tomography in glaucomatous eyes with assymetrical hemifield lossAlexandre Soares Castro Reis 08 November 2013 (has links)
Objetivo: Estudar as medidas de espessura da camada de fibras nervosas da retina(CFNR) peripapilar obtidas com as tomografias de coerência óptia (oCT) time domain (TD) e spectral domain (SD) em pacientes com perda assimétrica glaucomatosa de hemicampo visual, compará-las entre si e com aquelas de controles normais. Métodos: Trinta e seis pacientes com glaucoma primário de ângulo aberto e perda de campo visual em um hemicampo (afetado) e ausência de perda no hemicampo oposto (não afetado), e 36 controles pareados por idade tiveram o olho de estudo examinado com Stratus-OCT (Carl Zeiss Meditec Inc., Dublin, Califoprnia, USA) e o 3DOCT-1000 (Topcdon, Tokyo, Japan). As medidas de espessura da CFNR peripapilar e a classificação normativa fornecida pelos aparelhos foram registrados para análise. A média aritmética dos valores do mapa total deviation em cada hemicampo (mean deviation do hemicampo) foi calculada para cada indivíduo. \"Ìndices de assimetria\" para o campo visual e para a CFNR foram calculados como a razão entre o mean deviation dos hemicampos afetado e não-afetado, e como razão entre a espessura da CFNR das hemirretinas afetada e não-afetada, respectivamente. As variáveis contínuas foram comparadas usando os testes de Mann-Whitney, Kruskal-Wallis ou Wilcoxon, quando apropriados. As variáveis categóricas foram comparadas usando o teste qui-quadrado de Pearson. O coeficiente de correlação de Spearman foi usado para testar as correlações entre as medidas de espessura da CFNR fornecidas pelos OCTs. A presença de afinamento da CFNR foi estabelecida com base nos dados normativos fornecidos pelos softwares dos OCTs. As espessuras de CFNR fora do intervalo de previsão de 95% para a mesma faixa etária foram consideradas anormais. Resultados: As medidas de CFNR corespondentes a hemicampos não-afetados [média (DP) 87,0 (17,1) um e 84,3 (20,2) um, para TD e SD-OCT, respectivamente] foram menores do que as dos controles [média (DP) 119,0 (122,2)um e 117,0 (17,7) um, para TD e SD-OCT, respectivamente, P < 0,001, para ambos]. O banco de dados normativo classificou como alterado 42% e 67% das hemirretinas correspondentes a hemicampos não-acometidos com TD e SD-OCT, respectivamente (P = 0,01). As medidas da CFNR foram consistentemente mais espessas com TD comparadas com SD-OCT. Os índices de assimetria da CFNR em pacientes com glaucoma foram semelhantes entre TD [média (DP) 0,76 (0,17)] e SD-OCT [média (DP) 0,79 (0,12), P = 0,89] e significantemente maiores do que o índice de assimetria do campo visual [média (DP) 0,36 (0,20), P < 0,001]. Conclusões: Os hemicampos normais de pacientes com glaucoma apresentaram CFNR mais fina do que de olhos saudáveis. As medidas da CFNR foram mais espessas com TD do que com SD-OCT, o qual por sua vez detectou anormalidades na espessura da CFNR mais frequentemente do que o TD-OCT / Objective: To study the peripapillary retinal nerve fiber layer (RNFL) thickness measurements obtained with time domain (TD) and spectral domain (SD) optical coherence tomography (OCT) in glaucomatous patients with asymmetric visual hemifield loss, to compare themselves and with those obtained from normal controls. Methods : Thirty -six patients with primary open-angle glaucoma with visual primary open-angle glaucoma with visual field loss in one hemifield (affected ) and absence of loss in other (non-affected), and 36 age-matched healthy controls had the eye study imaged with Stratus-OCT (Carl Zeiss Meditec Inc., Dublin, Califoprnia, USA) and 3D OCT-1000 (Topcon , Tokyo, Japan). Peripapillary RNFL thickness measurements and normative classification were recorded for analysis. Total deviation values were averaged for each hemifield (hemifield mean deviation) for ecch subject. Visual field and RNFL \"asymmetry indexes\" were calculated as the ratio between the mean deviation of affected versus non-affected hemifields and RNFL thickness between as affected versus non-affected hemiretinas, respectively. Continuous variables were compared using the Mann-Whitney, Kruskal-Wallis or Wilcoxon tests, when appropriate. Categorical variables were compared using the Pearson\'s chi-square test. The Spearman\'s rank correlation coefficient was used to test correlations between RNFL thickness measurements provided by both OCTs . The presence of RNFL thinning was establised based on normative data provided by the OCT\'s software. The RNFL thicknesses outside the prediction interval of 95% for the same age group were considered abnormal. Results: The RNFL measurements in non-affected hemifields [mean (SD 87.0 (17.1) e 84.3(20.2) um, for TD and SD-OCT, respectively] were thinner than those of normal controls [mean (SD) 119.0 (12.2) um and 117.0 (17.7) um, for TD and SD-OCT, respectively, P < 0.001 for both ] . The OCT normative database classified 42 % and 67% of hemiretinas corresponding to non-affected hemifields as abnormal in TD and SD-OCT, respectively (P =0.01). The RNFL measurements were consistently thicker with TD compared with SD -OCT. The RNFL thickness asymetry index in patients with glaucoma was similar with TD [ mean (SD) 0.76 ( 0.17 ) ] and SD-OCT [ mean (SD)0.79(0.12), P = 0,89] and significantly greater than the visual field asymmetry index [ mean (SD ) 0.36 (0.20 ), P < 0.001]. Conclusions: Normal hemifields of glaucoma patients had thinner RNFL measurements than healthy eyes, as measured by TD and SD-OCT. The RNFL measurements were thicker with TD than SD-OCT, SD-OCT detected abnormal RNFL more often than TD-OCT
|