Numerically Optimized Diabatic Distillation Columns

Schaller, Markus 10 July 2007 (has links) (PDF)
Im Gegensatz zur konventionellen adiabatischen Destillation erfolgt bei der diabatischen Destillation Wärmeaustausch nicht nur am Kondensator und Verdampfer, sondern auch innerhalb der Kolonne an den einzelnen Siebböden, was die Entropieproduktion (=Exergieverlust) des Destillationsprozesses stark reduziert. In dieser Arbeit werden Modellsysteme zur diabatischen Destillation von idealen binären Gemischen mittels numerischer Optimierung untersucht. Das Ausgangsmodell beschränkt sich auf die Minimierung der Entropieproduktion verursacht durch Wärme- und Massentransport im Inneren der diabatischen Destillationskolonne. Im zweiten Modell wird das diabatische Modell um die Irreversibilität bedingt durch den Wärmeaustausch mit der Umgebung erweitert. Im dritten Modellsystem wird anstelle der bis dahin voneinander unabhängig geregelten Bodentemperaturen eine diabatische Implementierung mit seriellen Wärmetauschern untersucht, die nur mehr vier Kontrollvariablen besitzt und besonders zur praktischen Anwendung geeignet ist. Für alle diabatischen Modelle werden die minimale Entropieproduktion und optimalen Betriebsprofile numerisch ermittelt, und mit konventionellen Destillationskolonnen verglichen. Alle Ergebnisse zeigen eine deutlich Reduktion der Entropieproduktion für den diabatische Fall, besonders bei Kolonnen mit vielen Böden. / Contrary to conventional adiabatic distillation, in diabatic distillation columns heat transfer not only happens at the condenser and reboiler but also at the intermediate trays which strongly reduces the entropy production (= exergy losses). In this work, model systems for the diabatic distillation of ideal binary mixtures are investigated numerically.The first model is restricted to the minimization of the entropy production due to heat and mass transfer inside the diabatic column. In the second approach the model is extended with the irreversibility due to heat transfer with the column's surroundings. Instead of independently controlled tray temperatures as in the latter models, we focus on a specific diabatic implementation with sequential heat exchangers, which has merely four controls and which is particularly suitable for practical application. For all diabatic models the minimum entropy production and resulting optimal operating profiles are determined numerically, and compared to the ones obtained for a conventional column. All results show an enormous reduction of the entropy production for the diabatic case, especially for columns with many trays.
2

Numerically Optimized Diabatic Distillation Columns

Schaller, Markus 10 July 2007 (has links)
Im Gegensatz zur konventionellen adiabatischen Destillation erfolgt bei der diabatischen Destillation Wärmeaustausch nicht nur am Kondensator und Verdampfer, sondern auch innerhalb der Kolonne an den einzelnen Siebböden, was die Entropieproduktion (=Exergieverlust) des Destillationsprozesses stark reduziert. In dieser Arbeit werden Modellsysteme zur diabatischen Destillation von idealen binären Gemischen mittels numerischer Optimierung untersucht. Das Ausgangsmodell beschränkt sich auf die Minimierung der Entropieproduktion verursacht durch Wärme- und Massentransport im Inneren der diabatischen Destillationskolonne. Im zweiten Modell wird das diabatische Modell um die Irreversibilität bedingt durch den Wärmeaustausch mit der Umgebung erweitert. Im dritten Modellsystem wird anstelle der bis dahin voneinander unabhängig geregelten Bodentemperaturen eine diabatische Implementierung mit seriellen Wärmetauschern untersucht, die nur mehr vier Kontrollvariablen besitzt und besonders zur praktischen Anwendung geeignet ist. Für alle diabatischen Modelle werden die minimale Entropieproduktion und optimalen Betriebsprofile numerisch ermittelt, und mit konventionellen Destillationskolonnen verglichen. Alle Ergebnisse zeigen eine deutlich Reduktion der Entropieproduktion für den diabatische Fall, besonders bei Kolonnen mit vielen Böden. / Contrary to conventional adiabatic distillation, in diabatic distillation columns heat transfer not only happens at the condenser and reboiler but also at the intermediate trays which strongly reduces the entropy production (= exergy losses). In this work, model systems for the diabatic distillation of ideal binary mixtures are investigated numerically.The first model is restricted to the minimization of the entropy production due to heat and mass transfer inside the diabatic column. In the second approach the model is extended with the irreversibility due to heat transfer with the column's surroundings. Instead of independently controlled tray temperatures as in the latter models, we focus on a specific diabatic implementation with sequential heat exchangers, which has merely four controls and which is particularly suitable for practical application. For all diabatic models the minimum entropy production and resulting optimal operating profiles are determined numerically, and compared to the ones obtained for a conventional column. All results show an enormous reduction of the entropy production for the diabatic case, especially for columns with many trays.
3

Universal tool LASER - application examples for welding of HT fuel cells as well as heat exchangers and tank systems for H2 processing

Standfuss, Jens, Dittrich, Dirk, Klotzbach, Annett, Mohlau, Phillip, Strohbach, Robert, Leyens, Christoph 25 November 2019 (has links)
The laser tool is predestined for automated manufacturing processes and has already proven its suit-ability in many areas. In particular, joining technologies in the field of hydrogen production, its storage and for bi-polar plates have to meet the highest requirements in terms of seam quality, reproducibility and manufacturing efficiency. By the examples  700 bar car H2 pressure tank with laser welded connection (welding depth 25 mm)  Laser Remote Welding of HT Fuel Cell Stacks  Laser-welded aluminum tube-ground heat exchanger for gas liquefaction the article presents the possibilities of modern laser beam welding technologies. Furthermore, it gives an outlook on future challenges, especially with regard to the requirements of welding bi-polar plates for upcoming applications in the field of mobility
4

Untersuchungen an einer Kolbenexpansionsmaschine mit integrierten Wärmeübertragerflächen (Wärmeübertrager-Expander) zur Realisierung eines neuartigen Neon-Tieftemperatur-Prozesses

Fredrich, Ole 01 March 2005 (has links) (PDF)
Viele Anwendungen der Hochtemperatur-Supraleitung arbeiten vorteilhaft im Temperaturbereich zwischen 30 - 50 K. Für diesen Temperaturbereich existieren nur wenige geeignete Kältemaschinen mit kleiner Kälteleistung (1-2 W) u. gutem Wirkungsgrad. Neon ist aufgrund seiner Stoffeigenschaften ein hervorragendes Kältemittel für diesen Temperaturbereich, wie z.B. anhand einer realisierten Joule-Thomson (JT) Demonstrationsanlage deutlich wird. Als Ergebnis einer Prozessanalyse wird ein Kreislauf vorgestellt, der speziell den Eigenschaften von Neon angepasst ist. Durch die Überlagerung von Wärmeübertragung u. arbeitsleistender Expansion sowie der Einbeziehung einer JT-Stufe kann auch mit wenig effizienten Komponenten ein vergleichsweise hoher Gütegrad erreicht werden. Durch die Integration von Wärmeübertragerflächen in eine Kolbenexpansionsmaschine wird ein neues Konzept vorgeschlagen, um Kälte in einem großen Temperaturbereich in vielen Expansionsschritten zu erzeugen, ohne dafür viele Expander zu verwenden. Diese Einheit wird als Wärmeübertrager-Expander (WE) bezeichnet. Mit einem Arbeitsraum in konischer Grundform wird der Wärmeübergangskoeffizient günstig gestaltet u. die Wärmeübergangsfläche vergrößert. Mehrere Versuchsmaschinen wurden untersucht. Anhand der Versuche konnten die wesentlichen Verlustquellen u. Problembereiche identifiziert werden. Es wurde im Rahmen der Versuchsbedingungen nachgewiesen, dass für das vorgesehene Druckverhältnis eine nahe isotherme Expansion u. Kompression möglich ist. Es werden Möglichkeiten zur Verringerung der Längswärmeleitung vorgestellt. Zwei Simulationsprogramme wurden verwendet. Mit Hilfe des Wärmeübertrager-Programms wurden die Wärmeübertragungsvorgänge unter Berücksichtigung der Längswärmeleitung simuliert. Hierbei geht die Expansionsarbeit als stationäre Wärmesenke ein. Der im Ergebnis vorliegende stationäre Temperaturverlauf ist die Grundlage für die Berechnung der Expansionsarbeit unter Berücksichtigung der Realgaseigenschaften im Expander-Programm. Für die Neon-Tieftemperaturvariante wurde eine Grundvariante des WE definiert. Anhand dieser wurde mit Hilfe der Programme der Einfluss verschiedener Parameter auf Kälteleistung u. Gütegrad untersucht. Der WE wird als Teil des beschriebenen Prozesses mit einer JT-Stufe betrachtet. Die Kälteleistung weist sowohl in Abhängigkeit vom Massestrom als auch vom Hub ein Maximum auf. Der Shuttle-Verlust verschiebt durch Wärmetransport mittels des Kolbens die effektive Kälteleistung zu kleineren Hüben. Die durch die Güte (NTU) des JT-Wärmeübertragers bestimmte Eintrittstemperatur des Niederdruckstroms in den WE hat einen großen Einfluss auf die Kälteleistung. Mit steigender Eintrittstemperatur steigen der NTU-Wert für den Arbeitsraum u. somit auch die Kälteleistung. Das Maximum der Kälteleistung stimmt nicht mit dem Optimum für den Gütegrad überein. Der Gütegrad strebt mit sinkenden Masseströmen einem Optimum zu. Durch den zunehmenden Einfluss der Längswärmeleitung u. begrenzt durch die Minimalfüllung der Maschine aufgrund des Schadraumes ergibt sich ein Optimum. Der Einfluss des Massestroms ist entscheidend. Als untergeordnete Größen beeinflussen die Eintrittstemperatur des Niederdruckstroms u. der Hub den optimalen Gütegrad. Der Einfluss der Längswärmeleitung auf Kälteleistung u. Gütegrad wird exemplarisch anhand von vergleichenden Rechnungen gezeigt. Konkret kann für einen Eintrittsdruck von 200 bar, einen Austrittsdruck von 60 bar bei einer Eintrittstemperatur des Niederdruckstroms von 80 K für die Grundvariante eine maximale effektive Kälteleistung von 1,3 W mit einem Massestrom von 0,22 g/ s bei einem Hub von ca. 17 mm ausgewiesen werden. Der effektive Gütegrad für diese Bedingungen beträgt ca. 14%. Kommerzielle Split-Stirlingkühler erreichen bei 42 K einstufig Gütegrade von ca. 7%. Mit der vorgeschlagenen Konfiguration wird ein Konzept vorgestellt, das trotz technologisch offener Fragen das Gütegradniveau bekannter Kryokühler übertreffen kann. / Many applications of high temperature superconductivity are working advantageously within a temperature range between 30 K and 50 K. But for this temperature range only few suitable cryocooler with small refrigerating capacity (1-2 W) and good efficiency exist.Due to its properties Neon is an excellent refrigerant for this temperature level as an example with realised Joule-Thomson plant shows. A process analysis results in the presented cycle which is especially adapted to the properties of Neon. By combination of heat exchange and work extracting expansion and integration of a Joule-Thomson stage a high efficiency could be reached in spite of less efficient components.By arranging heat exchanger surfaces into a piston expansion machine a new concept is suggested to produce refrigeration in a large temperature range with a lot of expansion steps with reduced number of expanders. This unit is referred hereinafter to as heat exchanger-expander.The conical shaped working space results in an increase of the heat transfer coefficient and the heat transfer area.Several test machines were investigated. By means of testing the main loss sources and critical zones could be identified. The test results prove the opportunity of a near isothermal expansion and compression for the specified pressure ratio.Options to reduce the axial heat conduction are presented.Two simulation programs were utilised. Using the heat exchanger program the heat transfer is simulated in consideration of the axial heat conduction. Thereby the expansion work is considered as a stationary heat sink. The resulting stationary temperature pattern is the base for the expansion work calculation using the real gas properties in the expander program. Referring to the defined basic neon low temperature application the influence of different parameters on refrigerating capacity and efficiency was researched with the programs. The heat exchanger-expander is part of the described process with a Joule-Thomson stage. The refrigerating capacity shows a maximum depending as well from the mass flow as from the stroke. In result of the shuttle loss smaller strokes lead to better capacity due to heat transport with the piston.The inlet temperature of the low pressure flow influenced by the quality (NTU) of the Joule-Thomson heat exchanger has a large influence on the refrigerating capacity. With increasing inlet temperature the number of transfer units (NTU) for the fluid in the working volume increases and so the refrigerating capacity, too. The location of refrigerating capacity maximum and efficiency optimum is different. While decreasing mass flow efficiency is increasing to an optimum caused by the increased influence of axial heat conduction but limited by the minimum charge of the machine due to the dead space. The influence of the mass flow is dominating. As lower range values the inlet temperature of the low pressure flow and the stroke are influencing the optimal efficiency. The influence of axial heat conduction on refrigerating capacity and efficiency is shown using comparing calculations.For an inlet pressure of 200 bar, an outlet pressure of 60 bar, an inlet temperature of the low pressure flow of 80 K, a mass flow of 0,22 g/ s and a stroke of about 17 mm for the basic version of heat exchanger-expander a maximal effective refrigerating capacity of 1,3 We could be shown. The effective efficiency therefore is 14 %. Current commercial split Stirling cryocooler reach with single stage operation efficiencies of about 7 % at 42 K. The suggested configuration represents a concept that could be able to master the efficiency level of known cryocooler.
5

Performance Optima for Endoreversible Systems / Optima und Grenzen von Leistungsmerkmalen Endoreversibler Systeme

Burzler, Josef Maximilian 08 January 2003 (has links) (PDF)
Theoretical bounds for performance measures of thermodynamical systems are investigated under conditions of finite times and rates of processes using endoreversible models. These models consist of reversible operating sub-systems which exchange energy via generally irreversible interactions. Analytical and numerical calculations are performed to obtain performance optima and respective optimized process and design parameters for four model systems. A heat engine where the heat transfer between the working fluid and heat reservoirs is described by generalized, polytropic process is optimized for maximum work output. Thermal efficiencies, optimal values for temperatures and process times of the heat transfer processes are determined. A model of a generalized system suited to describe the operation of heat engines, refrigerators, and heat pumps is optimized with respect to thermal efficiency. Several examples illustrate how the results of the analysis are used to allocate financial resources to the heat exchanger inventory in an optimal way. A power-producing thermal system which exchanges heat with several heat reservoirs via irreversible heat transfer processes is analyzed to find the optimal contact times between the working fluid and each of the reservoirs. The piston motion of a Diesel engine is optimized to achieve maximum work for a given amount of fuel. The endoreversible model of the Diesel engine accounts for the temporal variations of the heat produced by the combustion process, the basic flow pattern within the engine's cylinder, the temperature dependence of the viscosity, thermal conductivity, and heat capacity of the working fluid and losses due to friction and heat leak through the cylinder walls. / Theoretische Grenzen für verschiedene Leistungsmerkmale von thermodynamischen Systemen werden unter der Bedingung endlicher Zeiten und Prozessraten im Rahmen endoreversibler Modelle untersucht. Diese Modelle bestehen aus reversiblen Subsystemen, welche über allgemein irreversible Wechselwirkungen Energie austauschen. Analytische und nummerische Berechnungen quantifizieren diese Grenzen und liefern optimale Prozess- und Konstruktionsparameter für vier Modellsysteme. Für eine auf maximale Ausgangsarbeit optimierte Wärmekraftmaschine, bei der die Wärme zwischen Arbeitsmedium und Wärmereservoirs während allgemeiner polytroper Zustandsänderungen des Arbeitsmediums übertragen wird, werden optimale Temperaturen und Zeiten für die Wärmeübertragungsprozesse sowie die thermischen Wirkungsgrade bestimmt. Für ein wirkungsgrad-optimiertes Modell eines verallgemeinerten thermischen Umwandlungssytems, das sowohl Wärmekraftmaschinen, Kühler und Wärmepumpen beschreibt, wird die optimale Verteilung von Investitionskosten auf die Wärmetauscher ermittelt und die Anwendung der allgemeingültigen Ergebnisse anhand mehrerer Beispiele demonstriert. Für eine Wärmekraftmaschine mit mehreren Wärmereservoirs wird bestimmt, welche der Wärmereservoirs wie lange kontaktiert werden müssen, um eine maximale Ausgangsarbeit zu erzielen. Für einen Dieselmotor wird die Kolbenbewegung so optimiert, dass bei gegebener Treibstoffmenge eine maximale Ausgangsarbeit erzielt wird. Das endoreversible Modell des Dieselmotors berücksichtigt die Temperaturabhängigkeit der Wärmekapazität, Wärmeleitfähigkeit und Viskosität des Arbeitsfluids, die Zeitabhängigkeit des Verbrennungsprozesses sowie Reibungs- und Wärmeverluste.
6

Untersuchungen an einer Kolbenexpansionsmaschine mit integrierten Wärmeübertragerflächen (Wärmeübertrager-Expander) zur Realisierung eines neuartigen Neon-Tieftemperatur-Prozesses

Fredrich, Ole 23 April 2004 (has links)
Viele Anwendungen der Hochtemperatur-Supraleitung arbeiten vorteilhaft im Temperaturbereich zwischen 30 - 50 K. Für diesen Temperaturbereich existieren nur wenige geeignete Kältemaschinen mit kleiner Kälteleistung (1-2 W) u. gutem Wirkungsgrad. Neon ist aufgrund seiner Stoffeigenschaften ein hervorragendes Kältemittel für diesen Temperaturbereich, wie z.B. anhand einer realisierten Joule-Thomson (JT) Demonstrationsanlage deutlich wird. Als Ergebnis einer Prozessanalyse wird ein Kreislauf vorgestellt, der speziell den Eigenschaften von Neon angepasst ist. Durch die Überlagerung von Wärmeübertragung u. arbeitsleistender Expansion sowie der Einbeziehung einer JT-Stufe kann auch mit wenig effizienten Komponenten ein vergleichsweise hoher Gütegrad erreicht werden. Durch die Integration von Wärmeübertragerflächen in eine Kolbenexpansionsmaschine wird ein neues Konzept vorgeschlagen, um Kälte in einem großen Temperaturbereich in vielen Expansionsschritten zu erzeugen, ohne dafür viele Expander zu verwenden. Diese Einheit wird als Wärmeübertrager-Expander (WE) bezeichnet. Mit einem Arbeitsraum in konischer Grundform wird der Wärmeübergangskoeffizient günstig gestaltet u. die Wärmeübergangsfläche vergrößert. Mehrere Versuchsmaschinen wurden untersucht. Anhand der Versuche konnten die wesentlichen Verlustquellen u. Problembereiche identifiziert werden. Es wurde im Rahmen der Versuchsbedingungen nachgewiesen, dass für das vorgesehene Druckverhältnis eine nahe isotherme Expansion u. Kompression möglich ist. Es werden Möglichkeiten zur Verringerung der Längswärmeleitung vorgestellt. Zwei Simulationsprogramme wurden verwendet. Mit Hilfe des Wärmeübertrager-Programms wurden die Wärmeübertragungsvorgänge unter Berücksichtigung der Längswärmeleitung simuliert. Hierbei geht die Expansionsarbeit als stationäre Wärmesenke ein. Der im Ergebnis vorliegende stationäre Temperaturverlauf ist die Grundlage für die Berechnung der Expansionsarbeit unter Berücksichtigung der Realgaseigenschaften im Expander-Programm. Für die Neon-Tieftemperaturvariante wurde eine Grundvariante des WE definiert. Anhand dieser wurde mit Hilfe der Programme der Einfluss verschiedener Parameter auf Kälteleistung u. Gütegrad untersucht. Der WE wird als Teil des beschriebenen Prozesses mit einer JT-Stufe betrachtet. Die Kälteleistung weist sowohl in Abhängigkeit vom Massestrom als auch vom Hub ein Maximum auf. Der Shuttle-Verlust verschiebt durch Wärmetransport mittels des Kolbens die effektive Kälteleistung zu kleineren Hüben. Die durch die Güte (NTU) des JT-Wärmeübertragers bestimmte Eintrittstemperatur des Niederdruckstroms in den WE hat einen großen Einfluss auf die Kälteleistung. Mit steigender Eintrittstemperatur steigen der NTU-Wert für den Arbeitsraum u. somit auch die Kälteleistung. Das Maximum der Kälteleistung stimmt nicht mit dem Optimum für den Gütegrad überein. Der Gütegrad strebt mit sinkenden Masseströmen einem Optimum zu. Durch den zunehmenden Einfluss der Längswärmeleitung u. begrenzt durch die Minimalfüllung der Maschine aufgrund des Schadraumes ergibt sich ein Optimum. Der Einfluss des Massestroms ist entscheidend. Als untergeordnete Größen beeinflussen die Eintrittstemperatur des Niederdruckstroms u. der Hub den optimalen Gütegrad. Der Einfluss der Längswärmeleitung auf Kälteleistung u. Gütegrad wird exemplarisch anhand von vergleichenden Rechnungen gezeigt. Konkret kann für einen Eintrittsdruck von 200 bar, einen Austrittsdruck von 60 bar bei einer Eintrittstemperatur des Niederdruckstroms von 80 K für die Grundvariante eine maximale effektive Kälteleistung von 1,3 W mit einem Massestrom von 0,22 g/ s bei einem Hub von ca. 17 mm ausgewiesen werden. Der effektive Gütegrad für diese Bedingungen beträgt ca. 14%. Kommerzielle Split-Stirlingkühler erreichen bei 42 K einstufig Gütegrade von ca. 7%. Mit der vorgeschlagenen Konfiguration wird ein Konzept vorgestellt, das trotz technologisch offener Fragen das Gütegradniveau bekannter Kryokühler übertreffen kann. / Many applications of high temperature superconductivity are working advantageously within a temperature range between 30 K and 50 K. But for this temperature range only few suitable cryocooler with small refrigerating capacity (1-2 W) and good efficiency exist.Due to its properties Neon is an excellent refrigerant for this temperature level as an example with realised Joule-Thomson plant shows. A process analysis results in the presented cycle which is especially adapted to the properties of Neon. By combination of heat exchange and work extracting expansion and integration of a Joule-Thomson stage a high efficiency could be reached in spite of less efficient components.By arranging heat exchanger surfaces into a piston expansion machine a new concept is suggested to produce refrigeration in a large temperature range with a lot of expansion steps with reduced number of expanders. This unit is referred hereinafter to as heat exchanger-expander.The conical shaped working space results in an increase of the heat transfer coefficient and the heat transfer area.Several test machines were investigated. By means of testing the main loss sources and critical zones could be identified. The test results prove the opportunity of a near isothermal expansion and compression for the specified pressure ratio.Options to reduce the axial heat conduction are presented.Two simulation programs were utilised. Using the heat exchanger program the heat transfer is simulated in consideration of the axial heat conduction. Thereby the expansion work is considered as a stationary heat sink. The resulting stationary temperature pattern is the base for the expansion work calculation using the real gas properties in the expander program. Referring to the defined basic neon low temperature application the influence of different parameters on refrigerating capacity and efficiency was researched with the programs. The heat exchanger-expander is part of the described process with a Joule-Thomson stage. The refrigerating capacity shows a maximum depending as well from the mass flow as from the stroke. In result of the shuttle loss smaller strokes lead to better capacity due to heat transport with the piston.The inlet temperature of the low pressure flow influenced by the quality (NTU) of the Joule-Thomson heat exchanger has a large influence on the refrigerating capacity. With increasing inlet temperature the number of transfer units (NTU) for the fluid in the working volume increases and so the refrigerating capacity, too. The location of refrigerating capacity maximum and efficiency optimum is different. While decreasing mass flow efficiency is increasing to an optimum caused by the increased influence of axial heat conduction but limited by the minimum charge of the machine due to the dead space. The influence of the mass flow is dominating. As lower range values the inlet temperature of the low pressure flow and the stroke are influencing the optimal efficiency. The influence of axial heat conduction on refrigerating capacity and efficiency is shown using comparing calculations.For an inlet pressure of 200 bar, an outlet pressure of 60 bar, an inlet temperature of the low pressure flow of 80 K, a mass flow of 0,22 g/ s and a stroke of about 17 mm for the basic version of heat exchanger-expander a maximal effective refrigerating capacity of 1,3 We could be shown. The effective efficiency therefore is 14 %. Current commercial split Stirling cryocooler reach with single stage operation efficiencies of about 7 % at 42 K. The suggested configuration represents a concept that could be able to master the efficiency level of known cryocooler.
7

Performance Optima for Endoreversible Systems

Burzler, Josef Maximilian 28 January 2002 (has links)
Theoretical bounds for performance measures of thermodynamical systems are investigated under conditions of finite times and rates of processes using endoreversible models. These models consist of reversible operating sub-systems which exchange energy via generally irreversible interactions. Analytical and numerical calculations are performed to obtain performance optima and respective optimized process and design parameters for four model systems. A heat engine where the heat transfer between the working fluid and heat reservoirs is described by generalized, polytropic process is optimized for maximum work output. Thermal efficiencies, optimal values for temperatures and process times of the heat transfer processes are determined. A model of a generalized system suited to describe the operation of heat engines, refrigerators, and heat pumps is optimized with respect to thermal efficiency. Several examples illustrate how the results of the analysis are used to allocate financial resources to the heat exchanger inventory in an optimal way. A power-producing thermal system which exchanges heat with several heat reservoirs via irreversible heat transfer processes is analyzed to find the optimal contact times between the working fluid and each of the reservoirs. The piston motion of a Diesel engine is optimized to achieve maximum work for a given amount of fuel. The endoreversible model of the Diesel engine accounts for the temporal variations of the heat produced by the combustion process, the basic flow pattern within the engine's cylinder, the temperature dependence of the viscosity, thermal conductivity, and heat capacity of the working fluid and losses due to friction and heat leak through the cylinder walls. / Theoretische Grenzen für verschiedene Leistungsmerkmale von thermodynamischen Systemen werden unter der Bedingung endlicher Zeiten und Prozessraten im Rahmen endoreversibler Modelle untersucht. Diese Modelle bestehen aus reversiblen Subsystemen, welche über allgemein irreversible Wechselwirkungen Energie austauschen. Analytische und nummerische Berechnungen quantifizieren diese Grenzen und liefern optimale Prozess- und Konstruktionsparameter für vier Modellsysteme. Für eine auf maximale Ausgangsarbeit optimierte Wärmekraftmaschine, bei der die Wärme zwischen Arbeitsmedium und Wärmereservoirs während allgemeiner polytroper Zustandsänderungen des Arbeitsmediums übertragen wird, werden optimale Temperaturen und Zeiten für die Wärmeübertragungsprozesse sowie die thermischen Wirkungsgrade bestimmt. Für ein wirkungsgrad-optimiertes Modell eines verallgemeinerten thermischen Umwandlungssytems, das sowohl Wärmekraftmaschinen, Kühler und Wärmepumpen beschreibt, wird die optimale Verteilung von Investitionskosten auf die Wärmetauscher ermittelt und die Anwendung der allgemeingültigen Ergebnisse anhand mehrerer Beispiele demonstriert. Für eine Wärmekraftmaschine mit mehreren Wärmereservoirs wird bestimmt, welche der Wärmereservoirs wie lange kontaktiert werden müssen, um eine maximale Ausgangsarbeit zu erzielen. Für einen Dieselmotor wird die Kolbenbewegung so optimiert, dass bei gegebener Treibstoffmenge eine maximale Ausgangsarbeit erzielt wird. Das endoreversible Modell des Dieselmotors berücksichtigt die Temperaturabhängigkeit der Wärmekapazität, Wärmeleitfähigkeit und Viskosität des Arbeitsfluids, die Zeitabhängigkeit des Verbrennungsprozesses sowie Reibungs- und Wärmeverluste.