• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 74
  • 67
  • 15
  • 11
  • 4
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 218
  • 63
  • 58
  • 34
  • 31
  • 21
  • 20
  • 18
  • 16
  • 15
  • 14
  • 14
  • 13
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Trois applications d'une approche géométrique à la théorie conforme des champs / Three applications of a geometric approach to conformal field theory

Tauber, Clément 01 December 2015 (has links)
La thèse, composée de trois parties, est consacrée à des problèmes physiques différents reliés à la Théorie Conforme des Champs (CFT) bidimensionnelle. La première partie s'intéresse aux propriétés de transport hors d'équilibre à travers une jonction de fils quantiques. Trois modèles y sont étudiés. Le premier décrit les fils par un champs bosonique libre compactifié vu comme la bosonisation du liquide de Luttinger d'électrons. La jonction des fils est modélisée par une condition limite assurant la diffusion non triviale des charges entre les fils. Associant la quantification canonique et l'intégrale fonctionnelle, on calcule exactement les fonctions de corrélation des courants dans l'état d'équilibre du modèle, mais aussi dans un état stationnaire hors d'équilibre, ainsi que la statistique complète de comptage pour les transferts de charge et d'énergie entre les fils maintenus en températures et potentiels différents. Les deux autres modèles d'une jonction de fils quantiques sont basés sur la théorie de Wess-Zumino-Witten (WZW). Dans le premier, la jonction est décrite par une "brane cyclique" et dans le deuxième, par une "brane coset". Les résultats dans le premier cas sont aussi complets que pour le champ libre, mais les charges y sont entièrement transmises d'un fils au suivant. Dans le deuxième cas, la diffusion des charges n'est pas triviale, mais le modèle se révèle difficile à résoudre. La deuxième partie de la thèse étudie les anomalies globales de jauge dans les modèles "coset" de CFT réalisés comme la théorie WZW jaugée. La classifications (presque) complète de telles anomalies, lesquelles rendent certains modèles coset inconsistants, est présentée. Elle emploie la classification des sous-algèbres des algèbres de Lie simples due à Dynkin. Finalement, la troisième partie de la thèse décrit la construction géométrique d'indice des familles d'opérateurs unitaires obtenues des projecteurs sur les bandes de valence d'un isolant topologique bidimensionnel invariant par renversement du temps. L'indice construit est relié d'un côté à la racine carrée de l'amplitude de Wess-Zumino d'une telle famille, et, de l'autre, il reproduit l'invariant de Kane-Mele de l'isolant. La dernière identification exige un argument complexe qui exploite une nouvelle anomalie de jauge pour les modèles WZW à bord. Les trois parties de la thèse emploient des outils géométriques de CFT assez semblables, permettant d'obtenir toute une série des résultats originaux. Cette unité de méthode, ainsi que le thème des anomalies, constituent le trait d'union entre les différents composants du manuscrit. / The thesis, consisting of three parts, is focusing on different physical problems that are related to two dimensional Conformal Field Theory (CFT).The first part deals with nonequilibrium transport properties across a junction of quantum wires. Three models are studied. The first one describes the wires by a free compactified bosonic field, seen as the bosonization of the Luttinger liquid of electrons. The junction of the wires is modeled by a boundary condition that ensures nontrivial scattering of the charges between the wires. Combining canonical quantization and functional integral, we compute exactly the current correlation functions in equilibrium, but also in a nonequilibrium stationary state, as well as the full counting statistics of charge and energy between the wires set at different temperatures and potentials. The two other models of quantum wire junction are based on Wess-Zumino-Witten theory (WZW). In the first one, the junction is described by a “cyclic brane” and in the second, by a “coset brane”. The results in the first case are as complete as for the free field, but the charges are fully transmitted from one wire to the next one. In the second case, the scattering is nontrivial, but the model turns out to be difficult to solve.The second part of the thesis studies the global gauge anomalies in “coset” models of CFT, realized as gauged WZW theories. The (almost) complete classification of such anomalies, that lead to some inconsistent coset models, is presented. It is based on Dynkin classification of subalgebras of simple Lie algebras.Finally, the third part of the thesis describes the geometric construction of index from unitary operator families obtained from valence band projectors of a two-dimensional time-reversal invariant topological insulator. The index is related on one hand to the square root of the Wess-Zumino amplitude of such a family, and, on the other hand, it reproduces the Kane-Mele invariant of the insulator. The last identification requires a nontrivial argument that uses a new gauge anomaly of WZW models with boundary.The three parts of the thesis use similar geometrical tool of CFT, that permits to obtain several original results. The unity in the method, as well as the topic of anomalies, builds a bridge between the different components of the manuscript.
132

Avaliação da resistência à fadiga e corrosão-fadiga da armadura de tração de um riser flexível retirado de operação

Negreiros, Luiz Antonio Sulino de January 2016 (has links)
Risers flexíveis são comumente utilizados como parte de sistemas submarinos de produção de petróleo, sendo caracterizados por uma estrutura tubular multicamadas. Durante a instalação ou operação, estes risers podem estar sujeitos a eventos externos que podem vir a causar avarias na sua camada externa. Neste sentido, em alguns casos, faz-se necessária a reavaliação da vida em fadiga destes risers, por estarem operando numa condição diferente daquela inicialmente prevista no projeto como, por exemplo, quando o espaço anular do riser configura um ambiente corrosivo. Este trabalho avalia, por meio de teste de fadiga e corrosão-fadiga, o efeito causado pela alteração da superfície corroída na resistência à fadiga de aços de armaduras de tração de um riser retirado do campo. A corrosão se deu pelo contato da água do mar com as armaduras devido a um dano na capa externa. A intensidade da corrosão e sua relação com a vida à fadiga foram avaliadas em duas regiões do riser, sendo uma no local do dano (ruptura da capa externa) e outra 5 metros afastada do mesmo. Por meio de medidas de rugosidade e análise por imagem, verificou-se que a corrosão na região afastada foi, em geral, da ordem de 30% inferior à observada na região do dano. Após avaliação da corrosão dos arames das duas regiões, procedeu-se com os testes de fadiga e corrosão-fadiga em escala reduzida. Os resultados mostraram que, apesar da diferença na corrosão, as duas regiões apresentaram desempenho similares à fadiga ao ar. Além disso, quando comparado com dados de arames íntegros de referência, os arames corroídos tiveram uma considerável redução da resistência à fadiga nos testes ar e corrosão-fadiga, evidenciando o efeito deletério dos pites de corrosão pré-existentes, mesmo com tamanhos reduzidos. A partir das medidas de profundidades e diâmetros dos pites e com uso de modelos teóricos, foram feitas estimativas dos fatores de concentração de tensões à fadiga, Kf, sendo encontrados valores próximos ao valor obtido experimentalmente. Com base nos resultados dos testes realizados, este trabalho contribuiu com importantes dados sobre a influência da pré-corrosão no desempenho à fadiga de arames, os quais podem subsidiar o processo de reavaliação de vida à fadiga de risers flexíveis e também discussões sobre as atuais metodologias de testes de corrosão-fadiga. / Flexible risers are commonly used as part of subsea production systems in oil and gas industry and they are characterized by multilayer tubular structure. During installation or operation, these risers may be subjected to external events that might cause damages to the outer sheath. Therefore, in some cases, it is necessary to reevaluate the fatigue life of these risers because they are operating in different conditions from that originally expected in the design phase, for instance, when the flexible pipe designed for intact annulus have the outer sheath breached. By using fatigue and corrosion fatigue testing, this study evaluates the corroded surface effect on the fatigue resistance of carbon steel tensile armor removed from service. The corrosion occurred due to a damage at the riser outer sheath, which exposed the armors to the seawater. The corrosion intensity and its association to the fatigue resistance were evaluated at two regions of the riser, one at the outer sheath damage and another 5 meters away from the breach. By using roughness measurements and image analysis, it was found corrosion approximately 30% lower at the away location when compared to the damage region. After corrosion evaluation, small scale fatigue and corrosion-fatigue tests were conducted. The results showed that, despite the significant difference in corrosion, both regions presented similar fatigue life in ar. In addition, when compared to intact wires from reference data, the corroded wires had a fatigue resistance reduction for tests in both air and corrosive mean, demonstrating the detrimental effect of pre-existing corrosion pits. From the pits depths and diameters along with theoretical models, fatigue notch factors were estimated and the values were quite close to the one obtained experimentally. Based on tests results, this study contributes with important data about the influence of pre-corrosion in fatigue performance of wires, which can support the process of fatigue life reevaluation for flexible risers and discussions on current methodologies used for corrosion-fatigue tests.
133

Avaliação das forças, momentos e binding, produzidos por deformação de primeira ordem do fio NiTi .014 superelástico, em braquetes autoligáveis passivos estudo in vitro / Evaluation of force, moment and binding produced by first order deformation on a superelastic .014 Niti wire using passive self-ligated brackets in vitro study

Queiroz, Gilberto Vilanova 09 April 2010 (has links)
Os efeitos mecânicos exercidos sobre os dentes pela deformação do fio de níqueltitânio dependem de sua rigidez e das características dos braquetes. Os fatores associados ao braquete são a largura, que influencia o comprimento de fio interbraquetes e o coeficiente de atrito. O objetivo desta pesquisa foi comparar a influência dos braquetes autoligáveis passivos Damon, Easy Clip e Smart Clip, sobre as forças, momentos e binding produzidos pela deformação do fio Contour NiTi .014. Metodologia: um dispositivo de simulação clínica com 3 braquetes .022x.028 de aço, correspondentes ao canino e pré-molares, foi acoplado à maquina de tração universal Instron para registro das forças e ao dinamômetro Lutron para registro dos momentos na unidade de ancoragem. A deformação de primeira ordem do fio superelástico Contour NiTi .014 foi propiciada pelo deslocamento do braquete do primeiro pré-molar fixo à máquina Instron. Foi utilizada célula de carga de 500 Newtons e velocidade de 0,05mm/segundo durante a deformação. As forças e momentos foram registrados até deslocamento máximo de 4,5 mm e durante retorno à zero. Foram realizadas dez repetições para cada modelo de braquete. O registro do binding foi obtido em teste separado por meio da tração contínua do fio Contour NiTi durante deformação de primeira ordem até 4,8 mm e retorno até zero. Os efeitos mecânicos foram comparados com deformação de 4 mm. Resultados: na unidade de movimentação as forças de ativação apresentaram diferenças significantes (Damon 224, Easy Clip 241 e Smart Clip 299 cN) enquanto as forças de desativação foram menores no Damon (62 Cn) e semelhantes entre os braquetes Easy Clip (71 cN) e Smart Clip (76 Cn). Na unidade de ancoragem os momentos de ativação apresentaram diferenças significantes (Damon 314, Easy Clip 356 e Smart Clip 438 cN/mm) enquanto os momentos de desativação foram semelhantes entre os braquetes Damon e Easy Clip (239/242 cN/mm) e significativamente maiores no Smart Clip (317 cN/mm). Os valores de binding na ativação e desativação foram semelhantes. O percentual de histerese das forças foi 70% e dos momentos 28%. Conclusões: 1) as forças de desativação produzidas pelo fio Contour NiTi .014 foram semelhantes, o que indicou equivalência mecânica entre os braquetes Damon, Easy Clip e Smart Clip na unidade de movimentação; 2) os momentos de desativação produzidos pelo fio Contour NiTi .014 foram semelhantes entre os braquetes Damon e Easy Clip, e maiores no Smart Clip, o que indicou equivalência mecânica apenas entre os braquetes Damon e Easy Clip na unidade de ancoragem ; 3) a medição das forças de atrito por meio da tração contínua do fio ortodôntico não se mostrou adequada para medir o binding associado à força de desativação; 4) a histerese acentuada observada no início da desativação das forças foi influenciada pela superelasticidade do fio e pelo binding na unidade de ancoragem. / Bracket characteristics and wire stiffness dictate the mechanical effects that nickel titanium wire deformation will cause upon teeth. The main variables associated to bracket characteristics include bracket length (that influence interbracket distance), and coefficient of friction. The purpose of this research was to compare how self ligated brackets such as Damon, Easy Clip and Smart Clip influence moments, forces, and binding produced by the deformation of a .014 Niti Contour wire. Methods: a clinical simulation device with three .022x.028 stainless steel brackets representing canine and bicuspids was attached to an Instron universal traction machine in order to register the forces, and to a Lutron dynamometer to register the moments produced on the anchor unit. The displacement of the first bicuspid fixed on the Instron machine produced a first order deformation on the superelastic .014 Niti Contour wire. A load cell of 500 Newtons under a speed of 0,05mm/second was used during the deformation. Forces and moments were registered up to 4,5mm maximum displacement and during the return to zero. For each bracket model ten repetitions were performed. Binding registration was obtained on a separate test, by continuous traction of the Contour Niti wire during first order deformation up to 4,8mm and back to zero. The mechanical effects were compared with a 4mm deformation. Results: on the moving unit, the activation forces presented significant differences (Damon 224, Easy Clip 241 and Smart Clip 299cN), while the deactivation forces were smaller on Damon (62cN) and similar on the Easy Clip (71cN) and Smart Clip (76 cN). The activation moments on the anchor unit presented significant differences (Damon 314, Easy Clip 356 and Smart Clip 438 cN/mm), while the deactivation moments were similar in the Damon (239 cN/mm) and Easy Clip (242 cN/mm) brackets, and significantly larger on Smart Clip (317cN/mm). Activation and deactivation binding values were similar. The hysteresis percentage on forces was 70% and on moments 28%. Conclusions: 1) the forces produced by the .014 Contour Niti at the movement unit are similar among the Damon, Easy Clip and Smart Clip brackets; 2) the moments produced by the .014 Contour Niti at the anchor unit are similar between Damon and Easy Clip brackets, while the Smart Clip produces larger moments; 3) the method of measuring friction forces by continuous traction of the orthodontic wire is not adequate to measure the binding associated with deactivation forces; 4) hysteresis observed at the beginning of deactivation is influenced by binding.
134

Avaliação da resistência ao deslocamento na sobreposição de fios de níquel e titânio superelásticos termoativados em braquetes autoligáveis passivos / Assessment of the displacement resistance of overlapped heat-activated superelastic nickel titanium wires in passive self-ligating brackets

Galvão, Mariana de Aguiar Bulhões 22 August 2014 (has links)
Objetivos: O objetivo desta pesquisa foi comparar a resistência ao deslocamento de fios de níquel e titânio superelásticos termoativados sobrepostos, em braquetes ortodônticos metálicos autoligáveis passivos. Material e Métodos: Foram utilizadas três espessuras de fios de níquel e titânio superelásticos termoativados (NiTi-TA): 0,014 sobreposto ao 0,016 e 0,020 (FlexyNiTi Thermal - Orthometric, Marília, SP, BR), associados a dois tipos de braquetes metálicos autoligáveis passivos: SmartClip SL3® (3M Unitek, Monrovia, CA, EUA) e OrthoClip SLB® (Orthometric, Marília, SP, BR). Um dispositivo que continha 5 braquetes de cada tipo (do incisivo central superior direito ao 2º pré-molar superior direito) foi desenvolvido para realização dos testes. O braquete do canino foi colado em uma barra de aço inoxidável móvel que permitia alterar sua posição vertical, enquanto os demais braquetes foram colados a uma barra fixa de acrílico. As forças obtidas por meio do deslocamento vertical do braquete do canino de 0mm para 1,5mm, 3,0 mm, 4,5mm e 6,0 mm foram registradas. O ambiente de teste foi seco com temperatura controlada de 36,5º C ± 1º C. Um total de 160 testes foi realizado na máquina de ensaios universal Instron. Os testes estatísticos de Shapiro-Wilk, teste t de Student não pareado e ANOVA com testes post-hoc de Tukey foram aplicados aos dados (p<0,05). Resultados: A distribuição normal da amostra foi confirmada, e os testes paramétricos demonstraram que houve diferenças estatisticamente significativas no braquete SmartClip SL3® quando associados aos fios de NiTi-TA 0,020 e 0,014 sobreposto ao 0,016 nas alturas de 1,5mm (p=0,003) e 6mm (p0,0001). Porém, não foram encontradas diferenças estatísticas nas alturas de 3mm (p=0,76) e 4,5mm (p=0,09). No braquete OrthoClip SLB® houve diferenças estatisticamente significativas entre os fios de NiTi-TA 0,020 e 0,014 sobreposto ao 0,016 em todas as alturas avaliadas (p0,0001). Na comparação entre os braquetes, quando associados ao fio 0,020 de NiTi-TA houve diferenças estatisticamente significativas na altura de 1,5mm; 3mm e 6mm (p0,0001). No entanto, na altura de 4,5mm as diferenças não foram significativas estatisticamente (p=0,32). Quando associados aos fios de NiTi-TA 0,014 e 0,016 sobrepostos, as diferenças em todas as alturas avaliadas foram significativas estatisticamente (1,5mm - p=0,0006; nas demais alturas p0,0001). Conclusão: Nos braquetes SmartClip SL3®, em desnivelamentos de 1,5mm, os fios de NiTi-TA 0,014 e 0,016 sobrepostos apresentaram menor resistência ao deslocamento, enquanto que na altura de 6mm a menor resistência foi obtida com o fio de NiTi-TA 0,020. Nas demais alturas não houve diferenças estatísticas entre os fios. Para os braquetes OrthoClip SLB®, os fios de NiTi-TA 0,014 e 0,016 sobrepostos apresentaram menor resistência ao deslocamento em todas as alturas avaliadas. Na comparação entre os dois tipos de braquetes, associados ao fio de NiTi-TA 0,020 na altura de 1,5mm, o braquete OrthoClip SLB® apresentou menor resistência ao deslocamento, ao passo que nas alturas de 3mm e 6mm foi o braquete SmartClip SL3®. Na altura de 4,5mm não foram encontradas diferenças estatisticamente significativas entre os dois braquetes avaliados. / Objective: The objective of this research was to compare the displacement resistance of overlapped heat-activated superelastic nickel titanium wires, in passive self-ligating metallic brackets. Material and Methods: Three thicknesses of heat-activated superelastic nickel titanium wires (NiTi-TA) were used: 0.014 overlapped with 0.016 and 0.020 (FlexyNiTi Thermal - Orthometric, Marília, SP, BR), associated with two types of passive self-ligating metallic brackets: SmartClip SL3® (3M Unitek, Monrovia, CA, EUA) and OrthoClip SLB® (Orthometric, Marília, SP, BR). A device with 5 brackets of each type (from right central incisor to the second maxillary premolar) was developed for this research. The canine bracket was attached to a sliding stainless steel bar which allowed the alteration of its vertical position, while the remaining brackets were attached to a fixed acrylic bar. The forces generated by means of the canine bracket vertical displacement from 0mm to 1.5mm; 3.0mm; 4.5mm and 6.0mm were recorded. The test environment was dry with a controlled temperature of 36.5º C ± 1º C. A total of 160 tests were carried out in the Instron Testing Machine. The Shapiro-Wilk test, non-paired Student t-test and ANOVA with Tukey post hoc test were applied to the data (p<0.05). Results: The normal distribution was confirmed, and the parametric tests showed that there were statistically significant differences in the SmartClip SL3® when associated with the NiTi-TA 0.020 and 0.014 wires overlapped to the 0.016 wire in the height of 1.5mm (p=0.003) and 6mm (p<0.0001). However, statistically significant differences were not found in the heights of 3mm (p=0.76) and 4.5mm (p=0.09). For the OrthoClip SLB® brackets, there were statistically significant differences between the NiTi-TA 0.020 and 0.014 wires overlapped with the 0.016 wire in all the heights assessed (p<0.0001). In the comparison between the brackets when associated with the NiTi-TA 0.020 wire, there were statistically significant differences in the heights of 1.5mm, 3mm and 6mm (p<0.0001). However, in the height of 4.5mm the differences were not statistically significant (p=0.32). When associated with the overlapped NiTi-TA 0.014 and 0.016 wires, the differences in all assessed heights were statistically significant (1.5mm - p=0.0006; other height - p0.0001). Conclusion: For the SmartClip SL3® brackets, with 1.5mm of displacement, the overlapped NiTi-TA 0.014 and 0.016 wires showed less displacement resistance, while in the height of 6mm the least displacement resistance was found with the NiTi-TA 0.020. In the remaining heights, there were no statistically significant differences between the wires. For the OrthoClip SLB® brackets, the overlapped NiTi-TA 0.014 and 0.016 wires showed the least displacement resistance in all the assessed heights. In the comparison between the two types of brackets, associated with the NiTi-TA 0.020 wire, for the height of 1.5mm, the OrthoClip SLB® bracket showed less displacement resistance, while for the heights of 3mm and 6mm the SmartClip SL3® brackets showed less displacement resistance. For the height of 4.5mm there were no statistically significant differences found between the assessed brackets.
135

Quantum transport and spin effects in lateral semiconductor nanostructures and graphene

Evaldsson, Martin January 2008 (has links)
This thesis studies electron spin phenomena in lateral semi-conductor quantum dots/anti-dots and electron conductance in graphene nanoribbons by numerical modelling. In paper I we have investigated spin-dependent transport through open quantum dots, i.e., dots strongly coupled to their leads, within the Hubbard model. Results in this model were found consistent with experimental data and suggest that spin-degeneracy is lifted inside the dot – even at zero magnetic field. Similar systems were also studied with electron-electron effects incorporated via Density Functional Theory (DFT) in the Local Spin Density Approximation (LSDA) in paper II and III. In paper II we found a significant spin-polarisation in the dot at low electron densities. As the electron density increases the spin polarisation in the dot gradually diminishes. These findings are consistent with available experimental observations. Notably, the polarisation is qualitatively different from the one found in the Hubbard model. Paper III investigates spin polarisation in a quantum wire with a realistic external potential due to split gates and a random distribution of charged donors. At low electron densities we recover spin polarisation and a metalinsulator transition when electrons are localised to electron lakes due to ragged potential profile from the donors. In paper IV we propose a spin-filter device based on resonant backscattering of edge states against a quantum anti-dot embedded in a quantum wire. A magnetic field is applied and the spin up/spin down states are separated through Zeeman splitting. Their respective resonant states may be tuned so that the device can be used to filter either spin in a controlled way. Paper V analyses the details of low energy electron transport through a magnetic barrier in a quantum wire. At sufficiently large magnetisation of the barrier the conductance is pinched off completely. Furthermore, if the barrier is sharp we find a resonant reflection close to the pinch off point. This feature is due to interference between a propagating edge state and quasibond state inside the magnetic barrier. Paper VI adapts an efficient numerical method for computing the surface Green’s function in photonic crystals to graphene nanoribbons (GNR). The method is used to investigate magnetic barriers in GNR. In contrast to quantum wires, magnetic barriers in GNRs cannot pinch-off the lowest propagating state. The method is further applied to study edge dislocation defects for realistically sized GNRs in paper VII. In this study we conclude that even modest edge dislocations are sufficient to explain both the energy gap in narrow GNRs, and the lack of dependance on the edge structure for electronic properties in the GNRs.
136

A cone-beam computerized tomography evaluation of anterior root resorption comparing SureSmile® and conventional edgewise treatments

Patel, Neepa. January 2009 (has links) (PDF)
Thesis--University of Oklahoma. / Bibliography: leaves 120-128.
137

Fadiga de fios superelásticos de liga com memória de forma NI-TI em regime de flexão alternada: uma análise usando planejamento fatorial.

ARAÚJO, Magna Silmara de Oliveira. 15 June 2018 (has links)
Submitted by Emanuel Varela Cardoso (emanuel.varela@ufcg.edu.br) on 2018-06-15T19:15:40Z No. of bitstreams: 1 MAGNA SILMARA DE OLIVEIRA ARAÚJO – DISSERTAÇÃO (PPG-CEMat) 2016.pdf: 3448861 bytes, checksum: b9341836ea322c6702a8fe974682fc68 (MD5) / Made available in DSpace on 2018-06-15T19:15:40Z (GMT). No. of bitstreams: 1 MAGNA SILMARA DE OLIVEIRA ARAÚJO – DISSERTAÇÃO (PPG-CEMat) 2016.pdf: 3448861 bytes, checksum: b9341836ea322c6702a8fe974682fc68 (MD5) Previous issue date: 2016-08-18 / Capes / As Ligas com Memória de Forma (LMF) pertencem a uma classe de ligas metálicas que possuem características funcionais únicas de Efeito Memória de Forma (EMF) e Superelasticidade (SE). As LMF do sistema Ni-Ti são as mais difundidas no mercado e podem ser encontradas em diversas aplicações que abrangem, principalmente, os campos de medicina e odontologia. No entanto, muitas destas aplicações acontece sob solicitações cíclicas ou variáveis, o que torna imprescindível o estudo da vida em fadiga destes tipos de materiais. Diante disto, o presente trabalho tem como objetivo analisar o comportamento em fadiga de fios superelásticos de LMF Ni-Ti com seção transversal circular e retangular, submetidos a ensaios dinâmicos em modo de flexão simples (Single Cantilever) utilizando um equipamento de Análise DinâmicoMecânica (DMA - Dynamic Mechanical Analysis). A vida em fadiga dos fios Ni-Ti foi avaliada por meio do número de ciclos até a ruptura em função das amplitudes de deformação aplicadas durante o processo de ciclagem mecânica. Adicionalmente, a fadiga funcional foi avaliada por meio do acompanhamento da evolução da força aplicada em função do número de ciclos para diferentes amplitudes de deformação (0,7; 1,0; 1,3 e 1,6%) e níveis diferentes de frequê ncia de carregamento (0,5 e 1,0Hz). A influência simultânea da amplitude de deformação e frequência de carregamento sob a vida em fadiga dos fios foi avaliada através de um Planejamento Fatorial. Observou-se, em geral, que a força sofre um leve aumento, de aproximadamente 5%, durante os primeiros ciclos, tendendo a se estabilizar e permanecendo praticamente constante até iniciar um decaimento devido ao processo de ruptura cíclica. Constatou-se também, através das curvas de Wöhler, que o fio de seção circular possui uma vida em fadiga superior àquela do fio de seção retangular. O Planejamento fatorial utilizado permitiu a obtenção de modelos estatísticos significativos e bem ajustados. Além disso, o número de ciclos até a fratura dos fios Ni-Ti depende de forma direta da amplitude de deformação cíclica e da frequência de ensaio, situando-se na faixa de 103 a 105 ciclos, caracterizando uma fadiga de baixo ciclo. / Shape Memory Alloys (SMA) belong to a class of metallic alloys that have unique functional characteristics: Shape Memory Effect (SME) and Superelasticity (SE). The Ni-Ti SMA system are the most widespread in the market and can be found in diverse applications covering mainly medical and odontology. However, many of these applications takes place under cyclic or variables loads, which makes it necessary to study the fatigue life of these materials. Therefore, the present study aims to analyze the fatigue behavior of Ni-Ti SMA superelastic wires with circular and rectangular, cross sections subjected to dynamic tests in simple bending mode (Single Cantilever) using a Dynamic Mechanical Analysis (DMA) equipment. The fatigue life of the Ni-Ti wires was evaluated by the number of cycles until break as a function of applied strain amplitudes during the mechanical cycling process. In addition, functional fatigue was assessed by monitoring the evolution of the applied force on the number of cycles for different deformation amplitudes (0.7, 1.0, 1.3 and 1.6%) and different levels of frequency loading (0.5 and 1.0Hz). The simultaneous influence of strain amplitude and frequency on fatigue life of the wires was assessed through a factorial design. It was observed generally that the strength under goes a slight increase of approximately 5% during the first cycles, tending to stabilize and remained virtually constant until starting a cyclic decay due to rupture process. It was also observed by means of Wöhler curves, that circular section wires has a higher fatigue life to that of the rectangular wires. The factorial design used allowed to obtain significant statistical models, predictive and well adjusted. Furthermore, the number of cycles to failure of the Ni-Ti wires depends directly of the cyclic strain amplitude and frequency of testing, to stand in the range 103 -105 cycles, characterizing a low cycle fatigue.
138

Avaliação da resistência à fadiga e corrosão-fadiga da armadura de tração de um riser flexível retirado de operação

Negreiros, Luiz Antonio Sulino de January 2016 (has links)
Risers flexíveis são comumente utilizados como parte de sistemas submarinos de produção de petróleo, sendo caracterizados por uma estrutura tubular multicamadas. Durante a instalação ou operação, estes risers podem estar sujeitos a eventos externos que podem vir a causar avarias na sua camada externa. Neste sentido, em alguns casos, faz-se necessária a reavaliação da vida em fadiga destes risers, por estarem operando numa condição diferente daquela inicialmente prevista no projeto como, por exemplo, quando o espaço anular do riser configura um ambiente corrosivo. Este trabalho avalia, por meio de teste de fadiga e corrosão-fadiga, o efeito causado pela alteração da superfície corroída na resistência à fadiga de aços de armaduras de tração de um riser retirado do campo. A corrosão se deu pelo contato da água do mar com as armaduras devido a um dano na capa externa. A intensidade da corrosão e sua relação com a vida à fadiga foram avaliadas em duas regiões do riser, sendo uma no local do dano (ruptura da capa externa) e outra 5 metros afastada do mesmo. Por meio de medidas de rugosidade e análise por imagem, verificou-se que a corrosão na região afastada foi, em geral, da ordem de 30% inferior à observada na região do dano. Após avaliação da corrosão dos arames das duas regiões, procedeu-se com os testes de fadiga e corrosão-fadiga em escala reduzida. Os resultados mostraram que, apesar da diferença na corrosão, as duas regiões apresentaram desempenho similares à fadiga ao ar. Além disso, quando comparado com dados de arames íntegros de referência, os arames corroídos tiveram uma considerável redução da resistência à fadiga nos testes ar e corrosão-fadiga, evidenciando o efeito deletério dos pites de corrosão pré-existentes, mesmo com tamanhos reduzidos. A partir das medidas de profundidades e diâmetros dos pites e com uso de modelos teóricos, foram feitas estimativas dos fatores de concentração de tensões à fadiga, Kf, sendo encontrados valores próximos ao valor obtido experimentalmente. Com base nos resultados dos testes realizados, este trabalho contribuiu com importantes dados sobre a influência da pré-corrosão no desempenho à fadiga de arames, os quais podem subsidiar o processo de reavaliação de vida à fadiga de risers flexíveis e também discussões sobre as atuais metodologias de testes de corrosão-fadiga. / Flexible risers are commonly used as part of subsea production systems in oil and gas industry and they are characterized by multilayer tubular structure. During installation or operation, these risers may be subjected to external events that might cause damages to the outer sheath. Therefore, in some cases, it is necessary to reevaluate the fatigue life of these risers because they are operating in different conditions from that originally expected in the design phase, for instance, when the flexible pipe designed for intact annulus have the outer sheath breached. By using fatigue and corrosion fatigue testing, this study evaluates the corroded surface effect on the fatigue resistance of carbon steel tensile armor removed from service. The corrosion occurred due to a damage at the riser outer sheath, which exposed the armors to the seawater. The corrosion intensity and its association to the fatigue resistance were evaluated at two regions of the riser, one at the outer sheath damage and another 5 meters away from the breach. By using roughness measurements and image analysis, it was found corrosion approximately 30% lower at the away location when compared to the damage region. After corrosion evaluation, small scale fatigue and corrosion-fatigue tests were conducted. The results showed that, despite the significant difference in corrosion, both regions presented similar fatigue life in ar. In addition, when compared to intact wires from reference data, the corroded wires had a fatigue resistance reduction for tests in both air and corrosive mean, demonstrating the detrimental effect of pre-existing corrosion pits. From the pits depths and diameters along with theoretical models, fatigue notch factors were estimated and the values were quite close to the one obtained experimentally. Based on tests results, this study contributes with important data about the influence of pre-corrosion in fatigue performance of wires, which can support the process of fatigue life reevaluation for flexible risers and discussions on current methodologies used for corrosion-fatigue tests.
139

Análise experimental e numérica de escoamentos turbulentos em canais compostos empregando simulação de grandes escalas e método dos elementos finitos / Experimental and numerical analysis of turbulent flows in compound channels employing large eddy simulation and the finite element method

Xavier, Carla Marques January 2013 (has links)
Este trabalho apresenta um estudo experimental e numérico de escoamentos em canais compostos. Simulação de grandes escalas e método dos elementos finitos, em paralelo com medições utilizando anemômetros de fio quente em um canal aerodinâmico são realizadas. Canais compostos estão presentes em muitas aplicações de engenharia. Dispositivos eletrônicos, trocadores de calor, reatores nucleares, canais de irrigação e planícies de inundação são alguns dos desafios enfrentados pela engenharia. A combinação de simulação de grandes escalas e o método dos elementos finitos para a investigação de escoamentos turbulentos pode ser de grande importância para o estudo dos escoamentos na engenharia. No caso dos escoamentos através dos canais compostos, publicações neste tema são ainda raros. Os principais objetivos deste trabalho são: analisar o escoamento de um fluido viscoso, incompressível e isotérmicas em um canal composto, empregando um código de computação tridimensional apresentado por Petry em 2002, que realiza simulação de grandes escalas com o método dos elementos finitos, para comparar os resultados numéricos com os resultados experimentais do escoamento turbulento em um canal composto cuja geometria é exactamente reproduzida pela malha numérica, para verificar a validade do método numérico e o comportamento de modelos em escala subgrade para reproduzir o fluxo no canal composto investigado; e comparar a eficácia dos esquemas Taylor-Galerkin e dois passos para analisar os resultados. O canal investigado consiste em um canal principal com seção transversal retangular, conectado a uma fenda retangular estreita. No código numérico, o modelo clássico de Smargorinsky é comparado com o modelo dinâmico de viscosidade turbulenta, inicialmente proposto por Germano et al. 1991. A segunda filtragem do processo dinâmico é feita através dos elementos finitos independentes propostos por Petry, 2002. Para a implementação do algoritmo, o método dos elementos finitos é usado, Taylor-Galerkin e esquemas dois passos são usados para a discretização no tempo e no espaço e de ligação das equações governantes. O domínio computacional é discretizadas por intermédio de elementos lineares hexaédricos. Os resultados obtidos a partir simulações de grandes escalas, usando o modelo clássico de Smagorinsky e o modelo dinâmico de submalha; mostram o desenvolvimento de uma camada de cisalhamento na direção principal do escoamento com características dinâmicas regidas pelos perfis de velocidade média. Os resultados da simulação mostraram boa concordância com os dados experimentais dos perfis de velocidade média, intensidade de turbulência e tensão de cisalhamento turbulenta. Em geral, o modelo dinâmico com o esquema de duis passos foi mais eficiente para reproduzir estruturas turbulentas, em comparação com o modelo Smagorinsky e o esquema Taylor-Galerkin particularmente ao longo da região da fenda do canal. / This work presents an experimental and numerical study of turbulent flows in compound channels. Large eddy simulation and finite element method in parallel with hot wires measurements in an aerodynamic channel are employed. Compound channels are present in many engineering applications like in electronic devices, heat exchangers, nuclear reactors and irrigation channels and flooding plains are some of the challenges faced by mechanical engineering. The combination of large eddy simulation and the finite element method for the investigation of turbulent flows can be of great relevance to the study of engineering flows. In the case of flows through compound channels, publications in this subject are still rare. The main objectives in this work are: to analyze the flow of viscous, incompressible and isothermal fluids in a compound channel; employing a three-dimensional computation code presented by Petry, 2002, which performs large eddy simulation with the finite element method; to compare the numerical results with experimental results of the turbulent flow in a compound channel whose geometry is exactly reproduced by the numerical mesh; to check the validity of the numerical method and the behavior of subgrid scale models to reproduce the flow in the compound channel investigated and compare the efficacy of the Taylor-Galerkin and Two-Steps schemes in analyzing the results. The compound channel investigated consists of a rectangular channel connected to a rectangular shaped slot. In the numerical code, Smargorinsky´s classical model is compared to the dynamic model of turbulent viscosity, initially proposed by Germano et al. The second filtering of the dynamic process is made through the independent finite elements proposed by Petry, 2002. For the implementation of the algorithm, the finite element method is used, Taylor- Galerkin and Two-Steps schemes are used for discretization in time and space and to link governing equations. The computational domain is discretized by means of linear hexahedrical elements. The results obtained from large eddy simulations, using the classical model of Smagorinsky and the Dynamic subgrid scale model show the development of a shear layer in the main direction of flow with dynamic characteristics governed by the mean velocity profiles. The simulation results showed good agreement compared to experimental data, and analysis of the profiles of mean velocity, turbulence intensities and turbulent shear stress. In general, dynamic model with the two-steps scheme was more able to reproduce turbulent structures in comparison with the Smagorinsky model with Taylor-Galerkin scheme, particularly along the channel slot.
140

Propriedades físico-químicas de bráquetes e fios ortodônticos utilizados em diferentes tempos de tratamento

Ramos, Aretha Aliny dos Santos 18 February 2014 (has links)
Submitted by Maike Costa (maiksebas@gmail.com) on 2017-03-16T12:14:26Z No. of bitstreams: 1 arquivototal.pdf: 1679756 bytes, checksum: 5065ecafba4b6ac4c0113ddd5cc81002 (MD5) / Made available in DSpace on 2017-03-16T12:14:26Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 1679756 bytes, checksum: 5065ecafba4b6ac4c0113ddd5cc81002 (MD5) Previous issue date: 2014-02-18 / OBJECTIVE: The focus of this study was to test the hypothesis that treatment time and oral pH had an influence on the physical chemical properties of orthodontic brackets and arch wires. METHODS: 120 metal brackets were evaluated. They were divided into 4 groups (n=30): Group C (Control) and Groups T12, T24 and T36 (brackets recovered after 12, 24, and 36 months of treatment, respectively), rectangular stainless steel arch wires that remained in the oral cavity for 12 to 24 months were also analyzed. Dimensional stability, surface morphology and composition of brackets, resistance to sliding of the bracket/wire set and surface roughness of wires were analyzed by optical microscopy by measurement, scanning electron microscopy and energy dispersive x-ray, universal test machine and atomic force microscopy assays, respectively. Oral pH was evaluated by means of pH indicator strips by the colorimetric method. One-way analysis of variance ANOVA, followed by Tukey multiple comparisons test were used for statistical analysis (p<0.05). RESULTS: There was gradual influence of time from the 12th to 36th month for biofilm and food debris accumulation on bracket surfaces, presence of deformations on winglets and points of corrosion. Occlusal and cervical heights of brackets increased significantly after clinical use for 36 months, compared with new bracket heights (p<0.05). Carbon and Oxygen were shown to be elements that increased expressively and in direct proportion to time, and there was a progressive increase in the coefficient of friction and roughness of wires as a function of time of clinical use after 36 months. Oral pH showed significant difference only between group T36 and its control (p<0.05). CONCLUSIONS: The hypothesis was partially accepted, brackets and orthodontic wires suffered significant physical-chemical changes due to clinical use. However, the treatment time and biofilm and debris accumulation in bracket slots were shown to have more influence on the degradation process and frictional force of these devices than oral pH. / OBJETIVO: Este estudo teve como foco atestar a hipótese de que o tempo de tratamento e o pH bucal possuem influência sobre as propriedades físico-químicas de fios e bráquetes ortodônticos. MÉTODOS: Cento e vinte bráquetes metálicos foram avaliados, divididos em 4 grupos (n=30 por grupo): grupo C (Controle, como recebido do fabricante) e os grupos T12, T24 e T36 (bráquetes recuperados após 12, 24, e 36 meses de tratamento, respectivamente), fios de aço inoxidável retangulares que permaneceram na cavidade oral por 12 a 24 meses também foram analisados. Estabilidade dimensional, morfologia da superfície e composição dos bráquetes, resistência ao deslizamento do conjunto bráquete/fio e rugosidade superficial dos fios foram analisados por microscopia óptica de medição, microscopia eletrônica de varredura e por energia dispersiva de Raios X, máquina universal de ensaios e microscopia de força atômica, respectivamente. O pH bucal foi avaliado nos diferentes tempos de tratamento a partir de tiras indicadoras de pH pelo método colorimétrico. RESULTADOS: O tempo influenciou gradativamente do 12° ao 36° mês para o acúmulo de biofilme e detritos alimentares sobre a superfície dos bráquetes, presença de deformações nas aletas, além do aparecimento de pontos de corrosão. Alturas oclusal e cervical dos bráquetes aumentaram significativamente após o uso clínico de 36 meses comparado as alturas dos bráquetes novos (p<0.05). Carbono e Oxigênio demonstraram ser elementos com aumentos expressivos e diretamente proporcional ao tempo, assim como, houve um aumento progressivo do coeficiente de atrito e rugosidade dos fios em função do tempo de uso clínico com maior aumento após 36 meses. O pH bucal demonstrou diferença significativa apenas entre o grupo T36 com seu controle (p<0.05). CONCLUSÕES: A hipótese foi parcialmente aceita, bráquetes e fios ortodônticos apresentaram alterações físico-químicas significativas devido ao uso clínico. No entanto, o tempo de tratamento e o acúmulo de biofilme/detritos nos slots dos bráquetes demonstraram ser mais influentes sobre o processo de degradação e força de atrito destes dispositivos do que o pH bucal.

Page generated in 0.0315 seconds