• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 41
  • 12
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 97
  • 97
  • 97
  • 29
  • 20
  • 15
  • 15
  • 15
  • 14
  • 14
  • 13
  • 12
  • 12
  • 12
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Residuos de agrotoxicos em lodo de estacao de tratamento de agua: validacao de metodologia analitica utilizando cromatografia liquida acoplada a espectrometria de massas em TANDEM (LC-MS/MS) / Pesticides residues in water treatment plant sludge: validation of analytical methodology using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS)

MORACCI, LUIZ F.S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:55:14Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:02Z (GMT). No. of bitstreams: 0 / O quadro evolutivo da agricultura brasileira resulta em benefícios à população exigindo crescentes avanços tecnológicos no setor. Constantemente, novos agrotóxicos são introduzidos estimulando estudos científicos com a finalidade de determinar e avaliar os impactos na população e no meio ambiente. No presente trabalho, a matriz avaliada foi o lodo gerado no processo de tratamento de água para consumo humano, coletado na região do Vale do Ribeira, SP. A técnica empregada foi a cromatografia líquida de fase reversa acoplada à espectrometria de massas triploquadrupolar em tandem com ionização por electrospray. Os compostos foram extraídos previamente da matriz. O desenvolvimento da metodologia exigiu tratamento dos dados para que esses pudessem ser utilizados e transformados em informações confiáveis. Os processos envolvidos foram avaliados usando o conceito da validação de ensaios químicos. Os indicadores avaliados foram seletividade, linearidade, intervalo de trabalho, sensibilidade, exatidão, precisão, limite de detecção, limite de quantificação e robustez. Esses indicadores produziram valores quantitativos e qualitativos que foram estatisticamente evidenciados de forma objetiva. A metodologia desenvolvida e validade é simples. Como resultado, mesmo explorando a sensibilidade da técnica, os compostos estudados não foram encontrados no lodo da ETA de Registro. Isso leva a crer que esses compostos podem estar presentes em concentrações muito baixas, podem sofrer degradação durante o tratamento da água ou não são retidos completamente pela ETA. 7 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
52

Abordagem sistêmica do sistema de tratamento de água de Registro, São Paulo, com ênfase na avaliação do impacto do descarte dos resíduos na bacia hidrográfica do rio Ribeira de Iguape

REIS, EDSON L.T. dos 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:51:28Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:15Z (GMT). No. of bitstreams: 0 / A crescente preocupação dos órgãos de vigilância ambiental e sanitária sobre a segurança e a qualidade dos recursos hídricos tem orientado o desenvolvimento de diversas pesquisas voltadas para uma revisão do padrão tecnológico atual, quanto à gestão de resíduos gerados em estações de tratamento de água. Neste trabalho, foram avaliadas as principais características dos resíduos gerados em um sistema de tratamento de água de ciclo completo na cidade de Registro (SP) e sua correlação com a qualidade do meio hídrico, pelo estudo dos efeitos físico-químicos de seu descarte na qualidade da água e do sedimento da Bacia Hidrográfica do rio Ribeira de Iguape. Um programa de monitoramento da microbacia foi estabelecido, verificando-se o atendimento dos elementos analisados ás exigências de legislações federais, como a Resolução CONAMA 357/2005 e a Portaria 518. Foram constatadas alterações na qualidade da água superficial do corpo d\'água receptor em períodos de até 4 horas, após o despejo, e para uma distância de até 50 m a jusante do descarte do lodo da ETA. A análise descritiva mostrou ser predominante a concentração de alguns metais durante o descarte, como o manganês. A análise dos organismos bentônicos apresentou uma indicação de que os grupos observados não foram diretamente afetados pelo despejo do lodo da ETA. O presente trabalho não detectou indícios de que a contaminação constatada no local de despejo atingisse o rio Ribeira de Iguape, porém, a presença de alumínio em amostras de sedimento próximo ao local de descarte mostrou que o descarte sistemático do lodo pode comprometer em longo prazo a qualidade da água do corpo d\'água receptor. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
53

Desenvolvimento de tijolos com incorporação de cinzas de carvão e lodo proveniente de estação de tratamento de água / Development of bricks with incorporation of coal ash and sludge from water treatment plant

SILVA, MAURO V. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:34:21Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:10:41Z (GMT). No. of bitstreams: 0 / Os lodos provenientes de estação de tratamento de água brasileira são, frequentemente, dispostos e lançados diretamente nos corpos d\'água, causando um impacto negativo no meio ambiente. Também, cinzas de carvão são produzidas pela queima de carvão em usinas termelétricas e é o resíduo sólido industrial mais gerado no sul do Brasil: cerca de 4 milhões ton/ano. A disposição eficiente das cinzas de carvão é um problema devido ao seu volume maciço e aos riscos nocivos para o ambiente. O objetivo deste trabalho foi estudar a viabilidade da incorporação desses dois resíduos industriais em uma massa utilizada na fabricação de tijolos ecológicos. As amostras de cinzas leve do filtro ciclone da usina termelétrica localizada no Município de Figueira, Estado do Paraná, Brasil e o lodo de estação de tratamento de água localizada no município de Terra Preta, Estado de São Paulo, Brasil, foram utilizados no estudo. Tijolos de cinzas leve-lodo e cinzas leve-lodo-solo-cimento foram moldados e testados de acordo com padrões brasileiros. Os materiais foram caracterizados por análises físico-químicas, difração de raios X, análise térmica, análise morfológica, espectroscopia no infravermelho com transformada de Fourier e análise granulométrica. Os resultados indicaram que o lodo de estação de tratamento de água e as cinzas de carvão podem ser usados na manufatura de tijolos prensados solo-cimento de acordo com a Norma Brasileira NBR 10836/94. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
54

Aumento da capacidade da estação de tratamento de água nº 2 de Valinhos - SP, utilizando polímero natural como auxiliar de floculação / Upgrading capacity of water treatment plant nº 2 of Valinhos-SP, by natural polymer addition as flocculation aid

Luiz Carlos Alves de Souza 14 March 2003 (has links)
A utilização de polímero natural como auxiliar de floculação pode ser alternativa interessante para o aumento da capacidade de estações de tratamento de água para abastecimento. O polímero natural é um produto de baixo custo, de fácil preparo e aplicação. Por ser produzido em larga escala e utilizado nos mais diversos setores da indústria, o polímero natural apresenta-se como alternativa aos polímeros sintéticos que, de maneira geral, são produtos de elevado custo e produzidos com matéria prima geralmente importada. No presente trabalho procurou-se demonstrar a eficiência dos polímeros naturais de fécula de batata e de fécula de mandioca na clarificação da água, mediante a realização de ensaios de laboratório e testes de campo - realizados na estação de tratamento ETA-2 de Valinhos (SP) - para diferentes características da água bruta. A gelatinização dos polímeros foi feita à temperatura ambiente, utilizando-se hidróxido de sódio. Para os testes na ETA-2, foram aproveitadas as instalações existentes e executadas pequenas adaptações para aplicação dos polímeros naturais. Conclui-se que, apesar de alguns ajustes que devem ser feitos, principalmente nos filtros, é possível utilizar os polímeros naturais na ETA-2 com grande probabilidade de êxito, com vistas ao aumento da capacidade de tratamento. Os resultados demonstraram que, tanto o polímero de fécula de batata como o de fécula de mandioca, foram eficientes como auxiliares de floculação na clarificação da água. / Natural polymer utilization as flocculation aid may be an effective alternative for upgrading the capacity of water treatment plants with low cost, easiers to prepare and apply. As natural polymers are large scale produced and applied in many different industrial sectors, it comes as a fesiable alternative for synthetic polymers that are generally high cost and made of imported materials. On this work it was tried to show the efficiency of natural polymers such as potato and manioc starch, for clarifying water by jar-test evaluations and field tests - carried out on water treatment plant WTP-2 of Valinhos (SP - Brazil) - for different characteristics of raw water. The polymer gelatinization was obtained by sodium hydroxide application. For the tests at WTP-2 the existing facilities were utilized and only small adaptations were made to apply natural polymers. The conclusion was, in despite of needing filters adjustments which must be made on water treatment plant for polymer application, it is possible to utilize the product with high successful probability for upgrading the capacity of water treatment plant. The results showed that even potato as well as cassava starchs were efficient on plant clarified water.
55

Análise e proposta de formas de gerenciamento de estações de tratamento de águas de abastecimento completo em cidades de porte médio do Estado de São Paulo.

Marilu Pereira Serafim Parsekian 31 July 1998 (has links)
As estações de tratamento de água são indústrias nas quais a água bruta (matéria prima)deve ser transformada em água potável (produto final) através da aplicação de produtos em operações e processos. Esta indústria é uma das poucas à qual todos os seres humanos fazem uso do seu produto. Nos últimos tempos tem-se constatado aumento na demanda que, aliado a sensível piora da qualidade da água bruta, conduz a necessidade de funcionamento eficiente das estações, tanto do ponto de vista técnico quanto do econômico. Essa eficiência só será atingida através do gerenciamento adequado. Com vistas às necessidades de nosso país nesse setor, levantou-se informações sobre algumas estações de tratamento de água de abastecimento através de visitas técnicas e aplicação de questionário elaborado. Analisou-se formas de gerenciamento para estas estações de modo que o resultado possibilitasse melhoria do produto e do serviço. Cabe salientar que este trabalho não apresenta uma análise quantitativa dos custos. O desenvolvimento do trabalho permitiu algumas sugestões: de maneira geral não tem existido por parte dos sistemas gerenciadores grandes preocupações com a qualidade dos mananciais; a aquisição dos produtos químicos é realizada pelo menor preço; um número pequeno das ETAs visitas adotam critério técnico para fazer a dosagem de produtos químicos; os resíduos gerados nos decantadores e filtros são descartados nos cursos d'água próximos as ETAs; entre outras. A partir dessas conclusões pôde-se propor medidas para o melhor funcionamento destas estações.
56

Influência da recirculação de água de lavagem de filtros na qualidade da água tratada para consumo humano / Influence of recirculation of water to wash filters in treated water quality for human consumption

Campos, Marlon Caianelo Dias, 1986- 24 August 2018 (has links)
Orientador: Ricardo de Lima Isaac / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-24T14:00:51Z (GMT). No. of bitstreams: 1 Campos_MarlonCaianeloDias_M.pdf: 3410126 bytes, checksum: bb9db3577d3074777f6ae59b1de2ad29 (MD5) Previous issue date: 2014 / Resumo: A recirculação de água de lavagem de filtro em estação de tratamento de água do tipo convencional (ETA) pode representar economia significativa tanto do recurso hídrico quanto de energia, aspecto fundamental do ponto de vista da sustentabilidade. Contudo, se praticada sem critério, tal prática operacional pode representar risco à saúde do consumidor. O objetivo geral desta pesquisa foi avaliar o impacto da recirculação da água de lavagem de filtros (ALAF) na qualidade da água tratada. O trabalho desenvolveu-se na ETA-3 de Campinas-SP que capta do manancial superficial (rio Atibaia), utiliza pré-cloração e policloreto de alumínio como coagulante no processo de tratamento. Investigou-se em escala de bancada (Jar-test) o impacto da aplicação de taxas de recirculação equivalentes a 2, 4, 6, 8 e 10 % em volume de ALAF em relação ao volume total de água tratada na formação de subprodutos de desinfecção (trihalomeanos e ácidos haloacéticos). Os parâmetros carbono orgânico total (COT), carbono orgânico dissolvido (COD), UV254, turbidez, cor (aparente e verdadeira) e metais (alumínio, bário, cádmio, chumbo, cobre, cromo, manganês, zinco e níquel) foram também avaliados. Em geral, as diferentes taxas de recirculação de ALAF não provocaram inadequações quanto ao padrão de potabilidade para os parâmetros: cor, turbidez, metais (bário, cádmio, chumbo, cobre, cromo, manganês, zinco e níquel) e trihalometanos. Quanto aos ácidos haloáceticos, porém, notou-se que não se atendeu ao valor limite estabelecido na legislação e que o aumento da taxa de recirculação provocou a elevação da concentração deste subproduto da desinfecção na água tratada / Abstract: Filter backwash water recycling at conventional water treatment plants (WTP) certainly contributes to water and energy resources rational use, essential for sustainability. However, if practiced without criteria, such operational practice may pose a risk to users¿ health. The overall objective of this research was to evaluate the impact of recirculating filter backwash water on filtered water quality. The work was carried out at Campinas WTP, Sao Paulo State, Brazil. The plant treats surface raw water from Rio Atibaia (pre-chlorination, polyaluminum chloride as main coagulant). It was investigated in lab scale (jar-test) the effect of applying recirculation flowrate corresponding to 2, 4, 6, 8 and 10 % volume of backwash water ratio to total volume of treated water on the formation of disinfection byproducts (trihalomethane, THM and haloacetic acids, HAA). Metals content (aluminum , barium, cadmium, lead, copper, chromium , manganese, zinc and nickel), total organic carbon (TOC), dissolved organic carbon (DOC) , UV254 , turbidity, apparent and true color were also evaluated . In general, tested recirculation rates did not cause filtered water quality mismatches to drinking water standards for the parameters: color, turbidity, metals (barium, cadmium, lead, copper, chromium, manganese, zinc and nickel) and THM. However, for HAA it was found that recycling led to concentration values upper than the maximum contaminant level in Brazilian drinking water standards. Increasing the rate, higher was the concentration of this disinfection by-product in treated water / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
57

Caracterização microbiológica, parasitológica e físico-química da água de lavagem de filtros recirculada em ETA de ciclo completo = Microbiological, parasitological and physico-chemical characterization of filter backwash water recirculated in full cycle WTP / Microbiological, parasitological and physico-chemical characterization of filter backwash water recirculated in full cycle WTP

Canale, Ivan, 1977- 11 April 2014 (has links)
Orientador: Cassiana Maria Reganhan-Coneglian / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Tecnologia / Made available in DSpace on 2018-08-26T04:53:56Z (GMT). No. of bitstreams: 1 Canale_Ivan_M.pdf: 7288933 bytes, checksum: 93678fbce9055e79b05000fd1cab8c23 (MD5) Previous issue date: 2014 / Resumo: Estações de Tratamento de Água (ETA) de ciclo completo. Como o volume de ALF pode representar de 3 a 6% do volume de água tratada produzido na ETA, existe interesse cada vez maior no tratamento desse efluente para fins de recirculação junto com a água bruta aduzida à ETA. Entretanto, existe uma preocupação de que essa água residuária possa conter matéria orgânica, sólidos totais, metais, carbono orgânico, precursores de trihalometanos, cistos/oocistos de protozoários ou outras impurezas concentradas durante o processo de filtração. Este trabalho de pesquisa tem como objetivo caracterizar com base em parâmetros físico-químicos, microbiológicos e parasitológicos a água de lavagem de filtros gerada e recirculada na ETA Capim Fino, em Piracicaba / SP - Brasil. Foram avaliadas 12 amostras da água bruta do manancial que abastece a ETA (rio Corumbataí), ALF bruta, ALF clarificada (com o uso de polímeros auxiliares ou por simples sedimentação) e água filtrada da ETA. Para caracterização da ALF foram analisados os parâmetros físico-químicos: cloro residual, cor, turbidez, pH, alumínio solúvel, sólidos totais fixos, sólidos totais voláteis, sólidos sedimentáveis, carbono orgânico total e o potencial de formação de trihalometanos; os parâmetros microbiológicos: coliformes totais, Escherichia coli; e os protozoários patogênicos: Giardia spp. e Cryptosporidium spp. O monitoramento da ALF bruta apontou como principais características físico-químicas deste efluente elevados teores de turbidez, alumínio, carbono orgânico total, sólidos totais (fixos e voláteis), sólidos sedimentáveis e potencial de formação de THM. A clarificação da ALF com polímero aniônico possibilitou a redução na concentração dos diversos constituintes analisados. Giardia spp. foi detectada na água bruta (cinco resultados positivos e concentração de cistos variando de <LMD a 75,0 cistos/litro) e na ALF clarificada (dois resultados positivos e concentração de 50 cistos/litro). A pré-cloração realizada na ETA, bem como o uso de água tratada (clorada) para lavagem dos filtros garantiu praticamente ausência de E. coli na água de lavagem. A avaliação da água filtrada da ETA apresentou resultados em conformidade com a Portaria 2914/2011 (padrão de potabilidade) do Ministério da Saúde, com exceção da turbidez, onde foram observados quatro resultados acima do limite de 0,5 NTU estabelecido pela Portaria (1,53, 0,54 , 0,59 e 0,74 NTU), o que pode indicar um transpasse de partículas no efluente filtrado nos primeiros minutos seguintes à lavagem dos filtros. Não foram detectados E. coli ou protozoários na água filtrada. Diante do fato que a recirculação da ALF clarificada junto com a água bruta está ocorrendo numa vazão de 60 L/s, que corresponde a 4,5% da vazão de água bruta (1300 L/s) e de forma intermitente, provavelmente não deverão ocorrer efeitos indesejáveis ao processo de tratamento ou o comprometimento da qualidade da água tratada. Com intuito de precaução, é importante que seja dada toda a atenção ao tratamento (clarificação) da ALF antes da recirculação, para redução da turbidez a níveis mínimos possíveis e que a recirculação do efluente clarificado seja realizada na vazão de 4,5% ou menor / Abstract: Filter backwash water (FBWW) is the largest liquid waste generated in a conventional water treatment plant (WTP). As the volume of FBWW can represent from 3 to 6% of the volume of treated water produced in the WTP, there is an increasing interest in treatment and recycling of this effluent with raw water adducted to WTP. But FBWW would contain concentrated organic matter, total solids, metals, organic carbon, trihalomethanes (THM) precursors, cysts/oocysts of protozoa and other impurities which could be a concern. This research aims to characterize FBWW generated and recirculated in Capim Fino WTP in Piracicaba / SP - Brazil by physico-chemical, microbiological and parasitological analyses. Twelve samples of raw water from the river that supplies the WTP (Corumbataí river), raw FBWW, clarified FBWW (using auxiliary polymers or simple sedimentation) and filtered water were collected and evaluated. The physico-chemical parameters were: residual chlorine, color, turbidity, pH, soluble aluminum, total fixed and volatile solids, settleable solids, total organic carbon and THM potential formation; microbiological parameters: total coliforms and Escherichia coli; and pathogenic protozoa Giardia spp. and Cryptosporidium spp. Monitoring the raw FBWW pointed as the main physicochemical characteristics high levels of turbidity, aluminum, total organic carbon, total solids (fixed and volatile), sedimentary solids and THM potential formation. Clarification of FBWW with anionic polymer resulted in a reduction in the concentration of the various parameters. Giardia spp. was found in raw water (five positive results and cyst concentration ranging from <Minimum Detection Limit to 75 cysts/liter) and in clarified FBWW (two positive results, concentration of 50 cysts/liter). The pre-chlorination performed in the WTP and the use of treated water (chlorinated) for washing the filters virtually assured absence of E. coli in the FBWW. The filtered water were in compliance with the Brazilian drinking water standards, with the exception of turbidity. Four samples were above the maximum limit of 0.5 NTU (1.53, 0.54, 0.59 and 0.74 NTU), which may indicate a passage of particles in the first minutes after the washing of the filters. E. coli and protozoa were not detected in the filtered water. Because of the recirculation of clarified FBWW is mixed with raw water at a flow of 60 L/s, which corresponds to 4.5% of the flow of raw water (1300 L/s) and intermittently, it is probable that no undesirable effects would occur in the treatment and in the quality of the drinking water. It is important that full attention is given to treatment (clarification) of FBWW before recirculation to reduce turbidity to the minimum levels that are possible and that the recirculation of clarified effluent is conducted at a flow rate of 4.5% or less / Mestrado / Tecnologia e Inovação / Mestre em Tecnologia
58

An Arduino Based Control System for a Brackish Water Desalination Plant

Caraballo, Ginna 08 1900 (has links)
Water scarcity for agriculture is one of the most important challenges to improve food security worldwide. In this thesis we study the potential to develop a low-cost controller for a small scale brackish desalination plant that consists of proven water treatment technologies, reverse osmosis, cation exchange, and nanofiltration to treat groundwater into two final products: drinking water and irrigation water. The plant is powered by a combination of wind and solar power systems. The low-cost controller uses Arduino Mega, and Arduino DUE, which consist of ATmega2560 and Atmel SAM3X8E ARM Cortex-M3 CPU microcontrollers. These are widely used systems characterized for good performance and low cost. However, Arduino also requires drivers and interfaces to allow the control and monitoring of sensors and actuators. The thesis explains the process, as well as the hardware and software implemented.
59

Perfluorinated compounds, bishenol a and acetaminophen in selected waste water treatment plants in and around Cape Town, South Africa

Adeleye, Adeola Patience January 2016 (has links)
Thesis (MTech (Chemistry))--Cape Peninsula University of Technology, 2016. / The release of wastewater to the aquatic environment is most likely to introduce some trace levels of organic contaminants, some of which may be toxic, carcinogenic, or endocrine disruptors, as well as, persistent in the environment. Additionally, increasing contamination of surface waters by wastewater effluents has made water treatment processes more challenging and expensive. The presence of these pollutants in the receiving water body may have negative effects on aquatic species and often pose potential human health risks through the reuse of treated wastewater for drinking purposes and other household use. In countries like South Africa, Namibia, USA, Singapore and Australia, water agencies are intensifying wastewater reclamation/wastewater reuse as part of their water resource agenda: in order to meet the demands of the growing populations. Nowadays, water reuse is generally considered as a viable method of water supply management. This study focused on the identification of the occurrence, quantification of emerging contaminants and evaluation of removal efficiency in wastewater treatment processes of three classes of emerging contaminants (ECs) in wastewater: 1) six types of perfluorinated compounds (PFCs), namely; perfluorooctanoic acid (PFOA), Perfluorooctane sulphonate (PFOS), perfluoroheptanoic acid (PFHpA), perfluorononanoic acid (PFNA), perfluorodecanoic acid (PFDA), and perfluoroundecanoic acid (PFUDA); 2) bisphenol A (BPA); and 3) Acetaminophen (ACP). These contaminants were identified and quantified in four wastewater treatment plants in the Western Cape. These treatment plants include three WWTPs in Cape Town, namely: Bellville WWTP, Scottsdene WWTP and Zandvliet WWTP and one WWTP in the central Karoo (Beaufort West wastewater reclamation plant).
60

Renovering av betongkonstruktioner i vattenverk

Landin, Johan January 2019 (has links)
Omkring 1970 byggdes och renoverades många vattenverk i Sverige. Dessa beräknadesdå att ha en livslängd på mellan 50-60 år, vilket i de flesta fall nu har passerat.Det har hittills saknats enhetlig information gällande hur renovering av enbassängkonstruktion i ett vattenverk bäst går till. Detta motiverade tillkomsten av följandearbete. Syftet är att undersöka vilka renoveringsmetoder som finns samt sammanställaoch utvärdera dessa. Målet är att presentera vilka riktlinjer som bör följas vid renoveraringav betongkonstruktioner i vattenverk.Arbetet ger svar på vilka skador som är vanliga i vattenverk och vad de beror på, vilkarenoveringsmetoder som är bäst lämpade, vilka material som kan användas samt vilkakrav som ställs på slutresultatet.Litteratur som behandlar betongrenovering har tjänat som utgångsmaterial. Intervjuer harskett med betongexperter, vattenverkspersonal och entreprenörer som utför denna typ avarbete.Problem i vattenverk är främst sprickor, urlakning, mekanisk erosion, korrosionsskador,kemiskt angrepp, biologisk nedbrytning och frostskador. Dessa skador renoveraslämpligen genom att ta bort den skadade betongen och ersätter den med ny, utifrån denexponeringsklass som gäller för det aktuella objektet.Borttagning av den dåliga betongen ska mot slutet göras med försiktighet för att undvikafickor vid armering och mikrosprickor i kvarvarande betong. För att få ett bra resultatkrävs både uppruggning av ytan som ska pågjutas samt fukthärdning efteråt. Vatten är ettlivsmedel så det ställs hårda renhetskrav på arbetare och maskiner samt krav på att allaprodukter som används är livsmedelsgodkända.Den slutsats som dras är att det idag inte finns någon generell och exaktrenoveringsmetod för betongkonstruktioner i vattenverk. Många olika faktorer spelar in.Det skulle dock fylla en kunskapslucka och underlätta framtida renoveringar omvattenverken gjorde en gemensam sammanställning av sina erfarenheter och lärdomar.Likaså är det ett stort värde att utbilda sin personal. / Around 1970 many water treatment plants were built and renovated in Sweden. Thesewas calculated to have a service life of between 50-60 years, which in most cases nowhave passed.The aim is to investigate which renovation methods exist and compile and evaluate these.The goal is to present which guidelines should be followed when renovating concretestructures in water treatment plants.The work gives answers to what damage is common in water treatment plants and whatthey depend on, which renovation methods are best suited, which materials can be usedand which requirements are set on the result.Problems in water treatment plants are mainly cracks, leaching, mechanical erosion,corrosion damage, chemical attack, biodegradation and frost damage. These damages arepreferably renovated by removing the damaged concrete and replacing it with new, basedon the exposure class that applies to the object in question.The conclusion is that today there is no general and exact renovation method for concretestructures in water treatment plants. Many different factors are involved.However, it would fill a gap of knowledge and facilitate future renovations if the watertreatment plants made a joint compilation of their experiences and lessons learned. It isalso a great value to educate the personnel.

Page generated in 0.0782 seconds