• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Absorptionskylmaskiner ombord : En undersökning om absorptionsprocessens potential ombord fartyg

Ahlin, Kristofer January 2014 (has links)
Målet med denna undersökning är att teoretiskt undersöka den vatten/litiumbromidbaserade absorptionsprocessens potential ombord fartyg då processen enbart drivs av huvudmaskinens högtemperaturkylvatten. Undersökningen genomförs teoretiskt mot tre olika fartyg samt Sjöfartshögskolan i Kalmars maskinrumssimulator. För vardera fartyg undersöks driftenergikällan och kylbehovet ombord. Med det som underlag dras en slutsats om den vatten/ litiumbromidbaserade absorptionsprocessens potential ombord fartyget. Fartygens resultat ligger till grund för slutsatsen. Undersökningen visade att det finns potential för tekniken ombord undersökta fartyg.
2

Fjärrvärmedriven absorptionskyla i Hedemora och Säter / District Heating Driven Absorption Cooling in Hedemora and Säter

Boman, Johan January 2016 (has links)
Hedemora Energi produces and distributes district heating in Hedemora and Säter. It is during the summer in these cities, as in the rest of the country, a low heating demand. By offering its customers district heating driven absorption cooling, this could be a way to satisfy more requests while being able to sell more heat and better use the available capacity.  In this thesis the cooling potential in Hedemora and Säter is calculated. Furthermore, the impact of integrated absorption chillers on district heating production, as well as absorption cooling profitability for Hedemora Energi is investigated. Simulations and calculations show that the system need to be adjusted for absorption cooling by increasing the supply temperatures during the hours that they are below the requirements of the absorption chillers. In addition, the adjustments cause raised return temperatures and altered flows in the network. This results in increased fuel costs and heat losses, reduced flow revenues and reduced heat supplies from flue gas condensers. Despite this, the economic results are positive for all cases. For example, over 44 thousand SEK in annual profit after integration of absorption chillers, producing 422 MWh of cooling in Skönvik, Säter.
3

Kryogen uppgradering av biogas med kyla från värmedriven absorptionskylmaskin

Hermansson, Henrik January 2009 (has links)
<p>Detta är ett examensarbete som genomförts hos Göteborg Energi AB och syftar till att utreda omkryogen uppgradering av biogas med fördel kan ske genom att producera nödvändig kyla medvärmedriven absorptionskylmaskin. Göteborg Energi är en av tre parter som tillsammans ska bygga enbiogasanläggning i Lidköping som ska vara i drift 2010. Anläggningen ska producera 30 GWhflytande biogas per år.</p><p>Arbetet utreder om det är fördelaktigt ur ekonomiskt, energimässigt och miljömässigt perspektiv attuppgradera biogas med kryogen teknik med värmeproducerad kyla. En jämförelse görs först medkryogen teknik där kylan är producerad med el och sen med andra uppgraderingstekniker. Som stödhar två olika processimuleringsprogram används, Hysys och DESIGN II.</p><p>Resultatet visar att energianvändningen ökar då värmedriven kyla används i jämförelse med kylaproducerad med el. 0,47 kW/Nm3 rågas för kryo med absorptionskyla och 0,29 kW/Nm3 rågas medel. Om det finns avsättning för spillvärmen kan energianvändningen i uppgraderingen minska till 0,29kW/Nm3 rågas och 0,15 kW/Nm3 rågas för systemet med värmedriven respektive eldriven kyla. Ijämförelse med andra uppgraderingstekniker ligger 0,47 kW/Nm3 bland de teknikerna med högstenergianvändning medans 0,29 kW/Nm3 placerar sig bland de teknikerna med lägstenergianvändning.</p><p>Resultat visar att klimatpåverkan från uppgraderingen, som kommer av metanslip och elanvändningen,minskar marginellt om kylan produceras med värme istället för el. Resultatet varierar mycket beroendepå hur koldioxidutsläppen från marginalelen beräknas. I jämförelse med andra uppgraderingsteknikerligger kryo lägre än de flesta andra. Undantaget är COOAB-tekniken som är överlägset bäst tack varalågt metanslip och liten elanvändning.</p><p>Ekonomisk jämförelse med andra uppgraderingstekniker visar att kostnaden för energianvändningenligger i samma nivå som övriga uppgraderingstekniker i jämförelsen, ca 0,03 kr/kWh uppgraderad gas.Om det finns avsättning för spillvärmen sjunker kostnaden till 0,024 och 0,02 kr/kWh uppgraderad gasför kryoteknik med kyla ifrån värme respektive el.</p><p>Min slutsats är att utnyttjande av spillvärmen är av stor vikt för att få god ekonomi och lågenergianvändning med kryogen uppgradering. En marginellt förbättrad miljöprestanda kan erhållas omnödvändig kyla produceras med värme istället för el då kryogen uppgradering används. Annars är detalltid mer fördelaktigt att använda el för att producera nödvändig kyla.</p> / <p>This is a master thesis that has been carried out at Göteborg Energi AB. It refers to investigate ifcryogenic upgrading of biogas with advantage can be done by producing necessary cold with a heatdriven absorption cooling machine. Göteborg Energi is one of three actors that together will build abiogas plant in Lidköping that will be up and running in 2010. The plant will produce 30 GWhliquefied biogas annually.</p><p>This thesis investigastes whether it is advantageous, to upgrade biogas with heat driven cooling, in aperspective of economy, energy use and environment. It compares cryogenic upgrading with coldproduced by electricity, but also by other techniques. Two different process simulation softwares havebeen used as support to this thesis; Hysys and DESIGN II.</p><p>The result shows that energy usage increases when the necessary cold is produced with heat instead ofelectricity; 0,47 kW/Nm3 rawgas for cryo upgrade with absorptions cooling and 0,29 kW/Nm3 rawgaswith cold produced by electricity. If it’s possible to use the waste heat to warm the digester, the energyconsumption for the upgrading can be reduced to 0,29 kW/Nm3 for the system with heat-driven cold,and 0,15 kW/Nm3 rawgas for cold produced by electricity. In comparison with other techniques forupgrading, 0,47 kW/Nm3 rawgas is a high value while 0,29 kW/Nm3 rawgas is among the lowestvalues for energy use.</p><p>The impact on the climate emerges from the use of electricity and when methane slips out from theupgrading plant. The result shows that the impact on the climate is slightly decreased for cryogenicupgrading when the cold is produced with a heat driven absorption machine instead of electricity. Theresult varies a lot due to how one calculate the emission of carbon dioxide from the electricity on themargin. In comparison with other upgrading techniques, the climate impact from cryogenic upgradingis less, other than the COOAB-technique that is superior because of its low methane slip and lowdemand of electricity.</p><p>An economical comparison shows that the cost for energy usage is about the same for cryogenic as forother techniques; approximately 0,03 SEK/kWh upgraded gas. If one can utilize the waste heat, thecost would be decreased to 0,024 and 0,02 SEK/kWh upgraded gas for the system with cryogenicupgrading with cooling from absorption machine respectively cooling produced with electricity.</p><p>My conclusion is that the utilization of the waste heat is essential if one wishes to get good economyand low energy use for the upgrading of biogas with cryogenic methods. A slightly increasedenvironmental improvement can be received if one change the cold production from electricity to heat,otherwise it is always more advantageous to use electricity for cryogenic methods.</p>
4

Kryogen uppgradering av biogas med kyla från värmedriven absorptionskylmaskin

Hermansson, Henrik January 2009 (has links)
Detta är ett examensarbete som genomförts hos Göteborg Energi AB och syftar till att utreda omkryogen uppgradering av biogas med fördel kan ske genom att producera nödvändig kyla medvärmedriven absorptionskylmaskin. Göteborg Energi är en av tre parter som tillsammans ska bygga enbiogasanläggning i Lidköping som ska vara i drift 2010. Anläggningen ska producera 30 GWhflytande biogas per år. Arbetet utreder om det är fördelaktigt ur ekonomiskt, energimässigt och miljömässigt perspektiv attuppgradera biogas med kryogen teknik med värmeproducerad kyla. En jämförelse görs först medkryogen teknik där kylan är producerad med el och sen med andra uppgraderingstekniker. Som stödhar två olika processimuleringsprogram används, Hysys och DESIGN II. Resultatet visar att energianvändningen ökar då värmedriven kyla används i jämförelse med kylaproducerad med el. 0,47 kW/Nm3 rågas för kryo med absorptionskyla och 0,29 kW/Nm3 rågas medel. Om det finns avsättning för spillvärmen kan energianvändningen i uppgraderingen minska till 0,29kW/Nm3 rågas och 0,15 kW/Nm3 rågas för systemet med värmedriven respektive eldriven kyla. Ijämförelse med andra uppgraderingstekniker ligger 0,47 kW/Nm3 bland de teknikerna med högstenergianvändning medans 0,29 kW/Nm3 placerar sig bland de teknikerna med lägstenergianvändning. Resultat visar att klimatpåverkan från uppgraderingen, som kommer av metanslip och elanvändningen,minskar marginellt om kylan produceras med värme istället för el. Resultatet varierar mycket beroendepå hur koldioxidutsläppen från marginalelen beräknas. I jämförelse med andra uppgraderingsteknikerligger kryo lägre än de flesta andra. Undantaget är COOAB-tekniken som är överlägset bäst tack varalågt metanslip och liten elanvändning. Ekonomisk jämförelse med andra uppgraderingstekniker visar att kostnaden för energianvändningenligger i samma nivå som övriga uppgraderingstekniker i jämförelsen, ca 0,03 kr/kWh uppgraderad gas.Om det finns avsättning för spillvärmen sjunker kostnaden till 0,024 och 0,02 kr/kWh uppgraderad gasför kryoteknik med kyla ifrån värme respektive el. Min slutsats är att utnyttjande av spillvärmen är av stor vikt för att få god ekonomi och lågenergianvändning med kryogen uppgradering. En marginellt förbättrad miljöprestanda kan erhållas omnödvändig kyla produceras med värme istället för el då kryogen uppgradering används. Annars är detalltid mer fördelaktigt att använda el för att producera nödvändig kyla. / This is a master thesis that has been carried out at Göteborg Energi AB. It refers to investigate ifcryogenic upgrading of biogas with advantage can be done by producing necessary cold with a heatdriven absorption cooling machine. Göteborg Energi is one of three actors that together will build abiogas plant in Lidköping that will be up and running in 2010. The plant will produce 30 GWhliquefied biogas annually. This thesis investigastes whether it is advantageous, to upgrade biogas with heat driven cooling, in aperspective of economy, energy use and environment. It compares cryogenic upgrading with coldproduced by electricity, but also by other techniques. Two different process simulation softwares havebeen used as support to this thesis; Hysys and DESIGN II. The result shows that energy usage increases when the necessary cold is produced with heat instead ofelectricity; 0,47 kW/Nm3 rawgas for cryo upgrade with absorptions cooling and 0,29 kW/Nm3 rawgaswith cold produced by electricity. If it’s possible to use the waste heat to warm the digester, the energyconsumption for the upgrading can be reduced to 0,29 kW/Nm3 for the system with heat-driven cold,and 0,15 kW/Nm3 rawgas for cold produced by electricity. In comparison with other techniques forupgrading, 0,47 kW/Nm3 rawgas is a high value while 0,29 kW/Nm3 rawgas is among the lowestvalues for energy use. The impact on the climate emerges from the use of electricity and when methane slips out from theupgrading plant. The result shows that the impact on the climate is slightly decreased for cryogenicupgrading when the cold is produced with a heat driven absorption machine instead of electricity. Theresult varies a lot due to how one calculate the emission of carbon dioxide from the electricity on themargin. In comparison with other upgrading techniques, the climate impact from cryogenic upgradingis less, other than the COOAB-technique that is superior because of its low methane slip and lowdemand of electricity. An economical comparison shows that the cost for energy usage is about the same for cryogenic as forother techniques; approximately 0,03 SEK/kWh upgraded gas. If one can utilize the waste heat, thecost would be decreased to 0,024 and 0,02 SEK/kWh upgraded gas for the system with cryogenicupgrading with cooling from absorption machine respectively cooling produced with electricity. My conclusion is that the utilization of the waste heat is essential if one wishes to get good economyand low energy use for the upgrading of biogas with cryogenic methods. A slightly increasedenvironmental improvement can be received if one change the cold production from electricity to heat,otherwise it is always more advantageous to use electricity for cryogenic methods.

Page generated in 0.102 seconds