• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 56
  • 3
  • 2
  • Tagged with
  • 61
  • 27
  • 22
  • 16
  • 16
  • 14
  • 12
  • 11
  • 10
  • 10
  • 9
  • 8
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Estudo de viabilidade técnica econômica para implementação de uma unidade móvel para tratamento de efluentes industriais com feixe de elétrons / Study of technical and economical feasibility for implementation of a movable unit for treatment of industrial effluents with electron beam

Rela, Carolina Sciamarelli 21 November 2006 (has links)
O tratamento de efluentes industriais é uma prática que vem se disseminando em ritmo acelerado, porque além de contribuir para reforçar a imagem pública, através do combate à poluição, ela traz vantagens econômicas para as empresas que podem reutilizar a água tratada do efluente em seus próprios processos. A técnica de tratamento estudada no presente trabalho é a que utiliza a oxidação/redução química destacando-se a utilização da radiação ionizante por meio de feixes de elétrons. Esta técnica utiliza um processo oxidativo avançado, gerando radicais altamente reativos que provocam a oxidação, redução, dissociação e degradação em compostos orgânicos e exercendo efeito letal nos microorganismos, protozoários e parasitas em geral. Neste trabalho desenvolveu-se um projeto conceituai e básico de uma unidade móvel de tratamento de efluentes utilizando radiação ionizante, fazendo com que a unidade se desloque até o ponto de tratamento, facilitando assim a logística. Em seguida, elaborou-se um estudo de viabilidade técnica e econômica permitindo dados consistentes sobre a capacidade e custo de processamento de efluentes e valores consolidados dos investimentos necessários para serem apresentados a órgãos financiadores para a construção de uma unidade móvel. Os resultados dos estudos demonstram que é viável tecnicamente a construção de uma unidade móvel, pois atende a legislação pertinente do Brasil, nos aspectos de Radioproteção e limite de transporte de carga. O custo unitário do processamento mostrou-se superior ao de uma unidade fixa em razão da diminuição da eficiência da interação da radiação incidente no efluente processado, devido à redução de energia do acelerador de elétrons e da disponibilidade de operação da unidade. / The treatment of industrial effluents is a practice that is disseminating in accelerated rhythm, of contributing to reinforce the public image, through the combat of the pollution, it brings economical advantages allowing the companies the reuse of the treated water in their own processes. The liquid effluent treatment technique studied in the present work is the one that uses the chemical oxidation/reduction standing out the use of the electron beam (e.b.) radiation. This technique uses an advanced oxidation process, generating radicals highly reagents that provoke the oxidation, reduction, dissociation and degradation in composed organic and exercising lethal effect in general in the microorganisms and parasites. In this work a conceptual and basic project of a movable unit of effluents treatment using electron beam radiation process was developed, in order that the unit moves until the treatment point, where the effluent is produced, facilitating the logistics. A technical and economical feasibility study was also elaborated allowing data on the capacity and cost of effluents processing to consolidate the values of the necessary investments to be presented to foundations organs for the construction of a movable unit. The results of the studies demonstrated that it is technically viable attending the pertinent legislation of Brazil, in the aspects of Radiation Protection and transport limit capacity. The unitary cost of the e.b. radiation processing in the movable unit was shown more expensive than in the fixed unit, the reason is the decrease of the efficiency of the interaction of the incident electrons in the effluent, due to the reduction of electron energy operation time of the unit.
52

Desenvolvimento do sistema de potência elétrica em uma unidade móvel de irradiação por feixe de elétrons para tratamento de águas residuárias e efluentes industriais / Developing an electrical power system of a mobile electron beam accelerator to treatment of industrial wastewaters and effluents

Gaspar, Renato Rache 27 September 2018 (has links)
O tratamento de águas residuárias e efluentes industriais por irradiação com feixe de elétrons é uma técnica promissora, porém pouco difundida em território Brasileiro. O projeto e a construção de uma unidade móvel contendo um acelerador industrial de elétrons de 700 keV e 20 kW, pelo Instituto de Pesquisas Energéticas e Nucleares (IPEN), é inovador para demonstrar os efeitos e resultados positivos dessa tecnologia. O propósito é deslocar a unidade móvel às diversas empresas com interesse em tratamento dos resíduos líquidos, conectar-se ao sistema elétrico da mesma e iniciar o processo de tratamento por ionização, por meio da irradiação com feixe de elétrons. A conexão da unidade móvel ao sistema elétrico local pode representar um desafio, pela grande diversidade de tensões e distâncias envolvidas, e também pelas grandes injeções de conteúdo harmônico gerado pelo acelerador de elétron que podem afetar as cargas do sistema industrial, comumente sensíveis. Neste trabalho realizou-se uma análise do sistema de potência da unidade móvel, quanto à capacidade de interrupção, seletividade da proteção e níveis de curto-circuito adequados de forma a assegurar uma maior confiabilidade na operação. Ao final, projetou-se e construiu-se o painel elétrico de controle da unidade móvel de irradiação. Além disso, na obtenção de parâmetros operacionais à unidade móvel, realizaram-se simulações e medições no acelerador industrial de elétrons de 1,5 MeV e 37,5 kW, instalado no Laboratório de Fontes Intensas de Radiação, do Centro de Tecnologia das Radiações, as quais demonstraram a necessidade da inserção de um filtro para redução dos índices de distorção nos harmônicos dessa instalação radiativa fixa no IPEN. / The treatment of wastewater and industrial effluents by electron beam irradiation is a promising technique, however, not very widespread in Brazilian territory. The design and a construction of a mobile unit containing an electron beam accelerator of 700 KeV and 20kW, by the Nuclear and Energy Research Institute (IPEN) is innovative to demonstrate the effects and positive results of this technology. The aim is to move the mobile unit to several companies with interest in liquid waste treatment, and connect to the industry electrical system and start the ionization treatment process through electron beam. The mobile unit\'s connection to the local electrical system can be a challenge in behalf of the great diversity of voltages and distances involved, as well as the large injections of harmonic content generated by the electron beam accelerator that can affect sensitive loads in the industrial system. In this work, an analysis was made of the power system of the mobile unit, regarding interruption capacity, selectivity protection and adequate short circuit levels in order to assure a greater reliability in the operation. At the end, the control panel of the mobile unit, simulations and measurements were carried out at the 1.5 MeV and 37.5 kW electron beam accelerator, installed at the Intensive Radiation Technology Center, which demonstrated the necessity of applying of a filter to reduce the measured harmonic distortion.
53

Estudo de viabilidade técnica econômica para implementação de uma unidade móvel para tratamento de efluentes industriais com feixe de elétrons / Study of technical and economical feasibility for implementation of a movable unit for treatment of industrial effluents with electron beam

Carolina Sciamarelli Rela 21 November 2006 (has links)
O tratamento de efluentes industriais é uma prática que vem se disseminando em ritmo acelerado, porque além de contribuir para reforçar a imagem pública, através do combate à poluição, ela traz vantagens econômicas para as empresas que podem reutilizar a água tratada do efluente em seus próprios processos. A técnica de tratamento estudada no presente trabalho é a que utiliza a oxidação/redução química destacando-se a utilização da radiação ionizante por meio de feixes de elétrons. Esta técnica utiliza um processo oxidativo avançado, gerando radicais altamente reativos que provocam a oxidação, redução, dissociação e degradação em compostos orgânicos e exercendo efeito letal nos microorganismos, protozoários e parasitas em geral. Neste trabalho desenvolveu-se um projeto conceituai e básico de uma unidade móvel de tratamento de efluentes utilizando radiação ionizante, fazendo com que a unidade se desloque até o ponto de tratamento, facilitando assim a logística. Em seguida, elaborou-se um estudo de viabilidade técnica e econômica permitindo dados consistentes sobre a capacidade e custo de processamento de efluentes e valores consolidados dos investimentos necessários para serem apresentados a órgãos financiadores para a construção de uma unidade móvel. Os resultados dos estudos demonstram que é viável tecnicamente a construção de uma unidade móvel, pois atende a legislação pertinente do Brasil, nos aspectos de Radioproteção e limite de transporte de carga. O custo unitário do processamento mostrou-se superior ao de uma unidade fixa em razão da diminuição da eficiência da interação da radiação incidente no efluente processado, devido à redução de energia do acelerador de elétrons e da disponibilidade de operação da unidade. / The treatment of industrial effluents is a practice that is disseminating in accelerated rhythm, of contributing to reinforce the public image, through the combat of the pollution, it brings economical advantages allowing the companies the reuse of the treated water in their own processes. The liquid effluent treatment technique studied in the present work is the one that uses the chemical oxidation/reduction standing out the use of the electron beam (e.b.) radiation. This technique uses an advanced oxidation process, generating radicals highly reagents that provoke the oxidation, reduction, dissociation and degradation in composed organic and exercising lethal effect in general in the microorganisms and parasites. In this work a conceptual and basic project of a movable unit of effluents treatment using electron beam radiation process was developed, in order that the unit moves until the treatment point, where the effluent is produced, facilitating the logistics. A technical and economical feasibility study was also elaborated allowing data on the capacity and cost of effluents processing to consolidate the values of the necessary investments to be presented to foundations organs for the construction of a movable unit. The results of the studies demonstrated that it is technically viable attending the pertinent legislation of Brazil, in the aspects of Radiation Protection and transport limit capacity. The unitary cost of the e.b. radiation processing in the movable unit was shown more expensive than in the fixed unit, the reason is the decrease of the efficiency of the interaction of the incident electrons in the effluent, due to the reduction of electron energy operation time of the unit.
54

Estudo do espalhamento e transferência elástica para o sistema 7Be+9Be / Elastic scattering and elastic transfer study of 7Be+9Be system

Uiran Umbelino da Silva 03 November 2016 (has links)
Foram realizadas medidas de espalhamento para o sistema 7Be + 9Be em ECM = 13 MeV (Elab = 23,1 MeV). A experiência foi realizada utilizando o acelerador Pelletron do Instituto de Física da Universidade de São Paulo em conjunto com o sistema RIBRAS (Radioactive Ion Beams in Brasil). As seções de choque 9Be(7Be,7Be)9Be e de transferência elástica 9Be(7Be,9Be)7Be foram obtidas e utilizadas na construção da distribuição angular completa, na região angular entre 15° até 160°. Cálculos com modelo óptico foram realizados utilizando diversos potenciais encontrados na literatura. Devido à energia do primeiro estado excitado do 7Be (Ex = 0,429 MeV) ser menor que a resolução energética do experimento, a seção de choque elástica não pode ser separada experimentalmente da inelástica, porém, através de cálculos de canais acoplados foi comprovado que o espalhamento inelástico não tem influência considerável na distribuição angular elástica. Por fim, através de cálculos de DWBA para a transferência elástica, foram obtidos fatores espectroscópicos de dois nêutrons no 9Be . Os resultados indicam que os potenciais de espalhamento e do estado ligado têm grande influência no canal de transferência elástica. / 7Be + 9Be scattering measurements were performed at ECM = 13 MeV (Elab = 23.1 MeV). The experiment was carried out in the 8UD Pelletron accelerator of the Institute of Physics of the University of São Paulo with the RIBRAS (Radioactive Ion Beams in Brasil) system. The elastic 9Be(7Be,7Be)9Be and elastic transfer 9Be(7Be,9Be)7Be cross sections were obtained and used to construct the complete angular distribution, in the angular range from 15°$ to 160°. Optical model calculations were performed using several optical potentials from the literature. Due to the first low lying excited state of 7Be (Ex = 0.429 MeV) the elastic cross section cannot be experimentally separated of the inelastic part. However, coupled channel calculations show that the contribution of the inelastic scattering has no major influence on the elastic angular distribution. Finally, the DWBA calculations for elastic transfer provide the two neutrons spectroscopic factors in 9Be. The results indicate that the transfer channel is sensitive to the bound state and optical potentials used in the analysis.
55

[en] METROLOGICAL EVALUATION OF THE RADIATION FIELD SIZE BY LINEAR ACCELERATORS / [pt] AVALIAÇÃO METROLÓGICA DO TAMANHO DE CAMPO IRRADIADO POR ACELERADORES LINEARES

NILMARA ALMEIDA GUIMARÃES 30 August 2018 (has links)
[pt] O objetivo desta dissertação é o estudo de procedimentos para avaliação da confiabilidade metrológica do tamanho de campo irradiado (TCI) por aceleradores lineares. No contexto das recentes alterações no panorama regulamentar dos serviços de radioterapia, com a implementação da RDC número 20, em 2006, pela Agência Nacional de Vigilância Sanitária (ANVISA), foi estabelecida a compulsoriedade do uso do densitômetro óptico na verificação do TCI, como parte do controle da qualidade. Questões associadas à implementação prática dos recentes requisitos para medição do tamanho de campo irradiado e as recentes indicações do potencial uso de filmes radiocrômicos para o controle da qualidade em radioterapia motivaram a realização do presente trabalho. Foram empregados três diferentes procedimentos para avaliação do tamanho de campo irradiado por aceleradores lineares utilizados em treze serviços de radioterapia localizados no Estado do Rio de Janeiro, utilizando filmes radiocrômicos EBT QD mais, RTQA, densitômetro óptico DensiX tipo T52001 ou scanner de transmissão Microtek. Os resultados destacam a contribuição das fontes de incerteza de medição para cada procedimento realizado e indicam a necessidade de considerá-la na avaliação da conformidade utilizando o densitômetro óptico (DO). Devido às propriedades do filme radiocrômico RTQA, o mesmo não pode ser utilizado no procedimento de medição com DO. Em conclusão, o uso do procedimento de medição utilizando scanner mostrou-se mais adequado para avaliação das dimensões de campos de radiação não-homogêneos. / [en] The objective of the present work is to study different procedures for metrological evaluation of the size of the radiation field emitted by linear accelerators. In the context of the recent requirements determined by the publication of the RDC number 20, in 2006, by National Agency for Sanitary Vigilance (Anvisa), the compulsory use of the optical densitometer for the measurements of the field size during quality control tests was introduced. Practical implementation issues associated with these requirements and the recent studies indicating the potential use of radiochromic films for measurements of the field size motivated the present work. Three different procedures were employed in order to evaluate the radiation field size emitted by linear accelerators used in thirteen radiotherapy services located in Rio de Janeiro, using radiochromic films EBT QD plus and RTQA, optical densitometer DensiX type T52001 or scanner Microtek. The results indicate the contribution of the measurement uncertainty associated to each procedure performed, highlighting the importance of its consideration during tests for conformity assessment with the recently required optical densitometer. Nevertheless, the RTQA radiochromic film properties precluded its use in the procedure using optical densitometer. In conclusion, among the evaluated procedures for radiation field evaluation, the use of the scanner was the most appropriate, especially if dimensional non-homogeneities are present.
56

Proposta de um novo calorímetro eletromagnético para o experimento ALICE - LHC / Proposal of a New Eletromagnetic Calorimeter for the ALICE-LHC experiment

Camila de Conti 07 November 2014 (has links)
No presente trabalho é explorada a performance do FoCal, um calorímetro eletromagnético frontal, com alta resolução espacial, proposto como um upgrade para o experimento ALICE, no LHC. O principal objetivo deste detector é fazer a medida de fótons diretos na região de pseudo-rapidez 2.5 < < 4.5. Essa região frontal é dominada por fótons provenientes do decaimento de hadrons, principalmente do píon neutro , e portanto uma eficiente medida de fótons diretos está diretamente associada à eficiência em se identificar fótons provenientes do decaimento do píon neutro. Para distinguir fótons diretos de fótons de decaimento do píon neutro, são explorados três diferentes métodos de análise, a saber, massa invariante, análise da forma do chuveiro e isolamento, sendo cada um deles adequado a uma diferente faixa de energia do píon neutro. O método da massa invariante permitiu identificar fótons de píon neutro com uma eficiência de 95% num ambiente de partículas únicas, para píon neutro com energia entre 0 e 300 GeV. Num ambiente pp, esse método mostra uma eficiência de 85%. A análise da forma do chuveiro foi capaz de identificar, com um dado corte no parâmetro de forma Width1, fótons diretos com uma eficiência acima de 90% e de rejeitar fótons de píon neutro com uma eficiência que varia de 65% a 95%, no intervalo de energia de 300 GeV a 500 GeV, num ambiente de partículas únicas. Essas eficiências podem ser melhoradas se for aplicado um corte dependente da energia e a rejeição de píon neutro pode também ser melhorada se os eventos mais assimétricos puderem ser melhor reconstruídos pelo detector no futuro. No método de isolamento, aplicado ao ambiente pp e PbPb, é explorado o melhor valor de raio de isolamento Riso a ser usado em cada ambiente. Por este método podem ser atingidas altas eficiências em detectar fótons diretos, mas o método se mostra limitado pelo grande fundo de fótons de decaimento, e a pureza dos cortes testados não atinge valores maiores que cerca de 10%. E mostrado que o uso de um trigger em 40 GeV pode melhorar a pureza dos cortes de 0.01 % para cerca de 10%. Foi feita a otimização de alguns parâmetros de análise, permitindo melhor desempenho desses métodos de análise explorados / In the present work is explored the performance of the FoCal, a forward electromagnetic calorimeter, with high granularity, proposed as an upgrade for the ALICE experiment, in LHC. The main goal of the detector is to be able to identify direct photons in the pseudo-rapidity region 2.5 < < 4.5. This forward region is dominated by decay photons, mainly photons from neutron pion decay, so an efficient mesurement of direct photons is directly associated to the efficiency in identify photons from neutron pion decay. To separate direct photons from neutron piondecay photons, it is explored three different analysis methods, the invariant mass, shower shape and isolation, each one useful in a different energy range of the neutron pion. The invariant mass method allowed to identify photons from neutron pion with an efficiency around 95% in a single particle environment, for neutron pion with energy between 0 and 300 GeV. In a pp environment, this method showed an efficiency of 85%. The shower shape method was able to identify, by a given cut in the shower shape parameter Width1, direct photons with an efficiency of 90% and to reject 65% to 95% of the photons from neutron pion in the energy range of 300 GeV to 500 GeV, in a single particle environment. This efficiencies can be improved if there is aplied a cut that depends on the energy and the neutron pion rejectioncan also be improved if the more assimetric decays can be better reconstructed by the detector in the future. The isolation method is aplied to a pp and PbPb environments, and it is explored the best value of isolation radius Riso to be used in each environment. By this method, it can be reached high efficiencies in detecting direct photons, but the method is limited by the high background of decay photons, and the purity of the cuts is not better than about 10%. It is showed that a trigger in 40 GeV can improve the purity from 0.01% to about 10%. It was made an optimization of some of the used analysis parameters, leading to an improvement of the explored analysis methods.
57

The effect of the financial accelerator over Brazilian firms: an investment analysis with evidence from 1Q2005 to 3Q2017

Silva, Nathalie dos Santos 24 July 2018 (has links)
Submitted by Nathalie dos Santos Silva (nathass@gmail.com) on 2018-09-26T14:32:48Z No. of bitstreams: 1 dissertação final c ficha.pdf: 2465918 bytes, checksum: f48edd64a1f13d747b89668b7fb3fab5 (MD5) / Approved for entry into archive by Joana Martorini (joana.martorini@fgv.br) on 2018-09-26T14:57:24Z (GMT) No. of bitstreams: 1 dissertação final c ficha.pdf: 2465918 bytes, checksum: f48edd64a1f13d747b89668b7fb3fab5 (MD5) / Approved for entry into archive by Suzane Guimarães (suzane.guimaraes@fgv.br) on 2018-09-26T17:04:37Z (GMT) No. of bitstreams: 1 dissertação final c ficha.pdf: 2465918 bytes, checksum: f48edd64a1f13d747b89668b7fb3fab5 (MD5) / Made available in DSpace on 2018-09-26T17:04:37Z (GMT). No. of bitstreams: 1 dissertação final c ficha.pdf: 2465918 bytes, checksum: f48edd64a1f13d747b89668b7fb3fab5 (MD5) Previous issue date: 2018-07-24 / This dissertation examines the impacts of monetary shocks on investment decisions of firms located in Brazil to test the presence of the financial accelerator. Because of this, after a brief review of the literature, limiting the scope of transmission via the balance sheet channel, a panel consisting of Brazilian firms from 2005 to 2017 were tested. Regression control variables include control of the effect of the BNDES on the financial leverage of firms. After tests performed under reasonable levels of significance, the resources generated internally by the firm's operations were the only variable that impacted the investments. The literature that discusses the impact of BNDES on the Brazilian capital market is also revisited in order to corroborate the results obtained in the tests. / O presente trabalho examina os impactos de choques monetários sobre decisões de investimentos de firmas localizadas no Brasil para testar se existe a presença do acelerador financeiro. Para isto, após uma breve revisão da literatura, limitando o escopo de transmissão via canal do balanço, um painel contendo firmas brasileiras de 2005 a 2017 foi testado. Dentre as variáveis de controle da regressão, inclui-se o controle do efeito do BNDES sobre a alavancagem financeira das firmas. Após testes realizados sob níveis de significância razoáveis, os recursos gerados internamente pelas operações das firmas é a única variável que impacta os investimentos. A literatura que discute o impacto do BNDES no mercado de capitais brasileiro também é revisitada de modo a corroborar os resultados obtidos nos testes.
58

Avaliação de materiais usando a radiografia computadorizada (CR) empregando um acelerador linear e cobalto - 60 como fontes de altas energias / Evaluation of materials using computed radiography (CR) employing a linear accelerator and cobalt - 60 as source of high energy

Heleno Ribeiro Simões 15 December 2012 (has links)
Nas construções de caldeiras de força, vasos de pressão e outros tipos de equipamentos para os diversos segmentos industriais têm exigido da engenharia de materiais um desenvolvimento tecnológico para melhores processos na obtenção de materiais fundidos, forjados, laminados, e outros. Desenvolver recursos tecnológicos que minimizem a presença de imperfeições que possam comprometer a integridade estrutural dos equipamentos que operam com pressão tem sido uma busca constante tanto nas usinas como nas indústrias de bens de capital nas fases das construções. Uma construção implica em seleção de materiais, projeto, fabricação, exames, inspeção, testes, certificação e dispositivos de alívio que atendam aos requisitos dos códigos e normas. Estes requisitos estão cada vez maiores e estabelecem limites para a existência destas imperfeições vão de encontro à necessidade de lançar mão de métodos de ensaios não destrutivos que permitam sempre a melhor probabilidade de detecção. Os processos de controle da qualidade têm buscado por meio das novas tecnologias aumentarem a sua sensibilidade, visando à detecção de descontinuidades que hoje são detectadas pelos métodos convencionais. Em termos de ensaios não destrutivos, as exigências para o ensaio radiográfico convencional estão no limite da sensibilidade dos filmes radiográficos industriais disponíveis, além do compromisso de buscar um tempo de exposição menor ser sempre um fator importante a ser considerado na qualidade, segurança e produtividade tanto na fábrica como no campo. O objetivo deste trabalho foi estudar e avaliar a técnica de radiografia computadorizada (RC) em relação à radiografia convencional para inspeção dos materiais, utilizando os parâmetros de avaliação, tais como, relação sinal ruído, resolução espacial, ferramentas para detectabilidade, sensibilidade ao contraste e tons de cinza, que são aplicáveis nas avaliações de imagens digitais. Para a avaliação da técnica de radiografia industrial digital foi utilizado um corpo-de-prova fabricada pelo processo de fundição com espessura de 75 a 150 mm, com defeitos típicos do processo. O corpo-de-prova foi radiografado com a técnica convencional e digital. Na técnica convencional foram utilizados os filmes radiográficos industriais tipos I e II do ASTM E 1815, um acelerador linear Varian modelo Linatron 400 de 4 MeV e duas fontes de Cobalto-60 com atividades diferentes. Na técnica computadorizada foram utilizados as mesmas fontes de radiação, uma placa de fósforo denominada IPX e um equipamento CR-50P ambos da GE IT. Pelos resultados obtidos pode-se verificar que a radiografia digital com os equipamentos avaliados, atende satisfatoriamente os códigos e normas que são utilizadas na avaliação de peças fundidas. A técnica mostrou-se mais qualitativa quando na avaliação das descontinuidades localizadas nas seções críticas, pois o sistema RC possibilita a utilização de ferramenta de perfil de linha que fornece os valores de nível de cinza ao longo de uma trajetória linear demarcada na área da imagem da descontinuidade. Com isto, mesmo em poucos experimentos e um único sistema de RC pode-se concluir que a técnica é bastante vantajosa na detecção de descontinuidades nos processos de fabricação e que atendeu tanto os requisitos do ASTM E 272 para o cobre ou o ASME Seção VIII Divisão 1, Apêndice 7 que referenciam os padrões radiográficos conforme as normas ASTM E-186 e ASTM E-280 para aços fundidos. / In the constructions of power boilers, pressure vessels and other equipment for several industries has required the development of materials engineering technology for better processes in obtaining materials cast, forged, rolled, and others. Develop technological resources that minimize the presence of imperfections that could compromise the structural integrity of the equipment operating pressure has been a constant search both in plants and in capital goods industries phases of construction. A construction involves materials selection, design, fabrication, testing, inspection, testing, certification, and relief devices that meet the requirements of codes and standards. These requirements are increasing and establish limits for the existence of these imperfections go against the need to resort to non-destructive testing methods that enable always the best probability of detection. The processes of quality control have sought through new technologies increase their sensitivity in order to detect discontinuities of today are detected by conventional methods. In terms of non-destructive testing, requirements for conventional radiographic testing are at the limit of sensitivity of available industrial radiographic films, besides the commitment to seek a lower exposure time is always an important factor to be considered in quality, safety and productivity both in the factory and in the field. The aim of this work was to study and evaluate the technical radiography Computed (RC) compared to conventional radiography for inspection of materials, using evaluation parameters such as signal to noise ratio, spatial resolution, and tools for detectability, contrast sensitivity and grayscale, which apply in evaluations of digital images. For the evaluation of industrial radiography technique it was used a test specimen manufactured by the casting process with thickness from 75 to 150 mm, with typical defects in the process. The test specimen was X-rayed with the conventional and digital techniques. In the conventional technique were used industrial radiographic films types I and II to ASTM E 1815, a linear accelerator Varian model 400 Linatron 4 MeV and two cobalt-60 sources with different activities. In the technique computed were used the same radiation source, a phosphor plate IPX and an apparatus called CR-50P both GE IT. From the results it can be seen that with digital radiography equipment evaluated satisfactorily meets the codes and standards that are used in the evaluation of castings. The technique was more qualitative evaluation when the discontinuities located in critical sections for the system to use RC allows tool profile line shows values of gray level along a linear path demarcated in the image area discontinuity. With this, even in a few experiments a single system and RC can be concluded that the technique is quite advantageous in the detection of discontinuities in the manufacturing processes and that both met the requirements of ASTM E 272 for copper or ASME Section VIII Division 1, Appendix 7 that reference radiographic patterns according to ASTM E-186 and ASTM E-280 for steel castings.
59

[pt] ESTUDO DE VIOLACAO DE CP E FÍSICA ALEM DO MODELO PADRAO ATRAVES DE OSCILACAO DE NEUTRINOS EM DETETORES DE NOVA GERACAO / [en] PROBING CP VIOLATION AND PHYSICS BEYOND THE STANDARD MODEL IN NEUTRINO OSCILLATION BY NEW GENERATION DETECTORS

FRANCESCO PESSINA 09 February 2022 (has links)
[pt] Neste trabalho de tese investigaremos um novo método para medir a fase leptóonica de violação CP, CP , com um set up experimental chamado LiquidO e, estudaremos a possibilidade do futuro experimento Hyper-Kamiokande de pôr um limite sobre o tempo de vida do neutrino. Ambos são experimentos que detectam neutrinos de acelerador que performarão as próprias medições através do estudo do bem conhecido fenómeno da oscilação de sabor de neutrinos. O primeiro experimento considerado possui duas novas características: primeiramente utiliza como fonte de neutrino um fluxo de Vμ e Vμ produzidos por pions (pi+) em repouso a uma distância de 16 km e secondariamente vai usar uma nova forma de detecção. Essa detecção é feita utilizando cintilador liquido opaco com fibras ópticas que permitem distinguir entre e+ e e-. Nós explicaremos as principais propriedades fenomenológicas desta configuração e calcularemos a significância estatística de exclusão da hipótese CP = (0, pi), a precisão de medição de CP com 1δ de confiança estatística e também as regões permitidas no espaço dos parámetros sin2 023 - δ CP . Na segunda parte do nosso trabalho, nos concentraremos no experimento Hyper-Kamiokande, versão melhorada do experimento Super-Kamiokande que se adjudicou o prémio Nobel em 2015. Este é um detector de luz Cherenkov que utiliza um fluxo de Vμ (Vμ) com energias < 10GeV produzido no acelerador JPARC e colocado a uma distância de 295 km. Neste trabalho identificaremos este experimento como T2HK enquanto para a sua estensão na Korea, que utilizará a mesma fonte mas será colocada a 1100 km de distância, utilizaremos a sigla T2HKK. Nós introduziremos brevemente as modalidades de decaimento do neutrino que podem ser classificadas em dois tipos: um é chamado decaimento invisível, ou seja, quando o neutrino de origem decai em um estado estéril mais uma partícula escalar, e o outro e chamdo de decaimento visível, ou seja, quando o neutrino de origem decai em um autoestado de massa ativo mais uma partícula escalar. Em fim calcularemos as sensitividades no limite da vida média do autoestado V3 para os casos de decaimento visível e invisível para as configurações de T2HK e T2HKK. / [en] In this thesis we will study a novel method to measure the leptonic CP violation phase, CP , in an experimental set up called LiquidO, and the possibility by the future experiment Hyper-Kamiokande to put a limit on the neutrino lifetime. Both experiment are accelerator based ones that will use the well established neutrino flavour oscillation phenomenon to perform their measurement. The first experimental set up uses two new features: firstly it uses as a source a flux of Vμ and Vμ coming from pions (pi+) decay at rest with a baseline of 16 km and secondly it uses a new detection method. This new detection is performed using opaque Liquid Scintillator (LS) with optical fibers that allows e+ e- identification. We will discuss the phenomenological main characteristics of this set up and we will calculate the expected significance to exclude the δ CP = (0, pi) hypothesis, the 1δ precision of the CP measurement and also the expected allowed regions in the sin2 023 - δ CP plane. For what it concerns the second part of our work, we will focus on the Hyper-Kamiokande experiment, upgrade of the 2015 Nobel prize awarded Super-Kamiokande. This is a water Cherenkov detector that will use a Vμ (Vμ) flux with a typical neutrino energy < 10 GeV coming from the JPARC facility with a baseline of 295 km. We will call this source-detector configuration T2HK to distinguish T2HKK, the possible extension of this experiment in Korea that will use the same beam but it will be located at 1100 km from the source. We will briefly introduce the neutrino decay mode that can be classified in two types: one is what is called invisible decay , i.e. when neutrino decays into a sterile neutrino state plus a scalar particle, and the other is called visible decay, i.e. when neutrino decays into an active mass eigenstate plus a scalar particle. We will calculate the limit on the V3 lifetime for the invisible and the visible case for both configurations T2HK and T2HKK.
60

Vida-média do estado isomérico 7(-) do núcleo ímpar-ímpar 68Ga / Lifetime of the 7(-) isomeric state of the odd-odd nucleus 68Ga

Escudeiro, Rafael 13 April 2018 (has links)
Estados Nucleares isoméricos são estados que decaem com vidas-médias longas ( T1/2 > 10 ns) e revelam, em geral, uma grande mudança no momento angular no seu decaimento, um pequeno elemento de matriz ou uma baixa energia de transição. Através da medida da vida-média de estados nucleares é possível obter informações sobre a função de onda desse estado, representando um teste rigoroso para modelos nucleares. Neste trabalho foi utilizado um sistema desenvolvido no Laboratório Aberto de Física Nuclear (LAFN) da Universidade de São Paulo chamado SIStema para Medida de Estados Isoméricos (SISMEI), que utiliza coincidência atrasada entre partículas evaporadas numa reação nuclear e raios gama emitidos pelo estado isomérico. O SISMEI consiste de cintiladores plásticos para detecção das partículas, detectores de germânio hiperpuro (HPGe) e iodeto de sódio (NaI(Tl)) para raios gama, associados a uma eletrônica de coincidência, instalado no acelerador Pelletron (8UD) do LAFN. Neste trabalho, realizou-se um experimento para medir o estado isomérico 7(-) (E = 1229,87(4) keV) do 68Ga. A tomada de dados durou cerca de 80 horas com uma taxa de eventos de aproximadamente 80000 contagens por hora. O resultado obtido foi T 1/2 = 60, 8(11) ns, que é compatível com os resultados experimentais de outros trabalhos, porém, mais preciso. A estrutura desse núcleo foi calculada através do Modelo de Camadas em Larga Escala considerando-se duas interações residuais diferentes FPG e JUN45; os resultados foram comparados entre si, juntamente com os valores obtidos em outros trabalhos. Os cálculos realizados com o Modelo de Camadas reproduziram relativamente bem a energia e a ordem dos estados excitados do 68Ga, a interação FPG conseguiu descrever melhor a probabilidade de transição quadrupolar elétrica B(E2) diretamente ligada à vida-média do estado. / Isomeric nuclear states are nuclear states which decay with long lifetimes (T1/2 > 10 ns); their study generally reveals, a large change in angular momentum in its decay, a small matrix element or a small transition energy. By measuring lifetimes of isomeric states it is possible to obtain information about this states wave function, being a robust test for nuclear models. In this work, a system developed at the Laboratório Aberto de Fsica Nuclear (LAFN) of University of São Paulo called System for the Measurement of Isomeric States (SISMEI) was utilized. Delayed coincidence between evaporated particles in a nuclear reaction and the delayed gamma-rays emitted from the isomeric state was used to measure lifetimes. SISMEI is composed of plastic scintillators for particle detection, hiperpure germanium detectors (HPGe) and sodium iodide (NaI(Tl)) for gamma-ray detection, coupled to a coincidence system, located on 30A beam line of the Pelletron (8UD) accelerator - LAFN. In the present work, an experiment to measure the 7 (-) (E = 1229.87(4) keV) isomeric state of 68Ga was performed. The experiment took about 80 hours with an event rate of about 80000 counts per second. The measured value was T 1/2 = 60.8(11) ns, which is compatible, but more accurate, with experimental results of other authors. The nuclear structure of this nucleus was calculated with the Large Scale Shell Model by using two different residual interactions FPG and JUN45; the results were compared with the known values. The structure calculated with LSSM described the energy states and the order of excited states relatively well; the FPG interaction was capable to describe better the quadrupolar electrical transition probability B(E2), which is direct related to predicting the state lifetime.

Page generated in 0.0586 seconds