51 |
Estudo clínico randomizado e duplo-cego do Biosilicato sob restaurações de resina composta em dentes afetados por cárie / Double-blind, randomized clinical trial of Biosilicate under resin composite restorations in caries affected teethPalomino, Karen Pintado 22 June 2017 (has links)
O presente estudo teve por objetivo avaliar o efeito de um biomaterial vitrocerâmico (Biosilicato®) no desempenho clínico de restaurações posteriores em resina composta. 92 cavidades Classe I e Classe II com lesão de cárie (no terço meio da dentina) foram selecionadas e distribuídas aleatoriamente em quatro grupos segundo o protocolo adesivo: 1- Biosilicato / sistema adesivo convencional de dois passos, 2- Controle / sistema adesivo convencional de dois passos, 3- Biosilicato / sistema adesivo autocondicionante de dois passos e 4- Controle / sistema adesivo autocondicionante de dois passos. Dois operadores realizaram os protocolos adesivos e restauraram as cavidades com uma resina composta nanohíbrida (IPS Empress, Ivoclar) usando a técnica incremental. Os participantes foram remarcados após uma semana, 6, 12 e 18 meses para avaliação clínica realizada por dois examinadores, cegados e calibrados de acordo com os critérios FDI. Os dados foram analisados com o teste não paramétrico de Kruskal-Wallis e o teste de Dunn de comparação múltipla, com nível de significância de 5%. Os resultados revelaram que não houve diferença estatisticamente significante (p > 0.05) entre os grupos experimentais e os respectivos controles em nenhuma avaliação, entretanto, houve diferença estatisticamente significativa (p < 0.05) entre os grupos controles (2 x 4) para o critério forma anatômica (1 semana) e adaptação marginal (18 meses). O grupo 2 foi estatisticamente diferente do grupo 3 (p < 0.05), para o critério fratura do material/retenção (18 meses) e adaptação marginal (1 semana), onde o grupo 2 apresentou melhor desempenho. O uso do Biosilicato no protocolo restaurador de dentina afetada por cárie não alterou o desempenho clinico de restaurações em resina composta no período de 18 meses de acompanhamento. A associação entre o sistema adesivo autocondicionante de dois passos e o Biosilicato gerou desempenho clínico inferior, comparado ao sistema adesivo convencional (controle), em termos de adaptação marginal e fratura do material/retenção. / The aim of this study was to evaluate the effect of a bioactive glass-ceramic (Biosilicate®) on clinical performance of posterior resin composite restorations. A total of 92 restorations in Class I and Class II cavities with carious lesion (medium third of dentin) were selected and assigned randomly into four groups according to the adhesive protocol used: 1- Biosilicate / Two-step etch and rinse system, 2- Control / Two-step etch and rinse system, 3- Biosilicate / Two-step self-etching system and 4- Control / Two-step self-etching system). Two operators carried out the adhesive protocols and restored the cavities with a nano-hybrid resin composite (IPS Empress, Ivoclar) using the incremental technique. Participants were recalled at one week, 6, 12 and 18 months for clinical evaluation performed by two blinded examiners and calibrated according to FDI criteria. Data were analyzed using Krusall-Wallis non-parametric test and multiple comparison Dunn test with a significance level of 5%. Results showed no statistical difference (p > 0.05) between the experimental groups and their respective controls; however, there were statistical difference between control groups (2 x 4) (p < 0.05) for anatomical form (1 week) and marginal adaptation (18 months). Group 2 was statistically different from Group 3 (p < 0.05), for fracture of material/retention (18 months) and marginal adaptation category (1 week), where Group 2 showed the better performance. The use of Biosilicate, in a restorative protocol for caries-affected dentin, did not alter the clinical performance of posterior resin composite restorations. The association between Biosilicate and two-step self-etching adhesive system showed an inferior clinical performance, compared to the conventional adhesive system (control), in terms of marginal adaptation and fracture of material/retention.
|
52 |
Estudo longitudinal da resistência e qualidade de união de diferentes sistemas adesivos à dentina irradiada com laser de femtossegundos / Long term evaluation of bond strength and quality of the interface of different adhesive systems to femtosecond laser irradiated dentinSimone Gonçalves Moretto 17 December 2012 (has links)
Recentemente, os lasers de pulsos ultracurtos têm sido avaliados para o preparo dos tecidos duros dentais devido à sua habilidade de reduzir os efeitos térmicos resultantes da irradiação. O objetivo deste estudo foi avaliar a efetividade de união de 3 sistemas adesivos à dentina preparada com o laser de femtossegundos (10-15 s). Para isso, 60 terceiros molares foram preparados com o laser de femtossegundos (1.450 nm; 0,3W; 100.000Hz) ou ponta diamantada, divididos em 3 subgrupos (n=10) restaurados utilizando o adesivo condicione e lave de 3 passos Optibond FL (OFL; Kerr), o autocondicionante de 2 passos Clearfil SE (CSE; Kuraray) ou o autocondicionante de 1 passo G-aenial Bond (GAB; GC). Após 1 semana de armazenamento em água, os dentes foram seccionados (1,0x1,0 mm) e testados imediatamente e após 6 meses de armazenamento. Vinte e quatro amostras adicionais foram preparadas com o laser ou ponta diamantanda conforme descrito acima. Seis amostras foram seccionadas em espécimes menores e aleatoriamente preparados para observação das características morfológicas da superfície (n=3) e subsuperfície (n=3) em Microscópio Eletrônico de Varredura (MEV) (n=3) e Microscopia Eletrônica de Transmissão (MET) (n=3). As outras 18 amostras foram restauradas com os sistemas adesivos supramencionados, seccionados em espécimes menores e distribuídos para avaliação da interface adesiva em MEV (n=3) e padrão de nanoinfiltração após 1 semana (n=2) e 6 meses (n=2) em MET. O modelo linear de efeitos mistos (=0,05) revelou um efeito significante dos fatores adesivo, armazenagem e a interação preparo x armazenagem na resistência de união. Todos os adesivos apresentaram uma redução significante da resistência de união após 6 meses de armazenamento (p<0,0001) para ambos os tipos de preparo. Com relação ao sistema adesivo, a única diferença verificada foi o maior valor de resistência de união do GAB quando aplicado sobre as superfícies irradiadas (56,71±10,72 MPa) quando comparadas com as preparadas com ponta diamantada (43,14±14,93 MPa) após 1 semana de armazenamento. A análise de fratura revelou fraturas mistas, adesivas e coesivas em dentina para ambos os métodos de preparo com um discreto aumento do número de fraturas mistas após 6 meses de armazenamento exceto para o GAB, que apresentou principalmente fraturas adesivas e mistas. A análise em MEV revelou uma fina camada de debris sobre a superfície da dentina irradiada e a hibridização com todos os sistemas adesivos resultou num íntimo contado da interface adesiva com o substrato. A análise em MET da subsuperfície irradiada revelou fibrilas colágenas preservadas. A análise da interface adesiva revelou um aumento dos depósitos de prata na camada híbrida para todos os adesivos, após 6 meses de armazenamento, independentemente do tipo de preparo. Apenas o GAB apresentou maiores depósitos de prata após 1 semana de armazenamento para as superfícies preparadas com ponta diamantada. A irradiação com o laser de femtossegundos não reduziu a receptividade da dentina aos sistemas adesivos, resultando em valores de resistência de união similares aos obtidos com a ponta diamantada; além de uma ótima interação do substrato com os sistemas adesivos e deposições de prata similares àquelas obtidas com a ponta diamantada. / Recently, the applicability of ultrashort pulsed lasers has been studied for dental hard-tissue irradiation because of its reduced residual thermal damage. The aim of this study was to determine the bonding effectiveness of 3 contemporary adhesive systems to dentin prepared by femtosecond (10-15 sec) laser-irradiation. For this, 60 third molars were prepared either by the femtosecond laser (1450 nm; 0.3W; 100,000Hz) or by bur, randomly divided into 3 subgroups (n=10) and restored with a composite using either the 3-step etch-and-rinse adhesive Optibond FL (OFL; Kerr), the 2-step self-etch adhesive Clearfil SE (CSE; Kuraray) or the 1-step self-etch adhesive G-aenial Bond (GAB; GC). After 1-week water storage, the teeth were sectioned (1.0x1.0 mm) and half of the specimens were tested until failure using a micro-tensile bond-strength (TBS) approach. The other half was stored in water and tested after 6 months. Twenty-four additional dentin samples were exposed to the diamond bur and the laser, following the same abovementioned parameters. Three samples of each treatment were sectioned in smaller specimens in order to be characterized for surface (n=3) and cross-sectional morphological analysis using Scanning Electron Microscopy (SEM) (n=3) and Transmission Electron Microscopy (TEM) (n=3). The other eighteen samples were hybridized with the abovementioned adhesive systems, sectioned in smaller samples and distributed for evaluation of the interface under SEM (n=3) and nanoleakage distribution for 1 week (n=2) and 6 months (n=2) under TEM. Linear mixed effect model (=0.05) revealed a significant effect of the factors adhesive, storage and the interaction of preparation x storage on the TBS. All adhesives presented a significant reduction of the bond strength after 6-month storage (p<0.0001) for both preparation methods. Regarding the adhesive system, the only difference found was a significantly higher TBS of GAB to laser-irradiated (56.71±10.72 MPa) than to bur-cut dentin (43.14±14.93 MPa) after 1-week water storage. Fracture analysis showed mixed, adhesive and cohesive failures in dentin similarly for both preparation methods with a slightly increase of the mixed failures after 6-months water storage for OFL and CSE, but not for GAB that presented mainly adhesive and mixed failures. SEM disclosed a thin layer of debris on the laser-irradiated dentin surface and the hybridization with all adhesive systems resulted in a very tight interface. TEM analysis of the irradiated subsurface revealed collagen fibrils preserved and for the nanoleakage evaluation an increase of silver deposits at hybrid layer for all adhesives testes after 6-months water storage, irrespective of the preparation methods. Only the GAB presented great silver deposits even after 1-week water storage for the bur-cut preparation method. Femtosecond laser irradiation did not reduce the bonding receptiveness of dentin resulting in similar values obtained with the preparation by bur. Additionally it led to a great interaction with different adhesive systems and silver deposits comparable to those obtained with the bur-cut preparation method.
|
53 |
Influência da irradiação com laser de Er, Cr:YSGG na resistência de união de sistemas adesivos em esmalte e dentina / Er,Cr:YSGG laser irradiation influence on enamel and dentin bond strength of adhesive systemsBotta, Sergio Brossi 04 June 2007 (has links)
Este trabalho teve o objetivo de avaliar a resistência adesiva de sistemas adesivos baseados no condicionamento prévio com ácido fosfórico (etch-and-rinse) e auto-condicionantes (de um e dois passos) ao substrato dental, submetido a diferentes condições de irradiação com laser de Er,Cr:YSGG. Amostras de esmalte e dentina foram obtidas do terço médio da face vestibular de 216 incisivos bovinos, divididos aleatoriamente em 18 grupos (n=12), de acordo com o substrato, (esmalte e dentina), sistema adesivo (etch-and-rinse, auto-condicionante de um passo e auto-condicionante de dois passos) e condições de irradiação (sem irradiação ? controle, irradiado com refrigeração ar-água e irradiado sem refrigeração ar-água). Em seguida foi realizada inclusão e polimento, sob refrigeração, com lixas de carbeto de silício de granulação decrescente 180, 320, 400 e 600 (por um minuto para padronização da camada de esfregaço). Para os grupos irradiados com laser de Er,Cr:YSGG (?=2,79 ?m, taxa de repetição de 20 Hz), com densidade de energia de 2,8 J/cm2, 12,5 mJ por pulso, potência média de 0,25W, com a ponta S75 de diâmetro de 750 ?m a 1 mm da superfície do substrato. A condição de refrigeração da irradiação foi realizada com 11 mL/min. Os corpos-de-prova foram confeccionados com a resina composta Filtek Z250, em forma de cone invertido para realização do teste de resistência adesiva. Após 24 h de armazenagem em água destilada a 37ºC, fez-se o ensaio de tração a 0,5 mm/min. Os dados foram comparados estatisticamente pelo método de ANOVA com significância de 5%. Os resultados obtidos mostraram que para o tecido esmalte foi observada diferença estatisticamente significante para os fatores adesivo e condições de irradiação empregadas, sem significância para a interação entre os fatores. A resistência de união do sistema adesivo auto-condicionante de dois passos e do sistema adesivo etch-and-rinse apresentam desempenho semelhante, sendo superiores ao sistema adesivo auto-condicionante de passo único. Ainda para esmalte, o efeito das condições de irradiação mostrou que os grupos sem irradiação com laser de Er,Cr:YSGG apresentaram maior resistência adesiva do que os grupos irradiados com refrigeração e sem refrigeração. Para o substrato dentina, houve diferença estatisticamente significante para os fatores de variação principais: sistemas adesivos, condição de irradiação com laser de Er,Cr:YSGG e para a interação adesivo X condição de irradiação. Quanto à comparação entre os sistemas adesivos testados na condição sem irradiação, os sistemas adesivos auto-condicionantes, de dois passos e o de um passo, não foram estatisticamente diferentes entre si, porém ambos forneceram resultados de resistência adesiva estatisticamente menores do que o sistema adesivo etch-and-rinse. Para as condições de irradiação com laser de Er,Cr:YSGG, com refrigeração e sem refrigeração, obteve-se valores de resistência adesiva maiores para o sistema auto-condicionante de dois passos do que para os demais sistemas. Deste modo, conclui-se que a irradiação com laser de Er,Cr:YSGG reduz a adesão ao esmalte independentemente do sistema adesivo utilizado e da condição de irradiação. Adicionalmente, observa-se que a irradiação de dentina com laser de Er,Cr:YSGG somente não altera a resistência adesiva do sistema auto-condicionante de dois passos, sendo deletéria aos demais adesivos testados. / The aim of this study was to assess the bond strength to dental substrate of adhesives based on previous etching with phosphoric acid (etch-and-rinse) and self-etching (one- and two-step) under different conditions of Er,Cr:YSGG laser irradiation. Enamel and dentin samples were obtained from the middle third of the buccal face of 216 bovine incisors, randomly divided in 18 groups (n=12), according to the substrate (enamel and dentin), adhesive system (etch-and-rinse, one-step self-etching and two-step self-etching) and irradiation condition (without irradiation ? control, irradiated with cooling, and irradiated without cooling). Next, the samples were included and polished, under cooling, with silicone carbide abrasive papers of decreasing grit #180, 320, 400 and 600 (for one minute to standardize the smear layer). For the irradiated groups with Er,Cr:YSGG laser, an energy density of 2.8 J/cm2, 12.5 mJ per pulse, mean power of 0.25W was selected. During laser irradiation, cooling was performed with 11 mL/min. Inverted cone-shaped test specimens were built-up with resin composite Filtek Z250, for performing the bond strength test. After 24 h storage in distilled water at 37ºC, the tensile test was performed at 0.5 mm/min. The results obtained show, for enamel, statistically significant difference for the factors adhesive and irradiation conditions used, without significance for the interaction among the factors. The bond strength of the 2-step self-etching and the etch-and-rinse adhesive system presented similar performance, being superior to that of one-step self-etching system. For enamel, the effect of the irradiation conditions showed that the groups without Er,Cr:YSGG laser irradiation presented higher bond strength than the groups irradiated with and without cooling. For the dentin substrate there was statistically significant difference for the main variation factors: adhesive systems, condition of Er,Cr:YSGG laser irradiation and for the interaction adhesive X irradiation condition. As regards the comparison among the adhesive systems tested under the condition without irradiation, the one-step and two-step self-etching adhesive systems did not differ statistically between them, but both provided statistically lower bond strength results than the etch-and-rinse adhesive system. For the condition of Er,Cr:YSGG laser irradiation with and without cooling, higher bond strength values were obtained for the two-step self-etching system than for the other systems. Therefore, it was concluded that Er,Cr:YSGG laser irradiation reduces the bond strength to enamel irrespective of the adhesive system used and the irradiation condition. Furthermore, it was observed that dentin irradiated with Er,Cr:YSGG laser did not alter the bond strength of the two-step adhesive system only, and it was deleterious to the other adhesives tested.
|
54 |
Difusão transdentinária e citotoxicidade de sistemas adesivos autocondicionantesLanza, Célia Regina Moreira [UNESP] 06 July 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:01Z (GMT). No. of bitstreams: 0
Previous issue date: 2007-07-06Bitstream added on 2014-06-13T19:43:57Z : No. of bitstreams: 1
lanza_crm_dr_arafo.pdf: 5945078 bytes, checksum: 092aa2094ca72bbfeb2e0b5301a1b69e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo avaliou a difusão transdentinária e a toxicidade de sistemas adesivos autocondicionantes de diferentes valores de pH sobre células odontoblastóides MDPC-23. Sessenta discos de dentina (0,4 mm de espessura) foram obtidos de terceiros molares humanos hígidos e divididos em 6 grupos após a mensuração de sua condutância hidráulica pelo Flodec. Os discos foram montados em câmaras pulpares in vitro, onde 30.000 células foram plantadas no seu lado pulpar (área dentina exposta 0,28 cm2) e mantidas em cultura por 48 h. Após este período, os sistemas adesivos Clearfil SE Bond, Clearfil Protect Bond, Adper Prompt e Xeno III foram aplicados no lado oclusal dos discos. O sistema adesivo Single Bond foi usado como controle positivo e a solução tampão fosfato como controle negativo. A citotoxicidade foi avaliada após 24 horas pelo teste MTT e a morfologia celular por MEV. A difusão transdentinária foi qualificada por CG/EM. Os valores de MTT para os sistemas autocondicionantes, analisados pelos testes de Kruskall-Wallis e Mann-Whitney, foram estatisticamente diferentes do grupo controle negativo. Houve redução da viabilidade celular de 47,8%; 46,5%; 42,1% e 28,0% para o Clearfil SE Bond, Xeno III, Clearfil Protect Bond e Adper Prompt L-Pop, respectivamente. A redução da viabilidade celular foi inferior ao Single Bond (53,1%) para todos os sistemas. A análise por CG/MS identificou o HEMA como principal componente químico difundido pela dentina. Foi possível concluir que todos os sistemas adesivos autocondicionantes avaliados apresentaram difusão transdentinária resultando em redução do metabolismo celular, a qual não foi relacionada a sua capacidade de dissolução da smear layer e desmineralização da dentina subjancente. / This study evaluated the transdentinal diffusion and cytotoxicity of self-etching adhesive systems with different pH on the odontoblast cell line MDPC-23. Sixty dentin disks were cut from the crowns of extracted human permanent molar teeth with 0.4 mm thickness and were divided into 6 groups of similar hydraulic conductance (Flodec). The dentin disks were placed in an in vitro pulp chamber and 30.000 cells were planted on their pulpal side (area of exposed dentin 0.28 cm2). After 48 hours, the adhesive systems Clearfil SE Bond, Clearfil Protect Bond, Adper Prompt or Xeno III were applied on the occlusal side and light-cured for 10s. Single Bond was used as positive and phosphate buffer solution (PBS) as negative control group. The cytotoxicity was measured by MTT assay and cell characteristics were assessed by SEM, after 24 h. The transdentinal diffusion was qualified by GC/MS. Kruskall-Wallis and Mann-Whitney tests demonstrated a significant difference among the adhesives and PBS (p<0.05). The cellular viability reduction promoted by the self-etching systems was lower than that of Single Bond (53,1%). Cell metabolism was reduced in 47,8%; 46,5%; 42,1% and 28,0% for Clearfil SE Bond, Xeno III, Clearfil Protect Bond and Adper Prompt, respectively. HEMA was identified as the main diffused component. It was concluded that all investigated self-etching adhesives demonstrated transdentinal diffusion resulting in reduction of the cellular metabolism, which was not related to their capacity to dissolve the smear layer and demineralize the underlying dentin.
|
55 |
Difusão transdentinária e citotoxicidade de sistemas adesivos autocondicionantes /Lanza, Célia Regina Moreira. January 2007 (has links)
Orientador: Josemeri Hebling / Banca: Roberval de Almeida Cruz / Banca: José Carlos Pereira / Banca: Elisa Maria Aparecida Giro / Banca: Carlos Alberto dos Santos Cruz / Resumo: Este estudo avaliou a difusão transdentinária e a toxicidade de sistemas adesivos autocondicionantes de diferentes valores de pH sobre células odontoblastóides MDPC-23. Sessenta discos de dentina (0,4 mm de espessura) foram obtidos de terceiros molares humanos hígidos e divididos em 6 grupos após a mensuração de sua condutância hidráulica pelo Flodec. Os discos foram montados em câmaras pulpares in vitro, onde 30.000 células foram plantadas no seu lado pulpar (área dentina exposta 0,28 cm2) e mantidas em cultura por 48 h. Após este período, os sistemas adesivos Clearfil SE Bond, Clearfil Protect Bond, Adper Prompt e Xeno III foram aplicados no lado oclusal dos discos. O sistema adesivo Single Bond foi usado como controle positivo e a solução tampão fosfato como controle negativo. A citotoxicidade foi avaliada após 24 horas pelo teste MTT e a morfologia celular por MEV. A difusão transdentinária foi qualificada por CG/EM. Os valores de MTT para os sistemas autocondicionantes, analisados pelos testes de Kruskall-Wallis e Mann-Whitney, foram estatisticamente diferentes do grupo controle negativo. Houve redução da viabilidade celular de 47,8%; 46,5%; 42,1% e 28,0% para o Clearfil SE Bond, Xeno III, Clearfil Protect Bond e Adper Prompt L-Pop, respectivamente. A redução da viabilidade celular foi inferior ao Single Bond (53,1%) para todos os sistemas. A análise por CG/MS identificou o HEMA como principal componente químico difundido pela dentina. Foi possível concluir que todos os sistemas adesivos autocondicionantes avaliados apresentaram difusão transdentinária resultando em redução do metabolismo celular, a qual não foi relacionada a sua capacidade de dissolução da smear layer e desmineralização da dentina subjancente. / Abstract: This study evaluated the transdentinal diffusion and cytotoxicity of self-etching adhesive systems with different pH on the odontoblast cell line MDPC-23. Sixty dentin disks were cut from the crowns of extracted human permanent molar teeth with 0.4 mm thickness and were divided into 6 groups of similar hydraulic conductance (Flodec). The dentin disks were placed in an in vitro pulp chamber and 30.000 cells were planted on their pulpal side (area of exposed dentin 0.28 cm2). After 48 hours, the adhesive systems Clearfil SE Bond, Clearfil Protect Bond, Adper Prompt or Xeno III were applied on the occlusal side and light-cured for 10s. Single Bond was used as positive and phosphate buffer solution (PBS) as negative control group. The cytotoxicity was measured by MTT assay and cell characteristics were assessed by SEM, after 24 h. The transdentinal diffusion was qualified by GC/MS. Kruskall-Wallis and Mann-Whitney tests demonstrated a significant difference among the adhesives and PBS (p<0.05). The cellular viability reduction promoted by the self-etching systems was lower than that of Single Bond (53,1%). Cell metabolism was reduced in 47,8%; 46,5%; 42,1% and 28,0% for Clearfil SE Bond, Xeno III, Clearfil Protect Bond and Adper Prompt, respectively. HEMA was identified as the main diffused component. It was concluded that all investigated self-etching adhesives demonstrated transdentinal diffusion resulting in reduction of the cellular metabolism, which was not related to their capacity to dissolve the smear layer and demineralize the underlying dentin. / Doutor
|
56 |
Influência da concentração de clorexidina em relação ao tempo e meio de armazenagem na resistência de união de sistemas adesivosDutra, Marília Cherulli 18 February 2011 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Significant technological advances in dental materials and chemicals
have occurred in recent decades, contributing to increased longevity of
adhesive restorations. The aim of this study was to evaluate the influence of the
chlorhexidine concentration, time and storage condition on the microtensile
bond strength of adhesive systems. The study was conducted in two stages; for
the first analysis of this study, thirty noncarious human molars were sectioned to
expose middle-coronal dentin, which was etched with 37% phosphoric acid.
Specimens were randomly assigned to the following treatments with
chlorhexidine digluconate (CHX) (n=10): group C (control), not treatment was
done; group 0.12Chx, aqueous solutions of 0.12% Chx; group 2CHX, aqueous
solutions of 2% CHX. Each group was subdivided in accordance with adhesive
systems (n=5): SC, Adper Scothbond Multi-Purpose; and XP, XP Bond. All
were restored with resin composite Filtek Z350 XT. Resin-dentin sticks with
cross-sectional area approximately of ±1.0mm2 were submitted to microtensile
bond strength (μTBS) test immediately (T0) and after 4 months of storage in
artificial saliva (T4). For the second analysis this study, a flat middle dentin
surface was prepared on 15 extracted human molars and was etched with 37%
phosphoric acid. Specimens were randomly divided according to the treatments
with CHX (n=10): Np, no pretreatment; 0.12CHX, aqueous solutions of 0.12%
CHX; 2CHX, aqueous solutions of 2% CHX. All specimens were bonded with
Adper Scothbond Multi-Purpose and restored with resin composite Filtek Z350
XT. Resin-dentin sticks with cross-sectional area of approximately ±1.0mm2
were submitted to microtensile bond strength test immediately (T0) and after 4
months of storage (T4) in mineral oil. The results of this second analysis were
compared with the results of the groups that used the Adper Scothbond Multi-
Purpose adhesive system of the first evaluation. The data were submitted to
statistical analysis by 3-way analysis of variance (ANOVA) and the Tukey
Honestly Significant Difference (HSD) test (α=.05). Results of first evaluation
showed statistically significant differences on bond strength values to aging
factor (p<.001) and adhesive factor (p<.001). The failure mode was analyzed by Fisher s Exact Test, which demonstrated significant differences within the
groups; prevalence of mixed in T0 and adhesive failure after aging to SC
groups, except the groups treated with 2% CHX; and XP groups had a
prevalence of adhesive failures at T0 and mixed failures in T4, except the groups
treated with 2% chlorhexidine. For the second evaluation, was found statistically
significant differences between the bond strength of storage media (p < .001)
and between aging versus the storage media (p<.001). Fisher s Exact Test
demonstrated significant differences between the failure mode within the
groups; prevalence of mixed and adhesive failure. Therefore, the use of
chlorhexidine did not influenced the bond strength values of the adhesive
systems tested, however of 2% CHX showed influence in the dental structure.
Differences in adhesives systems were detected, which 3-step etch-and-rinse
adhesive presented higher bond strength values than 2-step etch-and-rinse
adhesive; and after 4 months of aging, the bond strength values were lower,
regardless of the adhesive system tested. Specimens stored in artificial saliva
long-term showed interface degradation by hydrolysis and reduction on bond
strength, unobserved characteristics in mineral oil storage. / Significantes avanços tecnológicos e químicos de materiais
odontológicos ocorreram nas últimas décadas, contribuindo para aumento da
longevidade de restaurações adesivas. O objetivo deste estudo foi avaliar a
influência da concentração de clorexidina, tempo e diferentes meios de
armazenagem na resistência de união de sistemas adesivos à dentina, por
meio de ensaio mecânico de microtração. O estudo foi realizado em duas
etapas; na primeira etapa 30 terceiros molares humanos íntegros foram
selecionados. O esmalte oclusal foi seccionado, expondo dentina média, a qual
foi condicionada com ácido fosfórico 37%. Os espécimes foram divididos em
três grupos (n=10) de acordo com o tratamento da dentina com diferentes
concentrações de digluconato clorexidina (CHX), sendo: grupo C (controle),
não recebeu tratamento com clorexidina; grupo 0,12Chx, aplicação de CHX a
0,12% durante 60 s; e grupo 2Chx, aplicação de CHX 2% por 60 s.
Posteriormente, cada grupo foi subdividido em dois grupos (n=5) de acordo
com o sistema adesivo utilizado: SC, Adper Scothbond Multi-Purpose, e XP, XP
Bond. Todos os espécimes foram restaurados com resina composta Filtek
Z350 XT; e seccionados em palitos de área de seção de ±1 mm2. Estes foram
submetidos ao ensaio de microtração imediatamente (T0) e após 4 meses de
armazenagem (T4) em saliva artificial. Para segunda análise deste estudo, 15
terceiros molares humanos íntegros tiveram a superfície oclusal seccionada e
condicionada com ácido fosfórico 37%. Os dentes foram divididos em três
grupos (n=5) de acordo com o tratamento da dentina com clorexidina: Np
(controle), não recebeu tratamento com clorexidina; 0,12CHX, tratamento
dentinário com solução de clorexidina a 0,12% durante 60 s; e 2CHX,
tratamento com clorexidina a 2% por 60 s. Os espécimes receberam aplicação
de sistema adesivo Adper Scothbond Multi-Purpose e foram restaurados com
resina composta Filtek Z350 XT. Palitos de resina/dentina de ±1 mm2 foram
seccionados e submetidos ao ensaio de microtração imediatamente (T0) e após
4 meses de armazenagem (T4) em óleo mineral a 37ºC. Os resultados desta
segunda análise foram comparados com os resultados dos grupos em que foi utilizado o sistema adesivo Adper Scothbond Multi-Purpose da primeira análise.
Os dados obtidos foram estatisticamente analisados pela análise de variância
fatorial e teste de Tukey (α = 0,05). Os resultados da primeira análise
mostraram diferença estatisticamente significante nos valores de resistência de
união para o fator envelhecimento (p<0,001) e fator adesivo (p<0,001). O
padrão de falha foi analisado pelo Teste Exato de Fisher, o qual mostrou
diferença estatística dentro dos grupos; prevalecendo falha mista em T0 e falha
adesiva após envelhecimento para os grupos SC, exceto os grupos tratados
com CHX a 2%; e os grupos XP apresentaram prevalência de falhas adesivas
em T0 e falhas mistas em T4, exceto os grupos tratados com clorexidina 2%. Na
segunda análise deste estudo foi encontrada diferença estatisticamente
significante para o meio de armazenagem (p<0,001), e entre envelhecimento e
meio de armazenagem (p<0,001). Teste Exato de Fisher mostrou diferença
significante no padrão de falha dentro de cada grupo; e prevalência de falhas
mistas e adesivas. Portanto, o uso de clorexidina não influenciou nos valores
de resistência de união dos sistemas adesivos testados, no entanto a CHX 2%
mostrou ter influência no padrão de fratura. Diferença na resistência de união
dos sistemas adesivos foi detectada, sendo que o adesivo de 3 passos
apresentou maiores valores. E espécimes armazenados em saliva artificial
apresentaram degradação da interface resina/dentina e redução na resistência
de união, características não encontradas nos grupos armazenados em óleo
mineral. / Mestre em Odontologia
|
57 |
Dlouhodobá odolnost okrajového uzávěru kompozitních výplní v prostředí se zvýšeným korozním rizikem / Long-term durability of composite restoration margins in environments with increased corrosion riskRoubíčková, Adéla January 2013 (has links)
Introduction: An adhesive bond between hard dental tissues and composite reconstructions is exposed to mechanical load, water, bacteria, enzymes and different chemical compounds. These factors could impair durability and resistance of composite reconstructions. In contrast with extensive research of negative influence of water on degradation of adhesive bonds, the influence of chemical substances on adhesive bond has not been investigated to a greater extent. Aim: The aim of the experimental part of the thesis was to evaluate the influence of hydrogen peroxide containing tooth-whitening products and mouth rinses containing chlorhexidine and fluoride on a long-term stability of class V composite restorations created using four contemporary adhesive systems by a microleakage method. Materials and methods: The following adhesive systems were investigated: total-etch Gluma Comfort Bond (GLU), and self-etch adhesives Clearfil SE Bond (CLF), Adper Prompt (ADP) and iBond (IBO). Standardized class V cavities were prepared in 192 extracted human teeth (one cervical margin in the cementum and one in the enamel). Subsequently, the cavities were restored using microhybride composite Charisma. The specimens were then exposed to the tooth whitening system Opalescence PF 20, mouth rinse Corsodyl containing...
|
58 |
Influência de adesivos autocondicionantes na resistência adesiva de cimentos de ionômero de vidro resinomodificados à dentina / Influence of self-etch adhesive on bond strength of resin-modified glass ionomer to dentinGiovanna Emann Tavares Menegatti 12 May 2016 (has links)
A presente pesquisa se propôs a avaliar a influência de cinco tratamentos dentinários na resistência de união à dentina de quatro cimentos de ionômero de vidro modificados por resina (CIVRMs). O ensaio experimental foi realizado in vitro, fazendo uso de 200 incisivos bovinos. Destes, foram obtidos 200 fragmentos de dentina, que foram distribuídos aleatoriamente em 20 grupos (n=10), segundo os fatores de variação que compreendem cinco tratamentos dentinários (Grupo controle, ou seja, sem tratamento; Ácido Poliacrílico a 20%, Clearfil SE Bond; Single Bond Universal e Primer do Vitremer) e quatro cimentos ionoméricos (GC Fuji II LC® CAPSULE; GC Fuji LINING® LC (Paste Pak); Vitrebond® e Vitremer). Após a confecção dos corpos de prova e 24h de armazenamento em estufa à 37oC, foi realizado o teste de microcisalhamento na máquina de ensaios universal (Instron 5942 - Canton, MA, EUA) com velocidade de 1mm/min, seguido da análise do padrão de fratura em microscópio digital. A análise estatística dos 400 resultados obtidos foi feita por meio do teste paramétrico ANOVA para dois fatores de variação (cimento e tratamento) (p<0,05%) e pelo teste auxiliar de Tukey (p<0,05%). Os testes estatísticos demonstraram haver diferença estatística tanto entre os tratamentos, como entre os cimentos e na interação de ambos (p<0,0001). Os sistemas adesivos Clearfil SE (X?=18,26 ± 2,78) e SingleBond (X?=17,28 ± 2,49) promoveram os valores de resistência adesiva mais elevados em comparação aos demais tratamentos, mas sem apresentarem diferença estatística entre si, o que representou um aumento na resistência de união de 121% para o Clearfil SE e 109,2% para o Single Bond Universal em relação ao Grupo Controle. O uso do Ácido Poliacrílico (X?=9,94 ± 3,55) alcançou valores intermediários, correspondendo a um aumento de 20% na resistência adesiva em relação ao Grupo Controle. Esse tratamento se diferenciou estatisticamente dos maiores valores, porém não apresentou diferença frente ao Primer do Vitremer (X?=8,91 ± 2,97). O grupo controle (X?=8,26 ± 4,17) evidenciou os menores valores, se diferenciando estatisticamente dos sistemas adesivos e do Ácido Poliacrílico, mas com resultados que o equiparou ao tratamento com o Primer do Vitremer. Ao se analisar a interação entre cimento e tratamento, todos os cimentos de ionômero de vidro resinomodificados (CIVRMs) testados neste estudo apresentaram seus maiores resultados quando um dos sistemas adesivos foi utilizado como tratamento dentinário, independente de qual sistema adesivo. Com base nesses resultados, pôde-se concluir que os dois sistemas adesivos autocondicionantes foram capazes de melhorar significativamente a resistência adesiva dos CIVRMs. / This research aims to evaluate the influence of five dentin pretreatments on microshear bond strength of four resin-modified glass ionomer (RMGI). The experiment was performed in vitro, using 200 bovine incisors. From these, there were obtained 200 dentine fragments that were randomly distributed into 20 groups (n = 10) according to the variation factors comprising five dentin treatment (control group, i.e., no treatment; Polyacrylic Acid 20%; Clearfil SE Bond; Single Bond Universal and Vitremer Primer) and four glass ionomer cements (GC Fuji II LC® CAPSULE; GC Fuji LC LINING® (Paste Pak); Vitrebond® and Vitremer). After preparation of the samples and 24h storage at 37 °C, was performed microshear test in a universal testing machine (Instron 5942 - Canton, MA, USA) with speed of 1mm/min, followed by analysis of the pattern fractures in digital microscope. Statistical analysis of the 400 results was performed by ANOVA nonparametric test for two variation factors (cement and treatment) (p <0.05%) and the post-hoc Tukey (p <0.05%). The tests demonstrated there are statistical difference between treatments, cements and between the interaction of both (p <0.0001). The Clearfil SE (X?=18,26 ± 2,78) and SingleBond (X?=17,28 ± 2,49) promoted the highest bond strength values compared to the other treatments, but showing no statistical difference between them, which represented an increase in bond strength of 121% for Clearfil SE and 109.2% for Single Bond Universal compared to control group. The Polyacrylic Acid (X?=9,94 ± 3,55) has reached intermediate values, corresponding to a 20% increase in adhesive strength compared to control group. This treatment differed significantly from the higher values, but showed no difference compared to Primer Vitremer (X?=8,91 ± 2,97). The control group (X?=8,26 ± 4,17) showed the lowest values, statistically differing from the adhesives and polyacrylic acid, but with results that matched to the treatment with Vitremer Primer. When analyzing the interaction between cement and treatment, all cements tested in this study had higher results when one of the adhesive systems was used as dentin treatment, regardless of which adhesive system. Based on these results, it could be concluded that the two adhesive systems were able to significantly improve the adhesive strength of RMGIs.
|
59 |
Influência da irradiação com laser de Er, Cr:YSGG na resistência de união de sistemas adesivos em esmalte e dentina / Er,Cr:YSGG laser irradiation influence on enamel and dentin bond strength of adhesive systemsSergio Brossi Botta 04 June 2007 (has links)
Este trabalho teve o objetivo de avaliar a resistência adesiva de sistemas adesivos baseados no condicionamento prévio com ácido fosfórico (etch-and-rinse) e auto-condicionantes (de um e dois passos) ao substrato dental, submetido a diferentes condições de irradiação com laser de Er,Cr:YSGG. Amostras de esmalte e dentina foram obtidas do terço médio da face vestibular de 216 incisivos bovinos, divididos aleatoriamente em 18 grupos (n=12), de acordo com o substrato, (esmalte e dentina), sistema adesivo (etch-and-rinse, auto-condicionante de um passo e auto-condicionante de dois passos) e condições de irradiação (sem irradiação ? controle, irradiado com refrigeração ar-água e irradiado sem refrigeração ar-água). Em seguida foi realizada inclusão e polimento, sob refrigeração, com lixas de carbeto de silício de granulação decrescente 180, 320, 400 e 600 (por um minuto para padronização da camada de esfregaço). Para os grupos irradiados com laser de Er,Cr:YSGG (?=2,79 ?m, taxa de repetição de 20 Hz), com densidade de energia de 2,8 J/cm2, 12,5 mJ por pulso, potência média de 0,25W, com a ponta S75 de diâmetro de 750 ?m a 1 mm da superfície do substrato. A condição de refrigeração da irradiação foi realizada com 11 mL/min. Os corpos-de-prova foram confeccionados com a resina composta Filtek Z250, em forma de cone invertido para realização do teste de resistência adesiva. Após 24 h de armazenagem em água destilada a 37ºC, fez-se o ensaio de tração a 0,5 mm/min. Os dados foram comparados estatisticamente pelo método de ANOVA com significância de 5%. Os resultados obtidos mostraram que para o tecido esmalte foi observada diferença estatisticamente significante para os fatores adesivo e condições de irradiação empregadas, sem significância para a interação entre os fatores. A resistência de união do sistema adesivo auto-condicionante de dois passos e do sistema adesivo etch-and-rinse apresentam desempenho semelhante, sendo superiores ao sistema adesivo auto-condicionante de passo único. Ainda para esmalte, o efeito das condições de irradiação mostrou que os grupos sem irradiação com laser de Er,Cr:YSGG apresentaram maior resistência adesiva do que os grupos irradiados com refrigeração e sem refrigeração. Para o substrato dentina, houve diferença estatisticamente significante para os fatores de variação principais: sistemas adesivos, condição de irradiação com laser de Er,Cr:YSGG e para a interação adesivo X condição de irradiação. Quanto à comparação entre os sistemas adesivos testados na condição sem irradiação, os sistemas adesivos auto-condicionantes, de dois passos e o de um passo, não foram estatisticamente diferentes entre si, porém ambos forneceram resultados de resistência adesiva estatisticamente menores do que o sistema adesivo etch-and-rinse. Para as condições de irradiação com laser de Er,Cr:YSGG, com refrigeração e sem refrigeração, obteve-se valores de resistência adesiva maiores para o sistema auto-condicionante de dois passos do que para os demais sistemas. Deste modo, conclui-se que a irradiação com laser de Er,Cr:YSGG reduz a adesão ao esmalte independentemente do sistema adesivo utilizado e da condição de irradiação. Adicionalmente, observa-se que a irradiação de dentina com laser de Er,Cr:YSGG somente não altera a resistência adesiva do sistema auto-condicionante de dois passos, sendo deletéria aos demais adesivos testados. / The aim of this study was to assess the bond strength to dental substrate of adhesives based on previous etching with phosphoric acid (etch-and-rinse) and self-etching (one- and two-step) under different conditions of Er,Cr:YSGG laser irradiation. Enamel and dentin samples were obtained from the middle third of the buccal face of 216 bovine incisors, randomly divided in 18 groups (n=12), according to the substrate (enamel and dentin), adhesive system (etch-and-rinse, one-step self-etching and two-step self-etching) and irradiation condition (without irradiation ? control, irradiated with cooling, and irradiated without cooling). Next, the samples were included and polished, under cooling, with silicone carbide abrasive papers of decreasing grit #180, 320, 400 and 600 (for one minute to standardize the smear layer). For the irradiated groups with Er,Cr:YSGG laser, an energy density of 2.8 J/cm2, 12.5 mJ per pulse, mean power of 0.25W was selected. During laser irradiation, cooling was performed with 11 mL/min. Inverted cone-shaped test specimens were built-up with resin composite Filtek Z250, for performing the bond strength test. After 24 h storage in distilled water at 37ºC, the tensile test was performed at 0.5 mm/min. The results obtained show, for enamel, statistically significant difference for the factors adhesive and irradiation conditions used, without significance for the interaction among the factors. The bond strength of the 2-step self-etching and the etch-and-rinse adhesive system presented similar performance, being superior to that of one-step self-etching system. For enamel, the effect of the irradiation conditions showed that the groups without Er,Cr:YSGG laser irradiation presented higher bond strength than the groups irradiated with and without cooling. For the dentin substrate there was statistically significant difference for the main variation factors: adhesive systems, condition of Er,Cr:YSGG laser irradiation and for the interaction adhesive X irradiation condition. As regards the comparison among the adhesive systems tested under the condition without irradiation, the one-step and two-step self-etching adhesive systems did not differ statistically between them, but both provided statistically lower bond strength results than the etch-and-rinse adhesive system. For the condition of Er,Cr:YSGG laser irradiation with and without cooling, higher bond strength values were obtained for the two-step self-etching system than for the other systems. Therefore, it was concluded that Er,Cr:YSGG laser irradiation reduces the bond strength to enamel irrespective of the adhesive system used and the irradiation condition. Furthermore, it was observed that dentin irradiated with Er,Cr:YSGG laser did not alter the bond strength of the two-step adhesive system only, and it was deleterious to the other adhesives tested.
|
60 |
Estudo clínico randomizado e duplo-cego do Biosilicato sob restaurações de resina composta em dentes afetados por cárie / Double-blind, randomized clinical trial of Biosilicate under resin composite restorations in caries affected teethKaren Pintado Palomino 22 June 2017 (has links)
O presente estudo teve por objetivo avaliar o efeito de um biomaterial vitrocerâmico (Biosilicato®) no desempenho clínico de restaurações posteriores em resina composta. 92 cavidades Classe I e Classe II com lesão de cárie (no terço meio da dentina) foram selecionadas e distribuídas aleatoriamente em quatro grupos segundo o protocolo adesivo: 1- Biosilicato / sistema adesivo convencional de dois passos, 2- Controle / sistema adesivo convencional de dois passos, 3- Biosilicato / sistema adesivo autocondicionante de dois passos e 4- Controle / sistema adesivo autocondicionante de dois passos. Dois operadores realizaram os protocolos adesivos e restauraram as cavidades com uma resina composta nanohíbrida (IPS Empress, Ivoclar) usando a técnica incremental. Os participantes foram remarcados após uma semana, 6, 12 e 18 meses para avaliação clínica realizada por dois examinadores, cegados e calibrados de acordo com os critérios FDI. Os dados foram analisados com o teste não paramétrico de Kruskal-Wallis e o teste de Dunn de comparação múltipla, com nível de significância de 5%. Os resultados revelaram que não houve diferença estatisticamente significante (p > 0.05) entre os grupos experimentais e os respectivos controles em nenhuma avaliação, entretanto, houve diferença estatisticamente significativa (p < 0.05) entre os grupos controles (2 x 4) para o critério forma anatômica (1 semana) e adaptação marginal (18 meses). O grupo 2 foi estatisticamente diferente do grupo 3 (p < 0.05), para o critério fratura do material/retenção (18 meses) e adaptação marginal (1 semana), onde o grupo 2 apresentou melhor desempenho. O uso do Biosilicato no protocolo restaurador de dentina afetada por cárie não alterou o desempenho clinico de restaurações em resina composta no período de 18 meses de acompanhamento. A associação entre o sistema adesivo autocondicionante de dois passos e o Biosilicato gerou desempenho clínico inferior, comparado ao sistema adesivo convencional (controle), em termos de adaptação marginal e fratura do material/retenção. / The aim of this study was to evaluate the effect of a bioactive glass-ceramic (Biosilicate®) on clinical performance of posterior resin composite restorations. A total of 92 restorations in Class I and Class II cavities with carious lesion (medium third of dentin) were selected and assigned randomly into four groups according to the adhesive protocol used: 1- Biosilicate / Two-step etch and rinse system, 2- Control / Two-step etch and rinse system, 3- Biosilicate / Two-step self-etching system and 4- Control / Two-step self-etching system). Two operators carried out the adhesive protocols and restored the cavities with a nano-hybrid resin composite (IPS Empress, Ivoclar) using the incremental technique. Participants were recalled at one week, 6, 12 and 18 months for clinical evaluation performed by two blinded examiners and calibrated according to FDI criteria. Data were analyzed using Krusall-Wallis non-parametric test and multiple comparison Dunn test with a significance level of 5%. Results showed no statistical difference (p > 0.05) between the experimental groups and their respective controls; however, there were statistical difference between control groups (2 x 4) (p < 0.05) for anatomical form (1 week) and marginal adaptation (18 months). Group 2 was statistically different from Group 3 (p < 0.05), for fracture of material/retention (18 months) and marginal adaptation category (1 week), where Group 2 showed the better performance. The use of Biosilicate, in a restorative protocol for caries-affected dentin, did not alter the clinical performance of posterior resin composite restorations. The association between Biosilicate and two-step self-etching adhesive system showed an inferior clinical performance, compared to the conventional adhesive system (control), in terms of marginal adaptation and fracture of material/retention.
|
Page generated in 0.0557 seconds