• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 109
  • 1
  • Tagged with
  • 113
  • 82
  • 22
  • 22
  • 22
  • 20
  • 20
  • 20
  • 17
  • 16
  • 16
  • 16
  • 15
  • 14
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Estratégia operacional de sistema formado por reator não compartimentado com setores com aeração/sem aeração precedido por reator anaeróbio / Operational strategies of system consisting of non-compartmentalized aerated reactor with sectors with aeration/without aeration preceded by an anaerobic reactor

Aurélia de Oliveira Almeida 10 October 2014 (has links)
A opção por sistemas biológicos prevalece para o tratamento do esgoto sanitário. Nas décadas recentes, sistemas que possuem regiões e/ou zonas anaeróbia, anóxica e aeróbia têm-se mostrado como alternativas atraentes para remoção simultânea de matéria orgânica, nitrogênio e fósforo. No entanto, os aspectos operacionais ainda merecem ser objeto de estudo para alcançar desempenho otimizado. Nesse cenário, com intuito de comparar alternativas para a operação das unidades de tratamento de esgoto, o presente trabalho propôs-se a estudar estratégias operacionais associadas ao monitoramento, em tempo real, sem adição de fonte externa de carbono, para um reator aerado não compartimentado com crescimento suspenso e fluxo contínuo precedido de reator anaeróbio. O sistema experimental, em escala de bancada, era constituído de um reator anaeróbio, com volume útil de 43,54 L, e reator aerado, com volume útil de 68,07 L; sendo que este era formado por sete setores, em série, sem separação física. O estudo foi dividido em duas etapas: I - estudo da variação dos volumes da região aerada e da não aerada; II - estudo da aeração intermitente com ciclo de aeração/agitação pré-fixado e controlado em tempo real por sistema informatizado. Em todas as Etapas do estudo ocorreu elevada remoção de DBO e conversão de NTK para nitrato, contudo não se conseguiu obter desnitrificação em nível desejado. O uso de reatores com setores sequenciais sem divisão física (Etapa I) dificultou a obtenção de regiões distintas predominantemente anóxica e aeróbia, comprometendo a remoção de nitrogênio (principalmente a desnitrificação). A maior eficiência média de remoção de nitrogênio alcançada no reator aerado foi de 35,6% (Etapa II), quando o reator era operado com aeração intermitente sendo o ciclo de aeração/agitação controlado em tempo real. A estratégia de operação com aeração intermitente, estudada na Etapa II, favoreceu a remoção de nitrogênio. A aeração intermitente demonstrou ser uma opção promissora comparada à aeração contínua em setores específicos do reator. O controle automatizado e informatizado em tempo real dos ciclos de aeração/agitação pode ser aplicado no aperfeiçoamento da operação dos sistemas de tratamento de esgoto sanitário. / The option of biological systems prevails for the treatment of sewage waste and in recent decades, systems that have anaerobic, anoxic, aerobic regions and / or zones have proven attractive for simultaneous removal of organic matter, nitrogen and phosphorus. However, the operational aspects still deserve to be studied in order to achieve the optimized performance of these systems. In this scenario, in order to compare alternatives for the operation of sewage treatment plants, the present work aimed to study operational strategies associated with monitoring, in real time, without the addition of external carbon source, for a non-compartmentalized aerated reactor with growth suspended and continuous flow preceded by anaerobic reactor. The experimental system in bench scale consisted of an anaerobic reactor, with a volume of 43.54 L and an aerated reactor, with a volume of 68.07 L; consisting of seven sectors, in series, without physical separation. The study was divided into two stages: I - study of the variation of the volume of the aerated and non-aerated regions; II - study of intermittent aeration with cycle of aeration/agitation controlled by a pre-fixed time interval; and controlled in real time by a computerized system. In all Stages of the study high BOD removal and conversion of TKN to nitrate occurred, but were unable to obtain denitrification at desired level. The use of reactors with sequential sectors without physical division (Stage I) made it difficult to obtain predominantly distinct anoxic and aerobic regions, compromising the removal of nitrogen (mainly the denitrification). The highest average removal efficiency of nitrogen attained in aerated reactor was 35.6% when the reactor was operated with intermittent aeration with aeration cycle controlled in real time. The operation strategy with intermittent aeration, studied in Stage II, favored the removal of nitrogen. The intermittent aeration proved to be a promising option compared to continuous aeration in specific sectors of the reactor. The automated and computerized control in real-time of the aeration / agitation cycles can be applied in improving the operation of sewage waste treatment systems.
112

Impacto de duas estratégias de titulação da PEEP em modelo suíno de síndrome do desconforto respiratório agudo: guiada por pressão esofágica versus guiada por tomografia de impedância elétrica / Impact of two PEEP titration strategies in a swine model of acute respiratory distress syndrome: guided by esophageal pressure versus guided by electrical impedance tomography

Roldan Mori, Audie Rollin 05 July 2017 (has links)
INTRODUÇÃO: O uso de níveis elevados da pressão expiratória final positiva (PEEP) na Síndrome do desconforto respiratório agudo (SDRA), visando reduzir a quantidade de pulmão colapsado, tornando a ventilação mais homogênea, tem sido apontado por estudos clínicos randomizados e metaanálises como uma estratégia eficaz na melhora de alguns desfechos clínicos. Atualmente, não existe um método ideal para ajuste da PEEP na SDRA. Dois métodos distinguem-se pela racionalidade fisiológica e possibilidade de serem usados na prática clínica usual: ajuste da PEEP guiado por Pressão Esofágica (Pes) e ajuste da PEEP guiado por Tomografia de Impedância Elétrica (TIE). Os objetivos do estudo foram: (1) Avaliar, através de tomografia computadorizada de tórax (raios X), qual estratégia induz uma melhor aeração pulmonar: maior recrutamento pulmonar e menor hiperdistensão; (2) Avaliar as alterações da distribuição regional da ventilação, do volume pulmonar e da complacência regional medidos pela tomografia de impedância elétrica; (3) Avaliar as alterações na mecânica pulmonar e nas trocas gasosas produzidas por ambas as estratégias de titulação da PEEP. MÉTODOS: Dez porcos foram submetidos a um modelo de SDRA grave: depleção de surfactante mais lesão pulmonar induzida pelo ventilador. Após uma manobra de recrutamento (MR), duas estratégias de titulação da PEEP foram testadas em uma sequência aleatória: 1) Utilizando a tomografia por impedância elétrica para calcular a menor PEEP que mantem um colapso pulmonar menor de 1%; 2) Utilizando a pressão esofágica para calcular a PEEP necessária para atingir uma pressão transpulmonar final expiratória (PLexp) entre 5-6 cmH2O. Em seguida, os animais foram ventilados durante 1 hora com a PEEP ótima estimada por cada método. Foram registrados parâmetros fisiológicos e de tomografia computadorizada (TC) antes da MR (tempo basal) e após ventilação com a PEEP ótima (15 min e 60 min). RESULTADOS: Aos 60 min, ambas as estratégias reduziram o colapso pulmonar, mas com efeitos significativamente maiores (P < 0,05) no grupo TIE: tecido não-aerado (20,3 ± 11,8% vs. 38,6 ± 13,1%, TIE vs. Pes respectivamente), recrutamento cíclico (4,8 ± 3,7% vs. 8,7 ± 2,7%), PaO2/FIO2 (289 ± 78 vs. 209 ± 92 mmHg), pressão de distensão (14,5 ± 2,3 vs. 16,1 ± 2,3 cmH2O), e pressão de distensão transpulmonar (11,9 ± 1,7 vs. 13,6 ± 1,8 cmH2O). Apesar da escolha de uma maior PEEP ótima no grupo TIE, a pressão platô (33,2 ± 3,7 vs. 31,5 ± 3,1 cmH2O), a pressão transpulmonar inspiratória final (20,0 ± 2,8 vs. 19,2 ± 1,7 cm H2O) e a complacência das áreas não dependentes do pulmão medidas pela TIE (0,07 ± 0,04 vs 0,06 ± 0,05 unidades arbitrárias/cmH2O) ou TC (1,52 ± 0,90 vs. 1,41 ± 0,98 mL/cmH2O) variaram de forma semelhante nos dois grupos (P > 0,05). O tecido hiperaerado e a hipedistensão cíclica foram baixos em ambos os grupos. CONCLUSÕES: Neste modelo animal de SDRA grave o ajuste da PEEP guiado por TIE produz um maior recrutamento pulmonar e sinais fisiológicas de melhor proteção pulmonar quando comparado com o ajuste da PEEP guiado por Pes / INTRODUCTION: The use of higher levels of positive end-expiratory pressure (PEEP) in the acute respiratory distress syndrome (ARDS), aimed at reducing the amount of lung collapse, making the ventilation more homogeneous, has been pointed out by randomized clinical trials and meta-analysis as an effective strategy to improve some clinical outcomes. Currently, there is no ideal method for adjustment PEEP in ARDS. Two methods are distinguished by their physiological rationality and the possibility of being used in the clinical practice: PEEP titration guided by Esophageal Pressure (Pes) and PEEP titration guided by Electrical Impedance Tomography (EIT). The objectives of the study were: 1) To evaluate through computed tomography of thorax (X-ray), which strategy induces better pulmonary aeration: greater lung recruitment and less hyperdistension; (2) To evaluate changes in the regional distribution of ventilation, pulmonary volume and regional compliance, measured by electrical impedance tomography; (3) To assess changes in lung mechanics and gas exchange produced by both PEEP titration strategies. METHODS: Ten pigs were submitted to a two-hit model of severe ARDS: Surfactant depletion plus ventilator-induced lung injury. After a recruitment maneuver (RM), two strategies of PEEP titration were tested in a randomized sequence: 1) Using electric impedance tomography to calculate the lowest PEEP keeping recruitable-lungcollapse < 1%; 2) Using esophageal pressure to calculate the PEEP needed to achieve an end-expiratory transpulmonary pressure between 5-6 cmH2O. Then, animals were ventilated for 1 hour with the optimum-PEEP estimated by each method. Physiological and computed tomography (CT) parameters were recorded before RM (baseline) and after ventilation at optimum-PEEP (15 min and 60 min). RESULTS: At 60 min, both strategies reduced lung collapse but with significantly (P < 0.05) greater effects in EIT-group: nonaerated tissue (20.3 ± 11.8% vs 38.6 ± 13.1%, EIT vs. Pes, respectively), tidal recruitment (4.8 ± 3.7% vs 8.7 ± 2.7%), PaO2/FIO2 (289 ± 78 vs 209 ± 92 mmHg), driving-pressure (14.5 ± 2.3 vs 16.1 ± 2.3 cmH2O) and transpulmonary driving-pressure (11.9 ± 1.7 vs 13.6 ± 1.8 cmH2O). Despite the choice for a higher optimum-PEEP in the EIT-group; plateau pressure (33.2 ± 3.7 vs 31.5 ± 3.1 cmH2O), end-inspiratory transpulmonary pressure (20.0 ± 2.8 vs 19.2 ± 1.7 cmH2O) and compliance of non-dependent areas measured by EIT (0.07 ± 0.04 vs 0.06 ± 0.05 arbitrary units/cmH2O) or CT (1.52 ± 0.90 vs 1.41 ± 0.98 mL/cmH2O) varied similarly in both groups (P > 0.05). Hyperaerated tissue and tidal hyperinflation were very low in both groups. CONCLUSION: In this model, the choice of PEEP guided by EIT leads to higher lung recruitment and physiological signals of a better lung protection, when compared to the strategy guided by Pes
113

Impacto de duas estratégias de titulação da PEEP em modelo suíno de síndrome do desconforto respiratório agudo: guiada por pressão esofágica versus guiada por tomografia de impedância elétrica / Impact of two PEEP titration strategies in a swine model of acute respiratory distress syndrome: guided by esophageal pressure versus guided by electrical impedance tomography

Audie Rollin Roldan Mori 05 July 2017 (has links)
INTRODUÇÃO: O uso de níveis elevados da pressão expiratória final positiva (PEEP) na Síndrome do desconforto respiratório agudo (SDRA), visando reduzir a quantidade de pulmão colapsado, tornando a ventilação mais homogênea, tem sido apontado por estudos clínicos randomizados e metaanálises como uma estratégia eficaz na melhora de alguns desfechos clínicos. Atualmente, não existe um método ideal para ajuste da PEEP na SDRA. Dois métodos distinguem-se pela racionalidade fisiológica e possibilidade de serem usados na prática clínica usual: ajuste da PEEP guiado por Pressão Esofágica (Pes) e ajuste da PEEP guiado por Tomografia de Impedância Elétrica (TIE). Os objetivos do estudo foram: (1) Avaliar, através de tomografia computadorizada de tórax (raios X), qual estratégia induz uma melhor aeração pulmonar: maior recrutamento pulmonar e menor hiperdistensão; (2) Avaliar as alterações da distribuição regional da ventilação, do volume pulmonar e da complacência regional medidos pela tomografia de impedância elétrica; (3) Avaliar as alterações na mecânica pulmonar e nas trocas gasosas produzidas por ambas as estratégias de titulação da PEEP. MÉTODOS: Dez porcos foram submetidos a um modelo de SDRA grave: depleção de surfactante mais lesão pulmonar induzida pelo ventilador. Após uma manobra de recrutamento (MR), duas estratégias de titulação da PEEP foram testadas em uma sequência aleatória: 1) Utilizando a tomografia por impedância elétrica para calcular a menor PEEP que mantem um colapso pulmonar menor de 1%; 2) Utilizando a pressão esofágica para calcular a PEEP necessária para atingir uma pressão transpulmonar final expiratória (PLexp) entre 5-6 cmH2O. Em seguida, os animais foram ventilados durante 1 hora com a PEEP ótima estimada por cada método. Foram registrados parâmetros fisiológicos e de tomografia computadorizada (TC) antes da MR (tempo basal) e após ventilação com a PEEP ótima (15 min e 60 min). RESULTADOS: Aos 60 min, ambas as estratégias reduziram o colapso pulmonar, mas com efeitos significativamente maiores (P < 0,05) no grupo TIE: tecido não-aerado (20,3 ± 11,8% vs. 38,6 ± 13,1%, TIE vs. Pes respectivamente), recrutamento cíclico (4,8 ± 3,7% vs. 8,7 ± 2,7%), PaO2/FIO2 (289 ± 78 vs. 209 ± 92 mmHg), pressão de distensão (14,5 ± 2,3 vs. 16,1 ± 2,3 cmH2O), e pressão de distensão transpulmonar (11,9 ± 1,7 vs. 13,6 ± 1,8 cmH2O). Apesar da escolha de uma maior PEEP ótima no grupo TIE, a pressão platô (33,2 ± 3,7 vs. 31,5 ± 3,1 cmH2O), a pressão transpulmonar inspiratória final (20,0 ± 2,8 vs. 19,2 ± 1,7 cm H2O) e a complacência das áreas não dependentes do pulmão medidas pela TIE (0,07 ± 0,04 vs 0,06 ± 0,05 unidades arbitrárias/cmH2O) ou TC (1,52 ± 0,90 vs. 1,41 ± 0,98 mL/cmH2O) variaram de forma semelhante nos dois grupos (P > 0,05). O tecido hiperaerado e a hipedistensão cíclica foram baixos em ambos os grupos. CONCLUSÕES: Neste modelo animal de SDRA grave o ajuste da PEEP guiado por TIE produz um maior recrutamento pulmonar e sinais fisiológicas de melhor proteção pulmonar quando comparado com o ajuste da PEEP guiado por Pes / INTRODUCTION: The use of higher levels of positive end-expiratory pressure (PEEP) in the acute respiratory distress syndrome (ARDS), aimed at reducing the amount of lung collapse, making the ventilation more homogeneous, has been pointed out by randomized clinical trials and meta-analysis as an effective strategy to improve some clinical outcomes. Currently, there is no ideal method for adjustment PEEP in ARDS. Two methods are distinguished by their physiological rationality and the possibility of being used in the clinical practice: PEEP titration guided by Esophageal Pressure (Pes) and PEEP titration guided by Electrical Impedance Tomography (EIT). The objectives of the study were: 1) To evaluate through computed tomography of thorax (X-ray), which strategy induces better pulmonary aeration: greater lung recruitment and less hyperdistension; (2) To evaluate changes in the regional distribution of ventilation, pulmonary volume and regional compliance, measured by electrical impedance tomography; (3) To assess changes in lung mechanics and gas exchange produced by both PEEP titration strategies. METHODS: Ten pigs were submitted to a two-hit model of severe ARDS: Surfactant depletion plus ventilator-induced lung injury. After a recruitment maneuver (RM), two strategies of PEEP titration were tested in a randomized sequence: 1) Using electric impedance tomography to calculate the lowest PEEP keeping recruitable-lungcollapse < 1%; 2) Using esophageal pressure to calculate the PEEP needed to achieve an end-expiratory transpulmonary pressure between 5-6 cmH2O. Then, animals were ventilated for 1 hour with the optimum-PEEP estimated by each method. Physiological and computed tomography (CT) parameters were recorded before RM (baseline) and after ventilation at optimum-PEEP (15 min and 60 min). RESULTS: At 60 min, both strategies reduced lung collapse but with significantly (P < 0.05) greater effects in EIT-group: nonaerated tissue (20.3 ± 11.8% vs 38.6 ± 13.1%, EIT vs. Pes, respectively), tidal recruitment (4.8 ± 3.7% vs 8.7 ± 2.7%), PaO2/FIO2 (289 ± 78 vs 209 ± 92 mmHg), driving-pressure (14.5 ± 2.3 vs 16.1 ± 2.3 cmH2O) and transpulmonary driving-pressure (11.9 ± 1.7 vs 13.6 ± 1.8 cmH2O). Despite the choice for a higher optimum-PEEP in the EIT-group; plateau pressure (33.2 ± 3.7 vs 31.5 ± 3.1 cmH2O), end-inspiratory transpulmonary pressure (20.0 ± 2.8 vs 19.2 ± 1.7 cmH2O) and compliance of non-dependent areas measured by EIT (0.07 ± 0.04 vs 0.06 ± 0.05 arbitrary units/cmH2O) or CT (1.52 ± 0.90 vs 1.41 ± 0.98 mL/cmH2O) varied similarly in both groups (P > 0.05). Hyperaerated tissue and tidal hyperinflation were very low in both groups. CONCLUSION: In this model, the choice of PEEP guided by EIT leads to higher lung recruitment and physiological signals of a better lung protection, when compared to the strategy guided by Pes

Page generated in 0.051 seconds