• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Removal of pharmaceutical residues from wastewater / Avlägsnande av läkemedelsrester från avloppsvatten

Goralski, Alma January 2019 (has links)
Today, pharmaceutical residues are widely found in nature as a cause of the extensive use of human and veterinary medicine. The pharmaceutical residues have shown to have a damaging impact on flora and fauna. Wastewater Treatment Plants (WWTPs), today, are not designed for pharmaceutical removal, which calls for new methods and the implementation of these to avoid increased concentrations of pharmaceutical residues in nature. This thesis addresses three main areas. Firstly, a pre-study regarding the prevalence of pharmaceutical residues at different parts of a WWTP and in the nearby river, secondly, an evaluation of removal of pharmaceutical residues using ozone and, thirdly, the construction of a pilot plant scale Activated Carbon (AC) unit and an evaluation of its capacity for pharmaceutical and ozone removal. This work was done in order to verify the quality of a future full-scale unit including the advanced techniques ozone and AC that will be implemented at a WWTP for pharmaceutical removal. The pre-study shows that the total concentration of the Active Pharmaceutical Ingredients (APIs) was largest at the inlet (93.8 mg/L) and decreased throughout the process steps to be the lowest at the outlet (5.6 mg/L). Paracetamol was found in the highest concentration (86.5 mg/L) at the inlet but could not be detected in the outlet. In the recipient none of the APIs could be found. However, caffeine was detected in the recipient. The pilot plant studies were performed in a batch process, one at high ozone generation and one at low ozone generation. The pilot test at high ozone generation showed that all of the measured APIs were below their Limit of Quantification (LOQ) after 2 minutes. The pilot test at low ozone generation showed a total API-removal of 44% after 7 minutes, 78% after 13 minutes, 97% after 20 minutes and more than 99% after 60 minutes. All of the APIs were below their LOQ after 180 min. The AC-filter construction mirrored the conditions within a full-scale unit as closely as possible and was scaled by the superficial velocity. The AC-filter showed an ozone removal of approximately 99% and removed all pharmaceutical residues apart from Ranitidine which was decreased by 76%. / Idag återfinns läkemedelsrester i stor utsträckning i naturen, vilket är ett resultat av den omfattande användningen av human- och veterinärmediciner. Läkemedelsresterna har visat sig ha en skadlig effekt på flora och fauna. Dagens avloppsreningsverk är inte byggda för att rena vattnet från läkemedelsrester, vilket kräver att nya metoder utvecklas och implementeras för att förebygga spridning av läkemedel. Denna avhandling redogör för tre huvudområden, inledningsvis en förstudie om förekomsten av läkemedelsrester i olika delar av ett vattenreningsverk samt i en närliggande å. Därefter en studie av ozons förmåga att eliminera läkemedelsrester och slutligen konstruktion av ett aktivt kolfilter och en utvärdering av dess förmåga att ta bort läkemedel. Detta gjordes med syftet att verifiera kvalitén hos en fullskalig anläggning som kommer att installeras på ett vattenreningsverket där ozon och aktivt kol kommer användas för borttagning av läkemedelsrester. Förstudien visar att totalkoncentrationen av de aktiva läkemedelssubstanserna (API:er) var som störst vid inloppet av reningsverket (93.8 μg/L) och koncentrationen minskade genom de olika processtegen och var som lägst i utloppet (5.6 μg/L). Paracetamol återfanns i den högsta koncentrationen i inloppet (86.5 μg/L), men kunde inte detekteras i utloppet. Ingen av API:erna återfanns i recipienten, men däremot detekterades koffein. Pilotanläggningsstudierna genomfördes i en batch och genomfördes med högozongenerering och med låg ozongenerering. Studien med hög ozongenerering visade att alla läkemedelsrester var under analysmetodens detektionsgräns efter 2 minuter. Pilotstudien med låg ozonegenerering visade att den totala läkemedelsborttagningen var 44 % efter 7 minuter, 78 % efter 13 minuter, 97 % efter 20 minuter och mer än 99 % efter 60 minuter. Alla läkemedelsrester var under analysmetodens detektionsgräns efter 180 min. Kolfiltret konstruerades för att efterlikna det fullskaliga filtret så mycket som möjligt och skalades således efter den hypotetiska tomma bäddhastigheten. Kolfiltret tog bort cirka 99 % av ozonet och alla läkemedelsrester utom Ranitidin som reducerades med 76 %.
2

Removal efficiency of multiple per- and polyfluoroalkyl substances (PFAS) in groundwater at a landfill using granular activated carbon (GAC) and anion exchange (AIX) column tests

Ferndahl, Sara January 2024 (has links)
Per- and polyfluorinated substances (PFAS) are used in many areas of application due to their many beneficial properties such as heat resistance. insulator and water- and oil repellent. PFAS containing products can often be found in landfills and their leachate. This study compares the two common treatment techniques granulated activated carbon (GAC) and anion exchange (AIX) for treating groundwater at a landfill site. The removal efficiencies of the PFAS found at the site were determined for both methods as well as the cost of treatment for removal efficiencies at 99, 95, 90, 85, 80 and 50 % for one cubic metre of groundwater. Twenty different PFAS were found and the removal efficiency of ∑PFAS ranged between 4 – 90 % for two stage GAC and 30 – 100% for AIX. Within the groups perfluoroalkyl carboxylic acid (PFCA) and perfluorosulfonic acid (PFSA), both methods were most efficient in removing long chains. PFSA generally had a higher removal efficiency than PFCA. The cost of removing PFAS was related to the removal efficiency. Since AIX had a higher removal efficiency the cost became lower, despite the filter media costing nearly seven times more than GAC’s. The costs of removing PFCA and PFSA were 3.1 – 32 and 2.3 – 6.5 euros/m3 groundwater for removal of 50 – 99% using AIX. For GAC, the cost could not be calculated for 99 % removal since the removal efficiencies were too low for the Lin and Huang adsorption model to work. For 50 – 95% removal the costs for PFCA and PFSA were 2.9 – 23.1 and 2.8 – 6.9 euros/m3 groundwater.
3

Resource monitoring in a Network Embedded Cloud : An extension to OSPF-TE

Roozbeh, Amir January 2013 (has links)
The notions of "network embedded cloud", also known as a "network enabled cloud" or a "carrier cloud", is an emerging technology trend aiming to integrate network services while exploiting the on-demand nature of the cloud paradigm. A network embedded cloud is a distributed cloud environment where data centers are distributed at the edge of the operator's network. Distributing data centers or computing resources across the network introduces topological and geographical locality dependency. In the case of a network enabled cloud, in addition to the information regarding available processing, memory, and storage capacity, resource management requires information regarding the network's topology and available bandwidth on the links connecting the different nodes of the distributed cloud. This thesis project designed, implemented, and evaluated the use of open shortest path first with traffic engineering (OSPF-TE) for propagating the resource status in a network enabled cloud. The information carried over OSPF-TE are used for network-aware scheduling of virtual machines. In particular, OSPF-TE was extended to convey virtualization and processing related information to all the nodes in the network enabled cloud. Modeling, emulation, and analysis shows the proposed solution can provide the required data to a cloud management system by sending a data center's resources information in the form of new opaque link-state advertisement with a minimum interval of 5 seconds. In this case, each embedded data centers injects a maximum 38.4 bytes per second of additional traffic in to the network.<p> / Ett "network embedded cloud", även känt som ett "network enabled cloud" eller ett "carrier cloud", är en ny teknik trend som syftar till att tillhandahålla nätverkstjänster medan on-demand egenskapen av moln-paradigmet utnyttjas.  Traditionella telekommunikationsapplikationer bygger ofta på en distributed service model och kan använda ett "network enabled cloud" som dess exekverande plattform. Dock kommer sådana inbäddade servrar av naturliga skäl vara geografiskt utspridda, varför de är beroende av topologisk och geografisk lokalisering. Detta ändrar på resurshanteringsproblemet jämfört med resurshantering i datacentrum. I de fall med ett network enabled cloud, utöver informationen om tillgängliga CPU, RAM och lagring, behöver resursfördelningsfunktionen information om nätverkets topologi och tillgänglig bandbredd på länkarna som förbinder de olika noderna i det distribuerade molnet. Detta examensarbete har utformat, tillämpat och utvärderat ett experiment-orienterad undersökning av användningen av open shortest path first med traffich engineering (OSPF-TE) för resurshantering i det network enabled cloud. I synnerhet utvidgades OSPF-TE till att förmedla virtualisering och behandla relaterad information till alla noder i nätverket. Detta examensarbete utvärderar genomförbarheten och lämpligheten av denna metod, dess flexibilitet och prestanda. Analysen visade att den föreslagna lösningen kan förse nödvändiga uppgifter till cloud management system genom att skicka ett datacenters resursinformation i form av ny opaque LSA (kallat Cloud LSA) med ett minimumintervall av 5 sekunder och maximal nätverksbelastning av 38,4 byte per sekund per inbäddade data center.

Page generated in 0.072 seconds