• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Quantitative rastertunnelmikroskopische Untersuchungen akustischer Oberflächenwellenfelder auf der Nanometerskala

Voigt, Peter 19 June 2002 (has links)
Diese Arbeit befaßt sich mit der SAW-STM-Methode, einer Abwandlung der Rastertunnelmikroskopie (engl. scanning tunneling microscopy) zur hochauflösenden Abbildung akustischer Oberflächenwellen (engl. surface acoustic wave). Das Meßprinzip des SAW-STM beruht auf der Modulation des Tunnelabstandes und der hieraus resultierenden Modulation des Tunnelstroms durch die oszillatorische Bewegung der Probenoberfläche. Zur einfacheren Signaldetektion wird ein Heterodyn-Verfahren verwendet, das über eine zusätzliche Modulation der Tunnelspannung das SAW-STM Signal in den kHz-Frequenzbereich verschiebt. Dieses trägt die komplette Information über die Amplitude und die Phase der Tunnelabstandsmodulation. Im Rahmen dieser Arbeit wird die Abhängigkeit des SAW-STM Signals von den experimentellen Paramtern und von der Topographie der Probe theoretisch beschrieben und experimentell untersucht. Dies führt zu einer kalibrierten Vermessung der oszillatorischen Bewegungsbahn der SAW-tragenden Probenoberfläche. Das untersuchte Materialsystem ist ein 40 nm dicker Goldfilm auf einem LiNbO3-Substrat im Y-Schnitt, das eine Welle vom Rayleigh-Typ in Z-Richtung trägt. Indem ein SAW-STM entwickelt wird, das im Ultrahochvakuum (UHV) arbeitet, wird die SAW-STM Methode hinsichtlich des Spektrums untersuchbarer reaktiver Materialien und hinsichtlich der Signalstabilität. Es wird der Umbau eines kommerziellen Rastertunnelmikroskops zum SAW-STM beschrieben. Zu diesem Zweck wird eine Probenhalterung konstruiert, die den Transfer der Probe zwischen der Bedampfungseinrichtung und dem STM ohne Belüftung der Kammer erlaubt. Gleichzeitig stellt sie automatisch die fünf notwendigen elektrischen Kontakte zum Probenchip her, wenn die Probenhalterung in das STM gesetzt wird. Weiterhin werden die Konstruktion eines UHV-tauglichen Sytems von Hochfrequenz-Signalleitungen und der Bedampfungseinrichtung zur in-situ Probenpräparation beschrieben. Mit diesem UHV-SAW-STM können SAWs einer Amplitude im Bereich von 0.001 Å bis 1 Å angeregt und detektiert werden. Die maximale Frequenz, die eine im UHV-SAW-STM nachweisbare SAW haben kann, beträgt mindestens 360 MHz. Weiterhin wird das in LabVIEW geschriebenen Softwarepacket zur Auswertung der SAW-STM-Daten vorgestellt. Um die SAW-STM-Methode auf ein sicheres Fundament zu stellen, wurde erstmals systematisch die Abhängigkeit des SAW-STM-Signals von den Meßparametern experimentell untersucht. Die im Rahmen dieser Arbeit entwickelte Theorie des SAW-STM-Signals beschreibt die experimenell gefundenen Abhängigkeiten hinreichend gut. Zentraler Punkt dieser Theorie ist dabei die Berücksichtigung der Abstandsregelung des STM, die im Constant-Current-Modus die Spitzenposition so regelt, daß der mittlere Tunnelstrom konstant ist. Der Vergleich der gemessenen und der theoretischen Abhängigkeit der Signalamplitude von der Amplitude der Modulation des Tunnelabstandes ermöglicht dabei die kalibrierte Messung der Amplitude der vertikale Auslenkung der Rayleighwelle. Scans der SAW-STM-Methode liefern Bilder der Topographie sowie der Amplitude und der Phase des SAW-STM-Signals. Mit der Theorie des SAW-STM-Signal der korrugierten Probenoberfläche werden aus der gemessenen Topographie simulierte Amplituden- und Phasebilder erstellt und mit den gemessenen Bildern verglichen. Während die Übereinstimmung mit den gemessenen Amplitudenbildern nur qualitativer Art ist, erlaubt der quantitative Vergleich zwischen simulierten und gemessenen Phasenbildern die Bestimmung der Exzentrizität der Oszillationsellipse. Zusammen mit der oben erläuterten Messung der vertikalen Auslenkungsamplitude ist somit in dieser Arbeit die Oszillationsellipse der Rayleighwelle vollständig ausgemessen. / This thesis deals with the SAW-STM method, which is a technique based on scanning tunneling microscopy (STM) for the high-resolution mapping of surface acoustic waves (SAW). The measurement principle of the SAW-STM utilizes the modulation of the tunneling distance and the resulting modulation of the tunneling current due to the mechanic oscillation of the sample surface. To facilitate signal detection a heterodyn technique is employed which shifts the measured signal into the kHz-range by adding modulation to the tunneling voltage. The signal contains the entire information about the amplitude and the phase of the SAW-induced tunneling distance modulation. Experiments are presented to investigate the dependence of the signal amplitude on the experimental parameters and on the sample topography. This data is compared to a theory developed to describe the SAW-STM signal, leading to a calibrated measurement of the trajectory of the sample surface which carries the wave. The sample we investigated was a 40 nm gold film deposited on a LiNbO3 substrate in the Y-cut, deformed by a Rayleigh-type wave in the z-direction. To increase signal stability and to extend the range of reactive sample materials we constructed a SAW-STM operating in the ultra-high-vacuum (UHV). In this thesis the conversion of a commercial STM to a SAW-STM is described. A sample holder is constructed, which allows the transfer of the sample between the evaporation stage and the STM without venting the UHV chamber. It provides a contact spring mechanism for the automatical electric contactation of the sample chip, when the sample holder is inserted into the STM. Moreover, we installed a UHV-compatible wiring system for SAW-excitation and for signal detecting and an evaporation stage for in-situ sample preparation. We demonstrate that the UHV-SAW-STM is capable of exiting and detecting surface acoustic waves with an amplitude in the range 0.001 Å to 1 Å. The maximal frequency of SAW which can be studied with the UHV-SAW-STM is found to be at least 360 MHz. For the analysis of SAW-STM data a LabVIEW software package was implemented. To put the SAW-STM technique on a strong basis, we systematically studies the dependence of the SAW-STM signal on the various measurement parameters. The theory of the SAW-STM signal developed in this work is in good agreement with this experimental data. In this theory, we take into account that the STM is operated in the constant-current mode, i.e. the tip position is controlled to keep the average tunneling current constant. The comparison of the measured and the simulated dependence of the signal amplitude on the amplitude of the tunneling distance modulation allows the calibrated measurement of the vertical displacement amplitude of the Rayleigh wave. SAW-STM scans yield images of the topography and of the amplitude and the phase of the SAW-STM signal. Employing the theory of the SAW-STM signal on the corrugated surface, we simulated amplitude and phase imaged based on the measured topography. The agreement between simulated and measured amplitude images is only qualitative. In contrast, the comparison of simulated and measured phase images allows the determination of the excentricity of the oscillation ellipse. Having determined this excentricity and the vertical displacement amplitude of the Rayleigh wave, we have gaind complete knowledge about the geometry of the Rayleigh wave oscillation ellipse.
2

Migrationsbeständigkeit von Al- und Cu-Metallisierungen in SAW-Bauelementen / Resistance against migration in Al and Cu metallizations for SAW devices

Pekarcikova, Marcela 20 December 2005 (has links) (PDF)
Im Rahmen dieser Arbeit wurde die Akustomigrationsresistenz von in Kupfertechnologie hergestellten SAW-Strukturen charakterisiert und diese mit dem Schädigungsverhalten von Al-basierten SAW-Strukturen unter gleichen Belastungsbedingungen verglichen. Dies wurde durch die Anwendung einer speziellen Power-SAW-Teststruktur ermöglicht. Das Schädigungsniveau wurde hierbei über die irreversible Verschiebung der Peakfrequenz bzw. durch Änderungen im elektrischen Widerstand sowie durch mikroskopische Untersuchung der Mikrostruktur beurteilt. Die durchgeführten SAW-Belastungsexperimente mit HF-Leistungen bis zu 4,5 W zeigten, dass das entwickelte Ta-Si-N/Cu/Ta-Si-N-System im Vergleich zur Al/Ti-Metallisierung eine Akustomigrationsresistenz besitzt, die um mehr als drei Größenordnungen höher ist als jene der Al/Ti-Metallisierung. Hohe SAW-Belastungen verursachten sowohl im Al- als auch im Cu-Testwandler Hügel- und Lochbildung. Während die Hügel in der Al/Ti-Metallisierung senkrecht zur Oberfläche bis zu einer Höhe von 1 µm und die Löcher bis hinab an die Ti-Schicht wuchsen, bildeten sich in den extrem belasteten Cu-basierten Wandlern nur flache Hügel und schmale Löcher aus, welche noch mit der Deckschicht vollständig bedeckt waren. Anhand von REM/EBSD, TEM sowie FIB-Untersuchungen konnte ein relevanter Zusammenhang zwischen der Mikrostruktur und dem Schädigungsverhalten aufgezeigt werden.
3

Migrationsbeständigkeit von Al- und Cu-Metallisierungen in SAW-Bauelementen

Pekarcikova, Marcela 05 October 2005 (has links)
Im Rahmen dieser Arbeit wurde die Akustomigrationsresistenz von in Kupfertechnologie hergestellten SAW-Strukturen charakterisiert und diese mit dem Schädigungsverhalten von Al-basierten SAW-Strukturen unter gleichen Belastungsbedingungen verglichen. Dies wurde durch die Anwendung einer speziellen Power-SAW-Teststruktur ermöglicht. Das Schädigungsniveau wurde hierbei über die irreversible Verschiebung der Peakfrequenz bzw. durch Änderungen im elektrischen Widerstand sowie durch mikroskopische Untersuchung der Mikrostruktur beurteilt. Die durchgeführten SAW-Belastungsexperimente mit HF-Leistungen bis zu 4,5 W zeigten, dass das entwickelte Ta-Si-N/Cu/Ta-Si-N-System im Vergleich zur Al/Ti-Metallisierung eine Akustomigrationsresistenz besitzt, die um mehr als drei Größenordnungen höher ist als jene der Al/Ti-Metallisierung. Hohe SAW-Belastungen verursachten sowohl im Al- als auch im Cu-Testwandler Hügel- und Lochbildung. Während die Hügel in der Al/Ti-Metallisierung senkrecht zur Oberfläche bis zu einer Höhe von 1 µm und die Löcher bis hinab an die Ti-Schicht wuchsen, bildeten sich in den extrem belasteten Cu-basierten Wandlern nur flache Hügel und schmale Löcher aus, welche noch mit der Deckschicht vollständig bedeckt waren. Anhand von REM/EBSD, TEM sowie FIB-Untersuchungen konnte ein relevanter Zusammenhang zwischen der Mikrostruktur und dem Schädigungsverhalten aufgezeigt werden.

Page generated in 0.0848 seconds