• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 191
  • 3
  • 2
  • Tagged with
  • 199
  • 76
  • 53
  • 38
  • 32
  • 31
  • 22
  • 20
  • 19
  • 19
  • 19
  • 18
  • 18
  • 17
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo de um método multiclasse/multirresíduo para a determinação de pesticidas em amostras aquosas

Araujo, Mara Bertrand Campos de January 2004 (has links)
Este trabalho apresenta um estudo sobre o desenvolvimento do método de análise multiclasse/multirresíduo de pesticidas para ser aplicada às águas do Rio Caí, um dos formadores do Lago Guruba. A importância deste estudo se deve aos seguintes fatos: existe uma produção agrícola diversificada na bacia hidrográfica do Rio Caí, levando à utilização também diversificada de pesticidas (em tomo de 40 tipos); suas águas são utilizadas em várias cidades situadas na região e, além disso, Porto Alegre retira a água que consome do Lago Guaíba. Sendo assim, é necessário um controle permanente da qualidade dessas águas. O estudo consta da otimização de cada uma das duas etapas da análise: a pré-concentração, feita através da extração em fase sólida (SPE), e a análise propriamente dita feita através da cromatografia gasosa capilar com uma coluna apolar e outra medianamente polar, utilizando diferentes detectores (ECD, NPD, MSD). Na otimização da SPE foram estudados principalmente a técnica de empacotamento dos cartuchos, as fases sólidas, a adição de modificador de polaridade à amostra e o solvente de eluição. Foi feita a opção pelo empacotamento misto (seco e em seguida ressuspendido nos solventes de ativação e condicionamento), pela SPE em série (XAD-7 -> CI8 -> pNNPA), pela adição de metano I (solução 20%) como modificador de polaridade e pela eluição com uma solução binária de solventes (10% n-hexano em acetato de etila). Na otimização da análise cromatográfica foram estudados: o modo de injeção, o tempo de amostragem, a linearidade do detector, a faixa de linearidade, o LOD e o LOQ de cada pesticida O resultado mostrou que o método estudado permite a análise dos pesticidas citados, com resposta no ECD, com a faixa de recuperação entre 79,8 % para o forato e 120,2 % para a simazina, ficando abaixo apenas o mevinfós (60,2 %) e o folpet (67,0 %). Enquanto no GC-MSD a faixa de recuperação obtida foi de 71 % para a simazina a 127 % para o metolacloro. Ficaram fora da faixa de recuperação exigida os compostos que apresentam picos mal formados, o que leva a um alto desvio padrão relativo nas medidas das áreas, como malation, iprodiona, flumioxazin e cis-permetrina. O mevinfós e o acefato, que co-eluem, também têm a análise dificultada. Os LOD determinados estão em uma faixa que varia de 2,3 x 10-5 para o oxadiazon a 0,261 µg mL-¹ para a simazina, no GC-ECD e de 0,839 para o forato a 15,2 µg mL-¹ para a Iprodiona, no GC-MSD. Os LOQ variam de 7,8 x 10-5 para o oxadiazon a 0,868 para a simazina, no GC-ECD e de 2,8 para o forato a 50,6 µg mL-¹ para a iprodiona, no GC-MSD. As faixas de linearidade variaram de 5 a 25 ng mL-¹ para o oxadiazon até 297 a 990 ng mL-¹ para o mevinfós, no GC-ECD. Enquanto no GC-MSD as faixas encontradas foram de 593 a 5600 ng mL-¹ para o forato até a de 3370 a 6720 ng mL-¹ para a deltametrina. O método estudado e otimizado foi aplicado a uma amostra coletada no Rio Caí, em novembro de 2003. Embora esta amostra não tenha apresentado contaminação por resíduo dos pesticidas, nos níveis estudados, com a amostra real fortificada, analisada pela mesma metodologia, foram obtidas recuperações dentro dos níveis aceitáveis (entre 84,4 e 116,2%), na maioria dos pesticidas, para uma metodologia multiclasse-multirresíduo. As exceções foram metamidofós, mevinfós, acefato, captan, folpet e vamidotion (baixas recuperações) e ainda metalaxil e iprodiona (altas recuperações). / This work comprehends a study on the development of methodology for multiclasslmultiresidues pesticides analysis to be applied to the waters of Caí River, one of the main forming streams of Guaíba Lake (Rio Grande do Sul). The importance of this study is due to the following social-environmental characteristics: presence of a diversified and extensive farming activity along Caí Basin which in turn leads to a wide use of several pesticides (around 40 different types). Besides, 10081 ofthe towns located in the Caí Valley are supplied by water ftom Caí Rive, as well as Porto Alegre (state capital) which is supplied by water ftom Guatba Lake. Thus, it becomes necessary to bave a permanent and efficient control ofwater quality. This study encompass the optimization of two main steps in the analysis: (a) preconcentratio, done by solid phase extraction (SPE) and (b) final analysi, carried out by capillary gas chromatography, using one polar column and one medium polarity column and differents detectors, such as ECD, NPD and MSD. For the SPE optimizatio, the study focused on cartridge packing, the nature of the solid phases, the addition of a polarity modifier to the sample and the elution solvent. It was decided to choose mixed packing (dry, followed by resuspension in activating solvents and cond.itioning), tandem SPE (XAD-7-> CIS-> pNNP A), the addition of methanol (20% solution) as polarity modifier and elution with a binary solvent mixture (10% n-hexane in ethyl acetate). For the optimization of the chromatographic analysis the study focused on injection mode, sampling time, detector linear range, LOD LOQ and linear range for each pesticide under investigation. Experimental results pointed out that for ECD, the chosen methodology allows the analysis of the selected pesticides, with a recovery range between 79.8 % for phorate and 120.2 % for simazine. Mevinphos (60.2 %) e folpet (67.0 %) were below the minimum required value (70 %). For those with response on GC-MSD, the recovery ranges were: from 71 % for simazine to 127 % for metolachlor. Some pesticides, like malathio, iprodione, flumioxazin and cis-permethrin, gave values outside the required recovery range, because presented distorted peaks with a high RSD in the integration values. Mevinphos and acephate, exhibited co-elution. Experimental values for LOD were in the ranges of 2.3 x 10-5 for oxadiazon to 2.6 x 10-¹ µg mL-¹ for simazine, using GC-ECD, and of 8.4 x 10-¹ for phorate to 15.2 µg mL-¹ for iprodione, using GC-MSD. While values for LOQ ranged from 7.8 x 10-5 for oxadiazon to 8.7 x 10-¹ µg mL-¹ for simazine, using GC-ECD and from 2.8 for phorate to 50.6 µg mL-¹ for iprodione, using GC-MSD. The linearity ranges varied from 5 to 25 ng mL-¹ for oxadiazon, and up from 297 to 990 ng mL-¹ for mevinphos, using GC-ECD. However, for GC-MSD, the experimental values were 593 to 5,600 ng mL-¹ for phorate and up from 3,370 to 6,720 ng mL-¹ for deltamethrin. Afier optimization, the method was applied to a real sample from the Caí River, collected in November, 2003. Although this sample showed no contamination by residual pesticides, at the concentration leveI under investigation, with a fortified real sample, recovery ranges were within acceptable leveIs (between 84.4 to 116.2%), for most chosen pesticides, using a muhiclasslmuhiresidue methodology. Some exceptions were methamidophos, mevinphos, acephate, captan, folpet and vamidothion (lower recoveries) and meta1axil and iprodione (higher recoveries).
2

Determinação de Estanho em Tecidos de Ratas Por ICP-MS

BRANDAO, P. A. 21 May 2015 (has links)
Made available in DSpace on 2016-08-29T15:35:40Z (GMT). No. of bitstreams: 1 tese_8864_Poliane Aparecida Alves Brandão.pdf: 1591021 bytes, checksum: 2f1970e87c9c736cc721535a950ade0a (MD5) Previous issue date: 2015-05-21 / Os organoestânicos, principalmente o tributilestanho (TBT), são contaminantes ambientais, utilizados principalmente em tintas anti-incrustantes para navios. Eles sofrem bioacumulação e podem ser encontrados em mamíferos, inclusive em seres humanos. A principal fonte de exposição é a ingestão de alimentos contaminados. Esse estudo possuiu como objetivo a determinação de estanho em tecidos de ratas expostas cronicamente a TBT utilizando espectrometria de massas com plasma acoplado indutivamente (ICP-MS). Ratas Wistar adultas foram usadas na experimentação, sendo divididas dois grupos: o grupo exposto a 100 ng kg-1 dia-1 de TBT por 15 dias e o grupo de referência que recebeu somente o veículo durante o mesmo período de exposição. Ao final da exposição, os animais foram sacrificados e coletados plasma, coração, rim, pulmão, fígado e ovário para análise. As amostras foram secas em estufa por 72 horas e pulverizadas. A determinação de estanho foi realizada por ICP-MS após a digestão ácida assistida por micro-ondas de uma amostra com aproximadamente 100 mg. O limite de detecção (LD) calculado foi 4,3 ng L-1, o que permite a determinação de estanho em amostras de tecidos de animais usados para experimentação. A exatidão foi verificada pela análise do material de referência certificado de urina, Seronorm Urine (54,6 ± 2,7 µg L-1), tendo como resultado 50,1 ± 3,8 µg L-1. A concentração de estanho foi determinada em amostras de plasma, coração, rim, pulmão, fígado e ovário do grupo exposto a TBT e do grupo controle. Houve diferença estatisticamente significativa entre os dois grupos para todas as amostras analisadas. As diferenças entre os grupos foram mais pronunciadas nas amostras de fígado e rim. Além disso, este estudo mostrou que a presença de estanho no organismo de ratas distribui-se pelos tecidos acarretando em alterações morfofisiológicas já descritas em ovários, coração e fígado.
3

Estudo de um método multiclasse/multirresíduo para a determinação de pesticidas em amostras aquosas

Araujo, Mara Bertrand Campos de January 2004 (has links)
Este trabalho apresenta um estudo sobre o desenvolvimento do método de análise multiclasse/multirresíduo de pesticidas para ser aplicada às águas do Rio Caí, um dos formadores do Lago Guruba. A importância deste estudo se deve aos seguintes fatos: existe uma produção agrícola diversificada na bacia hidrográfica do Rio Caí, levando à utilização também diversificada de pesticidas (em tomo de 40 tipos); suas águas são utilizadas em várias cidades situadas na região e, além disso, Porto Alegre retira a água que consome do Lago Guaíba. Sendo assim, é necessário um controle permanente da qualidade dessas águas. O estudo consta da otimização de cada uma das duas etapas da análise: a pré-concentração, feita através da extração em fase sólida (SPE), e a análise propriamente dita feita através da cromatografia gasosa capilar com uma coluna apolar e outra medianamente polar, utilizando diferentes detectores (ECD, NPD, MSD). Na otimização da SPE foram estudados principalmente a técnica de empacotamento dos cartuchos, as fases sólidas, a adição de modificador de polaridade à amostra e o solvente de eluição. Foi feita a opção pelo empacotamento misto (seco e em seguida ressuspendido nos solventes de ativação e condicionamento), pela SPE em série (XAD-7 -> CI8 -> pNNPA), pela adição de metano I (solução 20%) como modificador de polaridade e pela eluição com uma solução binária de solventes (10% n-hexano em acetato de etila). Na otimização da análise cromatográfica foram estudados: o modo de injeção, o tempo de amostragem, a linearidade do detector, a faixa de linearidade, o LOD e o LOQ de cada pesticida O resultado mostrou que o método estudado permite a análise dos pesticidas citados, com resposta no ECD, com a faixa de recuperação entre 79,8 % para o forato e 120,2 % para a simazina, ficando abaixo apenas o mevinfós (60,2 %) e o folpet (67,0 %). Enquanto no GC-MSD a faixa de recuperação obtida foi de 71 % para a simazina a 127 % para o metolacloro. Ficaram fora da faixa de recuperação exigida os compostos que apresentam picos mal formados, o que leva a um alto desvio padrão relativo nas medidas das áreas, como malation, iprodiona, flumioxazin e cis-permetrina. O mevinfós e o acefato, que co-eluem, também têm a análise dificultada. Os LOD determinados estão em uma faixa que varia de 2,3 x 10-5 para o oxadiazon a 0,261 µg mL-¹ para a simazina, no GC-ECD e de 0,839 para o forato a 15,2 µg mL-¹ para a Iprodiona, no GC-MSD. Os LOQ variam de 7,8 x 10-5 para o oxadiazon a 0,868 para a simazina, no GC-ECD e de 2,8 para o forato a 50,6 µg mL-¹ para a iprodiona, no GC-MSD. As faixas de linearidade variaram de 5 a 25 ng mL-¹ para o oxadiazon até 297 a 990 ng mL-¹ para o mevinfós, no GC-ECD. Enquanto no GC-MSD as faixas encontradas foram de 593 a 5600 ng mL-¹ para o forato até a de 3370 a 6720 ng mL-¹ para a deltametrina. O método estudado e otimizado foi aplicado a uma amostra coletada no Rio Caí, em novembro de 2003. Embora esta amostra não tenha apresentado contaminação por resíduo dos pesticidas, nos níveis estudados, com a amostra real fortificada, analisada pela mesma metodologia, foram obtidas recuperações dentro dos níveis aceitáveis (entre 84,4 e 116,2%), na maioria dos pesticidas, para uma metodologia multiclasse-multirresíduo. As exceções foram metamidofós, mevinfós, acefato, captan, folpet e vamidotion (baixas recuperações) e ainda metalaxil e iprodiona (altas recuperações). / This work comprehends a study on the development of methodology for multiclasslmultiresidues pesticides analysis to be applied to the waters of Caí River, one of the main forming streams of Guaíba Lake (Rio Grande do Sul). The importance of this study is due to the following social-environmental characteristics: presence of a diversified and extensive farming activity along Caí Basin which in turn leads to a wide use of several pesticides (around 40 different types). Besides, 10081 ofthe towns located in the Caí Valley are supplied by water ftom Caí Rive, as well as Porto Alegre (state capital) which is supplied by water ftom Guatba Lake. Thus, it becomes necessary to bave a permanent and efficient control ofwater quality. This study encompass the optimization of two main steps in the analysis: (a) preconcentratio, done by solid phase extraction (SPE) and (b) final analysi, carried out by capillary gas chromatography, using one polar column and one medium polarity column and differents detectors, such as ECD, NPD and MSD. For the SPE optimizatio, the study focused on cartridge packing, the nature of the solid phases, the addition of a polarity modifier to the sample and the elution solvent. It was decided to choose mixed packing (dry, followed by resuspension in activating solvents and cond.itioning), tandem SPE (XAD-7-> CIS-> pNNP A), the addition of methanol (20% solution) as polarity modifier and elution with a binary solvent mixture (10% n-hexane in ethyl acetate). For the optimization of the chromatographic analysis the study focused on injection mode, sampling time, detector linear range, LOD LOQ and linear range for each pesticide under investigation. Experimental results pointed out that for ECD, the chosen methodology allows the analysis of the selected pesticides, with a recovery range between 79.8 % for phorate and 120.2 % for simazine. Mevinphos (60.2 %) e folpet (67.0 %) were below the minimum required value (70 %). For those with response on GC-MSD, the recovery ranges were: from 71 % for simazine to 127 % for metolachlor. Some pesticides, like malathio, iprodione, flumioxazin and cis-permethrin, gave values outside the required recovery range, because presented distorted peaks with a high RSD in the integration values. Mevinphos and acephate, exhibited co-elution. Experimental values for LOD were in the ranges of 2.3 x 10-5 for oxadiazon to 2.6 x 10-¹ µg mL-¹ for simazine, using GC-ECD, and of 8.4 x 10-¹ for phorate to 15.2 µg mL-¹ for iprodione, using GC-MSD. While values for LOQ ranged from 7.8 x 10-5 for oxadiazon to 8.7 x 10-¹ µg mL-¹ for simazine, using GC-ECD and from 2.8 for phorate to 50.6 µg mL-¹ for iprodione, using GC-MSD. The linearity ranges varied from 5 to 25 ng mL-¹ for oxadiazon, and up from 297 to 990 ng mL-¹ for mevinphos, using GC-ECD. However, for GC-MSD, the experimental values were 593 to 5,600 ng mL-¹ for phorate and up from 3,370 to 6,720 ng mL-¹ for deltamethrin. Afier optimization, the method was applied to a real sample from the Caí River, collected in November, 2003. Although this sample showed no contamination by residual pesticides, at the concentration leveI under investigation, with a fortified real sample, recovery ranges were within acceptable leveIs (between 84.4 to 116.2%), for most chosen pesticides, using a muhiclasslmuhiresidue methodology. Some exceptions were methamidophos, mevinphos, acephate, captan, folpet and vamidothion (lower recoveries) and meta1axil and iprodione (higher recoveries).
4

Estudo de um método multiclasse/multirresíduo para a determinação de pesticidas em amostras aquosas

Araujo, Mara Bertrand Campos de January 2004 (has links)
Este trabalho apresenta um estudo sobre o desenvolvimento do método de análise multiclasse/multirresíduo de pesticidas para ser aplicada às águas do Rio Caí, um dos formadores do Lago Guruba. A importância deste estudo se deve aos seguintes fatos: existe uma produção agrícola diversificada na bacia hidrográfica do Rio Caí, levando à utilização também diversificada de pesticidas (em tomo de 40 tipos); suas águas são utilizadas em várias cidades situadas na região e, além disso, Porto Alegre retira a água que consome do Lago Guaíba. Sendo assim, é necessário um controle permanente da qualidade dessas águas. O estudo consta da otimização de cada uma das duas etapas da análise: a pré-concentração, feita através da extração em fase sólida (SPE), e a análise propriamente dita feita através da cromatografia gasosa capilar com uma coluna apolar e outra medianamente polar, utilizando diferentes detectores (ECD, NPD, MSD). Na otimização da SPE foram estudados principalmente a técnica de empacotamento dos cartuchos, as fases sólidas, a adição de modificador de polaridade à amostra e o solvente de eluição. Foi feita a opção pelo empacotamento misto (seco e em seguida ressuspendido nos solventes de ativação e condicionamento), pela SPE em série (XAD-7 -> CI8 -> pNNPA), pela adição de metano I (solução 20%) como modificador de polaridade e pela eluição com uma solução binária de solventes (10% n-hexano em acetato de etila). Na otimização da análise cromatográfica foram estudados: o modo de injeção, o tempo de amostragem, a linearidade do detector, a faixa de linearidade, o LOD e o LOQ de cada pesticida O resultado mostrou que o método estudado permite a análise dos pesticidas citados, com resposta no ECD, com a faixa de recuperação entre 79,8 % para o forato e 120,2 % para a simazina, ficando abaixo apenas o mevinfós (60,2 %) e o folpet (67,0 %). Enquanto no GC-MSD a faixa de recuperação obtida foi de 71 % para a simazina a 127 % para o metolacloro. Ficaram fora da faixa de recuperação exigida os compostos que apresentam picos mal formados, o que leva a um alto desvio padrão relativo nas medidas das áreas, como malation, iprodiona, flumioxazin e cis-permetrina. O mevinfós e o acefato, que co-eluem, também têm a análise dificultada. Os LOD determinados estão em uma faixa que varia de 2,3 x 10-5 para o oxadiazon a 0,261 µg mL-¹ para a simazina, no GC-ECD e de 0,839 para o forato a 15,2 µg mL-¹ para a Iprodiona, no GC-MSD. Os LOQ variam de 7,8 x 10-5 para o oxadiazon a 0,868 para a simazina, no GC-ECD e de 2,8 para o forato a 50,6 µg mL-¹ para a iprodiona, no GC-MSD. As faixas de linearidade variaram de 5 a 25 ng mL-¹ para o oxadiazon até 297 a 990 ng mL-¹ para o mevinfós, no GC-ECD. Enquanto no GC-MSD as faixas encontradas foram de 593 a 5600 ng mL-¹ para o forato até a de 3370 a 6720 ng mL-¹ para a deltametrina. O método estudado e otimizado foi aplicado a uma amostra coletada no Rio Caí, em novembro de 2003. Embora esta amostra não tenha apresentado contaminação por resíduo dos pesticidas, nos níveis estudados, com a amostra real fortificada, analisada pela mesma metodologia, foram obtidas recuperações dentro dos níveis aceitáveis (entre 84,4 e 116,2%), na maioria dos pesticidas, para uma metodologia multiclasse-multirresíduo. As exceções foram metamidofós, mevinfós, acefato, captan, folpet e vamidotion (baixas recuperações) e ainda metalaxil e iprodiona (altas recuperações). / This work comprehends a study on the development of methodology for multiclasslmultiresidues pesticides analysis to be applied to the waters of Caí River, one of the main forming streams of Guaíba Lake (Rio Grande do Sul). The importance of this study is due to the following social-environmental characteristics: presence of a diversified and extensive farming activity along Caí Basin which in turn leads to a wide use of several pesticides (around 40 different types). Besides, 10081 ofthe towns located in the Caí Valley are supplied by water ftom Caí Rive, as well as Porto Alegre (state capital) which is supplied by water ftom Guatba Lake. Thus, it becomes necessary to bave a permanent and efficient control ofwater quality. This study encompass the optimization of two main steps in the analysis: (a) preconcentratio, done by solid phase extraction (SPE) and (b) final analysi, carried out by capillary gas chromatography, using one polar column and one medium polarity column and differents detectors, such as ECD, NPD and MSD. For the SPE optimizatio, the study focused on cartridge packing, the nature of the solid phases, the addition of a polarity modifier to the sample and the elution solvent. It was decided to choose mixed packing (dry, followed by resuspension in activating solvents and cond.itioning), tandem SPE (XAD-7-> CIS-> pNNP A), the addition of methanol (20% solution) as polarity modifier and elution with a binary solvent mixture (10% n-hexane in ethyl acetate). For the optimization of the chromatographic analysis the study focused on injection mode, sampling time, detector linear range, LOD LOQ and linear range for each pesticide under investigation. Experimental results pointed out that for ECD, the chosen methodology allows the analysis of the selected pesticides, with a recovery range between 79.8 % for phorate and 120.2 % for simazine. Mevinphos (60.2 %) e folpet (67.0 %) were below the minimum required value (70 %). For those with response on GC-MSD, the recovery ranges were: from 71 % for simazine to 127 % for metolachlor. Some pesticides, like malathio, iprodione, flumioxazin and cis-permethrin, gave values outside the required recovery range, because presented distorted peaks with a high RSD in the integration values. Mevinphos and acephate, exhibited co-elution. Experimental values for LOD were in the ranges of 2.3 x 10-5 for oxadiazon to 2.6 x 10-¹ µg mL-¹ for simazine, using GC-ECD, and of 8.4 x 10-¹ for phorate to 15.2 µg mL-¹ for iprodione, using GC-MSD. While values for LOQ ranged from 7.8 x 10-5 for oxadiazon to 8.7 x 10-¹ µg mL-¹ for simazine, using GC-ECD and from 2.8 for phorate to 50.6 µg mL-¹ for iprodione, using GC-MSD. The linearity ranges varied from 5 to 25 ng mL-¹ for oxadiazon, and up from 297 to 990 ng mL-¹ for mevinphos, using GC-ECD. However, for GC-MSD, the experimental values were 593 to 5,600 ng mL-¹ for phorate and up from 3,370 to 6,720 ng mL-¹ for deltamethrin. Afier optimization, the method was applied to a real sample from the Caí River, collected in November, 2003. Although this sample showed no contamination by residual pesticides, at the concentration leveI under investigation, with a fortified real sample, recovery ranges were within acceptable leveIs (between 84.4 to 116.2%), for most chosen pesticides, using a muhiclasslmuhiresidue methodology. Some exceptions were methamidophos, mevinphos, acephate, captan, folpet and vamidothion (lower recoveries) and meta1axil and iprodione (higher recoveries).
5

Aplicação de um modelo constitutivo para a análise das deformações em um solo compactado não saturado

Maria de Morais Sobreira Valença, Juliana January 2002 (has links)
Made available in DSpace on 2014-06-12T17:42:08Z (GMT). No. of bitstreams: 2 arquivo6725_1.pdf: 1140870 bytes, checksum: 84512609f648cf6d703e0baa0cc282e4 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2002 / O presente trabalho tem por objetivo analisar a aplicabilidade do modelo elastoplástico desenvolvido por ALONSO, GENS e JOSA (1990) na análise do comportamento tensão-deformação de um solo compactado não saturado. O modelo foi utilizado na previsão do comportamento de amostras compactadas estaticamente, em diferentes condições de umidade e densidade, e ensaiadas numa célula edométrica com controle de sucção, aplicando-se carregamentos verticais e mantendo-se uma sucção constante, igual a 150kPa, até atingir-se um valor pré-definido de tensão vertical (50kPa, 100kPa, 400kPa), quando procedia-se a inundação da amostra. Na definição das equações do modelo foram utilizados dois conjuntos de parâmetros, sendo o primeiro obtido por PERAZZO (1996) através de ensaios com tensão vertical de consolidação constante, variando a sucção e ensaios com sucção constante variando a tensão vertical de consolidação; e o segundo foi obtido a partir de ensaios edométricos com sucção constante e tensão vertical variável seguido de inundação sob tensão vertical constante. Com base nas comparações das curvas tensão-deformação obtidas nos ensaios com as obtidas pelo modelo, são feitas considerações sobre a capacidade do modelo em prever o comportamento das amostras compactadas sob diferentes condições de compactação
6

Validação experimental de soluções de flexibilidade elástica aplicáveis a amostras SE (B)/

Carvalho Júnior, J. F. January 2016 (has links)
Dissertação (Mestrado em Engenharia Mecânica) - Centro Universitário FEI, São Bernardo do Campo, 2016.
7

Caracterização química e determinação de impurezas de amostras de processo de berílio

Carvalho, Leonel Mathry de, Instituto de Engenharia Nuclear 12 1900 (has links)
Submitted by Marcele Costal de Castro (costalcastro@gmail.com) on 2017-10-11T17:01:56Z No. of bitstreams: 1 LEONEL MATHRY CARVALHO M.pdf: 4959457 bytes, checksum: 2e177dbed7d103f8b43486cdd30f26c7 (MD5) / Made available in DSpace on 2017-10-11T17:01:56Z (GMT). No. of bitstreams: 1 LEONEL MATHRY CARVALHO M.pdf: 4959457 bytes, checksum: 2e177dbed7d103f8b43486cdd30f26c7 (MD5) Previous issue date: 1992-12 / O Brasil é o maior produtor mundial de berilo (3BeO.Al203.6Si02) e começou recentemente a produção de compostos de berílio em uma usina piloto na cidade de Governador Valadares (MG - Brasil). O objetivo deste trabalho é o desenvolvimento de metodologia para determinação de impurezas a nível de traços e macro constituintes na faixa de dezenas de % para auxiliar o controle analítico do processo de produção da usina, bem como a caracterização de compostos de berílio. Foram desenvolvidas duas técnicas distintas para separação de impurezas e purificação de compostos de berílio. A primeira, utilizando a complexação com EDTA, separou e reduziu algumas impurezas a níveis menores que 1 ug/ml. A segunda utilizou resina quelante (Chelex -100), chegando-se a uma eficiência de separação entre 75-97%, conforme o elemento separado. Padrão de alta pureza de óxido de berílio foi obtido a partir da purificação de Be(OH)2. A verificação de impurezas por fluorescência de RX apresentou somente traços de Cu e Si, < 1 % Fe e Mn, Zn, Ca, Al, Na e S foram completamente retirados. O teor de berílio foi determinado por espectroscopia de emissão em plasma de argônio - DCP e comparado com método gravimétrico clássico como BeO. Os resultados foram concordantes (49,2 +/- 0,2 % e 48,3 +/- 0,1 % respectivamente) para intervalo de confiança de 95 %. Um método gravimétrico de baixa temperatura para determinação de berílio foi também estudado utilizando oxina e forno de microondas para obtenção do composto gravimétrico. Um total de 24 elementos incluindo macro e micro constituintes foram determinados por espectroscopia de emissão em plasma e/ou métodos espectrofotométricos. A separação de Be/B foi estudada usando resina aniônica forte em meio de polialcóois. Um estudo mais detalhado das condições de equilíbrio é necessário. Este trabalho foi realizado no Laboratório de Análise Mineral (LAM) da Comissão Nacional de Energia Nuclear - RJ. / Brazil is the greatest world producer of beryl (3BeO.Al203.6Si02) and has recently begun to produce beryllium compounds by means of a pilot plant constructed at Governador Valadares city (MG - Brazil). The aim of this work was the determination of trace level impurities and macro constituents in the tenth % range to support analytical control process of plant production and characterization of beryllium compounds. The impurities separations and purification process was developed by two steps procedure. The first one using EDTA complexation has separated and reduced some impurities to less than 1 u.g/ml level. In the second one it was used a chelating resin (Chelex 100) and the separation efficiency was about 75 - 97 % related with the element tested. High pure beryllium oxide standard was obtained from purification of Be(OH)2. The RX fluorescence presented only traces of Cu and Si, < 1 % Fe and Mn, Zn, Ca, Al, Na and S were completely removed. The beryllium content was determined by direct atomic emission spectroscopy in argon plasma (DCP) and compared with classic gravimetric method as BeO. The results were in agreement (49,2+/-0,2 %and 48,3+/-0,l % respectively) between 95 % of confidence. A low temperature gravimetric method for beryllium determination was also studied using Oxine with microwave furnace. A total of 24 elements including macro and trace level were determined by DCP and/or spectrophotometric methods. The Be/B separation was studied using anionic resin in poyalcohols medium. A more detailed study of equilibrium conditions is necessary. This work was realized at Laboratório de Análise Mineral (LAM) of Comissão Nacional de Energia Nuclear - RJ (CNEN).
8

Associação entre papiloma vírus humano e câncer gástrico: estudo genômico

Cândido, Ana Claudia Luna 04 September 2012 (has links)
Submitted by Heitor Rapela Medeiros (heitor.rapela@ufpe.br) on 2015-03-04T14:26:35Z No. of bitstreams: 2 biblioteca - claudia.pdf: 1718092 bytes, checksum: b722f27aa93ca90535409b6846ae7dda (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-04T14:26:35Z (GMT). No. of bitstreams: 2 biblioteca - claudia.pdf: 1718092 bytes, checksum: b722f27aa93ca90535409b6846ae7dda (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2012-09-04 / O Papiloma Vírus Humano - HPV é um dos mais importantes vírus relacionados com a carcinogênese, já sendo conhecido seu papel na gênese do carcinoma cervical uterino. A maioria dos casos de câncer gástrico está relacionada a um agente infeccioso: Helicobacter Pylori. Outros agentes infecciosos como os vírus Epsten-Barr e HPV são relatados associados ao câncer gástrico. Objetivo: Este estudo visa investigar a associação do HPV em pacientes com câncer gástrico e comparar a um grupo controle sem neoplasia. Método: Foram analisadas 40 amostras parafinadas provenientes de portadores de câncer gástrico e 40 amostras de pacientes do grupo controle submetidos à endoscopia e biópsia de mucosa gástrica normal e sangue periférico, no período de 2008 a 2009. O material coletado foi examinado por Reação de Cadeia de Polimerase - PCR para gene da região L1-HPV. O DNA extraído foi amplificado em dois sistemas de reação utilizando-se dois pares de primers: MY09/MY11 (fragmento de 450pb) e GP+5/GP+6 (fragmento de 150pb). Foi utilizada água Mili-Q como controle negativo da reação, sendo o controle positivo uma mistura de 01μL de sangue humano acrescido de 0,25μL de plasmídeo p BR322(HPV16). Resultados: Foram identificados em quatro pacientes com CG a presença de HPV associado à mucosa tumoral, nos pacientes sem neoplasia gástrica foram identificados 10 casos de HPV associado à mucosa gástrica. Conclusão: No presente estudo não encontramos indícios de associação significativa do HPV ao câncer gástrico (p=0,077).
9

Estudo comparativo de m?todos de extra??o para determina??o de fluazuron em plasma bovino por cromatografia l?quida de alta efici?ncia com detec??o em ultravioleta. / Comparison of extraction methods for determining fluazuron in bovine plasma by high-performance liquid chromatography with UV detection.

Ferreira, Thais Paes 11 May 2016 (has links)
Submitted by Leticia Schettini (leticia@ufrrj.br) on 2016-10-04T13:00:01Z No. of bitstreams: 1 2016 - Thais Paes Ferreira.pdf: 1131707 bytes, checksum: c98267296d6293f703188fe1291622db (MD5) / Made available in DSpace on 2016-10-04T13:00:01Z (GMT). No. of bitstreams: 1 2016 - Thais Paes Ferreira.pdf: 1131707 bytes, checksum: c98267296d6293f703188fe1291622db (MD5) Previous issue date: 2016-05-11 / Fluazuron is a benzoylphenylurea acarine growth inhibitor that is marketed for the control of cattle tick. Although the growth regulators are widely studied class, the number of papers describing analytical methods for determining the fluazuron in plasma samples is reduced. The development of a simple and fast analytical method for quantifying fluazuron in bovine plasma by HPLC-UV enables the evaluation of drug plasma profile and can be applied on bioavailability analysis of formulations containing fluazuron. In recent years there has been a technological breakthrough for chromatographic instrumentation, providing rapid, robust and sensitive methods, but the pretreatment of the sample stage becomes the limiting factor in this process. New extraction methods have been developed, however are often complex, expensive methods and are not as sophisticated to handle complex matrices, such as plasma. The aim of this study was a comparative study of three extraction methods: LLE, SPE and matrix solid phase dispersion (MSPD). Pooled plasma samples were used as biological material, partly as raw samples and partly spiked with concentrations of fluazuron. For each extraction method (with exception of DMFS) was conducted using various solvents (ethyl acetate, dichloromethane, diethyl ether, hexane and acetonitrile) in order to evaluate the best extractor solvent. After the extractions the samples were concentrated and analyzed by HPLC/UV. The chromatographic separation was achieved on Kromasil C18 column preceded by guard column of matching chemistry, with mobile phase of acetonitrile: water (80:20, v/v) at flow rate of 1.0 mL/min. The comparative analysis of the extraction procedures was based on selectivity, precision and accuracy of the method. Results showed that LLE not presented accuracy (< 80 and >120%) and precision (CV > 15%) with any solvent tested. SPE method showed good accuracy (80-120%) and precision (CV < 15%) for ethyl acetate, dichloromethane and diethyl ether. MSPD method using ethyl acetate solvent showed good accuracy and precision. However, SPE also allows a lower solvent consumption and shorter analysis time. The validation of the analytical method showed linearity, selectivity, precision, accuracy and, absence matrix effects and residual, thus proving it as suitable for routine analysis; This method showed to be an important investigative tool in the analysis of fluazuron plasma concentration in cattle. Fluazuron topical administration in bovine reached the systemic circulation (Cmax=62,8 ng/mL), was absorbed (tmax=48 hs), while maintaining quantifiable blood plasma levels for up to 14 days after the treatment with a 2,5 mg/Kg dosage. / Fluazuron ? um inibidor do crescimento da classebenzoilfenilur?ia, sendo comercializado para o controle de carrapatos do gado. Embora a classe de reguladores de crescimento sejam amplamente estudada, o n?mero de artigos que descrevem os m?todos anal?ticos para a determina??o do fluazurom em amostras de plasma ? escasso. O desenvolvimento de um m?todo anal?tico simples e r?pido para quantificar fluazuron em plasma bovino por CLAEUV permite a avalia??o do perfil plasm?tico do f?rmaco e pode ser aplicado na an?lise de biodisponibilidade de formula??es contendo fluazurom. Nos ?ltimos anos, tem acontecido um avan?o tecnol?gico para a instrumenta??o cromatogr?fica, proporcionando m?todos r?pidos, eficazes e sens?veis, mas a etapa de pr?-tratamento da amostra torna-se o fator limitante neste processo. Novos m?todos de extra??o t?m sido desenvolvidos, no entanto, muitas das vezes s?om?todos complexos, caros e n?o t?o sofisticados para matrizes complexas como o plasma. O objetivo deste estudo foi um estudo comparativo de tr?s m?todos de extra??o: extra??o l?quido-l?quido (ELL), extra??o em fase s?lida (EFS) e dispers?o de matriz em fase s?lida (DMFS). Ums mistura de amostras de plasma foi utilizada como material biol?gico, uma parte como amostra bruta e outra parcialmente enriquecida com concentra??es de fluazuron. Para cada m?todo de extra??o (exceto DMFS) foram analisadosdiversos solventes (acetato de etila, diclorometano, ?ter diet?lico, hexano e acetonitrila), a fim de avaliar o melhor solvente extrator. Ap?s as extra??es, as amostras foram concentradas e analisadas por CLAE/UV. A separa??o cromatogr?f ica foi obtida na coluna Kromasil C18 precedida de pr?-coluna de fase qu?mica correspondente, com fase m?vel de acetonitrila: ?gua (80:20, v/v) a um fluxo de 1,0 mL /min. A an?lise comparativa dos procedimentos de extra??o foi baseada na seletividade, precis?o e exatid?o do m?todo. Os resultados mostraram que a precis?o ELL n?o apresentou exatid?o (<80 e> 120%) e precis?o (CV> 15%) com nenhum dos solventes analisados. O m?todo EFS mostrou boa exatid?o (80-120%) e precis?o (CV <15%) para o acetato de etila, diclorometano e ?ter diet?lico. O m?todo de DMFS utilizando o solvente acetato de etila mostrou boa exatid?o e precis?o. No entanto, a EFS tamb?m permite um menor consumo de solventes e um tempo curto de an?lise; A valida??o do m?todo anal?tico mostrou linearidade, seletividade, precis?o, exatid?o e, aus?ncia de efeitos de matriz e residual, demonstrando-se adequado para an?lises de rotina; Este m?todo mostrou-se uma ferramenta de investiga??o importante na an?lise de concentra?? plasm?tica em bovinos. Fluazuron administrado por via t?pica em bovinos atingiu a circula??o sist?mica (Cmax = 62,8 ng /ml) e foi absorvido (Tm?x = 48 Hs), se mantendo quantificav?l em n?veis plasm?ticos por at? 14 dias ap?s o tratamento com uma dosagem de 2,5 mg / kg.
10

Refinamento de estruturas cristalinas por difração de raios-x pelo método de mínimos quadrados utilizando dados de amostras policristalinas. / Refinement of crystal structures by x-ray diffraction using the method of least squares and data from polycrystalline samples.

Simone, Carlos Alberto de 11 March 1983 (has links)
A estrutura da florencita foi refinada pelo método de mínimos quadrados, utilizando dados experimentais obtidos através do método de Debye-Scherrer. A coleta dos dados das intensidades integradas foi feita através da leitura do difratograma de pó por um microdensitômetro óptico automático, e empregando métodos de análise numérica para fazer a integração da função (2&#952,Y), tabelada a pontos eqüidistantes. Foram observados 14 picos de difração e as reflexões que se superpunham contribuindo para as intensidades dos picos foram identificadas e suas contribuições levadas em conta através de seus fatores de multiplicidade. O refinamento foi feito com o programa POWLS (Powder Least Squares) e inicialmente foram fornecidos os parâmetros posicionais dos átomos da Goyazita, que é isomorfa com a florencita. As intensidades observadas foram corrigidas pelos fatores de Lorentz-polarização e adsorção. O índice de discordância R atingido para os 14 picos de difração observados foi de 0.097. A fórmula molecular da florencita é CeAl3(PO4)2(OH)6. O composto cristaliza no sistema hexagonal com parâmetros de rede ao=6.96&#197; co=16.33&#197; &#945= &#946 = 90&#176; &#947=120&#176; V=685.07&#1973. O grupo espacial é R3m com Z=3 e densidade calculada igual a 3.67g.cm-3. / The crystal structure of the florencita was refined by least squares using experimental data obtained with the Debye-Scherrer method. An automatic optical microdensitometer was used for the data collection from powder difractogram and numerical analysis methods for the integration of the function (2&#952,Y) which is tabulated at equidistant points. 14 diffraction peaks were observed, reflections which superpose contributing to the same peak were identified and their contributions were taken in account using multiplicity factors. The program POWLS (Powder Least Squares) was used for the refinement and initially the positional parameters of the atoms of the Goyazite, which is isomorfous with the florencita were used. Intensities were corrected for the Lorentz, polarization and absorption factors. The final R factor for the 14 peaks was of 0.097. The molecular formula of the florencitais CeAl3(PO4)2(OH)6. It crystallizes in the hexagonal system, space group R3m with cell ao=6.96&#197; co=16.33&#197; &#945= &#946 = 90&#176; &#947=120&#176; V=685.07&#1973.

Page generated in 0.0749 seconds