• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • Tagged with
  • 17
  • 17
  • 8
  • 7
  • 6
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Estudo sobre a determinação de paládio em amostras biológicas pelo método de análise por ativação com nêutrons / Study on the determination of palladium in biological samples for the method of analysis for activation with nêutrons

Cavalcante, Cassio Queiroz 12 April 2007 (has links)
O paládio é um dos elementos do grupo da platina presente em baixos teores na natureza. Nos últimos anos com o crescente uso deste elemento nos catalisadores automotivos e nas investigações para o desenvolvimento de drogas anti-tumorais, as suas determinações tornaram-se de grande interesse. No presente trabalho foi feito um estudo sobre a determinação de paládio em amostras biológicas e materiais de referência pelo método de análise por ativação puramente instrumental com nêutrons térmicos (INAA) e epitérmicos (ENAA) separadamente, bem como pela ENAA após separação do paládio por meio das técnicas de extração com solventes e de extração em uma coluna de fase sólida. As amostras analisadas no presente estudo foram: material de referência BCR 723 – Palladium, Platinum and Rhodium in road dust, material catalisador automotivo do teste de proficiência do CCQM-P63 e amostras de tecido bovino contendo Pd preparadas no laboratório. As irradiações das amostras e padrão para INAA e ENAA foram realizadas no reator IEA-R1 sob fluxo de nêutrons térmicos da ordem de 4 x 10 12 n cm-2 s-1 e por um período de 4 h nas irradiações térmicas e de 16 h nas epitérmicas. Depois de adequados tempos de decaimento as medições das atividades gama induzidas das amostras e padrões foram feitas usando um espectrômetro de raios gama constituído de um detector de Ge hiperpuro e eletrônica associada. A concentração de paládio foi calculada pelo método comparativo. O paládio foi medido pelo pico de 88,0 keV do 109Pd localizado numa região do espectro de baixa energia onde ocorre a interferência de picos de raios X, da radiação de freiamento e do efeito Compton do 24Na. A pré-separação do paládio dos elementos interferentes pelo método de extração com solventes foi feita por meio da extração do complexo formado entre o paládio e a dimetilglioxima em clorofórmio. O método de separação por meio da extração em fase sólida consistiu na retenção do paládio em uma coluna de fase sólida de octadecilsilano, contendo complexante N,N-dietil-N’-benzoil tiouréia (DEBT) adsorvido e em seguida fazendo a eluição de paládio com etanol. Alíquotas das soluções resultantes da préseparação, livres de elementos interferentes, foram pipetadas em cápsulas de polietileno e submetidas à ENAA. A comparação entre os resultados de paládio obtidos por diferentes procedimentos de ativação com nêutrons indicou uma boa concordância e uma boa precisão com desvios padrão relativos variando de 2 a 14%. Os rendimentos de recuperação na pré-separação de paládio variaram de 70,9 a 97,7 % e estes resultados dependem do tipo de matriz e da técnica de pré-separação aplicada. Os valores de limite de detecção obtidos para análise do tecido muscular bovino foram de 11,0 e 0,4 μg g-1 pelos métodos de INAA e ENAA, respectivamente. Para o caso do material de referência BCR-723 foram obtidos limites de 24,0 e 1,7 μg g-1, respectivamente na INAA e ENAA e estes resultados indicaram que o limite de detecção depende do tipo de matriz analisada. A irradiação com nêutrons epitérmicos permitiu aumento da sensibilidade devido à redução do problema de interferência e além disso a aplicação da separação prévia do paládio seguida de ENAA proporcionou um aumento da sensibilidade quando comparada com ENAA purament e instrumental. / Palladium is one of platinum group elements present in the nature at very low concentrations. However with the use of this element in the automobile catalyzers Pd became a new pollutant. Besides, Pd has been studied in the preparation of new antitumour drugs. Consequently, there is a need to determine Pd concentrations in biological and environmental samples. This study presents palladium results obtained in the analysis of biological samples and reference materials using instrumental thermal and epithermal neutron activation analysis (INAA and ENAA). The solvent extraction and solid phase extraction separation methods were also applied before ENAA. The samples analyzed in this study were, reference material BCR 723–Palladium, Platinium and Rhodium in road dust, CCQM-P63 automotive catalyst material of the Proficiency Test and bovine tissue samples containing palladium prepared in the laboratory. Samples and palladium synthetic standard were irradiated at the IEA-R1 nuclear research reactor under thermal neutron flux of about 4 x 10 12 n cm-2 s-1, during a period of 4 and 16 h for INAA and ENAA, respectively. The induced gamma activity of 109Pd to the sample and standard was measured using a hyperpure Ge detector coupled to a gamma ray spectrometer. The palladium concentration was calculated by comparative method. The gamma ray energy of 109Pd radioisotope measured was of 88.0 keV, located in a spectrum region of low energy where occurs the interference of X rays, “bremsstrahlung" radiations, as well as Compton effect of 24Na. The pre-separation of palladium from interfering elements by solvent extraction was performed using dimethylglyoxime complexant and chloroform as diluent. In the case of the pre separation procedure using solid reversed phase column, the palladium was retained using N,N-diethyl-N’-benzoyl thiourea complexant and eluted using ethanol. Aliquots of the resulting solutions from the pre-separations, free of interfering elements, were transfered to polyethylene capsules and analyzed by ENAA. Comparisons of palladium results obtained using different procedures of neutron activations analysis showed good agreement and precision. The relative standard deviations of palladium results varied between 2 and 14 %. The recovery yields obtained in the pre-separation procedure varied from 70.9 to 97.7 %, depending on the matrices analyzed and method of separation. Detection limits of 11.0 and 0.4 μg g-1 were obtained in the Pd determination in bovine muscle samples by INAA and ENAA, respectively. For reference material BCR- 723 road dust detection limits of 24.0 and 1.7 μg g-1 were obtained by INAA and ENAA, respectively. These results indicated that the detection limit depends on the matrix type to be analyzed and the epithermal neutron activation allowed high sensitivity for Pd determination due to the reduction of interferences. In regards to palladium determination using pre-separation procedures, the detection limit values indicated that the extraction procedure provides higher sensitivity, when compared to purely instrumental ENAA.
12

Detecção do vírus da cinomose pela técnica de RT-PCR em cães com sintomatologia neurológica / Detection of canine distemper virus by RT- PCR from dogs with neurological signs

Helena Arantes do Amaral 29 August 2007 (has links)
Diferentes amostras biológicas foram avaliadas (zaragatoa ocular, genital, urina e células mononucleares do sangue periférico) pela RT-PCR em 50 cães com sintomas neurológicos compatíveis como cinomose, na presença ou não de outros sintomas sistêmicos. O gene da nucleoproteína do vírus da cinomose foi detectado em 43 das 50 amostras avaliadas. Considerando apenas os animais com resultado positivos pela hemi-nested - PCR, os sintomas neurológicos observados com freqüência maior que 50%, foram mioclonia e alteração locomotora (maioria dos cães evoluiu a tetraparesia); convulsão e vocalização foram observados em 32% dos casos Outros sintomas sistêmicos, sintomas oculares, respiratórios ou digestivos, prévios ou associados aos sintomas neurológicos, foram observados em 82% dos cães. Também observou-se hiperqueratose nasal ou de coxins em 44% dos casos. Somente 20% dos animais positivos haviam sido vacinados contra o vírus da cinomose. Zaragatoas genitais forneceram maior número de resultados positivos (40), seguidos por zaragatoas oculares e urina (37) e células mononucleares do sangue periférico (34). A coleta associada de duas amostras biológicas (zaragatoa genital e urina) por animal aumentou a possibilidade de detecção de animais positivos, principalmente nos casos de cães suspeitos que não apresentaram sintomas respiratórios, gastrintestinais e oculares, assim como nos animais vacinados e cronicamente infectados ou convalescentes. / Using Reverse transcription-PCR assay, different biological samples were avaliabled (conjunctival and genital swabs, urine and peripheral blood mononuclear cells) from dogs with or with no extraneural signs prior to or accompanying the neurologic signs. Canine distemper nucleoprotein were detected in 43 from 50 dogs availabled by hemi-nested-PCR. Considering just dogs with distemper confirmed by hemi-nested PCR, gait abnormalities (most commonly tetraparesis) and myoclonus were the neurological signs observed in over 50%; vocalizing and seizures occurred in 32%. Other systemic signs (respiratory, gastroenteric or ocular signs). preceding or associated to neurological signs, occurred in 82% of dogs Hyperkeratosis of the footpads or nose were observed in 44 % of the cases. Only (20%) were vaccinated against canine distemper. A greater number of positive results were obtained from genital swabs (40), followed by conjuctival swabs and urine (37) and PBMCs (33). Sensitivity of detection positive results were increased by using two clinical samples association (genital swab and urine), specially in dogs that had not shown extra neural signs, vaccinate dogs or during the convalescent and late stage of canine distemper.
13

Determinação de elementos essenciais e contaminantes em amostras biológicas empregando espectrometria atômica

Santos, Luiz Raimundo Seneterri Silva Rodrigues dos January 2010 (has links)
Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2016-09-06T15:11:17Z No. of bitstreams: 1 DISSERTAÇÃO LUIZ RAIMUNDO S.S.R.SANTOS.pdf: 1266644 bytes, checksum: 450e692c86f2ffc5bc25ffa7e76b9e3d (MD5) / Approved for entry into archive by Vanessa Reis (vanessa.jamile@ufba.br) on 2016-09-06T15:37:29Z (GMT) No. of bitstreams: 1 DISSERTAÇÃO LUIZ RAIMUNDO S.S.R.SANTOS.pdf: 1266644 bytes, checksum: 450e692c86f2ffc5bc25ffa7e76b9e3d (MD5) / Made available in DSpace on 2016-09-06T15:37:29Z (GMT). No. of bitstreams: 1 DISSERTAÇÃO LUIZ RAIMUNDO S.S.R.SANTOS.pdf: 1266644 bytes, checksum: 450e692c86f2ffc5bc25ffa7e76b9e3d (MD5) / O estudo de elementos essenciais e contaminantes nas amostras biológicas é de grande importância visto que a variação da concentração destes é um parâmetro para detecção de diversas doenças e distúrbios metabólicos provocados pela exposição a substâncias tóxicas e medicamentos. O objetivo deste trabalho foi propor um método analítico visando avaliar o efeito da furosemida (diurético de alça) sobre a composição mineral (Mg, Cu, Fe, Se, Zn, Cd e Pb) em amostras biológicas (fígado, rim, coração, pulmão e soro) de ratos Wistar por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES). Para a decomposição das amostras foi utilizado um procedimento por via úmida, com adição de ácido nítrico e peróxido de hidrogênio, empregando forno de microondas com cavidade. As figuras analíticas de mérito (precisão, limites de detecção (LOD) e quantificação (LOQ) e efeito de matriz) foram determinadas para o procedimento proposto. A exatidão foi verificada com material de referência certificado fígado bovino NIST 1577b e por comparação com método de referência da AOAC (Association of Official Analytical Chemists). O procedimento proposto foi aplicado para avaliação dos efeitos da furosemida sobre a composição corporal de elementos essenciais e contaminantes de ratos Wistar. Os dados para Se, Cd e Pb foram abaixo do LOQ, sendo necessário a utilização de técnicas mais sensíveis como GF AAS e ICP-MS para a quantificação desses elementos em amostras biológicas. Em relação ao comportamento dos minerais nas amostras biológicas estudadas, o Cu, nas amostras biológicas dos ratos machos, este apresenta uma redução no fígado, rim e coração, mantendo-se constante no pulmão. Nas fêmeas há um aumento no fígado e redução no rim, coração e pulmão. Para o Fe, o comportamento é semelhante entre machos e fêmeas, com redução no fígado, rim e soro e aumento no coração e pulmão. O Mg apresenta uma constância no fígado e pulmão, redução no rim, coração e aumento no soro para machos, enquanto para fêmeas, em fígado e rim permanecem constantes e há redução no coração, pulmão e soro. Já o Zn reduz no fígado e rim dos machos e se mantém constante no coração e pulmão, sendo o inverso para as fêmeas. Foi encontrando como resultados uma extração dos elementos Mg, Cu e Zn em todos os tecidos biológicos estudados em uma magnitude de 16,8; 15,1 e 6,4 % para ratos machos e 13,0; 16,5 e 8,1 % para fêmeas, após a administração da furosemida em todos os animais estudados. O Fe apresentou um aumento de 21,8% e 5,1%, em todos os tecidos biológicos estudados, para ratos machos e fêmeas respectivamente, concluindo que a furosemida não traz prejuízos para a saúde com relação à perda de elementos essenciais / The study of essential elements and contaminants in biological samples is of great importance since the variation of the concentration of these is a parameter for the detection of various diseases and metabolic disorders caused by exposure to toxic substances and medicines. The aim of this study was to propose an analytical method to evaluate the effect of furosemide (loop diuretic) on the mineral composition (Mg, Cu, Fe, Se, Zn, Cd and Pb) in biological samples (liver, kidney, heart, lung and serum) of rats by optical emission spectrometry with inductively coupled plasma (ICP OES). For decomposition of the samples we used a procedure by wet, with the addition of nitric acid and hydrogen peroxide, using a microwave cavity. The analytical figures of merit (precision, limit of detection (LOD) and quantification (LOQ) and matrix effect) were determined for the proposed procedure. The accuracy was checked with certified reference material NIST 1577b bovine liver and by comparison with reference method AOAC (Association of Official Analytical Chemists). The proposed procedure was applied to assess the effects of furosemide on body composition of essential elements and contaminants in rats. The data for Se, Cd and Pb were below the LOQ, necessitating the use of more sensitive techniques such as GF AAS and ICP-MS for quantification of these elements in biological samples. As for the behavior of minerals in biological samples studied, the Cu in biological samples from male rats, this presents a reduction in the liver, kidney and heart, remaining constant in the lung. In females there is an increase in the liver and reduction in kidney, heart and lung. For Fe, the behavior is similar between males and females, with a reduction in the liver, kidney and serum and increased heart and lung. Magnesium has a constancy in the liver and lung, reduction in kidney, heart and an increase in serum for males as for females, liver and kidney remain constant and there is a reduction in heart, lung and serum. Already reduces the Zn in the liver and kidney of males and remained constant in the heart and lungs, and the converse for females. Was found as a result of the extraction elements Mg, Cu and Zn in all biological tissues studied in a magnitude of 16.8, 15.1 and 6.4% for males and 13.0, 16.5 and 8.1 % for females, after administration of furosemide in all animals studied. Fe showed an increase of 21.8% and 5.1% in all biological tissues studied, for males and females respectively, concluding that furosemide does not bring harm to health in relation to loss of essential elements
14

Avaliação de diferentes cronogramas de coletas de amostras biológicas em estudos de bioequivalência e análise da influência de teor de fármaco sobre os resultados destes estudos / Evaluation of the effects on different doses and sampling schedules on the assessment of bioequivalence

Kano, Eunice Kazue 25 March 2008 (has links)
Os estudos de bioequivalência são realizados em humanos, por meio da administração dos medicamentos em estudo pela mesma via extravascular, sob condições experimentais padronizadas, seguida pela determinação das concentrações plasmáticas do fármaco em função do tempo. Nestes estudos considera-se que curvas estatisticamente semelhantes de decaimento sanguíneo de fármacos produzem o mesmo resultado em termos de eficácia e segurança. A partir das curvas de concentração em função do tempo obtidas, determinam-se os parâmetros farmacocinéticos Cmax, tmax e ASC. A bioequivalência entre dois produtos é estabelecida por meio do IC 90%, que deve estar entre 80 a 125% para os parâmetros farmacocinéticos Cmax e ASC. O cronograma de coleta de amostras biológicas é um dos aspectos mais críticos no planejamento de estudos de bioequivalência, pois este afeta diretamente a determinação dos parâmetros farmacocinéticos utilizados na avaliação da bioequivalência. Outro aspecto importante relacionado a este tipo de estudo é a diferença de teor entre os produtos a serem submetidos ao estudo de bioequivalência, que segundo a legislação brasileira vigente, deve ser menor ou igual a 5%. Neste trabalho foram avaliados diferentes cronogramas de coleta de amostras sangue, avaliando-se o impacto destes no resultado final de um estudo de bioequivalência e, além disso, a influência da diferença de teor de fármaco entre dois produtos que levaria à bioinequivalência também foi investigada. Para tanto simulações matemáticas e um estudo in vivo foram conduzidos. O fármaco modelo escolhido foi a cefadroxila, por apresentar características farmacocinéticas e farmacodinâmicas ideais. O programa Microsoft Office Excel 2003 foi utilizado para simular as concentrações plasmáticas e determinar o IC 90%. As simulações foram feitas por meio de dois modelos: modelo baseado em máximos e mínimos de parâmetros farmacocinéticos, e modelo baseado em coeficientes de variação intra e inter-individuais do fármaco. Dez diferentes doses, entre -10% a 20% da dose referência, e 6 cronogramas de coleta foram avaliados. O estudo in vivo foi realizado com quatro doses diferentes de cefadroxila. A bioequivalência entre as doses e em diferentes cronogramas de coleta foi avaliada em 24 voluntários sadios do sexo masculino. Os voluntários receberam as quatro doses do estudo em desenho cruzado, em quatro períodos e quatro seqüências, com washout de 7 dias entre as doses. As concentrações plasmáticas de cefadroxila, até 8 horas após a administração, foram determinadas por cromatografia líquida de alta eficiência com detecção DAD. Os parâmetros farmacocinéticos tmax, Cmax e AUC0-t foram determinados nas diferentes doses e cronogramas de coleta, sendo que o critério para estabelecer-se a bioequivalência foi baseada nos resultados do IC 90% dos parâmetros farmacocinéticos Cmax e AUC0-t. Os resultados obtidos nas simulações mostraram boa correlação com os dados reais obtidos a partir de estudos in vivo. As simulações baseadas em coeficientes de variação intra e inter-individuais descreveram melhor os resultados observados no estudo in vivo. De acordo com os resultados obtidos no estudo in vivo pode-se concluir que cronogramas de coletas com menos amostras são tão eficientes quanto cronogramas de coletas com mais amostras, desde que o tempo de tmax esteja incluído. Em relação ao teor de fármaco, concluiu-se que dois produtos com diferença de teor menor ou igual a 11% ainda são bioequivalentes e que diferença maior ou igual a 14% resultam em bioinequivalência. Observou-se ainda que o parâmetro farmacocinético ASC0-t é mais sensível que Cmax para detectar diferenças. / Bioequivalence studies are designed to compare the in vivo performance of different formulations of the same drug or different drug products by a randomized crossover study. Pharmacokinetic parameters are obtained from the drug concentration-time profile in blood, serum, or plasma. The most frequently used pharmacokinetic parameters are area under the plasma or blood concentration-time curve (AUC), maximum concentration (Cmax) and time to achieve maximum concentration (tmax). Bioequivalence is concluded if the average bioavailability of the test formulation is within (80%, 125%) that of the reference formulation, with a certain assurance, that is, an equivalence criterion of 80% to 125% for assessment of bioequivalence based on the ratio of average bioavailability is employed. The logarithmic transformation is used for AUC and Cmax. Accuracy in measuring pharmacokinetics parameters directly affects accuracy of bioequivalence tests. Since the number of blood samples per patient is limited, sampling points should be chosen such that the time concentration profile is adequately defined so as to allow the calculation of relevant parameters. According to guidelines proposed by the National Agency of Sanitary Vigilance of Brazil (ANVISA), bioequivalence studies can be conducted only if the difference in drug content between the reference and test product is less than or equal to 5%. The goals of this study are to evaluate the influence of differences in amount of active moiety present in the formulation and possibility of reducing the number of sampling points in bioequivalence studies and to discuss the impact of these parameters in bioequivalence conclusions. For these approaches, simulations and an in vivo study were done. The drug selected was cefadroxil. Cefadroxil presents ideal pharmacokinetics and pharmacodynamics characteristics for this kind of study, such as high bioavailability, low intra and intersubject variability, short elimination rate and wide therapeutic range. Microsoft Office Excel 2003 software was used to simulate drug concentration-time profiles for different doses and several sampling schedules, and to determine 90% confidence interval. Simulations were done by two models: a) based on assumed maximum and minimum pharmacokinetic parameters values; b) based on assumed intra and intersubject variability. Ten different doses, ranging from -10% to 20% of the reference dose, and six sampling schedules were evaluated. The in vivo study was performed with four different cefadroxil doses. Their relative bioavailability were evaluated in 24 healthy volunteers who received a single oral dose of each preparation. An open, randomized clinical trial designed as four-periods and four sequences crossover with 7-days washout between doses was employed. Plasma samples for assessments of their cefadroxil concentration by HPLC-DAD were obtained over 8 h after administration. Pharmacokinetics parameters tmax, Cmax and AUC0-t were evaluated using different doses and sampling schedules. For the purpose of bioequivalence analysis Cmax and AUC0-t were considered. For each schedule, to claim bioequivalence in average bioavailability, a 90% confidence interval was constructed for ratio of average between test and reference products and compared with (80%, 125%) limits. If the constructed confidence interval falls within the limits, then the two formulations are considered bioequivalent. The results obtained by simulate time-concentration profiles, showed good correlation with real data. Comparing the results obtained through in vivo study and the two simulations models, the simulations based in intra and intersubject variability was more predictive. In conclusion, no significant differences were found between sampling schedules evaluated, since the sampling time around tmax were maintained in sampling schedules. Bioinequivalence was observed when the difference between cefadroxil doses was higher than 14%. The parameter AUC0-t was more sensitive than Cmax to detect differences.
15

Desenvolvimento de métodos espectrofotométricos em condições estacionária e em fluxo para determinação de zinco em amostras biológicas e farmacêuticas / Development of stationary and flow spectrophotometric methods for the determination of zinc in biological and pharmaceutical samples

Ivanise Gaubeur 29 June 2001 (has links)
Métodos espectrofotométricos em condições estacionária e em fluxo para determinação de Zn(II) foram desenvolvidos com base na formação do complexo de Zn(II) com di-2-piridil cetona saliciloilhidrazona (DPKSH), em meio de etanol-água 50% (V/V) e pH 4,5. Os complexos de Zn(II) com DPKSH foram caracterizados utilizando diferentes técnicas e as respectivas constantes de formação (βl 1,07x105 e β2 1,05x1010) e absortividades molares, em 376 nm, (εl 1,1x104 e ε2 4,5x104) determinadas. Os parâmetros para o método em condição estacionária foram otimizados e, a seguir, construiu-se a respectiva curva analítica. Obteve-se uma faixa de linearidade (lei de Beer) de (0,0293 a 2,01)x10-5mol. L-1, absortividade molar média (em 376 nm, em meio de etanol-água 50% (V/V) e pH 4,5) de 4,83x104 mol-1.L.cm-1 e limite de detecção igual a 1,24x10-7 mol.L-1 (8,11 µg.L-1). Avaliou-se a interferência de 43 íons. Alguns destes que apresentaram interferência positiva são comuns em preparações farmacêuticas e amostras biológicas, porém tal interferência pode ser facilmente eliminada. Aplicou-se o método desenvolvido à preparações farmacêuticas e amostras biológicas. Comparando-se os resultados com a técnica de absorção atômica com chama, obteve-se grande concordância. O método espectrofotométrico em fluxo foi desenvolvido a partir de alguns parâmetros previamente estudados e estabelecidos. Construiu-se a curva analítica e obteve-se uma faixa de linearidade de (0,332 a 7,04)x 10-5 mol.L-1 e limite de detecção 7,46x10-7 mol.L-1 (48,8 µg.L-1). Aplicou-se o método em preparações farmacêuticas e comparando-se os resultados com a técnica de absorção atômica com chama observou-se grande concordância. Com a finalidade de aplicar o método em fluxo a amostras biológicas, foi acoplada ao sistema uma coluna com resina de troca iônica no lugar da alça de amostragem. Após avaliar alguns parâmetros, construiu-se a curva analítica que apresentou uma faixa de linearidade de (0,126 a 3,15)x10-5 mol.L-1 e limite de detecção 2,12x10-7 mol.L-1 (13,9 µg.L-1). / Spectrophotometric methods in stationary and flow conditions were developed for Zn(II) determination based on the complex formation of Zn(II) with di-2-pyridyl ketone salicyloylhydrazona (DPKSH), in ethanol-water 50% (V/V) medium and pH 4.5. The complexes Zn(II)/DPKSH were characterized by several methods and the respective formation constants (β1 1.07x105 and β2 1.05x1010) and molar absorptivities, in 376 nm, (ε1 1.1x104 and ε2 4.5x104) were determinated. Parameters for the stationary method were optimized and, the analytical curve was obtained. A linear behavior (Beer\'s law) was verified in the range (0.0293 and 2.01)x10-5mol.L-1, the medium molar absorptivity (in 376 nm, ethanol-water 50% (V/V) medium and pH 4.5) and the detection limit are 4.83x104 mol-1.L.cm-1 and 1.24x10-7 mol.L-1 (8.11 ppb), respectively. The interference of 43 ions was evaluated. Some of them that showed present a positive interference are commom in pharmaceutical formulations and biological samples, but such interference could be easily eliminated. The developed method was applied to pharmaceutical formulations and biological samples. The results complied well with atomic absorption (flame atomization) technique. A spectrophotometric method in flow was developed upon some previously established parameters. The analytical curve was determined and a linear range was verified between (0.332 to 7.04)x10-5 mol.L-1, and the detection limit 7.46x10-7 mol.L-1 ( 48.8 µg.L-1). This method was applied to pharmaceutical formulations and the results showed a good agreement with atomic absorption (flame atomization) technique. Aiming at employing the flow method to biological samples an ion-exchange resin column was adapted substituting the sampling handle. After evaluating some parameters the analytical curve was determined and it displayed a linear range of (0.126 to 3.15)x10-5 mol.L-1, and detection limit 2.12x10-7 mol.L-1 (13.9 µg.L-1).
16

Avaliação de diferentes cronogramas de coletas de amostras biológicas em estudos de bioequivalência e análise da influência de teor de fármaco sobre os resultados destes estudos / Evaluation of the effects on different doses and sampling schedules on the assessment of bioequivalence

Eunice Kazue Kano 25 March 2008 (has links)
Os estudos de bioequivalência são realizados em humanos, por meio da administração dos medicamentos em estudo pela mesma via extravascular, sob condições experimentais padronizadas, seguida pela determinação das concentrações plasmáticas do fármaco em função do tempo. Nestes estudos considera-se que curvas estatisticamente semelhantes de decaimento sanguíneo de fármacos produzem o mesmo resultado em termos de eficácia e segurança. A partir das curvas de concentração em função do tempo obtidas, determinam-se os parâmetros farmacocinéticos Cmax, tmax e ASC. A bioequivalência entre dois produtos é estabelecida por meio do IC 90%, que deve estar entre 80 a 125% para os parâmetros farmacocinéticos Cmax e ASC. O cronograma de coleta de amostras biológicas é um dos aspectos mais críticos no planejamento de estudos de bioequivalência, pois este afeta diretamente a determinação dos parâmetros farmacocinéticos utilizados na avaliação da bioequivalência. Outro aspecto importante relacionado a este tipo de estudo é a diferença de teor entre os produtos a serem submetidos ao estudo de bioequivalência, que segundo a legislação brasileira vigente, deve ser menor ou igual a 5%. Neste trabalho foram avaliados diferentes cronogramas de coleta de amostras sangue, avaliando-se o impacto destes no resultado final de um estudo de bioequivalência e, além disso, a influência da diferença de teor de fármaco entre dois produtos que levaria à bioinequivalência também foi investigada. Para tanto simulações matemáticas e um estudo in vivo foram conduzidos. O fármaco modelo escolhido foi a cefadroxila, por apresentar características farmacocinéticas e farmacodinâmicas ideais. O programa Microsoft Office Excel 2003 foi utilizado para simular as concentrações plasmáticas e determinar o IC 90%. As simulações foram feitas por meio de dois modelos: modelo baseado em máximos e mínimos de parâmetros farmacocinéticos, e modelo baseado em coeficientes de variação intra e inter-individuais do fármaco. Dez diferentes doses, entre -10% a 20% da dose referência, e 6 cronogramas de coleta foram avaliados. O estudo in vivo foi realizado com quatro doses diferentes de cefadroxila. A bioequivalência entre as doses e em diferentes cronogramas de coleta foi avaliada em 24 voluntários sadios do sexo masculino. Os voluntários receberam as quatro doses do estudo em desenho cruzado, em quatro períodos e quatro seqüências, com washout de 7 dias entre as doses. As concentrações plasmáticas de cefadroxila, até 8 horas após a administração, foram determinadas por cromatografia líquida de alta eficiência com detecção DAD. Os parâmetros farmacocinéticos tmax, Cmax e AUC0-t foram determinados nas diferentes doses e cronogramas de coleta, sendo que o critério para estabelecer-se a bioequivalência foi baseada nos resultados do IC 90% dos parâmetros farmacocinéticos Cmax e AUC0-t. Os resultados obtidos nas simulações mostraram boa correlação com os dados reais obtidos a partir de estudos in vivo. As simulações baseadas em coeficientes de variação intra e inter-individuais descreveram melhor os resultados observados no estudo in vivo. De acordo com os resultados obtidos no estudo in vivo pode-se concluir que cronogramas de coletas com menos amostras são tão eficientes quanto cronogramas de coletas com mais amostras, desde que o tempo de tmax esteja incluído. Em relação ao teor de fármaco, concluiu-se que dois produtos com diferença de teor menor ou igual a 11% ainda são bioequivalentes e que diferença maior ou igual a 14% resultam em bioinequivalência. Observou-se ainda que o parâmetro farmacocinético ASC0-t é mais sensível que Cmax para detectar diferenças. / Bioequivalence studies are designed to compare the in vivo performance of different formulations of the same drug or different drug products by a randomized crossover study. Pharmacokinetic parameters are obtained from the drug concentration-time profile in blood, serum, or plasma. The most frequently used pharmacokinetic parameters are area under the plasma or blood concentration-time curve (AUC), maximum concentration (Cmax) and time to achieve maximum concentration (tmax). Bioequivalence is concluded if the average bioavailability of the test formulation is within (80%, 125%) that of the reference formulation, with a certain assurance, that is, an equivalence criterion of 80% to 125% for assessment of bioequivalence based on the ratio of average bioavailability is employed. The logarithmic transformation is used for AUC and Cmax. Accuracy in measuring pharmacokinetics parameters directly affects accuracy of bioequivalence tests. Since the number of blood samples per patient is limited, sampling points should be chosen such that the time concentration profile is adequately defined so as to allow the calculation of relevant parameters. According to guidelines proposed by the National Agency of Sanitary Vigilance of Brazil (ANVISA), bioequivalence studies can be conducted only if the difference in drug content between the reference and test product is less than or equal to 5%. The goals of this study are to evaluate the influence of differences in amount of active moiety present in the formulation and possibility of reducing the number of sampling points in bioequivalence studies and to discuss the impact of these parameters in bioequivalence conclusions. For these approaches, simulations and an in vivo study were done. The drug selected was cefadroxil. Cefadroxil presents ideal pharmacokinetics and pharmacodynamics characteristics for this kind of study, such as high bioavailability, low intra and intersubject variability, short elimination rate and wide therapeutic range. Microsoft Office Excel 2003 software was used to simulate drug concentration-time profiles for different doses and several sampling schedules, and to determine 90% confidence interval. Simulations were done by two models: a) based on assumed maximum and minimum pharmacokinetic parameters values; b) based on assumed intra and intersubject variability. Ten different doses, ranging from -10% to 20% of the reference dose, and six sampling schedules were evaluated. The in vivo study was performed with four different cefadroxil doses. Their relative bioavailability were evaluated in 24 healthy volunteers who received a single oral dose of each preparation. An open, randomized clinical trial designed as four-periods and four sequences crossover with 7-days washout between doses was employed. Plasma samples for assessments of their cefadroxil concentration by HPLC-DAD were obtained over 8 h after administration. Pharmacokinetics parameters tmax, Cmax and AUC0-t were evaluated using different doses and sampling schedules. For the purpose of bioequivalence analysis Cmax and AUC0-t were considered. For each schedule, to claim bioequivalence in average bioavailability, a 90% confidence interval was constructed for ratio of average between test and reference products and compared with (80%, 125%) limits. If the constructed confidence interval falls within the limits, then the two formulations are considered bioequivalent. The results obtained by simulate time-concentration profiles, showed good correlation with real data. Comparing the results obtained through in vivo study and the two simulations models, the simulations based in intra and intersubject variability was more predictive. In conclusion, no significant differences were found between sampling schedules evaluated, since the sampling time around tmax were maintained in sampling schedules. Bioinequivalence was observed when the difference between cefadroxil doses was higher than 14%. The parameter AUC0-t was more sensitive than Cmax to detect differences.
17

Desenvolvimento de métodos espectrofotométricos em condições estacionária e em fluxo para determinação de zinco em amostras biológicas e farmacêuticas / Development of stationary and flow spectrophotometric methods for the determination of zinc in biological and pharmaceutical samples

Gaubeur, Ivanise 29 June 2001 (has links)
Métodos espectrofotométricos em condições estacionária e em fluxo para determinação de Zn(II) foram desenvolvidos com base na formação do complexo de Zn(II) com di-2-piridil cetona saliciloilhidrazona (DPKSH), em meio de etanol-água 50% (V/V) e pH 4,5. Os complexos de Zn(II) com DPKSH foram caracterizados utilizando diferentes técnicas e as respectivas constantes de formação (βl 1,07x105 e β2 1,05x1010) e absortividades molares, em 376 nm, (εl 1,1x104 e ε2 4,5x104) determinadas. Os parâmetros para o método em condição estacionária foram otimizados e, a seguir, construiu-se a respectiva curva analítica. Obteve-se uma faixa de linearidade (lei de Beer) de (0,0293 a 2,01)x10-5mol. L-1, absortividade molar média (em 376 nm, em meio de etanol-água 50% (V/V) e pH 4,5) de 4,83x104 mol-1.L.cm-1 e limite de detecção igual a 1,24x10-7 mol.L-1 (8,11 µg.L-1). Avaliou-se a interferência de 43 íons. Alguns destes que apresentaram interferência positiva são comuns em preparações farmacêuticas e amostras biológicas, porém tal interferência pode ser facilmente eliminada. Aplicou-se o método desenvolvido à preparações farmacêuticas e amostras biológicas. Comparando-se os resultados com a técnica de absorção atômica com chama, obteve-se grande concordância. O método espectrofotométrico em fluxo foi desenvolvido a partir de alguns parâmetros previamente estudados e estabelecidos. Construiu-se a curva analítica e obteve-se uma faixa de linearidade de (0,332 a 7,04)x 10-5 mol.L-1 e limite de detecção 7,46x10-7 mol.L-1 (48,8 µg.L-1). Aplicou-se o método em preparações farmacêuticas e comparando-se os resultados com a técnica de absorção atômica com chama observou-se grande concordância. Com a finalidade de aplicar o método em fluxo a amostras biológicas, foi acoplada ao sistema uma coluna com resina de troca iônica no lugar da alça de amostragem. Após avaliar alguns parâmetros, construiu-se a curva analítica que apresentou uma faixa de linearidade de (0,126 a 3,15)x10-5 mol.L-1 e limite de detecção 2,12x10-7 mol.L-1 (13,9 µg.L-1). / Spectrophotometric methods in stationary and flow conditions were developed for Zn(II) determination based on the complex formation of Zn(II) with di-2-pyridyl ketone salicyloylhydrazona (DPKSH), in ethanol-water 50% (V/V) medium and pH 4.5. The complexes Zn(II)/DPKSH were characterized by several methods and the respective formation constants (β1 1.07x105 and β2 1.05x1010) and molar absorptivities, in 376 nm, (ε1 1.1x104 and ε2 4.5x104) were determinated. Parameters for the stationary method were optimized and, the analytical curve was obtained. A linear behavior (Beer\'s law) was verified in the range (0.0293 and 2.01)x10-5mol.L-1, the medium molar absorptivity (in 376 nm, ethanol-water 50% (V/V) medium and pH 4.5) and the detection limit are 4.83x104 mol-1.L.cm-1 and 1.24x10-7 mol.L-1 (8.11 ppb), respectively. The interference of 43 ions was evaluated. Some of them that showed present a positive interference are commom in pharmaceutical formulations and biological samples, but such interference could be easily eliminated. The developed method was applied to pharmaceutical formulations and biological samples. The results complied well with atomic absorption (flame atomization) technique. A spectrophotometric method in flow was developed upon some previously established parameters. The analytical curve was determined and a linear range was verified between (0.332 to 7.04)x10-5 mol.L-1, and the detection limit 7.46x10-7 mol.L-1 ( 48.8 µg.L-1). This method was applied to pharmaceutical formulations and the results showed a good agreement with atomic absorption (flame atomization) technique. Aiming at employing the flow method to biological samples an ion-exchange resin column was adapted substituting the sampling handle. After evaluating some parameters the analytical curve was determined and it displayed a linear range of (0.126 to 3.15)x10-5 mol.L-1, and detection limit 2.12x10-7 mol.L-1 (13.9 µg.L-1).

Page generated in 0.0927 seconds