• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • Tagged with
  • 8
  • 8
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Historico, usos oficiais e avaliação da redução de escala de analise volumetrica para fins didaticos

Terra, Juliana 03 August 2018 (has links)
Orientador : Adriana Vitorino Rossi / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-03T22:54:39Z (GMT). No. of bitstreams: 1 Terra_Juliana_M.pdf: 7429666 bytes, checksum: f1a1c7787e52d033ff58c12285224c98 (MD5) Previous issue date: 2004 / Resumo: Os métodos ditos clássicos representaram um papel fundamental no desenvolvimento da Química. Durante os séculos XVIII e XIX eram praticamente os únicos processos usados nas análises químicas e hoje, mesmo com o desenvolvimento tecnológico, têm sua presença constante. Depois de realizada uma extensa pesquisa bibliográfica, apresenta-se uma descrição do desenvolvimento da volumetria que permite contextualizar importantes aspectos científicos de relevância para abordagens didáticas de diferentes conceitos químicos e aspectos históricos de 1729 a 2000. Dados informativos atuais incluíram a verificação da aplicabilidade da volumetria, mediante uma cuidadosa consulta a obras de referência (mais detalhadamente, American Organization of Analytical Chemists - AOAC) para um levantamento dos métodos oficiais de análise vigentes que envolvem volumetria. Foi possível notar que cerca de 17% do total de métodos da AOAC ainda envolvem volumetria para as mais diferentes análises. Considerando o elevado potencial didático representado pelas experiências envolvendo titulações, foi avaliada a proposta para redução de escala das análises volumétricas mais comumente empregadas em atividades de ensino de Química Analítica no nível superior, visando a redução do consumo de reagentes e, principalmente, de resíduos gerados sem comprometer figuras de mérito analítico. Aspectos relacionados a custos e à eficiência pedagógica da proposta foram observados e discutidos num contexto de inserção da volumetria como objeto de estudo em cursos superiores / Abstract: Classical methods of analysis played a fundamental role in the development of Chemistry and the Chemical Industry. During the XVIII and XIX centuries they were the only processes used in the chemical analysis. Today, with technological development, they are still applied. After an extensive bibliographic search, a description of the development of the titrimetry is presented and shows important scientific aspects of relevance for a didactic approach to different chemical concepts and historical landmarks from 1729 to 2000. Current informative data includes verification of the applicability of titrimetry, by means of a careful consultation of reference books (more detailed in the American Organization of Analytical Chemists - AOAC) to prepare a list of the effective presence of the titrimetry in today's official methods of analysis. About 17 % of the total of methods of the AOAC still involve titrimetry for the most different types of analysis. Considering the didactic potential represented by the experiments involving titrimetry, a proposal for reduction of scale of the most common volumetric analyses taught in undergraduate Analytical Chemistry classes was evaluated, in order to reduce the consumption of reagents and the generation of residues, without compromising analytical performance. Aspects related to the costs and the pedagogical efficiency of the proposal have been obtained and are presented in the context of insertion of titrimetry as a subject for study in undergraduate courses / Mestrado
2

Aplicação da titulação termometrica na determinação da "acidez total" e substancias polifenolicas "em vinhos"

Coelho, Jose Augusto 15 July 2018 (has links)
Orientador : Oswaldo E. S. Godinho / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-15T03:45:51Z (GMT). No. of bitstreams: 1 Coelho_JoseAugusto_M.pdf: 3615279 bytes, checksum: 499ce07a4965bf9dc76190c39571defb (MD5) Previous issue date: 1981 / Mestrado
3

Taliscas de bambu em matrizes de concreto : caracteristicas fisico-mecanicas

Argollo Ferrão, André Munhoz de, 1965- 15 December 1992 (has links)
Orientador : Wesley Jorge Freire / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-07-18T11:39:56Z (GMT). No. of bitstreams: 1 ArgolloFerrao_AndreMunhozde_M.pdf: 3513941 bytes, checksum: aed159571f6e512ada084bfbc43052e6 (MD5) Previous issue date: 1992 / Mestrado / Mestre em Engenharia Agrícola
4

Estudo experimental e modelagem do volume em excesso para sistemas do tipo água / alcanodiol / líquido iônico à pressão ambiente e temperatura de 298,15 K / Experimental study and modeling of the excess volume for systems of type water / alcanediol / ionic liquid at ambient pressure and temperature of 298.15 K

Rodrigues, Marcelo 18 August 2018 (has links)
Orientador: Artur Zaghini Francesconi / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Química / Made available in DSpace on 2018-08-18T11:18:21Z (GMT). No. of bitstreams: 1 Rodrigues_Marcelo_M.pdf: 1028536 bytes, checksum: 23f02a0880e6d6900107ba391cfe6c73 (MD5) Previous issue date: 2011 / Resumo: Nesta dissertação foi estudado o comportamento do volume em excesso em relação à composição de sistemas contendo água, alcanodióis e um líquido iônico a 298,15 K. Os dados experimentais foram obtidos pelo método indireto utilizando-se a densitometria por oscilação mecânica. Os alcanodióis utilizados nos sistemas estudados foram o 1,2-etanodiol, o 1,2-propanodiol, 1,2-butanodiol e o 1,3-propanodiol. O líquido iônico utilizado para o experimento foi o brometo de 1-butil-3-metilimidazólio. A fração molar do líquido iônico foi de 0,01 para todos os experimentos. Os valores de VmE foram correlacionados utilizando-se um polinômio do tipo Redlich-Kister. Os dados experimentais sem o líquido iônico foram correlacionados pelo modelo ERAS e PFP. Os dados experimentais do sistema água / alcanodiol / líquido iônico foram correlacionados utilizando-se o modelo ERAS e PFP modificados com a adição da equação de Hepler relativo a um termo de efeito salino / Abstract: In this work it was studied the behavior of the excess volume in relation to composition of systems with water, alkanediols and an ionic liquid at 298.15 K. The experimental data were acquired from an indirect method by means of vibrating-tube densimeter (Anton Paar, DMA 55). Alkanediols used in this work were 1,2-ethanediol, 1,2-propanediol, 1,2-butanediol and 1,3-propanediol. 1-n-butyl-3-methylimidazolium bromide was the ionic liquid used in this experiment. The ionic liquid was 0.01 of mole fraction for all experiments. The VmE data were correlated with a Redlich-Kister type polynomial. Experimental data from water + alkanediol system were correlated with ERAS and PFP model. Water + alkanediol + ionic liquid system were correlated using an ERAS and PFP modified with a Hepler equation related to a salt effect term / Mestrado / Sistemas de Processos Quimicos e Informatica / Mestre em Engenharia Química
5

Manipulação gravimetrica automatica de soluções

Cunha, Ildenize B. S 19 July 2018 (has links)
Orientador : Celio Pasquini / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-19T09:32:16Z (GMT). No. of bitstreams: 1 Cunha_IldenizeB.S_D.pdf: 5906129 bytes, checksum: 0f1152ff9ea91e411c561d088124cbfb (MD5) Previous issue date: 1994 / Doutorado
6

Avaliação volumétrica de defeitos ósseos em fissuras de rebordo alveolar e palato duro por meio da 3D-TC multislice e feixe cônico / Volumetric assessment of hard palate and alveolar cleft using multislice and cone beam 3DCT

Albuquerque, Marco Antonio Portela 11 November 2010 (has links)
As fissuras de rebordo alveolar e palato duro estão entre as malformações mais frequentes do corpo humano, podendo causar extensas deformidades ósseas faciais, com implicações biopsíquico-sociais marcantes. A avaliação da extensão desses defeitos ósseos, através de exames por imagem, tem sido feita com o objetivo de diagnosticar e planejar a terapêutica reabilitadora dos pacientes. O presente estudo tem por objetivo desenvolver uma metodologia de pós-processamento de imagens tomográficas para avaliação volumétrica de defeitos ósseos confeccionados em palato duro e rebordo alveolar de crânios macerados, mimetizando fissuras trans-forâmens unilaterais, e verificar a aplicabilidade clínica do Tomógrafo Computadorizado espiral Multislice e do tomógrafo computadorizado por feixe cônico na análise desses defeitos. Para tanto, nove crânios provenientes da Faculdade Cathedral, da cidade de Boa Vista- RR, foram escaneados em um Tomógrafo Computadorizado Multislice pertencente ao Hospital Geral de Roraima e em um tomógrafo computadorizado por feixe cônico de uma clínica privada, na cidade de Fortaleza-CE. As imagens foram, posteriormente, encaminhadas para análise ao Laboratório em Terceira Dimensão(LAB-3D) da Faculdade de Odontologia da USP, utilizando-se uma estação de trabalho independente e aplicando-se programas específicos de computação gráfica. Todas as imagens foram analisadas por dois examinadores, individualmente e em tempos distintos, por duas vezes, com o objetivo de processarmos análises intra e interexaminadores. Para a análise da metodologia de processamento de imagens, comparamos os resultados obtidos pelo Tomógrafo multislice utilizando crânios sem cera e com cera de modelagem número 07, na região do defeito ósseo, para auxiliar no seu delineamento, durante o pós-processamento das imagens tomográficas. Foram também avaliados os resultados volumétricos obtidos nos dois tipos de tomógrafos,com o objetivo de verificar a aplicabilidade dessas tecnologias na avaliação volumétrica dos defeitos ósseos fissurais e de comparar os resultados obtidos por cada uma delas. Todos os resultados foram comparados com os valores estabelecidos pelo padrão - ouro de nossa análise, que foram obtidos através do princípio de Arquimedes de deslocamento de água dos modelos de cera que foram utilizados. Os resultados estatísticos demonstraram que a metodologia de processamento das imagens tomográficas apresentou uma eficácia bastante elevada (p=0,995), sendo considerada eficiente na avaliação volumétrica de defeitos ósseos fissurais. Com relação aos tomógrafos utilizados, observamos que tanto o multislice como o por feixe cônico também apresentaram resultados satisfatórios, apresentando grande confiabilidade para o estudo do volume dos defeitos ósseos fissurais (p=0,997 e p=0,981, respectivamente), não havendo diferença nos resultados encontrados por eles. As análises intra e interobservadores nos dois tipos de tomógrafos não demonstraram diferença estatisticamente significativa. Os resultados evidenciaram que, independente do tipo de tomógrafo utilizado e do avaliador, as medidas obtidas são estatisticamente iguais às conseguidas pelo padrão-ouro de nossa análise. A aplicabilidade clínica de nossa pesquisa demonstrou ser direta e imediata, sendo importante no processo diagnóstico/terapêutico dos pacientes portadores de fissuras de rebordo alveolar e palato duro. / Oral clefts are one of the most frequent malformations of the human body, causing extensive facial bone deformities, compromising biological, psychic and social the individuals affected. Multislice CT and CBCT have been used to assess the volume of bone defect with the goal of diagnosis and rehabilitative therapy planning of the patients. The aim of this study were to develop a methodology for post-processing of tomographic images for volumetric assessment of bone defects made in the hard palate and alveolar ridge of dry skulls, mimicking unilateral trans-foramen clefts; and to determine the clinical applicability of multislice spiral computed tomography, and cone beam computed tomography in the analysis of these defects. Nine dry skulls from the Cathedral College in Boa Vista-RR were scanned on a multislice CT scanner at the Hospital Geral de Roraima and a cone beam computed tomography in a private clinic in Fortaleza-CE. The images were sent for analysis at Three Dimensional Laboratory (LAD-3D) of the Dentistry School, São Paulo University, using an independent workstation and implementing specific computer graphics programs. All images were analyzed by two examiners at different times and twice to proceed the intra and inter-examiners analysis. For analysis the methodology of image processing, we compared the results obtained by multislice CT using skulls with and without wax model in the region of bone defect. It was also analyzed the same images in both types of CT scanners in order to determine the applicability of these radiographic techniques in assessing volume of the clefts and to compare the results. All results were compared with the gold standard of our analysis, which was obtained by Archimedes principle of water displacement of wax models. The statistical results showed that the post processing methodology of tomographic images showed a high efficiency (p = 0.995) and was considered an efficient method for volumetric assessment of fissure bone defects. It was also observed that both multislice CT and cone beam CT showed excellent results with high reliability in the study of the volume of bone defects (p = 0.997 and p = 0.981, respectively), with no difference in performance between them. Analysis of intra-and inter-observer in the two types of CT scanners showed no statistically significant difference. The results demonstrate that independent of the type of CT scanner and the appraiser, the measurements are statistically equal to the gold standard obtained by our analysis. The clinical applicability of our research has shown to be immediate and direct, and it is important for the diagnostic and therapeutic process of patients with oral cleft.
7

Avaliação volumétrica de defeitos ósseos em fissuras de rebordo alveolar e palato duro por meio da 3D-TC multislice e feixe cônico / Volumetric assessment of hard palate and alveolar cleft using multislice and cone beam 3DCT

Marco Antonio Portela Albuquerque 11 November 2010 (has links)
As fissuras de rebordo alveolar e palato duro estão entre as malformações mais frequentes do corpo humano, podendo causar extensas deformidades ósseas faciais, com implicações biopsíquico-sociais marcantes. A avaliação da extensão desses defeitos ósseos, através de exames por imagem, tem sido feita com o objetivo de diagnosticar e planejar a terapêutica reabilitadora dos pacientes. O presente estudo tem por objetivo desenvolver uma metodologia de pós-processamento de imagens tomográficas para avaliação volumétrica de defeitos ósseos confeccionados em palato duro e rebordo alveolar de crânios macerados, mimetizando fissuras trans-forâmens unilaterais, e verificar a aplicabilidade clínica do Tomógrafo Computadorizado espiral Multislice e do tomógrafo computadorizado por feixe cônico na análise desses defeitos. Para tanto, nove crânios provenientes da Faculdade Cathedral, da cidade de Boa Vista- RR, foram escaneados em um Tomógrafo Computadorizado Multislice pertencente ao Hospital Geral de Roraima e em um tomógrafo computadorizado por feixe cônico de uma clínica privada, na cidade de Fortaleza-CE. As imagens foram, posteriormente, encaminhadas para análise ao Laboratório em Terceira Dimensão(LAB-3D) da Faculdade de Odontologia da USP, utilizando-se uma estação de trabalho independente e aplicando-se programas específicos de computação gráfica. Todas as imagens foram analisadas por dois examinadores, individualmente e em tempos distintos, por duas vezes, com o objetivo de processarmos análises intra e interexaminadores. Para a análise da metodologia de processamento de imagens, comparamos os resultados obtidos pelo Tomógrafo multislice utilizando crânios sem cera e com cera de modelagem número 07, na região do defeito ósseo, para auxiliar no seu delineamento, durante o pós-processamento das imagens tomográficas. Foram também avaliados os resultados volumétricos obtidos nos dois tipos de tomógrafos,com o objetivo de verificar a aplicabilidade dessas tecnologias na avaliação volumétrica dos defeitos ósseos fissurais e de comparar os resultados obtidos por cada uma delas. Todos os resultados foram comparados com os valores estabelecidos pelo padrão - ouro de nossa análise, que foram obtidos através do princípio de Arquimedes de deslocamento de água dos modelos de cera que foram utilizados. Os resultados estatísticos demonstraram que a metodologia de processamento das imagens tomográficas apresentou uma eficácia bastante elevada (p=0,995), sendo considerada eficiente na avaliação volumétrica de defeitos ósseos fissurais. Com relação aos tomógrafos utilizados, observamos que tanto o multislice como o por feixe cônico também apresentaram resultados satisfatórios, apresentando grande confiabilidade para o estudo do volume dos defeitos ósseos fissurais (p=0,997 e p=0,981, respectivamente), não havendo diferença nos resultados encontrados por eles. As análises intra e interobservadores nos dois tipos de tomógrafos não demonstraram diferença estatisticamente significativa. Os resultados evidenciaram que, independente do tipo de tomógrafo utilizado e do avaliador, as medidas obtidas são estatisticamente iguais às conseguidas pelo padrão-ouro de nossa análise. A aplicabilidade clínica de nossa pesquisa demonstrou ser direta e imediata, sendo importante no processo diagnóstico/terapêutico dos pacientes portadores de fissuras de rebordo alveolar e palato duro. / Oral clefts are one of the most frequent malformations of the human body, causing extensive facial bone deformities, compromising biological, psychic and social the individuals affected. Multislice CT and CBCT have been used to assess the volume of bone defect with the goal of diagnosis and rehabilitative therapy planning of the patients. The aim of this study were to develop a methodology for post-processing of tomographic images for volumetric assessment of bone defects made in the hard palate and alveolar ridge of dry skulls, mimicking unilateral trans-foramen clefts; and to determine the clinical applicability of multislice spiral computed tomography, and cone beam computed tomography in the analysis of these defects. Nine dry skulls from the Cathedral College in Boa Vista-RR were scanned on a multislice CT scanner at the Hospital Geral de Roraima and a cone beam computed tomography in a private clinic in Fortaleza-CE. The images were sent for analysis at Three Dimensional Laboratory (LAD-3D) of the Dentistry School, São Paulo University, using an independent workstation and implementing specific computer graphics programs. All images were analyzed by two examiners at different times and twice to proceed the intra and inter-examiners analysis. For analysis the methodology of image processing, we compared the results obtained by multislice CT using skulls with and without wax model in the region of bone defect. It was also analyzed the same images in both types of CT scanners in order to determine the applicability of these radiographic techniques in assessing volume of the clefts and to compare the results. All results were compared with the gold standard of our analysis, which was obtained by Archimedes principle of water displacement of wax models. The statistical results showed that the post processing methodology of tomographic images showed a high efficiency (p = 0.995) and was considered an efficient method for volumetric assessment of fissure bone defects. It was also observed that both multislice CT and cone beam CT showed excellent results with high reliability in the study of the volume of bone defects (p = 0.997 and p = 0.981, respectively), with no difference in performance between them. Analysis of intra-and inter-observer in the two types of CT scanners showed no statistically significant difference. The results demonstrate that independent of the type of CT scanner and the appraiser, the measurements are statistically equal to the gold standard obtained by our analysis. The clinical applicability of our research has shown to be immediate and direct, and it is important for the diagnostic and therapeutic process of patients with oral cleft.
8

Estimativa do tempo de reparo ósseo em dentes com lesão periapical tratados endodonticamente utilizando modelagem matemática / Estimation of bone repair time in teeth with periapical lesion treated endodontically using mathematical modeling

Ungaro, Daniela Maria de Toledo [UNESP] 15 August 2018 (has links)
Submitted by Daniela Maria de Toledo Ungaro (danielamt_ungaro@yahoo.com.br) on 2018-09-27T12:43:41Z No. of bitstreams: 1 Daniela Ungaro Finalizado para impressão.pdf: 3219565 bytes, checksum: 8ee8e24e21d6105d1be4113a492c91f5 (MD5) / Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2018-09-27T14:48:02Z (GMT) No. of bitstreams: 1 ungaro_dmt_me_sjc.pdf: 3219565 bytes, checksum: 8ee8e24e21d6105d1be4113a492c91f5 (MD5) / Made available in DSpace on 2018-09-27T14:48:02Z (GMT). No. of bitstreams: 1 ungaro_dmt_me_sjc.pdf: 3219565 bytes, checksum: 8ee8e24e21d6105d1be4113a492c91f5 (MD5) Previous issue date: 2018-08-15 / Os objetivos deste estudo foram avaliar, com a ajuda de um modelo matemático, o tempo estimado para ocorrer reparo ósseo em dentes com lesão periapical tratados endodonticamente e comparar o volume da lesão periapical (em mm3) após a utilização de dois tipos de medicação intracanal. Para isso, foram selecionados 34 dentes unirradiculares com lesão periapical de pacientes da Disciplina de Endodontia do ICT/SJC-UNESP que necessitavam de tratamento endodôntico. Após a seleção dos dentes, foram obtidas radiografias periapicais (RP) e tomografias computadorizadas de feixe cônico (TCFC) antes de iniciar o tratamento endodôntico (T0). Os dentes foram divididos em dois grupos de acordo com a medicação intracanal utilizada (n=17): G1 – Hidróxido de cálcio associado à Clorexidina Gel 2% e G2 – Ultracal XS®. Foram obtidas novas radiografias periapicais e tomografias (TCFC) após o término do tratamento endodôntico (T1), sendo outras após 3 meses (T2) e também após 6 meses (T3). Os arquivos das tomografias foram exportados no formato DICOM (Digital Imaging and Communications in Medicine) para avaliar a volumetria das lesões pré e pós tratamento (em voxel/mm3) pelo processo de segmentação semiautomático em todos os períodos de tempo pré-estabelecidos (T0, T1, T2 e T3), por meio do software de livre acesso ITK-SNAP1.4.1 (University of North Carolina, Chapel Hill, NC, USA). Após a análise da volumetria das lesões periapicais em todos os períodos de tempo, os dados obtidos foram utilizados para construir um modelo matemático que foi empregado para estimar o tempo de reparo ósseo das lesões. Os dados obtidos foram analisados estatisticamente pelo Teste t - Student de amostras independentes (p<0,05). Houve diminuição do volume da lesão periapical nos casos tratados endodonticamente e a medicação intracanal utilizada, seja Hidróxido de cálcio + Clorexidina gel 2% ou Ultracal®, não apresentou diferença significativa no tempo de reparo ósseo nem no volume da lesão periapical nos períodos pré-determinados. Não houve diferença na estimativa de tempo de reparo ósseo entre os grupos avaliados, sendo, em média, 249 dias para o G1 e 245 dias para o G2. A utilização de um modelo matemático para estimativa de reparo ósseo pode ser uma alternativa viável na previsão do tempo de reparo dos casos tratados endodonticamente. / The objectives of this study were to evaluate the estimated time for bone repair in teeth with periapical lesions treated endodontically and to compare the volume of the periapical lesion (in mm3) with the help of a mathematical model after the use of two types of intracanal medication. For this, 34 single rooted teeth with periapical lesion were selected from patients of the Endodontic Discipline of the ICT/SJC-UNESP who needed endodontic treatment. After the teeth were selected, periapical radiography (RP) and cone-beam computed tomography (CBCT) were obtained before starting the endodontic treatment. The teeth were divided into two groups according to the intracanal medications used (n=17): G1 - Calcium hydroxide associated with 2% chlorhexidine gel and G2 – Ultracal XS®. New periapical radiographs and tomographys (CBCT) were obtained after endodontic treatment (T1), others after 3 months (T2) and after 6 months (T3). The files of CBCT were exported in DICOM (Digital Imaging and Communications in Medicine) format to evaluate the volumetry of pre and post-treatment lesions (voxel/mm3) by the semi-automatic segmentation process at all the pre-established time periods (T0, T1, T2, T3) through the free access software ITK SNAP-1.4.1 (University of North Carolina, Chapel Hill, NC, USA). After the analysis of the periapical lesion volume in all time periods, the data were used to construct a mathematical model that was used to estimate the bone repair time of the lesion. The data obtained were statistically analyzed by Student's t - test of independent samples (p <0.05). ). There was a decrease in the volume of the periapical lesion in endodontically treated cases and the intracanal medication used, whether calcium hydroxide + chlorhexidine gel 2% or Ultracal®, did not present a significant difference in bone repair time nor in the periapical lesion volume in the predetermined periods. There was no difference in the estimated bone repair time between the groups evaluated, being, on average, 249 days for G1 and 245 days for G2. The use of a mathematical model for estimation of bone repair may be a viable alternative in predicting the repair time of endodontically treated cases.

Page generated in 0.0817 seconds