• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • Tagged with
  • 11
  • 11
  • 8
  • 8
  • 7
  • 7
  • 6
  • 6
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Relaxações anelásticas devido a reorientação induzida por tensão de defeitos pontuais em nióbio e tântalo / Anelastic relaxation due to stress induced orderingof point defects in niobium and tantalum

Scalvi, Rosa Maria Fernandes 05 October 1993 (has links)
Esta dissertação mostra a análise da interação de intersticiais pesados como oxigênio e nitrogênio em amostras policristalinas de nióbio e monocristalinas de nióbio e tânalo. Os dados experimentais foram obtidos através de medidas de atrito interno e freqüência de oscilação do pêndulo em função da temperatura, utilizando-se um pêndulo de torção invertido tipo Kê. Os resultados mostram estruturas de relaxação atribuídas à reorientação induzida por tensão de átomos intersticiais em torno de átomos da matriz metálica. Estas estruturas forma analisadas através de dois métodos: subtrações sucessivas e tempo de relaxação. A partir das medidas de atrito interno foram identificados os processos de relaxações Nb-O, Nb-N e Ta-O. Esses mesmos processos de relaxação foram confirmados por meio das medidas de freqüência de oscilação do pendulo usando um método proposto nesta dissertação, o qual relaciona o quadrado dessa freqüência medida e o inverso da temperatura. / This dissertation shows the analysis of heavy interstitials interaction, such as oxygen and nitrogen, in a policrystalline niobium sample and single crystal samples of niobium and tantalum. The experimental data were obtained by internal friction and oscillation frequency measurements as a function of temperature, using a Kê-type inverted torsion pendulum. The results show relaxation structures attributed to stress induced ordering of interstitial atoms around the mettalic matrix atoms. These structures were analysed by two methods: sucessive subtraction and relaxation time. From internal friction measurements, Nb-O, Nb-N and Ta-O relaxation processes were identified. These same relaxation processes were confirmed by oscillation frequency measurements, using a method proposed here, which relates squared frequency with inverse of temperature.
2

Efeito do nitrogênio nas propriedades anelásticas de Nb e ligas Nb-1,0%pZr

Souza, Armando Cirilo de [UNESP] 22 June 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:04Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-06-22Bitstream added on 2014-06-13T18:41:33Z : No. of bitstreams: 1 souza_ac_dr_bauru.pdf: 4889412 bytes, checksum: b1b5556d4915022278e65a9a1b120315 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O desenvolvimento científico e tecnológico na área de novos materiais contribui para diversas aplicações do nióbio e suas ligas nas indústrias aeroespacial, aeronáutica, automobilística, naval, usinas nucleares, etc. O Brasil lidera o cenário mundial na oferta de nióbio, atingindo uma participação de 92,4% da produção mundial, justificando, assim, o interesse no estudo desse metal. Este trabalho tem dois objetivos: o primeiro é garantir a introdução do nitrogênio em solução sólida intersticial na matriz metálica Nb sob pressão parcial na ordem de 'X POT.-4' Torr e temperatura na ordem de 173 K, com diferentes tempos de dopagens; e, o segundo é caracterizar a liga Nb-1,0%pZr em termos de suas propriedades anelásticas, com diferentes concentrações de nitrogênio em solução sólida, tendo como referência padrão o metal nióbio. Pelo emprego do método de Espectroscopia Mecânica com base na técnia de atrito interno, que fornece informações sobre as interações Gás-Metal e outras técnicas auxiliares, como Difração de Raios X e Microscopia Eletrônica, foi possível mostrar a introdução de nitrogênio em solução em nióbio sob baixas condições de temperatura e pressão. Além disso, foi efetuada a caracterização anelástica da liga Nb-1,0%pZr em função do aumento da concentração de nitrogênio em solução sólida. / The scientific and technological development in the area of new materials has contributed to severa applications of niobium and its alloys to the aerospatial, aeronautical, automotive and naval industries, nuclear power stations, among others. Brazil is a worldwide leader in the supply of supply of niobium, reaching 92.4% share in the world production, thus justifying the interest in the study of that metal. In the present paper, there are two objectives: the first is to guarantee the introduction of nitrogen in an interstitial solid solution of niobium under partial pressure of 10-4 Torr and at a temperature of aound 1373 K, with different doping times. The second one is to characterize a Nb-1,0%Zr alloy according to its anelastic relaxation properties, with different nitrogen concentration in a solid solution, having niobium as a reference. By using Mechanical Spectroscopy, and bases on the internal friction technique - which provides information on Metal-Gas interactions and others auxiliary techniques, such as X-Ray Diffraction and Scanning Electron Microscopy - it was possible to show the introduction of nitrogen in a solid solution in niobium at a low temperature and pressure conditions. In addition, the anelastic characterization of the Nb-1,0%Zr alloy was performed in therms of the nitrogen concentration in a solid solution, showing complex anelastic relaxation structures, which were decomposed into their component relaxation processes due to stress-induced ordering of oxygen and nitrogen atoms around niobium and zirconium atoms.
3

Relaxações anelásticas devido a reorientação induzida por tensão de defeitos pontuais em nióbio e tântalo / Anelastic relaxation due to stress induced orderingof point defects in niobium and tantalum

Rosa Maria Fernandes Scalvi 05 October 1993 (has links)
Esta dissertação mostra a análise da interação de intersticiais pesados como oxigênio e nitrogênio em amostras policristalinas de nióbio e monocristalinas de nióbio e tânalo. Os dados experimentais foram obtidos através de medidas de atrito interno e freqüência de oscilação do pêndulo em função da temperatura, utilizando-se um pêndulo de torção invertido tipo Kê. Os resultados mostram estruturas de relaxação atribuídas à reorientação induzida por tensão de átomos intersticiais em torno de átomos da matriz metálica. Estas estruturas forma analisadas através de dois métodos: subtrações sucessivas e tempo de relaxação. A partir das medidas de atrito interno foram identificados os processos de relaxações Nb-O, Nb-N e Ta-O. Esses mesmos processos de relaxação foram confirmados por meio das medidas de freqüência de oscilação do pendulo usando um método proposto nesta dissertação, o qual relaciona o quadrado dessa freqüência medida e o inverso da temperatura. / This dissertation shows the analysis of heavy interstitials interaction, such as oxygen and nitrogen, in a policrystalline niobium sample and single crystal samples of niobium and tantalum. The experimental data were obtained by internal friction and oscillation frequency measurements as a function of temperature, using a Kê-type inverted torsion pendulum. The results show relaxation structures attributed to stress induced ordering of interstitial atoms around the mettalic matrix atoms. These structures were analysed by two methods: sucessive subtraction and relaxation time. From internal friction measurements, Nb-O, Nb-N and Ta-O relaxation processes were identified. These same relaxation processes were confirmed by oscillation frequency measurements, using a method proposed here, which relates squared frequency with inverse of temperature.
4

Difusão e relaxação anelástica devido ao hidrogênio em solução sólida em ligas de Nb-Ti e Nb-Zr. / Diffusion and anelastic relaxation due to hydrogen in solid solution in Nb-Ti and Nb-Zr alloys.

Grandini, Carlos Roberto 14 May 1993 (has links)
Foi estudado o efeito do hidrogênio dissolvido intersticialmente em ligas de nióbio-titânio e nióbio-zircônio. Nas ligas de nióbio-titânio, foram efetuadas medidas de decremento logarítmico por intermédio de medidas de atrito interno em um pêndulo de torção oscilando com freqüência em torno de 4.0 Hz, para amostras puras e dopadas com hidrogênio. Os resultados mostraram a interação do hidrogênio com a matriz metálica através do Efeito Gorsky. Nas ligas de nióbio-zircônio, foram efetuadas medidas de atenuação ultra-sônica para freqüências de 10 e 30 MHz, em amostras puras, contendo hidrogênio e contendo oxigênio e hidrogênio. Os resultados mostraram a interação do hidrogênio com a matriz metálica através de um processo de reorientação induzida por tensão de átomos de hidrogênio localizados em sítios intersticiais tetraedrais em torno de átomos de oxigênio congelados em sítios intersticiais octaedrais, próximos de átomos de nióbio da matriz metálica. / We study the effect of hydrogen dissolved interstitially in niobium-titanium and niobium-zirconium alloys. In the niobimn-titanium alloys, the logarithmic decrement was studied by internal friction measurements in a torsion pendulum with frequency about 4.0 Hz, on pure and hydrogen doped samples. Our results showed the interaction of hydrogen with the metallic matrix by the Gorsky effect. In the niobium-zirconium alloys, the ultrasonic attenuation was measured by the echo-pulse method with frequencies of 10 and 30 MHz, for pure, doped with hydrogen and doped with oxygen and hydrogen. The results have shown the interaction of hydrogen with the metallic matrix by a stress induced ordering of hydrogen atoms localized at tetrahedral sites around frozen oxygen atoms localized in the octahedral sites near the niobium atoms in the metallic matrix.
5

Estudo de multi-espectro de relaxação anelástica devido a defeitos intersticiais em ligas de Nb-Zr e Nb-Ti. / Study of the anelastic relaxation multi-spectra due to interstitial deffects in Nb-Zr and Nb-Ti alloys.

Grandini, Carlos Roberto 06 May 1988 (has links)
As medidas de atrito interno tem sido muito usadas para o estudo de relaxações anelásticas devido à intersticiais em metais ou ligas metálicas. Estudou-se o comportamento de ligas de Nb-Zr dopadas com Oxigênio e ligas de Nb-Ti dopadas com Oxigênio e Nitrogênio, através de medidas simultâneas de atrito interno (energia dissipada por oscilação do Pêndulo de Torção) e da dispersão dos valores reativos da constante elástica apropriada. No sistema Nb-Zr-O, o multi espectro de relaxação em função da temperatura foi analisado e foram encontrados processos de relaxação devido à reorientação induzida por tensão de um, dois e três átomos de Oxigênio em torno de um átomo de Nióbio e um átomo de Oxigênio em torno de um átomo de Zircônio. No sistema NB-Ti-O-N, foram encontrados processos de relaxação devido à reorientação induzida por tensão de um e dois átomos de Oxigênio em torno de um átomo de Nióbio e um átomo de Titânio, respectivamente; um átomo de Nitrogênio em torno de um átomo de Nióbio e um átomo de Titânio, respectivamente. Com a ajuda das relações desenvolvidas por Kramers-Krönig, foi possível prever e checar com precisão cada intensidade de relaxação através das medidas da variação relativa da constante elástica apropriada (dispersão). / Internal friction measurements have been very often used for anelastic relaxation investigation in order to detect the existence of the interstitials in metal or metal alloys. The behavior of the Nb-Zr alloys doped with oxygen and the Nb-Ti alloys doped with oxygen and nitrogen have been studied using internal friction and relative elastic constants measurements obtained simultaneously. For Nb-Zr-O system, the multi-relaxation spectrum has been analyzed and relaxation processes due to the stress-induced ordenaring of one, two or three oxygen atoms around one niobium atom and also one oxygen atom around one zirconium atom went found. For Nb-Ti-O-N system, the multi-relaxation spectrum has been analyzed and relaxation processes due to the stress-induced ordenaring of one and two oxygen atoms around one niobium and titanium atoms respectively and one nitrogem atom around one niobium and titanium atoms respectively. With aid of Kramers-Krönig relations, it was possible to preview and check with good accuracy each of relaxation measurements.
6

Efeito do oxigênio nas propriedades anelásticas da liga Ti-10Mo para aplicação biomédica

Nogueira, Renata Abdallah [UNESP] 25 January 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:29Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-01-25Bitstream added on 2014-06-13T18:50:40Z : No. of bitstreams: 1 nogueira_ra_me_bauru_prot.pdf: 2628699 bytes, checksum: 548bffb406de71f06f0ab9ae6a52d7c8 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A utilização de biomateriais do reparo do tecido ósseo tem revolucionado a Ortopedia e a Odontologia atuais. Um metal estudado para estas aplicações é o titânio e suas ligas, pois possuem um excelente grau de biocompatibilidade com o organismo humano, uma excelente resistência à corrosão em meio biológico e uma ótima relação resistência mecânica/densidade. Estas propriedades são fortemente influenciadas pela presença de lementos intersticiais e as medidas de atrito interno têm sido muito utilizadas para verificar o comportamento destes elementos em materiais. O objetivo neste trabalho foi estudar o efeito de elementos intersticiais nas propriedades da liga Ti-10Mo (% em peso), por meio de medidas de difração de raios X, microscopia eletrônica e varredura, testes de citotoxidade, corrosão e espectroscopia mecânica. As amostras foram submetidas a tratamentos térmicos de recozimento e dopagem com oxigênio. Os testes de biocompatibilidade mostraram que não houve nenhuma resposta indireta. Os extratos dos materiais não interferiram no desenvolvimento, crescimento e proliferação das células. Foi detectada uma melhora na taxa de corrosão, juntamente com um aumento do potencial de corrosão, com a dopagem do material, características estas interessantes para um biomaterial. Os resultados de espectroscopia mecânica mostraram a presença de uma estrutura de relaxação após a dopagem com oxigênio em torno de átomos dos elementos que compõem a liga. Observou-se que a adição de oxigênio intersticial causou um aumento no módulo de elasticidade, o que é ruim quando se trata de um biomaterial para implantes ortopédicos. / The use of the biomaterials in the repair of the bone tissue has been revolutionizing the Orthopedics and the Odontology. A metal very studied for these applications is the titanium and its alloys, because they possess an excellent corrosion resistance in a biological media and a good relationship mechanical strength/density. These properties are strongly influenced by the presence of interstitial elements and the internal friction measurements have been a lot used to verify the behavior of these interstitial elements in materials. The objective of this work was to study the effect of interstitial elements in the properties of the Ti-10Mo (%in weight) alloy, through X-ray diffraction, scanning electron microscopy, cytotoxicity tests, corrosion and mechanical spectroscopy. The samples were submitted to heat treatments of annealing and oxygen doping. The biocompatibility tests showed that there was not any indirect cytotoxic answer. The extracts of the materials didn't interfere in the development, growth and proliferation of the cells. An increase in the corrosion rate was detected, with an increase of the corrosion potential, with the oxygen doping, interesting for applications as biomaterial. The mechanical spectroscopy results showed the presence of a relaxation structure after the oxygen doping that was attributed mainly to the stress-induced ordering of the oxygen atoms around the atoms that compose the alloy. It was observed an increase in the elasticity with the oxygen doping, what is bad when it is a biomaterial.
7

Estudo de multi-espectro de relaxação anelástica devido a defeitos intersticiais em ligas de Nb-Zr e Nb-Ti. / Study of the anelastic relaxation multi-spectra due to interstitial deffects in Nb-Zr and Nb-Ti alloys.

Carlos Roberto Grandini 06 May 1988 (has links)
As medidas de atrito interno tem sido muito usadas para o estudo de relaxações anelásticas devido à intersticiais em metais ou ligas metálicas. Estudou-se o comportamento de ligas de Nb-Zr dopadas com Oxigênio e ligas de Nb-Ti dopadas com Oxigênio e Nitrogênio, através de medidas simultâneas de atrito interno (energia dissipada por oscilação do Pêndulo de Torção) e da dispersão dos valores reativos da constante elástica apropriada. No sistema Nb-Zr-O, o multi espectro de relaxação em função da temperatura foi analisado e foram encontrados processos de relaxação devido à reorientação induzida por tensão de um, dois e três átomos de Oxigênio em torno de um átomo de Nióbio e um átomo de Oxigênio em torno de um átomo de Zircônio. No sistema NB-Ti-O-N, foram encontrados processos de relaxação devido à reorientação induzida por tensão de um e dois átomos de Oxigênio em torno de um átomo de Nióbio e um átomo de Titânio, respectivamente; um átomo de Nitrogênio em torno de um átomo de Nióbio e um átomo de Titânio, respectivamente. Com a ajuda das relações desenvolvidas por Kramers-Krönig, foi possível prever e checar com precisão cada intensidade de relaxação através das medidas da variação relativa da constante elástica apropriada (dispersão). / Internal friction measurements have been very often used for anelastic relaxation investigation in order to detect the existence of the interstitials in metal or metal alloys. The behavior of the Nb-Zr alloys doped with oxygen and the Nb-Ti alloys doped with oxygen and nitrogen have been studied using internal friction and relative elastic constants measurements obtained simultaneously. For Nb-Zr-O system, the multi-relaxation spectrum has been analyzed and relaxation processes due to the stress-induced ordenaring of one, two or three oxygen atoms around one niobium atom and also one oxygen atom around one zirconium atom went found. For Nb-Ti-O-N system, the multi-relaxation spectrum has been analyzed and relaxation processes due to the stress-induced ordenaring of one and two oxygen atoms around one niobium and titanium atoms respectively and one nitrogem atom around one niobium and titanium atoms respectively. With aid of Kramers-Krönig relations, it was possible to preview and check with good accuracy each of relaxation measurements.
8

Difusão e relaxação anelástica devido ao hidrogênio em solução sólida em ligas de Nb-Ti e Nb-Zr. / Diffusion and anelastic relaxation due to hydrogen in solid solution in Nb-Ti and Nb-Zr alloys.

Carlos Roberto Grandini 14 May 1993 (has links)
Foi estudado o efeito do hidrogênio dissolvido intersticialmente em ligas de nióbio-titânio e nióbio-zircônio. Nas ligas de nióbio-titânio, foram efetuadas medidas de decremento logarítmico por intermédio de medidas de atrito interno em um pêndulo de torção oscilando com freqüência em torno de 4.0 Hz, para amostras puras e dopadas com hidrogênio. Os resultados mostraram a interação do hidrogênio com a matriz metálica através do Efeito Gorsky. Nas ligas de nióbio-zircônio, foram efetuadas medidas de atenuação ultra-sônica para freqüências de 10 e 30 MHz, em amostras puras, contendo hidrogênio e contendo oxigênio e hidrogênio. Os resultados mostraram a interação do hidrogênio com a matriz metálica através de um processo de reorientação induzida por tensão de átomos de hidrogênio localizados em sítios intersticiais tetraedrais em torno de átomos de oxigênio congelados em sítios intersticiais octaedrais, próximos de átomos de nióbio da matriz metálica. / We study the effect of hydrogen dissolved interstitially in niobium-titanium and niobium-zirconium alloys. In the niobimn-titanium alloys, the logarithmic decrement was studied by internal friction measurements in a torsion pendulum with frequency about 4.0 Hz, on pure and hydrogen doped samples. Our results showed the interaction of hydrogen with the metallic matrix by the Gorsky effect. In the niobium-zirconium alloys, the ultrasonic attenuation was measured by the echo-pulse method with frequencies of 10 and 30 MHz, for pure, doped with hydrogen and doped with oxygen and hydrogen. The results have shown the interaction of hydrogen with the metallic matrix by a stress induced ordering of hydrogen atoms localized at tetrahedral sites around frozen oxygen atoms localized in the octahedral sites near the niobium atoms in the metallic matrix.
9

Anelasticidade em titânio, tântalo e na liga Ti-40Ta

Patricio, Marco Antonio Tito 24 July 2014 (has links)
Made available in DSpace on 2016-06-02T20:16:53Z (GMT). No. of bitstreams: 1 5978.pdf: 11727715 bytes, checksum: 7ecd56710aed6f64b6e687a355a259bf (MD5) Previous issue date: 2014-07-24 / Financiadora de Estudos e Projetos / The growing demand for increasingly resistant and biocompatible with the human body implantable materials, has led to an increase in demand for new metallic biomaterials. Some materials, such as titanium and its alloys, especially the Ti-6Al-4V, are widely used in the manufacture of orthopedic implants due to their excellent biocompatibility, high corrosion resistance and low density. However, the characteristics of these materials are not considered optimal, mainly because they have a high value of the elastic modulus when compared to the human bone. Include, that in the last decade studies have revealed diseases associated with elements such as Al and V, present in the alloy Ti-6Al-4V. Thus, it have looked for alternatives to the alloys used as biomaterials, still having one common element titanium, but having no toxic elements such as 𝛽 type titanium alloys, formed by non-toxic elements such as Nb, Ta, Zr, Mo and Sn has shown that lower values of modulus, greater fatigue resistance and corrosion resistance, exhibiting excellent biocompatibility. Accordingly, the alloys formed by Ti-Ta become promising candidates as biomaterials, since it has been observed that the content of Ta affects the value of the elastic modulus. For some compositions of this alloy, lower modulus values of this alloys that are currently used in biomedical applications were observed. However, the alloys formed by Ti-Ta still have properties that have been little studied. Thereby, the objectives of this master s project consist in getting the alloy Ti-40Ta and its characterization by means of the technique of mechanical spectroscopy, as of its elements that compose the alloy. The technique of mechanical spectroscopy to be non-destructive, it is widely used for providing the anelastic spectrum (oscillation frequency and internal friction as a function of temperature) is considered sensitive to phase transitions and dynamic processes, which are essential for understanding the structural changes occurring in these materials. This study was determined the dynamic elastic modulus for the pure Ti and Ta elements, and the Ti-40Ta through flexural vibrations. The elastic modulus found for the alloy at room temperature was (71 ± 5) GPa, which is in accordance with results available in the literature. The value of modulus of the alloy is lower when compared to the commercial biomedical alloys and is closer to that of human bone, which makes the alloy Ti-40Ta a potential candidate to be used in biomedical applications. / A crescente demanda por materiais implantáveis cada vez mais resistentes e biocompatíveis com o organismo humano, tem levado a um aumento na procura por novos biomateriais metálicos. Alguns materiais, como o titânio e suas ligas, com destaque para a liga Ti-6Al-4V, são largamente utilizados na fabricação de implantes ortopédicos devido as suas excelentes características como biocompatibilidade, alta resistência à corrosão e baixa densidade. Entretanto, as características desses materiais ainda não são consideradas ideais, principalmente porque apresentam um alto valor do módulo de elasticidade quando comparado com o osso humano. Cabe mencionar, que na última década estudos revelaram doenças associadas a elementos como o Al e V, presentes na liga Ti-6Al-4V. Desta forma, busca-se alternativas às ligas empregadas como biomateriais, ainda contendo como elemento principal o titânio, mas que não possuam elementos tóxicos. Estudos recentes mostram que as ligas de titânio tipo 𝛽, formadas por elementos não tóxicos como Nb, Ta, Zr, Mo e Sn, tem apresentado valores mais baixos módulo de elasticidade, maior resistência à fadiga e maior resistência à corrosão, além de exibir uma excelente biocompatibilidade. Neste sentido, as ligas formadas por Ti-Ta tornaram-se candidatas promissoras como biomateriais, uma vez que, foi observado que o teor de Ta afeta o valor do módulo de elasticidade. Para algumas composições, desta liga, foram observados valores de módulo inferiores as ligas de Ti que atualmente são empregadas em aplicações biomédicas. No entanto, as ligas formadas por Ti-Ta ainda possuem propriedades pouco estudadas. Deste modo, os objetivos deste projeto de mestrado consistem na obtenção da liga Ti-40Ta e na sua caracterização por meio da técnica de espectroscopia mecânica, bem como a de cada elemento que compõem a liga. A técnica de espectroscopia mecânica, por ser não destrutiva, é amplamente usada por fornecer o espectro anelástico (frequência de oscilação e atrito interno em função da temperatura), sendo considerada sensível a transições de fase e a processos dinâmicos, que são essenciais para compreender as alterações estruturais que ocorrem nestes materiais. Neste estudo, determinou-se o módulo de elasticidade dinâmico para os elementos puros, Ti e Ta, e para a liga Ti-40Ta por meio das vibrações flexurais. O módulo de elasticidade encontrado para a liga, em temperatura ambiente, foi de (71 ± 5) GPa, estando em concordância com os resultados disponíveis na literatura. O valor de módulo da liga é menor quando comparado ao das ligas biomédicas comerciais e está mais próximo a do osso humano, o que a torna a liga Ti-40Ta uma potencial candidata a ser empregada em aplicações biomédicas.
10

Processamento e propriedades do sistema ferroelétrico livre de chumbo (Bi, Na)TiO3 (Bi, K)TiO3 BaTiO3

Barbosa Quiroga, David Antonio 09 March 2015 (has links)
Made available in DSpace on 2016-06-02T20:16:54Z (GMT). No. of bitstreams: 1 6698.pdf: 13275782 bytes, checksum: 2c4bbd5a5c838552f7cbf82ce709e116 (MD5) Previous issue date: 2015-03-09 / Financiadora de Estudos e Projetos / In this work, the lead-free ceramic powders of xBi0,5Na0,5TiO3 - (0,7186 - 0,7143x) Bi0,5K0,5TiO3 - (2814 - 2857x) BaTiO with x = 0,8200; 0,8625; 0,8792, 0,9126 and 0,9300 (BNBK1000x) were prepared by the solid state reaction method, followed by conventional densification. The ceramic bodies showed high density, which was higher than 95% in obtained samples. For the all ceramics were performed structural, micro structural, electric and anelastic characterizations. The X-ray diffraction (XRD) analysis indicated the formation of the complex perovskite type crystaline structure for all compositions analyzed without the presence of spurious phases. By the structural refinement by the Rietveld method of XRD data and by Raman spectroscopy were observed that for BNBK912 and BNBK930 compositions, at room temperature, the predominant symmetry is rhombohedral (R3c), while the BNBK820 composition exhibits a tetragonal crystalline symmetry (P4mm). For the BNBK879 and BNBK826 compositions presented a mixture of phases, possibly with rhombohedral and tetragonal symmetry, reaveling the morphotropic phase boundary (MPB) of this system. The microstructure of BNBK1000x ceramics was investigated by scanning electron microscopy (SEM), where the morphology grains with irregular sizes and shapes, where the increased levels of K+ and Ba2+ ions suppressed the growth of the grains. The characterizations by Raman spectroscopy at room temperature showed broad Raman modes, due to the chemical and/or structural disorder related to the substitution of elements Bi and Na for Ba and K. The ferroelectric characterizations at room temperature of the BNBK1000x ceramics showed that all compositions studied are ferroelectric. Through the comparison among the measurements of electrical impedance and mechanical spectroscopy, was possible to identify the different structural and electric phase transitions that were employed in the construction of a pseudodiagram of phases for the BNBK1000x compositions. / Neste trabalho, os pós-cerâmicos livres de chumbo xBi0,5Na0,5TiO3 - (0,7186 - 0,7143x) Bi0,5K0,5TiO3 - (2814 - 2857x) BaTiO com x = 0,8200; 0,8625; 0,8792, 0,9126 e 0,9300 (BNBK1000x) foram obtidos através do método de reação de estado sólido, seguido por densificação convencional. Os corpos cerâmicos obtidos apresentaram elevada densificação, sendo maior que 95% nas amostras produzidas. Para todas as cerâmicas foram realizadas caracterizações estruturais, microestruturais, elétricas e anelásticas. As análises por difração de raios-X (DRX) indicaram a formação da estrutura cristalina tipo perovkista complexa para todas as composições analisadas, sem a presença de fases espúrias. O refinamento estrutural, pelo método de Rietveld, dos resultados de DRX e os resultados de espectroscopia Raman apontam que para as composições BNBK930 e BNBK912 a simetria predominante em temperatura ambiente é romboédrica (R3c), enquanto que a composição BNBK820 apresenta a simetria cristalina tetragonal (P4mm). Já as composições BNBK879 e BNBK862 apresentaram uma mistura de fases, possivelmente com simetrias romboédrica e tetragonal, evidenciando o contorno de fase morfotrópico (CFM) deste sistema. A microestrutura das cerâmicas de BNBK1000x foi investigada por microscopia eletrônica de varredura (MEV), onde a morfologia apresentada pelas diferentes composições estudadas possuíam grãos com tamanhos e formatos irregulares, sendo que o aumento dos teores dos íons de K+ e Ba2+ inibiram o crescimento dos grãos. A caracterização por espectroscopia Raman, em temperatura ambiente, apresentou modos Raman amplos, mostrando um elevado grau de desordem química e/ou estrutural devido à substituição dos elementos Bi e Na por Ba e K. As caracterizações ferroelétricas, também em temperatura ambiente das cerâmicas de BNBK1000x mostraram que todas as composições estudadas possuem propriedades ferroelétricas. Através da comparação entre as medidas de impedância elétrica e anelástica, levando em consideração as caracterizações estruturais e ferroelétricas com temperatura, foi possível identificar diferentes transições de fase estruturais e elétricas, que foram empregadas na construção de um pseudo-diagrama de fases para as composições de BNBKx.

Page generated in 0.0652 seconds