• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 527
  • 25
  • 25
  • 25
  • 23
  • 14
  • 13
  • 13
  • 12
  • 8
  • 6
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 537
  • 200
  • 161
  • 101
  • 91
  • 85
  • 81
  • 74
  • 71
  • 71
  • 70
  • 70
  • 69
  • 68
  • 67
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Análise das angulações mésio-distais de bráquetes pré-ajustados

Verri, Ana Caroline Gonçales [UNESP] 09 February 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-02-09Bitstream added on 2014-06-13T18:32:09Z : No. of bitstreams: 1 verri_acg_me_araca.pdf: 260280 bytes, checksum: f287c562e46cbb8512f0d04de04dec90 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Objetivo: O objetivo do presente estudo foi comparar as angulações dos bráquetes metálicos pré-ajustados da prescrição Roth de incisivos centrais e caninos superiores esquerdos. Materiais e Método: Para o estudo foram selecionados 10 bráquetes, de três marcas disponíveis no mercado: GAC, Forestadent e Morelli. Foram confeccionadas duas matrizes para permitir o posicionamento padronizado dos dentes e bráquetes. A captura das imagens foi realizada a partir de fotografia orto-radial padronizada, por meio de máquina fotográfica digital, exportadas e mensuradas com o programa Image J. Resultados: Os resultados foram submetidos à análise estatística por meio da Análise de Variância (ANOVA), seguido pelo teste Tukey ao nível de significância de 5%. Os bráquetes dos incisivos centrais superiores esquerdos mostraram diferenças estatisticamente significantes entre os seguintes grupos: MOR1 em relação ao GAC1; e FOR1 em relação ao GAC1. Nos caninos superiores esquerdos as diferenças estatisticamente significantes foram entre os grupos: MOR3 em relação ao GAC3; e MOR3 em relação ao FOR3. Conclusão: Com base nos resultados pode-se concluir que, a despeito da mesma denominação para a prescrição, entre marcas diferentes, as angulações não são iguais / Objective: The aim of this study was to compare the slot angulations of the pre-adjusted Roth prescription metallic brackets of left central maxillary incisors and left maxillary canines. Materials and Method: Ten brackets of three commercial brands were selected for this study: GAC, Forestadent and Morelli. Two individual metal matrix for brackets and tooth positioning were made for each teeth group. The captured images were made from standardized photography ortho-radial through digital camera, exported and measured with the software Image J. Results: One-way ANOVA and Tukey statistical analysis at 5% of significance level were performed. The results showed statistically significant differences between the brackets of the left maxillary central incisors between MOR1 and GAC1 groups, and between FOR1 and GAC1 groups. The data of left maxillary canines were statistically significant between MOR3 and GAC3 groups, and between MOR3 and FOR3. Conclusion: At basis of these results, it was possible conclude that despite the same prescription name of different brands, the angulations are different
22

Analise eletromiografica dos musculos obsiculares da boca e mentoniano em jovens portadores de maloclusão classe II, divisão 1 de angle tratados com aparelho bionator de balters

Baggio, Valeria Maria 17 February 1997 (has links)
Orientador: Fausto Berzin / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-22T01:45:21Z (GMT). No. of bitstreams: 1 Baggio_ValeriaMaria_M.pdf: 3528711 bytes, checksum: bdd20b5929b5f4e20b0b684e7fe2036c (MD5) Previous issue date: 1997 / Resumo: Os níveis de atividade eletromiográfica dos músculos orbiculares da boca ( segmentos superior e inferior) e mentoniano, foram verificados em oclusão habitual e durante a deglutição de saliva, em quatro crianças, com idade entre 10 e 12 anos, todas portadoras de maloclusão classe 11, divisão 1 de Angle, que receberam tratamento ortopédico funcional com o aparelho Bionator. Os exames elétromiográficos foram realizados sem e com o aparelho na cavidade bucal em diferentes períodos: 1a hora, 1a semana, 1° mês, 3° mês, e 6° mês. Os resultados obtidos foram submetidos à análise de variância e a distribuição de frequências baseadas na escala de níveis de intensidade em microvolts ( IlV), segundo Basmajian. Também foi feito o teste de Tukey para comparação de médias duas a duas. Concluiu-se que: há diferença no funcionamento dos músculos orbiculares superior e inferior da boca e mentoniano entre os indivíduos portadores de maloclusão classe 11, divisão 1 com lábios incompetentes, sendo que os músculos orbicular inferior e mentoniano, tem uma participação mais efetiva em relação ao superior tanto em oclusão habitual quanto em deglutição com saliva; o uso do aparelho Bionator diminuí o potencial de ação dos músculos orbiculares superior e inferior da boca e mentoniano, durante a oclusão habitual e no movimento de deglutição de saliva; os músculos orbiculares superior e inferior da boca funcionam independentemente durante a oclusão habitual, e deglutição, nos pacientes com ou sem o aparelho Bionator e portadores de maloclusão classe 11, divisão 1 de Angle / Abstract: Not informed. / Mestrado / Fisiologia e Biofisica do Sistema Estomatognatico / Mestre em Ciências
23

Resistencia ao cisalhamento de braquetes fixados com resinas polimerizadas por diferentes tipos de ativação

Guedes-Pinto, Eduardo 27 November 1997 (has links)
Orientador: Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-23T01:37:33Z (GMT). No. of bitstreams: 1 Guedes-Pinto_Eduardo_M.pdf: 2855830 bytes, checksum: ffca1786148a3514f02f16d72b6577e2 (MD5) Previous issue date: 1997 / Resumo: A proposta deste estudo foi avaliar a resistência ao cisalhamento de três materiais de colagem, polimerizados por diferentes sistemas de ativação. Foram utilizados 60 pré-molares humanos, extraídos com finalidade de tratamento ortodôntico. As faces vestibulares foram condicionadas com ácido fosfórico a 37% durante 30 segundos e os bráquetes fixados ao esmalte dentário com as . resinas Concise Ortodôntico (3M), Z-100 (3M) e cimento resinoso Dual (3M). Após a fixação dos bráquetes metálicos, os corpos-de-prova foram submetidos ao teste de cisalhamento 10 minutos e 24 horas após as colagens. Os resultados submetidos à análise estatística mostraram que houve diferença estatisticamente significante entre os três tipos de resina para os dois períodos de tempo de armazenamento. O sistema de colagem mais resistente foi promovido pelo Concise Ortodôntico, seguido pela resina fotoativada Z-100, e o menos resistente foi o cimento resinoso Dual. O tempo de armazenamento foi estatisticamente significante, pois representou aumento na resistência ao cisalhamento nos três tipos de materiais, provavelmente, devido à contínua conversão dos radicais livres / Abstract: The purpose of this study was to evaluate the shear bond strengths of three bonding materiaIs, activated by different systems. Sixty human premolars, extracted for orthodontic reasons, were used. Vestibular faces were etched for 30 seconds with 37% phosphoric acid gel and brackets were bonded to enamel surface using Concise chemically cured adhesive (3M), Z-100 light-cured adhesive (3M) and Dual cemerit resin (3M). After the bonding of metal brackets, specimens were tested and the shear stress at bond failure was recorded at 10 minutes and 24 hours. Results submitted to statistical analysis demonstrated a statistically significant difference in shear bond strengths among the three resins for both periods of storage. The most resistant bonding system was the Concise group, followed by the light-cured Z-100 and the less resistant Dual cement resin. The storage was statistically significant by increasing the shear bond strengths of the three materiaIs, probably because of the continue conversion / Mestrado / Ortodontia / Mestre em Ciências
24

Estudo eletromiografico dos musculos orbiculares da boca e mentoniano, em portadores de maloclusão classe II, divisão 1 de Angle tratados com aparelhos ortopedico de Bimler

Teixeira, Luis Fernando Lorenzi 14 August 2018 (has links)
Orientador: Fausto Berzin / Dissertação (mestrado) - Universidade Estadual de Campinas . Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-14T20:07:46Z (GMT). No. of bitstreams: 1 Teixeira_LuisFernandoLorenzi_M.pdf: 2824595 bytes, checksum: 15811f9b54de270d9a55308913ca2f5f (MD5) Previous issue date: 1997 / Resumo: Analisou-se o comportamento eletromiográfico dos músculos orbiculares superior e inferior da boca, porção medial e mentoniano em indivíduos jovens portadores de maloclusão Classe" divisão 1 de Angle com e sem o uso do aparelho ortopédíco funcional de BIMLER. Para tanto foram selecionados 5 pacientes sendo 1 do sexo masculino e 4 do sexo feminino com idade variando entre 10 e 12 anos. As atividades eletromiográficas destes músculos foram feitas em oclusão habitual e durante a deglutição de saliva nos perfodos de 18 hora, 1 semana, 1 mês, 3 meses e 6 meses. Os dados obtidos foram submetidos à análise de variâncía e para a comparação das médias duas a duas foi usado o teste de Tukey. Foram feitas também distribuição de frequências baseadas na escala de níveis de intensidade em microvolts segundo BASMAJIAN ( 1974 ). Os resultados revelaram que, existem diferenças no foncionamento dos músculos orbiculares da boca, porção medial, segmento superior e inferior entre os indivíduos classe li, divisão 1 de Angle durante o uso do aparelho; o segmento inferior tem uma participação mais efetiva em relação ao músculo orbicular superior, tanto em oclusão habitual quanto em deglutiçAo de saliva; durante a deglutlção de saliva os pacientes apresentaram uma atividade muito forte dos músculos mentoniano e segmento Inferior do orblcular da boca. Os músculos estudados revelaram, que em oclusão habitual e com o aparelho, as suas atividades- elétricas aumentam no 1° mês e diminuem significativamente no 3° e 6° mês de uso. Os pacientes sem o uso do aparelho funcional de BIMLER sempre mostraram que os potenciais de ação são menores que aqueles verificados com o aparelho, em todos os períodos estudados. Existe uma tendência de adaptação da atividade elétrica dos músculos peribucais ( orbiculares superior e inferior e mentoniano ) após o 6° mês do uso do aparelho funcional de BIMLER. / Abstract: Analysis of eletromiographic function of the mouth superior and inferior orbicular muscles, middle portion and mentonian in young patients with malocclusion class li, division 1 according to Angle with and without an ortopedic functional device of BIMLER. For This purpose 5 patients were selected, 1 male and 4 female with ages between 10 and 12. Muscular eletromiography activities were measured in usual oclussion and while swallowing saliva in the periods of 1 day, 1 week, 1 month, 3 months and 6 months. Data were submitted to varation analysis and results compared two by two according to Tukey. Iso the frequency distribution based in a intensity levels scale in microvolts according to Basmajian (, 1974 ) was made. Results showed significant differents in the activity of moutt1 orbicular muscle, middle portion, superior and inferior segments among the patients class 11, division 1 according to Angle while wearing the device, the inferior segment has a more effective function in relation to the superior orbicular muscle, as in usual occlusion as while swallowing saliva; in this period patients showed a very strong mentonian muscle and inferior segment of mouth orbicular activity. The studied muscles showed that in usual occlusion and with the device, electrial activltjes increase in the first month and decrease a lot in the 3rd and 6th month of use. Patients IIÍthout the BIMLER functional device showed action potentials smaller tha" the ones with the device, in ali the periods studied. There is a tendency to adapt the electrial activity from peribucal muscles ( superior and inferior o,picular and mentonian ) after the 6th month of use of the BIMLER functional device. / Mestrado / Fisiologia e Biofisica do Sistema Estomatognatico / Mestre em Ciências
25

Resistencia a antimicrobianos de microrganismos colhidos em artigos e equipamentos odontologicos

Motta, Rogério Heládio Lopes 05 February 2002 (has links)
Orientador: Thales Rocha de Mattos Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-01T10:31:26Z (GMT). No. of bitstreams: 1 Motta_RogerioHeladioLopes_M.pdf: 3737116 bytes, checksum: 4b2776a6fb8058f1adbf5dcebf1c2408 (MD5) Previous issue date: 2002 / Resumo: O correto uso de materiais esterilizados e barreiras de proteção são essenciais para o tratamento odontológico seguro, tanto para o paciente como para o cirurgião-dentista, diminuindo os riscos de contaminação cruzada. o objetivo deste trabalho foi quantificar a prevalênciade bactérias no ambiente da Clínica Odontológica da Faculdade de Odontologia de Piracicaba - UNICAMP. Foram realizadas colheitas de bactérias em diferentes locaisda Clínica utilizando-se swabs esterilizados, sendo colhidas amostras dos botões das cadeiras odontológicas, canhões de raio-X, luvas de procedimentos, maçanetas da porta de entrada da clínica, alças dos refletores, seringas tríplices e teclas "enter" dos computadores. As amostras foram colocadas em Placas de Petri contendo BHI e encubadas a 37° C, por 24 horas, assim como a 37°C, com 10% CO2, por 24 horas Os períodos de colheitas foram: antes, durante e após o término dos atendimentos da clínica. Foram contadas as unidades formadoras de colônias (ufc), sendo que a identificação presuntiva foi realizada utilizando-se o método de coloração de GRAM. A identificação das espécies foi feita através de testes bioquímicos. As bactérias colhidas foram submetidas ao teste de suscetibilidade antimicrobiana em agar, utilizando-se doze discos de antibióticos: ampicilina/10µg (amp), amoxicilina/10µg (amox), azitromicina/15µg (azi), claritromicina/15µg (cla), eritromicina/15µg (eri), cefadroxil/10µg (cef), clindamicina/2µg (clin), penicilina G/10u (pen), amoxicilina/20µg + ácido clavulânico/10µg (amox+cla), cloranfenico/30µg (cio), oxacilina 1µg (oxa) e vancomicina 30µg (van) . As porcentagens de resistência aos antimicrobianostestados foram: amp (62%), amox (68%), azi (35%), clari (58%), eri (42%), cef (56%), clin (51%), pen (71%), amox+ cla (47%), cio (31%), oxa (11%) e van (0%). Os resultados mostraram que as bactérias mais prevalentes foram os Streptococcus do grupo viridans, seguidas por Staphy/ococcus epidermidis. O botão de acionamento de cadeira foi o local com maior contaminação.O maior número de bactérias foi encontrado durante as atividades clínicas, independente da situação clínica analisada. Com os resultados do trabalho, podemos concluir que: 1) A atividade clínica aumenta a contaminação dos artigos e equipamentos odontológicos; 2) As bactérias encontradas mostraram alta porcentagem de resistência aos antibióticos testados; 3) Streptococcus do grupo viridans e Staphy/ococcus epidermidis foram os microrganismos mais encontrados / Abstract: Nowadays patients' infectious diseases mean serious risks to dentistry professionals. Thus, correct use of sterilized materiais, and self-protection equipment is essential. Bioaerosolsare an important considerationfor infection control and occupational health, since infectious agents could be transmitted via aerosols to patients or staff in the confines of the dental unit. The aim of this study was to identify microorganisms on dental equipment in the undergraduate clinic of Piracicaba Dentistry School. Also, antibiotic susceptibility tests were carried out against ali collected microorganisms. Microorganisms were collected from push buttons of dental chairs, air-water syringes, X ray device, gloves, computer keys, doorknobs, reflector handle, and lobby chairs by using sterilized swabs. They were inoculated on BHI agar, and incubated at 37°Cj24h. Ali microorganisms were collected in three different periods, before, during, and after clinical procedures. After counting, microorganisms were classified using Gram staining. Antibiotic susceptibility tests were assayed using commercial paper discs on Mueller-Hinton agar with 5% sheep-blood. Microorganisms were Gram+ cocci (67%), Gram+ bacilli(26%), Gram- cocci (5%), and others (2%). Rate of resistant strains was ampicillin/l0µg (62%), amoxicillin/l0µg (68%), azithromycin/15µg (35%), clarithromycin/15µg (58%), erythromycin/15µg (42%), cefadroxil/l0µg (56%), clindamycin/2µg (51%), penicillin/l0µ (71%), amoxicillin/20µg+clavulanic acid/10µg (47%), chloramphenicol/ 30µg (31%), oxacillin (11%)and vancomycin (0%). Push buttons of dental chairs were the most contaminated (p<0,05),and S.viridans were the most prevalent microorganisms. The highest number of microorganisms (p<0,05) was found during clinical procedures. We concluded that: increases environmental contamination;2) environmental microorganisms show high resistance rate against common antibiotics;3) S. viridans and S. epidermidis are the most common environmental microorganism / Mestrado / Farmacologia, Anestesiologia e Terapeutica / Mestre em Odontologia
26

Determinação da rugosidade, força de deslizamento, coeficiente e resistencia de atrito entre braquetes e fios ortodonticos

Secco, Angelo Stefano 25 July 2018 (has links)
Orientador: Mario Fernando de Goes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-25T18:54:50Z (GMT). No. of bitstreams: 1 Secco_AngeloStefano_D.pdf: 5008331 bytes, checksum: edd9d70da37852140146362ca5b4758a (MD5) Previous issue date: 1999 / Resumo: Considerando a falta de informações a respeito da força de deslizamento e 1 de atrito quando utiliza-se a mecânica de deslize com materiais de fabricação nacional, este trabalho foi desenvolvido com o objetivo de determinar a magnitude da força necessária para que ocorra o deslizamento do bráquete no fio, assim como determinar o valor da força de atrito, o percentual da força despendida com o atrito, o efeito da espessura dos fios na força de atrito, o coeficiente de atrito entre bráquetes e os fios, além de comparar a rugosidade do fio nacional com a do fio importado. Foi utilizado um sistema que simula a situação na qual os dentes inclinam suavemente até criar pontos de contato duplos e opostos entre a canaleta dos bráquetes e o fio. O sistema gerou uma tensão de 100g no centro de resistência a 10 mm da canaleta do bráquete, agindo no sentido oposto ao da força aplicada para mover o dente. Foram avaliadas 3 marcas de fios e bráquetes: duas nacionais - Tecnident e Morelli e uma importada - Dentaurum, Alemanha. Foram utilizados bráquetes metálicos de canaleta 0,022" e três : espessuras de fios 0,016x 0,022", 0,018x0,025" e o 0,021x0,025". Os testes foram realizados em uma máquina de ensaios Instron a uma velocidade de : 5mm/min. Os resultados apresentaram as seguintes médias de força de deslizamento para os fios Tecnident (198g) e Morefli (199g); estes resultados foram maiores e diferiram ao nível de significância de 5% da força requerida para deslizar o bráquete no fio importado Dentaurum, (178g). A variação da espessura dos arcos não interferiu significativamente na força de deslizamento assim como na força de atrito. A força de atrito desenvolvida pelos materiais nacionais Tecnident (98g) e Morelli (99g) foi maior e diferiu ao nível de significância de 5% da desenvolvida para o importado Dentaurum (78g). O percentual médio de força dissipada pelo atrito entre o bráquete e o fio ortodôntico durante o deslizamento foi de aproximadamente 49,8% para o conjunto bráquetes/arcos nacionais e 44,0% para o importado. Essa diferença foi significativa ao nível de 5% de significância. O material da marca Tecnident apresentou o maior coeficiente de atrito (0,164534); no entanto, a Morelli (0,150190) não diferiu estatisticamente da Dentaurum, que apresentou o menor coeficiente de atrito (0,147943). A rugosidade média dos fios da Tecnident foi da ordem de 0,15 um, aproximadamente 50% mais rugosos que os valores encontrados para os fios da marca Morelli 0,07u.m e da Dentaurum 0,07 j,m . Os fabricantes nacionais de bráquetes e fios ortodônticos devem rever o processo da fabricação de seus produtos para melhorar suas propriedades e características / Abstract: An appliance was constructed to simulate tooth movement in a previously aligned arch relative to bracket slot Nevertheless, when tooth was translated to siding mechanics, the crown was moved before the root, resulting in bracket tapping and angulation relative to the arch wire, making the arch contact the bracket two opposite points, creating friction. Regarding the lack of information about this situation using national manufactured materials, we developed the present study in order to determine: the force magnitude to occur bracket sliding, the frictional force \falues, the percentage of force dispersed by the friction, the effect of archwire \j/idth in frictional force, the coefficient of friction between brackets/archwires; and p compare the national and international archwires roughness. The system used simulated the clinical situation which slightly teeth tipping created two opposite joints contact between bracket slot and archwire. The system created a tension of 100g in the center of resistance from 10 mm to the bracket slot, acting in opposite side of the applied force to move the tooth. Three different arches and brackets ijjnds were evaluated, two national (Tecnident and Morelli) and one international (JDentaurum, from Germany). Stainless steel brackets slot of 0.022" and three archwires width were used (0.016 x 0.022", 0.018 x 0.025" and 0.021 x 0.025"). The tests were realized with an Instron testing machine moving at a speed of 5 ijnm/min. Results showed that mean force required to conduct brackets along national arches - Tecnident (198g) and Morelli (199g) - were higher and had Significant difference at 5% level to international one - Dentaurum (178g). The change in arches width did not interfere significantly both in sliding and frictional force. Frictional force developed by national materials Tecnident (98g) and Morelli (99g), were higher than international Dentaurum (78g), which was different statistically at 5% level. The mean force dispersed by friction between bracket and archwire during sliding was 49,8% to the national bracket/arch combination approximately, and 44% to the international one. This difference was significant at 5% level. National material Tecnident presented the highest frictional coefficient (0.164534). National material Morelli (0.150190) was not significant statistically relative to Dentaurum (0.1479430), which showed the lowest frictional coefficient. The average roughness of Tecnident arch was 0.15 urn approximately 50% more roughness than values found to Morelli (0.7 urn) and Dentaurum (0.7 jj.m) arches, in which there were not significant differences statistically (p<0.05) between roughness values / Doutorado / Doutor em Materiais Dentários
27

Contribuição ao projeto de bomba centrifuga de sangue

Motta, Gastão Dias 07 August 1991 (has links)
Orientador: Antonio Celso Fonseca de Arruda / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-14T00:30:18Z (GMT). No. of bitstreams: 1 Motta_GastaoDias_M.pdf: 5283386 bytes, checksum: 30a6f3b20fbf536c6b10ef0f70cb9e20 (MD5) Previous issue date: 1991 / Resumo: Este trabalho tem como objetivo basico contribuir para o desenvolvimento de uma bomba centrifuga de sangue funcionando sob o principio do arrasto viscoso entre uma ou mais superficies lisas rotativas e o sangue. A sua elaboração pode ser dividida numa parte experimental e numa parte teorica, as quais foram desenvolvidas de maneira simultanea mas absolutamente independentes entre...Observação: O resumo, na íntegra poderá ser visualizado no texto completo da tese digital / Abstract: The basic aim of this research is to contribute to the development of a centrifugal blood pump based on the viscous shear-force between one or more rotating smooth surfaces and the blood. This investigation has both an experimental part and a theoretical analysis, which have been simultaneously developed as absolutelly independent works...Note: The complete abstract is available with the full electronic digital thesis or dissertations / Mestrado / Mestre em Engenharia Mecânica
28

Analisador de desfibriladores/cardioversores

Nohama, Percy 31 January 1992 (has links)
Orientador: Maria Adelia Collier Farias / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-14T01:52:04Z (GMT). No. of bitstreams: 1 Nohama_Percy_M.pdf: 20926581 bytes, checksum: feaa301892b4c8844808a93bf5f336a7 (MD5) Previous issue date: 1992 / Resumo: A manutenção efetiva de equipamentos médicos, tais como desfibriladores e cardioversores, requer manutenção preventiva e corretiva que, em muitos casos, precisa ser realizada próxima à unidade hospitalar onde os equipamentos são utilizados. Desenvolveu-se um Analisador de desfibriladores/cardioversores analógico-digital, que atende aos requisitos de um instrumento de calibração, a um custo relativamente baixo. O Analisador é portátil e auto-suficiente (alimentado por baterias comuns). Cuidados especiais foram tomados para evitar perigos de choque elétrico (saída para osciloscópio isolada opticamente) ... Observação: O resumo, na íntegra, poderá ser visualizado no texto completo da tese digital / Abstract: Effective maintenance of medical devices, such as defibrillators and cardioverters, requires preventive maintenance and repair, which should be carried out in manu instances near the hospital unit where the devices are being used. It was developed an analogical-digital defibrillator/cardioverter analyzer, which fulfills the requirements of a calibrating equipment, at a relatively low cost. The analyzer is powered by ordinary batteries, it is self-sufficient, portable, and special care was taken to avoid shock hazards (optically isolated output to oscilloscope) ... Note: The complete abstract is available with the full electronic digital thesis or dissertations / Mestrado / Mestre em Engenharia Elétrica
29

Avaliação da padronização de agulhas anestesicas odontologicas comercializadas no Brasil

Girotto, Marcos Antonio 18 August 1998 (has links)
Orientador: Maria Cristina Volpato / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-24T06:58:33Z (GMT). No. of bitstreams: 1 Girotto_MarcosAntonio_M.pdf: 2174892 bytes, checksum: f96234f0323f7f96124c67ae1f3d9dad (MD5) Previous issue date: 1998 / Resumo: Dada a inexistência de uma normatização para a produção de agulhas anestésicas odontológicas descartáveis no Brasil, o objetivo deste trabalho foi avaliar o grau de padronização dessas agulhas comercializadas no país no segundo semestre de 1997, a saber: longas - BD, Ibras e Nipro; Curtas ¬BD, Ibras, Injecta, Misawa, Monoject, Nipro, Terumo e Unoject. Para cada teste foram utilizadas 10 agulhas de cada marca e tamanho, escolhidas ao acaso a partir da embalagem original. Foram avaliados neste estudo as medidas das agulhas quanto ao comprimento da cânula (C1), da parte que perfura o tubete (C2) e da porção que permanece no interior do adaptador plástico (C3) e diâmetros externo (DE) e interno (DI), a resistência à corrosão da cânula e as informações da embalagem (caixa e protetor), bem como o grau de deflexão após imersão em hidrocolóide irreversível (alginato). Os resultados foram submetidos à análise e,statística, sendo aplicados os testes de Tukey-kramer-HSD ou Kruskal¬Wallis, conforme os dados. Os resultados obtidos foram comparados com as normas internacional (ISO), americana (ANSI/ADA) e francesa (NF). Para as medidas C1, C2, C3 e DI houve variação tanto para as agulhas curtas quanto para as agulhas longas, não havendo uma marca que estivesse de acordo com uma das normas para todas as medidas. O DE foi bastante uniforme, com todas as marcas em conformidade com a ANSI/ADA e NF. O coeficiente de deflexão mostrou não haver diferença estatisticamente significante entre todas as marcas, revelando ainda não haver diferenças entre os calibres 30 G e 27 G. Todas as agulhas atingiram as especificações do teste de corrosão. Algumas embalagens mostraram conteúdo de informação incompleto, com uma marca sendo vendida sem prazo de validade. Alguns protetores não permitiam identificar a violação do lacre quando isto ocorria. Conclui-se que: a) nenhuma marca estava de acordo com qualquer da normas para todas as medidas; b) o aço utilizado é compatível com o fim a que se destina; c) as informações da embalagem e o lacre protetor são insuficientes para algumas marcas; d) a deflexão não tem correlação direta com o calibre da agulha; e) há necessidade de se estabelecer normas brasileiras para regulamentar a produção e venda de agulhas odontológicas no país / Abstract: The purpose of this paper was to evaluate the standardization of sterile, single use dental injection needles marketed in Brazil in the second semester of 1997, as this country does not have an official specification for the production of this material. Ten needles of each trade mark (Iong: BD, Ibras and Nipro - short: BD, Ibras, Nipro, Injecta, Misawa, Monoject, Terumo and Unoject) were randomily selected and used for each testo It was evaluated the dimensions of effective needle length (C1), butt end length (C2), socket depth (C3), outside diameter (OD) and inside diameter (ID), the corrosion resistance of the cannula, the information printed in the delivery package and the unit delivery package, as well as the defletion of the cannula in hydrocolloid. The results were analised by Tuckey-Kramer or Kruskal-Wallis testo Data were compared to the international standard (ISO), American specification no. 54 (ANSIj ADA) and French standard (FS). There were great variation for C1, C2, C3 and ID, and no trade mark fitted in any of the standards for ali the dimensions. The outside diameter showed very little variation with ali the trade marks according to ANSIj ADA and FS. Ali the needles withstood the corrosion testo Some trade marks had incomplete information in the delivery package and one had no final safe date for use. Some of the unit delivery package, once opened, did not show clear evidence of having been opened. There were no statistically significant difference in the defletion coefficient among the trade marks and the 27 and 30 gauge needles. It was concluded that: a) no trade mark met any of the standards for ali the dimensions; b) as seen 'in the corrosion test, ali of the needles were made of stainless steel compatible with the proposed use; c) the information in the delivery package and unit delivery package are insuficient; d) there was no correlation between the outside diameter and the defletion of the cannula, and e) there is an urgent necessity of a Brazilian specification for single use dental injection needles / Mestrado / Farmacologia / Mestre em Ciências
30

Dispositivos de microondas utilizando linhas de laminas

Villarroel Gonzalez, Carlos Humberto 16 July 2018 (has links)
Orientadores: Attilio Jose Giarola, Rui Fragassi Souza / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Campinas / Made available in DSpace on 2018-07-16T07:02:13Z (GMT). No. of bitstreams: 1 VillarroelGonzalez_CarlosHumberto_M.pdf: 2710677 bytes, checksum: ba644f42426d6fbaafb32b99fdb94045 (MD5) Previous issue date: 1985 / Resumo: Neste trabalho é apresentada uma análise téorico-prática das linhas de lâminas unilaterais. O comprimento de onda guiada é obtido mediante medições em laboratório. A impedância característica e a constante dielétrica efetiva são determinadas com base num método desenvolvido a partir da Teoria dos Guias de Ondas com Saliências e nas medidas dos comprimentos de onda guiada. Os resultados obtidos são comparados com aqueles obtidos com a Teoria da Linha de Transmissão Equivalente no Domínio Espectral da Transformação de Fourier; Observam-se algumas diferenças entre os resultados obtidos com ambos os métodos, que são atribuídos ao fato de que o modelo planar não considera a espessura finita da superfície metálica do circuito impresso nem a região de fixação finita do circuito impresso no guia de ondas metálico. Também apresentam-se dois projetos de atenuadores tipo paralelo, utilizando diodos PIN. Resultados coerentes com a teoria foram obtidos nestes casos. Algumas sugestões para a continuação de trabalhos nesta área são apresentadas / Abstract: In this work a theoretical-experimental analysis of unilateral fin lines is presented. The guided wavelength is obtained from adequate measurements in the laboratory. The characteristics impedances and the effective dielectric constants are determined using a method developed based on the theory of ridged waveguides and on the measured guided wavelengths. The obtained results are compared with those calculated from the equivalent transmission line in the spectral domain of the Fourier transform theory. The differences observed in this comparison are attributed to the approximation of the theoretical analysis that not only assumes metal fin's with negligible thicknesses but also neglects that there is a finite region for fixing the printed circuit in the metal waveguide. In addition, the design and construction of two parallel type attenuators using pin diodes is also discussed. The measured values are in agreement with those predicted from theory. Some suggestions for the continuation of work in this area are presented / Mestrado / Mestre em Engenharia Elétrica

Page generated in 0.2597 seconds