• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 527
  • 25
  • 25
  • 25
  • 23
  • 14
  • 13
  • 13
  • 12
  • 8
  • 6
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 537
  • 200
  • 161
  • 101
  • 91
  • 85
  • 81
  • 74
  • 71
  • 71
  • 70
  • 70
  • 69
  • 68
  • 67
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Efeitos dentoesqueléticos do tratamento da classe II utilizando o aparelho de Herbst associados à mecânica Straight-wire /

Ursi, Weber José da Silva. January 2008 (has links)
Banca: Rebeca Di Nicoló / Banca: Marcelo Fava de Moraes / Banca: Sebastião Interlandi / Banca: Jorge Abrão / Banca: Renato Rodrigues de Almeida / Resumo: O objetivo deste trabalho retrospectivo foi o de comparar os efeitos dentoesqueléticos, em pacientes apresentando maloclusão de Classe ll, da associação do aparelho de Herbst e aparelhos fixos Straight-wire, em duas populações de pacientes, uma brasileira (grupo Brasil) e outra norte-americana (grupo Michigan), utilizando como controle a amostra do University of Michigan Elementary and Secondary School Growth Study (UMGS). Para tanto, na amostra brasileira, foram selecionados 24 pacientes, sendo 12 do gênero masculino e 12 do feminino, com idades iniciais médias de 12 anos e 7 meses e idades finais médias de 15 anos e 3 meses, A amostra Michigan, foi tratada com um protocolo semelhante, constando de 28 pacientes sendo 21 do gênero feminino e 7 do masculino, com idades iniciais médias de 11 anos e 9 meses e finais médias de 14 anos e 4 meses. Os pacientes controle (N: 30) pertencem aos dados digitalizados do banco de dados do Center for Human Growth, e foram pareados com relação a sexo e idade com o grupo tratado Michigan. Para as avaliações cefalométricas, foram obtidas telerradiografias laterais antes do inicio do tratamento com o aparelho de Herbst e ao final do tratamento com os aparelhos fixos Straight-wire. A primeira comparação efetuada foi da amostra brasileira e o grupo controle controles. Verificou-se que os efeitos da associação do Aparelho de Herbst e aparelhos fixos Straight-wire provocaram efeitos positivos sobre o complexo dentofacial, com melhora na relação esquelética maxilomandibular, além de compensações dentoalveolares que contribuíram para a correção desta maloclusão. A segunda comparação, envolvendo os dois grupos tratados (grupos Brasil e Michigan), denotou que as alterações dentoesqueléticas foram praticamente idênticas. Estes resultados indicam claramente que no tratamento da maloclusão de Classe ll, a associação aparelho de Herbst.... / Abstract: This study compared the effect of the treatment protocol for correcting Class Il malocclusion using the Herbst appliance followed by full fixed Straigh-wire mechanics, in two populations, one Brazilian and one of North American origin As a untreated control sample the data from the University of Michigan Elementary and Secondary School Growth Study (UMGS) was used. Our sample was composed of 12 males and 12 females, with initial mean age of 12 years 7 months and final mean ages of 15 years and 3 months. The Michigan patients comprised 21 females and 7 males, with an initial mean age of 11 years and 9 months and final mean age of 14 years and 4 months. The control sample was paired in number, sex and age to the treated Michigan sample. ln both treated groups, lateral cephalometric radiographs were obtained before the Herbst appliance was cemented and at the end of the fixed appliance phase, The first comparison involved the Brazil group and the untreated controls, which demonstrated that the association of the Herbst appliance followed by fixed Straight-wire appliances provoked positive effects on the dentofacial complex, improving pre-existing maxillo-mandibular relationships, besides increasing dentoalveolar compensations which contributed to correct the malocclusion. The second comparison, involved the Brazl1ian and North-American patients treated with the same protocol. Although the pre-treatment comparison showed that the two groups were not similar in all aspects, they presented almost identical therapeutic modifications, which indicate that the effect of' treatment was very similar. These results point out that, in Class ll treatment, the combination of Herbst/Straight-wire mechanics produce consistent and systematic effects, correcting or minimizing possible skeletal imbalances
52

Alterações dentárias e esqueléticas decorrentes do tratamento da classe II, divisão 1

Souza, Maíra Massuia de January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:17Z (GMT). No. of bitstreams: 2 000399334-0.pdf: 1695765 bytes, checksum: 6f59773029d40433eae27686ee2c6259 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was to evaluate the effects of Class II division 1 treatment during facial growth on the maxilla, permanent maxillary first molars and central incisors, as well as the maxillomandibular relationship. The experimental sample comprised 38 Brazilian white patients (14 males and 24 females) with mean age of 11 years 2 months at treatment onset and 14 years and 5 months at the end of the treatment. The treatment consisted of cervical headgear associated to full fixed appliances. The control group included 39 Canadian individuals (25 males and 14 females) from the Burlington Growth Study, University of Toronto, Canada, treated only by space supervision or space maintenance. Each patient in the experimental group had a lateral cephalogram obtained at treatment onset (T1) and completion (T2). In control group, lateral cephalograms were available at the ages of 9, 12, 14, 16 years, providing data for comparison with the experimental group. In addition, it was made comparisons between initial and final values of experimental and control subjects, as well as comparison of variations in each group, by the Student’s t test. The results indicated restriction of forward displacement and clockwise rotation of the maxilla in both genders, and extrusion of permanent maxillary first molars and central incisors in males. Treatment also prevented the natural counterclockwise rotation of the mandible, especially in males and improved the maxillomandibular relationship. / O objetivo desse estudo foi avaliar os efeitos decorrentes do tratamento da Classe II, divisão 1 sobre a maxila; a posição dos primeiros molares e dos incisivos centrais permanentes superiores; e a relação maxilo-mandibular. O grupo experimental foi composto por 38 pacientes brasileiros brancos (14 meninos e 24 meninas) com idade média de 11 anos e 2 meses, no início, e 14 anos e 5 meses, ao final do tratamento, realizado com arco extrabucal tração cervical associado ao aparelho fixo, em ambas as arcadas. O grupo controle foi composto por 39 indivíduos canadenses (14 meninas e 25 meninos), participantes do Burlington Growth Study, Universidade de Toronto, Canadá, tratados somente por supervisão e manutenção de espaços. Cada paciente do grupo experimental apresentava uma telerradiografia inicial (T1) e uma final (T2). Na amostra controle, telerradiografias seriadas obtidas aos 9, 12, 14 e 16 anos forneceram os dados para a comparação com a amostra experimental. Na análise estatística, o teste t de Student proporcionou as comparações entre os valores iniciais e finais dos grupos experimental e controle, bem como a comparação entre as variações ocorridas em cada grupo. Os resultados indicaram que o tratamento realizado gerou restrição do deslocamento anterior e giro horário da maxila, em ambos os gêneros, provocou extrusão dos primeiros molares e dos incisivos centrais permanentes superiores, nos pacientes do gênero masculino, impediu a rotação anti-horária natural da mandíbula, principalmente no gênero masculino e promoveu a melhora da relação maxilo-mandibular.
53

Efeitos dento-esqueléticos decorrentes do tratamento da classe II, divisão 1 com aparelho extrabucal de tração alta

Silva, Liz Matzenbacher da January 2011 (has links)
Made available in DSpace on 2011-12-27T14:14:26Z (GMT). No. of bitstreams: 2 000433771-0.pdf: 1371003 bytes, checksum: 4371b440237c239d5982afb2c1f2c059 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was to evaluate the dento-skeletal effects of the headgear (HG) high traction. The total sample comprised 44 Brazilian individuals between entre 9 and 13 years old. The experimental group had twenty four individuals with Class II division 1 malocclusion treated by HG high traction (OrthoCap and conventional cap). The control group included 20 individuals with Class I malocclusion which was not treated during the period of the study. All individuals had two telerradiographies: initial (T1) and progress (T2), which was taken after 6 months of observation. Cephalometric points were digitalized into Dentofacial Planner Plus software to obtain the cephalometric measurements. In the statistical analysis Student’s t test was used to compare values of T1 and T2 in each group and for comparison of the differences (T1-T2) between groups. Results showed that treatment with HG high traction provoked restriction of forward growth of the maxilla (p<0. 05) and maxillo-mandibular relationship was improved, with reduction of the ANB (p<0,05). Superior molars moved toward distal with distal inclination (p<0. 05) e there was no significant change in the upper incisors. / No presente estudo avaliaram-se cefalometricamente os efeitos dento-esqueléticos do aparelho extra-bucal (AEB) de tração alta. Para tanto, foram avaliados 44 indivíduos brasileiros brancos e saudáveis, com idades entre 9 e 13 anos. O Grupo Experimental foi composto por 24 pacientes (idade média 11 ± 1,6 anos) com maloclusão de Classe II divisão 1, tratados com AEB de tração alta (OrthoCap e casquete tradicional). O grupo controle foi composto por 20 pacientes com maloclusão de Classe I que não receberam tratamento ortodôntico durante o período da avaliação. Todos indivíduos apresentavam telerradiografias de perfil ao início (T1) e após 6 meses (T2), em média. Pontos cefalométricos foram digitalizados no programa Dentofacial Planner Plus para obtenção das medidas cefalométricas. Na análise estatística foi utilizado o teste t de Student para comparação entre os valores de T1 e T2 dentro de cada grupo e para comparação das diferenças (T1-T2) entre os grupos. Os resultados demonstraram que o tratamento com AEB de tração alta provocou restrição do crescimento maxilar para anterior (p<0,05) e melhora na relação maxilo-mandibular, com redução do ANB (p<0,05). Os molares superiores apresentaram movimento distal com inclinação (p<0,05) e não houve alteração significativa nos incisivos superiores.
54

Reabilitação auditiva através de estimulação sonora por condução óssea

Cardoso, Carolina Costa 02 July 2014 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2014. / Submitted by Ana Cristina Barbosa da Silva (annabds@hotmail.com) on 2014-11-21T16:45:18Z No. of bitstreams: 1 2014_CarolinaCostaCardoso.pdf: 1194529 bytes, checksum: dc7cea8a26e81fada00b763a83606a56 (MD5) / Approved for entry into archive by Patrícia Nunes da Silva(patricia@bce.unb.br) on 2014-11-24T15:09:55Z (GMT) No. of bitstreams: 1 2014_CarolinaCostaCardoso.pdf: 1194529 bytes, checksum: dc7cea8a26e81fada00b763a83606a56 (MD5) / Made available in DSpace on 2014-11-24T15:09:55Z (GMT). No. of bitstreams: 1 2014_CarolinaCostaCardoso.pdf: 1194529 bytes, checksum: dc7cea8a26e81fada00b763a83606a56 (MD5) / Introdução: O Bone Anchored Hearing Aid (BAHA) é um sistema de condução óssea que propaga o som diretamente à orelha interna, transpondo a impedância da pele e do tecido subcutâneo. A indicação acontece para pacientes com perda auditiva mista, condutiva e neurossensorial unilateral que não se beneficiaram com o uso do Aparelho de Amplificação Sonora Individual convencional (AASI). Apesar dos benefícios do BAHA serem bem documentados internacionalmente, no Brasil ainda há escassez de estudos sobre o tema. Objetivo: Avaliar o processo de reabilitação auditiva de usuários do implante BAHA quanto aos seguintes aspectos: ganho audiológico, testes de percepção de fala e zumbido. Metodologia: Indivíduos de ambos os gêneros, portadores de perda auditiva usuários do sistema BAHA. A coleta de dados foi realizada da seguinte forma: carta convite para participação da pesquisa, termo de consentimento, audiometria tonal limiar em campo livre, audiometria de ganho funcional, testes de percepção de fala, Inventário de Handicap do Zumbido (THI) em formato aberto e Escala Visual Análoga (EVA).Todos realizados antes e após utilização do BAHA. Resultados: Foi constatado que os sujeitos obtiveram benefícios com o uso do BAHA. Em relação à acuidade auditiva, a diferença antes e depois do BAHA foi significativa. Nos testes de percepção de fala, não ocorreu diferença estatisticamente significativa. Em relação ao zumbido, no THI, 80% dos sujeitos apresentaram zumbido classificado como ligeiro após o uso do BAHA. Na Escala Visual Analóga, após o BAHA, 80% mudaram para categoria leve sendo significativo.Conclusão: Baseados nos resultados do presente estudo, podemos concluir que, nos sujeitos avaliados, houve melhora tanto com relação à percepção auditiva quanto ao zumbido. Assim, salientamos que aparelhos auditivos ancorados ao osso, com base no conceito de osteointegração, e o uso da audição por condução óssea podem beneficiar pacientes adultos e crianças, com perda auditiva condutiva, mista e neurossensorial. Também ressaltamos que a técnica cirúrgica é simples e os resultados são consistentes e favoráveis à melhora auditiva, bem como à qualidade de vida. ______________________________________________________________________________ ABSTRACT / Introduction: The Bone Anchored Hearing Aid (BAHA) is a bone conduction system that transmits the sound directly to the inner ear, surpassing the skin impedance and subcutaneous tissue. It is indicated for patients with mixed, conductive and unilateral sensorioneural hearing loss, who did not have benefits with conventional hearing aids (HA). Although the benefits of BAHA are well demonstrated internationally, in Brazil there is still a lack of studies on this area. Objective: To evaluate the auditory rehabilitation process in BAHA users in audiological, speech perception and tinnitus aspects. Methods: Individuals with hearing loss were evaluated before and after BAHA implantation. Participants were submitted to: pure tone audiometry in free field, functional gain audiometry, speech perception tests, Tinnitus Handicap Inventory (THI) in open format and Visual Analog Scale (VAS). Results: It was found that participants obtained benefits from the use of BAHA. The difference in participants’ performance before and after BAHA surgery was significant in terms of hearing acuity. There was no statistically significant difference in speech perception tests. Tinnitus evaluation showed that 80% of participants scored slight tinnitus severity in THI after using the BAHA. Eighty percent of participants classified their tinnitus as absent to mild in visual analog scale (VAS) after the BAHA surgery. Conclusion: Based on the results of this study, we can conclude that participants improved both the auditory perception and the tinnitus handicap. Bone anchored hearing aid, based on the concept of osseointegration, and the use of hearing through bone conduction can benefit children and adults with conductive, mixed and sensorioneural hearing loss. We emphasize that the BAHA system is implanted with a simple surgical technique and that the benefits are consistent and favorable to an improvement in hearing and in quality of life.
55

Cateter esofágico para medição de temperatura durante procedimento de ablação cardíaca por rádiofrequência (RF)

Sousa, Rui Alves de January 2009 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2009. / Submitted by Allan Wanick Motta (allan_wanick@hotmail.com) on 2010-04-23T14:35:56Z No. of bitstreams: 1 2009_RuiAlvesdeSousa.pdf: 637987 bytes, checksum: acdd9243f829ef4d74f8fc004e971ba4 (MD5) / Approved for entry into archive by Lucila Saraiva(lucilasaraiva1@gmail.com) on 2010-04-30T22:02:15Z (GMT) No. of bitstreams: 1 2009_RuiAlvesdeSousa.pdf: 637987 bytes, checksum: acdd9243f829ef4d74f8fc004e971ba4 (MD5) / Made available in DSpace on 2010-04-30T22:02:15Z (GMT). No. of bitstreams: 1 2009_RuiAlvesdeSousa.pdf: 637987 bytes, checksum: acdd9243f829ef4d74f8fc004e971ba4 (MD5) Previous issue date: 2009 / O trabalho visou abordar o problema de fístula atrio-esôfagica durante o procedimento de ablação por RF. Através de um modelo computacional em elementos finitos obtemos dados sobre o comportamento da temperatura ao longo da região entre átrio e esôfago e sua propagação durante o procedimento de ablação. Estes dados nos permitiram projetar o cateter esôfagico o que foi desenvolvido, este cateter tinha uma acurácia de 0,05 C com P< 0; 05 (ANOVA) variando de 25 C a 75 C. A busca por resultados mais acurados e precisos nos levou a desenvolver como complemento um equipamento para mensurar o tempo de relaxamento em tecidos. O equipamento desenvolvido obteve os seguintes resultados para agar gel: tempo de relaxamento de 4,69 segundos e difusitividade térmica de 1; 3679e��7 2,76e-9 m2=s, resultado 6 % divergente do cálculo teóricoof 1,4559e-7 m2=s. _______________________________________________________________________________________ ABSTRACT / The atrial-esophageal fistula is a potentially fatal complication of radiofrequency cardiac ablation. We developed a finite element model in order to determine the behavior of temperature along the region between the atrium and esophagus during the ablation procedure. The results of the model were used in order to design, build and test an esophageal catheter. The catheter accuracy was 0,05 C in the 25 C - 75 C range (p<0,05). In addition, we developed an instrument to measure the thermal relaxation time of agar a commonly used substance for the study of ablation procedures. The results showed that its thermal relaxation time and thermal diffusivity was of 4,69 seconds and 1; 3679e��7 2; 76e��9m2=s respectively.
56

Opinião dos pacientes cirúrgicos e conhecimento dos trabalhadores em centro de material e esterilização em relação aos artigos médico-hospitalares esterilizados

Freiberger, Mônica Fernandes 04 August 2006 (has links)
Dissertação (mestrado)-Universidade de Brasília, Faculdade de Ciências da Saúde, Convênio UNB/UNIR, 2006. / Submitted by samara castro (sammy_roberta7@hotmail.com) on 2010-11-07T22:39:10Z No. of bitstreams: 1 2006-Monica Fernandes Freiberger.pdf: 315824 bytes, checksum: 53333bd5100a20296e2a67352a791d01 (MD5) / Approved for entry into archive by Daniel Ribeiro(daniel@bce.unb.br) on 2010-11-10T23:26:27Z (GMT) No. of bitstreams: 1 2006-Monica Fernandes Freiberger.pdf: 315824 bytes, checksum: 53333bd5100a20296e2a67352a791d01 (MD5) / Made available in DSpace on 2010-11-10T23:26:27Z (GMT). No. of bitstreams: 1 2006-Monica Fernandes Freiberger.pdf: 315824 bytes, checksum: 53333bd5100a20296e2a67352a791d01 (MD5) / Este estudo objetivou a análise dos conceitos que envolvem a opinião dos pacientes cirúrgicos e conhecimento dos trabalhadores em centro de material e esterilização em relação aos artigos médico-hospitalares esterilizados como medida de prevenção da Infecção Hospitalar. Para tanto, foi realizado um estudo de caráter descritivo exploratório de abordagem quanti-qualitativa, onde os dados foram coletados utilizando-se um formulário estruturado contendo questões fechadas e abertas junto a 100 pacientes cirúrgicos em período pós-operatório mediato e 15 trabalhadores do Centro de Material e Esterilização de quatro hospitais do município de Cacoal-RO, no período compreendido entre Novembro e Dezembro de 2005. A estatística descritiva de significância e teste Qui-quadrado foi utilizado na análise dos resultados, os quais mostraram que dos 100 pacientes investigados, 80 apresentaram conceitos de conhecimento sobre esterilização, sendo que 71 participantes (88,8%) responderam preocupar-se com a qualidade da esterilização e 58 (72,5%) sabem o que é infecção hospitalar. Dos 15 profissionais do CME, 11 (73,3%) relataram não possuir competência para a realização da esterilização; 11 (73,3%) apontaram à falta de qualidade dos artigos médico-hospitalares devido a equipamentos inadequados e a inexistência de testes específicos para validação da esterilização. Percebe-se com isto que a opinião dos pacientes cirúrgicos e conhecimento dos trabalhadores em Centro de Material e Esterilização em relação aos artigos médico-hospitalares são insuficientes para minimizar as iatrogenias que estes artigos podem provocar, sem que os pacientes tomem ciência desta problemática, aumentando os riscos de contração de infecção hospitalar. Dessa maneira, o estudo oferecerá sua contribuição para o avanço do conhecimento na Enfermagem, pois disponibilizará algumas reflexões sobre atuação da equipe de saúde e de enfermagem contribuindo para a melhoria da qualidade da assistência prestada ao paciente cirúrgico. _________________________________________________________________________________ ABSTRACT / In this study it is aimed to analyze surgical patients concepts and knowledge about their worries concerning hospitalar medical equipments sterilization as Hospital Infectionmeasure. Searching this objective, it was choose a descriptive – exploratory study by a quanti-qualitative approach. The data wascoleckd by a structured form with open-ended questions with 100 surgical patients in mediate post-operative period, and 15 Sterilization Center Workers of four hospital in Cacoal-RO. The results was analyzed by descriptive significance statistic and indicates that 80 patients presented significant corrupts and knowledge about the equipment sterilization, 71 concerns the sterilization quality and 58 knows about hospitalar infections. Among the Sterilization Center workers, 11 ones related they don’t have competence for sterilization achievement, and other 11 about the equipment quality lack because inadequate equipments and material sterilization validating. Therefore it is possible to perceive that surgical patients knowledge and concepts about their worried of Hospitalar medical sterilized equipments is possibility to increase hospitalar Infections.
57

Estimador não invasivo de pressão arterial utilizando o tempo de transito de pulso

Villegas Sanchez, Marcelo Alejandro 21 August 2009 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2009. / Submitted by Jaqueline Ferreira de Souza (jaquefs.braz@gmail.com) on 2011-06-17T19:35:05Z No. of bitstreams: 1 2009_MarceloAlejandroVillegasSanchez.pdf: 5924186 bytes, checksum: f7eb16e6e716134fb68ac49de40d1359 (MD5) / Approved for entry into archive by Jaqueline Ferreira de Souza(jaquefs.braz@gmail.com) on 2011-06-17T19:35:34Z (GMT) No. of bitstreams: 1 2009_MarceloAlejandroVillegasSanchez.pdf: 5924186 bytes, checksum: f7eb16e6e716134fb68ac49de40d1359 (MD5) / Made available in DSpace on 2011-06-17T19:35:34Z (GMT). No. of bitstreams: 1 2009_MarceloAlejandroVillegasSanchez.pdf: 5924186 bytes, checksum: f7eb16e6e716134fb68ac49de40d1359 (MD5) / Métodos de monitoramento contínuos e controle não-invasivos de pressão arterial são muito desejados, especialmente para pacientes que precisam realizar o controle da pressão arterial quando estão em casa ou quando realizam uma atividade física. Hoje em dia, para medir pressão arterial, o método não invasivo de maior emprego é o esfignomanômetro o qual é pouco confortável para se realizar um controle contínuo. Uma solução para esse problema é a estimação da pressão arterial utilizando o Tempo de Trânsito de Pulso PTT. A presente dissertação de mestrado descreve os trabalhos realizados em um sistema de aquisição de sinais biomédicos e apresenta um algoritimo que avalia a aquisição de sinais ECG e PPG e ainda é capaz de recusar erros. Apresenta-se também um segundo algoritmo que permite estimar a pressão arterial sistólica. Estes algoritmos foram elavorados com o objetivo de serem empregados em um sistema embarcado com processador ARM9. _______________________________________________________________________________ ABSTRACT / Methods for continuous monitoring and non-invasive control of the arterial blood pressure are strongly desired, especially for patients who need to control their blood pressure at home or conducting a physical activity. Nowadays, in order to measure the blood pressure, the most popular non-invasive method is sphygmomanometer (cuff) , however it is uncomfortable to use it for continuous control. One possible solution to this problem is the estimation of the blood pressure using the Transit Time Pulse (PTT). This work describes several signal processing algorithms in a biomedical signal acquisition system and presents an mechanism that evaluates the acquisition of ECG and PPG signals along with an error detection tool. We also present a method that estimates the systolic blood pressure. All the proposed techniques were developed in order to be employed in an embedded system with an ARM9 processor.
58

Modelagem em alto nível do consumo de energia para sistema em chip em redes de sensores sem fio / High level modeling of energy consumption of system on chip in wireless sensor networks

Madureira, Heider Marconi Guedes 11 1900 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2011. / Submitted by Tania Milca Carvalho Malheiros (tania@bce.unb.br) on 2012-03-08T18:13:34Z No. of bitstreams: 1 2011_HeiderMarconiGuedesMadureira.pdf: 2654901 bytes, checksum: 1659f7f6ae84facba23cfa37524e51a9 (MD5) / Approved for entry into archive by Marília Freitas(marilia@bce.unb.br) on 2012-03-20T13:08:46Z (GMT) No. of bitstreams: 1 2011_HeiderMarconiGuedesMadureira.pdf: 2654901 bytes, checksum: 1659f7f6ae84facba23cfa37524e51a9 (MD5) / Made available in DSpace on 2012-03-20T13:08:46Z (GMT). No. of bitstreams: 1 2011_HeiderMarconiGuedesMadureira.pdf: 2654901 bytes, checksum: 1659f7f6ae84facba23cfa37524e51a9 (MD5) / Este trabalho apresenta a modelagem em nível de transações (TLM) do consumo de energia de um sistema em chip (SoC) para aplicação em redes de sensores sem fio. Os modelos desenvolvidos permitem a execução de software embarcado desenvolvido para o SoC em uma plataforma virtual tornando possível co-projeto hardware/software. A estratégia de modelagem descrita permite avaliar tanto o consumo de energia de cada componente de hardware dos nós quanto o consumo total de cada nó. O desenvolvimento do projeto foi realizado usando a linguagem de descrição de hardware SystemC em nível de transações. Foram desenvolvidos estudos de caso que o SoC isolado executa o algoritmo de criptografia AES, uma rede de sensores sem fio em estrela e uma rede de sensores sem fio com multihopping.Os resultados mostram a viabilidade de usar modelagem em alto nível para estimativa de consumo de energia e projeto de redes de sensores sem fio. ______________________________________________________________________________ ABSTRACT / This work describes the transction-level modeling of the energy consumption of a system on chip (SoC) for wireless sensor networks applications. The developed models allow the execution of the embedded software designed for the SoC in a virtual platform enabling hardware/software co-design. The modeling strategy described here allow the estimation of the energy consumption of each node’s hardware component as well as the total node consumption. The design was made using the hardware description language SystemC in transactionlevel. Case studies presenting an isolated SoC running the AES cryptography algorithm, a wireless sensor network in star topology and a wireless sensor network with multihop. The results show the viability of using high level modeling to estimate energy consumption and design wireless sensor networks.
59

A extrusão dentaria e a sua importancia na clinica odontologica

Ciruffo, Paulo Afonso Dimas Rios 26 April 1996 (has links)
Orientador: Antonio Wilson Sallum / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-21T07:12:04Z (GMT). No. of bitstreams: 1 Ciruffo_PauloAfonsoDimasRios_M.pdf: 5928166 bytes, checksum: f1fb3b50d096026136c797c75021d72f (MD5) Previous issue date: 1996 / Resumo: O presente trabalho tem por objetivo, verificar as alterações periodontais através de exames radiográficos periapicais milimetrados, dos dentes submetidos à extrusão ortodôntica, em relação às alterações da crista gengival e da crista óssea, de dentes portadores de fraturas radiculares, lesões cariosas, perfurações ao nível cervical da raiz, que dificultam a terapia periodontal, protética, endodôntica e restauradora. Foram usados na pesquisa 15 dentes, que foram submetidos à Extrusão Dentária, através o uso de Aparelho Fixo na técnica de Edgewise. A força ortodôntica aplicada foi de 20-30 gramas no primeiro dia, aos 15, 30, 45 e 60 dias do período ativo, sendo também avaliado as condições periodontais dos dentes vizinhos. Após o período ativo, foi colocado um arco seccionado passivo retangular 0.17"x 0,22" para a estabilização. A média do comprimento radicular dos dentes em função do tempo de tratamento, no primeiro dia, aos 15, 30, 45 e 60 dias foram 13,87; 12,23; 12,17; 11,57 e 11,13 mm, enquanto que a média da extrusão obtida foi de 2,73 mm. A relação das médias de recidiva aos 30 e 60 dias do período de contenção com a média aos 60 dias do período ativo foram de 0,04 e 0,26 mm. A cada dia de tratamento ativo, o nível da extrusão da raiz foi de 0,044 mm, já em relação a margem gengival e a margem do preparo houve um aumento de 0,047 mm e 0,045 mm para a distância entre a margem óssea e a margem do preparo. O coeficiente linear em relação ao comprimento radicular dos dentes vizinhos para cada dia de tratamento, foi de 0,003 mm. O teste "t" foi significativo ao nível de 1 % de probabilidade para todos os coeficientes de correlação indicando, que as variáveis são correlacionadas. Concluiu-se, que houve alteração milimétrica na crista alveolar e na crista gengival dos dentes submetidos à Extrusão Dentária, assim como também nos dentes vizinhos. O tempo médio de Extrusão foi de 47 dias / Abstract: The aim of this paper work is to verify the periodontal changes through the milimetered periapical radiograph of teeth submited to orthodontic extrusion, wich had root fractures, carries , and cervical root perforations,conditions that make the periodontal, prosthodontic, endodontic and dentistam therapy harder to perform. In this research 15 participants were treated, 10 of the feminine and 5 of the masculine sexo They were submited to dental extrusion using fixed appliance with the Edgewise Techinic. The ortodontic force applied was of 20-30 grams at 15, 30, 45 and 60 days of the active period where also the periodontal condutions of the neighbour teeths were checked. After the active period, a 0.17" x 0.22" retangular passive seccionaded arch was placed in order to estabilize the result. The average of patient root lengthening relation treatment time in the begining at the 15, 30, 45 and 60 days were 13,87, 12,23, 11,57 and 11.13 milimeter, although that average achieved extrusion was 2.73 milimeter. The relation average of relapse at the 30 and 60 days in the active period with the average by the 60 days in the active period were 0.04 milimeter and 0.26 milimeter. The each day of increased treatment, the root lengthening had decreased 0.044 milimeter, already in relation the gengival margin and the prepare margin there was a increase of 0.047 milimeter and 0.045 milimeter to distance between osseous margin and the prepare margin. The linear coeficient represented a increase very next of zero in root lengthening of neighbour teeth to each day the treatment having a increase this root lengthening of 0.003 milimeter. The test t was significative by the levei 1 % of probably to all the coeficient in the relation indicating that the changeable are correlated. Conclude that there was milimeter change in the alveolar ridge of submete tooth extrusion as toa in the neighbour teeth. The average time of extrusion was 47 days / Mestrado / Ortodontia / Mestre em Odontologia
60

Efeito de brocas para implantes sobre o tecido osseo : estudo histologico em cães

Couto Filho, Carlos Eduardo Gomes do, 1962- 23 July 2018 (has links)
Orientador: Luis Augusto Passeri / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-23T11:31:04Z (GMT). No. of bitstreams: 1 CoutoFilho_CarlosEduardoGomesdo_M.pdf: 4440845 bytes, checksum: 9f293372bb6de2d09bc9aee2f8bb3e69 (MD5) Previous issue date: 1998 / Resumo: o sucesso do tratamento, através da colocação de implantes, exige leitos receptores adequados, para que ocorra uma osseointegração ideal. O equipamento utilizado para a confecção destas cavidades deve ser o mais preciso possível, devendo promover cortes com paredes bastante regulares e sem áreas de necrose. Com o objetivo de avaliar histologicamente, o efeito das brocas para implantes sobre o tecido ósseo utilizou-se sete cães, confeccionando-se, na mandibula de cada um deles, orifícios para colocação de implantes, seguindo a seqüência de brocas sugerida pelos fabricantes dos sistemas Nobel Biocare, ImpJamed e 3i. Após a confecção das cavidades, removeu-se o fragmento ósseo, e executou-se cortes semi-seriados de 6 f.lIll, no sentido don longo eixo dos cortes, e coloração com hematoxilina e eosina. A avaliação microscópica mostrou cortes regulares com poucas áreas de necrose e esquírolas ósseas, evidenciando que a técnica utilizada foi adequada, atestando a qualidade das brocas / Abstract: The success of the treatment through the placement of osseointegrated implants will require appropriate cavities so it happen an ideal osseointegration. The equipment that was needed to make these cavities must be the most accurate promoting holes with uniform wall and without necrosls area. With intention to avaluate the histollogical effects of burs over the osseous tissue it was used eight dogs, made in the lower jaw holes to place the implants following the sequence of burs suggested by manufacturers After the holes were made the osseous fragments were removed and made semiseriate .incisions of 6 JlIIl following the long axis of the holes and stained with heinatoxiline and eosine A microscopic avaluation showed sharp incision, few necrosis area and bone fragments meaning that applied technique was adequated and proving the quality of the burs / Mestrado / Mestre em Odontologia

Page generated in 0.0415 seconds