• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1390
  • 317
  • 71
  • 52
  • 49
  • 22
  • 22
  • 22
  • 21
  • 17
  • 14
  • 14
  • 8
  • 8
  • 8
  • Tagged with
  • 2029
  • 808
  • 542
  • 368
  • 292
  • 208
  • 200
  • 166
  • 151
  • 146
  • 141
  • 135
  • 130
  • 122
  • 121
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
241

Análise de simulação de uso do Brise-Soleil como sistema de controle termal de uma fachada

Gomes, Diego de Miranda Mariath January 2018 (has links)
Submitted by Gisely Teixeira (gisely.teixeira@uniceub.br) on 2018-06-16T14:19:49Z No. of bitstreams: 1 51500353.pdf: 825277 bytes, checksum: c0a56c36defe2ac1db2657328abc32ff (MD5) / Made available in DSpace on 2018-06-16T14:19:49Z (GMT). No. of bitstreams: 1 51500353.pdf: 825277 bytes, checksum: c0a56c36defe2ac1db2657328abc32ff (MD5) Previous issue date: 2018 / O artigo simula a instalação de brise-soleil como sistema de controle termal de uma fachada em uma residência em Brasília, Distrito Federal. Levando-se em conta as características do cômodo e sua fachada oeste, foi escolhido o modelo de brise metálico retrátil. Os dados necessários para análise foram obtidos através do aplicativo para smartphone iCelsius e do equipamento portátil FLIR ONE. Os dados obtidos foram analisados apoiando-se em descrições técnicas obtidas pelo fabricante e a partir da bibliografia existente. Os resultados da simulação foram satisfatórios, uma vez que a utilização de brise-soleil como protetor solar diminui a temperatura do ambiente promovendo conforto térmico. Conclui-se que apesar do retorno financeiro pela substituição de aparelhos refrigeradores de ar por brise-soleil, não há garantia de satisfação total e descarte do uso desses aparelhos, uma vez que o conforto térmico é relativo para cada indivíduo, que pode desejar temperaturas ainda mais amenas.
242

Influência do tamanho da partícula, do jateamento prévio à sinterização e do envelhecimento na resistência mecânica de uma zircônia estabilizada por ítria /

Martins, Samira Branco. January 2018 (has links)
Orientador: Renata Garcia Fonseca / Resumo: Pouco se sabe sobre o efeito do jateamento pré-sinterização da zircônia na sua resistência mecânica, sob condições de envelhecimento. Este estudo avaliou a influência do tamanho da partícula, do momento do jateamento e do envelhecimento na resistência mecânica de uma zircônia estabilizada por ítria. Quatrocentos discos de uma zircônia estabilizada por ítria pré-sinterizados foram alocados como segue: sem jateamento; jateamento com partículas de óxido de alumínio (Al2O3) de 50 µm ou 120 µm antes (50/PRÉ ou 120/PRÉ) ou após (50/PÓS ou 120/PÓS) sua sinterização. Os discos foram não envelhecidos (24h) ou envelhecidos por: ciclagem mecânica (CM); envelhecimento hidrotérmico (EH) ou CM+EH, totalizando 20 grupos (n=20). Os espécimes foram submetidos ao teste de resistência à flexão biaxial (RFB) e, posteriormente, foram analisados fractograficamente. A análise de difração de raios-X (DRX) foi realizada em determinadas condições para caracterizar cristalograficamente o efeito do jateamento na zircônia. Os dados de RFB (MPa) foram analisados por ANOVA a 3 fatores e pós teste de Games Howell (α=0,05). Também foi realizada análise de Weibull. A RFB e a resistência característica (σ0) dos grupos 120/PÓS, envelhecidos ou não, foram significativamente maiores que as dos demais grupos jateados, e estatisticamente similares ou maiores que as dos respectivos grupos sem jateamento. Em contrapartida, o grupo 120/PRÉ/não envelhecido e todos os grupos 50/PRÉ apresentaram os menores valores. Em to... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Little is known about the effect of air-abrasion before zirconia sintering on its strength, under aging challenge. This study aimed to verify the influence of the airabrasion moment (before or after zirconia sintering), particle size (50 or 120 µm) and aging on the mechanical strength of a Y-TZP ceramic. Four hundred pre-sintered zirconia discs were allocated as follows: non-air-abraded; air-abraded with 50 µm or 120 µm Al2O3 particles before (50/BS or 120/BS) or after sintering (50/AS or 120/AS). The discs were non-aged (24h) or aged by: mechanical cycling (MC); hydrothermal aging (HA) or by both methods (MC+HA), totaling 20 groups (n=20). Specimens were subjected to biaxial flexural strength test (BFS). Fractographic analysis was performed to identify the fracture origin. The X-ray diffraction analysis (XRD) was performed under certain conditions to characterize the crystallographic effect of airabrasion on the zirconia. The BFS data (MPa) were analyzed by ANOVA and Games Howell post hoc test (α=.05). Weibull statistics was also applied. The BFS and the characteristic resistance (σ0) of the 120/AS groups, aged or not, were significantly higher than those of the other air-abraded groups, and statistically similar or higher than the respective groups without air-abrasion. In contrast, the 120/BS/non-aged group and all those 50/BS presented the lowest values. In all groups, the initial defect had its origin on the tensile stress side. Neither air-abrasion nor aging (except for 50/AS/MC+HA) reduced the zirconia reliability compared with the respective controls. Air-abrasion promotes an increase in the monoclinic phase content, while sintering zeroed this phase. Air-abrasion before zirconia sintering yields worse performance for BFS than after sintering, under aging challenges. The BFS and σ0 were strongly determined by the particle size and air-abrasion moment / Doutor
243

Comparativo entre biodieseis produzidos a partir de diferentes mat?rias-primas e rotas de produ??o e utilizados em motor estacion?rio / Comparison of biodiesels produced from different raw materials and production routes used in stationary engine

Lempek, Jo?o Ricardo Oliveira 29 March 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-07-27T17:51:14Z No. of bitstreams: 1 DIS_JOAO_RICARDO_O_LEMPEK_COMPLETO.pdf: 2298515 bytes, checksum: 1fee16fd37282b069aa0aa85971cd773 (MD5) / Made available in DSpace on 2016-07-27T17:51:15Z (GMT). No. of bitstreams: 1 DIS_JOAO_RICARDO_O_LEMPEK_COMPLETO.pdf: 2298515 bytes, checksum: 1fee16fd37282b069aa0aa85971cd773 (MD5) Previous issue date: 2016-03-29 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Funda??o de Amparo ? Pesquisa do Estado do Rio Grande do Sul - FAPERGS / This study aims to compare the use of different biodiesels produced from different raw materials and production routes in a stationary diesel cycle engine. Physical and chemical analyses were performed on biodiesels, their molecular structures were determined, as well as opacity, consumption and emissions in stationary engine used in motor-generator group were analyzed. In cooperation with CIENTEC - Foundation for Science and Technology of Rio Grande do Sul and Bianchini S.A Company, biodiesels were produced from soybean oil and tallow, with purity percentage according to ANP standard. In addition to the commercial diesel purchased at gas stations, consisting of 7% biodiesel already in its composition, it was used blends with 20%, 25%, 30% and 50% diesel-biodiesel, as well as pure biodiesel (100%). Tests were performed on a diesel stationary engine, Ruggerini, 191 model, with nominal power of 13 kW, instrumented with a gas analyzer and an opacimeter on the exhaust system. Gases such as nitrogen oxides (NOx), carbon dioxide (CO2), nitrogen dioxide (NO2), carbon monoxide (CO) and nitrogen monoxide (NO), as well as O2 (oxygen) and SO2 (sulfur dioxide) were analyzed, and the results were compared with theoretical works previously published. The results showed that the most favorable blend and showed a better behavior in terms of opacity was the methyl soybean B100; in relation to consumption, obtaining equal values, were the B20, B25 and B30 ethyl soybean and the behavior of the emissions who was more favorable was the soybean B25 by methyl route despite little difference with the other studied blends. / O presente trabalho objetiva comparar a utiliza??o de diferentes biodieseis obtidos a partir de diferentes mat?rias-primas e rotas de produ??o em um motor ciclo diesel. Foram realizadas an?lises abrangendo desde as caracter?sticas f?sico-qu?micas dos biodieseis e suas estruturas moleculares at? ensaios de opacidade, consumo e emiss?es de gases em motor estacion?rio empregado em grupo motor-gerador. Em parceria com a CIENTEC ? Funda??o de Ci?ncia e Tecnologia do Rio Grande do Sul e a empresa Bianchini S.A, foram obtidos os biodieseis produzidos a partir de ?leo de soja e banha de porco, com percentual de pureza de acordo com norma da ANP. Al?m do diesel comum adquirido em postos de combust?veis, constitu?do de 7% de biodiesel j? em sua composi??o, optou-se pela utiliza??o de misturas com 20%, 25%, 30% e 50% adicionado ao diesel, al?m do biodiesel puro (100%). Os ensaios foram realizados em um motor ciclo diesel da marca Ruggerini, modelo 191, com pot?ncia nominal de 13 kW, instrumentado com equipamento analisador de gases e de opacidade a fim de obter dados de emiss?es de gases de escapamento. Foram analisados gases como ?xidos de nitrog?nio (NOx), di?xido de carbono (CO2), di?xido de nitrog?nio (NO2), mon?xido de carbono (CO) e mon?xido de nitrog?nio (NO), al?m de O2 (oxig?nio) e SO2 (di?xido de enxofre) e os resultados comparados com referencial te?rico publicado anteriormente. Os resultados demonstraram que a mistura mais favor?vel e que apresentou o melhor comportamento em termos de opacidade foi o B100 de soja met?lico; em rela??o ao consumo, obtendo valores iguais, foram os B20, B25 e B30 de soja et?lica e para o comportamento das emiss?es o quem foi mais favor?vel foi o B25 de soja pela rota met?lica, apesar da pouca diferen?a com as outras misturas estudadas.
244

Turbulent air-flow and dispersion of pollutants in the atmosphere

Epstein, Mario January 1977 (has links)
This study is a contribution toward the understanding and prediction of turbulent dispersion of pollutants in the atmosphere. The main underlying assumption suggestion is that the Lagrangian autocorrelation RL used in computation of plume dispersion may be approximated by an Eulerian space-time correlation.
245

Geração, caracterização e aplicações das nanobolhas na remoção de poluentes aquosos e reúso de água por flotação

Etchepare, Ramiro Gonçalves January 2016 (has links)
O objetivo desta tese de doutorado foi desenvolver um novo método de geração de nanobolhas de ar (NBs) em meio aquoso via cavitação hidrodinâmica. Foram estudados os principais parâmetros envolvidos na formação e propriedades das NBs, e foram estudadas aplicações na remoção de poluentes aquosos e no reúso de água por flotação. A geração de bolhas foi realizada e comparada utilizando duas técnicas: a primeira inclui a pressurização em vaso saturador e despressurização de água saturada com ar em uma válvula agulha (escala de bancada); e a segunda, por uma bomba multifásica (cisalhamento de ar em rotor aberto) e passagem forçada (despressurização) da mistura ar/líquido em uma válvula de agulha (sistema semi-contínuo). Com estas técnicas, tanto microbolhas (MBs, 30-100 μm) como NBs (150-250 nm) foram geradas em concentrações diferentes que dependem da pressão de saturação (Psat) e da tensão superficial do líquido. Para a caracterização das NBs, um procedimento de separação foi conduzido, explorando o fato de que as MBs ascendem e colapsam na superfície do líquido, enquanto que as NBs permanecem em suspensão durante longos períodos. A distribuição de tamanho e a concentração de NBs (número por volume) foram medidas pela técnica NTA (nanoparticle tracking analysis). Foi observado que a concentração de NBs formadas após a despressurização do fluxo de água saturada é função da quantidade de ar dissolvido na água e aumenta com o tempo de saturação até atingir o equilíbrio em 30 min de saturação. A concentração de NBs mostrou-se inversamente proporcional à Psat utilizada, e a maior concentração de NBs (1,5 x 109 NBs.mL-1) foi obtida com Psat de 2,5 bar e uma tensão superficial da solução de 50 mN.m-1, obtida com 100 mg.L-1 de α-Terpineol. Nos estudos em sistema semi-contínuo, a geração de MBs (D32 = 70 μm) e NBs (D32 = 150-300 nm) de ar foi realizada em um skid (sistema protótipo) tendo como principais componentes do sistema de geração de bolhas por cisalhamento do ar e cavitação hidrodinâmica, uma bomba multifásica, uma válvula agulha e uma coluna cilíndrica. Para a caracterização das NBs, o skid foi operado com a recirculação de um volume fixo de 40 L de água deionizada (DI) em uma vazão de líquido de 1000 L.h-1, razão gás/líquido de 7,5% (v/v) e temperatura controlada (21°C ± 1). Contrariamente ao método em nível de bancada de geração de NBs pela despressurização de água saturada (em vaso saturador), na geração contínua com o skid, maiores concentrações de NBs foram obtidas com o aumento da Psat pela ocorrência de mecanismos de cavitação hidrodinâmica adicionais (cisalhamento) aos do primeiro método. No skid, foi observado que as NBs de ar são resistentes ao cisalhamento ocasionado pelos rotores da bomba e às altas pressões de operação (até 5 bar) ao longo dos ciclos de geração de bolhas. O tamanho médio das NBs permanece constante e a sua concentração aumenta em função destes ciclos, atingindo um valor máximo após 29 ciclos, dependente da Psat e da tensão superficial da solução. As maiores concentrações de NBs (4 x 109 NBs.mL-1) foram obtidas com o aumento da pressão (5 bar) e com a diminuição da tensão superficial (50 mN.m-1). Esses fenômenos podem ser explicados pela lei de Henry e pela menor energia requerida para formação de bolhas quando a tensão interfacial ar/líquido for menor e maior for a diferença de pressão da fase líquida com relação à pressão atmosférica. O diâmetro médio e concentração destas NBs não variaram significativamente em um período de 2 meses, o que demonstrou a alta estabilidade destas NBs em concentrações elevadas. Ainda, quando a bomba multifásica foi operada sem injeção de ar, foi observado o mesmo efeito de aumento de concentração de NBs em função do nº de ciclos de geração. Nestas condições, um aumento da velocidade de fluxo do líquido (de 67 para 127 m.h-1) e um aumento da turbulência na saída da válvula agulha potencializou a formação de cavidades e a formação de um maior número de NBs (até 70% maior). Com relação aos parâmetros de dispersão de ar, altos valores de holdup (percentagem em volume de ar no líquido) de ar e fluxo de área superficial de bolhas (Sb), importantes para a flotação, foram obtidos (6,8% e 235 s-1, respectivamente) em uma pressão de operação de 4 bar. Foram realizados estudos de remoção de íons Fe+3, na forma de precipitados coloidais e nanopartículas de Fe(OH)3 (pH 7) por flotação com MBs e NBs e com NBs isoladas; em baixas pressões de saturação (concentração mais alta de NBs); e em altas pressões (onde a concentração de NBs é menor). A utilização de uma alta concentração de NBs juntamente com as MBs geradas na flotação em uma Psat de 2 bar, foi responsável por uma remoção de Fe(OH)3 superior a 99% (residual = 0,9 mg.L-1) e uma redução de turbidez de 95% (residual = 0,6 NTU). A flotação com uma Psat de 4 bar é mais rápida em função deste maior arraste de agregados por MBs (velocidade média de ascensão de bolhas/precipitados = 0,07 cm.s-1). Os resultados se explicam em termos do aprisionamento ou oclusão das NBs nos precipitados coloidais e do grau de aeração (demonstrado em microfotografias). Como resultado, diminui a densidade relativa destes precipitados, inferior à da água. Estudos de remoção, por flotação com MBs e NBs, de dispersões oleosas de petróleo (com 30 g.L-1 de NaCl) foram estudados após a floculação com 5 mg.L-1 de uma poliacrilamida catiônica (Dismulgan) em pH 7. A melhor remoção de óleo (>99% de eficiência) foi obtida com uma pressão de saturação de 5 bar, pela redução do teor de óleo (concentração inicial = 334–484 mg.L-1 mg/L) na água tratada a < 1 mg.L-1. Adicionalmente, a flotação utilizando uma pressão de 3,5 bar permitiu a obtenção de uma água tratada com teores de óleo inferiores a 29 mg.L-1, meta técnica deste estudo por ser o limite de emissão em plataformas de petróleo para descarte de água produzida em alto mar. A flotação foi bastante rápida e seguiu um modelo de primeira ordem, com constante cinética de flotação de 1,3 e 1,8 min-1 para as Psat de 3,5 e 5 bar, respectivamente. A injeção de NBs isoladas em conjunto com MBs residuais (condicionamento) após a etapa de floculação com 1 e 3 mg.L-1 de Dismulgan aumentou a hidrofobicidade dos agregados, facilitando a adesão entre bolhas e flocos oleosos, e aumentando a eficiência geral do processo de flotação de 73 para 84%, e de 92 para 95%, respectivamente. A flotação com NBs isoladas em conjunto com MBs residuais obteve eficiências de remoção de óleo de 75 e 90%, com e sem NaCl (30 g.L-1), respectivamente. Acredita-se que nestes casos, as NBs se aprisionam e aderem como “pancakes” nas gotículas de óleo floculadas, formando flocos oleosos aerados. O estudo aplicado de floculação-flotação com bomba multifásica para geração de bolhas, associado à ozonização (processo FFO), no tratamento de efluentes e reúso de água na lavagem de veículos demonstrou como principais resultados que a água de reúso era clarificada (turbidez = 10 NTU), sem odor (sulfeto < 1 mg.L-1), sem risco microbiológico (E. coli < 1,8 NMP.100.mL-1) e sem formação de espuma (surfactantes = 1,3 mg.L-1). Uma avaliação de custos mostrou que o período de amortização do equipamento FFO em sistemas de reciclagem de água na lavagem de veículos é dependente principalmente da tarifa da água e da demanda diária de lavagens, podendo ser inferior a 1 ano em municípios brasileiros. Os resultados obtidos nesta tese permitiram aprimorar e determinar as condições ótimas de técnicas de geração de elevadas concentrações de NBs, extremamente estáveis e demonstraram o elevado potencial destas bolhas para viabilizar diferentes rotas de tratamento e aplicações no tratamento de efluentes líquidos e reúso de água por flotação. / The main objective of this doctoral thesis was to develop a new method of generating air nanobubbles (NBs) in aqueous solutions by hydrodynamic cavitation. The main parameters involved in the formation and properties of NBs were assessed and applications were studied in the removal of aqueous pollutants models for water reuse by flotation. The generation of bubbles was carried out and compared using two techniques; i. Pressurization in a saturator vessel and depressurization of air-saturated water in a needle valve (bench level); and ii. Using a multiphase pump (air shearing in an open imeller) and depressurization of the ar/liquid mixture in a needle valve (semi-continuous system). By using these techniques, both microbubbles (MBs 30-100 uM) and NBs (150-200 nm) were generated in different concentrations as a function of the saturation pressure (Psat) and surface tension (liquid/air). For the characterization of NBs, a separation procedure was conducted exploiting the fact that the MBs rise and collapse at the liquid surface, while the NBs remain in suspension for long periods. The size distribution and concentration of NBs (number by volume) were measured by the NTA (nanoparticle tracking analysis) technique. It was found that the concentration of NBs formed after depressurizing the saturated water flow is a function of the amount of air dissolved in the water and increases with the saturation time achieving equilibrium after 30 min saturation. The concentration of NBs was inversely proportional to the Psat values, and more NBs (1.5 x 109 NBs.mL-1) were obtained at Psat - 2.5 bar and at a surface tension of 50 mN.m- 1, obtained with 100 mg.L-1 of α-Terpineol. In the semi-continuous system, the generation of MBs (D32 = 70 μm) and NBs (D32 = 150-300 nm) of air was performed with in a system called in this thesis as skid; with a multiphase pump, a needle valve and a cylindrical column as main components. For the characterization of NBs, the skid was operated with recirculation of a fixed volume of 40 L of deionized (DI) water at a liquid flow rate of 1000 L.h-1, at a gas / liquid ratio of 7.5% and controlled temperature (21°C ± 1). Contrary to the method at bench level, the NBs generation by the depressurization of air-saturated water (in saturator vessel), with the skid, higher concentrations of NBs were obtained increasing Psat due to the hydrodynamic cavitation mechanism (air shearing) in comparison with the first method. In the skid, it was observed that air NBs are resistant to shearing caused by pump impellers and to the high operating pressures (up to 5 bar) throughout the bubble generation cycles. The size of the NBs remained constant and its concentration increases as a function of these cycles, reaching a condition of equilibrium after 29 cycles; this was dependent on Psat and the surface tension of the solution. The highest concentrations of NBs (4 x 109 NBs.mL-1) were obtained with increasing pressure (5 bar) and reducing of surface tension of water (50 mN.m-1). These phenomena can be explained by the Henry's Law and the lower energy required for bubbles formation when the interfacial tension (air / liquid) is smaller and the higher is the difference between the Psat and the atmospheric pressure. The mean diameter and concentration of these NBs did not vary significantly over a period of two months, which demonstrated the high stability of these concentrated NBs. Furthermore, when the multiphase pump was operated without injecting air, it was observed the same effect of increasing concentration of NBs along the generation cycles. Thus, a greater fluid flow rate (from 67 to 127 m.h-1) and the increase of turbulence at the outlet of the valve needle potentiated the formation of cavities and the generation of a greater number of NBs (up to 70% higher). With respect to air dispersion parameters, high holdup (percentage by volume of air in the liquid) and superficial area flow density (Sb) values, important parameters for flotation, were obtained (6.8% and 235 s -1, respectively) at a 4 bar operating pressure. Studies on the removal of Fe+3 ions, as colloidal precipitates and Fe(OH)3 (pH 7) nanoparticles were carried out by flotation with MBs and NBs and with isolated NBs; at low saturation pressures (higher concentration of NBs); and at high pressures (where the concentration of NBs is lower). The use of a high concentration of NBs, together with MBs in a Psat of 2 bar generated along with the flotation, was responsible for a Fe(OH)3 removal of > 99% (residual = 0.9 mg.L-1), a turbidity reduction of 95% (residual = 0.6 NTU). The flotation with a Psat of 4 bar is faster due to this increased entrainment of aggregates by MBs (average rising velocity of the bubbles/precipitates = 0.07 cm.s-1). The flotation with isolated NBs (or “floatation” by NBs entrapment and reduction of the relative density of aggregates), was responsible for the removal of up to 91% of the total iron content, which resulted in a final concentration of 2.7 mg.L-1 (feed iron content =30 mg.L-1). The results are explained in terms of the entrapment or occlusion of NBs in the colloidal precipitates and higher aeration degree (shown in the photomicrographs). As a result, it decreases the relative density of these precipitates, lower than the water´s. The removal of oil dispersions (30 g.L-1 NaCl), by flotation with NBs and MBs, was carried out after flocculation with 5 mg.L-1 of a cationic polyacrylamide (Dismulgan) at pH 7. The best oil removal (> 99% efficiency) was obtained at 5 bar by reducing the oil content (feed concentration = 334-484 mg.L-1) in the treated water to < 1 mg.L-1. Furthermore, it was obtained a treated water with an oil content lower than 29 mg.L-1, which was a technical goal of this study (emission limit) for produced water discharge at offshore oil platforms, by using a Psat of 3.5 bar. The flotation was very fast and followed a first order model with a flotation rate constant of 1.3 and 1.8 min-1 for Psat values of 3.5 and 5 bar, respectively. The injection of isolated NBs in conjunction with residual MBs (conditioning stage) after flocculation with 1 and 3 mg L-1 Dismulgan increased the hydrophobicity of the aggregates, thus facilitating the adhesion between bubbles and oily flocs and increasing the overall efficiency of the flotation process from 73 to 84% and from 92 to 95%, respectively. The flotation with isolated NBs in conjunction with residual MBs resulted in oil removal efficiencies of 75 and 90% with and without NaCl (30 g.L-1), respectively. It is believed that in these cases the NBs entrap and adhere as "pancakes" into the flocculated oil droplets, forming aerated oily flocs. The applied study of flocculation-flotation with multiphase pump, associated with ozonation (FFO process) for wastewater treatment and water reuse in vehicle washing, demonstrated as main results the clarification of the reclaimed water (turbidity = 10 NTU), which was odorless (sulfide <1 mg.L-1) without any microbiological risk (E. coli <1.8 NMP.100.mL-1) and with no foaming (surfactant = 1.3 mg.L-1). A cost assessment showed that FFO equipment amortization period in vehicle washing water recycling systems is dependent mainly on water prices and on the daily washes demand, and it may be less than 1 year in Brazilian municipalities. The results obtained in this thesis allowed to improve and determine the optimal process conditions for the generation of high concentrations of extremely stable NBs, and demonstrated the high potential of these bubbles to enable different routes of treatment and applications in wastewater treatment and water reuse by flotation.
246

Uso de filtro de mangas para tratamento de gases resultantes da combustão de bagaço de cana /

Barbosa, Marcelo Garcia. January 2014 (has links)
Orientador: Celso Luiz da Silva / Banca: Geraldo Luiz Palma / Banca: José Roberto Simões Moreira / Resumo: Com o advento de normas e restrições cada vez mais rígidas por parte dos órgãos ambientais, em virtude da crescente preocupação com as modificações climáticas recentes geradas pela contínua descarga de emissões poluentes na atmosfera, torna-se essencial a implantação de equipamentos que amortizem ou eliminem esses resíduos. Por se tratar fundamentalmente de uma questão de saúde pública, atualmente a implantação de qualquer planta industrial que possa gerar impacto ambiental, ou até mesmo adequação de equipamentos já instalados para a não geração de poluentes ou geração dentro de limites adequados, passa cada vez mais por fiscalização rigorosa dos órgãos ambientais. Para este estudo, foi implantado um sistema de tratamento de gases pós-caldeira de queima de resíduos sólidos (bagaço de cana). Os gases oriundos do processo são transportados através de duto passando pelo precipitador do tipo ciclone e coletor do tipo filtro de mangas. O comportamento dos gases e filtro de mangas foi monitorando constantemente para coleta de dados através de termopares e transmissor de pressão, sendo ao final do período de operação feita a análise da composição dos gases antes e após filtro de mangas, além da análise do elemento filtrante. Os resultados das análises de NOx e material particulado, demonstrando eficiência de filtração acima de 99% como esperado juntamente com os dados de temperatura e pressão em níveis pertinentes a um sistema de tratamento de gases com coletor tipo filtro de mangas, corroboram o que se queria demonstrar come este estudo, que é a possibilidade do uso de filtros de tecido para tratamento de gases oriundos da combustão de resíduos sólidos / Abstract: With the advent of standards and increaingly stringent restrictions by environmental agencies due to the increasing concern about the recent climate changes generated by the continuous discharge of pollutants emitted into the atmosphere, it becomes essential that the deployment of equipment or disposal of such reduce residues. Because it is fundamentally a public health issue, currently the implementation of any industrial plant that can generate environmental impact, or even fitness equipment already intalled for the non-generation of pullutants or generation within appropriate limits, is increasingly on strict enforcement of the environmental agency. For this study, we implemented a system of post-treatment gas from a boiler burning solid waste. The gases from the process are transported by pipeline passing through the cyclone and the bag filter were constantly monitored to collect data using thermosensors and pressure transmitters, and at the end of the operation in was made the anlysis of the gas coposition before and after the bag filter, besides the analysis filter element. The results of te analysis of NOx and particulate matter, demonstrating high filtration efficiency above 99% as expected along with the data of temperature and pressure at levels relevant to a gas treatment system eith a bag filter collector type, corroborate what was expected from this study demonstrate that it is possible to use fabric filters for treating gases from the combustion of solid waste / Mestre
247

Detecção de bactérias do gênero Legionella em amostras de água provenientes de sistemas de ar condicionado / Detection of bacteria genus Legionella in water samples of airconditioning systems [master degree]

Helder Yudji Etto 16 June 2009 (has links)
Introdução: Destaca-se a importância dos organismos do gênero Legionella como agentes causadores de doenças do aparelho respiratório como a legionelose ou doença do Legionário, e ainda de um controle na manutenção adequada de sistemas de ar condicionado, uma vez que estes foram identificados como ambientes favoráveis à proliferação desses microrganismos. Objetivo: Devido à importância de bactérias do gênero Legionella como agentes causadores de doenças, e um crescente número de casos de legionelose relacionados à permanência em ambientes fechados, este estudo teve como objetivo determinar a presença de Legionella em águas de bandejas de sistemas de ar condicionado. Métodos: Foram realizadas análises de amostras de água provenientes de bandejas de ar condicionado de dois hospitais, uma instituição de ensino superior e um centro comercial, totalizando 41 amostras. Volumes de 1L das amostras coletadas foram concentrados em membrana, seguida de tratamento ácido. Alíquotas das amostras tratadas e não tratadas com ácido, foram então inoculadas em meio Agar BCYE-, com e sem adição de antibióticos. As cepas isoladas foram submetidas a teste sorológico para identificação. Resultados: Das amostras analisadas, 4 (9,5%) apresentaram resultado positivo para Legionella sp.; uma no centro comercial e três em um dos hospitais estudados. Os isolados foram submetidos a teste sorológico, sendo um identificado como Legionella pneumophila sorogrupo 1 e três como seis prováveis espécies:L. longbeachae, L. bozemanni, L. dumoffi, L. gormanii, L. jordanis, L. micdadei, L. anisa . Conclusão: Os resultados deste estudo comprovam a presença de Legionella sp. nos sistemas de ar condicionado pesquisados, sendo observada maior freqüência dos isolados em amostras analisadas oriundas dos hospitais.Os resultados demonstraram a importância e a necessidade de planos de monitoramento em sistemas de 7 ar condicionado como medida preventiva à colonização por organismos patogênicos nesses sistemas e dessa forma proteger a saúde dos ocupantes e usuários de ambientes climatizados artificialmente. / Introduction: It highlights the importance of organisms genus Legionella as responsible for diseases of the respiratory system such as legionellosis or Legionnaires´disease, and a control on proper maintenance of air conditioning systems, as these were identified as favorable environment for the proliferation of these microorganisms. Objective: Due to the importance of Legionella as causative agents of disease and a growing number of cases of legionellosis related to stay indoors, this study aimed to determine the presence of Legionella in water samples from air-conditioning systems. Methods: We performed analysis of samples of water from trays of airconditioning systems in two hospitals, a university and a trade center, totalizing 41 samples. One liter volumes of water samples were concentrated on membrane, followed by acid treatment. Aliquots of the sample treated and not treated with acid, were inoculated on BCYE- agar medium, with and without added antibiotics. The strains were subjected to serological identification. Results: Out of the samples analyzed, 4 (9.5%) were positive for Legionella sp.; one in a trade center and three in one of the hospitals. Isolates were submitted to serological testing, one identified as Legionella pneumophila serogroup 1 and three as probable six species: L. longbeachae, L. bozemanni, L. dumoffi, L. gormanii, L. jordan, L. micdadei, L. anise. Conclusion: The results confirm the presence of Legionella sp. in air conditioning systems studied. It was observed a higher frequency in isolates from hospitals. The results demonstrated the importance and necessity of monitoring plans in air-conditioning systems as a preventive measure to colonization by pathogens in these systems and protect the health of occupants and users of these buildings.
248

Efeitos da poluição do ar sobre a função pulmonar: um estudo de coorte em crianças de Cubatão / Effects of air pollution on lung function: a cohort study in Cubatão children

Vera Anna Hofmeister 11 September 1991 (has links)
É feita a análise da evolução de provas funcionais ventilatórias de dois grupos de crianças clinicamente sadias, residentes no Município de Cubatão, examinadas inicialmente em dois estudos transversais realizados respectivamente em 1983 (verão) e em 1985 (inverno). O princípio epidemiológico que norteou essa pesquisa foi a realização de um estudo de Coorte Não-Controlada, ou mais apropriadamente, um Estudo Ecológico Longitudinal, onde esses dois grupos de crianças foram anualmente submetidos a exames espirométricos no período de 1987 a 1989, mantida a estrita sazonalidade, ou seja, o Grupo de 1983 foi sempre reexaminado no verão, enquanto que o Grupo de 1985 sempre no inverno. Aproximadamente 1.110 crianças, oriundas de todas as áreas do Município foram submetidas a provas de função pulmonar utilizando-se espirômetro seco, com especial ênfase na análise do comportamento da Capacidade Vital Forçada (CVF), do Volume Expiratório Forçado no Primeiro Segundo (VEF1,0), do \"Peak-Flow\" ou Pico de Fluxo Expiratório (PFE), e do Fluxo Médio Expiratório Forçado (FMF25-75 por cento ), todos considerados como indicadores sensíveis às influências dos níveis de poluição atmosférica registrados em Cubatão. As informações concernentes à poluição do ar foram obtidas através dos relatórios de pesquisas efetuadas pela Companhia de Tecnologia de Saneamento Ambiental do Estado de São Paulo (CETESB) e envolveram a análise das estimativas de emissões das indústrias prioritárias de Cubatão, das concentrações horárias de material particulado (MP), dióxido de enxofre (SO2) e do ozona (O3) registradss nas estações amostradoras de Vila Parisi, Cubatão-Centro e Vila Nova no período de Novembro de 1983 a Dezembro de 1989. Também integrou o contexto de análise, a avaliação das principais metas do Programa de Controle de Poluição do Ar instituído pela CETESB na região a partir de 1984, com o objetivo de se verificar se as reduções pretendidas nos níveis de poluição do ar se fizeram acompanhar de melhorias nas provas funcionais pulmonares das crianças estudadas. Verificou-se que os episódios agudos de poluição do ar, principalmente devidos ao material particulado, mostraram algum decréscimo. No entanto, aqueles devidos a oxidantes fotoquímicos, representados pelos níveis de ozona, tiveram progressivo incremento no período de 1984 a 1988, tanto em relação ao número de episódios, como na persistência e gravidade dos mesmos. Os resultados espirométricos indicaram que em ambos os grupos de crianças a função pulmonar mostrou decrementos significativos, com perdas em tomo de 5 a 8 por cento ao ano, em média, quando comparados com os valores inicialmente registrados por ocasião dos estudos transversais. Apesar das reduções terem sido observadas em todas as variáveis espirométricas, os maiores decrementos verificaram-se principalmente nas medidas de fluxo (PFE e FMF25_75 por cento ), e coincidiram com o ano em que foram assinalados os mais graves episódios de poluição devida a oxidantes fotoquímicos. Os bairros Cota 95, Cota 200, Jardim das Indústrias e Vila Natal, localizados na área de influência do núcleo industrial químicofpetroquímico sobressairam-se como os mais críticos em função dos piores resultados espirométricos apresentados ao longo de todo o estudo. Pôde-se concluir que apesar da função pulmonar das crianças ainda não ter atingido níveis considerados como patológicos, mesmo registrando valores inferiores aos limites da normalidade nas variáveis de fluxo no ano de 1988, verificou-se que de ano para ano a função pulmonar vem decrescendo progressivamente indicando que esta vai sendo afetada pela exposição as poluentes da região e que as medidas de controle da poluição instituídas em Cubatão não tiveram a eficácia esperada. Continuando nessa mesma trajetória evolutiva, isso poderá acarretar sérios e irreparáveis prejuízos à saúde da população. É necessário, portanto, a adoção de urgentes medidas para a melhoria da qualidade do ar em Cubatão nos anos futuros, no intuito de prevenir sérios agravos à Saúde Pública. / The purpose of this study was to investigate the effects of exposure to air pollution on lung function of children. Two groups of clinically healthy children, living at different areas of the city of Cubatão, who had been submitted to lung function tests in a previous cross-sectional study (1983 summertime and 1985 wintertime) were annually reexamined using the same type of test during the period 1987 to 1989. On epidemiological basis this is a longitudinal study, where every individual of the two groups of children was measured at each ocasion, always in the same season of the previous examination. About 1,110 children from all areas of the city were examined once a year using dry spirometer, with special emphasis on FVC, FEV 1,0, PEF and FMF25-75 per cent measurements, since they were considered as those which could be most affected by the local air pollution. Information regarding the conditions of air pollution were obtained from the CETESB\'s written reports. They include the estimate emissions of the main industries of the region; the hourly concentrations of particulate matter, sulfur dioxide and ozone measured in the sampling stations located in Vila Parisi, Cubatão-Centro and Vila Nova during the October/1983 to December/1989 period and also the results of the Source Control Strategy introduced by CETESB since 1984. It was observed that the acute episodes of air pollution due to PM were reduced in number. However, those due to photochemicaf oxidants, mainly represented by ozone leveis, were progressively more frequent during the period from 1984 to 1988; both their number and their severity increased during this period. Spirometric results shows that in both groups of children the lung function was significantly impaired, with losses of 5 to 8 per cent per year, when compared with the initial values of the cross-sectional studies. Despite the fact that all lung function parameters decline, the flow (PFE and FMF2s-7s per cent ) values were those most affected and closely related to the most serious episodes of air pollution due to photochemical oxidants mainly those observed in 1988. Children living in the areas of Cota 95, Cota 200, Jardim das Indústrias and Vila Natal, situated in the nearest area of influence of the chemical and petrochemical industries, presented worst spirometric results than children living in other places of Cubatão. The lung function of the examined children did not attain pathological values, despite the fact of presenting the worst results in flow parameters during the year of 1988. It was observed that their lung function is progressively impaired year by year, a clear indication of the progressive effects of air pollution on their lung function, and if such impairment continues there will carne the time when lung function will probably reach a pathologicallevel. It is concluded that there is an urgent need of improving the quality of air of Cubatão to avoid serious Public Health problems in a quite near future.
249

Flotação por Ar Dissolvido (FAD) de micropartículas, caracterização de microbolhas e medidas de força de interação bolha-partícula

Englert, Alexandre Hahn January 2008 (has links)
O presente trabalho descreve um estudo teórico-experimental da flotação por ar dissolvido (FAD) de micropartículas (diâmetro dp < 100 μm), incluindo caracterização de microbolhas (db < 100 μm) pela técnica LTM-BSizer de determinação da distribuição de tamanho de bolhas (DTB) e medidas diretas da força de interação bolha-partícula via microscopia de força atômica (AFM). Visando aperfeiçoar a técnica LTM-BSizer, foi desenvolvido um novo procedimento (NP) automático de processamento/análise de imagens de bolhas. O NP consistiu em um algoritmo contendo as etapas de conversão das imagens coloridas para tons de cinza, limiarização, preenchimento dos “buracos” das bolhas e análise. Imagens de microbolhas geradas por uma bomba centrífuga multiestágio foram utilizadas para comparar os resultados obtidos pelo NP com os obtidos pelo antigo procedimento (AP) da técnica. Diferenças menores que 20 % foram observadas nos resultados obtidos pelos dois procedimentos para o diâmetro médio aritmético, desvio-padrão e diâmetro médio de Sauter das bolhas. O processamento/análise com o NP foi realizado em um tempo inferior (> 30 %) ao requerido pelo AP, mostrando ainda a vantagem de detectar confiavelmente bolhas circulares não-agrupadas nas imagens. Estudos experimentais de FAD de micropartículas de quartzo (diâmetro médio volumétrico de 13,2 ± 0,3 μm) foram realizados utilizando dois sistemas distintos de flotação. As amostras de quartzo foram tratadas com uma amina comercial (agente coletor) e as bolhas foram caracterizadas pela técnica LTM-BSizer. A DTB obtida para as bolhas geradas em uma pressão de saturação de 294 kPa mostrou que 94 % (em número) das mesmas possui db menor que 100 μm, apresentando diâmetros médios de Sauter e aritmético de 79 ± 5 m e 56 ± 3 μm, respectivamente. Valores de recuperação mássica total de quartzo entre 6,4 ± 5,8 % e 53,3 ± 5,9 % foram obtidos na FAD em distintas concentrações de coletor (até 2 mg g-1), sendo a concentração ótima do mesmo determinada em 1 mg g-1. A recuperação de quartzo por flotação real em função de dp mostrou um mínimo local situado em aproximadamente 3-5 μm, contribuindo para a discussão na literatura sobre a existência do mesmo, interpretado como uma mudança no mecanismo de captura bolha-partícula (convecção-difusão). Estudos de FAD com partículas esféricas de sílica (dp = 1 μm) foram ainda realizados utilizando uma célula de flotação contendo uma válvula de três vias, necessária para obtenção de uma coluna d’água acima da suspensão das partículas, minimizando o arraste das mesmas. As partículas foram amplamente caracterizadas (distribuição de tamanho, potencial zeta, rugosidade superficial, umidade e superfície específica), sendo uma fração hidrofobizada com trimetilclorosilano (TMCS) em ciclohexano. As técnicas de flotação em filme e ascensão capilar demonstraram uma maior hidrofobicidade das partículas metiladas com relação às partículas de sílica não-tratadas com TMCS (amostra original). Os resultados de FAD mostraram não haver diferença significativa entre as recuperações mássicas obtidas para as partículas de sílica original e metilada, sendo observado um aumento linear na recuperação (0,1 ± 0,5 % a 27,0 ± 1,2 %) com um aumento do volume de água saturada utilizado (10 a 40 cm3, respectivamente). Ainda, resultados obtidos utilizando um volume de água saturada de 10 cm3 mostraram que a pressão de saturação possui efeito significativo na FAD das partículas esféricas de 1 m (dp). Valores de recuperação medidos experimentalmente mostraram-se relativamente próximos aos correspondentes valores previstos por um modelo teórico da captura bolha-partícula (flotação real). Com a finalidade de investigar diretamente a interação bolha-partícula na flotação, medidas de força-versus-distância entre uma bolha de ar e uma partícula esférica (hidrofílica ou hidrofóbica) em água foram realizadas pela técnica da sonda coloidal. Um microscópio de força atômica comercial foi empregado utilizando-se uma célula de fluido padrão sem anel O-Ring, permitindo contato da água com o ar. Esferas de sílica (dp entre 5 μm e 27 μm), fixas na extremidade de cantilevers em forma de V, foram utilizadas como sondas coloidais hidrofílicas (limpeza a plasma) e hidrofóbicas (exposição a TMCS). Os resultados mostraram claramente que, sob condições extremas de limpeza, somente uma força monotonicamente repulsiva entre a bolha e a partícula hidrofílica (durante a aproximação e afastamento) foi observada. Os dados obtidos com uma sonda hidrofílica de sílica de 5,6 ± 0,2 μm (dp) mostraram-se em boa conformidade com modelos teóricos (aproximação da superposição não-linear e Hogg-Healy-Fuerstenau) para a interação bolha-partícula hidrofílica, colaborando para elucidar dados experimentais controversos na literatura referentes à correspondente força de interação. As curvas de força obtidas entre uma bolha e uma partícula hidrofóbica apresentaram tipicamente um pulo-para-contato durante a aproximação bolha/partícula e uma força de rompimento no afastamento das mesmas, confirmando a existência de uma força atrativa na interação. Valores de 107 ± 18 nm e -1,5 ± 0,2 μN foram obtidos (com uma sonda de 27 ± 1 μm) para a distância de pulo-para-contato e força de rompimento, respectivamente. A alta reprodutibilidade da técnica da sonda coloidal na medida das curvas de força bolha-partícula (hidrofílica e hidrofóbica) foi demonstrada. / The present work describes a theoretical/experimental study on the dissolved air flotation (DAF) of microparticles (diameter dp < 100 μm), including characterisation of microbubbles (db < 100 μm) by the LTM-BSizer technique of bubble size distribution (BSD) determination and direct measurements of bubble-particle interaction force via atomic force microscopy (AFM). In order to improve the LTM-BSizer technique, an automatic new procedure (NP) of processing/analysis of bubble images was developed. The NP consisted of an algorithm having the steps of image conversion from color to grayscale, thresholding, filling of bubble “holes” and analysis. Images of microbubbles produced by a multistage centrifugal pump were utilised to compare the results obtained via the NP with the corresponding data obtained by the original procedure (OP) of the technique. Differences smaller than 20 % were observed in the values obtained by both procedures for the arithmetic mean diameter, standard deviation and Sauter mean diameter of the bubbles. Processing/analysis with the NP was conducted in a lower time (> 30 %) than the one required by the OP, showing also the advantage of reliably detecting bubbles as single circles (not as clusters) on the images. Experimental studies for the DAF of quartz microparticles (volume-moment diameter of 13.2 ± 0.3 μm), using two different flotation setups, were conducted. Quartz samples were treated with a commercial amine (collector agent) and bubbles were characterised by the LTM-BSizer technique. BSD obtained for the bubbles generated at a saturation pressure of 294 kPa showed 94 % (by number) of the bubbles having db lower than 100 μm, with a Sauter and arithmetic mean diameters of 79 ± 5 μm and 56 ± 3 μm, respectively. Values of total quartz recovery ranging from 6.4 ± 5.8 % to 53.3 ± 5.9 % (by mass) were obtained for the DAF experiments under different collector concentrations (up to 2 mg g-1), with an optimal concentration found at 1 mg g-1. Quartz recovery by true flotation as a function of dp exhibited a local minimum at approximately 3-5 μm, contributing to the discussion in the literature about the existence of such minimum, interpreted as a change in particle-bubble collection mechanism (convection-diffusion). DAF studies using spherical silica particles (dp = 1 μm) were conducted with a flotation cell containing a three-way tap, aiming the formation of a water column above the particle suspension and thus minimizing particle entrainment. Particles were fully characterised (size distribution, zeta potential, surface roughness, water content and specific surface area), being a fraction hidrophobized by trimethylchlorosilane (TMCS) in cyclohexane. The film flotation and capillary rise techniques demonstrated that the methylated particles were more hydrophobic than the untreated silica particles (original sample). DAF experiments showed no significant difference between mass recovery values obtained for the original and methylated silica particles, being observed a linear increase in recovery (0.1 ± 0.5 % to 27.0 ± 1.2 %) with an increase in saturated water volume (10 to 40 cm3,respectively). Furthermore, results obtained using a saturated water volume of 10 cm3 have shown that the saturation pressure had a significant effect on the DAF of 1 μm (dp) spherical particles. Experimental recovery values were in fairly good agreement with corresponding values predicted by a theoretical model of particle-bubble capture (true flotation). Aiming to directly investigate the bubble-particle interaction in flotation, force-distance measurements between an air bubble and a spherical particle (hydrophilic or hydrophobic) in water were conducted using the colloid probe technique. A commercial atomic force microscope was employed using a standard fluid cell without O-Ring, allowing contact of water with the air. Silica spheres (dp between 5 m and 27 μm) attached to the end of V-shaped cantilevers were utilised as hydrophilic (plasma cleaning) and hydrophobic (TMCS exposure) colloid probes. Results showed clearly that, under very clean conditions, only a monotonic repulsive force (upon approach and retraction) between the bubble and the hydrophilic particle was observed. Experimental data obtained using a 5.6 ± 0.2 μm (dp) hydrophilic silica probe are in good agreement with theoretical models (non-linear superposition approximation and Hogg-Healy-Fuerstenau) for the hydrophilic particle-bubble interaction, contributing to elucidate controversial experimental data reported in the literature on such interaction force. Force-curves obtained between a bubble and a hydrophobic particle typically showed a jump-into-contact upon bubble-particle approach and a detachment force on separation, corroborating the existence of an attractive force in the interaction. Values of 107 ± 18 nm and -1.5 ± 0.2 μN were obtained (using a 27 ± 1 μm probe) for the jump-into-contact distance and detachment force, respectively. The high reproducibility of the colloid probe technique for measuring bubble-particle (hydrophilic and hydrophobic) force curves was demonstrated.
250

Infecção viral respiratória e os efeitos do clima e poluição atmosférica em pacientes sintomáticos respiratórios atendidos em sala de emergência

Silva, Denise Rossato January 2011 (has links)
Base teórica: Infecções virais respiratórias são as causas mais comuns de infecções respiratórias, levando a níveis significativos de morbidade e mortalidade. A prevalência de vírus respiratórios em adultos é amplamente subestimada, já que os dados relevantes dizem respeito a crianças. Variações meteorológicas e poluição do ar provavelmente desempenham um papel nessas infecções. Objetivos: Determinar a proporção de visitas à emergência por síndrome gripal (SG) e síndrome respiratória aguda grave (SRAG) e avaliar a associação entre a frequência de SG/SRAG, a prevalência de vírus respiratórios e fatores meteorológicos/poluição do ar, especialmente na população adulta. Métodos: 11.953 hospitalizações (adultos e crianças) por sintomas respiratórios foram correlacionadas com parâmetros meteorológicos e a concentração de poluentes do ar. Em um subgrupo de pacientes adultos (n=410) com sintomas respiratórios iniciados há menos de 5 dias, aspirados de nasofaringe foram coletados e analisados através do teste de imunofluorescência indireta (IFI). Os dados foram analisados usando análise de séries temporais Resultados: SG e SRAG foram diagnosticas em 3.698 (30,9%) e 2.063 (17,7%) pacientes, respectivamente. Trinta e sete (9,0%) amostras foram positivas pela IFI. Tosse, sibilância, uso de ar condicionado em casa ou no trabalho e casos de SG/SRAG foram mais frequentes em pacientes com IFI positiva do que nos pacientes com IFI negativa. Em um modelo de regressão logística multivariada, a positividade da IFI foi estatisticamente associada com umidade absoluta, uso de ar condicionado em casa ou no trabalho e a presença de mofo em casa. Nos modelos de séries temporais multivariadas, a insolação foi a única covariável independente que foi significativamente associada com a frequência de casos de SG. No modelo para os casos de SRAG, as seguintes variáveis demonstraram ser significativas: temperatura média (β = 0,399; p = 0,025), insolação (β = - 0,392; p = 0,007), umidade relativa (β = - 0,098; p = 0,05) e a concentração média de poluentes (β = - 0,079; p 9 = 0,018). Conclusões: Encontramos que em adultos admitidos na sala de emergência com queixas respiratórias, pelo menos 9% das infecções foram causadas por vírus respiratórios. As correlações encontradas entre variáveis meteorológicas, poluição do ar, casos de SG/SRAG e vírus respiratórios demonstraram a relevância dos fatores climáticos como contribuintes subjacentes significativos para a prevalência de infecções virais respiratórias em uma região temperada. / Background: Respiratory viral infections are the most common causes of respiratory infections, leading to significant levels of morbidity and mortality. The prevalence of respiratory viruses in adults is largely underestimated, as relevant data mostly concern infants and children Meteorological variations and air pollution are likely to play a key role in these infections. Objectives: To determine the proportion of emergency room visits for influenza-like illness (ILI) and severe acute respiratory infection (SARI) and to evaluate the association between ILI/SARI frequency, respiratory virus prevalence and meteorological factors/air pollution, especially in adult population. Methods: 11,953 hospitalizations (adults and children) for respiratory symptoms were correlated with meteorological parameters and concentration of air pollutants. In a subset of adult patients (n=410) with respiratory symptoms within 5 days of onset, nasopharyngeal aspirates were collected and analyzed through indirect immunofluorescence (IFI) test. The data were analyzed using time-series analysi Results: ILI and SARI were diagnosed in 3,698 (30.9%) and 2,063 (17.7%) patients, respectively. Thirty seven (9.0%) samples were positive by IFI. Cough, wheezing, use of air conditioning at home or at work, and ILI/SARI cases were more frequent in patients with IFI positive than in patients with IFI negative. In a multivariate logistic regression model, IFI positivity was statistically associated with absolute humidity, use of air conditioning at home or at work, and presence of mold in home. In the multivariate time-series models, sunshine duration was the only independent covariate that was significantly associated with the frequency of ILI cases. In the model for SARI cases, the following variables proved to be significant: mean temperature (β = 0.399; p = 0.025), sunshine duration (β = - 0.392; p = 0.007), relative humidity (β = - 0.098; p = 0.05), and mean concentration of pollutants (β = - 0.079; p = 0.018). Conclusions: we found that in adult patients admitted to emergency room with respiratory complaints, at least 9% of infections were caused by respiratory viruses. The 11 correlations found among meteorological variables, air pollution, ILI/SARI cases, and respiratory viruses demonstrated the relevance of climate factors as significant underlying contributors to the prevalence of respiratory virus infections in a temperate region.

Page generated in 0.0556 seconds