• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 125
  • 8
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 135
  • 73
  • 63
  • 45
  • 40
  • 27
  • 23
  • 20
  • 17
  • 16
  • 15
  • 14
  • 14
  • 13
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Vibroacustografia na avaliação tridimensional de artroplastia total de quadril / Vibro-acoustography in the tridimensional evaluation of total hip arthroplasty

Kamimura, Hermes Arytto Salles 29 April 2011 (has links)
A vibroacustografia (VA) é uma técnica de imagem de alta resolução lateral (<0,7 mm), livre de speckles, não invasiva e que utiliza radiação não-ionizante, baseada no fenômeno de combinação não-linear de ondas de ultrassom (MHz) que gera uma região focal estreita de baixa frequência (kHz). Neste trabalho, propõe-se uma avaliação tridimensional baseada em imagens de VA da área descoberta de implantes, após o procedimento cirúrgico de artroplastia total de quadril (ATQ). A ATQ é uma técnica terapêutica de substituição de articulações do quadril por implantes, em pacientes com osteoartrose avançada. Atualmente, o acompanhamento pós-operatório é auxiliado pela análise de radiografia plana por raios-X. Contudo, esta técnica apresenta limitações na avaliação da estabilidade dos implantes, tais como: avaliação imprecisa da área, uma vez que, a radiografia plana trata o problema tridimensional como bidimensional; impossibilidade de visualização de algumas regiões do implante, devido ao sobreposicionamento das regiões numa imagem planar; restrição do uso de radiação ionizante na região da pelve em pacientes jovens. Devido à alta atenuação da onda de ultrassom incidindo sobre objetos densos, a VA pode ser ajustada para adquirir imagens relativas, principalmente, à superfície destes. Uma correção da topologia baseada na geometria do implante é apresentada, a fim de se avaliar com precisão a área superficial na representação tridimensional da imagem de VA. A correção da topologia baseada em aquisições em modo-B também é apresentada, sendo útil na avaliação da forma de ossos ou nos casos em que a forma do objeto estudado é desconhecida. Além disso, é apresentado um estudo numérico da utilização de transdutores matriciais reconfiguráveis (RCA, do inglês reconfigurable array) para a formação de feixe em VA. Um estudo paramétrico da seleção de abertura, número de canais, número de elementos, distância focal e parâmetros de varredura eletrônica do feixe é apresentado para demonstrar a viabilidade e avaliar o desempenho da imagem de VA utilizando o RCA. A função de espalhamento de ponto do sistema foi calculada com base em métodos de espectro angular usando a aproximação de Fresnel para fontes retangulares. Foram discutidas as vantagens de transdutores bidimensionais e RCA, e aspectos relacionados à importância clínica da implementação do RCA na VA, tais como resolução espacial, taxa de aquisição da imagem e implementação do RCA em máquinas comerciais. Conclui-se que: a aquisição de imagens por VA foi menos sensível ao ângulo de incidência das ondas de ultrassom do que por modo-B e apresentou alta resolução e alto contraste entre o osso e o implante, o que permitiu uma avaliação precisa da área exposta do implante; os transdutores RCA podem aprimorar a aquisição de imagens por VA, devido à sua resolução espacial similar à de transdutores confocais e à possibilidade de deflexão eletrônica do feixe (em inglês steering) nos planos de elevação e azimutal. / Vibro-acoustography (VA) is a high lateral resolution (<0.7 mm), speckle-free, non- ionizing and non-invasive image based on the nonlinear combination phenomenon of ultrasound waves (MHz) that generates a narrow focus region of low frequency (kHz). In this work, we propose a VA-based tridimensional evaluation of the exposed area of implants, after total hip arthroplasty (THA). THA is a therapeutic surgery procedure in which the hip joints are replaced by metal prostheses in patients with advanced osteoarthritis. Currently, the postoperative assessment of THA is performed by analyzing planar X-ray radiographies. However, this technique presents limitations in the implant stability evaluation such as: inaccurate evaluation of the area, since the planar radiography reduces the tridimensional problem into a two-dimensional one; problems in the visualization of some regions of the implants due to the superimposition of the regions; limitations of using ionizing radiation in the pelvis region of young patients. Due to the high attenuation of the ultrasound wave into objects of high density, the VA image can be set to mainly acquire the surface information. Topological correction based on the geometry of the implant is presented in order to accurately evaluate the surface area in tridimensional representation of the VA image. The topological correction based on B-mode slices is also presented and is useful in the evaluation of bone shape or in cases which the shape of the object is unknown. Furthermore, it is presented a numerical study of the use of reconfigurable arrays (RCA) for VA beam formation. A parametric study of the aperture selection, number of channels, number of elements, focal distance and steering parameters is presented in order to show the feasibility and evaluate the performance of VA imaging based on RCA. The point-spread function of the system is calculated based on angular spectrum methods using the Fresnel approximation for rectangular sources. Advantages of two-dimensional and RCA arrays and aspects related to clinical importance of the RCA implementation in VA such as spatial resolution, image frame-rate, and commercial machine implementation are discussed. It is concluded that: the VA image is less sensitive to the wave incident angle than B-mode; the VA image presents high-resolution and high-contrast between bone and implant, which allowed an accurate evaluation of the uncovered area; RCA transducers improve the VA acquisition by producing spatial resolution similar to confocal transducers, and due to the possibility of steering in elevation and azimuthal planes.
102

Estudo comparativo entre dois métodos de reabilitação fisioterapêutica na artroplastia total do joelho: protocolo padrão do IOT x protocolo avançado / Comparative study between two physiotherapeutic rehabilitation methods in total knee arthroplasty: IOT standard protocol and advanced protocol

Silva, Adriana Lucia Pastore e 13 December 2006 (has links)
Este estudo compara dois protocolos de reabilitação fisioterapêutica - um com três meses de duração (protocolo padrão IOT) e outro com dois meses (protocolo avançado) - para evidenciar a real necessidade de um tempo prolongado de reabilitação em 31 pacientes submetidas a artroplastia total do joelho. O estudo é prospectivo e randomizado e a faixa etária avaliada está entre 60 e 76 anos. As pacientes são avaliadas no pré-operatório e após o tratamento com avaliação clínica (escala de dor, Knee Society Score, SF-36 e goniometria) e avaliação de força (avaliação isocinética) para comparação dos protocolos. A análise estatística dos valores da escala de dor, do Knee Society Score, da amplitude de movimento, do pico de torque muscular e da avaliação da qualidade de vida (SF-36) demonstra que todas as pacientes obtêm melhora quando comparamos o pré e pós-operatório, independente do grupo. Conclui-se que o protocolo de reabilitação fisioterapêutica com dois meses de duração para o pós-operatório de artroplastia total do joelho mostra ser eficaz, alcançando os mesmos objetivos e resultados que o protocolo com três meses de duração / The present study compares two physiotherapeutic rehabilitation protocols - one lasting three months (standard IOT protocol), the other lasting two months (advanced protocol) - to assert the actual need of a prolonged rehabilitation period in 31 cases of patients who went through total knee arthroplasty. The study is prospective and randomized; the age group of evaluated patients is between 60 and 76 years-old. In order to compare the two protocols, patients are evaluated before surgery and after treatment, by means of clinical evaluation (pain scale, Knee Society Score, SF-36 and goniometry) and isokinetic strength test. Statistical analyses of results from pain scale, Knee Society Score, movement amplitude, muscular torque peak and quality of life show improvement for all patients between pre- and post-operation, regardless of group. The study concludes the two months physiotherapeutic rehabilitation protocol for total knee arthroplasty is as effective as the three months protocol, as both reached the same goals and results
103

Avaliação funcional retrospectiva de pacientes com tumor ósseo tratados com endoprótese / Retrospective functional evaluation of bone tumor patients treated with endoprosthesis

Prada, Lídia Maria 19 September 2017 (has links)
Nesta dissertação avaliamos o pico de torque da máxima contração voluntária de diferentes grupos musculares do membro operado e não operado em pacientes submetidos à ressecção de tumores ósseos e reconstrução com endopróteses do joelho (17 pacientes) ou do quadril (11 pacientes). Foi comparado o torque do lado acometido com o não acometido e, no caso do joelho, a redução do torque das ressecções distais do fêmur (8 pacientes) com as proximais da tíbia (9 pacientes). A redução do torque dos grupos musculares responsáveis pelo movimento das articulações estudadas foi definida como a proporção da diferença entre o lado acometido e o não acometido em relação ao torque do lado não acometido. No joelho houve redução do torque extensor de 77,5% e flexor de 29,1%. Não foi encontrada diferença na redução dos torques extensor e flexor entre ressecções proximais da tíbia e distais do fêmur apesar da necessidade de reinserção do ligamento patelar no primeiro caso. A reabilitação apresentou correlação inversa e moderada com a redução do torque, mostrando a importância da atividade física para manutenção ou melhora da força muscular. Nas reconstruções do quadril houve redução de todos os grupos musculares avaliados, sendo maior para os abdutores (39%), que foi o único grupo muscular reinserido à prótese com sutura. Apesar dos resultados funcionais bons e excelentes obtidos pelo questionário Musculoskeletal Tumor Society Rating Scale (MSTS) houve redução significativa da força para todos os grupos musculares estudados. Este estudo é original na medida em que o estudo das forças musculares é pouco explorado nas endopróteses do joelho e inédito nas endopróteses do quadril. Concluímos que não houve diferença significativa da redução da força muscular quando comparadas ressecções do fêmur distal e da tíbia proximal e que a altura da patela, o surgimento de complicações e o tempo de seguimento não influenciaram a redução da força muscular nas ressecções do joelho, mas o maior tempo de reabilitação melhorou o desempenho muscular. Nas reconstruções do quadril a redução da força ocorreu em todos os grupos musculares avaliados, sendo maior para os abdutores (39%). A redução do torque abdutor mostrou ter correlação com os resultados obtidos na avaliação do questionário MSTS. / In this dissertation, the peak torque of the maximum voluntary contraction of different muscle groups of the operated and non-operated limbs was measured in patients submitted to bone tumors resection and reconstruction with knee (17 patients) or hip (11 patients) endoprosthesis. The affected side was compared to the contralateral side and the torque deficit ratio was used to compare distal femur and proximal tibia resections. The torque deficit ratio was defined as the ratio of the torque difference between the affected and non-affected sides in relation to the non-affected side torque. Extension torque deficit ratio of the knee was 77,5% and flexor torque deficit ratio was 29,1%. No difference was found in extensor and flexor torque deficit ratios between distal femur (8 patients) and proximal tibia (9 patients) resections despite the need for reinsertion of the patellar ligament in the latter case. Rehabilitation presented an inverse and moderate correlation with torque deficit ratio, showing the importance of physical activity for maintenance or improvement of muscle strength. Strength reduction was seen in all muscle groups after hip reconstruction and was more intense in abductor muscles (39,0%), which was the only muscle group reinserted to the prosthesis with suture. Despite the good and excellent functional results obtained from the Musculoskeletal Tumor Society Rating Scale (MSTS), there was a significant strength reduction of all studied muscle groups. The need for muscular reinsertion and biomechanical factors did not affect the torque deficit ratio. Muscular strength has been scarcely studied after implantation of knee endoprosthesis and never after hip endoprosthesis which turns this study original. We concluded that there was no significant difference of muscle strength deficit when comparing distal femur and proximal tibia resections and that patellar height, complication upset, and follow-up time did not influence muscle strength in the knee resections, but longer rehabilitation time improves muscle performance in knee reconstructions. In hip reconstructions, the force reduction occurred in all muscle groups evaluated, being higher for the abductors (39,0%). Abductor torque reduction was shown to correlate with the results obtained in the MSTS questionnaire.
104

Role of receptor activator of nuclear factor kappa B ligand (RANKL) in the modulation of osteolysis in primary and revision total hip arthroplasty

Machado, Gil Daniel da Costa January 2012 (has links)
Tese de mestrado integrado. Bioengenharia. Faculdade de Engenharia. Universidade do Porto. 2012
105

Avaliação do efeito da radiação ultravioleta sobre polietileno de ultra-alto peso molecular usado implantes para artroplastia. / Evaluation of the effect of ultraviolet radiation on ultra high molecular weight polyethylene used implants for arthroplasty.

RIBEIRO, Márcia Cristina de Moraes Reis. 13 April 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-04-13T17:46:55Z No. of bitstreams: 1 MÁRCIA CRISTINA DE MORAES REIS RIBEIRO - DISSERTAÇÃO PPG-CEMat 2014..pdf: 1739612 bytes, checksum: 483de315f077aaf3a1be5bb9bddc6639 (MD5) / Made available in DSpace on 2018-04-13T17:46:55Z (GMT). No. of bitstreams: 1 MÁRCIA CRISTINA DE MORAES REIS RIBEIRO - DISSERTAÇÃO PPG-CEMat 2014..pdf: 1739612 bytes, checksum: 483de315f077aaf3a1be5bb9bddc6639 (MD5) Previous issue date: 2014-07-16 / O polietileno de ultra alto peso molecular (PEUAPM) é um polímero com excelentes propriedades físicas e mecânicas tendo como mais notáveis a sua inércia química, a lubricidade, resistência impacto e resistência a abrasão. Exibe um papel relevante no sucesso na Artroplastia Total de Joelho (ATJ) e Artroplastia Total de Quadril (ATQ). A Artroplastia se caracteriza pela substituição da articulação natural por uma articulação artificial. As articulações artificiais são formadas por um conjunto de componentes, sendo fabricados de matéria prima metálica ou cerâmica e um componente, normalmente feito em PEUAPM, que é interposto entre componentes metálicos. Alguns fatores contribuem para um maior desgaste do componente de polietileno. Os componentes fabricados em polietileno PEUAPM não possuem fotoestabilizadores. E em inspeções realizadas em fabricantes e distribuidores destes produtos foi observado que durante seu processamento fabril e comercialização eles não são adequadamente protegidos da iluminação direta. As características consideradas importantes para o desempenho in vitro destes dispositivos estão definidas em normas técnicas, mas muitas destas normas somente recomendam determinados requisitos considerados importantes do ponto de vista técnico. Atualmente a área de materiais de uso em saúde trabalha em regulamentos que visam instituir os requisitos mínimos para registro de implantes ortopédicos. Desta forma, este trabalho propôs avaliar as possíveis alterações de componentes fabricados em polietileno de ultra alto peso molecular utilizados em procedimentos cirúrgicos de artroplastia e joelho e quadril, exposto a radiação ultravioleta. O trabalho foi dividido em 4 grupos: grupo 1 (material não exposto a UV); grupo 2 (material exposto a UV por 1h); grupo 3 (material exposto a UV por 24h) e grupo 4 (material exposto a UV por 48h). Todas as amostras foram caracterizadas por Difração de Raio X (DRX), Espectroscopia de Absorção de Infravermelho por Transformada de Fourier (FTIR), Microscopia Ótica (MO), Microscopia Eletrônica de Varredura (MEV) com mapeamento por EDS e Microscopia de Força Atômica (AFM) com o intuito de avaliar as possíveis degradações do PEUAPM submetidos a radiação UV. Os resultados demonstraram que a exposição do polímero a radiação UV em todos os tempos testados neste trabalho promoveu alterações nas amostras, pois foi observado, principalmente, nos ensaios de DRX e EDS que ocorreu respectivamente, um discreto aumento da cristalinidade do material e diminuição no percentual de oxigênio. Desta forma, pode-se concluir que o aumento da cristalinidade pode, pela ação da radiação UV, afetar nas propriedades do material contribuindo para o aumento do desgaste e diminuição do tempo de vida útil do implante. / The polyethylene, ultra high molecular weight (UHMWPE) is a polymer with excellent physical and mechanical properties with the most notable its chemical inertness, lubricity, impact resistance and abrasion resistance. Displays a relevant role in the successful Total Knee Arthroplasty (TKA) and Total Hip Arthroplasty (THA). The arthroplasty is characterized by replacement of the natural joint with an artificial joint. Artificial joints are formed by a set of components, being manufactured from metal or ceramic raw material and a component normally done in UHMWPE, which is interposed between the metal components. Some factors contribute to increased wear of the polyethylene component. Components manufactured in polyethylene UHMWPE not have photostabilizers. And inspections on manufacturers and distributors of these products was observed that during its industrial processing and marketing they are not adequately protected from direct light. Characteristics considered important for the in vitro performance of these devices are set in technical standards, but many of these standards only recommend certain requirements considered important from a technical standpoint. Currently the area of materials for use in healthcare working on regulations that seek to establish the minimum requirements for registration of orthopedic implants. Thus, this study aimed to evaluate the possible changes of components manufactured in polyethylene, ultra high molecular weight used in surgical procedures and knee arthroplasty and hip, exposed to ultraviolet radiation. The work was divided into 4 groups: group 1 (material not exposed to UV); group 2 (material exposed to UV for 1 h); group 3 (material exposed to UV for 24 h) and group 4 (material exposed to UV for 48 h). All samples were characterized by X-Ray Diffraction (XRD), Absorption Spectroscopy Fourier Transform Infrared (FTIR), optical microscopy (OM), scanning electron microscopy (SEM) with EDS mapping and Atomic Force Microscopy (AFM) in order to evaluate the possible degradation of UHMWPE subjected to UV radiation. The results showed that exposure of the polymer to UV radiation at all times tested in this study modified the samples, it was observed mainly in the experimental XRD and EDS which occurred respectively a slight increase in crystallinity and decrease in the percentage oxygen. Thus, it can be concluded that the increase in crystallinity can by the action of UV radiation, affect the material properties contributing to increased wear and reduced useful life of the implant.
106

Reconstrução acetabular em enxerto ósseo liofilizado humano ou bovino associado a dispositivo de reforço

Rosito, Ricardo January 2006 (has links)
O presente estudo é uma coorte contemporânea de 49 pacientes (51 quadris) submetidos à reconstrução acetabular com enxerto ósseo liofilizado humano ou bovino, picado e impactado, associado a reforço acetabular. Foi realizado no Serviço de Ortopedia e Traumatologia do Hospital de Clínicas de Porto Alegre (HCPA), no período de maio de 1997 a fevereiro de 2005. Os pacientes foram divididos em dois grupos: o grupo 1 (n=26) foi composto pelos que receberam enxerto ósseo liofilizado de origem humana e o grupo 2 (n=25), por aqueles que receberam enxerto de origem bovina. O reforço utilizado em todos os casos foi da MDT® (SP-Brasil). O tempo médio de seguimento foi de 55 e 49 meses respectivamente. Os enxertos ósseos purificados e liofilizados foram produzidos pelo Banco de Tecidos do HCPA. A análise clínica baseou-se no escore de Merle d’Aubigné e Postel e a radiográfica, nos critérios de Conn et al.para osteointegração dos enxertos que avalia a radiolucência, a densidade, a formação de trabeculado ósseo e a migração do componente. Não foram encontradas diferenças clínicas ou radiográficas relevantes entre os grupos, obtendo-se em torno de 88,5 e 76% de integração do enxerto. Estes resultados são comparáveis aos relatados na literatura com o uso de enxerto alógeno congelado e estimulam a continuidade da pesquisa sobre enxertos liofilizados de origem humana e bovina. / Background: this is a cohort trial of 49 patients (51 hips) submitted to revision acetabular component of total hip arthroplasty, using impacted human and bovine freeze-dried cancellous bone grafts and reinforcement device. The study was carried out in the Hospital de Clínicas de Porto Alegre (HCPA) from May 1997 to February 2005. The aim of the study was to compare clinical and radiographic graft incorporation capability between human and bovine freeze-dried bone grafts. Patients and Methods: the patients were divided in two groups: Group 1 (n=26) was composed by those receiving human grafts, and Group 2 (n=25), bovine grafts. The follow-up average was 55 and 49 months. The grafts were purified and freeze-dried at the Tissue Bank of the HCPA.The clinical analysis was based on the score of Merle d’Aubigné and Postel; and the radiographic analysis in an established score based in Conn’s et al. criteria for radiographic bone incorporation. Results: no clinical or radiographic differences were observed between the groups and both groups showed an overall rate of 88.5 and 76% of graft integration. Conclusion: these results are comparable to those reported in the literature with the use of deep-frozen grafts. Therefore, bovine and human freeze-dried grafts can be safely and adequately used in acetabular revision in total hip arthroplasty.
107

Por uma tecnologia de cuidado integral ao paciente da fila de espera para artroplastia total primária de joelho no Instituto Nacional de Traumatologia e Ortopedia / For a technology of comprehensive care to the patient waiting list for primary total knee arthroplasty at the National Institute of Traumatology and Orthopedics

Almeida, Katharine Fonseca de January 2011 (has links)
Made available in DSpace on 2015-11-27T12:41:17Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 994.pdf: 2336673 bytes, checksum: 6d0726493ecc8756ee93a9b0547e17b4 (MD5) Previous issue date: 2011 / Made available in DSpace on 2015-12-07T13:21:42Z (GMT). No. of bitstreams: 2 994.pdf: 2336673 bytes, checksum: 6d0726493ecc8756ee93a9b0547e17b4 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2011 / Fundação Oswaldo Cruz. Escola Nacional de Saúde Pública Sergio Arouca. Rio de Janeiro, RJ, Brasil. / O objeto do estudo em questão é o cuidado ao paciente que está na fila de espera para um procedimento ortopédico de alta complexidade, a artroplastia total primária dejoelho no Instituto Nacional de Traumatologia e Ortopedia. Atualmente o tempo aproximado de espera na instituição para a realização desse procedimento, após a indicação pelo especialista, é de 44 meses. A proposta inicial foi o desenho, com aparticipação dos profissionais envolvidos, de um dispositivo de intervenção pela equipe multidisciplinar ao paciente que está aguardando na fila, contribuindo para o aperfeiçoamento de práticas de assistência integral, humanizada e voltadas paraqualidade do cuidado. Esse cuidado integral ao sujeito em sofrimento deve ser entendido, principalmente, como se opondo à visão reducionista focada na doença, tão presente no modelo biomédico assistencial hegemônico. A abordagem metodológica foiclínico-qualitativa apoiada na Psicossociologia Francesa e na Psicodinâmica do Trabalho. Foram realizadas entrevistas individuais semi-estruturadas com os pacientesda fila de espera e posteriormente entrevistas em grupo semi-estruturadas com a equipe multidisciplinar do Centro de Atenção Especializada do Joelho, baseadas na problematização do material produzido nas entrevistas com os pacientes. Adotamos como principais categorias analíticas a noção de cuidado ao paciente, o sofrimento vivenciado por eles, a integralidade em saúde, o imaginário e a produção do sentidopelos sujeitos da pesquisa. Embora não tenha sido possível construir com a equipe uma proposta de cuidado integral ao paciente na fila de espera para a artroplastia total primária de joelho, consideramos ter obtido resultados relevantes que permitirão contribuir para o seu alcance no futuro. Entre esses resultados pode-se destacar a visibilidade conferida à situação dos pacientes na fila, bem como, ao modo como os profissionais, especialmente os médicos, representam os pacientes e suas demandas e a forma como concebem seu processo de trabalho e as possibilidades de atenção aospacientes.
108

Análise histológica da neoformação óssea com o uso de enxerto bovino liofilizado / Histological analysis of bone neoformation with the use of lyophilized bovine xenograft

Ribeiro, Tiango Aguiar January 2015 (has links)
A artroplastia é, em última análise, a opção final para o tratamento da osteoartrose. Com o aumento do número de indicações deste procedimento, a troca (artroplastia total de quadril de revisão – ATQR) dos componentes também passou a ser mais frequente. Os defeitos ósseos ou falhas ósseas são problemas que podem ser encontrados quando se realiza uma ATQR e, eles devem ser reparados, ou seja, o quadril do paciente a receber outra prótese necessita ser reconstruído. Para isto a grande maioria das técnicas empregadas requer o uso de enxerto ósseo e, devido a este motivo este tecido tem se tornado um dos tecidos mais transplantados na atualidade. Porém a demanda para utilização dos enxertos, na maioria provenientes de bancos de tecidos ósseos, tem aumentado, mas o suprimento é insuficiente. Portanto faz-se necessário a busca por novas tecnologias e alternativas aos bancos de tecidos. O enxerto bovino liofilizado (EBL) é uma destas opções, sua produção em livre demanda suas características físicas e químicas semelhantes ao osso humano e sua boa repercussão clínico-radiológica o torna uma alternativa viável. Este estudo tem o objetivo de verificar e quantificar a neoformação óssea com o uso do EBL pelo uso da avaliação histológica. Realizou-se um estudo de casos de Julho de 2000 a Abril de 2013 no Hospital de Clínicas de Porto Alegre (HCPA), onde se incluíram sujeitos que foram submetidos a uma cirurgia prévia cirurgia de ATQR onde foi utilizado o EBL os quais internaram posteriormente para uma segunda cirurgia de ATQR não relacionada a falha do enxerto e sim a falha da prótese. Nesta segunda cirurgia realizou-se a biópsia óssea. Quatorze sujeitos foram analisados, sendo 64,3% do sexo feminino. A média de idade dos pacientes foi 52,36±18,55. Neoformação óssea estava presente em 85,7% dos sujeitos, e constituiu 61,79% da área total de matriz óssea. O diagnóstico de absorção do EBL estava presente em 12 sujeitos. Uma forte correlação de proporção inversa foi constatada pelo teste de Pearson entre a porcentagem de osso neoformado e a porcentagem de EBL na área total de matriz óssea (p=0,001). Nenhuma resposta inflamatória foi encontrada. Concluiu-se que houve neoformação óssea adequada na grande maioria dos casos sendo o EBL uma boa estrutura osteocondutora, podendo ser considerado uma alternativa aos outros enxertos ósseos no tratamento das falhas ósseas. / Arthroplasty is, ultimately, the final option for the treatment of osteoarthritis. With the increasing number of indications of this procedure, the exchange (total hip arthroplasty revision surgery- THARS) also became more frequent. The bone defects are problems that can be encountered when conducting a THARS and this defect must be repaired, in other words, the patient's hip needs to be rebuilt before receive a new prosthesis. Most of techniques used to rebuild requires the use of bone graft, and because of this reason, this tissue has become one of the most transplanted tissues today. However the demand for the use of grafts, mostly from bone tissue banks, has increased, but the supply is insufficient. Therefore it is necessary to search for new technologies and alternatives to tissue banks. The bovine lyophilized xenograft (BLX) is one of these options; the production on free demand, its physical and chemical characteristics similar to human bone and its good clinical and radiological outcomes makes it a viable alternative. The aim of this study was to verify and quantify new bone formation by the histological analysis in subjects who received the BLX. This was a case series from July 2000 to April 2013 realized in the Hospital de Clínicas de Porto Alegre. This study included patients who underwent to a THARS where was used the BLX, which later was admitted to a second THARS surgery, not related to the xenograft failure but a mechanical failure of the implant. In this second surgery was performed the bone biopsy. Fourteen subjects were analyzed, 64.3% were female. The average age of patients was 52.36 ± 18.55 years. New bone formation was present in 85.7% of subjects, and constituted 61.79% of the total bone matrix. The diagnosis of BLX absorption was present in 12 subjects. A strong inverse correlation founded by the Pearson's test was observed between the proportion of new bone and the proportion of BLX (p=0.001). No inflammatory response was found. Was concluded that there was suitable bone formation in the vast majority of the cases, as well as the BLX is a good osteoconductive scaffold and can be considered an alternative to other bone graft in the treatment of bone defects.
109

Reconstrução acetabular em enxerto ósseo liofilizado humano ou bovino associado a dispositivo de reforço

Rosito, Ricardo January 2006 (has links)
O presente estudo é uma coorte contemporânea de 49 pacientes (51 quadris) submetidos à reconstrução acetabular com enxerto ósseo liofilizado humano ou bovino, picado e impactado, associado a reforço acetabular. Foi realizado no Serviço de Ortopedia e Traumatologia do Hospital de Clínicas de Porto Alegre (HCPA), no período de maio de 1997 a fevereiro de 2005. Os pacientes foram divididos em dois grupos: o grupo 1 (n=26) foi composto pelos que receberam enxerto ósseo liofilizado de origem humana e o grupo 2 (n=25), por aqueles que receberam enxerto de origem bovina. O reforço utilizado em todos os casos foi da MDT® (SP-Brasil). O tempo médio de seguimento foi de 55 e 49 meses respectivamente. Os enxertos ósseos purificados e liofilizados foram produzidos pelo Banco de Tecidos do HCPA. A análise clínica baseou-se no escore de Merle d’Aubigné e Postel e a radiográfica, nos critérios de Conn et al.para osteointegração dos enxertos que avalia a radiolucência, a densidade, a formação de trabeculado ósseo e a migração do componente. Não foram encontradas diferenças clínicas ou radiográficas relevantes entre os grupos, obtendo-se em torno de 88,5 e 76% de integração do enxerto. Estes resultados são comparáveis aos relatados na literatura com o uso de enxerto alógeno congelado e estimulam a continuidade da pesquisa sobre enxertos liofilizados de origem humana e bovina. / Background: this is a cohort trial of 49 patients (51 hips) submitted to revision acetabular component of total hip arthroplasty, using impacted human and bovine freeze-dried cancellous bone grafts and reinforcement device. The study was carried out in the Hospital de Clínicas de Porto Alegre (HCPA) from May 1997 to February 2005. The aim of the study was to compare clinical and radiographic graft incorporation capability between human and bovine freeze-dried bone grafts. Patients and Methods: the patients were divided in two groups: Group 1 (n=26) was composed by those receiving human grafts, and Group 2 (n=25), bovine grafts. The follow-up average was 55 and 49 months. The grafts were purified and freeze-dried at the Tissue Bank of the HCPA.The clinical analysis was based on the score of Merle d’Aubigné and Postel; and the radiographic analysis in an established score based in Conn’s et al. criteria for radiographic bone incorporation. Results: no clinical or radiographic differences were observed between the groups and both groups showed an overall rate of 88.5 and 76% of graft integration. Conclusion: these results are comparable to those reported in the literature with the use of deep-frozen grafts. Therefore, bovine and human freeze-dried grafts can be safely and adequately used in acetabular revision in total hip arthroplasty.
110

Estudo comparativo entre dois métodos de reabilitação fisioterapêutica na artroplastia total do joelho: protocolo padrão do IOT x protocolo avançado / Comparative study between two physiotherapeutic rehabilitation methods in total knee arthroplasty: IOT standard protocol and advanced protocol

Adriana Lucia Pastore e Silva 13 December 2006 (has links)
Este estudo compara dois protocolos de reabilitação fisioterapêutica - um com três meses de duração (protocolo padrão IOT) e outro com dois meses (protocolo avançado) - para evidenciar a real necessidade de um tempo prolongado de reabilitação em 31 pacientes submetidas a artroplastia total do joelho. O estudo é prospectivo e randomizado e a faixa etária avaliada está entre 60 e 76 anos. As pacientes são avaliadas no pré-operatório e após o tratamento com avaliação clínica (escala de dor, Knee Society Score, SF-36 e goniometria) e avaliação de força (avaliação isocinética) para comparação dos protocolos. A análise estatística dos valores da escala de dor, do Knee Society Score, da amplitude de movimento, do pico de torque muscular e da avaliação da qualidade de vida (SF-36) demonstra que todas as pacientes obtêm melhora quando comparamos o pré e pós-operatório, independente do grupo. Conclui-se que o protocolo de reabilitação fisioterapêutica com dois meses de duração para o pós-operatório de artroplastia total do joelho mostra ser eficaz, alcançando os mesmos objetivos e resultados que o protocolo com três meses de duração / The present study compares two physiotherapeutic rehabilitation protocols - one lasting three months (standard IOT protocol), the other lasting two months (advanced protocol) - to assert the actual need of a prolonged rehabilitation period in 31 cases of patients who went through total knee arthroplasty. The study is prospective and randomized; the age group of evaluated patients is between 60 and 76 years-old. In order to compare the two protocols, patients are evaluated before surgery and after treatment, by means of clinical evaluation (pain scale, Knee Society Score, SF-36 and goniometry) and isokinetic strength test. Statistical analyses of results from pain scale, Knee Society Score, movement amplitude, muscular torque peak and quality of life show improvement for all patients between pre- and post-operation, regardless of group. The study concludes the two months physiotherapeutic rehabilitation protocol for total knee arthroplasty is as effective as the three months protocol, as both reached the same goals and results

Page generated in 0.0666 seconds