• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 38
  • 11
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 49
  • 49
  • 38
  • 20
  • 14
  • 13
  • 11
  • 11
  • 8
  • 8
  • 8
  • 8
  • 7
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Estudo da influência das características químicas e microestruturais nas propriedades mecânicas de sistemas totalmante cerâmicos

Dias, Alexandre Henrique de Moura [UNESP] 29 November 2002 (has links) (PDF)
Made available in DSpace on 2014-11-10T11:09:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-11-29Bitstream added on 2014-11-10T11:57:35Z : No. of bitstreams: 1 000200299.pdf: 5347548 bytes, checksum: bfbf67b7f74116d15c5f3e17aa246b7d (MD5) / O propósito deste estudo foi analisar a influência das características químicas e microestruturais nas propriedades mecânicas dos materiais de infra-estrutura (A –lPSEmpress 2 e B - In Ceram Alumina) e de recobrimento estético (C – Empress cerâmico e D -Vitadur Alfa) de sistemas totalmente cerâmicos. Para determinação dos valores dos parâmetros de propriedades mecânicas foram utilizados os ensaios de flexão em quatro pontos, cisalhamento (com e sem ciclagem) e microdurezasuperficialVickers. As superfícies das cerâmicas foram analisadas por dífração de raios X emicroscopia eletrônica de varredura (MEV). Após os ensaios mecânicos, as superfícies de fratura dos materiais A e B e as interfaces A/C e B/Dforam analisadas quimicamente por EDX e microestruturalmente por MEV. Os resultados foram consistentes com a literatura, onde os materiais são compostos de fases cristalinas e C e D são vítreos. Os valores médios de resistência à fratura por flexão foram coerente com os compostos presentes nas cerâmicas e os desvios padrões foram relacionadosà quantidade de defeitos microestruturais. Os tratamentos estatísticos não paramétrico de Kruskal-Wallis e Weibulldestes dados mostraram uma diferença estatisticamente significante do conjunto A/C em relação aos demais materiais, e do B/Dcom o material B. Não foi observada diferença significativa entre os valores de resistência à fratura obtida nos ensaios de cisalhamento estático e por ciclagem mecânica para um mesmo sistema. No ensaio semciclagern mecânica, verificou-se umamaior resistência adesiva para o sistema A/C, que foi associado à formação de interface química / The purpose of this study was 10 analyze the influence of chemical and microestrutural characteristics in the mechanical properties of infrastructurematerials (A –IPS Empress 2 and B - ln Ceram Alumina) and of aesthetic revestiment (C –ceramic Empress and D -VltadurA!fa) of systems all ceramic. Inorder to determine the parameters values for mechanical properties involving 4 points flexural oftest in four points were used, shear bond strength (with andwithout cyclic loading) and Vickers superficialmicrohardness. The ceramic surfaces were analyzed trough X-raydiffraction and scanning electron microscopy (SEM). After the mechanical test, the fracture surfaces of the materials A and B andthe interfaces A/C and B/D were analyzed chemically by EDS andmicrostruturally by SEM. The results complied with the literature,where A and B materials consists of crystalline phases and C andD are vitreous.The average flexure fracture strength values were consistenwiththe present compositions in the ceramic and the standard deviations were related to amount of microstrutural defects. Non parametric statistical treatment refering to Kruskal-Wallis and Weibull and involving these e data evidenced a significant difference in the A/C group compared to the remaining materials, and of B/D group compared to Bmaterial. It was not evidenced significant difference between the fracture strength values originated form the test of static shear bond strength and cyclic loading for one same system. ln the test without cyclic loading, evidenced greater adhesive strengthfor the A/C system andthis was associated to the formation of chemical interface
32

Avaliação da rugosidade superficial de restaurações estéticas e do esmalte adjacente após o uso de diferentes instrumentos rotatórios de acabamento e polimento

Silva, Regina Célia Santos Pinto [UNESP] 03 July 1997 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:31Z (GMT). No. of bitstreams: 0 Previous issue date: 1997-07-03Bitstream added on 2015-01-26T13:30:17Z : No. of bitstreams: 1 000036229.pdf: 3107646 bytes, checksum: d0806c4df33a9f0925861dab953b0da8 (MD5) / O propósito do presente trabalho foi avaliar in vitro a rugosidade superficial de dois materiais restauradores estéticos, resina composta TPH (Dentsply) e compósito poliácido modificado VariGlass (Dentsply) e também do esmalte adjacente a estas restaurações, após procedimentos de acabamento com ponta diamantada e brocas multilaminadas de oito e 12 lâminas e polimento com ponta verde de silicone, pasta diamantada e a associação das duas. Foram selecionados 114 dentes sendo que seis deles foram deixados intatos para se avaliar a rugosidade do esmalte sem nenhum tipo de tratamento e os demais receberam preparos cavitários no terço médio da face vestibular, sendo restaurados conforme instruções do fabricante. Os corpos de prova foram armazenados em água destilada, em estufa a 370, por 24 horas, após o que receberam acabamento e polimento. Após estes procedimentos os corpos de prova foram analisados num rugosímetro Perthometer S8P (Perthen, Mahr, Germany) e os dados obtidos foram analisados estatisticamente. De acordo com os resultados pudemos verificar que a resina composta apresenta menor rugosidade que o cimento de ionômero vítreo; que o esmalte adjacente às restaurações tomou-se mais liso que o esmalte íntegro: as brocas multilaminadas mostraram menores valores de rugosidade quando comparadas às pontas diamantadas, com diferença estatisticamente significante; nenhum dos procedimentos de acabamento e polimento empregados foi satisfatório para o cimento de ionômero vítreo, que apresentou os maiores valores de rugosidade média e são necessárias novas investigações sobre acabamento e polimento desses materiais, assim como pesquisas sobre o próprio material para que possamos vir a ter restaurações com melhor qualidade de superfície / The purpose of this in vitro study was to evaluate the surface texture of two aesthetic restorative materials: a composite resin TPH (Dentsply) and a polyacid-modified composite VariGlass (Dentsply). as well as the adjacent enamel to these restorations, after polishing and finishing procedures with diamond points, with eight and twelve blade trimming and finishing burs, with a green silicone tip, with a diamond polishing past and with an association of the last two procedures. We have selected 114 teeth, six of wich received neither polishing nor finishing procedures, with the purpose of evaluating the enamel roughness. The remaining teeth received cavity preparations on the buccal surfaces and were restored following the manufacture' s instructions. The specimens were kept for 24 hours in destiled water at 37° C and only then polishing and finishing procedures were performed. Profilometric analyses were carried out using a Perthometer S8P (Perthen, Mahr, Germany) and the collected data were statísticaly analysed. The results showed that the composite resin presented less surface roughness than the polyacid-modified composite, that the enamel adjacent to the restorations became smoother than the sound enamel; that the eight and twelve blade burs promoted surfaces less roughen than the diamond points, with statisticaly meaningful difference. None of the finishing and polishing procedures demonstrated to be satisfactory for the glass ionomer cement. Researches concerning the finishing and polishing of this material are necessary, as well as the material itself: so that better surface texture restorations could be obtained
33

Avaliação da eficiência de adesão de um cimento resinoso autocondicionante (self-adhesive) sobre esmalte e dentina: efeito termociclagem e condicionamento dental : estudo in vitro

Fernandes Júnior, Virgílio Vilas Boas [UNESP] 27 May 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-05-27Bitstream added on 2014-06-13T20:51:27Z : No. of bitstreams: 1 fernandesjunior_vvb_me_sjc.pdf: 534033 bytes, checksum: dc3fecf909acf51fb45b0235288dbddc (MD5) / O objetivo do trabalho foi analisar in vitro a eficiência de adesão através de ensaio de microtração, de um cimento autocondicionante (self-adhesive), sobre esmalte e dentina, com e sem tratamento prévio da superfície dental, antes e após termociclagem. Foram utilizados 56 terceiros molares, 28 para esmalte e 28 para dentina, divididos em 6 grupos experimentais e 2 controle. O cimento resinoso autocondicionante selecionado para os grupos experimentais foi: Rely-X Unicem (3M ESPE/ St. Paul, MN, EUA), e para os grupos controle o Variolink II (Ivoclar Vivadent, AG, Schaan, Liechtenstein) (VR), cimento de cura dual não autocondicionante. Os dentes dos grupos experimentais foram subdivididos quanto à aplicação direta do cimento sobre a superfície dental (R), com o condicionamento ácido (RAC) e com condicionamento ácido e aplicação de sistema adesivo (RACAS). Blocos de resina composta previamente polimerizados foram cimentados à superfície dental. Os conjuntos dente-cimento-bloco receberam cortes paralelos ao longo eixo dos dentes para a confecção dos palitos. O ensaio de microtração com aparelho de ensaio universal (EMIC) foi utilizado para analisar a resistência adesiva dos cimentos avaliados. Os corpos de prova após o ensaio foram analisados mediante microscópio óptico para analise do modo de fratura. Para a análise estatística do μTBST, foi utilizado ANOVA 3 fatores com teste de comparação múltipla de Tukey a 5%, considerando os fatores cimento resinoso, região e armazenagem. Os resultados mostraram diferença estatística existente entre R aplicado diretamente sobre a superfície dental e os demais grupos. Os grupos RACAS e VR apresentaram maiores médias de resistência adesiva para os grupos dentina, respectivamente antes e após termociclagem e o cimento RAC para os grupos esmalte. A termociclagem não diminuiu significativamente os valores de resistência... / The objective of this research was to analyze in vitro , the adhesive efficiency of a self - etching cement trough microtensile test , over enamel and dentine , with and with out previous treatment of dental surface , before and after thermocycling. Were used 56 third molars, 28 for enamel and 28 for dentine, divided in 06 experimental groups and 02 control groups. The resin cement self - etching selected for the experimental groups was: Rely X Unicem (3M ESPE/ St. Paul, MN, EUA), and for the control groups: Variolink II (Ivoclar Vivadent, AG, Schaan , Liechtenstein) (VR), dual healing cement not self etching. The teeth of the experimental groups were subdivided in groups as the direct application of cement over the dental surface (R) without previous treatment (RAC), with the acid etching and with acid etching and application of adhesive system (RACAS) e (VR). Composed resin blocks polymerized previously were cemented on dental surface. The sets tooth- cement-block received parallel cuts in long axis of the teeth to make the tooth picks. The micro tensile test was done with the universal apparatus (EMIC) to analyze the resistance efficiency of the evaluated cements. The specimens were analyzed after the test by optical microscope to analyze the mode fracture. For the statistics analyses of μTBST, were used ANOVA 3 factors with multiple comparison test of Tukey 5%, considering the factors resin cement, region and storage. The results showed present statistics difference between R applied directly on dental surface and the other groups. The groups RACAS and VR presented superior average of adhesive resistance for dentine groups before and after thermocycling, and the RAC cement for the enamel groups before and after thermocycling. The thermocycling did not low significantly the adhesive resistance values, just for the RACAS group. By the results we can conclude that the self etching... (Complete abstract click electronic access below)
34

Análise do efeito clareador e da sensibilidade pós operatória utilizando diferentes materiais clareadores e fontes de luz

Almeida, Letícia Cunha Amaral Gonzaga de [UNESP] 20 March 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-03-20Bitstream added on 2014-06-13T20:11:58Z : No. of bitstreams: 1 gonzaga_lca_me_araca.pdf: 772898 bytes, checksum: a490bb43e9735c3542d945420fe1e996 (MD5) / O clareamento dental tem sido empregado por muitos profissionais por acreditarem ser uma técnica segura e eficaz. Contudo, com o objetivo de acelerar e potencializar o processo clareador, o uso de peróxidos em altas concentrações está sendo associado a fontes de calor e/ou luz. A combinação de materiais clareadores altamente concentrados com as fontes luminosas pode elevar a temperatura da estrutura dental e a penetração do peróxido, em detrimento de possíveis danos pulpares. Assim, os reais benefícios e as conseqüências biológicas desta opção de tratamento ainda são pouco conhecidos. Objetivos: comparar a efetividade clareadora, a estabilidade de cor e sensibilidade ocorridas em pacientes que receberam clareamento caseiro e de consultório com ou sem o emprego de fontes luminosas. Métodos: 40 pacientes foram selecionados e divididos aleatoriamente em quatro grupos de acordo com o tratamento clareador recebido: I- clareamento caseiro com peróxido de carbamida a 10% (PC), por 4 horas diárias, durante 3 semanas; os outros três grupos receberam 3 sessões de clareamento de consultório com peróxido de hidrogênio a 35% (PH) , com 3 aplicações de 10 minutos em cada sessão, como segue: II- sem emprego de luz, III- Lâmpada halógena, IV-LED/laser. A cor dos dentes foi avaliada utilizando a escala Vita Classical e a ocorrência de sensibilidade foi obtida por questionário feito aos pacientes, que relataram a intensidade, duração e localização da sintomatologia. As avaliações foram realizadas antes do clareamento, depois da primeira e terceira semana do clareamento com PC ou da primeira e terceira sessões de PH, bem como aos 7, 30 e 180 dias decorridos do término do tratamento. Resultados: O teste Kruskal-Wallis mostrou que a alteração de cor ocorreu de forma semelhante em todos os grupos e em todos os períodos de análise. Não foi observado retorno da cor... / The dental bleaching has been used by many professionals which believe to be a safe and effective treatment. However, to accelerate the bleaching process, the use of peroxide in high concentrations has been associated with heat or light sources. The combination of highly concentrated bleaching materials with light sources, raises the temperature of the tooth structure and penetration of peroxide which may cause pulpal damage. Thus, the real benefits and the biological consequences of this treatment are still largely unknown. Objectives: to compare the effectiveness, color stability and sensitivity occurred in patients who received at-home and in-office bleaching treatments, with or without the use of light sources. Methods: 40 patients were selected and randomly divided into four groups, according to bleaching treatment received: I- home-bleaching with 10% carbamide peroxide (CP) 4 hours/day for 3 weeks; the other three groups received 3 sessions of in-office bleaching with 35% hydrogen peroxide (HP), with 3 applications of 10 minutes in each session, as follows: II- without light source, IIIHalogen Lamp, IV-LED/laser. Tooth shade was evaluated using the Vita Classical Shade Guide before bleaching, after first and third week of at-home bleaching, after first and third session of in-office bleaching; after 1 week, 1 and 6 months after the end of the treatment. The teeth color was evaluated using the Classical Shade Guide, and the occurrence of sensitivity was obtained by questionnaire made to patients, who reported the intensity, duration and location of symptoms. The evaluations were conducted before the bleaching, after the first and third week of bleaching with PC or first and third sessions of PH and 7, 30 and 180 days after the end of treatment. Results: The Kruskal-Wallis test showed no significant differences among groups at all times (p>0.01), and there was no color rebound... (Complete abstract click electronic access below)
35

Eficiência da ativação química no clareamento dental em consultório

Travassos, Alessandro Caldas [UNESP] 12 June 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-06-12Bitstream added on 2014-06-13T20:11:59Z : No. of bitstreams: 1 travassos_ac_me_sjc.pdf: 586258 bytes, checksum: 33dc8b58f9cef135ba461a19dd57985d (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo comparou cinco tipos de agentes químicos catalisadores adicionados ao Peróxido de Hidrogênio a 35%, quanto à sua eficiência no clareamento em consultório. Utilizaram-se cento e vinte dentes bovinos, cujas coroas e raízes foram desgastadas, adquirindo as dimensões de um incisivo central humano. Os espécimes foram divididos através de dois cortes longitudinais, desprezando-se as metades linguais. As metades vestibulares receberam profilaxia com jato de bicarbonato, limpeza em ultra-som e condicionamento ácido na porção dentinária. A seguir, os espécimes foram armazenados em recipientes contendo solução de café solúvel a 25%, por duas semanas. Terminado o período de escurecimento, foi realizada mensuração inicial da cor obtida, através do aparelho Easy Shade, que permitiu quantificá-la através do método CIE Lab*. Os espécimes foram divididos em seis grupos, correspondentes ao ativador químico: a) controle (CON); b) cloreto férrico (CF); c) sulfato ferroso (SF); d) gluconato de manganês (GM); e) cloreto de manganês (CM); f) extrato de raiz de amora (RA). Cada grupo recebeu três aplicações, por dez minutos, do gel clareador formado pela mistura de três gotas do Peróxido para uma gota de ativador. Em seguida, foi realizada uma nova mensuração da cor. Os testes de analise de variância e Tukey ('alfa'= 5%) mostraram diferenças estatisticamente significantes para os valores do parametro 'delta'E dos géis GM, CM e RA para com o gel CON. Concluiu-se que a presença dos ativadores químicos GM, CM e RA resultou... / This study compared the capacity of five catalyser chemical added to 35% Hidrogen Peroxide to intensify the in-office dental bleaching. One hundred and twenty bovine teeth had been used and their crowns and roots had been consumed to acquire the dimensions of a human central incisor. The specimens had been divided trough one longitudinal cut, disdaining the lingual halves The facial halves had received a bicarbonate spurt prophylaxis, ultrasound cleaned and acid etching on the dentin portion. The specimens had been stored in containers contends 25% coffee solution, for two weeks. Finished the period of blackout, initial measurement of the gotten color was carried trough the Easy shade device, that it allowed to quantify it trough the method CIE Lab*. The samples had been divided in six groups, related to the chemical activator: a) control (CON); b) ferric chloride(CF); c) ferrous sulphate (SF); d) manganese gluconate (GM); e) manganese chloride(CM); f) extract of malberry root (RA). Each group received three applications of the bleaching gel, formed by the mixture of three Peroxide drops for one activator drop, during ten minutes. A new color measurement was carried trough, then. The tests of variance analysis and Tukey ('alfa' = 5%) had shown significant differences for the values of parameter 'delta'E of the gel GM, CM e RA for the gel COM. It was concluded that the presence of the chemical activators GM, CM e RA resulted in a significantly better bleaching that group CON.
36

Avaliação do manchamento causado por pigmentos provenientes de bebidas em dentes clareados

Magalhães, Juliana Gonçalves [UNESP] 04 July 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-07-04Bitstream added on 2014-06-13T19:30:39Z : No. of bitstreams: 1 magalhaes_jg_me_sjc.pdf: 371580 bytes, checksum: 3caf22b87aca79162c50e9a0db7ffaf0 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar a alteração de cor causada pela imersão de dentes humanos em extrato de açaí e solução de café após a conclusão de clareamento caseiro e após 15 dias do término do tratamento clareador. Sessenta incisivos humanos íntegros foram divididos em grupos de 20 dentes cada: GI - dentes não clareados; GII - dentes clareados por peróxido de carbamida 10%, oito horas por dia, durante 21 dias ; GIII - dentes clareados pela mesma técnica do GII e a seguir imersos por 15 dias em saliva artificial.Após esse tratamentos os grupos foram subdivididos em GIa, GIc, GIIa, GIIc, GIIIa e GIIIc, (n=10), de acordo com a solução que foram imersos durante 50 h, açai(a)ou café(c). A cor dos dentes foi avaliada antes e após imersão, utilizando-se um espectrofotômetrointre-bucal, e a alteração de cor foi calculada pela fórmula 'delta' Eab=[('delta'L*)'POT.2'+('deltaa*)'POT.2'+('delta'b*)'POT.2]'POT.0,5'.Os resultados do teste ANOVA evidenciaram que os dois corantes utilizados não diferiram entre si (p<0,05), e o teste de Tukey mostrou que a copndição GII foi significantemente diferente das demais. Concluiu-se que tanto o açaí quanto o café podem manchar dentes clareados ou não e que dentes submetidos ao clareamento e imediatamente expostos a esses corantes possui um maior potencial de manchamento. / The purpose of this study was to evaluate the color change caused by immersion of human teeth in acai extract and coffee solution right after completion of home dental bleaching and 15 days after completion of the bleaching treatment. Sixty sound human incisors were assigned to groups of 20 teeth each: GI - nonbleached teeth; GII - teeth bleached with 10% carbamide peroxide, 8 hours/day, during 21 days; GIII - teeth bleached using the same bleaching regimen described for GII and then immersed in artificial saliva for 15 days.After these treatments,the groups were subdivided in GIa, GIc, GIIa, GIIc, GIIIa and GIIIc (n=10),according to the solution in which the teeth were immersed during 50 hours, i.e.,acai (a) or coffe(c). Tooth color was evaluated before and after immersion using an intraoral spectrophotometer, and color change was calculated by the following equation 'delta' Eab=[('delta'L*)'POT.2'+('deltaa*)'POT.2'+('delta'b*)'POT.2]'POT.0,5'. The results of ANOVA showed that both pigments did not differ significantly from each other (p>0,05) and Tukeyþs test showed that GII was significatly different from the other groups. In conclusion, both acai extract and coffee solution may stain bleached or nonbleached teeth alike. Teeth submitted to bleaching regimens and immediately exposed of these pigments have a higher staining potential.
37

Eficiência de três cimentos de ionômero de vidro como dissipadores de cargas em bases de restaurações de resina composta: análise por meio da extensometria elétrica

Rocha, Daniel Maranha da [UNESP] 11 July 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-07-11Bitstream added on 2014-06-13T18:07:51Z : No. of bitstreams: 1 rocha_dm_me_sjc.pdf: 304438 bytes, checksum: e92fc33799e2997ce037c7a5b7a8994b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo neste estudo foi analisar, por meio da extensometria elétrica, a eficiência dos cimentos de ionômero de vidro convencionais e modificados por resina composta como dissipadores de cargas em restaurações de resina composta. Em matrizes de poliuretano foram colados, dois strain gauges, de modo que suas superfícies superiores tangenciassem a parede de fundo da matriz de ambos os lados (esquerdo e direito). Foram confeccionados 10 corpos de prova em cada grupo num total de 40, sendo no Grupo 1: preenchimento total com resina composta microhíbrida (Opallis); Grupo 2: colocação de uma base de 3mm de cimento de ionômero de vidro convencional (Maxxion R) e preenchimento com resina composta; Grupo 3: colocação de uma base de 3mm de cimento de ionômero de vidro para forramento (Vidrion F) e preenchimento da cavidade com resina composta, e; Grupo 4: colocação de uma base de 3mm de cimento de ionômero de vidro modificado por resina composta (Vitremer) e preenchimento da cavidade com resina composta. Os corpos de prova foram posicionados numa máquina universal de ensaios (EMIC) na qual sofreram uma carga de 50 N no período de 30 s, a uma freqüência de 10 Hz, totalizando 300 leituras por strain gauge. Os dados dos dois sensores foram captados por um amplificador de sinais elétricos e, posteriormente, analisados por um software Os dados coletados foram analisados estatisticamente pelos testes ANOVA e Tukey (p? 0,05), e não apresentaram diferenças estatisticamente significantes. Pode-se concluir que a presença do CIV como material de base de restaurações de resina composta, bem como os tipos de cimento utilizados não apresentaram alterações nos valores de microdeformação. / The aim of this study was to use the strain gauge method to analyze in vitro the efficiency of conventional and resin modified glass ionomer cements as occlusal load dissipaters in composite restorations. Two strain gauges were bonded to polyurethane matrixes with cyanoacrylate adhesive, so that their top surfaces would be tangential to the bottom wall of the matrix on both sides (left and right). For each group, 10 test specimens were made, 40 specimens in total. In Group 1: the cavities were completely filled with microhybrid composite resin; Group 2: filled with conventional glass ionomer cement and microhybrid composite; Group 3: filled with conventional glass ionomer cement for lining and microhybrid composite; Group 4: filled with resin modified glass ionomer cement and microhybrid composite. The test specimens were placed in a universal test machine EMIC, and subjected to a 50 N load for 30 s. Monitoring was done ten times every second, thus providing 300 readings per strain gauge. Data from the two strain gauges were amplified and transferred with an electrical signal amplifier, and then recorded to be analyzed later by special AqDados software. The data collected were statistically analyzed by ANOVA and the Tukey tests (p? 0,05). The mean microdeformation values found for the experimental groups showed no statistically significant difference. From the data obtained in this study, it could be inferred that the presence of GIC as a base material for resin composite restorations, and also the types of cements used presented no significant alterations in the microdeformation values.
38

Avaliação in vitro da translucidez de dois sistemas cerâmicos metal-free: In-Ceram x Empress 2

Augusto, Jean Carlo Duarte [UNESP] 31 August 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-08-31Bitstream added on 2014-06-13T19:51:24Z : No. of bitstreams: 1 augusto_jcd_me_arafo.pdf: 977646 bytes, checksum: be6532503de67df201b656b4dc100b31 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os sistemas cerâmicos metal-free são materiais odontológicos restauradores indiretos com excelentes propriedades ópticas, mecânicas e biológicas. As indicações destes materiais têm uma relevância clínica fundamental nos dias atuais, visto que, as expectativas dos pacientes por excelentes resultados estéticos são cada vez maiores. Conhecer amplamente as propriedades destes materiais é importante na evolução da área odontológica. O objetivo deste trabalho foi realizar, in vitro, uma comparação da propriedade óptica de translucidez de dois sistemas cerâmicos metal-free amplamente utilizados nos consultórios odontológicos (In-Ceram e Empress 2) comparando grupos de estudo que representassem quadros próximos às situações clínicas, produzindo amostras dos materiais estudados na espessura em que são indicados pelos fabricantes, ou seja, 0,5 mm para a infra-estrutura ou coping do In-Ceram, e 0,8 mm para a infra-estrutura do Empress 2. Foi produzido um grupo experimental com o material de Empress 2 na espessura de 0,5 mm, para ter-se um parâmetro de comparação dos dois materiais na mesma espessura. Nesta fase, todos os corpos de prova foram submetidos às leituras de translucidez, com o emprego do aparelho Jouan. Os corpos de prova foram, em uma etapa seguinte, cobertos pela cerâmica de estratificação para compararmos a situação clínica final de uma restauração indireta. Produziram-se corpos de prova com a espessura de 1,5 mm, e nova leitura da translucidez foi realizada. Esses corpos de prova receberam então o tratamento de glazeamento na face em que haviam sido cobertos com a cerâmica de estratificação, e foi realizada a última leitura da translucidez destes materiais. Os resultados, segundo a metodologia empregada, mostraram que, o Sistema Empress 2 apresenta índices translucidez superiores ao In-Ceram. Quando comparados os materiais de... / All-ceramic systems are indirect restoring materials with excellent optical, mechanical and biological properties. The use of those materials have a fundamental clinical relevance nowadays, since the patients expectations for best esthetical results are increasing. Deep knowledge of these materials properties is very important to odontology area evolution. The objective of this work was to make an in vitro comparison on translucency optical property of two all-ceramic systems often used at dental offices (In-Ceram and Empress 2) when searching for excellence on esthetical results. This work tried to compare studying groups that represented characteristics approximate to clinical situations, producing samples of studied materials at thickness recommended by manufacturer's, that is, 0,5 mm for the core materials or coping of In-Ceram, and 0,8 mm for the Empress 2. It was produced an experimental group with the Empress 2 material at thickness of 0,5 mm, in order to provide a comparison parameter for both materials at the same thickness. At this phase, all the disc specimens were submitted to quantitative measurement of translucency, using Jouan equipment. In the next phase, the disc specimens were veneered with stratification ceramic so we could compare the final clinical situation of an indirect restoration. Disc specimens were produced with thickness of 1,5 mm, and a new measurement of translucency was made. These samples then received a glazing cycle on the side that were veneered with stratification ceramic, and finally we made the last measurement of translucency on these materials. The results, according to adopted methodology, showed that the Empress 2 System presents greater translucency than In-Ceram System. When the core materials were compared, one can establishes that: translucency index of Empress 2 (0,5 mm) > Empress 2 (0,8 mm)... (Complete abstract, click electronic address below)
39

Citotoxicidade de agentes clareadores para dentes tratados endodonticamente sobre fibroblastos gengivais

Fernandes, Aletéia Massula de Melo [UNESP] 29 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-29Bitstream added on 2014-06-13T20:31:48Z : No. of bitstreams: 1 fernandes_amm_me_sjc.pdf: 332962 bytes, checksum: f4c47a3efef5e5b260cbd7ef4a2f1c60 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A proposta deste trabalho foi avaliar a citotoxicidade do peróxido de hidrogênio liberado por agentes clareadores, utilizados para clareamento de dentes tratados endodonticamente, sobre cultura de fibroblastos provenientes do tecido gengival humano (FMM1). As células foram cultivadas em DMEM e quando apresentaram-se em quantidade suficiente e entre a quinta e décima passagens foram plaqueadas em placas de 96 poços onde receberam os meios de cultura condicionados de acordo com os grupos experimentais (n=12): G1- Perborato de Sódio + água; G2- Perborato de sódio + Peróxido de Carbamida 20%; G3- Peróxido de Carbamida 20%; G4- Perborato de Sódio + Peróxido de Hidrogênio 35%; G5- Peróxido de Hidrogênio 35%. O grupo controle (n=12) correspondeu à curva de crescimento e viabilidade celular, onde as células não receberam tratamento. O ensaio com MTT foi realizado nos períodos de 24 e 48 horas para avaliar a viabilidade celular. Paralelamente, mediu-se em espectrofotômetro a quantidade de peróxido de hidrogênio liberado nas condições experimentais. Os dados foram analisados através dos testes de ANOVA e Tukey. Todos os grupos experimentais apresentaram diferença significativa em relação ao controle. O tempo de avaliação mostrou diferença estatística, exceto para o G1 (PS + H2O). Concluiu-se que: todos os agentes clareadores testados foram citotóxicos, diminuindo significantemente o metabolismo e viabilidade celular; a associação do perborato de sódio com água destilada foi o agente clareador mais tóxico e o peróxido de carbamida 20% o menos tóxico. / The propose of this study was to evaluate the cytotoxicity from five bleaching agents, used for the technique of intracanal bleaching, on human gingival fibroblasts (FMM1). The cells were cultivated in DMEM and when they were presented in enough amount and between the fifth and tenth passages they were placed in plates of 96 wells; where they received the conditional culture according to the experimental groups (n=12): G1- SP + H2O; G2- SP + CP20%; G3- CP20%; G4- SP + HP35%; G5- HP35%. The control group (n=12) corresponded to the curve of cell growth and viability, where the cells didn’t receive any treatment. The MTT assay was carried through in the periods of 24 and 48 hours to evaluate the cellular viability. The amount of set free hydrogen peroxide in the experimental conditions was also measured in a spectrophotometer. The data were submitted to statistical analysis of variance and Turkey’s test. All the experimental groups presented significant difference in comparison to the control. The evaluation time showed statistical difference, except for the G1 (SP + H2O). Conclusion: all the bleaching agents had showed cytotoxicity effects, reducing significantly the cell metabolism and viability; the association of sodium perborate with distilled water was the most toxic bleaching agent and carbamide peroxide 20% the least.
40

Penetração de peróxido de hidrogênio 38% no interior da câmara pulpar de dentes bovinos e humanos com ou sem restauração submetidos ao clareamento externo

Camargo, Samira Esteves Afonso [UNESP] 03 August 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-08-03Bitstream added on 2014-06-13T20:31:52Z : No. of bitstreams: 1 camargo_sea_me_sjc.pdf: 698707 bytes, checksum: 21ecc468a433f0633cef989558394cc9 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Acredita-se que a penetração de peróxido de hidrogênio através do esmalte e dentina pode causar danos à polpa. A proposta deste trabalho foi avaliar a quantidade de peróxido de hidrogênio no interior da câmara pulpar de dentes bovinos e humanos com ou sem restauração, após clareamento pela técnica de consultório. Os dentes foram seccionados 3mm à junção amelo-cementária e divididos em dois grupos: A (setenta terceiros molares humanos) e B (setenta incisivos laterais bovinos) que foram subdivididos em: A1 e B1 restaurados com resina composta (Esthetic-X, Dentsply), A2 e B2 com CIV (Vidrion-R, SSWhite), A3 e B3 com CIV modificado por resina (CIV-MR) (Vitremer, 3M); A4, A5, B4 e B5 não foram restaurados. No interior da câmara pulpar de todos os dentes foi colocado tampão acetato. Os subgrupos A1 a A4 e B1 a B4 foram expostos ao peróxido de hidrogênio 38% (Opalescence XtraBoost, Ultradent) por 40 min. Os subgrupos A5 e B5 permaneceram em água deionizada por 40 min. O tampão acetato foi transferido a um tubo de ensaio reagindo com corante violeta leucocristal e peroxidase. A densidade óptica da solução foi avaliada em espectrofotômetro, os valores de absorbância convertidos em microgramas de peróxido e submetidos aos testes de Dunnett, Kruskal-Wallis, ANOVA e Tukey (5%). Verificou-se maior penetração de peróxido nos dentes bovinos (0,79l0,61æg) e humanos (2,27l0,41æg) restaurados com CIV-MR. A penetração do agente clareador foi maior em dentes humanos para qualquer situação experimental. Concluiu-se que a penetração de peróxido depende do material restaurador e que dentes humanos são mais susceptíveis à penetração do agente clareador para o interior da câmara pulpar do que dentes bovinos. / It is believe that externally applied bleachings agents could penetrate into the pulp chamber.This study was conducted to evaluate pulp chamber penetration of peroxide bleaching agent in human and bovine teeh, after office bleach technique. All the teeth were sectioned 3mm apical of the cemento-enamel junction and were divided into 2 groups: A (70 third human molars) and B (70 bovine lateral incisor) that were subdivided in: A1 and B1 restored using composite resin (Esthetic-X, Dentsply), A2 and B2 using glass ionomer cement (Vidrion-R, SSWhite), A3 and B3 using resin-modified glass ionomer cement (Vitremer, 3M); A4, A5, B4 and B5 were not restored. Acetate buffer was placed in the pulp chamber and the treatment agent was applied for 40 min as follow: A1 to A4 and B1 to B4 38% hydrogen peroxide exposure and A5 and B5 immersion into distilled water. The buffer solution was transferred to a glass tube where leuco crystal violet and horseradish peroxidase were added, producing a blue solution. The optical density of the blue solution was determined determined by spectrophotometer and converted into microgram equivalents of hydrogen peroxide. Data were submitted to ANOVA and Dunnett, Kruskal-Wallis, and Tukey tests (5%). A higher level of hydrogen peroxide penetrated into the pulp chamber in resin-modified glass ionomer cements groups, bovine (0,79l0,61æg) and human (2,27l0,41æg). The bleaching agent penetration was higher in human teeth for any experimental situation. The penetration of the hydrogen peroxide depend on restorative materials and that human teeth are more susceptible to penetration of bleaching agent into the pulp chamber than bovine teeth.

Page generated in 0.0571 seconds