• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 52
  • 30
  • 5
  • 4
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 118
  • 26
  • 24
  • 17
  • 15
  • 15
  • 14
  • 12
  • 10
  • 10
  • 9
  • 9
  • 9
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

An evaluation of efficiency of phenylenediamines as corrosion inhibitors for ASTM-A-179 steel in 1.0 N hydrochloric acid at room temperature

Al-Zubail, Saleh Abdullah January 1987 (has links)
No description available.
62

Alterações histopatológicas de stents metálicos no endotélio coronariano \"in vivo\" / Histopathological abnormality in coronary artery bare stent metal \"in vivo\"

Amaral Neto, Othon 02 March 2012 (has links)
Duas técnicas invasivas para o tratamento da doença aterosclerótica coronariana oclusiva firmaram-se ao longo dos anos: revascularização cirúrgica do miocárdio e angioplastia transcutânea com stents metálicos. O estudo visa comparar as alterações histopatológicas causadas por stents metálicos coronarianos fabricados com a superliga de composição química em porcentagem em peso cromo 20%, tungstênio 15%, níquel 10% e cobalto restante, designada ASTM F.90, revestidos, ou não, com carbeto de silício pelo processo de asperção térmica originando uma superfície hidrofílica. Stents com espessura das hastes entre 80 a 90 nm, área das células entre 1,4 a 2,1 mm² e relação metal-artéria de 13 a 19%, em pacientes reestenosantes que sofreram posteriormente revascularização cirúrgica do miocárdio, com aqueles não submetidos à angioplastia prévia. Foram determinados dois grupos: grupo I ou grupo controle, pacientes que sofreram revascularização cirúrgica do miocárdio sem angioplastia prévia de qualquer natureza; grupo II pacientes submetidos à revascularização cirúrgica do miocárdio, após reestenose intra-stent coronariana. Pacientes de ambos os grupos foram avaliados rotineiramente quanto à indicação e risco cirúrgico e durante o procedimento convencional da revascularização cirúrgica do miocárdio utilizando circulação extracorpórea, antes de realizar a anastomose do enxerto vascular na coronária, amostras contendo pequenos fragmentos de endotélio foram retiradas juntamente com fragmentos dos stents, enviadas para análise histopatológica e produção de laminas coradas com H-E. Observou-se a presença de arterite crônica caracterizada por infiltrado mononuclear em conjunto com fenômeno de proliferação fibroblástica e de musculatura lisa naqueles pacientes que apresentavam reestenose intra-stent, sendo mais intenso no local do stent. A visualização das superfícies dos stents em escala nanometrica (MFA) é de suma importância para análise estrutural das próteses, avaliando irregularidades nas superfícies recobertas das hastes dos stents. A persistência de arterite crônica coronariana avaliada por infiltrado linfomononuclear e proliferação de fibrocolágeno foi constatada em pacientes reestenosantes. / Two invasive techniques for the treatment of occlusive coronary atherosclerosis disease were signed over the years: coronary artery bypass surgery and transcutaneous angioplasty with bare metal stent. The study attempts to compare the histopathological abnormality caused in patients with implantation of bare metal stent in coronary made with: Chromium 20%, Tungsten 15%, Nickel 10% and Cobalt remainder, ASTM F.90 alloy for surgical implant applications, and covered with a thin layer of amorphous silicon carbide, or not, and its total or partial obstruction, after undergoing coronary artery bypass grafting, with those who had coronary artery bypass surgery with no previous angioplasty. Two groups were studied: group I, or control group, patients who underwent coronary artery bypass grafting without previous angioplasty of any kind; group II of patients undergoing coronary artery bypass surgery after coronary-stent restenosis. Patients in both groups were evaluated for the indication and surgical risk; was done routinely during the procedure of conventional coronary artery bypass grafting with cardiopulmonary bypass. Before performing the anastomosis in coronary vascular graft, a small fragment of the endothelium was removed along whit a fragment of the stent, and sent for analysis with hematoxilin-eosin. The presence of chronic inflammatory coronary reaction was detected, mediated by mononuclear cells with phenomenon of fibroblast and smooth muscle proliferation in patients presenting in-stent restenosis. It w coronary reaction as also observed that the inflammatory and proliferative process is more intense at the site of stent implantation. The analysis of surface of the stents used atomic force microscopy proved to be an important method for the surface analysis for stents, and showed on nanometric scale an irregular coverage of silicon carbide. In conclusion, in the patients with restenosis in-stent occurs persistence of chronic inflammation with mononuclear cells and process of fibroblast proliferation.
63

ESTUDO ELETROQUÍMICO E DA CORROSÃO DO AÇO ASTM 285 GRAU C, NAS REGIÕES DE SOLDA E DA ZONA TERMICAMENTE AFETADA, EM SOLUÇÕES DE LICOR BRANCO, UTILIZADO EM DIGESTORES DA INDÚSTRIA DE PAPEL E CELULOSE, E SEUS PRINCIPAIS COMPONENTES / ESTUDO ELETROQUÍMICO E DA CORROSÃO DO AÇO ASTM 285 GRAU C, NAS REGIÕES DE SOLDA E DA ZONA TERMICAMENTE AFETADA, EM SOLUÇÕES DE LICOR BRANCO, UTILIZADO EM DIGESTORES DA INDÚSTRIA DE PAPEL E CELULOSE, E SEUS PRINCIPAIS COMPONENTES

D’avila, Ariel Leandro 25 August 2016 (has links)
Made available in DSpace on 2017-07-21T20:43:49Z (GMT). No. of bitstreams: 1 Dis_Ariel_final.pdf: 5083548 bytes, checksum: acac140ede5eeafdd769aa58a612e863 (MD5) Previous issue date: 2016-08-25 / This work aims to study the electrochemical steel ASTM A285 Grade C and the same welded with coated electrode AWS E 7018 in the solution of industrial white liquor used in pulp and paper industry by the Kraft method. Samples were withdrawn by electroerosion into three regions: the base metal (BM), the heat affected zone (HAZ) and at the weld metal (WM). Corrosion rates of the three metal regions were determined in 8°C, 16°C, 24°C, 35°C, 42°C, 50°C and 60°C temperature. The values of corrosion rates were compared with the BM, ZTA and WM corrosion rates in electrolytic solutions of the main chemical components of the industrial white liquor in the same temperature range. These solutions were 0,1 mol/L of Na2SO4; 2.276 mol/L of NaOH; 0.126 mol/L of Na2S; 0.128 mol/L of Na2CO3 and simulated white liquor composed of the above solutions with the same molar concentrations. The BM to 24°C, industrial white liquor aerated presented corrosion rate of 0.022 mm/year, 0.045 mm/year for the HAZ and 0.032 mm/year for the WM. It was observed that the HAZ corrosion rates were higher than BM and WM in all solutions studied. Lower corrosion rates were in Na2CO3, followed by NaOH, Na2S, simulated white liquor and finally with the highest corrosion rates in white liquor industry. All solutions are presented alkaline, except sodium sulfate, and it was observed that the three regions are passivated when compared to a reference solution of 0.1 mol/L Na2SO4, and aerated with a pH between 6.0 to 6.5. This passivation film are complex chemical composition due to the presence in solution of OH- HS- ion. From the corrosion potentials of BM in each solution and the pH values it was found that the BM region is passivated according iron Pourbaix diagram in water. Chronoamperometry and voltammetric studies showed that these passivation films that promote greater protection against corrosion, they are solubilized in NaOH solution, simulated white liquor and industrial white liquor when submitted to anodic polarization in potential near at +2.0 V versus saturated calomel electrode. In Na2S and Na2CO3 solution was observed the formation of thick deposits on the surface of BM and when analyzed by EDS was observed the presence of phases such as oxides, sulfides and possibly iron carbonate. / Este trabalho tem como objetivo o estudo eletroquímico do aço ASTM A285 Grau C soldados com eletrodo revestido AWS E 7018 em meio de licor branco industrial empregado na indústria de papel e celulose pelo método Kraft. As amostras foram retiradas por eletroerosão em três regiões: metal base (MB), região termicamente afetada pela soldagem (ZTA) e pelo metal de solda (MS). As taxas de corrosão das três regiões metálicas foram determinadas em temperaturas de 8°C a 60°C. Os valores das taxas de corrosão foram comparados com as taxas de corrosão do MB, ZTA e MS em soluções eletrolíticas dos principais componentes químicos do licor branco industrial, no mesmo intervalo de temperatura. Estas soluções foram de 0,1 mol/L de Na2SO4; 2,276 mol/L de NaOH; 0,126 mol/L de Na2S; 0,128 mol/L de Na2CO3 e em um licor branco simulado composto pelas soluções acima com as mesmas concentrações molares. O MB, a 24°C, em licor branco industrial, aerado, apresentou taxa de corrosão de 0,022 mm/ano, 0,045 mm/ano para a ZTA e 0,032 mm/ano par o MS. Observou-se que as taxas de corrosão da ZTA foram superior a do MB e MS em todas as soluções estudadas. As taxas de corrosão mais baixas foram em Na2CO3, seguido pela solução de NaOH, Na2S, licor branco simulado e finalmente, com as maiores taxas de corrosão, em licor branco industrial. Todas as soluções apresentaram-se alcalinas, exceto a de sulfato de sódio, e constatou-se que as três regiões encontravam-se passivadas quando comparada a uma solução de referência de 0,1 mol/L de Na2SO4,aerada e com pH entre 6,0 a 6,5. Estes filmes de passivação são de composição química complexa devido a presença em solução de íon OH- e HS-. A partir dos potenciais de corrosão do MB em cada solução e dos valores do pH foi verificado que a região do MB encontra-se passivado segundo o diagrama de Pourbaix de ferro em água. Estudos voltamétricos e de cronoamperometria mostraram que estes filmes de passivação, que promovem uma maior proteção contra a corrosão, são solubilizados em meio de NaOH, licor branco simulado e no licor branco industrial quando submetidos a polarizações anódicas em potenciais próximos de +2,0 V versus eletrodo de calomelano saturado. Em solução de Na2S e Na2CO3 foi observado à formação de depósitos espessos sobre a superfície do MB e quando analisados por EDS, observou-se a presença de fases como de óxidos, sulfetos e possivelmente carbonato de ferro.
64

Efeito da corrosão atmosférica marinha sobre os aços ASTM Grau 80, Grau 100 e Grau 120, utilizados na montagem de lingas de corrente. /

Marques, Rodrigo Pereira January 2019 (has links)
Orientador: Eduardo Norberto Codaro / Resumo: O presente trabalho tem por objetivo avaliar o efeito da corrosão atmosférica marinha sobre os aços ASTM Grau 80, Grau 100 e Grau 120, que são utilizados na montagem de lingas de corrente destinadas à movimentação de cargas. Os problemas atribuídos à deterioração desses materiais são comuns e frequentes, pois basicamente em todos os ramos da atividade econômica há materiais que necessitam ser transportados. E para analisar o comportamento destes aços frente à corrosão, foram realizados ensaios eletroquímicos e ensaios de imersão por perda de massa utilizando uma solução contendo NaCl a 3,56% (em massa) que simula a atmosfera marinha em ambientes laboratoriais. Os resultados dos ensaios de OCP (Potencial em Circuito Aberto) e de Polarização de Tafel revelaram que o processo de corrosão é controlado pela difusão de O2 dissolvido neste meio. Pode-se concluir que os valores de OCP e de Ecorr (potencial de corrosão) obtidos foram muito similares entre si para todas as regiões do elo analisadas (solda, corpo e deformação). A região do corpo demonstrou maior resistência à corrosão, obtendo os maiores valores médios de resistência de polarização (Grau 80: 10,14 kΩ; Grau 100: 12,61 kΩ; e Grau 120: 11,74 kΩ). As densidades de corrente de corrosão (Icorr) observadas são baixas e da mesma ordem de magnitude (abaixo de 7µA/cm2). Nos ensaios de imersão, observou-se que a perda de massa relativa das amostras, após os 10 dias de permanência na solução, foi mínima (entre 0,05 e 0,08 %/cm2), i... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
65

Etude approfondie de la cristallisation des carburants et des combustibles, impact des nouvelles bases / In-depth study of transportation fuels crystallization : impact of alternatives sources on the diesel formulation

Kouakou, Cédric 26 September 2014 (has links)
Les industries du raffinage et du transport doivent faire face à une conjoncture marquée par une demande croissante et importante de carburant gazole et à la fois par la Directive 2003/30/EC de l’Union Européenne imposant l'incorporation progressive de sources renouvelables dans les carburants (5,75 % en 2010 à 20 % en 2020, en terme de contenu énergétique). Dans ce contexte, les schémas de raffinage ont été orientés vers la valorisation de plus de coupes lourdes en bases pour la formulation des carburants gazoles et combustibles Fuel–Oil domestique, tandis que l’aspect réglementaire est satisfait en ayant recours à des bases alternatives de type Esters Méthyliques d’Huiles Végétales (EMHV). Cependant, les gazoles moteurs ainsi formulés sont d’avantage exposés aux problématiques de cristallisation en raison de l’accroissement de composés susceptibles de s’y solidifier lors de températures hivernales (principalement les n-alcanes et les Esters Méthyliques d’Acides Gras). Il est par conséquent important de se doter d’un outil d’optimisation de la formulation permettant de prédire la température d’apparition des premiers cristaux, soit leur point de trouble. Dans cette perspective, il a été nécessaire d’acquérir les données expérimentales de transition de phase liquide – solide des Esters Méthyliques d’Acides Gras composants les EMHV, mais également celles des fluides réels (gazoles fossiles, EMHV et leurs mélanges). Les données collectées ont par la suite été comparées aux prédictions résultantes de modèles thermodynamiques se proposant de décrire l’équilibre de phase liquide – solide des gazoles et des EMHV, afin de s’en inspirer pour établir une approche prédictive de calcul des températures de transition de phase des mélanges.En définitive, nous avons reliés les résultats de la modélisation thermodynamique et les mesures du point de trouble réalisées conformément aux normes pétrolières en vigueur en Europe (ASTM D5771et D7689), afin d’établir des corrélations aptes à la prédiction de cette propriété attestant de la tenue au froid des gazoles moteurs. / The concerns about greenhouse effect have encouraged the use of biodiesels to replace petroleum-derived diesel fuel. Indeed, the European Union has issued a Directive 2003/30/EC, which mandates the use of biofuels in a percentage ranging from 5.75% in 2010 to 20.00% in 2020 (calculated on the basis of energy content) for all transportation fuels marketed within the member states. First-generation biodiesels made from vegetable oils or animals fats are blended with petroleum diesel to fuel the engines. Besides, the refining schemes were modified to produce more heavy petroleum cuts in order to satisfy the growing demand of diesel fuel. However, the resulting diesel are more exposed to operability problems as the Fatty Acid Methyl Esters and the heavy normal paraffins may solidified in the tank and filters when the temperature drops down during the winter seasons. Thus the study of the solid-liquid phase equilibria of these blends may be useful to predict the temperature of apparition of the solidified material, known as the cloud point. In this work, we collected the melting data of the pure biodiesel components (Fatty Acid Methyl Esters) and we studied the phase change temperature of real diesel samples (petroleum diesel and biodiesel blends). Then, we have developed a thermodynamic model in order to compute the solid-liquid phase equilibria of all these kind of fluids involved in the diesel fuel formulation. Comparisons were made with the experimental phase change measurements and with the cloud point normalized measurement methods (ASTM D5771 et D7689). Finally, we have correlate the phase change temperature calculated by the thermodynamic model with the normalized cloud point, so as this important data could be obtain by a predictive tool.
66

[en] APPLICATION OF J-INTEGRAL IN STEELS OF DIFFERENT YIELD LIMITS / [pt] APLICAÇÃO DA INTEGRAL-J EM AÇOS DE DIFERENTES LIMITES DE ESCOAMENTO

THAIS MOTTA DA SILVA 28 January 2019 (has links)
[pt] O estudo da resistência à fratura dos materiais é de grande importância para desenvolvimentos de projetos, seleção de materiais e avaliação do comportamento dos materiais perante a presença de um defeito no componente. Há inúmeras normas que envolvem geometrias padronizadas para determinação desta propriedade mecânica, no entanto nem todo componente em serviço possui as mesmas condições encontradas nas geometrias padronizadas, como é o caso de materiais dúcteis empregados em estruturas com espessuras de paredes finas e elevada pressão interna. Nesta dissertação foram estudados dois materiais com diferentes limites de escoamento confeccionados conforme geometria tipo SEN(T) de fixação por garras, a qual não é padronizada pela ASTM. Com isso, foi realizada uma pesquisa com o emprego desta geometria com variação de 0,2 a 0,8 da relação entre a dimensão idealizada inicialmente para a trinca e a largura do corpo de prova, e entalhes laterais com redução de 20 porcento foram confeccionados nos corpos de prova do material mais dúctil. Após, foi realizada a pré-trinca de fadiga e iniciado o ensaio de tenacidade à fratura. Este último foi desenvolvido adotando o método compliance, o qual permite que com apenas um corpo de prova seja realizado descarregamentos parciais permitindo assim a determinação de J e incremento de trinca em cada posição, possibilitando plotar a curva-R Os resultados obtidos determinaram que mesmo com a/W diferente daqueles indicados por norma para levantamento da curva-R, é possível obter uma curva-R para a/W=0,2. Existe uma limitação em aplicar a geometria SEN(T) que não possuem extensa ductilidade. / [en] The study of resistance to fracture of the materials is very important for developing new projects, making materials specifications and also for evaluating materials behaviour under presence of a crack in a component. There are uncountables standards which apply normalized specimens due to determine this mechanical property, however some components in service doesn t act under same conditions as the specimen chosen, for instance ductile materials applied in components with thin thickness and high intern pressure. In this dissertation was studied two diferente of materials with distinct yield limits fabricated according to SEN(T) geometry with clamped fixing, which one is not acceptable by ASTM. Thus, a research has been carried out using this geomerty with a variation of 0,2 to 0,8 of the relation between the idealized initially for the crack and the width of the proof body ratio and side-grooves with 20 percent reducted were made in the specimens with higher ductility. After that, the procedure for doing fatigue pre-crack was initialized, followed by fracture toughness test. This last one was developed adopting the unloading compliance technique, which one allows that more than one aplications of force and displacement can be realized in only one specimen then the value of J and crack extension can be calculated and the R-curve will be plotted. The results obtained showed even with a a/W ratio diferente of those indicated by standards, is possible to constructo a qualified R-curve for a/W=0,2. In additon to the results, there is a limitation in applying a SEN(T) geometry in materials that don t present extensive ductility.
67

Alterações histopatológicas de stents metálicos no endotélio coronariano \"in vivo\" / Histopathological abnormality in coronary artery bare stent metal \"in vivo\"

Othon Amaral Neto 02 March 2012 (has links)
Duas técnicas invasivas para o tratamento da doença aterosclerótica coronariana oclusiva firmaram-se ao longo dos anos: revascularização cirúrgica do miocárdio e angioplastia transcutânea com stents metálicos. O estudo visa comparar as alterações histopatológicas causadas por stents metálicos coronarianos fabricados com a superliga de composição química em porcentagem em peso cromo 20%, tungstênio 15%, níquel 10% e cobalto restante, designada ASTM F.90, revestidos, ou não, com carbeto de silício pelo processo de asperção térmica originando uma superfície hidrofílica. Stents com espessura das hastes entre 80 a 90 nm, área das células entre 1,4 a 2,1 mm² e relação metal-artéria de 13 a 19%, em pacientes reestenosantes que sofreram posteriormente revascularização cirúrgica do miocárdio, com aqueles não submetidos à angioplastia prévia. Foram determinados dois grupos: grupo I ou grupo controle, pacientes que sofreram revascularização cirúrgica do miocárdio sem angioplastia prévia de qualquer natureza; grupo II pacientes submetidos à revascularização cirúrgica do miocárdio, após reestenose intra-stent coronariana. Pacientes de ambos os grupos foram avaliados rotineiramente quanto à indicação e risco cirúrgico e durante o procedimento convencional da revascularização cirúrgica do miocárdio utilizando circulação extracorpórea, antes de realizar a anastomose do enxerto vascular na coronária, amostras contendo pequenos fragmentos de endotélio foram retiradas juntamente com fragmentos dos stents, enviadas para análise histopatológica e produção de laminas coradas com H-E. Observou-se a presença de arterite crônica caracterizada por infiltrado mononuclear em conjunto com fenômeno de proliferação fibroblástica e de musculatura lisa naqueles pacientes que apresentavam reestenose intra-stent, sendo mais intenso no local do stent. A visualização das superfícies dos stents em escala nanometrica (MFA) é de suma importância para análise estrutural das próteses, avaliando irregularidades nas superfícies recobertas das hastes dos stents. A persistência de arterite crônica coronariana avaliada por infiltrado linfomononuclear e proliferação de fibrocolágeno foi constatada em pacientes reestenosantes. / Two invasive techniques for the treatment of occlusive coronary atherosclerosis disease were signed over the years: coronary artery bypass surgery and transcutaneous angioplasty with bare metal stent. The study attempts to compare the histopathological abnormality caused in patients with implantation of bare metal stent in coronary made with: Chromium 20%, Tungsten 15%, Nickel 10% and Cobalt remainder, ASTM F.90 alloy for surgical implant applications, and covered with a thin layer of amorphous silicon carbide, or not, and its total or partial obstruction, after undergoing coronary artery bypass grafting, with those who had coronary artery bypass surgery with no previous angioplasty. Two groups were studied: group I, or control group, patients who underwent coronary artery bypass grafting without previous angioplasty of any kind; group II of patients undergoing coronary artery bypass surgery after coronary-stent restenosis. Patients in both groups were evaluated for the indication and surgical risk; was done routinely during the procedure of conventional coronary artery bypass grafting with cardiopulmonary bypass. Before performing the anastomosis in coronary vascular graft, a small fragment of the endothelium was removed along whit a fragment of the stent, and sent for analysis with hematoxilin-eosin. The presence of chronic inflammatory coronary reaction was detected, mediated by mononuclear cells with phenomenon of fibroblast and smooth muscle proliferation in patients presenting in-stent restenosis. It w coronary reaction as also observed that the inflammatory and proliferative process is more intense at the site of stent implantation. The analysis of surface of the stents used atomic force microscopy proved to be an important method for the surface analysis for stents, and showed on nanometric scale an irregular coverage of silicon carbide. In conclusion, in the patients with restenosis in-stent occurs persistence of chronic inflammation with mononuclear cells and process of fibroblast proliferation.
68

Vliv chemického složení a tepelného zpracování na strukturu a vlastnosti dvoufázových austeniticko-feritických korozivzdorných ocelí / Influence of chemical composition and heat treatment on structure and properties of two-phase austenitic-ferritic stainless steels

Stejskal, Marek January 2018 (has links)
This thesis focused on austenitic-ferritic (duplex) stainless steels and their mechanical and technological properties. The theoretical part includes introduction to chemical composition, structure, heat treatment and properties of these steels. The practical part focuses on influence of casting temperature on technological properties of ASTM A890 Gr4A stainless duplex steel. Furthermore, there is evaluated influence of chemical composition and heat treatment on structure and mechanical properties of different duplex stainless steels.
69

Graphite sheets and graphite gap pads used as thermal interface materials : A thermal and mechanical evaluation

Fältström, Love January 2014 (has links)
The electronic market is continually moving towards higher power densities. As a result, the demand on the cooling is increasing. Focus has to be put on the whole thermal management chain, from the component to be cooled to the ambient. Thermal interface materials are used to efficiently transfer heat between two mating surfaces or in some cases across larger gaps. There are several different thermal interface materials with various application areas, advantages and disadvantages. This study aimed to evaluate thermal and mechanical properties of graphite sheets and graphite gap pads. The work was done in cooperation with Ericsson AB. A test rig based on the ASTM D5470 standard was used to measure the thermal resistance and thermal conductivity of the materials at different pressures. It was found that several graphite sheets and gap pads performed better than the materials used in Ericsson’s products today. According to the tests, the thermal resistance could be reduced by about 50 % for the graphite sheets and 90 % for the graphite gap pads. That was also verified by placing the materials in a radio unit and comparing the results with a reference test. Both thermal values and mechanical values were better than for the reference materials. However, the long term reliability of graphite gap pads could be an issue and needs to be examined further. / Elektronikbranschen rör sig mot högre elektriska effektertätheter, det vill säga högre effekt per volymenhet. Som en följd av detta ökar också efterfrågan på god kylning. Kylningen måste hanteras på alla nivåer, från komponenten som ska kylas, ända ut till omgivningen. Termiska interface material (TIM) används för att förbättra värmeöverföringen mellan två ytor i kontakt med varandra eller för att leda värmen över större gap. Det finns flera olika TIM med olika tillämpningsområden, fördelar och nackdelar. Denna studie gick ut på att utvärdera termiska och mekaniska egenskaper hos grafitfilmer och så kallade ”graphite gap pads” då de används som TIM. Projektet gjordes i sammarbete med Ericsson AB. En testuppställning baserat på ASTM D5470-standarden användes för att utvärdera värmeledningsförmågan och den termiska resistansen hos de olika materialen vid olika trycknivåer. Resultaten visade att flera grafitfilmer och ”gap pads” presterade bättre än materialen som används Ericssons produkter idag. Enligt testerna skulle den termiska resistansen kunna minskas med 50 % för grafitfilmerna och 90 % för ”gap padsen”. Materialens fördelaktiga egenskaper verifierades i en radioenhet där temperaturerna kunde sänkas i jämförelse med ett referenstest med standard-TIM. De nya materialen var mjukare än referensmaterialen och skulle därför inte orsaka några mekaniska problem vid användning.  Den långsiktiga tillförlitligheten för grafitbaserade ”gap pads” måste dock undersökas vidare eftersom de elektriskt ledande materialen skulle kunna skapa kortslutningar på kretskorten.
70

[pt] AVALIAÇÃO DA TENACIDADE E PREVISÕES DE FRATURAS EM MATERIAIS ELASTOPLÁSTICOS / [en] TOUGHNESS EVALUATION AND FRACTURE PREDICTIONS IN ELASTOPLASTIC MATERIALS

EDUARDO ENES COTA 05 October 2020 (has links)
[pt] Compreender como analisar trincas é essencial para a indústria petroquímica evitar qualquer incidente de uma forma econômica. Normas de Integridade Estrutural fornecem procedimentos conservadores para avaliar componentes trincados como tubulações e vasos de pressão. Portanto, previsões de cargas criticas foram calculadas assumindo uma placa com trinca passante seguindo procedimentos dos níveis 2 e 3 da API 579. Para comparação, testes experimentais foram realizados para avaliar o conservatismo da norma em falha por rasgamento dúctil. Além disso, a tenacidade à fratura foi medida por meio do JIc e curva J-R. A técnica usada durante o processo de fratura foi o método de flexibilidade elástica com descarregamento e carregamentos sequenciais. Adicionalmente, efeito de geometria e tipo de carregamento, os quais possuem grande influência nas medições de tenacidade, também foram avaliados usando conceitos da mecânica da fratura elastoplástica. O material utilizado nesse trabalho foi o API 5L X80, que é um aço de Alta Resistencia e Baixa Liga (ARBL) bifásico desenvolvido para tubulações aplicáveis em aguas profundas. Os ensaios experimentais de medição de tenacidade usando corpos de prova SE(B), que possuem média-alta restrição plástica, foram testados seguindo procedimentos da ASTM E1820-17. Já os experimentos usando corpos de prova SE(T), que possuem baixa restrição plástica, foram realizados considerando procedimentos da literatura. / [en] Understanding how to analyze cracks is essential for the petrochemical industry to avoid accidents or incidents in a safe and economical way. Structural Integrity standards provide conservative procedures to assess the actual strength of cracked components like pipes and pressure vessels. Therefore, critical loads predictions were computed on a plate with a through-wall crack following level 2 and 3 of the fitness-for-service guide API 579. For comparison, experimental tests were performed to evaluate the standard conservatism on a ductile tearing type of failure. Furthermore, the fracture toughness of the steel was measured through standard JIc tests and material s resistance curves (J-R curve). The technique used during the fracturing process was the elastic compliance method with unloading/reloading sequences. Additionally, the effects of the specimen s geometry and the type of loading, which can significantly change the value of its toughness, were also analyzed using concepts of elastoplastic fracture mechanics. The material used in this work was the API 5L X80, which is a High Strength Low Alloy (HSLA) dual-phase steel developed for deepwater pipelines. The fracture toughness measurement tests using SE(B) specimens, which have a medium-to-high plastic constraint, followed the ASTM E1820-17 procedures. The experiments with SE(T) specimens, which present a low plastic restriction, considered literature procedures.

Page generated in 0.0597 seconds