• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 107
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 110
  • 38
  • 38
  • 35
  • 35
  • 34
  • 32
  • 29
  • 25
  • 25
  • 24
  • 23
  • 14
  • 14
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Determinação de elementos traço em ligas ferrosas e não ferrosas por espectrometria de absorção atômica com atomização eletrotérmica após complexação e sorção sobre carvão ativo /

Giacomelli, Maria Bertilia Oss January 1999 (has links)
Tese (Doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas. / Made available in DSpace on 2012-10-18T23:20:35Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-09T04:14:12Z : No. of bitstreams: 1 151472.pdf: 5392136 bytes, checksum: 21e7a0b572fe450c58be2e98a7761718 (MD5) / São apresentadas três propostas para pré-concentração e determinação de elementos traço em soluções de aços e ligas metálicas: método em batelada, sistema em fluxo com injetor manual e sistema automático em fluxo. Nos três métodos utilizou-se como agente complexante o sal de amônio do ácido O,O-dietil ditiofosfórico e como adsorvente o carvão ativo. Os analitos são determinados por espectrometria de absorção atômica com atomização eletrotérmica. O Fe (III) é previamente reduzido a Fe (II), forma na qual não é complexado com o agente complexante, não sendo significativamente retido pelo carvão ativo. Os fatores de enriquecimento podem ser modificados processando-se diferentes volumes de amostras o mesmo ocorrendo com os limites de detecção. Os métodos podem ser otimizados para outros elementos e outras ligas além das estudadas, onde o elemento majoritário não forme complexo o com agente complexante. O sistema automático de pré-concentração em linha além de utilizar componentes de fácil obtenção e de preço relativamente baixo, permitiu boa versatilidade na mudança de parâmetros experimentais. Os métodos foram aplicados em amostras certificadas onde apresentaram boa concordância.
22

Investigação da amostragem direta para determinação de elementos traço em carne in natura e em petróleo usando espectrometria de absorção atômica com forno de grafite

Damin, Isabel Cristina Ferreira January 2009 (has links)
Neste trabalho foram desenvolvidos diferentes métodos analíticos para serem aplicados rotineiramente na determinação direta de elementos de interesse em amostras de petróleo e de carne in natura, usando a espectrometria de absorção atômica com forno de grafite (GF AAS). Os métodos foram baseados na análise das amostras mediante introdução direta no forno de grafite (SS-GF AAS), sem nenhum tratamento prévio. Inicialmente foi investigada a possibilidade da determinação direta de níquel, vanádio e chumbo em amostras de petróleo. A fim de contornar as perdas de compostos voláteis, foi investigado o uso de diferentes modificadores químicos (convencional e permanente) e os resultados obtidos foram comparados com HR-CS AAS (espectrômetro de absorção atômica de alta resolução com fonte contínua). As análises de amostras de petróleo em emulsões usando um Forno com filtro (THFA) foram também investigadas para determinação de chumbo. Na segunda parte do trabalho foi investigada a determinação direta de chumbo e cádmio em amostras de carne in natura (amostrada diretamente ou sob a forma de suspensão). Todos os resultados foram satisfatórios para aplicação de rotina, e a comparação entre os resultados obtidos para os métodos propostos e os obtidos com os métodos tradicionais não apresentaram diferenças estatísticas significativas. / The goal of this work was to investigate different methods using graphite furnace atomic absorption spectrometry (GF AAS) for direct determination of elements of interest in petroleum and fresh meat to be applied as a rapid routine procedure. The methods were based on analysis of samples weighed directly onto solid sampling platforms and introduced into a transversely heated solid sampling graphite tube, without previous treatment. In the first moment it was investigated of the possibility of direct determination of nickel, vanadium and lead in petroleum. In order to avoid the problem of losses of volatile compounds different chemical modifiers (conventional and permanent) have been investigated and the results obtained were compared with those obtained by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS AAS) by emulsion technique. The analysis of petroleum samples in emulsions using a filter furnace (THFA) was also investigated for lead determination. In the second part of this work it was investigated a method for direct determination of lead and cadmium in fresh bovine meat (solid or slurry sampling). The overall result was very satisfactory for routine application, and the comparison with the conventional methods shows no significant statistical differences between the results.
23

Desenvolvimento de métodos analíticos para determinação de elementos traço em materiais poliméricos utilizando amostragem sólida por espectrometria de absorção atômica em forno de grafite

Duarte, Álvaro Tavares January 2010 (has links)
A União Europeia ao adotar as diretivas: 2002/96/EC — WEEE e a 2002/95/EC — RoHS de modo a minimizar os resíduos equipamentos eletroeletrônicos (WEEE — do inglês: Waste Eletrical Electronic Equipment) e restringir as substancias nocivas (RoHS — do inglês: Restriction of Hazardous Substances) vem causando um grande impacto na rotina de controle de substancias perigosas, incluindo metais taco tóxicos, como chumbo, cadmio e cromo, em todos os materiais que são utilizados nesses equipamentos. Os componentes plásticos são os principais constituintes dos equipamentos eletrônicos e uma potencial fonte de metais taco tóxicos que são adicionados como estabilizantes, corantes e catalisadores. Como esses materiais plásticos são desenvolvidos de modo a serem resistentes a ataques químicos, eles são normalmente difíceis de serem dissolvidos. Sob esta motivação, neste trabalho foram desenvolvidos e otimizados métodos para a determinação de cadmio, chumbo e cromo utilizando a técnica de amostragem direta de sólidos por espectrometria de absorção atômica com forno de grafite. Em todos os procedimentos o foco principal foi a redução de tratamento das amostras, bem como o emprego de soluções padrão aquosas a fim de tornar os métodos mais simples e facilmente aplicáveis a rotina. O use de modificador químico, mistura de paládio e magnésia foi mandatório para estabilizar cadmio e chumbo. As determinações de cromo foram realizadas sem a adição de modificador químico. Calibração versus padrões aquosos Ode ser utilizada para a determinação dos três analitos. Nas determinações de chumbo e de cromo de modo a ter uma maior faixa linear de concentração usou-se o artificio de trabalhar com ou sem fluxo de gás na etapa de atomização. No caso da determinação de cadmio linhas analíticas (228,8 nm e 326,1 nm) com diferentes sensibilidades foram empregadas para ampliar a faixa linear do método. Os limites de detecção foram: 0,7 lig kg-1, 22 prg kg1 e 13 jig kg-1 para cadmio, chumbo e cromo, respectivamente. Materiais de referencia certificados foram utilizados para a validação dos métodos, não havendo diferença significativa entre os valores obtidos e os certificados. Oito amostras de resíduos de equipamentos eletroeletrônicos foram analisadas, estando todas em conformidade com as diretivas WEEE e RoHS. / By adopting the directives 2002/96/EC — WEEE (Waste Eletrical and Electronic Equipment) and 2002/95/EC — RoHS (Restriction of Hazardous Substances) the European Union will cause a great impact on the routine control of hazardous substances, including toxic trace metals, such as lead, cadmium and chromium, in all the materials that are used in this kind of equipment. Plastic components are among the main constituents of electronic equipment and a potential source of toxic trace metals, which are added as stabilizers, catalysts and/or colorant. As these plastic materials are designed to be resistant against chemical attack, they are usually very difficult to bring into solution. Because of that, methods have been developed and optimized in this work for the determination of cadmium, lead and chromium using direct solid sampling graphite furnace atomic absorption spectrometry. The primary aspects in all all method development have been reduction of sample treatment and the use of aqueous Standards for calibration in order to make methods simple and easily applicable in routine. The use of a mixture of palladium and magnesium as a chemical modifier was found to be mandatory for the determination of cadmium and lead, whereas no modifier was necessary for the determination of chromium. Calibration against aqueous standards could be used for all three analytes. In order to increase the linear working range for the determination of chromium and lead, the determination has been carried out with the internal gas flow turned off and on, respectively, during atomization. In the case of cadmium, the analytical lines at 228.8 nm and 326.1 nm, respectively, with significantly different sensitivities were used for that purpose. The detection limits were 0.7 p.g kg', 22 pig kg-1 and 13 !,ig kg-1 for cadmium, lead and chromium, respectively. Certified reference materials were used for validation of the methods, and there was no significant difference between the found and the certified values. Eight samples of residues of electronic equipment have been analyzed, and all of them were within the limits of the directives of WEEE and RoHS.
24

Avaliação do bismuto como padrão interno universal para determinação de chumbo por técnicas espectrométricas atômicas e de massas /

Bechlin, Marcos André. January 2017 (has links)
Orientador: José Anchieta Gomes Neto / Banca: Edilene Cristina Ferreira / Banca: Marisa Spirandeli Crespi / Banca: Joaquim de Araújo Nóbrega / Banca: Márcia Andreia Mesquita Silva da Veiga / Resumo: Este trabalho tem por objetivo a avaliação do bismuto como padrão interno para a determinação de chumbo pelas seguintes técnicas: espectrometria de absorção atômica em chama de alta resolução e fonte contínua (HR-CS FAAS); espectrometria de absorção atômica em chama com fonte de linhas (LS FAAS); espectrometria de absorção atômica em forno de grafite com fonte de linhas (LS GFAAS); espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES); espectrometria de massas com plasma indutivamente acoplado (ICP-MS); vaporização eletrotérmica acoplada a espectrometria de massas com plasma indutivamente acoplado (ETV-ICP-MS) em amostras diversas. Bismuto mostrou-se eficiente na correção de variações instrumentais e interferências matriciais. Para avaliar a exatidão dos métodos desenvolvidos, foram analisados três materiais de referência certificados sendo os valores obtidos concordantes a 95% de confiança com o valor certificado (teste t) quando a padronização interna foi aplicada. Testes de adição e recuperação apresentaram recuperações de 74 - 231% (sem PI) para 96 - 109% (com PI) em HR-CS FAAS; de 52 - 118% (sem PI) para 97 - 109% (com PI) em LS FAAS; de 36 - 125% (sem PI) para 96 - 110% (com PI) em LS GFAAS; de 56 - 91% (sem PI) para 95 - 110% (com PI) em ICP OES; de 36 - 136% (sem PI) para 95 - 106% (com PI) em ICP-MS e de 5 - 123% (sem PI) para 92 -119% (com PI) em ETV-ICP-MS. Além da melhoria da exatidão o emprego do padrão interno melhorou também a precisão do... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The goal of this work was the evaluation of the bismuth as internal standard for lead determinations by the following techniques: high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS); line source flame atomic absorption spectrometry (LS FAAS); line source graphite furnace atomic absorption spectrometry (LS GFAAS); inductively coupled plasma optical emission spectrometry (ICP OES); inductively coupled plasma mass spectrometry (ICP-MS); electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS) in assorted samples. Bismuth showed efficiently correction for instrumental variations and matrix shifts. To evaluate the accuracy of developed methods three certified reference materials were analyzed and the obtained results were in agreement at 95% confidence level (t-test) with the certified values. Further addition/recovery tests showed recoveries of 74 - 231% (without IS) to 96 - 109% (with IS) in HR-CS FAAS; 52 - 118% (without IS) to 97 - 109% (with IS) in LS FAAS; 36 - 125% (without IS) to 96 - 110% (with IS) in LS GFAAS; 56 - 91% (without IS) to 95 - 110% (with IS) in ICP OES; 36 - 136% (without IS) to 95 - 106% (with IS) in ICP-MS and 5 - 123% (without IS) to 92 -119% (with IS) in ETV-ICP-MS. Further the improvement in the accuracy, the employing of internal standard improve the precision of results from 0,7 - 7,7% (without IS) to 0,1 - 4,0% (with IS) in HR-CS FAAS; 0,6 - 9,2% (without IS) to 0,3 - 4,3% (with IS) in LS FAAS; 1,5 - 9,9% (without IS) to 0,4 - 5,9% (with IS) in LS GFAAS; 0,8 - 9,0% (without IS) to 0,2 - 5,8% (with IS) in ICP OES; 0,5 - 11.3% (without IS) to 0,1 - 6,6% (with IS) in ICP-MS and 0,4 - 7,1% (without IS) to 0,1 - 4,2% (with IS) in ETV-ICP-MS. With the analytical signals obtained in the addition/recovery experiments were built up correlation graphics to... / Doutor
25

Avaliação do método de adição de padrão interno em técnicas espectroscópicas /

Fortunato, Felipe Manfroi. January 2017 (has links)
Orientador: José Anchieta Gomes Neto / Banca: Paulo Clairmont Feitosa de Lima / Banca: Mirian Cristina dos Santos / Banca: Silvana Ruella de Oliveira / Banca: Carolina Lourencetti / Resumo: O objetivo desta Tese de Doutorado foi avaliar o método de adição de padrão interno empregando técnicas espectroscópicas. Inicialmente o método de adição de padrão interno foi aplicado no modo convencional na determinação de Ca e Mg em amostras biodiesel e urina por espectrometria de absorção atômica em chama de alta resolução e fonte contínua e na determinação de ureia em urina por espectroscopia Raman. Para fins comparativos, todas as amostras e materiais certificados foram também analisados pelos métodos de calibração externa, adição de padrão e padronização interna. Nitrato, Sr e Mn foram selecionados como padrões internos para ureia, Ca e Mg, respectivamente. Para avaliar a exatidão do método na determinação de Ca e Mg foram analisados nove materiais de referência certificados (CRM) e os resultados obtidos foram concordantes a 95% de confiança com os valores certificados (teste t). Para ureia a exatidão foi avaliada por meio de comparação dos resultados obtidos pelo método de adição de padrão interno e por um método de referência. Todos os resultados obtidos foram concordantes entre si (teste t pareado) ao nível de 95% de confiança. A exatidão do método também foi checada por meio de testes de adição e recuperação: Ca (93 - 119%), Mg (100 - 116%) e ureia (99 - 105%). A desvantagem do método de adição de padrão interno convencional foi o volume total de amostra utilizado, a quantidade de soluções analíticas empregadas e a baixa frequência analítica. No entanto, este probl... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this Doctoral Thesis was to evaluation of the internal standard addition method employing spectroscopic techniques. Initially, traditional standard addition method was applied for Ca and Mg determination in biodiesel and urine samples by high-resolution continuum source flame atomic absorption spectrometry and for urea determination in urine samples by Raman spectroscopy. For comparison purposes, all samples and certified materials were also analyzed by external calibration, standard addition and internal standardization methods. Nitrate, Sr and Mn were selected as internal standards for urea, Ca and Mg, respectively. In order to verify the accuracy for Ca and Mg determination were analyzed nine certified reference materials (CRM), the results were in agreement with certified values at the 95% confidence level (t-test). For urea, the accuracy was evaluated by comparison of the results obtained by internal standard addition and a reference method. All results were in agreement at 95% confidence level (paired t-test) with each other. The accuracy was also checked by addition and recovery tests: Ca (93 - 119%), Mg (100 - 116%) and urea (99 - 105%). The drawbacks of traditional internal standard addition were the total volume of sample used, the amount of analytical solutions employed and the lower sample throughput. However, these problems were solved with the development of flow systems and the use of a concentration gradient. The internal standard addition by flow g... (Complete abstract click electronic access below) / Doutor
26

Determinação direta e simultânea de 'AL', 'AS', 'CU', 'FE', 'MN' e 'NI' em álcool etílico hidratado combustível por espectrometria de absorção atômica em forno de grafite

Oliveira, Adriana Paiva de [UNESP] 07 1900 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:09Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-07Bitstream added on 2014-06-13T19:38:10Z : No. of bitstreams: 1 oliveira_ap_me_araiq.pdf: 969605 bytes, checksum: 08894db2e370b558f0425c8e9627ff5d (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este trabalho propõe um método para a determinação direta e simultânea de Al, As, Cu, Fe, Mn e Ni em álcool etílico hidratado combustível (AEHC) por espectrometria de absorção atômica em forno de grafite (GFAAS), empregando tubo de grafite com aquecimento transversal (THGA) e corretor de fundo por efeito Zeeman longitudinal. Foram avaliados dois tipos de modificadores: a mistura nitrato de paládio + nitrato de magnésio, e o modificador permanente W/Rh. No primeiro caso, as curvas analíticas foram obtidas injetando-se 10 mL das soluções de referência (2,0, 5,0, 10, 20, 30, 40 e 50 mg L-1 Al, As, Cu, Fe, Mn e Ni em meio 0,28 mol L-1 HNO3 ) + 10 mL de etanol P.A. + 5 mL Pd(NO3)2+ 3 mL Mg(NO3)2. Para determinar os analitos, foram injetados 10 mL de amostra + 10 mL de solução 0,28 mol L-1 HNO3 + 5 mL Pd(NO3)2 + 3 mL Mg(NO3)2. No teste de adição e recuperação, foram injetados 10 mL de amostra + 10 mL de solução 60 mg L-1 Al, As, Cu, Fe, Mn e Ni em meio 0,28 mol L-1 HNO3+ 5 mL Pd(NO3)2 + 3 mL Mg(NO3)2. Todas as medidas foram feitas em absorbância integrada e em triplicata. O programa de aquecimento otimizado (temperatura, tempo de rampa, tempo de patamar) foi o seguinte: secagem 1 (120oC, 1 s, 10 s); secagem 2 (150oC, 5 s, 25 s); pirólise (1200oC, 10 s, 20 s); atomização (2200oC, 1 s, 6 s) e limpeza (2550oC, 1 s, 3 s). As massas características foram 37 pg Al, 73 pg As, 31 pg Cu, 16 pg Fe, 9 pg Mn e 44 pg Ni e o tempo de vida do atomizador foi equivalente a aproximadamente 250 ciclos de aquecimento. Os desvios padrões relativos (n=12) foram £3%, £6%, £2%, £3,4%, £1,3% e £2% para Al, As, Cu, Fe, Mn e Ni, respectivamente. As recuperações dos analitos adicionados às amostras coletadas em postos de abastecimento da cidade de Araraquara variaram entre 77-112%, 92-114%, 104-113%, 91-116%, 91-122% e 93-116% para Al, As, Cu, Fe, Mn e Ni, respectivamente... / This work describes a method for direct and simultaneous determination of Al, As, Cu, Fe, Mn and Ni in fuel ethanol by electrothermal atomic absorption spectrometry (GFAAS) with transversely heated graphite atomizer (THGA) and longitudinal Zeeman-effect background corrector. The following modifiers were evaluated: a) the mixture Pd(NO3)2 + 3 æL Mg(NO3)2; b) W/Rh as permanent modifier. Regards to Pd/Mg(NO3)2, analytical curves were obtained by injecting 10 æL of each analytical solutions (2.0, 5.0, 10, 20, 30, 40 and 50 æg L-1 Al, As, Cu, Fe, Mn, Ni in 0.28 mol L-1 HNO3) plus 10 æL of ethanol P.A. plus 5 æL Pd(NO3)2 plus 3 æL Mg(NO3)2. For determination, 10 æL of samples plus 10 æL of 0.28 mol L-1 nitric acid solution plus 5 æL Pd(NO3)2 + 3 æL Mg(NO3)2 were sequentially injected. For analyte addition tests, 10 æL sample plus 10 æL of 60 æg L-1 Al, As, Cu, Fe, Mn e Ni containing 0.28 mol L-1 HNO3 plus 5 æL Pd(NO3)2 plus 3 æL Mg(NO3)2 were sequentially injected. All measurements were carried out in triplicate and integrated absorbance. The optimized heating program of graphite tube (temperature, ramp time, hold time) was: dry 1 (120oC, 1 s, 10 s); dry 2 (150oC, 5 s, 25 s); pirolysis (1200oC, 10 s, 20 s); atomization (2200oC, 1 s, 6 s) and clean (2550oC, 1 s, 3 s). The characteristic masses were calculated as 37 pg Al, 73 pg As, 31 pg Cu, 16 pg Fe, 9 pg Mn and 44 pg Ni. The lifetime of atomizer was equivalent to ca. 250 heating cycles. Relative standard deviations (n=12) were =3%, =6%, =2%, =3.4%, =1.3% and =2% for Al, As, Cu, Fe, Mn and Ni, respectively. The recoveries of Al, As, Cu, Fe, Mn and Ni added to fuel ethanol samples varied from 77 to 112%, 92 to 114%, 104 to 113%, 91 to 116%, 91 to 122% and 93 to 116%, respectively. Accuracy was checked for Al, As, Cu, Fe, Mn and Ni determination in 20 samples purchased at a local gas stations in Araraquara city, Brazil... (Complete abstract, access undermentioned electronic address)
27

Distribuição da intensidade no espectro vibracional de moléculas diatômicas : comparação teórica e experimental nos sistemas N2(2+) e N2(1-)

Gallas, Jason Alfredo Carlson January 1978 (has links)
Este trabalho consiste num estudo de espectroscopia de moléculas diatômicas. / Spectroscopic properties of diatomic molecules are investigated.
28

Desenvolvimento de métodos analíticos para determinação de elementos traço em materiais poliméricos utilizando amostragem sólida por espectrometria de absorção atômica em forno de grafite

Duarte, Álvaro Tavares January 2010 (has links)
A União Europeia ao adotar as diretivas: 2002/96/EC — WEEE e a 2002/95/EC — RoHS de modo a minimizar os resíduos equipamentos eletroeletrônicos (WEEE — do inglês: Waste Eletrical Electronic Equipment) e restringir as substancias nocivas (RoHS — do inglês: Restriction of Hazardous Substances) vem causando um grande impacto na rotina de controle de substancias perigosas, incluindo metais taco tóxicos, como chumbo, cadmio e cromo, em todos os materiais que são utilizados nesses equipamentos. Os componentes plásticos são os principais constituintes dos equipamentos eletrônicos e uma potencial fonte de metais taco tóxicos que são adicionados como estabilizantes, corantes e catalisadores. Como esses materiais plásticos são desenvolvidos de modo a serem resistentes a ataques químicos, eles são normalmente difíceis de serem dissolvidos. Sob esta motivação, neste trabalho foram desenvolvidos e otimizados métodos para a determinação de cadmio, chumbo e cromo utilizando a técnica de amostragem direta de sólidos por espectrometria de absorção atômica com forno de grafite. Em todos os procedimentos o foco principal foi a redução de tratamento das amostras, bem como o emprego de soluções padrão aquosas a fim de tornar os métodos mais simples e facilmente aplicáveis a rotina. O use de modificador químico, mistura de paládio e magnésia foi mandatório para estabilizar cadmio e chumbo. As determinações de cromo foram realizadas sem a adição de modificador químico. Calibração versus padrões aquosos Ode ser utilizada para a determinação dos três analitos. Nas determinações de chumbo e de cromo de modo a ter uma maior faixa linear de concentração usou-se o artificio de trabalhar com ou sem fluxo de gás na etapa de atomização. No caso da determinação de cadmio linhas analíticas (228,8 nm e 326,1 nm) com diferentes sensibilidades foram empregadas para ampliar a faixa linear do método. Os limites de detecção foram: 0,7 lig kg-1, 22 prg kg1 e 13 jig kg-1 para cadmio, chumbo e cromo, respectivamente. Materiais de referencia certificados foram utilizados para a validação dos métodos, não havendo diferença significativa entre os valores obtidos e os certificados. Oito amostras de resíduos de equipamentos eletroeletrônicos foram analisadas, estando todas em conformidade com as diretivas WEEE e RoHS. / By adopting the directives 2002/96/EC — WEEE (Waste Eletrical and Electronic Equipment) and 2002/95/EC — RoHS (Restriction of Hazardous Substances) the European Union will cause a great impact on the routine control of hazardous substances, including toxic trace metals, such as lead, cadmium and chromium, in all the materials that are used in this kind of equipment. Plastic components are among the main constituents of electronic equipment and a potential source of toxic trace metals, which are added as stabilizers, catalysts and/or colorant. As these plastic materials are designed to be resistant against chemical attack, they are usually very difficult to bring into solution. Because of that, methods have been developed and optimized in this work for the determination of cadmium, lead and chromium using direct solid sampling graphite furnace atomic absorption spectrometry. The primary aspects in all all method development have been reduction of sample treatment and the use of aqueous Standards for calibration in order to make methods simple and easily applicable in routine. The use of a mixture of palladium and magnesium as a chemical modifier was found to be mandatory for the determination of cadmium and lead, whereas no modifier was necessary for the determination of chromium. Calibration against aqueous standards could be used for all three analytes. In order to increase the linear working range for the determination of chromium and lead, the determination has been carried out with the internal gas flow turned off and on, respectively, during atomization. In the case of cadmium, the analytical lines at 228.8 nm and 326.1 nm, respectively, with significantly different sensitivities were used for that purpose. The detection limits were 0.7 p.g kg', 22 pig kg-1 and 13 !,ig kg-1 for cadmium, lead and chromium, respectively. Certified reference materials were used for validation of the methods, and there was no significant difference between the found and the certified values. Eight samples of residues of electronic equipment have been analyzed, and all of them were within the limits of the directives of WEEE and RoHS.
29

Estratégias de análise direta de amostras para determinação de elementos traço em biomassa e seus produtos de pirólise por espectrometria de absorção atômica de alta resolução com fonte contínua e forno de grafite

Duarte, Álvaro Tavares January 2014 (has links)
No presente trabalho foi investigada a viabilidade da aplicação da técnica de análise direta (com mínimo preparo de amostra) por espectrometria de absorção atômica de alta resolução com fonte continua e fomo de grafite (DS-HR-CS GF AAS). Métodos foram desenvolvidos para a determinação de chumbo, cádmio e cromo em amostras de biomassa, bio-óleo, água de pirólise e cinzas de biomassa (obtidos através de processo de pirólise ). As determinações foram realizadas sem adição de modificador quimico e utilizando calibração com soluções padrão aquosas. A determinação de cádmio e cromo foi realizada de maneira sequencial, ou seja, feita somente uma pesagem de amostra para determinação dos dois elementos, que possibilita trabalhar com uma menor quantidade de amostra e aumenta a velocidade analítica do método. Os métodos desenvolvidos se mostraram sensíveis, exatos, precisos e aplicáveis à rotina, com exceção do método desenvolvido para determinação sequencial de cádmio e cromo em amostras de bio-óleo, que apresentou limitações para determinação de cádmio. Após a determinação desses metais nas amostras analisadas, foi realizado um balanço de massas e estimado que a maior parte de chumbo e cromo presente na biomassa é eliminada para o ambiente durante o processo de pirólise, ficando uma parte significante retida nas cinzas. / In this work was investigated the feasibility of applying the technique of direct analysis (with a minimum sample preparation) by High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry (HR-CS DS-GF AAS). Methods have been developed for the determination o f lead, cadmium and chromium in biomass, bio-oil, the aqueous phase o f the pyrolysis, and biomass ashes ( obtained by the pyrolysis process ). Ali measurements were performed without chemical modifier and using aqueous standard solutions for calibration. The determination of cadmium and chromium was performed in a sequential mode, determining both elements from the same sample aliquot, which allows work:ing with a small quantity of sample and increases the speed of the analytical method. The developed methods were sensitive, accurate and applicable to routine, with the exception of the method for sequential determination of cadmium and chromium in bio-oil, which presented lirnitations for the determination of cadmium. After determination ofthese metais in the samples, a mass balance was performed and estimated that most of the lead and chromium present in the biomass were emitted to the environment during the pyrolysis process, with a significant portion retained in the ashes.
30

DinÃmica molecular e cÃlculos ab initio em molÃculas, nanocones de carbono e agregados de Ãgua.

Marcelo da Silva Pires 17 July 2009 (has links)
Conselho Nacional de Desenvolvimento CientÃfico e TecnolÃgico / A presente dissertaÃÃo insere-se no escopo da NanociÃncia e da Nanotecnologia, que tÃm como objeto de estudo sÃo sistemas (nanoestruturas, nanopartÃculas, nanoagregados, etc.) com dimensÃes caracterÃsticas no intervalo 1{100 nm (1nm = 10ÂA). Nela sao investigadas: (a) propriedades estruturais de nanocestas moleculares de carbono e sua interaÃÃo com o aminoÃcido L-alanina; (b) a interaÃÃo entre nanocones de carbono anin- hados; e (c) a transiÃÃo estrutural dependente da temperatura de agregados de Ãgua. Os nanosistemas foram estudados atravÃs de DinÃmica Molecular, que permite o estudo de sistemas com cerca atà milhÃes de Ãtomos, e da Teoria do Funcional da Densidade, que permite a obtenÃÃo das propriedades do estado fundamental de sistemas com atà centenas de Âatomos. No estudo das nanocestas de carbono C20-coranuleno, C30-hemifulereno, C35- hemifulereno e C36-triacenaftotrifenileno, obteve-se que as mesmas s~ao estÂaveis a temper- aturas elevadas, e demonstrou-se a capacidade das mesmas de servirem como armadilhas para o aminoÂacido L-alanina, como efeito da mistura dos orbitais  e  nestas estruturas produzida pela curvatura. Nanocones de carbono s~ao estruturas c^onicas de carbono ob- servadas durante o processo de sÂÂntese de nanotubos de carbono, existindo com ^angulos de abertura 19:2 Â, 38:9 Â, 60:0 Â, 83:6 Â, e 112:9 Â. Experimentalmente estes nanocones encontram-se, em geral, aninhados. Para pares de nanocones de carbono aninhados, obteve-se a depend^encia do potencial de interaÂc~ao entre os mesmos com o ^angulo ddas pontas e o nÂumero de Âatomos de carbono. Finalmente, obteve-se que a interaÂc~ao entre molÂeculas de Âagua atravÂes de ligaÂc~oes de hidrog^enio dÂa origem a agregados estÃveis de Ãgua: dÃmeros , trÃmeros, tetrÃmeros, pentÃmeros, hexÃmeros, etc. quando formados por duas, trÃs, quatro, cinco e seis molÃculas de Ãgua, respectivamente. Para estes agregados, foi obtido o potencial de interaÃÃo entre duas camadas empilhadas, e demonstrou-se uma surpreendente transiÃÃo de fase de dois trÃmeros empilhados para um hexÃmero, de quatro trÃmeros empilhados para dois hexÃmeros, e tambÃm de trÃs tetrÃmeros empilhados para dois hexÃmeros. As pesquisas realizadas enquadram-se na temÃtica de atuaÃÃo do In- stituto de NanoBioEstruturas & SimulaÃÃo NanoBioMolecular [NANO(BIO)SIMES], um dos Institutos Nacionais de CiÃncia e Tecnologia financiados pelo CNPq a partir do inÃcio de 2009, que visa desenvolver atividades de pesquisa e formaÃÃo de recursos humanos de alto nÃvel em nanobioestruturas e simulaÃÃo nanobiomolecular.

Page generated in 0.0379 seconds