• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 107
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 110
  • 38
  • 38
  • 35
  • 35
  • 34
  • 32
  • 29
  • 25
  • 25
  • 24
  • 23
  • 14
  • 14
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Caracterização do material particulado inalavel (MP10) na atmosfera de Paulinia e região

Fidelis, Carlos Henrique de Vasconcelos 03 August 2018 (has links)
Orientador: Wilson de Figueiredo Jardim / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-03T16:13:22Z (GMT). No. of bitstreams: 1 Fidelis_CarlosHenriquedeVasconcelos_M.pdf: 5748636 bytes, checksum: f1bb82d25e16ee9e8de093bbecb41629 (MD5) Previous issue date: 2003 / Mestrado
32

Cargas atomicas (um novo modelo) : implementação computacional e aplicações

Souza, Alexandre Araújo de 20 July 2018 (has links)
Orientador: Marcia Miguel Castro Ferreira / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-20T16:59:35Z (GMT). No. of bitstreams: 1 Souza_AlexandreAraujode_M.pdf: 5528376 bytes, checksum: 9abf71d84d25f07c897f751ce2627724 (MD5) Previous issue date: 1994 / Mestrado
33

[en] ANALYTICAL METHODS FOR THE DETERMINATION OF MERCURY SPECIES USING COLD VAPOUR BASED SPECTROMETRY: APPLICATION IN CHALLENGING SAMPLES AND USE OF NANOPARTICLES AS PHOTOCATALYTIC AGENTS / [pt] MÉTODOS ANALÍTICOS PARA A DETERMINAÇÃO DE ESPÉCIES DE MERCÚRIO UTILIZANDO ESPECTROMETRIA BASEADA NA GERAÇÃO DE VAPOR FRIO: APLICAÇÃO EM AMOSTRAS COMPLEXAS E UTILIZANDO NANOPARTÍCULAS COMO AGENTES FOTOCATALÍTICOS

JAROL RAMON MIRANDA ANDRADES 08 May 2020 (has links)
[pt] O objetivo do trabalho foi desenvolver métodos analíticos capazes de especiar mercúrio, determinando metilmercúrio (CH3Hg), etilmercúrio (CH3CH2Hg), mercúrio inorgânico (Hg2+, Hg0), em água de produção (AP), e tiomersal (C9H9HgNaO2S), em urina e em efluente de uma indústria farmacêutica. Apesar de existir muitos métodos para quantificar espécies de mercúrio, poucos estudos abordam a especiação em AP, amostras conhecidas por ter altos teores de óleo e sal. Além disso, o uso de nanomateriais, como pontos quânticos de grafeno (GQDs), sozinho ou dopados de nanopartículas de dióxido de titânio (GQDs-TiO2 NPs), foram usados como agentes fotocatalíticos para produzir o mercúrio elementar detectado. As técnicas analíticas utilizadas para a detecção de mercúrio total e para especiação por mercúrio foram espectrometria de absorção atômica com vapor frio em cela multipasso (multipath-CV-AAS) e espectrometria de fluorescência atômica com vapor frio acoplado ao sistema de cromatografia gasosa (GC-CV-AFS). No primeiro trabalho, a foto-degradação do tiomerosal foi alcançada utilizando luz visível e GQDs, obtidos a partir da hidroexfoliação de ácido cítrico e glutationa, como foto-catalisador. O Hg0 gerado (usando condições experimentais ajustadas) foi detectado por multipath-CV-AAS, permitindo a quantificação de tiomersal em concentrações equivalentes a 20 ng L-1, mesmo em amostras complexas como efluentes aquosos da indústria farmacêutica e em urina. A cinética de reação (pseudo-primeira ordem com k = 0,11 min-1) foi determinada. O segundo trabalho relata o método de especiação de mercúrio em AP usando o sistema CV-AAS. Sob condições ajustadas de concentrações de sal e óleo (por diluição e centrifugação), uma alíquota de amostra foi tratada com SnCl2, levando ao Hg0 quantificado como mercúrio inorgânico original. Uma segunda alíquota de amostra foi exposta a UV (sob condições otimizadas) que promoveu a oxidação de CH3Hg a Hg2+, formando Hg2+ que foi posteriormente reduzido, com SnCl2, produzindo o Hg0 referente ao teor total de mercúrio na amostra. O teor de CH3Hg foi obtido pela diferença nos resultados alcançados para as duas alíquotas. O efeito matriz imposto por óleo e sal foram estudados e, apesar de afetar a intensidade do perfil do tempo de mercúrio, a quantificação foi alcançada com sucesso com padrões ajustados (assemelhamento de matriz) combinando quantidades de NaCl e óleo mineral. As medições de condutividade (estimativa de teor de sal) e turbidimétrica (estimativa de teor de óleo) foram feitas para as amostras de PW, a fim de permitir o ajuste adequado da amostra aos padrões correspondentes (contendo óleo mineral a 5 mg L-1 e NaCl a 5 g L-1). O método de adição de analito também foi utilizada e o limite de quantificação foi de 12 ng L-1. / [en] The aim of the present work was to develop analytical methods capable of determining mercury species such as methylmercury (CH3Hg), ethylmercury (CH3CH2Hg), inorganic mercury (Hg2+, Hg0), in produced water (PW) and urine, as well as thiomersal C9H9HgNaO2S) in effluent from a pharmaceutical industry and in urine. Despite many methods for quantifying mercury species are reported, few studies address speciation in PW, sample known to have high oil and salt contents. Besides, the use of nanomaterials such as graphene quantum dots (GQDs) alone or decorating titanium dioxide nanoparticles (GQDs-TiO2 NPs) were used as photocatalytic agents to produce the detected elemental mercury. The analytical techniques used for total mercury detection and mercury speciation were multipath cold vapor atomic absorption spectrometry (multipath˗CV˗AAS) and gas chromatography cold vapor atomic fluorescence spectrometry (GC˗CV˗AFS). In the first work, the photo-degradation of thiomersal has been achieved using visible light and GQDs, obtained from hydro-exfoliation of citric acid and glutathione, as catalysts. The generated Hg0 (using adjusted experimental conditions) was detected by multipath-CV-AAS, enabling quantification of thiomersal at values as low as 20 ng L-1 even in complex samples as aqueous effluents from the pharmaceutical industry and in the urine. The reaction kinetic (pseudo-first-order with k = 0.11 min-1 ) was determined. The second work provided a speciation method for mercury in PW using multipath-CV-AAS. Under adjusted salt and oil contents (by dilution and centrifuging), a sample aliquot was treated with SnCl2, leading to the Hg0 quantified as the original inorganic mercury. A second sample aliquot was exposed to UV (under optimized conditions) that promoted oxidation of CH3Hg to Hg2+, which was then reduced, with SnCl2, producing the Hg0 relative to the total mercury content in the sample. The CH3Hg content was obtained by the difference in results achieved for both aliquots. Matrix effects imposed by oil and salt were studied, and although affecting the intensity of the mercury time profile, quantification was successfully achieved by matrix-matched standards containing NaCl and mineral oil.
34

[en] SEMICONDUCTOR NANOSTRUCTURE FABRICATION IN MECHANICAL DEFECTS PRODUCED BY ATOMIC FORCE MICROSCOPY / [pt] FABRICAÇÃO DE NANOESTRUTURAS SEMICONDUTORAS EM DEFEITOS PRODUZIDOS POR MICROSCOPIA DE FORÇA ATÔMICA

HENRIQUE DUARTE DA FONSECA FILHO 23 January 2009 (has links)
[pt] A combinação de alta densidade, locais seletivos de nucleação e controle da distribuição de tamanho de nanoestruturas semicondutoras tem acelerado o desenvolvimento de dispositivos ópticos e eletrônicos. Para construir estruturas satisfazendo essas necessidades, várias combinações de técnicas deposição de pontos quânticos e nanolitografia foram desenvolvidas. A nanolitografia por AFM foi aplicada em diversos materiais abrindo uma possibilidade para fabricar dispositivos opto-eletrônicos.Nesta tese de Doutorado, apresentamos um estudo sistemático de crescimento de nanoestruturas de InAs em buracos produzidos na superfície (100) de substratos de InP por nanoindentação com o AFM. Para isto, a ponta precisa exercer uma força no InP que produz deformações plásticas na superfície. A pressão aplicada entre a extremidade da ponta de AFM e a superfície da amostra pode ser variada de modo controlado através do ajuste de alguns parâmetros operacionais do microscópio tais como setpoint, raio da ponta e constante de mola do cantilever. A habilidade para controlar a forma do padrão indentado assim como a natureza dos defeitos cristalinos permite controlar o crescimento seletivo de InAs por epitaxia em fase de vapor de metais orgânicos. Também é apresentada a fabricação de nanoestruturas de InAs/InP alinhadas em uma dimensão. A nanoindentação é produzida pelo arraste da ponta do AFM sob força constante ao longo das direções <100> e <110> do InP. Observamos que o número e o tamanho das nanoestruturas nucleadas são dependentes da distância entre as linhas litografadas. Esses resultados sugerem que o mecanismo de crescimento das nanoestruturas de InAs não é governado por degraus atômicos gerados durante a indentação. Os dados sugerem que, a densidade de defeitos induzidos mecanicamente, tais como discordâncias e fraturas, é o responsável pelo número de nanoestruturas nucleadas. / [en] The combination of high density, site selective nucleation, and size distribution control of semiconductor nanostructures has become a challenge in the development of effective optical and electronic devices. In order to build structures satisfying these requirements, various combinations of quantum dot deposition and nanolithography techniques have been developed. The AFM nanolithography technique has been applied on several materials opening a possibility to fabricate opto-electronic devices. In this Phd Thesis, we present a systematic study of growth of InAs nanostructures on pits produced on (100) InP by nanoindentation with the AFM. For that purpose, the AFM tip needs to exert a force on the InP that produces plastic deformation on the surface. The applied pressure between the very end of the AFM tip and the sample surface may be varied in a controlled way by adjusting some of the microscope operational parameters like set point, tip radius and cantilever normal bending constant. The ability to control the shape of the indentation pattern as well as the nature of the crystalline defects allows control of the selective growth of InAs by metal organic vapor phase epitaxy. We also report the fabrication of one-dimensional arrays of InAs/InP nanostructures. The nanoindentation is produced by dragging the AFM tip under constant force of the substrate, along the <100> and <110> InP crystallographic directions. We have observed that the number and the size of nucleated nanostructures are dependent on the distance between the lithographed lines. These results suggest that the growth mechanism of the InAs nanostructures on the pits produced by AFM on InP is not governed by the number of atomic steps generated during the scratching. Instead, the data suggests that, the density of mechanically induced defects, like dislocations and cracks, are responsible for the number of nucleated nanostructures.
35

"Avaliação da concentração de metais em amostras de sedimentos do Reservatório Billings, Braço Rio Grande, São Paulo, Brasil" / Assessment of metal concentrations in sediment samples from Billings reservoir, Rio Grande tributary, São Paulo, Brazil

Bostelmann, Eleine 22 June 2006 (has links)
O presente estudo consistiu em caracterizar quimicamente amostras de sedimentos da represa Billings, braço Rio Grande, na região Metropolitana de São Paulo, por meio da determinação da concentração de metais e outros elementos de interesse. Os parâmetros químicos escolhidos para esta caracterização, foram as concentrações de Alumínio, Arsênio, Bário, Cádmio, Chumbo, Cobre, Cromo, Ferro, Manganês, Mercúrio, Níquel, Selênio e Zinco. Esses parâmetros são também utilizados na determinação do Índice de Qualidade das Águas (com exceção do Selênio). As determinações foram efetuadas pelas técnicas analíticas de espectrometria de absorção atômica (FAAS, GFAAS e CVAAS), espectrometria de emissão ótica (ICP OES) e análise por ativação neutrônica (AAN). Essas metodologias analíticas foram avaliadas quanto à precisão, exatidão e limite de detecção e/ou quantificação para os elementos determinados, nas amostras de sedimentos. Foram discutidas também as vantagens e desvantagens de cada técnica utilizada, para cada elemento, dependendo de sua concentração. A partir dessa análise, selecionou-se a técnica mais apropriada para a determinação de cada elemento, para a implementação em análise de rotina de amostras de sedimentos. Dessa forma verificou-se que a digestão efetuada assistida por microondas em sistema fechado com ácido nítrico é eficiente para a quantificação da concentração de metais extraíveis de interesse ambiental. Verificou-se também que as técnicas escolhidas para as determinações dos metais eram igualmente eficientes. No caso dos metais Cd e Pb, com a técnica de FAAS obteve-se resultados melhores do que a técnica de ICP OES, por não apresentar interferência de matriz. Os valores de concentração para os metais As, Cd, Cu, Cr, Hg, Ni, Pb e Zn nas amostras de sedimentos foram comparados com os valores orientadores (TEL e PEL) do Canadian Council of Minister of the Environment (CCME). Esse projeto definiu as técnicas analíticas e parâmetros, para um melhor monitoramento dos níveis de contaminação de sedimentos por metais, fornecendo dados que possam ser utilizados para direcionar atitudes e manejos de sistemas aquáticos. / The present study chemically characterized sediment samples from the Billings reservoir, Rio Grande tributary, in the Metropolitan region of São Paulo, by determining metal concentration and other elements of interest. The chosen chemical parameters for this characterization were Aluminum, Arsenic, Barium, Cadmium, Copper, Chromium, Iron, Lead, Manganese, Mercury, Nickel, Selenium and Zinc. These parameters are also used in the water quality index, with the exception of Selenium. The concentrations were determined through different analytical techniques such as atomic absorption spectrometry (FAAS, GFAAS and CVAAS), optical emission spectrometry (ICP OES) and neutron activation analysis. These analytical methodologies were assessed for precision, accuracy and detection and/or quantification limits for the sediment elements in question. Advantages and disadvantages of each technique for each element and its concentration were also discussed. From these assessment the most adequate technique was selected for the routine analysis of sediment samples for each element concentration determination. This assessment verified also that digestion in a closed microwave system with nitric acid is efficient for the evaluation of extracted metals of environmental interest. The analytical techniques chosen were equally efficient for metals determination. In the case of Cd and Pb, the FAAS technique was selected due to better results than ICP OES, as it does not present matrix interference. The concentration values obtained for metals As, Cd, Cu, Cr, Hg, Ni, Pb and Zn in the sediment samples were compared to Canadian Council of Minister of the Environment (CCME) TEL and PEL values.
36

Desenvolvimento de métodos para a determinação de Pb, Cd, Cr, Ni e Sb em cosméticos faciais por espectrometria de absorção atômica em forno de grafite de alta resolução com fonte contínua empregando amostragem direta de sólidos /

Barros, Ariane Isis. January 2016 (has links)
Orientador: José Anchieta Gomes Neto / Coorientador: Edilene Cristina Ferreira / Banca: Paulo Clairmont Feitosa de Lima Gomes / Banca: Clóvis Augusto Ribeiro / Banca: Joaquim de Araujo Nóbrega / Banca: Cassiana Seimi Nomura / Resumo: Este trabalho relata o desenvolvimento de métodos para a determinação de Pb, Cd, Cr, Ni e Sb em cosméticos faciais por espectrometria de absorção atômica em forno de grafite de alta resolução com fonte contínua (HR-CS GF AAS) empregando análise direta de amostras sólidas. Essa técnica foi utilizada devido a sua alta capacidade para a correção de fundo baseada em algoritmos dos mínimos quadrados. Para a determinação de Pb e Sb, interferências causadas por moléculas de SiO(g) nas linhas 283,306 nm (Pb), 217,582 nm (Sb) e 231,147 nm (Sb) foram eliminadas pela aplicação do método de correção de fundo pelos mínimos quadrados (LSBC). Para a correção de fundo na determinação de Pb, o espectro de referência foi gerado a partir de SiO2. Diferentes precursores foram avaliados para geração do espectro de referência para a correção de fundo na determinação de Sb, sendo a zeólita e a mica os precursores mais eficazes. Efeitos de matriz foram avaliados pela comparação das massas características e inclinações das curvas obtidas em padrões aquosos e amostras (ou material de referência certificado). Calibrações com padrões aquosos foram possíveis e curvas com bom coeficiente de correlação (r>0,99) foram obtidas para todos os analitos. Os limites de detecção foram de 0,06 mg kg -1 Pb, 3,67 µg kg-1 Cd, 0,5 mg kg-1 Cr, 0,292 mg kg-1 Ni e 0,32 mg kg-1 Sb. As concentrações dos analitos encontradas em amostras comerciais de blush, sombra de olho e pó compacto variaram de 1,0 - 27,08 mg kg-1 Pb, 5,0... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This work reports on the development of methods for determination of Pb, Cd, Cr, Ni and Sb in facial cosmetics by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS) employing direct solid sample analysis. This technique was used due to the high capability for background correction based on least-squares algorithm. For Pb and Sb determinations, interferences caused by SiO(g) molecule at the lines 283.306 nm (Pb), 217.582 nm (Sb) and 231.147 nm (Sb) were eliminated by applying the least-squares background correction (LSBC). For background correction in the determination of Pb, a reference spectrum was generated from SiO2. Different precursors were evaluated to generate reference spectra for correction of the background in the determination of Sb, been zeolite and mica the most effective precursors. Matrix effects were evaluated by comparing the characteristics masses and slopes of curves in aqueous standards and sample (or certified reference material). Calibration with aqueous standards were possible, and curves with good correlation coefficients (r>0.99) were attained for all analytes. The limits of detection were 0.06 mg kg-1 Pb, 3.67 µg kg-1 Cd, 0.5 mg kg-1 Cr, 0.292 mg kg-1 Ni and 0.32 mg kg-1 Sb. The found concentrations of analytes in commercial blush, eye shadow and compact powder samples were within 1.0 - 27.08 mg kg-1 Pb, 5.06 - 198.20 µg kg-1 Cd, 2.87 - 23.65 mg kg-1 Cr, 1.36 - 12.09 mg kg-1 Ni, and 9.14 - 14.52 mg kg-1 Sb... (Complete abstract click electronic access below) / Doutor
37

Determinação de Co, Mo, Ni e V em material vegetal e solo por espectrometria de absorção atômica com fonte contínua e de alta resolução em forno de grafite empregando amostragem direta de sólidos /

Babos, Diego Victor de. January 2016 (has links)
Orientador: José Anchieta Gomes Neto / Banca: Clovis Augusto Ribeiro / Banca: Pedro Henrique de Cerqueira Luz / Resumo: Avaliou-se a amostragem direta de sólidos como base de métodos analíticos simples, rápidos e mais limpos para determinar Co, Mo, Ni e V em tecido vegetal e solo empregando a espectrometria de absorção atômica de alta resolução com fonte contínua. Esta técnica foi escolhida devido as suas características peculiares, especialmente a elevada capacidade de correção de fundo. Na determinação de cobalto em material vegetal, a sobreposição espectral de SiO(g) na linha 240,725 nm do Co foi corrigida pelo método dos mínimos quadrados. Curvas de calibração (0-540 pg) com bons coeficientes de correlação lineares (R 0,9993) foram obtidas com padrões sólidos. O limite de detecção (LOD) foi 3 pg Co. Na determinação simultânea de Mo e Ni em material vegetal, empregou-se Co como padrão interno para Ni. Curvas de calibração (0,8-50 ng Ni; 0-0,33 ng Mo) lineares (R 0,9937) foram obtidas com padrões aquosos sem modificador químico. Os LODs foram 0,018 ng Mo e 0,025 ng Ni. A padronização interna aumentou a precisão das medidas para Ni de 62-135% para 94-105%. Vanádio e Co foram determinados em solos empregando NH4F como modificador. As calibrações, com padrões aquosos para V (0-40 ng), e por compatibilização de matriz para Co (0-5,0 ng), forneceram R 0,9979. Os LODs foram 0,044 ng Co e 0,43 ng V. Na determinação de Mo e Ni em solo, o modificador Mg(NO3)2 foi utilizado apenas para Ni. As curvas de calibração aquosas (0-500 ng Ni; 0-0,54 ng Mo) forneceram R 0,9953. Na determinação do Ni foi mo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: High-resolution continuum source atomic absorption spectrometry with direct solid sampling was employed for the development of simple, fast and clean analytical methods for Co, Mo, Ni and V determination in soil and plant materials. The technique has as main advantages the efficiency to correct background absorption. For cobalt determination in plant material, a spectral overlap of SiO molecular absorption in Co line was corrected by using least squares background correction method. Calibration curves (0-540 pg) with correlation coefficients higher of 0.9993 were obtained with solid standards. The limit of detection was of 3 pg Co. For simultaneous determination of Mo and Ni in plant material Co was employed as internal standard for Ni. Calibration curves (0.8-50 ng Ni; 0-0.33 ng Mo) with correlation coefficients higher of 0.9937 were obtained with aqueous standards without chemical modifier. The LODs were 0.025 and 0.018 ng for Mo and Ni, respectively. The internal standardization increased the accuracy of Ni determinations from 62-135% to 94-105%. For V and Co determinations in soils the NH4F was used as chemical modifier. The calibration with aqueous standards for V (0-40 ng), and compatibility matrix for Co (0-5.0 ng), provided linear correlation coefficients better of 0.9979. The LODs were 0.044 and 0.43 ng for Co and V, respectively. For Mo and Ni determination in soil the Mg(NO3)2 was used as chemical modifier for Ni. The aqueous calibration curves (0-500 ng Ni; 0-0.54... (Complete abstract click electronic access below) / Mestre
38

Filmes nanoestruturados de fosfolipídios como sistemas miméticos de membrana biológica para aplicação em sensores via sers e espectroscopia de impedância /

Aoki, Pedro Henrique Benites. January 2011 (has links)
Orientador: Carlos José Leopoldo Constantino / Banca: Luis Vicente de Andrade Scalvi / Banca: Eloi da Silva Feitosa / Banca: Paola Corio / O programa de Pós graduação em Ciência e Tecnologia de Materiais, POSMAT, tem carater institucional e integra as atividades de pesquisa em materiais de diversos campi da UNESP / Resumo: A presente dissertação de mestrado trata da fabricação de filmes ultrafinos (nanômetros de espessura) de fosfolipídios aniônicos (DPPG e CLP) e zwiteriônicos (DPPC e DOPC) utilizando as técnicas layer-by-layer (LbL) e Langmuir-Blodgett (LB), possibilitando assim a obtenção de filmes com diferentes arquiteturas moleculares. O objetivo principal foi explorar a aplicação destas diferentes arquiteturas moleculares na detecção do fármaco fenotiazínico azul de metileno (AM) em soluções diluídas. O crescimento linear, camada por camada, desses filmes foi verificado e monitorado por espectroscopia de absorção no UV-Vis. Verificou-se por FTIR que o crescimento dos filmes LbL e LB é determinado por interações eletrostáticas entre os fosfolipídios e o polieletrólito catiônico PAH utilizado como camada de suporte, favorecendo o crescimento dos filmes com fosfolipídios aniônicos. A morfologia foi analisada através de microscopias ópticas, AFM e MEV, revelando que os fosfolipídios estruturam-se como vesículas nos filmes LbL e monocamadas nos filmes LB. Filmes LbL e LB de fosfolipídios com diferentes espessuras foram então depositados sobre eletrodos interdigitados de Pt formando unidades sensoriais que foram aplicadas na detecção de AM via espectroscopia de impedância. Os resultados mostraram que as diferentes arquiteturas moleculares dos filmes LbL e LB levam a respostas elétricas distintas e permitem a detecção de AM em concentrações de nanomolar. A técnica SERS foi utilizada para obter informações estruturais do sistema AM/fosfolipídios nos níveis de diluição alcançados via espectroscopia de impedância. Para tanto, monocamadas LB foram depositados sobre filmes evaporados com 6 nm de Ag e nanopartículas de Ag foram dispersas no interior dos filmes LbL. A presença da Ag na forma de nanopartículas em ambos os casos permitiu a obtenção... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Thin films of anionic (DPPG and CLP) and zwiterionic (DPPC and DOPC) phospholipids with different molecular architectures were fabricated using the layer-by-layer (LbL) and Langmuir-Blodgett (LB) techniques. The main goal of this work was to explore the Application of these distinct molecular architectures in the detection of high diluted solutions of methylene blue (MB), a phenothiazine derivative drug. The linear growth, layer by layer, of these films was verified and monitored by UV-Vis absorption spectroscopy. It was found by FTIR that electrostatic interactions among the phosholipids and the supporting layer of PAH (cationic electrolyte) are the main driving force allowing the growth of the LbL and LB films, which favors the growth of the cationic phospholipids. The morphology was analyzed through optical microscopy, AFM and SEM, revealing that the phospholipids are structured as vesicles in the LbL films and as monolayers in the LB films. Different thickness of LbL and as monolayers in the LB filma containing phospholipids were deposited onto Pt interdigitated electrodes forming sensingn units applied in the detection of MB using impedance spectroscopy. The results showed that the different molecular architectures of the LbL and LB films take to different eletrical responses and allow the MP detection in concentrations of nanomolar. The SERS technique was applied to obtain structural information of the system MP/phospholipids at the dilution levels reached via impedance spectroscopy at the dilution levels reached via impedance spectroscopy. Then, LB monolayers were deposited onto 6nm of Ag evaporated films with and Ag evaporated films with and Ag nanoparticles were dispersed within the LbL films. The presence of Ag forming nanoparticles in both cases played a key role in achieving the MB SERRS signal allowing obtaining the detection in high dilution levels, approaching... (Complete abstract click electronic access below) / Mestre
39

Espectrometria de absorção atômica e molecular de alta resolução com fonte contínua e forno de grafite : possibilidades e aplicações analíticas

Boschetti, Wiliam January 2016 (has links)
Este trabalho apresenta o desenvolvimento de métodos analíticos que exploram inovações trazidas pela espectrometria de absorção atômica e molecular de alta resolução com fonte contínua (HR-CS AAS e MAS): corrigir interferências espectrais (atômicas e moleculares), realizar determinações multielementares (sequenciais e/ou simultâneas) e determinar a concentração de elementos através de moléculas diatômicas. A alta resolução da técnica, aliada ao uso do forno de grafite, possibilita a análise direta de amostras sólidas e líquidas. As temperaturas utilizadas, em cada método desenvolvido, foram otimizadas visando sinais analíticos com alta sensibilidade e livres de interferências. Dois métodos foram desenvolvidos para determinar Mo e Ni, simultaneamente, em amostras de fertilizantes e vinhos. Paralelamente foi desenvolvido um método para determinar Si em amostras de plantas. Foi desenvolvido, também, um método para determinação sequencial e simultânea de Cd, Cr, Fe e Al em amostras de solo. Ainda considerando amostras de solo, um método para determinar a concentração de F foi desenvolvido utilizando a molécula diatômica de CaF. Os métodos apresentados demonstraram que as técnicas HR-CS GF AAS e MAS permitem analisar amostras de alta complexidade com mínimo pré-tratamento, realizar determinações multielementares e moleculares e empregar linhas analíticas alternativas. / This work presents the development of analytical methods that explore the innovations reached by high-resolution continuum source atomic and molecular absorption spectrometry (HR-CS AAS and MAS): to correct spectral interferences (atomic and molecular), to perform multielement determinations (sequentially and/or simultaneously), and even to use diatomic molecules in order to determine analyte concentrations. The high-resolution of the technique, combined with the use of the graphite furnace, made possible the direct analysis of solid and liquid samples. The temperatures used in each method were optimized aiming for analytical signals with high sensitivity and free of interferences. Two methods were developed to determine Mo and Ni, simultaneously, in fertilizers and wine samples. A method was developed to determine Si in plant samples. A method for sequential and simultaneous determination of Cd, Cr, Fe and Al in soil samples was also developed. Still considering the soil samples, a method for F determination was developed using the CaF diatomic molecule. All methods demonstrate that the HR-CS GF AAS and MAS techniques allow highly complex samples analysis with minimal pretreatment, enabling multielement and molecular determinations employing also alternative analytical lines.
40

Determinação de cádmio e chumbo em cereais por espectrometria de absorção atômica com forno de grafite após combustão iniciada por micro-ondas

Miceli, Tatiane de Macedo January 2015 (has links)
Neste trabalho é proposto um método para a determinação de cádmio e chumbo por espectrometria de absorção atômica com forno de grafite (GF AAS) em cereais (amaranto, chia, linhaça e quinoa) após a decomposição das amostras em sistema fechado por combustão iniciada por micro-ondas (MIC). Para a decomposição por MIC, as amostras foram prensadas na forma de comprimidos e posicionadas em suporte de quartzo, onde a combustão foi feita na presença de 20 bar de oxigênio e utilizando nitrato de amônio como iniciador de combustão (50 μL NH4NO3 6 mol L-1). Foi estudada a concentração da solução absorvedora mais adequada (HNO3 1, 3 e 7 mol L-1), sendo HNO3 7 mol L-1 a solução escolhida por apresentar resultados concordantes (superior a 90%) para o material de referência certificado (CRM). O teor de carbono residual nas soluções obtidas por MIC foi 0,11% e até 500 mg de amostra foram decompostos. Também foram estudados outros métodos de preparo das amostras: decomposição por via úmida em sistema aberto e fechado com aquecimento convencional e decomposição por via úmida em sistema fechado com aquecimento por radiação micro-ondas (MWAD), utilizando sistemas de média (até 40 bar) e alta pressão (até 80 bar). As amostras de cereais não foram completamente decompostas quando o método de decomposição por via úmida em sistema aberto foi utilizado. A decomposição das amostras foi eficiente quando a decomposição por via úmida em sistema fechado (CVWD) com aquecimento convencional e por MWAD foram utilizadas. Apesar destes métodos poderem ser aplicados para a decomposição dos cereais, foram observadas interferências na determinação de Pb por GF AAS. Estas interferências das amostras foram contornadas apenas quando as soluções decompostas por MIC foram analisadas ou utilizando as soluções obtidas por CVWD e MWAD após uma etapa de diluição de, pelo menos, 30 e 50 vezes, respectivamente. Para a determinação de Cd, não foram observadas interferências na etapa de determinação. As concentrações de Cd e Pb em todas as amostras de cereais decompostas por MIC ficaram abaixo do limite de quantificação, de 0,087 e 0,443 μg g-1, respectivamente. / In this work, a method for cadmium and lead determination by graphite furnace atomic absorption spectrometry (GF AAS) in cereals, after microwave-induced combustion (MIC) in closed vessels is proposed. For MIC digestion, samples were pressed as pellets and placed on a quartz holder positioned inside to quartz vessels, where combustion takes place with using 20 bar of oxygen and ammonium nitrate as aid for ignition (50 μL 6 mol L-1 NH4NO3). The concentration of the absorbing solution was evaluated and 7 mol L-1 HNO3 was selected as absorbing solution in view of the agreement (higher than 90%) with the certified reference material. The residual carbon content in digests obtained by MIC was 0.11% and up to 500 mg of sample could be digested. Other sample preparation methods were also evaluated: wet digestion in open and closed vessels under conventional heating and by microwave-assisted wet digestion (MWAD), using systems operating at medium (up to 40 bar) and high pressure (up to 80 bar). Cereals samples were not complete digested when wet digestion in open vessels was used. Digestion was complete when wet digestion in closed vessels (CVWD) under conventional heating and by MWAD were used. Despite these method could be applied for digestion of cereals, interferences were observed in Pb determination by GF AAS. The interteferences on Pb determination by GF AAS were minimized only when digests obtained by MIC were analyzed or when solutions obtained by CVWD and MWAD after a dilution step of 30 and 50 times, respectively, were used. For Cd determination by GF AAS interferences were not observed. Concentration of Cd and Pb in all cereals samples investigated after MIC digestion were lower than the limits of quantification of 0.087 e 0.443 μg g-1, respectively.

Page generated in 0.0347 seconds