• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • Tagged with
  • 9
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação agroclimática para o manejo da cultura do arroz, para as microrregiões do Triângulo Mineiro e Alto Paranaíba

Souza, Amaury de 28 October 1988 (has links)
Submitted by Nathália Faria da Silva (nathaliafsilva.ufv@gmail.com) on 2017-07-20T13:45:42Z No. of bitstreams: 1 texto completo.pdf: 35741364 bytes, checksum: e59c7bdeeb4e8cc0260e5d1ce1d10d35 (MD5) / Made available in DSpace on 2017-07-20T13:45:42Z (GMT). No. of bitstreams: 1 texto completo.pdf: 35741364 bytes, checksum: e59c7bdeeb4e8cc0260e5d1ce1d10d35 (MD5) Previous issue date: 1988-10-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Foram estudadas as exigências bioclimáticas dos cultivares de arroz IAC-47, IAC-165, IAC-164 e IAC-25, nas condições do Estado de Minas Gerais, baseando-se em dados fenológicos obtidos de experimentos conduzidos peia Empresa de Pesquisa Agropecuária de Minas Gerais (EPAMIG), na Estação Experimental de Uberaba, MG, durante os anos agrícolas 1977/78, 1978/79 e 1979/80, com diferentes épocas de plantio por ano agrícola. Inicialmente foram analisadas as distribuições anuais da precipitação média semana], determinadas com base nas séries dos totais diários de precipitação de seis estações meteorológicas do Estado de Minas Gerais. Com base nas curvas de evapotranspiração potencial e de precipitações médias de cada localidade, foram determinadas as respectivas estações de crescimento. Os graus-dia acumulados pelo método WB 10-30,exigidos pelos cultivares de arroz IAC-47, IAC-164, IAC-165 e IAC-25 para completarem as fases fenológicas plantio/floração e plantio/maturação, foram, em média, 1.555, 1.947, 1.229, 1.608, 1.210, 1.611, 1.193 e 1.615, respectivamente. Com base nas exigências de graus-dia dos quatro cultivares de arroz e utilizando médias semanais de precipitação e de evapotranspiração potencial para as localidades de Uberaba, Frutal. Capinópolis, Patrocínio, Araxá e Uberlândia, foram feitas analises agroclimáticas para a cultura do arroz na estação de crescimento de cada local, considerando as melhores épocas de plantio para a cultura, as semanas com totais pluviométricos superiores a 28 mm, assumindo um consumo de água de cerca de 4 mm/dia pela cultura. Para determinar a não-ocorrência de déficit hídrico acentuado na fase do florescimento, foi feita análise probabilística, com segurança de 70%, permitindo a recomendação de épocas de plantio que proporcionem menores riscos de perda total da cultura ou diminuição da produção final.
2

Avaliação do sombreamento e da iluminação natural em apartamentos de edifícios residenciais verticais multifamiliares de Maceió-AL: o uso de varandas. / Evaluation of daylighting and shading in residencial buildings at Maceió-AL: the use of balcony.

Carvalho, Camila Antunes de 21 June 2010 (has links)
In regions with hot and humid tropical climate, as Maceió-AL, the use of daylight, natural ventilation and shading should be thought from the initial stages of the project. To enhance shading, architectural elements as brises-soleil, perforated blocks and balconies are essential to buildings. In the case of balconies, today we see the use of random on environmental issues. As a consequence, and solution for the discomfort caused by the absence of appropriate elements of weather, the use of artificial means to ensure the thermal and visual comfort is intensified contributing to wasted energy. Given this context, this study aims evaluat the use of balconies in vertical multifamily residential apartments buildings located in Ponta Verde, Maceió-AL, as shading and daylighting. To achieve this, the methodology was a comparative analysis of recurring types of balconies on the shading and daylight devices, through the techniques of data collection, generation of shadow masks and simulations in the program Sketchup and Tropilux. The analysis of results provided an understanding of the behavior of shading and daylighting in the typologies examined and also the comparison between the simulation results of heatstroke and the results of simulation of daylighting. Since opting for a better strategy of shading, using the balconies, it is not always achieved a good result in the performance of daylight indoors. Finally, the use of balconies in residential buildings of Maceió, that can be worked to achieve better results in environmental comfort and to enrich the formal aspect of the buildings, should be considered at an early stage of the architectural design / Fundação de Amparo a Pesquisa do Estado de Alagoas / Nas regiões de clima tropical quente e úmido, como é o caso de Maceió-AL, o aproveitamento das fontes de iluminação e ventilação naturais e o uso do sombreamento devem ser pensados desde as etapas iniciais do projeto. Para favorecer o sombreamento, elementos como brises, cobogós e varandas são indispensáveis às edificações. No caso das varandas, atualmente, percebe-se a sua utilização de forma aleatória quanto às questões ambientais. Como consequência disso e para sanar o desconforto gerado pela ausência de elementos adequados ao clima, intensifica-se o uso de meios artificiais para garantir o conforto nos ambientes, contribuindo para o desperdício de energia. Diante desse contexto, esse trabalho tem como objetivo geral avaliar o uso de varandas em apartamentos de edifícios residenciais verticais multifamiliares localizados no bairro de Ponta Verde, em Maceió-AL, quanto ao sombreamento e à iluminação natural. Para alcançá-lo, a metodologia utilizada consistiu de uma análise comparativa entre tipologias recorrentes de varandas, quanto ao sombreamento e a iluminação natural, através das técnicas de levantamento de dados, geração de máscaras de sombra e simulações nos programas computacionais Sketchup e Troplux. As análises dos resultados possibilitaram a compreensão do comportamento do sombreamento e da iluminação natural nas tipologias examinadas e ainda a análise comparativa entre os resultados das simulações de insolação e da iluminação natural. Constatou-se que, uma vez optando por uma melhor estratégia de sombreamento, utilizando as varandas, nem sempre será obtido um bom resultado no desempenho luminoso dos ambientes internos. Enfim, o uso de varanda nos edifícios residenciais de Maceió pode ser trabalhado para alcançar melhores resultados no conforto ambiental e para enriquecer o aspecto formal dos edifícios, devendo ser pensado desde a fase inicial do projeto arquitetônico
3

Requalificação de edifícios: anteprojeto arquitetônico do centro de convivência Djalma Marinho da UFRN com enfoque na eficiência energética da envoltória

Costa, Karilene Rochink 26 July 2017 (has links)
Submitted by Automação e Estatística (sst@bczm.ufrn.br) on 2018-05-03T22:11:51Z No. of bitstreams: 1 KarileneRochinkCosta_DISSERT.pdf: 46373619 bytes, checksum: 10966d69b973d4d258723a7674dd3206 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2018-05-14T19:37:35Z (GMT) No. of bitstreams: 1 KarileneRochinkCosta_DISSERT.pdf: 46373619 bytes, checksum: 10966d69b973d4d258723a7674dd3206 (MD5) / Made available in DSpace on 2018-05-14T19:37:35Z (GMT). No. of bitstreams: 1 KarileneRochinkCosta_DISSERT.pdf: 46373619 bytes, checksum: 10966d69b973d4d258723a7674dd3206 (MD5) Previous issue date: 2017-07-26 / O presente estudo aborda a temática da Requalificação de edifícios, com foco na eficiência energética da envoltória. O projeto se propõe a promover a requalificação do edifício do Centro de Convivência Djalma Marinho, localizado no Campus Central da Universidade Federal do Rio Grande do Norte, localizado em Natal/RN. Partiu da Avaliação pós-ocupação do ambiente construído, para elaborar um diagnóstico da problemática do conforto térmico no prédio atual e proposição de uma nova programação arquitetônica para o espaço. Através da aplicação de estratégias bioclimáticas passivas, recomendadas para a Zona bioclimática brasileira nº 08, o projeto pretende reduzir a transferência de calor do ambiente externo para o ambiente interno, melhorar o conforto térmico dos usuários e reduzir o consumo energético da edificação. As ações propostas objetivam a melhoria do desempenho energético e térmico da envoltória da edificação, para obtenção da Etiqueta Nacional de eficiência energética da Edificação (ENCE/PROCEL), assim como oferecer à comunidade acadêmica um espaço requalificado com qualidade ambiental. A racionalização dos materiais e recursos resultou em um projeto passível de execução que obteve, segundo o WebPrescritivo, a etiqueta correspondente à classe de eficiência "A" para a envoltória. Neste projeto arquitetônico de requalificação trabalhou-se principalmente as propriedade térmicas dos materiais e os sistemas construtivos empregados. / This study addresses building requalification focusing on the envelope’s energy efficiency. The work proposes a requalification for Centro de Convivência Djalma Marinho’s building, located in UFRN’s main campus in Natal/RN. From a Post-Occupancy Evaluation of the built environment, an analysis about the existing building’s thermal comfort conditions was performed, and a new architectural brief was proposed. By applying passive bioclimatic strategies, as recommended for Brazilian Bioclimatic Zone 08, the design intention is reducing heat transfer from the external environment to the internal environment, improving thermal comfort for users and reducing energy consumption. The presented actions aim an enhancement of the building envelope’s energy and thermal performances, to obtain the Etiqueta Nacional de Eficiência Energética da Edificação (PROCEL), and offer the academic community a space with better environmental quality. Rationalizing materials and resources resulted in an executable design, which according to WebPrescritivo, obtained a label corresponding to class “A” for building envelope. This architectural design for requalification emphasized thermal properties of materials and the employed building systems.
4

Fatores multidimensionais para avaliação da sensação térmica em escritórios individuais /

Santos, Ana Carolina dos. January 2019 (has links)
Orientador: João Roberto Gomes de Faria / Resumo: O modo como são projetados e ocupados os espaços de trabalho interferem tanto em como as pessoas se sentem como em seu desempenho. Oferecer um ambiente interno confortável é necessário para que seus ocupantes alcancem um melhor desempenho. Assim, um dos principais fatores para que um ambiente possua qualidade interna é que este seja termicamente confortável. Neste sentido, as escolhas arquitetônicas têm a capacidade de proporcionar experiências, sejam elas físicas, funcionais ou psicológicas, capazes de influenciar na percepção térmica de seus ocupantes. Por sua vez, os usuários de salas individuais têm papel fundamental no ajuste dos sistemas que visam estabelecer condições de conforto térmico de suas salas. Sendo assim, o objetivo do trabalho foi verificar, através de uma análise exploratória, como o uso de estratégias bioclimáticas para a obtenção do conforto ambiental por usuários de escritórios individuais é capaz de influenciar a sensação térmica. Para isto, um estudo de caso foi realizado com os docentes e suas salas de escritórios individuais dos quatro prédios de departamento da Faculdade de Arquitetura, Artes e Comunicação (FAAC) da Unesp, Campus de Bauru: Design; Arquitetura, Urbanismo e Paisagismo; Ciências Humanas; Artes e Representação Gráfica. Foi adotado na pesquisa um método misto com avaliações quantitativas e qualitativas através, respectivamente, de simulação computacional e aplicação de questionários. Os resultados mostraram que usuários de escritórios in... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The way workspaces are designed and occupied interfere with how people feel and in their performance. Providing a comfortable indoor environment is necessary for their occupants to achieve better performance. Thus, one of the main factors for the quality of an environment is that it is thermally comfortable. In this sense, architectural choices have the ability to provide experiences, whether physical, functional or psychological, capable of influencing the thermal perception of their occupants. In turn, users of individual rooms play a fundamental role in adjusting the systems that aim to establish thermal comfort conditions of their rooms. Thus, the objective of the study was to verify, through an exploratory analysis, how the use of bioclimatic strategies to obtain environmental comfort by individual office users is able to influence the thermal sensation. For this, a case study was conducted with the teachers and their individual office rooms of the four department buildings at School of Architecture, Arts and Communication of São Paulo State University (UNESP), campus Bauru: Design; Architecture, Urbanism and Landscaping; Humanities; and Arts and Graphic Representation. The research adopted a mixed method with quantitative and qualitative evaluations through, respectively, computer simulation and questionnaires application. The results showed that users of individual offices can have their perception and thermal comfort influenced by non-thermal variables and that the ps... (Complete abstract click electronic access below) / Mestre
5

Análise do COP anual de condicionadores de ar tipo Split fixo e inverter nas diferentes zonas bioclimáticas brasileiras

Rech, Letícia Dotta 12 April 2018 (has links)
Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2018-08-01T14:35:36Z No. of bitstreams: 1 Letícia Dotta Rech_.pdf: 7163933 bytes, checksum: b8456d05a1d302c866b6a463943d0889 (MD5) / Made available in DSpace on 2018-08-01T14:35:36Z (GMT). No. of bitstreams: 1 Letícia Dotta Rech_.pdf: 7163933 bytes, checksum: b8456d05a1d302c866b6a463943d0889 (MD5) Previous issue date: 2018-04-12 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho apresenta uma análise da relação entre o desempenho de equipamentos de condicionamento de ar tipo Split, fixo e inverter, para a climatização de uma edificação comercial nas diferentes zonas bioclimáticas brasileiras. As análises foram realizadas por simulação computacional, através do programa EnergyPlus. Foram simulados oito casos seguidos pelo modelo de referência. O modelo de referência adotado foi criado a partir de um levantamento fotográfico de edificações comerciais padrões com mais de quatro pavimentos. A partir deste levantamento, a tipologia que foi adotada representa um edifício de dez pavimentos com perímetro de dimensões de 27 por 7,50 metros e, pé-direito de 2,60 metros. Para analisar o comportamento energético do modelo de referência foram inseridos dados dos componentes construtivos, do padrão de ocupação, das cargas energéticas do sistema de iluminação e dos equipamentos, do condicionamento de ar, com as suas respectivas curvas de desempenho, conforme fornecedor, e de infiltração, conforme norma. Com esses dados inseridos no EnergyPlus, foi possível dimensionar a carga térmica dos equipamentos de ar condicionado e seu desempenho energético, analisados através do COP anual simulado desses equipamentos. Com a simulação foi possível destacar os fatores que influenciam no consumo de energia de um sistema de ar condicionado no que diz respeito às condições climáticas, principalemente o impacto da temperatura externo no desempenho do equipamento. Nos resultados encontrados foi possível identificar que existe uma influência bastante significativa, principalmente quando se comparam regiões de alta temperatura externa e com de baixa temperatura externa e, em um segundo momento, valores altos e baixos de umidade relativa interna do ar ambiente, sendo que, altas umidades favorecem o desempenho do equipamento avaliado. Resultados bastante significativos foram encontrados na substituição de aparelhos Split fixo por aparelhos Split inverter, nos quais se alcançou uma redução de até 44% de economia em regiões específicas do país, seu COP anual simulado apresentou um indicador mais eficiente em todas as horas simuladas. / This work presents an analysis of the relationship between the performance of split, fixed and inverter air conditioning equipment for the air conditioning of a commercial building in the different Brazilian bioclimatic zones. Analyzes were performed by computer simulation using the EnergyPlus program. Eight cases followed by the reference model were simulated. The reference model adopted was created from a photographic survey of standard commercial buildings with more than four floors. From this survey, the typology that was adopted represents a ten-storey building with a perimeter of dimensions of 27 by 7.50 meters and, at the foot of 2.60 meters. In order to analyze the energy performance of the reference model, data were included on the building components, occupancy pattern, energy loads of the lighting system and equipment, air conditioning, with their respective performance curves, as supplier, and infiltration, according to norm. With these data inserted in the EnergyPlus, it was possible to measure the thermal load of the air conditioning equipment and their energy performance, analyzed through the simulated annual COP of this equipment. With the simulation, it was possible to highlight the factors that influence the energy consumption of an air conditioning system with regard to climatic conditions, mainly the impact of external temperature on the performance of the equipment. In the results, it was possible to identify that there is a significant influence, especially when comparing high temperature and external low temperature regions, and in a second moment, high and low values of internal relative humidity of the ambient air, high performance favors the performance of the equipment evaluated. Significant results were found in the replacement of fixed split devices with split inverter devices, in which a reduction of up to 44% of savings was achieved in specific regions of the country, its annual simulated COP showed a more efficient indicator at all simulated hours.
6

Conforto ambiental como parâmetro para construção de novas habitações rurais na região do médio São Francisco, semiárido baiano

Simões, Carla Carvalho January 2009 (has links)
166f. / Submitted by Suelen Reis (suziy.ellen@gmail.com) on 2013-04-09T19:24:29Z No. of bitstreams: 1 Dissert Carla.pdf: 17346330 bytes, checksum: 30322ce1540276be3d2331f322f0b597 (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-05-09T18:16:23Z (GMT) No. of bitstreams: 1 Dissert Carla.pdf: 17346330 bytes, checksum: 30322ce1540276be3d2331f322f0b597 (MD5) / Made available in DSpace on 2013-05-09T18:16:23Z (GMT). No. of bitstreams: 1 Dissert Carla.pdf: 17346330 bytes, checksum: 30322ce1540276be3d2331f322f0b597 (MD5) Previous issue date: 2009 / A pesquisa investiga a aplicação de estratégias de conforto ambiental como parâmetros construtivos em um modelo icônico de casa estável para novas habitações no meio rural do Distrito dos Brejos, município de Barra, região do médio São Francisco, semiárido baiano. A partir da análise das variáveis climáticas e das tipologias construtivas da região, foi possível identificar parâmetros e diretrizes para concepção de um modelo de casa estável para novas habitações. O presente trabalho descreve com um olhar tecnológico, uma nova concepção de projeto pelo qual se considera os fluxos de materiais e energia, compatibilizando com outros enfoques sociais, econômicos, culturais e ambientais. Esse trabalho envolve inclusive a reeducação ambiental e a qualificação da mão de obra, formal e informal de seus usuários e construtores em mutirão. Foram empregadas análises de soluções tecnológicas aplicáveis as habitações da região do estudo de caso, associada a um diagnóstico climático considerado fundamental para determinar estratégias bioclimáticas. O resultado obtido na pesquisa é um modelo virtual de casa estável, adaptada ao meio ambiente externo, para estudos tridimensionais das especificidades dos locais onde novos projetos de habitação e assentamentos serão implantados. Através de modelo 3D e animações simuladas em ambientes computacionais, essa pesquisa revelou ainda a viabilidade de estudos tridimensionais em modelos virtuais como ferramenta capaz de testar a aplicação de soluções tecnológicas que contemplam diretrizes climáticas e os parâmetros construtivos propostos como forma de contribuir para as estratégias de desenvolvimento da sociedade local. / Salvador
7

Clima e arquitetura habitacional em Alagoas: estratégias bioclimáticas para Maceió, Palmeira dos Índios e Pão de Açúcar. / Climate and qrchitecture in Alagoas : bioclimatic design strategies in Maceió, Palmeira dos Índios and Pão de Açúcar.

Passos, Isabela Cristina da Silva 06 May 2009 (has links)
In Brazil, the lack of meteorological data is an issue in order to apply a bioclimatic approach for building design. As one of the consequences, designers frequently apply general climate data from one region to another rather than specific data for design strategies purposes. However, this general climate data not necessarily represent accurately microclimatic conditions for different cities even when they are part of the same region. Facing this, this work discusses design strategies for bioclimatic housing in Maceió, Palmeira dos Índios and Pão de Açúcar, located in different geographical mesoregions in Alagoas, in order to adapt to local climate, to thermal comfort, energy efficiency and sustainability of the living space. The methodological steps were: choice of cities, field research, meteorological data evaluation and buildings design recommendations discussion. Meteorological data for approximately ten years was used, obtained from INMET (National Institute of Meteorology) and processed by statistical analysis and the methods of Test Reference Year (TRY) and Project Typical Day. The results showed that there are differences between the cities, especially about annual temperature range, precipitation and direction of winds. The main bioclimatic strategies recommended were: shading, ventilation and protection from rain for Maceió; shading, ventilation, protection from rain and high-mass in daily use rooms for Palmeira dos Índios and shading, ventilation, high-mass in daily use rooms and evaporative cooling for Pão de Açúcar. Besides that, inconsistencies between the recommendations made by the NBR 15220-3 for cities and the data analyzed were found. / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / No Brasil, a escassez de dados meteorológicos ainda é um desafio e em conseqüência disto, muitas vezes, o clima é desconsiderado ou adotado de maneira generalista na prática arquitetônica. Diante disto, o presente trabalho discute estratégias bioclimáticas para habitação nas cidades de Maceió, Palmeira dos Índios e Pão de Açúcar, localizadas nas diferentes Mesorregiões Geográficas do Estado de Alagoas, de forma que se adaptem ao clima local, visando conforto térmico, eficiência energética e sustentabilidade do espaço habitado. Os procedimentos metodológicos adotados foram: escolha das cidades; pesquisa de campo; tratamento e análise de dados meteorológicos e discussão das recomendações de projeto. Foram utilizados dados meteorológicos de um período de aproximadamente dez anos, obtidos junto ao INMET (Instituo Nacional de Meteorologia), tratados através de análise estatística e das metodologias de Ano Climático de Referência e Dia Típico de Projeto. Os resultados mostraram que, existem diferenças climáticas entre as cidades, em especial quanto à amplitude térmica anual, precipitação e direção dos ventos. As principais estratégias bioclimáticas recomendadas para as cidades foram: sombreamento, ventilação e proteção contra as chuvas para Maceió; sombreamento, ventilação, proteção contra as chuvas e massa térmica para resfriamento em ambientes de uso diurno para Palmeira dos Índios e sombreamento, ventilação, massa térmica para resfriamento em ambientes de uso diurno e resfriamento evaporativo para Pão de Açúcar. Além disto, foram identificadas contradições entre as recomendações feitas pela NBR 15.220-3 para as cidades e os dados analisados.
8

Desempenho térmico de habitações populares em Alagoas: alternativas para adequação climática / Thermal performance popular housing in Alagoas: alternatives to climate adequacy

Torres, Daniela de Araújo 19 March 2015 (has links)
The thermal performance is an important factor to be studied regarding habitability conditions in the built environment, as it directly affects the individuals life quality. The lowincome population, which can't afford artificial air conditioning systems depends on project adapted to the weather maintenance costs require with efficient thermal conditioning passive strategies. The popular housing units built under the Minha Casa Minha Vida (PMCMV) federal government programme follow a similar constructive and architectural pattern, despite the diversity of sites in which the buildings are located, resulting in unsuitable thermal environments inside buildings. Thus, new models are proposed adapteding the Model Base, PMCMV standard, using passive strategies, such as natural ventilation, thermal mass and evaporative cooling in order to obtain quantitative results of the thermal performance of a housing unity in different climates of the state of Alagoas, considering the cities: Maceio (east), Palmeira dos Índios (western) and Pão de Açúcar (backlands), ranging from warm and humid to hot and dry climate. Through qualitative studies and using computer simulation method with the Energyplus software. 8.1 it assessed the thermal performance of models, design in accordance with the recommended strategies for each region. It assessed as evaluation criterion the number of degree-hours of discomfort based on a pre-set operative comfort temperature inside of the house rooms. A comparative analysis is then carried out, identifying the best models for each city studied from the point of view of thermal performance. Results showed that the adoption of hybrid strategy yielded a better performance. The adapted model 3E, which includes natural ventilation strategy, thermal mass and evaporative cooling achieved the best results, with a reduction of more than 50% of the total degree-hour discomfort regarding the Base Model, MCMV pattern, in the three cities. The adapted model V_MT (ventilation and thermal mass) had the smallest reduction, less than 15%, in Palmeira dos Índios and Pão de Açúcar, where it was simulated. / O desempenho térmico é um importante fator a ser estudado para que condições de habitabilidade sejam alcançadas no ambiente construído, pois interfere diretamente na qualidade de vida dos indivíduos. A população de baixa renda, que não possui condições financeiras para adquirir e usufruir de sistemas artificiais de condicionamento de ar, depende de um projeto adaptado ao clima, com estratégias de condicionamento térmico passivas. As unidades habitacionais populares construídas no âmbito do Programa Minha Casa Minha Vida (PMCMV) do governo federal seguem um padrão construtivo com pouca diferenciação arquitetônica, apesar da diversidade de locais no qual é implantado, resultando em ambientes termicamente inadequados. Deste modo são propostos novos modelos adaptados ao Modelo Base, padrão PMCMV, utilizando estratégias passivas de condicionamento térmico, como ventilação natural, massa térmica e resfriamento evaporativo, a fim de obter resultados quantitativos do comportamento da edificação nas diferentes realidades climáticas do estado de Alagoas, considerando as cidades: Maceió (leste), Palmeira dos Índios (agreste) e Pão de Açúcar (sertão), variando do clima quente e úmido ao semiárido. Através de estudos qualitativos e utilizando o método de simulação computacional, com o emprego do software Energyplus v. 8.1 é avaliado o desempenho térmico dos modelos adaptados, com as estratégias recomendadas para cada região. O critério de avaliação adotado foi o número de graus-horas de desconforto por calor, em função do limite de conforto pré-estabelecido para a temperatura operativa verificada no interior dos ambientes. É realizada então, uma análise comparativa, identificando qual o modelo mais apropriado para cada cidade estudada, sob o ponto de vista do desempenho térmico. Os resultados mostraram que a adoção de estratégias híbridas proporcionou um melhor desempenho para os modelos. O modelo adaptado 3E, o qual inclui a estratégia de ventilação natural, massa térmica e resfriamento evaporativo obteve os melhores resultados, com uma redução em mais de 50% do somatório do graus-hora de desconforto por calor, em relação ao Modelo Base, padrão MCMV, nas três cidades. O modelo adaptado V_MT (ventilação e massa térmica) obteve a menor redução, com menos de 15% no somatório de graus-hora, nas cidades de Palmeira dos Índios e Pão de Açúcar, onde foi simulado.
9

Efeito potencial de mudanças climáticas sobre a distribuição de Phyllomedusa centralis (Anura : Hylidae)

Arruda, Luana Aparecida Gomes de 02 December 2014 (has links)
Submitted by Valquíria Barbieri (kikibarbi@hotmail.com) on 2018-04-05T22:00:26Z No. of bitstreams: 1 DISS_2014_Luana Aparecida Gomes de Arruda.pdf: 854132 bytes, checksum: e5dce680d3fc443608aec08b5e456321 (MD5) / Approved for entry into archive by Jordan (jordanbiblio@gmail.com) on 2018-04-23T18:21:48Z (GMT) No. of bitstreams: 1 DISS_2014_Luana Aparecida Gomes de Arruda.pdf: 854132 bytes, checksum: e5dce680d3fc443608aec08b5e456321 (MD5) / Made available in DSpace on 2018-04-23T18:21:48Z (GMT). No. of bitstreams: 1 DISS_2014_Luana Aparecida Gomes de Arruda.pdf: 854132 bytes, checksum: e5dce680d3fc443608aec08b5e456321 (MD5) Previous issue date: 2014-12-02 / Pesquisas em campo voltadas para conservação de espécies são necessárias, porém muitas vezes são limitadas, onerosas e trabalhosas. Uma ferramenta que pode ser utilizada para minimizar estes problemas é a Modelagem Preditiva de Distribuição Potencial de Espécies (MPDPE), que permite estimar áreas potenciais de ocorrência atuais e futuras e que vem recebendo destaque em estudos conservacionistas, pois pode ser utilizada com espécies raras ou que estão sofrendo algum grau de ameaça. No presente estudo, a MPDPE foi utilizada para conhecer a distribuição e prever o efeito potencial de mudanças climáticas sobre a distribuição da perereca Phyllomedusa centralis, que possui distribuição conhecida restrita a poucas localidades no estado de Mato Grosso, Brasil. Os modelos foram desenvolvidos com o método de entropia máxima com o auxilio do programa MaxEnt, utilizando variáveis bioclimáticas atuais e futuras. Os modelos de predição de distribuição atual e de cenários futuros obtiveram elevados valores da área sob a curva operador-receptor e a validação apontou alta precisão na qualidade do modelo. Em todos os modelos, a variável ambiental com maior porcentagem de contribuição foi a precipitação. Todos os modelos apresentaram previsão de aumento nas áreas de distribuição potencial em comparação com o modelo atual de distribuição. Apesar de apresentar limitações, o modelo de distribuição potencial é relevante e pode ajudar no planejamento e gestão de reservas, descoberta de novas populações e manejo de espécies, identificação de áreas prioritárias para conservação e definição de onde é necessária a restauração de habitats. / Field surveys aimed at the conservation of species are necessary, but are often limited, costly and onerous. A tool that can be used to minimize these problems is the Predictive Modeling of Potential Species Distribution (PMPSD), which allows estimating current and future areas of potential occurrence and has received attention from conservationists studies, because it can be used with rare species or who are suffering some degree of threat. In the present study PMPSD was used to determine the distribution and predict the potential effect of climate change on the distribution of tree frog Phyllomedusa centralis, which has restricted distribution to a few localities in the state of Mato Grosso, Brazil. The models were developed with maximum entropy method with the aid of the MaxEnt program using current and future bioclimatic variables. The prediction models of current distribution and future scenarios had higher Area Under the receiver-operator Curve values and the validation showed high accuracy of the model quality. In all models the environmental variable with highest percentage of contribution was precipitation. All models showed increased areas of potential distribution compared with the current distribution model. Despite the limitations, the model of potential distribution is important and can help in planning and management of reserves, discovery of new populations, identification of priority areas for conservation, and definitions of regions to habitat restoration.

Page generated in 0.0502 seconds