• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 187
  • 133
  • 31
  • 11
  • 8
  • 8
  • 5
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 484
  • 148
  • 75
  • 73
  • 47
  • 45
  • 44
  • 43
  • 43
  • 42
  • 40
  • 39
  • 37
  • 34
  • 33
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Síntese, caracterização e avaliação in vivo e in vitro da biocompatibilidade de nanocristais de TiO2

Brito, Patrícia de Freitas Leucas 28 August 2013 (has links)
Fundação de Amparo a Pesquisa do Estado de Minas Gerais / Upon the current need for research with TiO2 nanocrystals (TiO2 NCs) properly characterized in order to evaluate their biological effects, this work was done aiming to synthesize and characterize TiO2 NCs, and evaluate their biocompatibility. The nanoparticles were synthesized by the precipitation in aqueous solution technique, and characterized by the techniques of X-ray diffraction, micro-Raman and spectrophotometry. To evaluate the biocompatibility, TiO2 NCs were tested in vivo using subcutaneous implants using Balb/c mice at a dose of 1g/kg for 15, 30 and 90 days for later histological analysis of the groups of 15 and 90 days and transmission electron microscopy of the group 30 days. In vitro evaluation consisted of cell viability assays, detection and measurement of nitric oxide metabolites and measurement of cytokine production in situ and in cultured macrophages challenged with different concentrations of TiO2 NCs. Cell viability was assessed after 72 hours by the MTT colorimetric assay, using five different concentrations of a solution of 10μg/ml, 20μg/ml, 40μg/ml, 100μg/ml and 200μg/ml in culture challenge of peritoneal macrophages Balb/c mice with 2, 12, 24 and 72 hours. From the supernatant of cultures of peritoneal macrophages was evaluated the production of nitrite by the Griess method and dosage levels of TNF-α, IL-1β, IL-12, IFN- and IL-4 by ELISA. The same technique was used for the determination of cytokine levels obtained from subcutaneous tissues underwent implantation of TiO2 NCs. After analysis of the data distribution by Kolmogorov-Smirnov test, we proceeded to their analysis by the Kruskal-Wallis test with Bonferroni post-test. The experiments of synthesis and characterization resulted in TiO2 nanocrystals of 8.5 nm on average, mixed phase, high purity level and quantum confinement effects. Histological analysis of the 15 days group showed a intense granulomatous nonspefic type inflammatory response with signs of necrosis and hemorrhage, which progressed with a slight reduction in its intensity, observed especially at 90 days of observation. Presence of clusters of nanocrystals with macroscopic dimensions, surrounded by macrophages and multinucled giant cells forming granulomas with fibrous capsules, which could be regarded as a typical reaction of granulomatous foreign body type and more intense fibrosis formation at 90 days within the material deployed. Nanocrystals were identified in lymph nodes in the different periods of study, suggesting that these particles might be transposed. Electron microscopy confirmed the evidence of apoptosis and vacuolar degeneration. The MTT test resulted in 40% viable cells in only 10 and 20μg/ml. The in vitro cytokine assay showed that there was not a tendency dose or time-dependent samples, presenting different behavior of TNF-α, IL-1β, IL-12 and increased production of IFN- probably due to low production of IL -4. The nitrite production was higher in the samples of 10μg/ml. The production of all cytokines in vivo experiment by the 15 days group was enhanced, decreasing in a time-dependent fashion, collaborating with the findings in vivo. We conclude that the TiO2 nanocrystals present in the tested concentrations presented inflammatory effects in vivo, cytotoxic and inflammatory conditions in vitro. These findings show that the experimental conditions studied NCs are not biocompatible. / Mediante a atual necessidade de pesquisas com nanocristais de TiO2 (NCs TiO2) devidamente caracterizados a fim de se avaliar seus efeitos biológicos, realizou-se este trabalho que teve como objetivos a síntese e caracterização dos NCs TiO2, e a avaliação de sua biocompatibilidade. As nanopartículas foram sintetizadas pela técnica da precipitação via solução aquosa, e caracterizadas por meio das técnicas de difração de raios-X, micro-Raman e espectrofotometria. Para a avaliação da biocompatibilidade, os NCs TiO2 foram submetidos a testes in vivo por meio de implantes subcutâneos utilizando camundongos Balb/c na dose de 1g/kg, por 15, 30 e 90 dias para posterior análise histológica dos grupos de 15 e 90 dias e microscopia eletrônica de transmissão do grupo de 30 dias. Avaliação in vitro consistiu de ensaios de viabilidade celular, detecção e mensuração de metabólitos do óxido nítrico e mensuração da produção de citocinas in loco e em cultura de macrófagos desafiados por diferentes concentrações de NCs TiO2. A viabilidade celular foi avaliada após 72 horas pelo teste colorimétrico MTT, utilizando-se cinco concentrações diferentes de solução de 10μg/ml, 20μg/ml, 40μg/ml, 100μg/ml e 200μg/ml, em desafio de cultura de macrófagos peritoneais de camundongos Balb/c por 2, 12, 24 e 72 horas. Do sobrenadante de culturas de macrófagos peritoneais avaliou-se a produção de nitrito pelo método de Griess e dosagem dos níveis das citocinas TNF-α, IL-1β, IL-12, INF- e IL-4 por ELISA. A mesma técnica foi utilizada para a dosagem dos níveis de citocinas obtida dos tecidos subcutâneo submetido ao implante de NCs TiO2. Após a análise da distribuição dos dados pelo teste Kolmogorov-Smirnov, procedeu-se a sua análise por meio do teste de Kruskal-Wallis com pós-teste de Bonferroni. Os experimentos de síntese e caracterização resultaram nanocristais de TiO2 de 8,5nm em média, fase mista, alto grau de pureza e efeitos de confinamento quântico. As análises histológicas do grupo de 15 dias evidenciaram uma resposta inflamatória do tipo granulomatosa inespecífica intensa com sinais de necrose e hemorragia, que evoluiu com discreta redução em sua intensidade, constatada em especial aos 90 dias de observação. Presença de aglomerados de nanocristais de dimensões macroscópicas, rodeados de macrófagos e células gigantes multinucleadas formando granulomas, com cápsulas fibrosas, que poderiam ser consideradas como uma reação típica do tipo granulomatosa de corpo estranho e formação de fibrose mais intensa aos 90 dias no interior do material implantado. Houve a identificação dos nanocristais nos linfonodos nos diferentes períodos de estudo, sugerindo que estas partículas possam ser carreadas a distância. A microscopia eletrônica confirmou a evidência de apoptose e degeneração vacuolar. O teste MTT resultou em 40% de células viáveis somente em 10 e 20μg/ml. A dosagem de citocinas in vitro demonstrou que não houve uma tendência dose ou tempo dependente das amostras, apresentando comportamentos distintos de produção de TNF-α, IL-1β, IL-12 e maior produção de INF- devido provavelmente à baixa produção de IL-4. A produção de nitrito foi maior nas amostras de 10μg/ml. A produção de todas as citocinas do experimento in vivo pelo grupo de 15 dias foi acentuada, decrescendo de forma tempo dependente, colaborando com os achados in vivo. Conclui-se que os nanocristais de TiO2 nas concentrações testadas apresentaram efeitos inflamatórios in vivo, citotóxicos e inflamatórios in vitro. Estes achados atestam que nas condições experimentais utilizadas os NCs estudados não são biocompatíveis. / Mestre em Odontologia
102

Incidência de recessão gengival e fatores de risco e de prognóstico associados : estudo longitudinal prospectivo de base populacional

Rios, Fernando Silva January 2017 (has links)
Este estudo teve como objetivo avaliar a citotoxicidade, biocompatibilidade e perfil osteoindutor de um novo material a base de MTA (MTA Flow) comparado ao AH plus e MTA fillapex. A viabilidade celular foi avaliada em células-tronco do ligamento periodontal pelo teste MTT. A resposta inflamatória e o perfil osteoindutor foram avaliados em tecido conjuntivo de 24 ratos machos (Rattus norvegicus albinus, Rodentia, Mammalia da linhagem Wistar), pesando entre 300 e 350g. Os animais foram divididos em 4 grupos experimentais. Foram implantados 4 tubos de polietileno no dorso de cada animal, sendo um vazio e outros três preenchidos com um dos materiais. Após 7, 30 e 60 dias, 8 animais foram mortos com anestésico inalatório. O tubo e o tecido subcutâneo adjacente foram removidos e fixados em solução de formalina a 10%. O material foi analisado histológicamente quanto ao processo inflamatório, condensação fibrosa e presença de abscesso. Posteriormente, realizou-se a análise imunoistoquímica para identificação de colágeno I, osteopontina, sialoproteina óssea e proteína morfogentica óssea-4 (BMP-4). Os dados foram analisados estatisticamente pela ANOVA, complementado pelo teste de Tukey usando SPSS 15.0. O MTA Flow mostrou não ser citotóxico e ter excelente biocompatibilidade com menor reação inflamatória no tecido subcutâneo de ratos em comparação com AH Plus e MTA Fillapex. Além disso, o MTA Flow mostrou ser capaz de estimular o processo mineralização, sendo uma vantagem em relação aos outros materiais testados. / This study aimed to evaluate the cytotoxicity, biocompatibility and osteoinductive profile of a new MTA based material (MTA Flow) compared to AH plus and MTA fillapex. Cell viability was evaluated in periodontal ligament stem cells by the MTT test. The inflammatory response and the osteoinductive profile were evaluated in the connective tissue of 24 male rats (Rattus norvegicus albinus, Rodentia, Mammalia of the Wistar line) weighing between 300 and 350g. The animals were divided into 4 experimental groups. Four polyethylene tubes were implanted on the back of each animal, one empty and another three filled with one of the materials. After 7, 30 and 60 days, 8 animals were killed with inhaled anesthetic. The tube and adjacent subcutaneous tissue were removed and fixed in 10% formalin solution. The material was analyzed histologically for the inflammatory process, fibrous condensation and presence of abscess. Subsequently, the immunohistochemical analysis was performed to identify collagen I, osteopontin, bone sialoprotein and bone morphogenetic protein-4 (BMP-4). Data were analyzed statistically by ANOVA, complemented by the Tukey test using SPSS 15.0. MTA Flow was shown to be non-cytotoxic and to have excellent biocompatibility with lower inflammatory reaction in rat subcutaneous tissue compared to AH Plus and MTA Fillapex. In addition, the MTA Flow showed to be able to stimulate the mineralization process, being an advantage over the other materials tested.
103

Avaliação do comportamento biológico do cimento endodôntico MTA Fillapex em tecido ósseo de ratos / Evaluation of rat bone tissue response to MTA Fillapex

Assmann, Eloísa January 2013 (has links)
Introdução: A biocompatibilidade é uma propriedade importante e necessária a um cimento endodôntico. O objetivo do presente estudo foi fazer uma análise microscópica das reações do tecido ósseo do fêmur de ratos da linhagem Wistar frente ao cimento MTA Fillapex, comparando-as ao cimento AH Plus e ao grupo controle (cavidade vazia), nos períodos de 7, 30 e 90 dias. Materiais e Métodos: Foram utilizados 18 animais, divididos em 3 grupos, de acordo com o período experimental (n=6). Três cavidades foram preparadas no fêmur da pata traseira direita de cada animal, sendo que uma foi preenchida com AH Plus, a outra com MTA Fillapex e a última permaneceu vazia (controle negativo). Decorridos os períodos experimentais, os ratos foram mortos e as patas removidas, dissecadas e preparadas para análise histológica. Os cortes foram analisados em microscópico óptico. O infiltrado inflamatório e as zonas de calcificação foram avaliados de forma dicotômica (presente ou ausente). A formação de barreira óssea foi classificada como ausente, parcial ou completa. Testes estatísticos não-paramétricos foram utilizados para a comparação dos dados (p<0,05). Resultados: As comparações entre os períodos experimentais mostraram que aos 7 dias todos os grupos apresentaram menor formação de barreira óssea e que o MTA Fillapex apresentou mais áreas de calcificação em relação aos demais períodos. Nos grupos do AH Plus e do MTA Fillapex, o infiltrado inflamatório reduziu significativamente aos 90 dias. As comparações entre os grupos mostraram mais áreas de calcificação no grupo do AH Plus aos 30 e 90 dias. O grupo controle apresentou menos infiltrado inflamatório aos 30 dias. Não houve diferença significativa entre os grupos na formação de barreira óssea. Conclusões: O cimento endodôntico MTA Fillapex apresentou comportamento biológico satisfatório em contato direto com tecido ósseo de rato. As características do reparo foram semelhantes às do cimento AH Plus, porém o MTA Fillapex não induziu a formação de áreas de calcificação na medula óssea. / Introduction: Biocompatibility is an important property required for a endodontic sealer. This study aimed to analyze bone tissue reactions to MTA Fillapex compared to an epoxy resin-based material in the femur of Wistar rats. Methods: Bone tissue reactions were evaluated in 18 animals after 7, 30 and 90 days (n=6 per period). Three surgical cavities were prepared on femur and filled with 0.1 mL of AH Plus, MTA Fillapex or no sealer (negative control). By the end of each experimental period, six animals were randomly euthanized, the femur was dissected and the surgical cavities separated. The samples were histologically processed and analyzed by light microscope. Inflammatory infiltrate and the calcification zones were evaluated dichotomously; hard tissue barrier was classified as absent, partial or full. Results: Comparison among periods showed that at 7 days all groups presented less hard tissue barrier and MTA Fillapex showed more calcification zones than in other periods. The inflammatory infiltrate significantly reduced at 90 days in AH Plus and MTA Fillapex groups. Comparisons among the groups presented more calcification zones for AH Plus than for the other groups at 30 and 90 days. Control group showed less inflammatory infiltrate at 30 days. There were no singificant diferences to hard tissue barrier among the groups. Data were analyzed by non-parameric tests. Significance level was preset in 0.05. Conclusions: MTA Fillapex presented satisfactory biological behaviour when in direct contact with rat bone tissue. The repair characteristics were similar to those produced by AH Plus, but MTA Fillapex doesn’t induce mineralization in the bone marrow.
104

Migração celular, viabilidade e reação tecidual de soluções irrigadoras à base de hipoclorito de cálcio : estudo in vitro e in vivo / Cell migration, viability and tissue reaction of calcium hypochlorite based‐solutions irrigants : an in vitro and in vivo study

Blattes, Gabriela Bess Ferraz January 2015 (has links)
Introdução: O objetivo do presente estudo foi analisar a citotoxicidade e biocompatibilidade de soluções de hipoclorito de cálcio (Ca(OCl)2) comparadas a soluções de hipoclorito de sódio (NaOCl) in vitro em cultura de fibroblastos 3T3 e in vivo em ratos. Metodologia: Culturas de fibroblastos 3T3 foram expostas a diferentes concentrações de hipoclorito de cálcio e sódio e foi realizado um ensaio de “scratch”. Além disso, a taxa de viabilidade foi analisada utilizando o teste Azul de Trypan. As soluções a 1 e 2,5% foram, também, injetadas no tecido conjuntivo de 18 ratos Wistar de 18 semanas de idade. A reação inflamatória tecidual foi avaliada em 2h, 24h e 14 dias após as injeções e as amostras foram qualitativamente analisadas em microscópio óptico. Análise estatística foi realizada utilizando teste ANOVA e post hoc de Tukey para testes in vitro e Kruskal‐Wallis e post hoc de Dunn para o teste in vivo (α=.05). Resultados: No ensaio de “scratch”, Ca(OCl)2 não apresentou diferença estatística em relação ao controle no período de 24h (p<0.05). NaOCl e Ca(OCl)2 a 0.0075% e 0.005% apresentaram resultados de viabilidade similar ao grupo controle positivo (p > 0.05) no ensaio Azul de Trypan. No teste in vivo, Ca(OCl)2 1% mostrou uma diminuição significativa de neutrófilos entre 2h e 24h (p=0.041) e entre 2h e 14d (p=0.017). Não houve diferença estatística entre os grupos para linfócitos/plasmócitos e macrófagos. Conclusão: Ca(OCl)2 mostrou resultados favoráveis de viabilidade e induziu um baixo nível de resposta inflamatória tecidual, apresentando, assim, citotoxicidade e biocompatibilidade aceitáveis para uma solução irrigadora. / Introduction: The aim of the present study was to analyze cytotoxicity in vitro on cultured 3T3 fibroblasts and inflammatory tissue reaction in vivo on rats to calcium hypochlorite (Ca(OCl)2) solutions compared with sodium hypochlorite (NaOCl) solutions. Methods: Cultured 3T3 fibroblasts were exposed to different concentrations of calcium and sodium hypochlorite and a scratch assay was performed. The viability rate was analyzed with Trypan Blue assay. A. The 1 and 2.5% solutions were still injected into the subcutaneous tissues of eighteen male Wistar rats aged 18 weeks. Inflammatory tissue reaction was evaluated at 2h, 24h and 14 days after the injections and the samples were qualitatively analyzed through a light microscope. Statistical analysis was assessed by ANOVA and Tukey post hoc test for in vitro assays and by Kruskal-­‐Wallis and Dunn post hoc test for in vivo assay (α=.05). Results: In scratch assay, Ca(OCl)2 showed no statistically significant difference to control group at 24h (p<0.05). 0.0075% and 0.005% NaOCl and Ca(OCl)2 presented results similar to positive control group (p > 0.05) on Trypan Blue assay. In in vivo assay, 1% calcium hypochlorite group showed a significant decrease of neutrophils at 2h and 24h (p=0.041) and 2h and 14d (p=0.017). There was no statistically significant difference for lymphocytes/plasmocytes and macrophages among groups. Conclusions: Ca(OCl)2 showed favorable results of viability and induced an low level of inflammatory response, thus presenting an acceptable cytotoxicity and biocompatibility for an irrigant solution.
105

Biocompatibilidade dos cimentos Sealer 26 e óxido de zinco e eugenol protegidos ou não com dois diferentes tipos de própolis: análise em tecido subcutâneo de ratos / Sealer 26 and zinc-oxide-eugenol sealer biocompatibility either sheltered or not with two different sorts of propolis: rat subcutaneous tissue analyzes

Fernanda Gomes de Moraes 06 October 2006 (has links)
O objetivo deste trabalho foi avaliar a intensidade das reações inflamatórias do tecido conjuntivo subcutâneo de ratos, ao implante dos cimentos Sealer 26 e óxido de zinco e eugenol protegidos ou não com 2 diferentes tipos de própolis. Foram utilizados 39 ratos, nos quais, após anestesia geral e tricotomia da região dorsal foram realizadas duas incisões longitudinais. Após divulsão do tecido subcutâneo , foram implantados 3 tubos de polietileno, sendo 2 na região anterior 1 na região posterior, com uma distância de 5 cm entre eles. Cinquenta e quatro tubos foram preenchidos com cimento de óxido de zinco e eugenol consistente. Desses 54 tubos, 36 sofreram aplicação de própolis em suas extremidades recobrindo a área do cimento. Em 18, foi aplicada a própolis BRP1 e nos restantes a própolis MAR.Os demais tubos não sofreram tratamento nas extremidades. Outros 54 tubos foram preenchidos com Sealer 26, também consistente. Identicamente aos do grupo anterior, 36 deles tiveram as extremidades recobertas com própolis sendo metade com a própolis BRP1 e a outra com a própolis MAR. Os outros 18 não receberam aplicação da própolis. Os períodos experimentais foram de 7, 30 e 60 dias com 13 animais em cada período, sendo 12 com 3 tubos com os materiaisexperimentais e um que foi usado como controle, a que recebeu 4 tubos, 2 com guta-percha e 2 vazios. Após a morte dos animais, preparo das peças e obtenção dos cortes foram analisados os eventos microscópicos estipulando escores a cadasituação apresentada. A aplicação das própolis recobrindo os cimentos não alterou o comportamento dos mesmos, a própolis tipo MAR mostrou resultados mais favoráveis do que a BRP1, porém, sem diferença estatística significante entre elas, o óxido de zinco e eugenol apresentou melhor comportamento biológico do que o Sealer 26. Os cimentos quando permaneceram nos tubos comportaram se melhor do que quando extravasados. / This research aims to evaluate the intensity of inflammatory reaction in conjunctive subcutaneous tissue of rats to the sealer 26 and zinc-oxide-eugenol either sheltered or not with two different sorts of propolis. Two incisions were performed in 39 rats after anesthesia and trichotomy of the dorsal region. Three polyethylene tubes were implanted within five centimeters from each other. Fifty-four tubes were filled with zinc-oxide-eugenol sealer consistently. Thirty-six out of these fifty-four tubes were also spread with propolis in their borders sheltering the sealer area. The BRP1 propolis was sheltered in eighteen of them and MAR propolis was spread on the remaining tubes. The other tubes were not spread on their borders. Other fifty-four tubes were also filled with Sealer 26 consistently. Like the other group, thirty-six tubes were covered with propolis in their borders where half BRP1 propolis was used and the remaining tubes were covered with MAR propolis. The other eighteen tubes were not spread on their borders. The experimental periods were 7, 30 and 60 days with thirteen animals in each period which twelve animals had three tubes with experimental materials and one animal had four tubes which two tubes were filled with gutta-percha and two empty tubes considered as a control group. After the animals\' death, biopsy was performed removing the tubes. The tissues were prepared histologically and after obtaining the cut off, these were analyzed to the microscopic events specifying score. The application of propolis covering the sealers did not change their behavior. MAR propolis showed better results than the BRP1 propolis, notwithstanding they showed no statistic significant difference. Zinc-oxide-eugenol showed a better biologic behavior than Sealer 26. Both sealers behaved better when kept in the tubes than then they spilled out.
106

Migração celular, viabilidade e reação tecidual de soluções irrigadoras à base de hipoclorito de cálcio : estudo in vitro e in vivo / Cell migration, viability and tissue reaction of calcium hypochlorite based‐solutions irrigants : an in vitro and in vivo study

Blattes, Gabriela Bess Ferraz January 2015 (has links)
Introdução: O objetivo do presente estudo foi analisar a citotoxicidade e biocompatibilidade de soluções de hipoclorito de cálcio (Ca(OCl)2) comparadas a soluções de hipoclorito de sódio (NaOCl) in vitro em cultura de fibroblastos 3T3 e in vivo em ratos. Metodologia: Culturas de fibroblastos 3T3 foram expostas a diferentes concentrações de hipoclorito de cálcio e sódio e foi realizado um ensaio de “scratch”. Além disso, a taxa de viabilidade foi analisada utilizando o teste Azul de Trypan. As soluções a 1 e 2,5% foram, também, injetadas no tecido conjuntivo de 18 ratos Wistar de 18 semanas de idade. A reação inflamatória tecidual foi avaliada em 2h, 24h e 14 dias após as injeções e as amostras foram qualitativamente analisadas em microscópio óptico. Análise estatística foi realizada utilizando teste ANOVA e post hoc de Tukey para testes in vitro e Kruskal‐Wallis e post hoc de Dunn para o teste in vivo (α=.05). Resultados: No ensaio de “scratch”, Ca(OCl)2 não apresentou diferença estatística em relação ao controle no período de 24h (p<0.05). NaOCl e Ca(OCl)2 a 0.0075% e 0.005% apresentaram resultados de viabilidade similar ao grupo controle positivo (p > 0.05) no ensaio Azul de Trypan. No teste in vivo, Ca(OCl)2 1% mostrou uma diminuição significativa de neutrófilos entre 2h e 24h (p=0.041) e entre 2h e 14d (p=0.017). Não houve diferença estatística entre os grupos para linfócitos/plasmócitos e macrófagos. Conclusão: Ca(OCl)2 mostrou resultados favoráveis de viabilidade e induziu um baixo nível de resposta inflamatória tecidual, apresentando, assim, citotoxicidade e biocompatibilidade aceitáveis para uma solução irrigadora. / Introduction: The aim of the present study was to analyze cytotoxicity in vitro on cultured 3T3 fibroblasts and inflammatory tissue reaction in vivo on rats to calcium hypochlorite (Ca(OCl)2) solutions compared with sodium hypochlorite (NaOCl) solutions. Methods: Cultured 3T3 fibroblasts were exposed to different concentrations of calcium and sodium hypochlorite and a scratch assay was performed. The viability rate was analyzed with Trypan Blue assay. A. The 1 and 2.5% solutions were still injected into the subcutaneous tissues of eighteen male Wistar rats aged 18 weeks. Inflammatory tissue reaction was evaluated at 2h, 24h and 14 days after the injections and the samples were qualitatively analyzed through a light microscope. Statistical analysis was assessed by ANOVA and Tukey post hoc test for in vitro assays and by Kruskal-­‐Wallis and Dunn post hoc test for in vivo assay (α=.05). Results: In scratch assay, Ca(OCl)2 showed no statistically significant difference to control group at 24h (p<0.05). 0.0075% and 0.005% NaOCl and Ca(OCl)2 presented results similar to positive control group (p > 0.05) on Trypan Blue assay. In in vivo assay, 1% calcium hypochlorite group showed a significant decrease of neutrophils at 2h and 24h (p=0.041) and 2h and 14d (p=0.017). There was no statistically significant difference for lymphocytes/plasmocytes and macrophages among groups. Conclusions: Ca(OCl)2 showed favorable results of viability and induced an low level of inflammatory response, thus presenting an acceptable cytotoxicity and biocompatibility for an irrigant solution.
107

Avaliação do comportamento biológico do cimento endodôntico MTA Fillapex em tecido ósseo de ratos / Evaluation of rat bone tissue response to MTA Fillapex

Assmann, Eloísa January 2013 (has links)
Introdução: A biocompatibilidade é uma propriedade importante e necessária a um cimento endodôntico. O objetivo do presente estudo foi fazer uma análise microscópica das reações do tecido ósseo do fêmur de ratos da linhagem Wistar frente ao cimento MTA Fillapex, comparando-as ao cimento AH Plus e ao grupo controle (cavidade vazia), nos períodos de 7, 30 e 90 dias. Materiais e Métodos: Foram utilizados 18 animais, divididos em 3 grupos, de acordo com o período experimental (n=6). Três cavidades foram preparadas no fêmur da pata traseira direita de cada animal, sendo que uma foi preenchida com AH Plus, a outra com MTA Fillapex e a última permaneceu vazia (controle negativo). Decorridos os períodos experimentais, os ratos foram mortos e as patas removidas, dissecadas e preparadas para análise histológica. Os cortes foram analisados em microscópico óptico. O infiltrado inflamatório e as zonas de calcificação foram avaliados de forma dicotômica (presente ou ausente). A formação de barreira óssea foi classificada como ausente, parcial ou completa. Testes estatísticos não-paramétricos foram utilizados para a comparação dos dados (p<0,05). Resultados: As comparações entre os períodos experimentais mostraram que aos 7 dias todos os grupos apresentaram menor formação de barreira óssea e que o MTA Fillapex apresentou mais áreas de calcificação em relação aos demais períodos. Nos grupos do AH Plus e do MTA Fillapex, o infiltrado inflamatório reduziu significativamente aos 90 dias. As comparações entre os grupos mostraram mais áreas de calcificação no grupo do AH Plus aos 30 e 90 dias. O grupo controle apresentou menos infiltrado inflamatório aos 30 dias. Não houve diferença significativa entre os grupos na formação de barreira óssea. Conclusões: O cimento endodôntico MTA Fillapex apresentou comportamento biológico satisfatório em contato direto com tecido ósseo de rato. As características do reparo foram semelhantes às do cimento AH Plus, porém o MTA Fillapex não induziu a formação de áreas de calcificação na medula óssea. / Introduction: Biocompatibility is an important property required for a endodontic sealer. This study aimed to analyze bone tissue reactions to MTA Fillapex compared to an epoxy resin-based material in the femur of Wistar rats. Methods: Bone tissue reactions were evaluated in 18 animals after 7, 30 and 90 days (n=6 per period). Three surgical cavities were prepared on femur and filled with 0.1 mL of AH Plus, MTA Fillapex or no sealer (negative control). By the end of each experimental period, six animals were randomly euthanized, the femur was dissected and the surgical cavities separated. The samples were histologically processed and analyzed by light microscope. Inflammatory infiltrate and the calcification zones were evaluated dichotomously; hard tissue barrier was classified as absent, partial or full. Results: Comparison among periods showed that at 7 days all groups presented less hard tissue barrier and MTA Fillapex showed more calcification zones than in other periods. The inflammatory infiltrate significantly reduced at 90 days in AH Plus and MTA Fillapex groups. Comparisons among the groups presented more calcification zones for AH Plus than for the other groups at 30 and 90 days. Control group showed less inflammatory infiltrate at 30 days. There were no singificant diferences to hard tissue barrier among the groups. Data were analyzed by non-parameric tests. Significance level was preset in 0.05. Conclusions: MTA Fillapex presented satisfactory biological behaviour when in direct contact with rat bone tissue. The repair characteristics were similar to those produced by AH Plus, but MTA Fillapex doesn’t induce mineralization in the bone marrow.
108

Modificação de superfície empregando-se laser e recobrimento de implantes dentários de titânio com apatitas

BRAGA, FRANCISCO J.C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:53:13Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:37Z (GMT). No. of bitstreams: 1 11663.pdf: 10292078 bytes, checksum: 0f5eba7b9211550254ba580ec5d5f63d (MD5) / Tese (Doutoramento) / IPEN/T / Universidade Estadual Paulista, Instituto de Quimica, Campus de Araraquara
109

Desenvolvimento, caracterização e estudo pré-clínico de dispositivos implantáveis biocompatíveis baseados no polímero poli(?-caprolactona) / Development, characterization and preclinical evaluation of the implantable biocompatible prototypes based on poli(?-caprolactona)

SILVA, FABIANA M. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:33:51Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:59Z (GMT). No. of bitstreams: 1 16497.pdf: 92708 bytes, checksum: 7ccf16810b03dfc8aa4c309390f8b21a (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
110

Pesquisa e desenvolvimento de biomateriais: estudo das inter-relações científicas, tecnológicas e normativas / Research and development of biomaterials: study of scientific, tecnological and regulatory inter relationship

BORELLI, VANESSA 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:33:31Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:05:34Z (GMT). No. of bitstreams: 0 / A história da pesquisa e desenvolvimento dos biomateriais e dispositivos médicos mostra a inserção de produtos não seguros no mercado, os quais foram causa de mortes e seqüelas nos pacientes. Diante de tal quadro, pode-se dizer que diversos setores da indústria, representantes da academia, assim como órgãos governamentais de regulamentação e controle da qualidade de produtos, estão sob crescente pressão para educação e integração do setor. Sob esta perspectiva, a pesquisa passou a ser um diagnóstico das interrelações inseridas em tal cenário. Este trabalho foi realizado por meio de pesquisa etnográfica entre agosto de 2008 e agosto de 2010 com o intuito de reconhecer e analisar as inter-relações científicas, tecnológicas e normativas na pesquisa dos biomaterias. Neste percurso utilizamos a Norma ISO 10.993, que trata das avaliações biológicas dos biomateriais, para aproximação com os grupos de pesquisa. A pesquisa de campo envolveu: 1. Observação das práticas laboratoriais e acompanhamento de duas disciplinas de pós-graduação oferecidas no IPEN/SP: Introdução aos Biomateriais (TNM5782) e Biomateriais Propriedades e Avaliação (TNM 5783); 2. Participação nos Congressos Latino Americano de Órgãos Artificiais e Biomateriais (COLAOB) e nos eventos promovidos pelo Instituto Nacional de Ciência e Tecnologia (INCT) Biofabris; e, 3. Organização de um Debate com os grupos de pesquisa em biomateriais do IPEN. O debate e as aulas foram filmados, transcritos e analisados. Os resultados apontaram os grandes avanços dos programas acadêmicos de biomaterais e da integração entre as diversas 18 formações que trabalham nesta linha de pesquisa. Em termos de aplicação tecnológica, o envolvimento dos pesquisadores com os aspectos industriais e regulatórios tornou-se presente no cotidiano acadêmico. Assim, foi ressaltada a importância das aproximações entre a pesquisa e ensino e estas outras esferas e discutida as possibilidades de inserção de assuntos políticos, sociais, culturais e organizacionais neste contexto. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.0949 seconds