• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 363
  • 40
  • 40
  • 39
  • 39
  • 24
  • 16
  • 15
  • 9
  • 6
  • 6
  • 6
  • 1
  • 1
  • Tagged with
  • 388
  • 314
  • 99
  • 90
  • 56
  • 46
  • 41
  • 40
  • 39
  • 37
  • 35
  • 35
  • 34
  • 33
  • 32
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Avaliação da biocompatibilidade e do processo de reparo dos cimentos endodônticos: MTA Fillapex, Endo-CPM-Sealer e Sealapex

Watanabe, Simone [UNESP] 05 April 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:13Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-04-05Bitstream added on 2014-06-13T21:07:35Z : No. of bitstreams: 1 watanabe_s_dr_araca.pdf: 1959528 bytes, checksum: 1744de13ccd7ec1e15e0ab0dbd88c788 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo deste estudo foi avaliar a resposta tecidual frente ao implante de tubos de polietileno preenchidos pelos cimentos Sealapex®, Endo-CPM-Sealer® e MTA Fillapex® em tecido subcutâneo de ratos, bem como avaliar o processo de reparo de dentes de cães com lesão periapical, obtida experimentalmente, obturados com os mesmos cimentos. Para o teste de biocompatibilidade foram utilizados 30 ratos, os quais receberam individualmente três implantes de tubos de polietileno contendo os cimentos a serem testados e mais um tubo vazio como controle. Os períodos de avaliação foram de 7, 15, 30, 60 e 90 dias. Os espécimes foram processados laboratorialmente e analisados nas colorações de Hematoxilina e Eosina, Von Kossa e sem coloração para análise sob luz polarizada. Foram atribuídos escores e os dados obtidos foram analisados pelo teste Kruskal Wallis. Todos os materiais causaram reações moderadas no tempo experimental de 7 dias. A resposta foi moderada e similar para o grupo controle no 15° dia com Sealapex® e Endo-CPM-Sealer®. O grupo MTA Fillapex® apresentou reações leves a partir do 15° dia. Mineralizações e granulações brirrefringentes à luz polarizada foram observadas com todos os materiais. Foi possível concluir que todos os materiais testados apresentaram resultados similares, sendo considerados biocompatíveis e estimulantes de mineralização. Para a avaliação do processo de reparo de dentes de cães com lesão periapical, obtida experimentalmente, foram empregados 62 canais radiculares de 2 cães machos da raça Beagle. Os animais foram anestesiados, as polpas foram extirpadas e os canais ficaram expostos ao meio oral para o desenvolvimento de lesões periapicais. Após 6 meses os dentes foram tratados endodonticamente e foram divididos em 5 grupos experimentais... / The aim of this study was to evaluate the tissue response to implanted polyethylene tubes filled with Sealapex®, Endo-CPM-Sealer® and MTA Fillapex® in rat subcutaneous tissue, and to evaluate the healing process of dogs' teeth with experimental periapical lesions filled with the same sealers. For the biocompatibility test, it were used thirty rats, which received three individual implants of polyethylene tubes containing the sealers to be tested and an empty tube as control. Evaluations periods were on 7, 15, 30, 60 and 90 days. The specimens were laboratory processed and analyzed in Hematoxylin and Eosin, Von Kossa and without staining for polarized light. Scores were assigned and data were analyzed by Kruskal Wallis test. Both materials caused mild to moderate reactions on 7 days. The response was moderate and similar to the control at the 15th day with Sealapex® and Endo-CPM-Sealer®. MTA Fillapex® evoked mild reactions from the 15th day on. Mineralization and granulations birefringent to the polarized light were observed with all materials. It was possible to conclude that all materials tested showed similar results and they are considered biocompatible and stimulating mineralization. For the evaluation of the healing process of dogs' teeth with periapical lesions, sixty-two roots canals of two male beagle dogs were used. The animals were anesthetized, pulpectomy were performed and the canals remained open and exposed to the oral environment to induce a periapical lesion. After 6 months the teeth were endodontically treated and divided into 5 experimental groups, according to the filling material: Group I Sealapex®; Group II – Endo-CPM-Sealer®; Group III – MTA Fillapex®; Group IV – positive control; Group V – negative control. After 180 days, the animals were killed, the specimens were removed... (Complete abstract click electronic access below)
62

Efeito de elementos susbstitucionais e intersticiais nas propriedades mecânicas e na biocompatibilidade de ligas do sistema Ti-15Zr-xMo / Effect of substitutional and interstitial elements in the mechanical properties and biocompatibility of Ti-15Zr-xMo system alloys

Correa, Diego Rafael Nespeque [UNESP] 30 March 2015 (has links) (PDF)
Made available in DSpace on 2015-08-20T17:10:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-03-30. Added 1 bitstream(s) on 2015-08-20T17:27:01Z : No. of bitstreams: 1 000842011.pdf: 9116048 bytes, checksum: 1af1dd19206b525a42f2d99d07002ca8 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Titânio e suas ligas são utilizados na área biomédica principalmente como implantes cardiovasculares, ortopédicos e dentários, devido à elevada razão resistência mecânica e densidade, baixo módulo de elasticidade, excelente resistência à corrosão e ao desgaste, além de comprovada biocompatibilidade. O zircônio apresenta propriedades químicas semelhantes ao tiânio, podendo melhorar a resistência mecânica e de corrosão.O molibdênio é um forte β-estabilizador, que pode diminuir o módulo de elasticidade e melhorar a resistência à corrosão. Neste trabalho foram analisados os efeitos dos elementos de liga e tratamentos termomecânicos em ligas de Ti-15Zr-xMo (x= 5, 15 e 20 %p), visando aplicações biomédicas. A qualidade das amostras foi avaliada por espectrometria óptica, EDS, mapeamento químico e medidas de densidade. A caracterização estrutural foi obtida por medidas de DRX e análise pelo método de Rietveld. A caracterização microestrutural foi realizada por MO, MEV e MET. As propriedades mecânicas foram analisadas por medidas de microdureza Vickers e módulo de elasticidade. As caracterizações químicas indicaram uma boa qualidade das ligas para o estudo. A caracterização estrutural indicou uma estrutura cristalina com fases a+β para a liga Ti-15Zr-5Mo, fase β metaestável para a liga Ti-15Zr-10Mo, e fase β para Ti-15Zr-15Mo e Ti-15Zr-20Mo. A caracterização microestrutural exibiu a formação da fase a na forma de estruturas aciculares finas e a fase β como grãos equiaxiais. A análise mecânica indicou que a dureza e o módulo de elasticidade das ligas foram sensíveis à concentração de molibdênio. A microestrutura e propriedades mecânicas analisadas apresentaram também dependências do teor de oxigênio intersticial, além disso, os tratamentos termomecânicos possibilitaram a alteração da microestrutura das ligas significativamente. Não foram observados efeitos citotóxicos em nenhuma... / Titanium and its alloys are used in the biomedical area primarily as cardiovascular, orthopedic and dental implants, due to the high mechanical resistance and density ratio, low modulus of elasticity, excellent corrosion and wear resistance, plus proven biocompatibility. The zirconium presents similar chemical properties to titanium, and can improve the mechanical and corrosion resistance. Molybdenum is a strong β-stabilizer, which can decrease the modulus of elasticity and improve corrosion resistance. In this work we analyzed the effects of alloying elements and thermomechanical treatments in Ti-15Zr-xMo (x= 5, 10, 15 and 20 wt%) alloys, aiming at biomedical applications. The quality of the samples was evaluated by optical spectrometry, EDS, chemical mapping and density measurements. The structural characterization was obtained by DRX measurments and analysis by the Rietveld's method. The microstructural characterization was performed by OM, SEM and TEM. The mechanical properties were analyzed by measures of Vickers microhardness and modulus of elasticity. The chemical characterizations indicate a good quality of alloys for the study. The structural characterization indicated a crystalline structure with a+β phases for Ti-15Zr-5Mo alloy, mestable β phase for Ti-15Zr-10Mo alloy, and β phase for Ti-15Zr-15Zr and Ti-15Mo-20Mo alloys. The microstructural characterization exhibited the formation of a phase in the form of fine acicular structures and β phase as equiaxial grains. The mechanical analysis indicated that the hardness and modulus of elasticity of the alloys were sensitive to the concentration of molybdenum. The microstructure and mechanical properties were analyzed also with interstitical oxygen dependence, moreover, the thermomechanical treatments change significantly the microstructure of alloys. Cytotoxic effects were not observed in any of the studied alloys. The Ti-15Zr-15Mo presented better mechanical compatibility and... / FAPESP: 2010/20440-7
63

Caracterização e avaliação da citocompatibilidade de nanocompositos baseados em celulose bacteriana e fibroína para aplicação em regenração tecidual

Barud, Hélida Gomes de Oliveira [UNESP] 17 March 2014 (has links) (PDF)
Made available in DSpace on 2014-12-02T11:16:36Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-03-17Bitstream added on 2014-12-02T11:21:11Z : No. of bitstreams: 1 000800651.pdf: 2977752 bytes, checksum: 092cc7fa32e70c8eafda726bb4d3972f (MD5) / A engenharia de tecidos tem como perspectiva desenvolver opções terapêuticas para quadros clínicos com prognóstico limitado, objetivando substituir ou regenerar os tecidos lesados por meio do uso de biomateriais. A metodologia baseia-se no cultivo de células sobre uma matriz ou scaffold que deve ser otimizado para minimizar o risco de infecções e permitir a liberação das moléculas bioativas no local pretendido. As propriedades dos diversos biomateriais são essenciais para o sucesso da metodologia e estes podem ser manipulados de forma a mimetizar a arquitetura da matriz nativa. Assim, nos propomos a desenvolver um novo biocompósito baseado em celulose bacteriana (CB)/ fibroína (FB) visando aplicações em regeneração tecidual na odontologia, em 3 concentrações diferentes (CB/FB25%, CB/FB50% e CB/FB75%). Estes foram caracterizados por análise termogravimétrica, Espectroscopia Vibracional na Região do Infravermelho (FT-IR), Difração de Raios-X, e Microscopia Eletrônica de Varredura (MEV), demonstrando boa estabilidade físico-química, inclusive resitência à degradação térmica em altas temperaturas. A investigação da citocompatibilidade foi conduzida por meio de testes in vitro apenas com as amostras de CB/FB50%. Os testes aplicados foram MTT, azul de tripano, adesão e proliferação celular. As análises estatísticas foram realizadas por meio do software Graph Prism 5.0. Os resultados demonstraram que o material desenvolvido é biocompatível e não citotóxico. As imagens de MEV revelaram um número muito maior de células aderidas à superfície dos scaffolds de CB/FB quando comparado ao de CB pura. Com base nos dados obtidos é possível sugerir que o nanocompósito baseados em CB/FB50% configura uma excelente alternativa como scaffold para a reparação de tecidos. / Tissue engineering has the purpose of developping therapeutic options especially designed to be used on limited clinical conditions, aiming to replace or regenerate damaged tissues applying biomaterials for that. The method is based on the cultivation of cells on a matrix or scaffold that should be optimized to offer minimum risk of infections and allow the release of bioactive molecules at the desired location. The success of the methodology depends on Biomaterials’ properties that can be manipulated to mimic the three-dimensional architecture of native tissues extracellular matrix. Thus, we purpose to prepare a new nanocomposite based on bacterial cellulose (BC) / fibroin (SF) aiming at applications in the process of tissue regeneration in dentistry. Three different material’s compositions were prepared (BC/SF 25 % BC/SF 50 % and BC/SF 75 %) and all of them were characterized by thermogravimetric analysis, Vibrational Spectroscopy in the Infrared Region (FT-IR), X-ray diffraction, and Scanning Electron Microscopy (SEM). The material showed good physical and chemical stability including resistance to thermal degradation at high temperatures. The investigation of the cytocompatibility was realized just using the samples BC/SF 50 % and the in vitro tests conducted were MTT, Trypan Blue, cell adhesion and proliferation assays. The statistical analysis was done applying the software Graph Pad Prism 5.0. The results showed that the developed nanocomposite is biocompatible and non-cytotoxic. SEM images revealed a greater number of cells attached to the scaffold CB / FB surface when compared to pure CB scaffolds. Based on the data obtained, it is possible to suggest that the nanocomposite based on CB/FB50% configures an excellent alternative as a scaffold for tissue repair.
64

Avaliação de compósitos á base de celulose bacteriana-hidroxiapatita com peptídeo osteogênico para reparação óssea

Pigossi, Suzane Cristina [UNESP] 21 March 2014 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:23Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-03-21Bitstream added on 2015-01-26T13:30:33Z : No. of bitstreams: 1 000805886_20170321.pdf: 904849 bytes, checksum: bc7eee77a67bdd5dace720df7c69c6af (MD5) Bitstreams deleted on 2017-03-24T12:04:45Z: 000805886_20170321.pdf,. Added 1 bitstream(s) on 2017-03-24T12:05:38Z : No. of bitstreams: 1 000805886.pdf: 3705623 bytes, checksum: 006ac442bc6b4e331914cbe0aa6ab961 (MD5) / A celulose bacteriana (CB) é um biopolímero sob a forma de hidrogel nanoestruturado, o qual é uma excelente matriz para incorporação de outros compostos, e nos últimos anos a CB tem demonstrado resultados promissores para reparação tecidual. Além disso, compósitos baseados em CB e hidroxiapatita (CB-HA) são osteocondutores, e quando este compósito associado a peptídeos como OGP (osteogenic growth peptide) e a sua sequência C-terminal o pentapeptídeo OGP(10-14) poderão proporcionar-lhe propriedade osteoindutora. O presente estudo avaliou os compósitos CB-HA associados ou não a estes peptídeos para reparação óssea de defeitos críticos em calvária de camundongos. Os grupos experimentais avaliados foram CB-HA, CB-HA OGP, CB-HA OGP(10-14) e controle, nos respectivos períodos de análise: 3, 7, 15, 30, 60 e 90 dias. Após 3 dias de pós-operatório, as membranas CB-HA OGP e CB-HA OGP(10-14) promoveram maiores níveis de expressão dos principais genes marcadores de formação óssea. Além disso, após 7 dias foi observado na análise histomorfométrica que as membranas CB-HA e CB-HA OGP(10-14) promoveram maior neoformação óssea. Semelhantemente, essas membranas apresentaram maiores porcentagens de neoformação óssea como foi observado na microtomografia computadorizada nos períodos de 60 e 90 dias. Maiores níveis de expressão de alguns biomarcadores ósseos, como Alpl, Spp1 e Tnfrsf11b também foram observados para as mesmas membranas em 60 e 90 dias de pós-operatório. Conclui-se que os materiais CB-HA e CB-HA OGP(10-14) apresentaram melhor potencial na reparação óssea em defeitos críticos em calvária de camundongos, destacando o papel osteoindutor nos períodos iniciais de formação óssea da membrana de CB-HA OGP (10-14). / Bacterial cellulose (BC) is a biopolymer in the form nanostructured hydrogel, which is an excellent matrix for the incorporation of others compounds, and at last years, BC has demonstrated promising results for tissue repair. In addition, composites based on BC and hydroxyapatite (BC-HA) is osteoconductor; and when this BC-HA composite associated with the osteogenic growth peptide (OGP) or its C-terminal sequence the pentapeptide OGP (10-14) could be provide osteoinductive properties. This study aimed to evaluate the potential of BC-HA composites with or without OGP and OGP (10-14) in bone repair in critical-size calvarial defect in mice. The analyzed experimental groups were BC-HA, BC-HA-OGP, BC-HA-OGP (10-14) and control group in the respective periods: 3, 7, 15, 30, 60 and 90 days of postoperative. After 3 days of postoperative, bone biomarkers were upregulated mainly by BC-HA OGP and BC-HA OGP (10-14) membranes. In addition, a higher new bone formation was observed in the histomorphometric analysis for BC-HA and BC-HA OGP (10-14) membranes 7 days of postoperative. Similarly, in 60 and 90 days, high percentage of bone formation could be observed in micro-computed tomography analysis for BC-HA and BC-HA OGP (10-14) membranes. High expression of some bone biomarkers, such as Alpl, Spp1 and Tnfrsf11b were also observed for the same membranes 60 and 90 days of postoperative in mice calvarial. In conclusion, the BC-HA and BC-HA OGP (10-14) membranes promoted a better bone formation in critical-size calvarial defects in mice, mainly the BC-HA OGP (10-14) nanocomposite in the early periods of bone repair.
65

Resposta tecidual induzida por Biodentine™e MTA Branco em subcutâneo de ratos

Fonseca, Tiago Silva da [UNESP] 14 March 2014 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-03-14Bitstream added on 2015-03-03T12:07:17Z : No. of bitstreams: 1 000806813_20170314.pdf: 723572 bytes, checksum: a1a64b15ace1bfeea4702e2af46b1328 (MD5) Bitstreams deleted on 2017-03-17T12:38:10Z: 000806813_20170314.pdf,. Added 1 bitstream(s) on 2017-03-17T12:39:10Z : No. of bitstreams: 1 000806813.pdf: 3961779 bytes, checksum: 134f6d96d64debccca8243b79f70742a (MD5) / BiodentineTM é um biomaterial à base de silicato de cálcio produzido, segundo o fabricante, com o intuito de apresentar propriedades físico-químicas e biológicas superiores ao MTA. Nosso objetivo foi avaliar a resposta tecidual promovida por BiodentineTM (BDT) e MTA Angelus Branco em subcutâneo de ratos. Foram utilizados ratos adultos distribuídos em 3 grupos (n=20/grupo), segundo o material preenchendo os tubos de polietileno implantados no subcutâneo: BDT, MTA e GC (controle, tubos vazios). Após 7, 15, 30 e 60 dias, os implantes e os tecidos adjacentes foram processados para parafina. Cortes longitudinais das cápsulas adjacentes aos implantes foram corados com H&E, tricrômico de Masson, Picrosirius e submetidos ao Alcian Blue (AB) e reações imuno-histoquímicas para IL-6 e FGF-1. Obteve-se a densidade numérica de células inflamatórias (CI), de células imunomarcadas para IL-6 e FGF-1 e de mastócitos AB-positivos, além da porcentagem de colágeno birrefringente. Os dados foram submetidos à ANOVA e teste Tukey (p?0,05). O número de CI e de células imunomarcadas para IL-6 e FGF-1 foi significantemente maior aos 7 dias em todos os grupos. Diferenças significantes no número de células IL-6-positivas não foram observadas entre BDT e MTA aos 30 e 60 dias; aos 60 dias, diferenças significantes no número de CI também não foram detectadas. O número de células FGF-1-positivas foi significantemente maior no grupo BDT em comparação ao grupo MTA, em todos os períodos. A densidade numérica de mastócitos e a porcentagem de colágeno aumentaram significantemente ao longo do tempo. Aos 60 dias, o número de mastócitos e o conteúdo de colágeno foram significantemente maiores nos grupos BDT e MTA, respectivamente. A redução significante do processo inflamatório, concomitante à redução na imunoexpressão para IL-6, indica que ambos os materiais são biocompatíveis. A acentuada imunoexpressão de FGF-1 aos 7 dias... / BiodentineTM is a new calcium silicate-based biomaterial which presents improved physicochemical and biological properties compared to MTA. The aim of this study was to evaluate the tissue reaction promoted by BiodentineTM (BDT) and MTA Angelus White in rat subcutaneous. Adult rats were distributed into 3 groups (n=20/group) according to the implanted materials: BDT, MTA or CG (Control group; empty tubes). After 7, 15, 30 and 60 days, the implants and adjacent tissues were fixed and embedded in paraffin. Longitudinal sections of the capsule adjacent to implants were stained with H&E, Masson’s trichrome, Picrosirius and submitted to Alcian Blue (AB). Immunohistochemical reactions for IL-6 and FGF-1 were also performed. The number of inflammatory cells (IC), IL-6 and FGF-1 immunolabeled cells, AB-positive mast cells as well as birefringent collagen percentage were obtained. Data were statistically analyzed by ANOVA and Tukey test (p?0.05). The number of IC and IL-6 and FGF-1 immunolabeled cells were significantly high at 7 days in all groups. At 30 and 60 days, significant differences in the number of IL-6-positive cells were not detected between BDT and MTA. At 60 days, statistical difference in the IC number was not observed between BDT and MTA groups. In all periods, the number of FGF-1-positive cells was significant higher in BDT group in comparison to MTA. The numerical density of mast cells and collagen percentage increased over time. At 60 days, mast cells number and collagen content were significantly high in BDT and MTA groups, respectively. A significant reduction of inflammatory process and IL-6 immunoexpression indicates that both materials are biocompatible. Intense FGF-1 immunoexpression at 7 days suggests that this factor may be responsible, at least in part, for fibroblast proliferation and subsequent collagen formation in the capsules. Since a strong correlation between mast cells number and collagen density was detected...
66

Desenvolvimento e caracterização de novas ligas contendo titânio, molibdênio e manganês, para aplicações biomédicas /

Lourenço, Mariana Luna. January 2018 (has links)
Orientador: Carlos Roberto Grandini / Banca: Maria Rosifini Alves Rezende / Banca: Valentim Adelino Ricardo Barão / Resumo: Com o aumento da população mundial, o crescimento dos acidentes de trânsito e o aumento da expectativa de vida crescem cada vez mais a necessidade do uso de implantes, dentários e ortopédicos. Pesquisadores vêm trabalhando para o aperfeiçoamento dos biomateriais utilizados, melhorando a funcionalidade e aumentando a vida útil no corpo humano. O módulo de Young das ligas já utilizadas é ainda cerca de 2 a 4 vezes maior que o do osso humano. A liga de titânio mais utilizada para aplicações biomédicas é a Ti-6Al-4V, porém, estudos anteriores mostraram que o vanádio causa reações alérgicas nos tecidos humanos e o alumínio tem sido associado com desordens neurológicas. Assim, novas ligas de titânio sem a presença desses elementos estão sendo desenvolvidas, geralmente com elementos β-estabilizadores, que diminuem o módulo de elasticidade. O manganês é um forte candidato como elemento de liga para o desenvolvimento de novas ligas de titânio do tipo β, em razão de sua abundância e baixa citotoxicidade. O objetivo deste trabalho foi preparar e caracterizar novas ligas do sistema Ti-Mo-Mn, visando aplicações biomédicas. As ligas foram projetadas utilizando as teorias do Orbital Molecular e do molibdênio equivalente, foram obtidas por fusão a arco e caracterizadas química, estrutural, microestrutural, mecânica, e citotoxicamente, com o propósito de melhor compreender a relação entre a microestrutura e propriedades da liga. As ligas estudadas Ti-10Mo-5Mn e Ti-15Mo-5Mo apresentaram valore... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: LOURENÇO, M.L. Development and c haracterization of n ew a lloys containing Titanium, Molybdenum and Manganese for b iomedical a pplications. 2018. 6 2 p. Dissertation (Master in M a terials Science and Tec h n o logy) UN ESP, Bauru (SP), 2018 . ABSTRACT With the increase of the world population, the growth of traffic accidents and the increase in life expectancy, the need for the use of implants, dental and orthopaedics, is growing more and more. Researchers have been wor king towards the improvement of the used biomaterials, improving the functionality and increasing the useful life in the human body. Young's modulus of the alloys already used is still about 2 to 4 times larger than the human bone. The most commonly used t itanium alloy for biomedical applications is Ti - 6Al - 4V, but previous studies have shown that vanadium causes allergic reactions in human tissues and aluminum has been associated with neurological disorders. Thus, new titanium alloys without the presence of these elements are being developed, usually with β - stabilizers, which diminish the elastic modulus. Manganese is a strong candidate as an alloy element for the development of new β - type titanium alloys, due to its abundance and low cytotoxicity. The aim of this work was to prepare and characterize new al loys of the Ti - Mo - Mn system, aiming at biomedical applications. The alloys were designed using the the molecular orbital and the equivalent molybdenum theories, were obtained by arc - melti... (Complete abstract click electronic access below) / Mestre
67

Dispositivo médico assistencial para análise de turbidez do líquido peritoneal dialisado

Ferreira, Nilson Eduardo 23 November 2017 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade Gama, Programa de Pós-Graduação em Engenharia Biomédica, 2017. / Submitted by Raquel Almeida (raquel.df13@gmail.com) on 2018-03-12T18:55:37Z No. of bitstreams: 1 2017_NilsonEduardoFerreira.pdf: 4461261 bytes, checksum: d32571f7d507ec75f4f75c659fb5af11 (MD5) / Rejected by Raquel Viana (raquelviana@bce.unb.br), reason: Bom dia, Por favor, adeque o campo Orientador. Atenciosamente on 2018-03-15T12:54:37Z (GMT) / Submitted by Raquel Almeida (raquel.df13@gmail.com) on 2018-03-15T15:57:02Z No. of bitstreams: 1 2017_NilsonEduardoFerreira.pdf: 4461261 bytes, checksum: d32571f7d507ec75f4f75c659fb5af11 (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-03-15T18:09:24Z (GMT) No. of bitstreams: 1 2017_NilsonEduardoFerreira.pdf: 4461261 bytes, checksum: d32571f7d507ec75f4f75c659fb5af11 (MD5) / Made available in DSpace on 2018-03-15T18:09:24Z (GMT). No. of bitstreams: 1 2017_NilsonEduardoFerreira.pdf: 4461261 bytes, checksum: d32571f7d507ec75f4f75c659fb5af11 (MD5) Previous issue date: 2018-03-15 / A diálise peritoneal é um tratamento renal substitutivo cuja principal característica é a manutenção da qualidade de vida dos pacientes. Somente no Brasil, um crescente número de doentes renais é elegível para essa terapia e o grande desafio dos profissionais de saúde é a manutenção desses pacientes o maior tempo possível no tratamento. Neste estudo, propomos um Equipamento Médico-Assistencial para auxiliar aos profissionais de saúde no controle e monitoramento de marcadores negativos, como infecções e alterações biológicas, por meio da leitura e análise da turbidez do líquido dialisado. Como processo metodológico da pesquisa, a imersão no conhecimento do perfil das pessoas portadoras de insuficiência renal, em diálise peritoneal, foi necessária principalmente na avaliação da capacidade funcional desses doentes em conviver com o problema renal e tangenciá-los com recursos e mecanismos tecnológicos. As variáveis estatísticas demonstraram que, com o passar do tempo, com as limitações próprias da idade e pela condição de saúde fragilizada, muitos pacientes carecem de um apoio mais eficiente na percepção de sinais indicativos sobre a qualidade do líquido dialisado, ou a turbidez. Inferiu-se nos testes de hipótese que não há qualquer impacto da capacidade funcional face à doença renal, mesmo em casos extremos, no uso de controle eletrônico da turbidez sendo realizada por um dispositivo com as características do proposto no estudo. Os resultados obtidos com o dispositivo, comparados com os métodos de análises padrão do líquido de infusão peritoneal, demonstraram que os valores de turbidez medidas pelo equipamento proposto permitem avaliar as condições de turbidez do líquido peritoneal dialisado com maior acurácia do que o método tradicional, por percepção meramente visual. Nas análises, por meio da observação da absorbância pela técnica da espectrofotometria por emissão de luz visível, o valor de absorbância obtido para a substância de infusão peritoneal foi em torno de 0,001; já a média obtida nas análises do líquido dialisado pós terapia foi em torno de 0,17. Esses dados evidenciam a capacidade do dispositivo desenvolvido, tanto na realização dos testes in vitro quanto nos testes in vivo, cujos valores médios ficaram em 0,010 e 0,27 respectivamente. O dispositivo eletrônico desenvolvido a partir de componentes eletrônicos de fácil aquisição, e contando com mecanismos auxiliares como software de análise, base de dados para armazenamento e consulta online pela Web, compreendem um conjunto de ferramentas capazes de promover maior segurança na avaliação da turbidez do líquido peritoneal dialisado, uma análise mais precisa em seus níveis periódicos e, principalmente, a troca de informação permanente entre paciente e profissional de saúde, minimizando a demora em tomadas de decisão em saúde face à turbidez do líquido peritoneal dialisado. / Peritoneal dialysis is a substitutive renal treatment whose main characteristic is the maintenance of patients’ quality of life. In Brazil alone, a growing number of kidney patients are eligible for this therapy and the major challenge for healthcare professionals is to maintain these patients as long as possible in treatment. In this study, we propose a Medical Assistance Kit to assist health professionals in the control and monitoring of negative markers, such as infections and biological changes, by reading and analyzing the turbidity of the dialysed liquid. As a methodological process of the research, immersion in the knowledge of the profile of people with renal impairment in peritoneal dialysis was necessary mainly in the evaluation of the functional capacity of these patients to live with the renal problem and tangentiate them with technological resources and mechanisms. Statistical variables have shown that, over time, with age limitations and poor health status, many patients lack a more efficient support in the perception of indicative signals on the quality of the dialysed liquid or turbidity. We inferred hypothesis tests that there is no impact of functional capacity against renal disease, even in extreme cases, in the use of electronic turbidity control being performed by a device with the characteristics proposed in the study. The results obtained with the device, compared with the standard methods of peritoneal infusion liquid analysis, showed that the turbidity values measured by the proposed equipment allow to evaluate the turbidity conditions of the dialyzed peritoneal fluid more accurately than the traditional method, merely visual perception. In the analyzes, by observing the absorbance by the visible light emission spectrophotometry technique, the absorbance value obtained for the peritoneal infusion substance was around 0.001; the mean value obtained in the analysis of the dialysed liquid after therapy was around 0.17. These data demonstrate the ability of the device developed in both the in vitro and in vivo tests whose mean values were 0.010 and 0.27 respectively. The electronic device developed from easy-to-acquire electronic components, and having ancillary mechanisms such as analysis software, database for online storage and consultation by Web, comprise a set of tools capable of promoting greater safety in the evaluation of the turbidity of the dialyzed peritoneal fluid, a more accurate analysis in its periodic levels and, mainly, the exchange of permanent information between patient and health professional, minimizing the delay in health decision making in the face of turbidity of the peritoneal fluid dialysed.
68

SECTEM: sistema baseado na web de especificação e comparação técnica de equipamentos médicos registrados na Agência Nacional de Vigilância Sanitária / TCSME : web based system for especification and technical comparison of medical equipment registered in the National Sanitary Vigilance Agency

Ramirez Filho, Walter Lima 04 July 2016 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade Gama, Programa de Pós-Graduação em Engenharia Biomédica, 2016. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2016-08-26T21:06:58Z No. of bitstreams: 1 2016_WalterLimaRamirezFilho.pdf: 2865892 bytes, checksum: 0104b5032eb6f6b501dabcb61af57049 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2016-09-20T20:25:50Z (GMT) No. of bitstreams: 1 2016_WalterLimaRamirezFilho.pdf: 2865892 bytes, checksum: 0104b5032eb6f6b501dabcb61af57049 (MD5) / Made available in DSpace on 2016-09-20T20:25:50Z (GMT). No. of bitstreams: 1 2016_WalterLimaRamirezFilho.pdf: 2865892 bytes, checksum: 0104b5032eb6f6b501dabcb61af57049 (MD5) / A criação de ferramentas computacionais para aperfeiçoar o cuidado em saúde e o atendimento à racionalização, sustentabilidade dos eventos clínicos, econômicos e sociais da saúde possibilita solucionar problemas decorrentes da má especificação na aquisição de Equipamentos Médicos (EMs) no contexto da saúde pública. No presente estudo foi proposto um Sistema de Especificação e Comparação Técnica de EMs (SECTEM) que auxilie profissionais técnicos da Engenharia Clínica (EC), Engenharia Biomédica, entre outros, em atender às solicitações clínicas, por meio da especificação técnica, em relação à compra de EMs para as Unidades de Saúde. Estimam-se, também neste trabalho, aspectos ainda não abordados pela literatura, quanto ao gerenciamento de tecnologias de saúde, à medida que se discutem os impactos qualitativos da saúde, quando lançado o processo de compra de EMs. O software foi elaborado pelo padrão Modelo, Visão e Controlador (MVC), isto é, em três camadas que permite o acompanhamento e a realização de vários pequenos ajustes durante o seu incremento. Os resultados evidenciaram que em meio à preocupação com o fator “cuidado de saúde”, assim como a efetividade da atuação de EMs, após a aquisição pelo parque tecnológico, a maioria (99%) dos achados científicos ainda é incipiente na proposição de uma ferramenta capaz de auxiliar na adequada condução das comparações e especificações efetuadas na atualidade. O SECTEM proposto foi capaz de empregar o indispensável conhecimento técnico para especificar e comparar as tecnologias de forma útil e simplificada para os profissionais de saúde. ________________________________________________________________________________________________ ABSTRACT / The creation of computational tools to improve health care and service rationalization, sustainability of clinical, economic and social events in healthcare allows solving problems arising from mismanagement in purchasing Medical Equipments (MEs) in the context of public health. In this work it was proposed a Technical Comparison System of MEs (TCSME) that helps technical professionals of Clinical Engineering (CE), Biomedical Engineering, among others, to meet clinical demands, through the technical specification, in relation to the purchase of MEs for Health Units. This work also estimates aspects not yet addressed by literature on the management of Health Technologies, as it discusses the qualitative impacts of health when launched the process of buying MEs. The results shows that amid concern with the "Health Care" factor, as well as with the effectiveness of MEs operation after its acquisition, the majority (99%) of scientific researchers are still incipient in proposing a tool which is able to help in the proper conduct of the comparisons and specifications made today. The proposed TCSME was able to apply the indispensable technical knowledge to specify and compare the technology in a simplified and useful way for healthcare professionals.
69

Desenvolvimento e avaliação de cimentos endodônticos à base de silicatos de cálcio /

Bronzel, Cristiane Lopes Zordan. January 2018 (has links)
Orientador: Juliane Maria Guerreiro Tanomaru / Resumo: Novos cimentos endodônticos à base de silicatos de cálcio são propostos na busca de materiais com potencial bioativo. Publicação 1: Desenvolvimento e avaliação físico-química de dois cimentos endodônticos experimentais compostos por silicato tricálcico, silicato dicálcico, fosfato de cálcio monobásico, hidróxido de cálcio, óxido de zircônio e tungstato de cálcio; manipulados com polietilenoglicol - Experimental 1 (EXP1) ou com polietilenoglicol e hidrogel de quitosana - Experimental 2 (EXP2). TotalFill BC sealer (TF) e AH Plus (AHP) foram usados para comparação. Tempo de presa, escoamento e radiopacidade foram avaliados com base nas normas ISO 6876. Avaliou-se pH por um pHmetro digital, nos períodos de 3 e 12 horas, 1, 7, 14 e 21 dias. Avaliou-se solubilidade pela perda de massa após imersão em água destilada por 7 e 30 dias. Os dados obtidos foram submetidos aos testes ANOVA e Tukey (α=0,05). EXP2 e EXP1 apresentaram maior tempo de presa (P<0,05). Radiopacidade e escoamento de EXP1 e EXP2 atendem às normas da ISO 6876. EXP1 apresentou radiopacidade semelhante à TF (P>0,05) e maior que EXP2 (P<0,05). EXP1 apresentou escoamento semelhante à AHP (P>0,05) e maior que EXP2 (P<0,05). EXP1 e EXP2 apresentaram maior solubilidade após 7 dias (P<0,05). Após 30 dias de imersão, solubilidade de EXP1 foi semelhante à TF (P>0,05). EXP1, EXP2 e TF apresentaram pH alcalino em todos os períodos experimentais. Conclui-se que EXP1 apresenta tempo de presa, radiopacidade, escoamento, solubilida... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: New calcium silicate-based endodontic cements are proposed in the search for materials with bioactive potential. Publication 1: Development and physical-chemical evaluation of two experimental endodontic cements composed of tricalcium silicate, dicalcium silicate, monobasic calcium phosphate, calcium hydroxide, zirconium oxide and calcium tungstate; handled with polyethylene glycol - Experimental 1 (EXP1) or with polyethylene glycol and chitosan hydrogel - Experimental 2 (EXP2). TotalFill BC sealer (TF) and AH Plus (AHP) were used for comparison. Setting time, flow and radiopacity were evaluated based on ISO 6876. pH was evaluated with a digital pH meter, in the periods 3 and 12 hours, 1, 7, 14 and 21 days. Solubility was evaluated by mass loss after immersion in distilled water for 7 and 30 days. Data were submitted to ANOVA and Tukey tests (α=0.05). EXP2 and EXP1 presented higher setting time (P<0.05). Radiopacity and flow of EXP 1 and EXP2 meet ISO 6876 standards. EXP1 presented radiopacity similar to TF (P>0.05) and higher than EXP2 (P<0.05). EXP1 presented similar flow to AHP (P>0.05) and higher than EXP2 (P<0.05). EXP1 and EXP2 presented higher solubility after 7 days (P<0.05). After 30 days of immersion, solubility of EXP1 was similar to TF (P>0.05). EXP1, EXP2 and TF presented alkaline pH in all experimental periods. It is concluded that EXP1 presents proper setting time, radiopacity, flow, solubility and pH, and it has potential for use as endodontic cement. Publicat... (Complete abstract click electronic access below) / Mestre
70

Obtenção e caracterização de filmes de PHB utilizando a técnica de solution blow spinning /

Sakamoto, Fabiana Carneiro. January 2013 (has links)
Orientador: José Antonio Malmonge / Banca: Adriana Campos Passanezi Sant'ana / Banca: Marcia Regina de Moura Aouada / Resumo: Membranas fibrosas de PHB foram obtidas através da técnica de fiação por sopro em solução (solution blow spinning) utilizando solução PHB/clorofórmio nas concentrações: 8%, 10% e 12% (m/v) e diferentes pressões do ar de arraste (P) tais como: 120, 140,160 e 200kPa. As taxas de injeção da solução (β) foram: 110,135 e 150μL/min. Pela análise de microscopia eletrônica de varredura (MEV) verificou-se que o diâmetro das fibras aumenta com o aumento da concentração de PHB na solução quando a taxa de injeção da solução e a pressão foram mantidas constantes. Este é o parâmetro que mais influencia a morfologia das fibras. O diâmetro médio dessas fibras variou em um intervalo de 0,5 - 1,7μm. Observou-se através da técnica de calorimetria exploratória diferencial (DSC) que houve um pequeno deslocamento dos picos referentes às temperaturas de fusão do PHB, no segundo aquecimento, para valores menores quando comparados com os picos do primeiro aquecimento em razão da degradação do PHB. Com o aumento da concentração da solução os valores das temperaturas de fusão do PHB são deslocados para valores menores. O grau de cristalinidade das membranas fibrosas aumenta ligeiramente com a diminuição da concentração, mas sem alterar sua estrutura cristalina. A porosidade mostrou ser dependente dos fatores analisados, porém a variável com maior influência é a concentração. A porosidade, também, é um bom indicador para a difusão da glicose através da membrana, mas não é determinante, já que não se pode indicar se existe interconectividade entre esses poros ou se uma manta densa é formada. Com o aumento da concentração, para uma dada pressão e vazão, há um aumento da porosidade e, conseqüentemente, da permeabilidade da glicose através da membrana que está relacionado ao aumento... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: PHB fibrous membranes were obtained by solution blow spinning technique using PHB/Chloroform solution with different concentrations such as; 8%, 10% and 12% (w/v), different air pressure (P) (120,140,160 and 200kPa) and different solution injection rate (β) (110, 135 and 150 μL/min). Evaluating scanning electron microscopy (SEM) images of PHB membranes it can observed that the diameter of the fibers increases with increasing concentration when air pressure and injection rate were kept constant. Fibers morphology is most affected by concentration. The mean diameter of these fibers obtained were in the range of 0.5 and 1.7 μm. DSC curves showed a displacement of melting temperature peak on second heating in comparison to the first heating peak due to PHB degradation. PHB membranes melting temperature decrease when solution concentration increases. Fibrous membranes cristallinity degree lightly increases when the concentration decrease, but there is no changing in the cristaline structure. All the analyzed factors affect porosity, however the concentration is the most important one. Porosity is also a good indicative of the diffusion of glucose though the membrane, although it is not determinant since it is not possible to conclude if exists interconectivity between pores. When air pressure and the solution injection rate were kept constant and concentration was increased, porosity was higher and diffusion coefficient was higher as well due to the increasing in fibers diameter. The higher permeability observed... (Complete abstract click electronic access below) / Mestre

Page generated in 0.08 seconds