461 |
AVALIAÇÃO CLÍNICA DA EFETIVIDADE E GENOTOXICIDADE DO PERÓXIDO DE CARBAMIDA 10% EM PACIENTES FUMANTES / Clinical evaluation of effectiveness and genotoxicity of 10% carbamide peroxide in smokersGeus, Juliana Larocca de 25 February 2014 (has links)
Made available in DSpace on 2017-07-24T19:22:31Z (GMT). No. of bitstreams: 1
Juliana Larocca Geus.pdf: 2198997 bytes, checksum: 8d29399aeb40e13ac3aa426797a08b0e (MD5)
Previous issue date: 2014-02-25 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study was to clinically evaluate the effectiveness, stability of color, dental sensitivity and genotoxicity of at-home bleaching with 10% carbamide peroxide (CP) in smokers and nonsmokers. For this study, two experiments were conducted. In Experiment 1 were selected 60 patients with central incisors A2 or darker, compared to Vita classical shade guide (Vita Zahnfabrik, Bad Säckingen, Germany), 30 smokers (S- experimental group) and 30 non-smokers (NS - control group). The bleaching was carried out with 10% CP (Whiteness Perfect, FGM, Joinville, Santa Catarina, Brazil) for a period of 3 hours daily for three weeks.The color was assessed by Vita classical (Vita Zahnfabrik, Bad Säckingen, Germany) and
spectrophotometer Vita Easyshade (Vita Zahnfabrik, Bad Säckingen, Germany) initially during bleaching (1st, 2nd and 3rd weeks) and after this procedure (1 week and 1 month). The tooth sensitivity was recorded by the patients, using a 0-4 scale and visual analogue scale
(VAS) of 10 cm. The Experiment 2 was conducted in the same sample of Experiment 1. The color was evaluated using Vita Bleachedguide 3D-MASTER (Vita Zahnfabrik, Bad Säckingen, Germany) in the same periods that Experiment 1. The genotoxicity of bleaching was evaluated by the frequency of micronuclei (MN) in the gingival tissue before and after
bleaching. Data from two experiments were evaluated by analysis of variance two-factor repeated measures and Tukey's test for contrast of means (α=0.05). Data from ΔSGU and ΔE showed an effectiveness of dental bleaching in both groups after three weeks of treatment.The prevalence of tooth sensitivity was similar between groups. The frequency of MN in the experimental group was significantly higher than in the control group regardless of bleaching treatment. It can be concluded that the effectiveness of bleaching and tooth sensitivity
resulting from the procedure does not seem to be affected by smoking and dental bleaching with 10% carbamide peroxide can be considered a safe procedure. / O objetivo deste estudo foi avaliar clinicamente a efetividade, estabilidade da cor, sensibilidade dental e genotoxicidade do clareamento caseiro com peróxido de carbamida (PC) 10% em pacientes fumantes e não fumantes. Para este estudo foram realizados dois experimentos. No Experimento 1 foram selecionados 60 pacientes com os incisivos centrais com cor A2 ou mais escuros, por comparação com a escala Vita classical (Vita Zahnfabrik, Bad Säckingen, Alemanha), sendo 30 fumantes (FU - grupo experimental) e 30 não fumantes
(NF - grupo controle). O clareamento dental foi realizado com PC 10% (Whiteness Perfect –FGM, Joinville, Santa Catarina, Brasil) pelo período de 3 h diariamente, durante três semanas.
A cor foi avaliada por meio da escala Vita classical e espectrofotômetro Vita Easyshade (Vita Zahnfabrik, Bad Säckingen, Alemanha), inicialmente, durante o clareamento dental (1ª, 2ª e 3ª semanas) e após este procedimento (1 semana e 1 mês). A sensibilidade dental foi registrada
pelos próprios pacientes, através da escala 0-4 e escala visual analógica (EVA) de 10 cm. O Experimento 2 foi realizado na mesma amostra do Experimento 1. A cor foi avaliada através da escala Vita Bleachedguide 3D-MASTER (Vita Zahnfabrik, Bad Säckingen, Alemanha) nos mesmos períodos do Experimento 1. A genotoxicidade do clareamento foi avaliada através da frequência de micronúcleos (MN) do tecido gengival, antes e após o clareamento. Os dados
dos dois Experimentos foram avaliados por análise de variância de dois fatores para medidas repetidas e teste de Tukey para o contraste das médias (α = 0,05). Os dados de variação de
unidades de escala Vita (ΔUEV) e variação de cor (ΔE) mostraram efetividade do clareamento dental em ambos os grupos após três semanas de tratamento. A prevalência de sensibilidade dental foi semelhante entre os grupos. A frequência de MN no grupo experimental foi significativamente maior que no grupo controle, independentemente do tratamento clareador. Pode-se concluir que a efetividade do clareamento e a sensibilidade dental decorrentes do
procedimento não parecem ser afetadas pelo hábito de fumar e o clareamento dental com peróxido de carbamida 10% pode ser considerado um procedimento seguro.
Palavras-chave: Clareamento dental; Tabaco; Testes para Micronúcleos; Sensibilidade da
dentina.
|
462 |
EFEITOS DOS AGENTES CLAREADORES NA ADESIVIDADE E NA SUPERFÍCIE DE BRACKETS METÁLICOS / Effects of bleaching agents on adhesiveness and surface of metallic bracketsBayá, Paola Andrea Zurita 20 February 2014 (has links)
Made available in DSpace on 2017-07-24T19:22:31Z (GMT). No. of bitstreams: 1
Paola Andrea Zurita Baya.pdf: 5901353 bytes, checksum: 64a11dda533f6676e318b6f0b49bd278 (MD5)
Previous issue date: 2014-02-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This study evaluated the effects of bleaching agents on adhesiveness and surface of metallic brackets. To evaluate the bond strength (BS) and adhesive remnant index
(ARI) sixty specimens were confectioned, where sixty brackets were bonded to 60 Premolars with the adhesive TransbondTM XT. They were divided randomly into 3
groups (n=20), a control group (CG) wich not received bleaching agent, two experimental groups TWS and TWO where the bleaching agent hydrogen peroxide 10% (Opalescence® TrèswhiteTM Supreme) and hydrogen peroxide 8% (Opalescence® TrèswhiteTM Ortho) were applied respectively. The specimens were submitted to shearing in a universal testing machine (Kratos) with a crosshead speed of 0,5 mm/min. The ARI was evaluated with a magnifying stereomicroscope (20x). For the evaluation of surface roughness 15 new brackets were used, divided into 3 groups (n=5). These groups correspond to a control group (CG) without bleaching agent, and two experimental groups (TWS e TWO). The brackets underwent to the surface roughness test by digital rugosimeter (Surftest SJ 400). The ANOVA test showed no significant difference for the RA (p = 0.3511), Rug (p= 0.10) nor to changes in roughness (p= 0.1024). The Kruskal-Wallis test showed no significant difference for the ARI (p= 0.3732). It was concluded that the use of
bleaching agents tested in this study is viable in orthodontic patients. / Este estudo avaliou os efeitos dos agentes clareadores na adesividade e na superfície de brackets metálicos. Para a avaliação da resistência adesiva (RA) e do índice de adesivo remanescente (IAR) foram confeccionados 60 corpos de prova, onde 60 brackets foram colados em 60 pré-molares humanos com o adesivo TransbondTM XT. Foram divididos aleatoriamente em 3 grupos (n=20), um grupo controle (GC) que não recebeu agente clareador, dois grupos experimentais TWS e TWO nos quais foram aplicados o agente clareador peróxido de hidrogênio 10%
(Opalescence® TrèswhiteTM Supreme) e peróxido de hidrogênio 8% (Opalescence® TrèswhiteTM Ortho) respectivamente. As amostras foram submetidas a cisalhamento em uma máquina universal de ensaios mecânicos (Kratos) com velocidade de carga de 0,5 mm/min. O IAR foi avaliado com uma lupa estereomicroscópica (20x). Para à avaliação da rugosidade superficial foram utilizados 15 brackets novos, divididos em 3 grupos (n=5). Esses grupos correspondem a um grupo controle (GC) sem agente clareador e dois grupos experimentais (TWS e TWO). Os brackets foram submetidos ao teste de rugosidade superficial pelo rugosímetro digital (Surftest SJ 400, Mitutoyo)
O teste ANOVA demonstrou não existir diferença significativa para a RA (p= 0,3511), Rug. (p= 0,10) e nem para alterações da rugosidade (p= 0,1024). O teste Kruskal-Wallis demonstrou não haver diferença significativa para o IAR (p= 0,3732). Concluise que o uso dos agentes clareadores testados no presente estudo é viável em pacientes ortodônticos.
|
463 |
A ASSOCIAÇÃO ANALGÉSICA PARACETAMOL / CODEÍNA NÃO REDUZ A SENSIBILIDADE INDUZIDA PELO CLAREAMENTO DENTAL: ENSAIO CLÍNICO RANDOMIZADO, PARALELO, TRIPLO-CEGO / ANALGESIC ASSOCIATION ACETAMINOPHEN / CODEINE DOES NOT REDUCE BLEACHING-INDUCED TOOTH SENSITIVITY: A RANDOMIZED, PARALLEL, TRIPLE-BLIND CLINICAL TRIALCoppla, Fabiana Fernandes Madalozzo 28 June 2017 (has links)
Submitted by Eunice Novais (enovais@uepg.br) on 2017-08-17T19:02:15Z
No. of bitstreams: 2
license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5)
FABIANA FERNANDES MADALOZZO COPPLA.pdf: 8129839 bytes, checksum: 555584401fddabd5299b0abdea4be4de (MD5) / Made available in DSpace on 2017-08-17T19:02:15Z (GMT). No. of bitstreams: 2
license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5)
FABIANA FERNANDES MADALOZZO COPPLA.pdf: 8129839 bytes, checksum: 555584401fddabd5299b0abdea4be4de (MD5)
Previous issue date: 2017-06-28 / Introdução: A Sensibilidade dental (SD) induzida pelo clareamento é
altamente prevalente. A combinação de opioides e analgésicos não opioides
pode proporcionar um melhor efeito analgésico. Objetivos: Avaliar o efeito da
associação de paracetamol / codeína administrado pré e pós-operatoriamente
sobre o risco e a intensidade da SD induzida pelo clareamento dental.
Métodos: Realizou-se um ensaio clínico randomizado paralelo, triplo cego,
com 105 pacientes saudáveis os quais receberam um placebo ou uma
associação de paracetamol / codeína. A primeira dose de (paracetamol 500 mg
/ codeína 30 mg) ou placebo foi administrada 1 h antes do clareamento em
consultório (peróxido de hidrogénio 35%) e doses extras foram administradas a
cada 6 h durante 48 h. A SD foi avaliada utilizando duas escalas: 0-10 escala
visual analógica VAS e uma escala de classificação numérica NRS 0-4 em
diferentes períodos: durante o clareamento, 1 h até 24 h, 24 h até 48 h pós
clareamento. A cor foi mensurada antes e um mês após o clareamento dental
com uma escala de cores visuais Vita Classical, Vita Bleachedguide 3D-Master
e espectrofotômetro Vita Easyshade (Vita Zahnfabrik). O risco absoluto de SD
foi avaliado pelo teste exato de Fisher. Os dados da intensidade SD com
escala NRS dos dois grupos foram comparados com os testes de Mann-
Whitney e Friedman, enquanto que os dados da escala VAS foram avaliados
por meio de ANOVA dois fatores de medidas repetidas. As alterações de cor
entre os grupos foram comparadas utilizando teste t de Student (α = 0,05).
Resultados: Não foram observadas diferenças significativas entre os grupos
quanto ao risco e intensidade de SD. O risco absoluto total de SD foi de
aproximadamente 96%. Uma alteração de cor de quase 5 unidades da escala
de cor visual Vita Classical foi detectada em ambos os grupos, que foram
estatisticamente semelhantes (p> 0,05). Conclusão: O uso da associação
paracetamol / codeína pré e pós clareamento de consultório não reduz o risco
e a intensidade da SD induzida pelo clareamento. Implicações clínicas: O uso
de um fármaco analgésico opioide não foi capaz de prevenir SD decorrente de
clareamento dental em consultório. / Background: Bleaching-induced TS is highly prevalent. The combination of
Opioids and non opioids analgesics may provide a better analgesic effect.
Objective: To evaluate the effect of the combination of paracetamol / codeine
administered before and postoperatively on the risk and intensity of TS induced
by dental whitening. Methods: A triple-blind, parallel, randomized clinical trial
was conducted with 105 health patients who received either a placebo or an
association of codeine/acetaminophen. The first dose of Tylex® 30 mg
(acetaminophen 500 mg/codeine 30 mg) or placebo was administered 1 h
before the in-office bleaching (35% hydrogen peroxide), and extra doses were
administered every 6 h for 48 h. The TS was recorded using two scales: 0-10
visual analog scale and a 0-4 numeric rating scale in different periods: during
bleaching, 1 h up to 24 h, 24 h up to 48 h postbleaching. The color was
measured before and one month after dental bleaching with a visual shade
guide Vita Classical, Vita Bleachedguide 3D-Master and spectrophotometer
Vita Easyshade (Vita Zahnfabrik). The absolute risk of TS was evaluated by
Fisher’s exact test. Data of TS intensity with NRS scale of the two groups were
compared with Mann-Whitney and Friedman tests, while data from the VAS
scale were evaluated by two-way repeated measures ANOVA. The color
changes between groups were compared using a Student t-test (α = 0.05).
Results: No significant differences between the groups were observed in the
risk and intensity of TS. The overall absolute risk of TS was approximate 96%.
A color change of nearly 5 shade guide units of the Vita Classical was detected
in both groups, which were statistically similar (p > 0.05). Conclusion: The use
of acetaminophen/codeine association pre and post in-office bleaching does not
reduce the risk and intensity of bleaching-induced TS. Practical Implications:
The use of an opioid analgesic drug was not capable to prevent TS arising from
in-office dental bleaching.
|
464 |
Avaliação clínica dos tempos de aplicação do peróxido de hidrogênio no clareamento em consultórioKose Junior, Carlos 14 August 2014 (has links)
Submitted by Angela Maria de Oliveira (amolivei@uepg.br) on 2017-11-24T12:45:10Z
No. of bitstreams: 1
Carlos Kose Junior.pdf: 8628100 bytes, checksum: 2102f2134392930e820dcd13d8072e3e (MD5) / Made available in DSpace on 2017-11-24T12:45:10Z (GMT). No. of bitstreams: 1
Carlos Kose Junior.pdf: 8628100 bytes, checksum: 2102f2134392930e820dcd13d8072e3e (MD5)
Previous issue date: 2014-08-14 / O objetivo deste estudo clínico foi comparar a eficácia clareadora e a sensibilidade
dental (SD) do clareamento com peróxido de hidrogênio (PH) 35% na técnica em
consultório em diferentes tempos de uso. 53 pacientes com o canino superior direito
mais escuro que A3 foram selecionados para participar neste estudo cego e
randomizado. Os participantes foram distribuídos em três grupos: clareamento com 1
aplicação de 15 minutos de PH 35%; clareamento com 2 aplicações de 15 minutos
de PH 35% e clareamento com 3 aplicações de 15 minutos de PH 35%. As
superfícies vestibulares dos dentes ântero-superiores foram clareadas, em duas
sessões, com uma semana de intervalo. A mudança de cor foi avaliada pelo
espectrofotômetro VITA Easyshade (Vita Zahnfabrik). Os pacientes registraram sua
percepção de SD em uma escala 0-4. A mudança de cor foi analisada pelos testes
de ANOVA e Tukey (α=0,05). O risco absoluto de SD e a intensidade de SD foram
avaliados pelos testes de Fisher e ANOVA/Tukey, respectivamente (α= 0,05). A
redução do número de aplicações do agente clareador (1x15 ou 2x15)
significantemente diminuiu a eficácia do clareamento (p < 0,05). 83% e 94% dos
pacientes dos grupos 2x15 e 3x15, respectivamente, demonstraram, mas apenas no
grupo 3x15, a SD foi significantemente maior que o grupo 1x15 (p < 0,05). A
intensidade de sensibilidade foi menor para o grupo 1x15 em comparação com os
demais grupos (p < 0,05). A redução do número de aplicações para o clareamento
em consultório diminuiu significativamente a SD, entretanto também diminuiu a
eficácia do clareamento. Resultados intermediários em termos de eficácia de
clareamento e de SD foram encontrados quando a técnica de 2 x 15-min de
aplicação foi realizada em cada sessão clínica. / The aim of this clinical study was to compare the bleaching efficacy and tooth
sensitivity (TS) of in-office bleaching applied under different times protocol. Fifty-three
patients with right superior canine darker than A3 were selected to participate in this
single-blind randomized trial. The participants were distributed in three groups: the
bleaching agent was applied once (1x15) for 15 minutes or refreshed every 15
minutes for two (2x15) or three (3x15) times at each bleaching appointment. The
buccal surfaces of the anterior teeth were bleached, in two sessions, using a 35%
(Whiteness HP Maxx, FGM) with one-week interval. The color change was evaluated
by using the VITA Easyshade Spectrophotometer (Vita Zahnfabrik). Participants
recorded TS with a five-point verbal scale. Color change was analyzed by two-way
ANOVA and Tukey’s tests (α=0.05). The absolute risk of TS and TS intensity
evaluated by Fisher’s exact test and two-way ANOVA and Tukey’s tests, respectively
(α= 0.05). The reduction of number of bleaching application (1x15 or 2x15)
decreased the bleaching efficacy (p < 0.05). 83%, and 94% of patients from the 2x15
and 3x15 groups, respectively, experienced tooth sensitivity (p < 0.05), however, only
3x15 group was statistically significant higher than 1x15 (p < 0.05). The intensity of
sensitivity was lower for the 1x15 in comparison to other groups (p < 0.05). The
reducing the number of times the in-office bleaching gel to be applied significant
decrease the TS, but also the bleaching efficacy. Intermediary results in terms of
bleaching efficacy and TS was found when 2 x 15-min of application was performed
in each clinical appointment.
|
465 |
Clareamento dental interno: efeito de diferentes sistemas na microdureza e micromorfologia superficial da dentina bovina / Effect of different bleaching systems on the microhardness and ultrastructure of bovine dentinLaise Daniela Carrasco Guerisoli 07 January 2008 (has links)
Este estudo teve como objetivos: 01.Avaliar ex vivo o efeito de diferentes sistemas clareadores na microdureza dentinária em dentes bovinos submetidos ao clareamento dental interno. 02.Avaliar ex vivo o efeito de diferentes sistemas clareadores na morfologia superficial da dentina bovina. Fragmentos de 4 x 4mm, contendo esmalte e dentina, foram obtidos de coroas de incisivos bovinos extraídos. Os espécimes foram submetidos ao clareamento dental interno com peróxido de hidrogênio a 35% e peróxido de carbamida a 37% utilizando sistemas convencionais (Opalescence Endo® and Whiteness Super Endo®) e fotoativados (Opalescence Xtra® and Whiteness HP Maxx®). Os controles foram tratados com perborato de sódio misturado com peróxido de hidrogênio a 10% ou nenhum tratamento foi realizado. A microdureza dentinária foi mensurada antes e após os tratamentos clareadores, e os valores de dureza Knoop (KHN) foram submetidos à análise estatística (two-way ANOVA, Tukey\'s port-test). Os espécimes foram observados e fotografados sob microscópio eletrônico de varredura e avaliados com relação às alterações morfológicas da superfície da dentina. Houve uma redução significante na microdureza dentinária para todos os grupos testados quando comparados aos grupos controles. Opalescence Xtra® (-11.36 ± 8.14 KHN), Opalescence Endo® (-13.71 ± 8.02 KHN), Whiteness HP Maxx® (-15.18 ± 9.58 KHN) e Whiteness Super Endo® (-16.97 ± 6.55 KHN) foram semelhantes estatisticamente. O grupo do perborato de sódio misturado com peróxido de hidrogênio 10% (2.10 ± 8.58 KHN) e o grupo sem tratamento clareador (-2.71 ± 2.40 KHN) também foram estatisticamente semelhantes entre si. Ocorreu uma grande variação no padrão de alterações da morfologia superficial da dentina com os sistemas clareadores utilizados. Todos os produtos testados apresentaram redução significativa da microdureza dentinária, exceto o grupo de perborato de sódio misturado com peróxido de hidrogênio a 10%. Ambos, pH e oxidação do peróxido de hidrogênio apresentam o papel de alterar a estrutura da dentina durante o clareamento interno. A utilização de produtos alcalinos com um tempo reduzido de aplicação (técnicas fotoativadas) pode diminuir as alterações morfológicas na dentina. / The aim of this study was: 01. To evaluate in vitro the effect of different in-office bleaching systems on the surface morphology of bovine dentin. 02. To evaluate ex vivo the effect of different bleaching systems on the microhardness of bovine dentine. Tooth fragments measuring 4 x 4mm, containing enamel and dentin, were obtained from the crowns of extracted bovine incisors. Samples were submitted to simulated intracoronal bleaching techniques with 35% hydrogen peroxide and 37% carbamide peroxide using conventional (Opalescence Endo® and Whiteness Super Endo®) and light activated systems (Opalescence Xtra® and Whiteness HP Maxx®). Controls were treated either with sodium perborate mixed with 10% hydrogen peroxide or no bleaching agent. Dentine microhardness values were measured before and after bleaching procedures, recorded as KHN (Knoop Hardness Number), and the differences between them analyzed (two-way ANOVA, Tukey\'s port-test). The samples were observed under SEM and the recorded images were evaluated for topographic alterations. Significant reductions of dentine microhardness were observed for all treatments when compared to the control groups. Opalescence Xtra® (-11.36 ± 8.14 KHN), Opalescence Endo® (-13.71 ± 8.02 KHN), Whiteness HP Maxx® (-15.18 ± 9.58 KHN) and Whiteness Super Endo® (- 16.97 ± 6.55 KHN) presented similar differences. The walking bleach technique (2.10 ± 8.58 KHN) and the untreated groups (-2.71 ± 2.40 KHN) were statistically alike.The ultrastructural alterations of dentin observed in this study varied greatly between groups, according to the products used. Apparently, higher pH products associated to in-office techniques yielded to better maintenance of dentin ultrastructure. The in-office products tested in the present study caused a significant reduction in dentine microhardness. The walking bleach technique did not affect dentine microhardness. Both low pH and hydrogen peroxide oxidation play a role in altering the ultrastructure of dentin during internal dental bleaching. The use of alkaline products with reduced time of application (in-office techniques) may decrease such morphological alterations.
|
466 |
Exploring the climate change refugia potential of equatorial Pacific coral reefsDrenkard, Elizabeth Joan January 2015 (has links)
Thesis: Ph. D., Joint Program in Oceanography/Applied Ocean Science and Engineering (Massachusetts Institute of Technology, Department of Earth, Atmospheric, and Planetary Sciences; and the Woods Hole Oceanographic Institution), 2015. / Cataloged from PDF version of thesis. / Includes bibliographical references. / Global climate models project a 21st century strengthening of the Pacific Equatorial Undercurrent (EUC). The consequent increase in topographic upwelling of cool waters onto equatorial coral reef islands would mitigate warming locally and modulate the intensity of coral bleaching. However, EUC water is potentially more acidic and richer in dissolved inorganic nutrients (DIN), both widely considered detrimental to coral reef health. My analysis of the Simple Ocean Data Assimilation product indicates that the EUC has indeed strengthened over the past 130 years. This result provides an historical baseline and dynamical reference for future intensification. Additionally, I reared corals in laboratory experiments, co-manipulating food, light and CO2 (acidity) to test the role of nutrition in coral response to elevate CO2 conditions. Heterotrophy yields larger corals but CO2 sensitivity is independent of feeding. Conversely, factors that enhance zooxanthellate photosynthesis (light and DIN) reduce CO2 sensitivity. Corals under higher light also store more lipid but these reserves are not utilized to maintain calcification under elevated CO2 My results suggest that while mitigation of CO2 effects on calcification is not linked to energetic reserve, EUC fueled increases in DIN and productivity could reduce effects of elevated CO2 on coral calcification. / by Elizabeth Joan Drenkard. / Ph. D.
|
467 |
Avaliação da adesão dental do cimento de ionômero de vidro e resina composta em função do tratamento dentinário com agentes clareadores / Evaluate of the dental bond strength of glass-ionomer cements and composite resin in dentin treated with bleaching agentsNéspoli, Fabiana Gomes 01 October 2009 (has links)
O objetivo desse trabalho foi avaliar in vitro a diferença da força de cisalhamento da dentina quando submetida a ação de algumas substâncias utilizadas como clareadores dentais e posteriormente restaurados com cimento de ionômero de vidro e resina composta. Utilizou-se 152 terceiros molares superiores hígidos que tiveram suas superfícies palatinas desgastadas e preparadas para receber os materiais restauradores após o tratamento com os agentes clareadores.Os dentes foram divididos aleatoriamente em 12 grupos de acordo com as condições em teste a saber: G1: Soro+Resina, G2: Soro+Ionônero de vidro, G3: Perborato de Sódio+Soro+Resina, G4: Perborato de Sódio+Soro+Ionônero de vidro, G5: Perborato de Sódio+Peróxido de hidrogênio 6%+Resina, G6: Perborato de Sódio+Peróxido de hidrogênio 6%+ Ionônero de vidro, G7: Perborato de Sódio+ Peróxido de hidrogênio 35%+Resina, G8: Perborato de Sódio+Peróxido de hidrogênio 35%+ Ionônero de vidro, G9: Peróxido de hidrogênio 6%+Resina, G10: Peróxido de hidrogênio 6%+ Ionônero de vidro, G11: Peróxido de hidrogênio 35%+Resina, G12: Peróxido de hidrogênio 35%+ Ionônero de vidro.Ao término das restaurações os corpos de prova foram levados à máquina de ensaio universal (EMIC) e os resultados obtidos foram analisados através do teste de ANOVA a um critério e Tukey para comprovação de possíveis diferenças estatísticas .Por essas análises podemos concluir que os materiais restauradores tiveram um comportamento equivalente em todos os grupos e as diferenças significantes ocorreram mais por conta do agente clareador, sendo os grupos G1 e G2 aqueles que tiveram melhores resultados ao teste de adesividade, onde podese observar resultados significantes do grupo G1,em relação aos G5, G9, G10 e G11.O peróxido de hidrogênio a 6% ou 35% gerou os piores resultados de adesividade, melhorados com a associação ao perborato de sódio, revelando significância estatística do grupo G7 em relação aos grupos G9, G10 e G11. / The aim of this study was to evaluate \"in vitro the difference of shear bond strength of dentin when subjected to action of some substances used as dental bleaching and then restored with glass-ionomer cements and composite resin. We used 152 healthy third molars that had their palatal surfaces worn and ready to receive the restorative materials after treatment with bleaching agents. The teeth were randomly divided into 12 groups according to the conditions in testing are: G1: Serum + resin, G2: Serum + glass ionomer , G3: sodium perborate + Serum + Resin, G4: sodium perborate + Serum + glass ionomer , G5: sodium perborate + Hydrogen Peroxide 6% + Resin, G6: perborate of Sodium Hydrogen peroxide 6 +% + glass ionomer , G7: sodium perborate + 35% hydrogen peroxide + Resin, G8: sodium perborate + 35% hydrogen peroxide + glass ionomer, G9: Hydrogen peroxide 6% + Resin , G10: Hydrogen peroxide 6% + glass ionomer , G11: Hydrogen peroxide 35% + Resin, G12: Hydrogen peroxide 35% + glass ionomer .Finely finish the restorations of the bodies of evidence were brought to universal testing machine (EMIC) and results obtained and the results were analyzed using the Anova test and a Tukey test for evidence of possible statistical differences. For this analysis we can conclude that the restorative materials had an equivalent behavior in all groups, significant differences occurred due to the bleaching agent, and the G1 and G2 who fared better adhesion to the test, we can observe results significant in the G1, for the G5, G9, G10 and G11.The hydrogen peroxide 6% or 35% yielded the worst results of adhesiveness, enhanced with the combination of sodium perborate, showing statistical significance in the G7 the groups G9, G10 and G11.
|
468 |
Comprometimento do esmalte bovino após escovação em função do condicionamento ácido, clareamento ativado com luz híbrida, concentração e pH dos géis clareadores / Commitment of bovine enamel after brushing in the function of acid etching,whitening activated with hybrid light, and pH concentration of the bleaching gelsSoares, Ana Flávia 04 March 2013 (has links)
Este estudo in vitro avaliou a influência do clareamento ativado com luz híbrida, em função da variação do pH e concentração de géis clareadores, e do condicionamento ácido prévio do esmalte bovino na alteração da rugosidade e desgaste após escovação simulada. Fragmentos de esmalte (1,5cm x 0,5cm x 0,4cm) foram divididos em duas partes, ficando uma metade como controle e a outra como área teste. Esta última foi subdividida em duas metades, sendo que uma recebeu o condicionamento ácido somado ao gel clareador e a outra somente o gel clareador. Os espécimes foram divididos aleatoriamente em seis grupos (n=10): C = controle; TBO35LH = Total Blanc Office 35% 1 sessão (5x8) + ativação com luz híbrida LED/Laser; LPS35LH= Lase Peroxide Sense 35% - 1 sessão (5x8) + ativação com luz híbrida LED/Laser; LPS25LH = Lase Peroxide Sense 25% - 1 sessão (5x8) + ativação com luz híbrida LED/Laser; LPL15LH = Lase Peroxide Lite 15% - 1 sessão (5x8) + ativação com luz híbrida LED/Laser; LPL10LHV = Lase Peroxide Lite 10% - 1 sessão (5x8) + ativação com luz híbrida LED/Laser violeta. A rugosidade aritmética (Ra) inicial, após clareamento e após escovação, foi determinada pela média (μm) de três leituras (em cada área sem e com ácido totalizando seis leituras por espécimes) com o rugosímetro Hommel Tester T 1000. Os valores médios do pH foram determinados pelo peagômetro digital Sentron Model 1001 nos tempos inicial e final. Os espécimes foram armazenados em saliva artificial por sete dias, submetidos a 100.000 ciclos de escovação simulada. Após 24 horas o desgaste superficial foi determinado (μm) empregando o mesmo rugosímetro. Em relação ao desgaste e a alteração de rugosidade superficial, os resultados foram submetidos à Anova a dois critérios e a dois critérios de medidas repetidas e posteriormente ao teste de Tukey. Os dados obtidos das leituras de pH foram submetidos à ANOVA a um critério e a dois critérios de medidas repetidas e ao teste de Kruskal Wallis e Tukey para comparações individuais entre os grupos. Para todos os testes o nível de significância foi de 5%. A rugosidade e o desgaste apontaram diferenças estatísticas entre os grupos, principalmente quando comparado à área com e sem ácido. Os géis clareadores apresentaram tendência de diminuição dos valores de pH do tempo inicial para o tempo final, contudo, uma correlação com a rugosidade e com o desgaste não pôde ser estabelecida de forma clara. / This in vitro study evaluated the influence of whitening activated with hybrid light on the function variations of the pH level and concentration of bleaching gels and prior acid etching of bovine enamel and the change in roughness and wear after simulated tooth brushing. Fragments of enamel (1.5 cm x 0.5 cm x 0.4 cm) were divided into two parts, one half as the control and the other as the test area. The latter was divided into two halves, one of which received the etching added to the whitening gel and the other with only the whitening gel. The specimens were randomly divided into six groups (n = 10): C = control; TBO35LH = 35% Total Blanc Office 1x session (5x8\') + activation with hybrid light LED/Laser; LPS35LH = 35% Lase Peroxide Sense - 1x session (5x8\') + activation with hybrid light LED/Laser; LPS25LH = 25% Sense Lase Peroxide - 1x session (5x8\') + activation with hybrid light LED/Laser; LPL15LH = 15% Lase Peroxide Lite - 1x session (5x8 \') + activation with hybrid light LED/Laser; LPL10LHV = 10% Lase Peroxide Lite - 1x session (5x8\') + activation with violet hybrid light LED/Laser. The arithmetic roughness (Ra) started after bleaching and after brushing was determined by averaging (μm) the three readings (in each area - with and without acid for a total of six readings per specimen) with a Rugosimeter Hommel Tester T 1000. The mean pH values were determined by the Sentron Model 1001 digital pH meter at the start and end times. The specimens were stored in artificial saliva for seven days, and subjected to 100,000 cycles of simulated brushing. After 24 hours, the surface wear was determined (μm) employing the same roughness meter. In relation to the change in wear and surface roughness, the results were evaluated by two way ANOVA testing for repeated measures and later, a Tukey\'s test. The data obtained from the pH readings were submitted to two way ANOVA testing for repeated measures and the Kruskal Wallis and Tukey tests for the comparisons between the individual groups. The significance level was set at 5% for all the tests. The roughness and wear showed statistical differences between the groups, especially when compared to the area with and without acid. The bleaching gels tended to decrease in pH from the starting time to the final time, however, a correlation with the roughness and wear could not be clearly established.
|
469 |
Influência de agentes clareadores na rugosidade de compósitos dentários / Influence of bleaching gels on roughness of dental compositesEduardo Varanda 18 December 2009 (has links)
O clareamento dental é o meio disponível mais simples, comum e conservador para o cirurgião-dentista proporcionar aos pacientes o padrão de cor de seus dentes mais desejado. Em alguns casos, os dentes que vão ser clareados podem apresentar restaurações realizadas com compósitos dentais, que são mais suscetíveis a alterações químicas, quando comparados a outros materiais restauradores. Alguns estudos mostraram que diferentes concentrações de agentes clareadores levaram a um aumento significativo da rugosidade superficial e das porosidades em compósitos dentais. Este estudo avaliou o efeito de dois agentes clareadores (Whiteness HP Blue 20%, Whiteness HP Max) sobre a rugosidade superficial de dois compósitos dentais, um micro-híbrido (Esthet X, Denstply) e outro nanoparticulado (Z 350, 3M ESPE). Um total de oito corpos de prova (9 x 2 mm) foram confeccionados com auxílio de uma matriz de teflon, sendo divididos em 4 grupos (Esthet X + Whiteness HP Blue 20%; Esthet X + Whiteness HP Max; Z 350 + Whiteness HP Blue 20%; Z 350 + Whiteness HP Max), sendo n=2. Os corpos de prova foram armazenados em saliva artificial neutra e, após 24 horas, foram polidos com discos de óxido de Alumínio (Sof-lex, 3M ESPE). Após sete dias de imersão salivar, cada corpo de prova foi levado a um microscópio de força atômica para obtenção do valor inicial de rugosidade superficial (Ra em nm). Em seguida, sem remover o corpo de prova do microscópio, o agente clareador foi aplicado sobre a superfície do corpo de prova, segundo as instruções do fabricante, de modo que permitisse uma posterior observação da mesma área do corpo de prova observada inicialmente, para obtenção do valor final de rugosidade superficial. Imagens em duas e três dimensões foram obtidas de cada corpo de prova para observação de alterações da topografia. Os resultados foram tratados estatisticamente por ANOVA e pelo teste de contraste Student-Newman-Keuls (p < 0,05). Não houve alteração significativa na rugosidade superficial (Ra) dos corpos da prova de compósitos micro-híbrido e nanoparticulado, submetidos aos agentes clareadores Whiteness HP Blue 20% e Whiteness HP Maxx. No entanto, independente do agente clareador utilizado, foram observadas maiores alterações topográficas nas imagens de microscopia de força atômica da superfície do compósito micro-híbrido do que nas imagens do nanoparticulado. / Dental bleaching is the simplest, the most common and conservative available way for dentists to offer their patients the standard color of teeth more desired. In some cases, the teeth that will be bleached may include restorations made of resin composites, which are more prone to chemical alteration compared with other restoration materials. Some studies have showed that different concentrations of bleaching gels might lead to a significant increase in surface roughness and amount of porosities in composite resins. This study evaluated the effect of two bleaching gels (Whiteness HP Blue 20%, Whiteness HP Max) on surface roughness of two resin composites, micro-hybrid (Esthet X, Denstply) and nanoparticled (Z350, 3M ESPE). A total of eight specimens (9 x 2 mm) were produced with a Teflon mold help, and were divided into four groups (Esthet X + Whiteness HP Blue 20%; Esthet X + Whiteness HP Max; Z 350 + Whiteness HP Blue 20%; Z 350 + Whiteness HP Max), with n=2. They were stored in neutral artificial saliva and, after 24 hours, were polished with aluminium oxide discs (Sof-lex, 3M ESPE). After seven days of salivary immersion, each specimen was taken to an atomic force microscope for recording initial value of surface roughness (Ra in nm). After that procedure, without removing the specimen from microscope, the bleaching gel was applied on the surface of the specimen, following manufacturers instructions, in order to allow posterior observation of the same area of the specimen initially observed, for recording the final value of surface roughness. Two-dimensional and 3D images were taken from each specimen group for observation of surface alterations. The results were statistically analyzed by ANOVA and the SNK test (p< 0.05). There were no statistically significant differences in the surface roughness (Ra) for specimens of micro-hybrid and nanoparticled composites, submitted to the bleaching agents Whiteness HP Blue 20% and Whiteness HP Maxx. However, there were noticed larger surface alterations in atomic force microscope images on the surface of micro-hybrid composites than on the nanoparticled, independently of the bleaching agent used.
|
470 |
Efeito de agentes remineralizantes sobre a microdureza, cor e desgaste do esmalte dental clareado / Effect of remineralizing agents on the microhardness, color and wear enamel bleachedCrastechini, Érica [UNESP] 06 February 2017 (has links)
Submitted by ÉRICA CRASTECHINI null (e_cras@ig.com.br) on 2017-03-17T12:34:04Z
No. of bitstreams: 1
Tese Doutorado - Érica Crastechini.pdf: 1828754 bytes, checksum: fd9d04fce38028ef480de9b998017af4 (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2017-03-21T19:10:47Z (GMT) No. of bitstreams: 1
crastechini_e_dr_sjc.pdf: 1828754 bytes, checksum: fd9d04fce38028ef480de9b998017af4 (MD5) / Made available in DSpace on 2017-03-21T19:10:47Z (GMT). No. of bitstreams: 1
crastechini_e_dr_sjc.pdf: 1828754 bytes, checksum: fd9d04fce38028ef480de9b998017af4 (MD5)
Previous issue date: 2017-02-06 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar o efeito da aplicação de agentes remineralizantes contendo silicato de cálcio / fosfato e flúor ou fluoreto de sódio somente, sobre a redução da microdureza do esmalte causada pelo clareamento dental, cor dos dentes e perda de estrutura resultante da abrasão. Duzentos e quarenta amostras circulares de esmalte bovino foram preparadas, embutidas e polidas. Em seguida foram realizados testes iniciais de cor, microdureza e perfilometria. As amostras foram distribuídas aleatoriamente em 6 grupos (n=40): Grupo C –(controle negativo) – nenhum tratamento; Grupo CL (controle positivo)- Aplicação do agente clareador a base de peróxido de hidrogênio a 40% (Opalescence boost, Ultradent); Grupo CL/Rs – Aplicação do agente clareador seguido da aplicação do gel remineralizante a base de silicato de cálcio/fosfato (Regenerate Boosting serum- Unilever); Grupo Rs/CL - Aplicação do gel de silicato de cálcio/fosfato seguido da aplicação do agente clareador; Grupo Rs/CL/Rs - Aplicação do gel de silicato de cálcio/fosfato seguida da aplicação do agente clareador e aplicação novamente do gel de silicato de cálcio/fosfato; Grupo CL/F – Aplicação do agente clareador seguida da aplicação do gel de fluoreto de sódio a 2%. Após a etapa de clareamento (3 aplicações de 20 min) foram novamente realizadas as leituras de cor e microdureza. Em seguida os espécimes foram submetidos a 100.000 ciclos abrasivos em máquina de escovação. Cada grupo foi dividido em dois subgrupos de acordo com o dentifrício utilizado (n=20): Subgrupo Cp –creme dental Close Up proteção bioativa (Unilever); Subgrupo Rp- creme dental Regenerate (Unilever). Os perfis finais das superfícies do esmalte foram avaliados e o desgaste calculado. Os dados foram analisados utilizando o teste de análise de variância ANOVA e Tukey. Diferenças significativas foram observadas para a variação de cor (∆E) (p = 0,000). Os resultados do teste Tukey foram: C (1,31±0,58)a , Rs/CL/Rs (3,72±1,28)b, CL (3,75±1,04)b , CL/Rs (3,87±0,91)b, Rs/CL (3,88±0,94)b, CL/F (4,03±1,22)b. Diferenças estatisticamente significantes foram observadas para a microdureza (Knoop) após os tratamentos (p= 0,00001). Os resultados do teste Tukey foram: CL (246,28±30.46)a, Rs/CL/Rs (263,55±18,66)b, CL/Rs (264,06±28,54)b, Rs/CL (265,22±23,58)b, CL/F (269,10±25,66)b C (323,28±10,96)c. Para o desgaste dental (µm) o teste ANOVA a dois fatores mostrou diferenças significativas entre os grupos e os dentifrícios. Os resultados do teste de Tukey para os grupos foram: CL/F (2,12±0,70)a, Rs/CL (2,13±0,85)a, Rs/CL/Rs (2,19±0,70)a, CL/Rs (2,23±0,91)a, C (2,85±0,98)b , CL (3,36±0,84)c. Os resultados do teste de Tukey para os dentifrícios foram: Rp (2,04±0,80)a, Cp (2,92±0.88)b. Concluiu-se que todos os tratamentos com géis remineralizantes testados minimizaram a redução da microdureza promovida pelo clareamento, embora não evitaram que ela acontecesse. Além disso, a aplicação desses não interferiu na mudança da cor promovida pelo clareamento dental. O clareamento sozinho aumentou o desgaste abrasivo dos dentes, porém todos os tratamentos da superfície com géis remineralizantes testados reduziram a perda de estrutura por abrasão. O dentifrício Regenerate resultou em menor desgaste abrasivo do esmalte em relação ao Close UP. Não existiram diferenças significativas entre os diferentes tratamentos remineralizantes com relação aos efeitos sobre a microdureza, cor e desgaste. / This study aimed to evaluate the effect of the application of remineralizing agents containing calcium/phosphate silicate and fluoride or only sodium fluoride on the reduction of enamel microhardness caused by tooth bleaching, tooth color and loss of structure resulting from abrasion. Two hundred and forty circular bovine enamel samples were prepared, embedded and polished. After that, initial tests of color, microhardness and profile were performed. Samples were randomized into six groups (n=40): Group C - (negative control) - no treatment; Group CL (positive control) – application of 40% hydrogen peroxide bleaching agent (Opalescence boost, Ultradent); Group CL/Rs - Application of bleaching agent followed by remineralizing gel based on calcium/phosphate silicate (Regenerate Boosting serum- Unilever); Group Rs/CL – Application of calcium/phosphate silicate gel followed by bleaching agent; Group Rs/CL/Rs – Application of calcium/phosphate silicate gel followed by bleaching agent and new application of calcium/phosphate silicate gel; Group CL/F – Application of bleaching agent followed by 2% sodium fluoride gel. After bleaching stage (3 applications/20 min), color and microhardness readings were performed. Then, the specimens were subjected to 100.000 abrasive cycles in a brushing machine. Each group was divided into two subgroups according to the dentifrice used (n=20): Subgroup Cp –Close Up bioactive protection toothpaste (Unilever); Subgroup Rp- Regenerate toothpaste (Unilever). Final profiles of enamel surface were evaluated and the wear was calculated. Data were analyzed using ANOVA and Tukey variance analysis. Significant differences were observed for color variation (∆E) (p=0.000). Tukey test results were: C (1.31±0.58)a, Rs/CL/Rs (3.72±1.28)b, CL (3.75±1.04)b, CL/Rs (3.87±0.91)b, Rs/CL (3.88±0.94)b, CL/F (4.03±1.22)b. Statistically significant differences were observed for microhardness (Knoop) after treatments (p=0.00001). Tukey test results were: CL (246.28±30.46)a, Rs/CL/Rs (263.55±18.66)b, CL/Rs (264.06±28.54)b, Rs/CL (265.22±23.58)b, CL/F (269.10±25.66)b, C (323.28±10.96)c. For dental wear (µm), two-factor ANOVA test showed significant differences among groups and dentifrices. Tukey test results were were: CL/F (2.12±0.70)a, Rs/CL (2.13±0.85)a, Rs/CL/Rs (2.19±0.70)a, CL/Rs (2.23±0.91)a, C (2.85±0.98)b, CL (3.36±0.84)c. Tukey test results for the dentifrices were: Rp (2.04±0.80)a, Cp (2.92±0.88)b. It was concluded that all treatments with the remineralizing gels minimized the reduction of microhardness promoted by bleaching, although they did not prevent it from happening; In addiction, their application did not interfere in the color change promoted by dental bleaching. Bleaching alone increased the abrasive wear of the teeth. However, all surface treatments, with the remineralizing gels, reduced abrasion structure. Regenerate toothpaste resulted in less abrasive enamel wear regarding Close up toothpaste. There were no significant differences among the different remineralizing treatments with regarding their effects on microhardness, color and wear.
|
Page generated in 0.0521 seconds