• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 19
  • Tagged with
  • 19
  • 19
  • 18
  • 15
  • 13
  • 7
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Efeito do tratamento com gel clareador na relação cálcio-fósforo do esmalte dentário /

Scannavino, Fábio Luiz Ferreira. January 2008 (has links)
Resumo: O clareamento dentário tem sido uma prática popular no consultório odontológico, pois remove pigmentações que tornam o dente escuro, obtendo-se dessa maneira um resultado estético satisfatório. O objetivo do estudo foi avaliar a relação Cálcio-Fósforo (Ca-P) e o efeito da saliva nos dentes submetidos ao clareamento dentário com peróxido de hidrogênio 35%. Foram utilizados 60 espécimes provenientes de 30 incisivos centrais bovinos hígidos, divididos em seis grupos distintos. Os espécimes do grupo controle foram imersos em água destilada. No grupo 1, realizou-se somente clareamento com peróxido de hidrogênio 35% ativado por LED. No grupo 2 foi realizado o clareamento com peróxido de hidrogênio 35% e imersão em saliva artificial por dois dias. No grupo 3 foi realizado o clareamento com peróxido de hidrogênio 35% e aplicação de flúor tópico neutro 2%. No grupo 4 após o clareamento com peróxido de hidrogênio 35% seguido de flúor tópico neutro 2%, os espécimes foram imersos em saliva artificial por dois dias e, no grupo 5 repetiu-se o procedimento do grupo 4 com a imersão em saliva artificial por quinze dias. Todos os espécimes foram preparados para análise por espectrometria de emissão atômica com plasma acoplado indutivamente (ICP-AES). A análise de variância revelou diferença estatística (p<0.05) entre os grupos: o grupo 3 apresentou redução de 7,5% na relação Ca-P comparado ao controle. No entanto, os valores dos grupos 1, 4 e 5 não diferiram significantemente do grupo controle. Os resultados evidenciam que o clareamento produz uma redução na proporção Ca-P que pode ser minimizada pela ação da saliva. / Abstract: Teeth whitening has been a popular procedure in dental offices, because it removes pigmentations that make a tooth become dark, obtaining in this way a satisfactory aesthetic outcome. The aim of this study was to assess the Calcium-Phosphorus (Ca-P) and the effects of saliva on the teeth that had undergone whitening using hydrogen peroxide 35%. 60 specimens from bovine incisors were used, divided into six distinct groups. The specimens from the control group were immersed in distillated water. In group 1, the whitening was made by using hydrogen peroxide 35% activated by LED. In group 2, the whitening using hydrogen peroxide 35% and immersion in artificial saliva for two days was performed. In group 3, the whitening was made by with hydrogen peroxide 35% and application of neutral topic fluoride 2%. In group 4, after the whitening using hydrogen peroxide 35% followed by neutral topic fluoride 2%, the specimens were immersed in artificial saliva for two days and, in group 5, the same procedure as in group 4 was performed, but they were immersed in artificial saliva for 15 days. All specimens were prepared for analysis for Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES). The variance analysis revealed statistical difference (p<0.05) between the groups, and group 3 presented a 7.5% reduction in to Ca-P compared to control. However, the values for groups 1, 4, and 5 did not differ significantly from the control group. The results show that whitening produces a reduction in the ratio Ca-P that can be minimized by the action of the saliva. / Orientador: Lourdes Aparecida Martins dos Santos-Pinto / Coorientador: Antonio Carlos Hernandes / Banca: Angela Cristina Cilense Zuanon / Banca: Lizeti Toledo de Oliveira Ramalho / Banca: Maria Cristina Borsatto / Banca: Marlei Seccani Galassi / Doutor
12

Avaliação dos efeitos causados por diferentes sistemas de clareamento dental sobre a estrutura superficial do esmalte e resina composta restauradora /

Daniel, Carolina Pratti. January 2011 (has links)
Orientador: Carlos Alberto de Souza Costa / Banca: Flávia Magnani Bevilacqua / Banca: Marcelo Ferrarezi de Andrade / Resumo: O objetivo deste estudo foi avaliar as alterações de microdureza, rugosidade e morfologia superficial do esmalte e da resina composta após diferentes técnicas de clareamento dental. Para isto, incisivos bovinos foram selecionados, sendo confeccionadas cavidades padronizadas na face vestibular, as quais foram restauradas com resina composta. Os dentes foram distribuídos em grupos (n=6), de acordo com o tratamento proposto: G1- clareamento com gel de peróxido de carbamida (PC) 10%; G2 - clareamento com gel contendo 38% peróxido de hidrogênio (PH); G3- clareamento com gel contendo 38% de PH associado à irradiação com luz. Para G1, o agente clareador foi aplicado por 8 horas diárias durante 21 dias. Para G2 e G3, foram realizadas 3 sessões, compostas por 3 aplicações do gel clareador por 15 minutos, com intervalos de 7 dias entre as sessões, sendo que em G3 foi aplicada luz LED (470nm) por 6 minutos. Durante o intervalo das aplicações do gel clareador, todos os espécimes foram armazenados em saliva artificial. A microdureza Knoop do esmalte e da resina composta foi avaliada antes do procedimento clareador e nos períodos de 1, 7, 14 e 21 dias pós-clareamento. A rugosidade superficial foi analisada por meio de um rugosímetro e a morfologia superficial por um microscópio de força atômica. Os dados foram analisados pelos testes de Mann-Whitney e Wilcoxon. Observou-se diminuição significante na dureza do esmalte para G2 e G3 após a 2ª e 3ª sessões, respectivamente, em relação à dureza inicial (p<0,05). Para a resina composta, esta alteração foi observada em G1 apenas após 21 dias, e em G2 e G3 após a 3ª sessão (p<0,05). Alterações significantes na rugosidade e morfologia superficial foram observadas apenas para o esmalte do grupo G1 (p<0,05). Concluiu-se que o gel com 10% de PC... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate changes in microhardness, roughness and surface morphology of enamel and composite resin after different techniques of tooth bleaching. Standardized cavities prepared on the buccal surface of bovine incisors were restored with composite resin. The teeth were divided into groups (n=6) according to the following treatments: G1 - bleaching with 10% carbamide peroxide (CP) gel; G2 - bleaching with 38% hydrogen peroxide (HP) gel; G3 - bleaching with 38% PH gel associated to light irradiation. In G1, the whitening agent was applied for 8 hours daily during 21 days. In G2 and G3, three sessions characterized by three applications of bleaching gel for 15 minutes, with intervals of 7 days between sessions were performed. In G3, the bleaching gel was irradiated with LED (470nm) for 6 minutes. During the intervals among applications of the bleaching gel on enamel, all specimens were stored in artificial saliva. The Knoop microhardness of enamel and composite resin was evaluated before the bleaching procedure and at 1, 7, 14 and 21 days after this treatment. The roughness and superficial morphology (atomic force microscope) were evaluated before and at 21 days after the bleaching procedure. Data were analyzed by Mann-Whitney and Wilcoxon statistical tests. It was observed a significant decrease in hardness of enamel to G2 and G3 after the 2nd and 3rd bleaching sessions, respectively, when compared to the initial enamel hardness (p <0.05). For composites, this change was only observed in G1 after 21-day treatment, and in G2 and G3 after the third bleaching session (p <0.05). Significant changes in roughness and surface morphology of enamel was observed only in G1 (p <0.05). According to the experimental conditions, it was possible to conclude that the bleaching gel with... (Complete abstract click electronic access below) / Mestre
13

Avaliação in vitro da efetividade de associações de agentes clareadores na alteração da cor de dentes manchados por pigmentos sangüineos /

Yui, Karen Cristina Kazue. January 2006 (has links)
Orientador: José Roberto Rodrigues / Banca: Marianne Spalding / Banca: Maria Antonio Pereira / Banca: Sérgio Eduardo de Paiva Gonçalves / Banca: Maria Amélia Máximo de Araújo / Resumo: O objetivo deste estudo foi avaliar in vitro a efetividade de três associações de materiais clareadores na técnica mediata de clareamento de dentes tratados endodonticamente. Foram utilizados 48 pré-molares humanos íntegros, pigmentados artificialmente com sangue humano. Após preparo biomecânico, os canais radiculares foram obturados e o tampão cervical foi confeccionado com 3mm de cimento de fosfato de zinco ao nível da junção amelo-cementária. Os dentes foram divididos em quatro grupos (n=12): C (controle, sem material clareador), A1 (perborato de sódio + água destilada), A2 (perborato de sódio + peróxido de carbamida a 10%) e A3 (perborato de sódio + peróxido de carbamida a 35%). Os materiais clareadores foram trocados aos sete e 14 dias. Concluiu-se que o perborato de sódio associado ao peróxido de carbamida (tanto a 10%, como a 35%) foi mais efetivo do que quando associado à água destilada. / Abstract: The aim of this study was to evaluate in vitro the effectiveness of three associations of bleaching agents on artificially stained pulpless teeth. Forty-eight recently extracted intact human premolars were stained by immersing them in human blood, and divided into four groups. All teeth were endodontically treated and 3mm of zinc phosphate cement was placed at the cementoenamel junction. The teeth were divided into one control group and three test groups (n=12): C) control group, without bleaching agent, A1) sodium perborate with water, A2) sodium perborate with 10% carbamide peroxide, A3) sodium perborate with 35% carbamide peroxide. On days 7 and 14, each pulp chamber was refilled with fresh bleaching paste. Color coordinates of CIELAB color system were measured and assessed with the aid of a dental spectrophotometer (EasyShade®, Vita). It was concluded that sodium perborate mixed with carbamide peroxide (10% or 35%) was more effective than mixed with water. / Doutor
14

Avaliação in vitro da eficácia da fotoativação no clareamento dental utilizando a técnica em consultório /

Araújo, Rodrigo Maximo de. January 2008 (has links)
Orientador: Carlos Rocha Gomes Torres / Banca: Henrique Duque de Miranda Chaves Filho / Banca: Ricardo Amore / Banca: Carlos Augusto Pavanelli / Banca: César Rogerio Pucci / Resumo: O objetivo deste estudo foi avaliar se fontes de luz aumentam a eficácia do peróxido de hidrogênio na técnica de clareamento profissional. Para tal, 60 dentes incisivos bovinos foram extraídos e limpos com lâminas de bisturi. As dimensões coronárias e radiculares foram padronizadas a partir do limite amelo-cementário, procedendo-se os devidos cortes perpendiculares na região incisal e apical. A porção lingual foi removida por corte longitudinal, recebendo a superfície vestibular uma profilaxia com jato de bicarbonato de sódio, sendo a porção dentinária exposta, condicionada com H3PO4 a 38% por 15s. Os corpos-de-prova foram levados a um banho de água em ultra-som por 20 min e a seguir imersos em solução de café solúvel a 25%, por duas semanas. A seguir, a porção dentinária foi impermeabilizada com esmalte para unhas incolor e a face vestibular polida com pasta de óxido de alumínio e disco de feltro. Os corpo-de-prova foram divididos aleatoriamente em 5 grupos, sendo a cor inicial mensurada através do espectrofotômetro-EasyShade (VITA-Zahnfabrik, Bad Sackingen, Alemanha ). Todos os corpos-de-prova receberam três aplicações por 15 min do gel clareador Opalescence Xtra-Boost (Ultradent South Jordan, UT, USA). O grupo 1 não recebeu fotoativação, sendo considerado controle, grupo 2 foi ativado com um fotopolimerizador de luz halôgena, grupo 3 ativado com aparelho híbrido de LED azul /LASER, grupo 4 ativado com aparelho de LED verde /LASER e grupo 5 ativação com LED vermelho. Após o clareamento foi novamente mensurada a cor. Os dados de variação de cor ΔE, Δa*, Δb*e ΔL* e os referentes a escala de cor Vita Clássico, foram submetidos a análise de variância e teste de Tukey e Dunn ( p = 5%). Concluimos que: o desempenho do peróxido de hidrogênio a 38 %, teve seu efeito intensificado conforme a fonte de luz utilizada;a diferença... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this in vitro study was to evaluate of the Light Activations of in office bleaching agent technique increase the effectiveness of the procedure, measured by the change of teeth's color. In this study, 60 bovine incisor teeth were extracted, specimen's size was standardized and dentin portion was exposed by carburundum disks. All the surfaces received a sodium bicarbonate prophylaxis and then conditioned by 38% phosphoric acid during 15s. The samples were then brought to a water bath in ultrasound for 20 min and immersed in a 25% soluble coffee solution for two weeks period. Then, the portion dentin was polished with felt's disk and aluminium oxide paste, and finally sealed with colorless ink nail. The specimens were randomly divided into 5 groups, and the original color measured by spectrophotometer - EasyShade (VITA-Zahnfabrik, Bad Sackingen, Germany). All specimens received three applications of bleaching agent Opalescence Xtra-Boost (Ultradent South Jordan, UT, USA) during a period of 15 min each. Group 1 did not receive light activation and was considered as a Control Group, Group 2 was activated with a Halogen light (15 min), Group 3 was activated with hybrid of blue LED / Laser (15 min), Group 4 was activate with green LED / Laser (15min) and Group 5 activated with red Laser (15 min). The color was measured again after bleaching in all specimens. The data of changing color variation ΔE, Δa*, Δb* and ΔL* and those references on Vita Classic, were subjected to ANOVA, Tukey's test and Dunn (p = 5%). The performance of hydrogen peroxide 38% was affected by the source of light used. Significantly differences in reduction of color were observed with all light activators employed and particularly with the blue LED light and Halogen. Quantitative... (Complete abstract click electronic access below) / Doutor
15

Influência do clareamento dental na cor, translucidez e fluorescência do esmalte e dentina /

Caneppele, Taciana Marco Ferraz. January 2011 (has links)
Orientador: Carlos Rocha Gomes Torres / Banca: Alessandra Bühler Borges / Banca: Sergio Eduardo de Paiva Gonçalves / Banca: Glauco Fioranelli Vieira / Banca: Osmir Batista de Oliveira / Resumo: O objetivo deste estudo foi avaliar a cor, translucidez e fluorescência do esmalte e dentina bovinos submetidos a diferentes técnicas de clareamento. Material e Método: Foram utilizados 150 dentes bovinos, dos quais foram obtidos pares de discos de esmalte e dentina com 3mm de diâmetro. Em 75 pares, 1 dos espécimes teve o esmalte removido, sendo denominado Grupo Dentina. Os espécimes de dentina e esmalte obtidos do restante dos pares foram denominados Grupo Esmalte+dentina. E finalmente, 75 espécimes tiveram a dentina removida e foram denominados Grupo Esmalte. A medição da cor, translucidez e fluorescência foi realizada por um espectrofotômetro usando o CIE L * a * b*. Cada grupo foi subdividido em 3 subgrupos: Controle, composto por espécimes que não foram clareados e 2 sugrupos experimentais, clareados com Peróxido de Carbamida 10% (PC10%) ou Peróxido de hidrogênio a 35% (PH 35%). O gel clareador foi aplicado 2h/dia sobre os espécimes para o clareamento com PC10% durante 14 dias e duas aplicações de 30 min com intervalo de uma semana entre as aplicações no clareamento com PH35%. Nos períodos intermediários, os espécimes foram imersos em saliva artificial. As avaliações de cor foram realizadas 7 dias após o término do tratamento. Resultados: Em relação a cor, foram encontradas diferenças significativas entre as técnicas de clareamento nos grupos Esmalte e Esmalte + Dentina, com maior diferença de cor para o PH 35%. O clareamento não alterou a translucidez dos tecidos dentais e a fluorescência diminuiu, apresentando diferenças significantes para o Grupo Dentina, subgrupo PH 35%, Grupo Esmalte, subgrupo PC10% e Grupo Esmalte+dentina, subgrupo PH35%. Conclusão: O clareamento dental alterou a cor e a fluorescência dos tecidos dentais, porém a translucidez não foi afetada / Abstract: The objective of this study was to evaluate the color, translucency and fluorescence of bovine enamel and dentin submitted to different bleaching modalities. Methods: A total of 150 bovine teeth were used, which were obtained pairs of enamel and dentin discs 3mm in diameter. In 75 pairs, one of the specimens had the enamel removed (Group Dentin). Specimens of dentin and enamel obtained from the remaining pair were named Group Enamel+dentin. And finally, 75 specimens were removed from the dentin and enamel were named Group Enamel. The measurement of color, translucency and fluorescence was performed by a spectrophotometer using the CIE L * a * b. Each group was subdivided into three subgroups: Control, composed of specimens that were not bleached and two experimental subgroups, bleached with carbamide peroxide 10% (CP10%) or hydrogen peroxide 35% (HP 35%). The whitening gel was applied on specimens for 2h/day bleaching with CP10% for 14 days and two applications of 30 minutes with one week interval between applications in bleaching with HP35%. In interim periods, the specimens were immersed in artificial saliva. The color ratings were performed 7 days after the treatment. Results: Regarding the color, significant differences were found among bleaching techniques in the groups enamel and dentin + enamel, with a higher color difference for the 35% HP. Bleaching did not change the translucency of the dental tissues and the fluorescence showed significant differences for the 35% HP subgroups in Dentin and Enamel+dentin group, and for 10%CP subgroups in Enamel group. Conclusion: The dental bleaching changed the color and fluorescence of the dental tissues, however translucency was not affected / Doutor
16

Investigação da quebra de pigmentos por luz /

Esteban Florez, Fernando Luis. January 2009 (has links)
Orientador: Osmir Batista de Oliveira Júnior / Banca: Vanderlei Salvador Bagnato / Banca: Carlos EduardoFrancci / Resumo: O clareamento dental é uma técnica que surgiu no inicio do século XIX. Desde então, e em função dos resultados obtidos ao longo do tempo, esta foi sendo alterada de maneira a reduzir os riscos do procedimento e ao mesmo tempo melhorar o resultado estético obtido. Com o aparecimento das fontes de luz para uso odontológico, novas e interessantes possibilidades surgiram e permitiram a utilização de métodos de aceleração que respeitem a fisiologia pulpar, que diminuam o tempo de exposição do paciente aos agentes peróxidos e promovam ainda a obtenção de bons resultados estéticos. Nos dias de hoje, pode-se observar na literatura importantes questionamentos acerca da contribuição efetiva da luz visível no processo e, os efeitos dos agentes peróxidos nas estruturas cristalinas dos dentes, materiais restauradores em geral e tecidos moles. Estas preocupações foram o cerne da motivação para a realização desta pesquisa, sendo assim, este trabalho vem propor uma série de metodologias inovadoras que avaliem através de tecnologias modernas os mecanismos básicos de interação da luz visível com o peróxido de hidrogênio e com os pigmentos orgânicos. Os experimentos aqui demonstrados abordam os fatores críticos relacionados com a eficiência do processo em diferentes substratos por meio de análise de transmitância, de fluorescência e imagens digitais. Com estes estudos pretendemos responder de maneira objetiva algumas das questões que foram observadas serem de fundamental importância no esclarecimento da real eficiência e eficácia da luz no clareamento dental. / Abstract: The dental bleaching is a technique that appeared in the beginning of the XIX century. Since then, and in function of the obtained results a long the time, this has been altered in way to reduce the procedure risks and at the same time improve the aesthetic results. With the rise of light sources to be used in dentistry, new and exciting possibilities appeared and allowed the use of catalytic methods that respect the pulpal physiology, which diminishes the exposure time of the patients to the bleaching agents and provides good aesthetic results. In nowadays, it is possible to observe in the literature important questionings over the real contribution of light in the process and, the effects of the peroxide over the crystalline structure of the teeth, restorative materials and soft tissues. These concerning were the major motivation to the realization of this research, in this way, this work proposes a new series of methods that asses by the use of new technologies the basic mechanisms of visible light interaction with the hydrogen peroxide and with the organic pigments. The experiments here demonstrated study the critical factors related with the process efficiency in different substrates by digital images, transmittance and fluorescence. With these studies we pretend to respond in objective way some questions that were observed to be of fundamental importance in the understanding of the light efficiency and efficacy to the dental bleaching. / Mestre
17

Clareamento com peróxido de hidrogênio a 35% ativado por diversas fontes de energia : análise térmica e microdureza do esmalte /

Kabbach, William. January 2008 (has links)
Orientador: Marcelo Ferrarezi de Andrade / Banca: João Carlos Gomes / Banca: Carlos Alberto de Souza Costa / Resumo: O objetivo do presente estudo foi avaliar in vitro a variação de temperatura e a microdureza Knoop superficial do esmalte durante o processo de clareamento dental com peróxido de hidrogênio a 35% sob irradiação da luz halógena com o comprimento de onda de 400 a 500nm (HL), luz emitida por diodo com comprimento de onda de 460 de 480 (LED) e laser de diodo (DL) de alta intensidade e comprimento de onda de 810nm, em dentes humanos extraídos. Inicialmente investigou-se a variação de temperatura superficial através da termografia de infravermelho e a temperatura do interior da câmara pulpar por meio de termopares em incisivos inferiores humanos, quando submetidos ao clareamento dental com peróxido de hidrogênio a 35% nas cores vermelha (HP) e verde (HPM) irradiados por: HL e LED. Quatro grupos (n=10) foram divididos de acordo com o gel clareador e a fonte de luz. Os resultados foram submetidos à análise de variância e teste de Tukey (p < 0,05). Os valores médios e desvios padrão do aumento de temperatura dentro da câmara pulpar com a HL foram de 4.4 ± 2.1 °C para HP, e 4.5 ± 1.2 °C para HPM; enquanto que nos grupos usando LED, foram 1.4 ± 0.3 °C para HP, e 1.5 ± 0.2 °C para HPM. Para todas as temperaturas superficiais a variação máxima dos grupos irradiados com HL foi 6.5 ± 1.5 °C para HP, e 7.5 ± 1.1 °C usando HPM; enquanto para os grupos usando LED, foram 2.8 ± 0.7 °C usando HP, e 3 ± 0.8 °C para HPM. Não houve diferença estatística entre o aumento da temperatura pulpar e superficial entre os grupos usando os diferentes géis (p < 0,05). As médias de temperatura foram significativamente maiores para os grupos usando HL quando comparados com aqueles irradiados com LED (p < 0,05). Ainda foi investigada a variação de temperatura superficial e assim determinado o tempo de demora para ser atingida a variação crítica de temperatura...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of this in vitro study was to evaluate the variation of temperature and Knoop microhardness on enamel surface during the bleaching process whith 35% hydrogen peroxide under irradiation by halogen light whit the wavelength of 400 to 500nm (HL), LED whit the wavelength of 460 to 480nm and high intensity diode laser LED whit the wavelength of 810nm (LD) on extracted human teeth. Initially were investigated the variation of surface temperature (infrared thermography) and the temperature of the interior of the pulp chamber (thermocouples) in human mandibular incisors when subjected to dental bleaching with 35% hydrogen peroxide in the colors red (HP) and green(HPM) irradiated by: HL and LED. Four groups (n = 10) were divided according to the bleaching gel and light source. The results were submitted to the analysis of variance and Tukey test (p < 0.05). The mean values and standard deviations of the temperature increase inside the chamber pulp with HL were 4.4 ± 2.1 °C using HP and 4.5 ± 1.2 °C using HPM; while in LED groups, were 1.4 ± 0.3 °C to HP, and 1.5 ± 0.2 °C using HPM. For all surface temperatures, the maximum variation of the groups irradiated with HL was 6.5 ± 1.5 °C to HP and 7.5 ± 1.1 °C using HPM; while for the groups using LED, were 2.8° ± 0.7 °C using HP, and 3 ± 0.8 °C for HPM. There were no statistical difference between the increase of pulp and superficial temperature between groups using the various gels (p < 0.05). Mean temperatures were significantly higher for groups using HL compared with those irradiated with LED (p < 0.05). Was investigated the variation of surface temperature and thus given the time-delay to hit the critical variation of temperature (5.5 °C for the pulp chamber and 10 °C for periodontal). Forty-five human inferior incisors were divided into 3 groups and submitted to dental bleaching using...(Complete abstract, click electronic access below) / Mestre
18

Avaliação in vitro da fotopolimerização de bráquetes vestibulares e linguais com arco de plasma, led e luz halógena /

Magno, Amanda Fahning. January 2008 (has links)
Orientador: Lídia Parsekian Martins / Banca: Mirian Aiko Nakane Matsumoto / Banca: Dirceu Barnabé Raveli / Resumo: O objetivo dessa pesquisa foi avaliar in vitro a fotopolimerização de bráquetes vestibulares e linguais utilizando o arco de plasma, o diodo emissor de luz (LED) e a luz halógena convencional em tempos diferentes. Dois artigos científicos foram redigidos e utilizados para a avaliação dos propósitos apresentados. Na análise por vestibular, não houve diferenças entre o uso da luz arco de plasma por 6 segundos, do LED por 10 segundos e da luz halógena por 40 segundos. A luz arco de plasma por 3 segundos e o LED por 5 segundos demonstraram resistências ao cisalhamento iguais entre si e significantemente menores em relação às da luz halógena (p<0,001). Os resultados do índice de adesivo remanescente (IAR) mostraram que a interface de fratura dente/bráquete ocorreu com maior freqüência em todos os grupos, entretanto, os dados não puderam ser avaliados estatisticamente em função da distribuição dos escores. Na análise por lingual, as três fontes de luz mostraram-se diferentes entre si (p<0,001). A luz arco de plasma em 6 segundos obteve a menor média de resistência ao cisalhamento, seguida do LED em 10 segundos, que por sua vez apresentou menor média em relação à luz halógena em 40 segundos. O teste quiquadrado demonstrou não haver diferença significativa nos escores do IAR quando empregados os diferentes tipos de luz. Foi concluído, por vestibular, que a luz arco de plasma e o LED podem ser utilizados por tempos reduzidos em relação à luz halógena, sem perda de resistência ao cisalhamento, mas com limites para esta redução. Nos testes por lingual, a luz arco de plasma obteve resistências menores que o LED, o qual demonstrou resistências menores que a luz halógena, porém, estas diferenças não afetaram o padrão de descolagem. / Abstract: The objective of this in vitro study was to evaluate the variation of temperature and Knoop microhardness on enamel surface during the bleaching process whith 35% hydrogen peroxide under irradiation by halogen light whit the wavelength of 400 to 500nm (HL), LED whit the wavelength of 460 to 480nm and high intensity diode laser LED whit the wavelength of 810nm (LD) on extracted human teeth. Initially were investigated the variation of surface temperature (infrared thermography) and the temperature of the interior of the pulp chamber (thermocouples) in human mandibular incisors when subjected to dental bleaching with 35% hydrogen peroxide in the colors red (HP) and green(HPM) irradiated by: HL and LED. Four groups (n = 10) were divided according to the bleaching gel and light source. The results were submitted to the analysis of variance and Tukey test (p < 0.05). The mean values and standard deviations of the temperature increase inside the chamber pulp with HL were 4.4 ± 2.1 °C using HP and 4.5 ± 1.2 °C using HPM; while in LED groups, were 1.4 ± 0.3 °C to HP, and 1.5 ± 0.2 °C using HPM. For all surface temperatures, the maximum variation of the groups irradiated with HL was 6.5 ± 1.5 °C to HP and 7.5 ± 1.1 °C using HPM; while for the groups using LED, were 2.8° ± 0.7 °C using HP, and 3 ± 0.8 °C for HPM. There were no statistical difference between the increase of pulp and superficial temperature between groups using the various gels (p < 0.05). Mean temperatures were significantly higher for groups using HL compared with those irradiated with LED (p < 0.05). Was investigated the variation of surface temperature and thus given the time-delay to hit the critical variation of temperature (5.5 °C for the pulp chamber and 10 °C for periodontal). Forty-five human inferior incisors were divided into 3 groups and submitted to dental bleaching using HP and activated by HL,...(Complete abstract, click electronic access below) / Mestre
19

Penetração de peróxido de hidrogênio 38% no interior da câmara pulpar de dentes bovinos e humanos com ou sem restauração submetidos ao clareamento externo /

Camargo, Samira Esteves Afonso. January 2005 (has links)
Orientador: Márcia Carneiro Valera / Banca: Antonio Carlos Bombana / Banca: Claudio Antonio Talge Carvalho / Resumo: Acredita-se que a penetração de peróxido de hidrogênio através do esmalte e dentina pode causar danos à polpa. A proposta deste trabalho foi avaliar a quantidade de peróxido de hidrogênio no interior da câmara pulpar de dentes bovinos e humanos com ou sem restauração, após clareamento pela técnica de consultório. Os dentes foram seccionados 3mm à junção amelo-cementária e divididos em dois grupos: A (setenta terceiros molares humanos) e B (setenta incisivos laterais bovinos) que foram subdivididos em: A1 e B1 restaurados com resina composta (Esthetic-X, Dentsply), A2 e B2 com CIV (Vidrion-R, SSWhite), A3 e B3 com CIV modificado por resina (CIV-MR) (Vitremer, 3M); A4, A5, B4 e B5 não foram restaurados. No interior da câmara pulpar de todos os dentes foi colocado tampão acetato. Os subgrupos A1 a A4 e B1 a B4 foram expostos ao peróxido de hidrogênio 38% (Opalescence XtraBoost, Ultradent) por 40 min. Os subgrupos A5 e B5 permaneceram em água deionizada por 40 min. O tampão acetato foi transferido a um tubo de ensaio reagindo com corante violeta leucocristal e peroxidase. A densidade óptica da solução foi avaliada em espectrofotômetro, os valores de absorbância convertidos em microgramas de peróxido e submetidos aos testes de Dunnett, Kruskal-Wallis, ANOVA e Tukey (5%). Verificou-se maior penetração de peróxido nos dentes bovinos (0,79l0,61æg) e humanos (2,27l0,41æg) restaurados com CIV-MR. A penetração do agente clareador foi maior em dentes humanos para qualquer situação experimental. Concluiu-se que a penetração de peróxido depende do material restaurador e que dentes humanos são mais susceptíveis à penetração do agente clareador para o interior da câmara pulpar do que dentes bovinos. / Abstract: It is believe that externally applied bleachings agents could penetrate into the pulp chamber.This study was conducted to evaluate pulp chamber penetration of peroxide bleaching agent in human and bovine teeh, after office bleach technique. All the teeth were sectioned 3mm apical of the cemento-enamel junction and were divided into 2 groups: A (70 third human molars) and B (70 bovine lateral incisor) that were subdivided in: A1 and B1 restored using composite resin (Esthetic-X, Dentsply), A2 and B2 using glass ionomer cement (Vidrion-R, SSWhite), A3 and B3 using resin-modified glass ionomer cement (Vitremer, 3M); A4, A5, B4 and B5 were not restored. Acetate buffer was placed in the pulp chamber and the treatment agent was applied for 40 min as follow: A1 to A4 and B1 to B4 38% hydrogen peroxide exposure and A5 and B5 immersion into distilled water. The buffer solution was transferred to a glass tube where leuco crystal violet and horseradish peroxidase were added, producing a blue solution. The optical density of the blue solution was determined determined by spectrophotometer and converted into microgram equivalents of hydrogen peroxide. Data were submitted to ANOVA and Dunnett, Kruskal-Wallis, and Tukey tests (5%). A higher level of hydrogen peroxide penetrated into the pulp chamber in resin-modified glass ionomer cements groups, bovine (0,79l0,61æg) and human (2,27l0,41æg). The bleaching agent penetration was higher in human teeth for any experimental situation. The penetration of the hydrogen peroxide depend on restorative materials and that human teeth are more susceptible to penetration of bleaching agent into the pulp chamber than bovine teeth. / Mestre

Page generated in 0.0859 seconds