• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 1
  • Tagged with
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo biomecânico comparativo entre novo sistema de bloqueio (PAX) e sistema convencional de bloqueio (Synthes) em ensaios de arrancamento e teste de quatro pontos / Biomechanical study comparing new locking plate system (PAX) and conventional locking plate system (Synthes) in pullout and four points test.

Cavalcanti, Renato Albuquerque de Oliveira 20 January 2015 (has links)
Os materiais utilizados nas osteossínteses passam constantemente por avanços tecnológicos. Um dos mais recentes dispositivos é a chamada placa bloqueada, suas principais indicações são fraturas com alto grau de cominução, fraturas que não exigem uma redução anatômica, ossos osteopenicos, por exemplo, acometidos pela osteoporose, entre outras. Atualmente novos modelos de placas com bloqueio estão sendo desenvolvidos, onde a interface do parafuso e a placa são feito pela deformação do orifício, com a vantagem da instalação do parafuso em diversos ângulos. O presente projeto tem por objetivo estudar comparativamente a diferença entre os dois tipos de interface parafuso placa, como também realizar teste de quatro pontos comparando o sistema novo de bloqueio com o sistema convencional de bloqueio. Realizamos ensaios de arrancamento com sistema convencional de bloqueio (Synthes) e com o novo sistema de bloqueio (PAX) em parafusos 2,0mm; 2,4mm; 2,7mm e 3,5mm. Em todos os grupos testados o sistema convencional de bloqueio foi mais resistente e apresentou diferença significativa estatisticamente, teste de Mann- Witney (p< 0,05). Os valores de P obtidos foram: sistema 2.0mm p = 0,008; sistema 2.4 mm p= 0,008; sistema 2.7 mm p= 0,016; sistema 3.5 mm p= 0,008. No teste de 4 pontos utilizamos 20 placas da marca Synthes (sistema convencional de bloqueio) e 20 da marca PAX (novo sistema de bloqueio) e o sistema convencional de bloqueio se mostrou novamente mais resistente com diferença significativa. Os valores de P obtidos foram: sistema 2.0mm p = 0,008; sistema 2.4 mm p= 0,008; sistema 2.7 mm p= 0,008; sistema 3.5 mm p= 0,008. Conclui-se que o sistema convencional de bloqueio se mostrou mais resistente tanto no teste de arrancamento quanto no teste de flexão de quatro pontos. / The materials used in osteosynthesis constantly technological advances. One of the most recent devices is called the locking plate, its main indications are fractures with a high degree of comminution, fractures which do not require anatomical reduction, osteopenic bones, for example, affected by osteoporosis, among others. Currently new locking plate designs are being developed, where the screw interface and the plate are made by deformation of the hole, with the installation of the advantage screw at various angles. This study aims to compared the difference between the two types of interface screw - plate but also perform four-point test comparing the new locking system with the conventional system lock. Pullout tests conducted with conventional locking system (Synthes) and the new locking system (PAX) by screws 2.0mm; 2.4mm; 2.7mm and 3.5mm. In all groups tested the conventional system of blockade was stronger and showed a statistically significant difference, Mann-Witney test (p <0.05). P values were obtained: System 2.0mm P = 0.008; system 2.4 mm p = 0.008; System 2.7 mm p = 0.016; system 3.5 mm p = 0.008. In test points 4 used 20 Synthes plate mark (conventional blocking system) and 20 brand PAX (new locking system), the conventional locking system again showed a significant difference resistant. P values were obtained: System 2.0mm P = 0.008; system 2.4 mm p = 0.008; system 2.7 mm p = 0.008; system 3.5 mm p = 0.008. It follows that the conventional locking system has proved much more resistant peel test as in the four point bending test.
2

Ensaios biomecânicos de placas bloqueadas: comportamento dos parafusos bloqueados em diferentes angulações submetidos ao teste de arrancamento e influência do preenchimento dos orifícios médios na resistência ao teste de flexão / Biomechanical analysis of locking plates evaluating the influence of screw angulation and screw placement in center position of bridging plate

Tatiana Casimiro Mariani 16 November 2010 (has links)
A utilização de placas bloqueadas e suas vantagens biomecânicas na redução de fraturas cominutivas de ossos longos em cães já foram descritas por diversos autores. O presente trabalho teve como objetivo avaliar diferentes configurações de placa bloqueadas submetidas a dois diferentes testes biomecânicos, um de flexão em quatro pontos para avaliar a influencia do preenchimento dos orifícios centrais na resistência a flexão da placa bloqueada com função de placa de apoio. O outro teste avaliou a força máxima ao arrancamento de dois diferentes tipos de placas, um com todos os orifícios perpendiculares e outro com os orifícios angulados alternadamente lateral e medialmente em relação ao eixo longitudinal da placa. Para cada teste formou-se dois grupos com dez corpos de prova cada. Não houve diferença estatística no resultado obtido no teste de flexão, a resistência a flexão do grupo com preenchimentos dos orifícios centrais foi maior em relação ao grupo sem preenchimento, porem sem significância. Já no teste de arrancamento o grupo de placas com orifícios angulados obteve um valor de forma máxima de arrancamento significantemente superior em relação ao grupo com orifícios perpendiculares em relação ao eixo longitudinal da placa. Concluiu-se que não há influencia na resistência da placa de apoio com o preenchimento dos orifícios centrais da placa bloqueada e que a configuração de placa com os orifícios angulados se mostrou mais resistente ao arrancamento. / The feasibility of locking plates and their biomechanical advantages in comminuted fractures are well known. The objective of this study was to evaluate different locking plate´s configurations submitted to a four point´s flexion test and pull out test. The flexion test evaluated the influence of screws in center position in bridging plate, the pull out test compared relative to pull out strength locking plates using parallel locking screws or angulated locking screws. For each biomechanical assay two groups of ten test materials were formed. The results found no statistical differences relative to flexion resistance in the groups with and without central screws. Relative to pull out test the group with angulated screws showed higher values of maximum pull out strength when compared with the perpendicular screws, the data were statistically significant. We concluded that there was no improvement in the resistance of bridging plate with the use of central screws, but the use of angulated screws showed a greater resistance to pull out when compared to parallel screws.
3

Ensaios biomecânicos de placas bloqueadas: comportamento dos parafusos bloqueados em diferentes angulações submetidos ao teste de arrancamento e influência do preenchimento dos orifícios médios na resistência ao teste de flexão / Biomechanical analysis of locking plates evaluating the influence of screw angulation and screw placement in center position of bridging plate

Mariani, Tatiana Casimiro 16 November 2010 (has links)
A utilização de placas bloqueadas e suas vantagens biomecânicas na redução de fraturas cominutivas de ossos longos em cães já foram descritas por diversos autores. O presente trabalho teve como objetivo avaliar diferentes configurações de placa bloqueadas submetidas a dois diferentes testes biomecânicos, um de flexão em quatro pontos para avaliar a influencia do preenchimento dos orifícios centrais na resistência a flexão da placa bloqueada com função de placa de apoio. O outro teste avaliou a força máxima ao arrancamento de dois diferentes tipos de placas, um com todos os orifícios perpendiculares e outro com os orifícios angulados alternadamente lateral e medialmente em relação ao eixo longitudinal da placa. Para cada teste formou-se dois grupos com dez corpos de prova cada. Não houve diferença estatística no resultado obtido no teste de flexão, a resistência a flexão do grupo com preenchimentos dos orifícios centrais foi maior em relação ao grupo sem preenchimento, porem sem significância. Já no teste de arrancamento o grupo de placas com orifícios angulados obteve um valor de forma máxima de arrancamento significantemente superior em relação ao grupo com orifícios perpendiculares em relação ao eixo longitudinal da placa. Concluiu-se que não há influencia na resistência da placa de apoio com o preenchimento dos orifícios centrais da placa bloqueada e que a configuração de placa com os orifícios angulados se mostrou mais resistente ao arrancamento. / The feasibility of locking plates and their biomechanical advantages in comminuted fractures are well known. The objective of this study was to evaluate different locking plate´s configurations submitted to a four point´s flexion test and pull out test. The flexion test evaluated the influence of screws in center position in bridging plate, the pull out test compared relative to pull out strength locking plates using parallel locking screws or angulated locking screws. For each biomechanical assay two groups of ten test materials were formed. The results found no statistical differences relative to flexion resistance in the groups with and without central screws. Relative to pull out test the group with angulated screws showed higher values of maximum pull out strength when compared with the perpendicular screws, the data were statistically significant. We concluded that there was no improvement in the resistance of bridging plate with the use of central screws, but the use of angulated screws showed a greater resistance to pull out when compared to parallel screws.
4

Subprodutos da fresagem femoral ou osso esponjoso autógeno na osteossíntese femoral com hastes bloqueadas em cães / Femoral intramedullary reaming byproducts or autogenous cancellous bone in femoral osteosynthesis with interlocking nails in dogs

Silva, Fernanda Souza Barbosa da 23 February 2012 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / The aim of this research was to evaluate the interlocking nails technique in femoral fractures in dogs and evaluate the use of femoral intramedullary reaming byproducts as an adjuvant to bone healing. Twelve dogs, weighing between 15 and 18 kg, were randomly distributed in three groups according to the type of graft used in the fracture denominated I (control- untreated), II (the byproducts of femoral intramedullary reaming) and III(autogenous cancellous bone). Transverse osteotomy was performed in the middle portion of the femur and posterior osteosynthesis with inrelocking nails. After was carried out the grafting with by-products of intramedullary reaming or autogenous cancellous bone in sufficient quantity to fill the surface of the fracture. In order to compare the performance of the groups treatment were performed radiographic evaluations at 15, 30, 60 and 90 days postoperatively (PO), and clinical evaluation of the daily march up to the 7th postoperative day, and after weekly until the 60th days after surgery. The radiographic analysis revealed that at 30 postoperatively day the mean scores of consolidation in the dogs of the group that received grafts of intramedullary reaming by-products were higher than the other groups. At 45 and 60 postoperative days radiographic images also indicated the superiority of group II in relation to other groups. Clinical evaluation of the march on the 15th postoperative day showed the best performance of the dogs treated with grafting of femoral reaming by-products. 75% of these animals were in grade V of lameness. There was no statistical difference between the grafting of femoral intramedullary reaming byproducts and autogenous cancellous bone in relation to radiographic consolidation scores and degrees of lameness, at different times after surgery. The interlocking nails were considered an efficient method for osteosynthesis of femoral diaphyseal fractures in dogs, without alterations or inconvenience in postoperative period. The grafting of femoral intramedullary reaming byproducts proved to be a viable and effective adjuvant in healing bone fractures of long bones of dogs and we recommend this technique to be evaluated in dogs from traumatic fractures. / O objetivo desta pesquisa foi avaliar a técnica de hastes bloqueadas na osteossíntese de fraturas femorais em cães e avaliar o uso de subprodutos da fresagem intramedular femoral como adjuvante na cicatrização óssea. Foram utilizados 12 cães, pesando entre 15 e 18 kg, distribuídos aleatoriamente em três grupos iguais de acordo com o tipo de enxerto utilizado no foco da fratura, denominados de I (controle não tratado), II (subprodutos da fresagem intramedular femoral) e III (osso esponjoso autógeno). Foi realizada osteotomia transversa na porção média da diáfise femoral e posterior osteossíntese com hastes bloqueadas. Após realizou-se a enxertia de subprodutos da fresagem intramedular ou de osso esponjoso autógeno em quantidade suficiente para preencher a superfície do foco da fratura. Para comparar o desempenho dos grupos tratados, foram realizadas avaliações radiográficas nos períodos de 15, 30, 60 e 90 dias de pós-operatório (PO), e avaliação clínica da marcha diária até o 7º dia de PO, e após semanalmente até os 60 dias de PO. A análise radiográfica revelou que aos 30 dias de PO a média dos escores de consolidação no grupo que recebeu enxerto dos subprodutos fresagem intramedular foi superior à dos outros grupos. Aos 45 e 60 dias de PO as imagens radiográficas também indicaram a superioridade do Grupo II em relação aos demais grupos. A avaliação clínica deambulatória no 15º dia de PO evidenciou o melhor desempenho dos cães tratados com enxerto de subprodutos da fresagem femoral, dos quais 75% dos animais encontravam-se em grau V de claudicação. Não foi encontrada diferença estatística entre a enxertia de subprodutos da fresagem intramedular femoral e de osso esponjoso autógeno com relação aos escores de consolidação radiográfica e graus de claudicação, nos diferentes tempos de PO. As hastes bloqueadas foram consideradas um método eficiente para a osteossíntese de fraturas femorais diafisárias em cães, não possuindo alterações ou inconvenientes no pós-operatório. O enxerto de subprodutos da fresagem intramedular femoral revelou-se uma opção viável e eficiente de adjuvante cicatricial ósseo em fraturas de ossos longos de cães, recomendando-se sua avaliação na rotina clínica.
5

Estudo biomecânico comparativo entre novo sistema de bloqueio (PAX) e sistema convencional de bloqueio (Synthes) em ensaios de arrancamento e teste de quatro pontos / Biomechanical study comparing new locking plate system (PAX) and conventional locking plate system (Synthes) in pullout and four points test.

Renato Albuquerque de Oliveira Cavalcanti 20 January 2015 (has links)
Os materiais utilizados nas osteossínteses passam constantemente por avanços tecnológicos. Um dos mais recentes dispositivos é a chamada placa bloqueada, suas principais indicações são fraturas com alto grau de cominução, fraturas que não exigem uma redução anatômica, ossos osteopenicos, por exemplo, acometidos pela osteoporose, entre outras. Atualmente novos modelos de placas com bloqueio estão sendo desenvolvidos, onde a interface do parafuso e a placa são feito pela deformação do orifício, com a vantagem da instalação do parafuso em diversos ângulos. O presente projeto tem por objetivo estudar comparativamente a diferença entre os dois tipos de interface parafuso placa, como também realizar teste de quatro pontos comparando o sistema novo de bloqueio com o sistema convencional de bloqueio. Realizamos ensaios de arrancamento com sistema convencional de bloqueio (Synthes) e com o novo sistema de bloqueio (PAX) em parafusos 2,0mm; 2,4mm; 2,7mm e 3,5mm. Em todos os grupos testados o sistema convencional de bloqueio foi mais resistente e apresentou diferença significativa estatisticamente, teste de Mann- Witney (p< 0,05). Os valores de P obtidos foram: sistema 2.0mm p = 0,008; sistema 2.4 mm p= 0,008; sistema 2.7 mm p= 0,016; sistema 3.5 mm p= 0,008. No teste de 4 pontos utilizamos 20 placas da marca Synthes (sistema convencional de bloqueio) e 20 da marca PAX (novo sistema de bloqueio) e o sistema convencional de bloqueio se mostrou novamente mais resistente com diferença significativa. Os valores de P obtidos foram: sistema 2.0mm p = 0,008; sistema 2.4 mm p= 0,008; sistema 2.7 mm p= 0,008; sistema 3.5 mm p= 0,008. Conclui-se que o sistema convencional de bloqueio se mostrou mais resistente tanto no teste de arrancamento quanto no teste de flexão de quatro pontos. / The materials used in osteosynthesis constantly technological advances. One of the most recent devices is called the locking plate, its main indications are fractures with a high degree of comminution, fractures which do not require anatomical reduction, osteopenic bones, for example, affected by osteoporosis, among others. Currently new locking plate designs are being developed, where the screw interface and the plate are made by deformation of the hole, with the installation of the advantage screw at various angles. This study aims to compared the difference between the two types of interface screw - plate but also perform four-point test comparing the new locking system with the conventional system lock. Pullout tests conducted with conventional locking system (Synthes) and the new locking system (PAX) by screws 2.0mm; 2.4mm; 2.7mm and 3.5mm. In all groups tested the conventional system of blockade was stronger and showed a statistically significant difference, Mann-Witney test (p <0.05). P values were obtained: System 2.0mm P = 0.008; system 2.4 mm p = 0.008; System 2.7 mm p = 0.016; system 3.5 mm p = 0.008. In test points 4 used 20 Synthes plate mark (conventional blocking system) and 20 brand PAX (new locking system), the conventional locking system again showed a significant difference resistant. P values were obtained: System 2.0mm P = 0.008; system 2.4 mm p = 0.008; system 2.7 mm p = 0.008; system 3.5 mm p = 0.008. It follows that the conventional locking system has proved much more resistant peel test as in the four point bending test.
6

Valoración de la efectividad del tratamiento quirúrgico mediante placa volar frente al tratamiento conservador en la fractura articular de radio distal en mayores de 60 años

Martínez Méndez, Daniel 06 July 2018 (has links)
En el primer trabajo se diseñó un estudio prospectivo aleatorizado. El objetivo era comparar los resultados entre tratamiento conservador (reducción cerrada e inmovilización enyesada) y quirúrgico (reducción abierta y fijación interna con placa volar) en pacientes de edad con fractura de radio distal. Método: 97 pacientes mayores de 60 años fueron aleatorizados a tratamiento conservador (47 pacientes) o quirúrgico (50 pacientes). A lo largo de 2 años postoperatorios fueron evaluados con la escala funcional PRWE (patient-rated wrist evaluation), el cuestionario DASH (Disability Arm, Shoulder and Hand), dolor, rango de movilidad de la muñeca, fuerza del puño y parámetros radiográficos. Resultados: los resultados funcionales y de calidad de vida fueron significativamente mejores tras el tratamiento quirúrgico con placa volar que con el conservador. Se observó que la restauración de la superficie articular, ángulo de inclinación radial y varianza cubital afectaban a los resultados, pero no el escalón articular. El 25% de los pacientes con tratamiento conservador tuvieron pérdida secundaria de la reducción. Conclusión: la placa quirúrgica resultaba en mejor resultado que el tratamiento conservador para pacientes de edad con fractura intraarticular del radio distal. En el segundo trabajo, el objetivo era evaluar la capacidad de la placa volar bloqueada para mantener los parámetros radiográficos a lo largo del tiempo en pacientes de edad con fractura compleja intraarticular del radio distal. Método: cohorte prospectiva de 66 pacientes consecutivos, con edad media de 68 años (rango 60-81) y fractura tipo C de AO tratados con placa volar bloqueada. Se realizaron mediciones radiográficas pre y postoperatorias en cada visita. La valoración clínica se realizó mediante la escala PRWE (Patient-Rated Wrist Evaluation), el cuestionario DASH (Disabilities Arm, Shoulder and Hand), movilidad de la muñeca y fuerza del puño. Resultados: el seguimiento postoperatorio medio fue de 31 meses (rango, 24-47). Los parámetros más difíciles de restaurar con la cirugía fueron el ángulo radial volar y la altura radial, mientras que la inclinación radial y varianza cubital se restauró en la mayoría de los pacientes. Hubo una significativa pérdida de reducción en los primeros 4 meses respecto al ángulo radial volar y altura radial, y sin cambios a partir de dicha fecha. Al seguimiento final, el 50,1% de los pacientes tenían los parámetros radiográficos restaurados de acuerdo a la muñeca contralateral, pero el 83,3% tuvieron todos los parámetros dentro del rango funcional. Conclusión: la fijación con placa volar bloqueada para fracturas intraarticulares del radio distal fue un efectivo procedimiento para obtener resultados funcionales satisfactorios. Aunque hubo pérdida de reducción precoz del ángulo radial volar y altura radial, la placa volar fue capaz de mantener a lo largo del tiempo la estabilización de la fractura con parámetros radiográficos dentro del rango funcional en estos pacientes de edad avanzada.

Page generated in 0.0547 seconds