Spelling suggestions: "subject:"bondstrength"" "subject:"bandstrength""
341 |
Efeito do retardamento da polimerização da base de cimento de ionômero de vidro modificado por resina na resistência adesiva em restaurações de resina composta / Effect of delaying photoativation of resin modified glass-ionomer cement used as a liner on the bond strength of composite resin restorationsLeslie Caroll Casas Apayco 22 April 2009 (has links)
Durante o processo inicial da reação de presa, o cimento de ionômero de vidro modificado por resina (CIVMR) apresenta baixo módulo de elasticidade, característica importante quando utilizado como base de restaurações com resina composta, por diminuir o estresse de contração de polimerização nas paredes cavitárias. O presente estudo teve como objetivo analisar a influência da técnica de polimerização de uma base CIVMR (VitrebondTM) por resina na interface dente/restauração de resina composta, através de teste de microtração e análise em microscopia confocal. Foram utilizados 30 dentes molares humanos hígidos extraídos, nos quais foram confeccionadas cavidades padronizadas em sua face oclusal (5mm de comprimento x 3mm de largura x 4,5mm profundidade). O sistema adesivo utilizado AdperTM Single Bond 2 foi marcado previamente com Rodamina B (0,16mg/ml), para possibilitar a análise em microscópio confocal. Os dentes foram divididos em 3 grupos: Grupo 1 (controle): base de CIVMR VitrebondTM + fotoativação + sistema adesivo + resina composta FiltekTM Z250; Grupo 2: base de CIVMR VitrebondTM + sistema adesivo + fotoativação por 30 segundos simultânea dos dois materiais + resina composta FiltekTM Z250; Grupo 3: base de CIVMR por resina VitrebondTM + tempo de espera de 60 segundos + fotoativação + sistema adesivo + resina composta FiltekTM Z250. Após a restauração, os dentes permaneceram em água deionizada em estufa a 37 ºC por 24 horas. Em seguida, foram seccionados com disco de diamante em fatias de aproximadamente 0,8mm no sentido vestíbulo-lingual. Uma fatia de cada dente foi separada aleatoriamente para análise da presença de fendas na interface dentina/resina composta em microscopia confocal. As demais fatias foram seccionadas para a confecção de palitos, para os testes de microtração. Os resultados de resistência de união foram submetidos à análise de variância a um critério ANOVA a 5% e teste de qui-quadrado para as variáveis de presença de fendas marginais e tipo de fratura resultante (p<0,05). Não houve diferença estatisticamente significante entre os três grupos (p=0,644) com relação à resistência adesiva e tipo de fratura, predominando a fratura do tipo adesiva para todos os grupos. Quanto à presença de fendas marginais internas, foi evidenciada sua presença nos grupos 2 e 3, sem diferença estatisticamente significante entre os três grupos testados (p=0,082). Conclui-se, portanto, que a técnica de polimerização da base de cimento de ionômero de vidro modificado por resina não influencia na resistência adesiva da interface dente/restauração de resina composta. / During the initial process of setting reaction, the resin-modified glass-ionomer cement (RMGIC) shows low modulus of elasticity, which is an important characteristic when RMGIC is used as a liner in resin composites restorations, because it decreases the polymerization shrinkage stress in cavity walls. The aim of this study was to analyze the influence of polymerization techniques of resin-modified glass-ionomer cement used as a liner on the adhesive interface dentin/resin by microtensile test and confocal microscopic analysis. Standardized occlusal cavity preparations (5mm length x 3mm wide x 4.5mm depth) were prepared in 30 human extracted molars. For the analysis at the confocal microscope, the adhesive system AdperTM Single Bond 2 was previously marked with rodhamine B (0.16mg/ml). The tooth were divided into three groups: Group 1 (control): RMGIC liner VitrebondTM + photoactivation for 30 seconds + adhesive system + resin composite Filtek TM Z250; Group 2: RMGICs liner VitrebondTM + adhesive system + simultaneous photoactivation of both materials + resin composite FiltekTM Z250; Group 3: RMGICs liner VitrebondTM+ 60 seconds delay time + photoativation for 30 seconds + adhesive system + resin composite FiltekTMZ250. Specimens were stored at 37ºC in deionized water for 24 hours. After this period, tooth was sectionated in 0.8mm slices (buco-lingual). One slice of each tooth was randomly selected for confocal microscopy for analysis of the interface resin/dentin. The other slices were sectionated in sticks (mesio-distal) for microtensile test. One-way ANOVA (p<0.05) showed no significant statistical difference among groups 1, 2 and 3 (p=0.644). Quisquare test showed no significant statistical difference of type of fracture (adhesive fracture was predominant) and presence of gap at the interface dentin/resin among groups. (p=0.082). It can be concluded, that polymerization technique of resin-modified glassionomer cement (RMGIC) did not influence bond strength and dentin/resin composite interface.
|
342 |
"Influência do método de remoção de cárie na resistência adesiva de um sistema autocondicionante" / Microtensile bond strength of self-etching adhesives to caries-affected dentineArlene Tachibana 10 June 2005 (has links)
Novos métodos de remoção do tecido cariado tem sido propostos, entre eles a utilização de lasers, abrasão a ar e químico-mecânico. Este trabalho teve o objetivo de avaliar a influência de diferentes métodos de remoção de cárie na resistência de união de um sistema adesivo autocondicionante. Cinquenta molares humanos cariados extraídos foram desgastados para expor uma superfície plana onde a lesão de cárie se encontrava rodeada por dentina hígida. Os dentes foram divididos em 05 grupos (n=10), com um total de 50 dados, de acordo com o método de remoção do tecido cariado, como segue: G1 - sem remoção; G2 - remoção com lixa; G3 broca de aço esférica em baixa rotação; G4 - laser de Er, Cr: YSGG e G5 - Carisolv. Procedimentos adesivos foram realizados com o sistema autocondicionante (Clearfil SE Bond Kuraray Japão), de acordo com as instruções do fabricante. Um cilíndro de resina composta (Z250- 3M do Brasil) foi construído sobre a superfície com o sistema adesivo e estocados em água (24 horas a 37 0 C). Os corpos de prova foram seccionados verticalmente para obtenção de fatias e em seguida confeccionadas ampulhetas em dentina infectada, afetada e sadia, com área aproximada de 1mm 2. As ampulhetas foram montadas em dispositivos de micro-tração e ensaiados na máquina de teste (Mini-Instron) com velocidade de 0,5mm/min. Os resultados obtidos mostraram que existem diferenças estatisticamente significantes entre os substratos sadio e infectado para o grupo G1e sadio e afetado para os grupos G2, G3 e G5. Em dentina sadia, o método utilizado em G3 resultou em valores de adesão superiores com relação a G4 e G2 foi estatisticamente superior com relação a todos os grupos. Os métodos de remoção de dentina infectada utilizados em G2 e G3 resultaram em valores de adesão superiores com relação a G1(dentina infectada). Desta forma podemos concluir que: o tipo de substrato influencia significativamente na resistência adesiva do sistema autocondicionante testado. A adesão à dentina sadia é mais efetiva que à dentina infectada (G1) e à dentina afetada obtida após remoção do tecido infectado com lixa (G2), broca (G3) e Carisolv (G5). Entretanto, para o laser de Er,Cr:YSGG (G4) não houve evidência amostral que sugerisse maior efetividade na adesão da dentina sadia com relação à dentina afetada. A adesão em dentina sadia mostrou-se mais efetiva quando esta foi instrumentada com lixa. Porém, trata-se de um recurso laboratorial de padronização dos espécimes. A utilização da broca de aço resultou em uma superfície mais favorável a adesão, quando comparada à obtida após irradiação com laser de Er, Cr: YSGG, em dentina sadia. A adesão em dentina infectada é pobre, ficando ressaltada a necessidade da remoção deste tipo de dentina, preferencialmente com lixa ou broca, previamente a adesão com sistema autocondicionante. Para os demais métodos de remoção da dentina infectada testados, não houve evidência amostral para se detectar a existência de diferenças significantes na resistência adesiva em dentina afetada. / New methods for carious dentine removal have been proposed, such as, lasers and chemo-mechanical. This in vitro study aimed to evaluate the influence of caries removal methods (steel burs, Er, Cr: YSGG laser and Carisolv) on microtensile bond strength of self-etching adhesive systems. 50 extracted carious human molars were ground to expose flat surfaces where caries lesion was surrounded by normal dentine. Teeth were divided into 5 groups (n=10), with 50 original data, according to the removal method used: G1 - no removal; G2 - abrasive paper, G3 - steel burs; G4 Er, Cr: YSGG laser (79, 61 J/cm 2 ) and G5 Carisolv. Surfaces were bonded with Clearfil SE Bond, according to manufacturers instructions. A crown was built up using composite resin (Z250- 3M Brasil). After storage in water (24 h, 37 0 C), teeth were vertically serially sectioned into slices and trimmed into an hourglass shape with about of 1mm 2 area at the adhesion interface, that contained either infected, caries affected and normal dentine. Samples were tested in tension in a Instron machine at 0,5mm/min. Results showed that there is a significant difference between tested groups (p< 0.005). Significantly lower results were found for caries infected dentin when compared to normal dentin values (G1). A significant difference was also found when caries affected and normal dentin were compared (G2, G3, G5). In normal dentin, G2 showed better bond strenght than another groups and G4 showed lower results than G3. G2 and G3 caries infected dentin removal methods showed better bond strength than the other groups when compared with G1 (caries infected dentin). The results indicated that: bond strength of a self-etching system to normal dentin was better than to caries infected (G1) and caries affected dentin after the use of abrasive paper (G2), round steel bur (G3) and Carisolv (G4). However, there was no difference between caries affected and normal dentin after the use of ErCr:YSGG laser (G4); abrasive paper is a laboratorial method to create smear layer and it was responsable for the best bond strength to normal dentin. The usage of Er, Cr: YSGG laser negatively altered adhesion of self-etching system on normal dentin when compared with round steel bur; infected dentin is not an adequate substrate for adhesion. Abrasive paper and round steel bur are the best caries infected dentin removal methods. There were no difference in bond strength to caries affected dentin when the other methods were used.
|
343 |
Efeito de um agente primer e de ciclos térmicos para cocção de porcelana na resistência de união adesiva entre alumina e cimento resinoso / Effect of a primer agent and thermal cycles for porcelain firing on the bond strength of resin cement to alumina.Renato Savi de Carvalho 11 September 2009 (has links)
Coroas cerâmicas apoiadas sobre infra-estruturas de alumina densamente sinterizada configuram-se como excelentes opções para a reabilitação protética em casos de exigência estética, contudo, o aumento do conteúdo cristalino inviabiliza seu condicionamento por ácidos deixando a maneira ideal de cimentá-las ainda desconhecida. Coroas Procera AllCeram apresentam, em sua face interna, micro irregularidades interessantes ao embricamento e adesão resinosa, dispensando manobras de condicionamento. Objetivo: O objetivo deste trabalho foi avaliar a influência de elevadas temperaturas (500ºC à 950ºC) necessárias à cocção da porcelana de revestimento, na textura superficial da alumina, bem como o papel de um agente primer (Ivoclar Vivadent) na força de adesão entre alumina e cimento resinoso. Material e métodos: Sessenta (60) cilindros de alumina (3,5mm X 16mm) com rugosidade superficial idêntica à dos copings Procera foram divididos em quatro grupos (n=15). Grupo 1): Espécimes não submetidos a variação térmica, sendo G1a Sem aplicação do primer e G1b Com aplicação do primer e Grupo 2): Espécimes submetidos aos ciclos térmicos para cocção da porcelana feldspática, sendo G2a Sem aplicação do primer e G2b Com aplicação do primer. Sobre os cilindros aplicou-se porção do cimento resinoso químico MultiLink Ivoclar. Os espécimes foram levados a uma máquina de ensaios Universal para teste de cisalhamento a uma velocidade de 0.5mm/min e os dados submetidos à análise de variância a um critério e teste de comparações múltiplas de Tukey. Resultados: A força de adesão para cada um dos grupos foi: G1a = 2.468 MPa; G1b = 4.265 MPa; G2a = 2.339MPa e G2b = 4.185 MPa. Diferenças significantes foram observadas entre os grupos: G1a X G1b; G1a X G2b; G1b X G2a e G2a X G2b. Conclusões: Ciclos térmicos não produziram alterações na micro-estrutura superficial da alumina, tampouco comprometeram sua adesão ao cimento. O agente primer aumentou a força de união entre alumina e cimento resinoso. Fraturas coesivas do agente cimentante foram observadas apenas em alguns espécimes primer-tratados. / High-strength alumina based ceramic crowns are widely used in dentistry due to their favorable esthetic, however, the large amount of crystalline contents jeopardizes their acid etching property and the ideal luting remains unclear. Procera AllCeram restorations exhibits on their intaglio surface micro irregularities optimizing the bonding to resin, with no need for additional conditioning procedures. Purpose: The aim of the present study was to evaluate the influence of high thermal cycles (500ºC to 950ºC) needed to porcelain firing on alumina´s intaglio surface, as well as, the role of a primer agent (Ivoclar Vivadent) on shear bond strength between alumina and resin cement. Material and Methods: Sixty alumina cylinders (3,5mm X 16mm) with intaglio roughness of the Procera AllCeram copings were randomly divided into four groups (n=15). Group 1) Samples no submitted to thermal cycles variation, were G1a - no primer application and G1b - primer treated and Group 2: Samples submitted to thermal feldspathic porcelain firing cycles, were G2a - specimens no primer treated and G2b - primer treated specimens. Over the cylinders top a self-cure resin cement (Multilink Ivoclar) portion was applied. The specimens were loaded to failure in shear mode using a universal testing machine at a crosshead speed of 0,5mm/min. Data were analyzed with one-way analysis of variance and Tukey´s multiple comparison test. Results: The shear bond strength for each group was: G1a = 2.468 MPa; G1b = 4.265 MPa; G2a = 2.339 MPa e G2b = 4.185 MPa. Significant difference was found between the groups G1a X G1b; G1a X G2b; G1b X G2a e G2a X G2b. Conclusions: Thermal cycles did not change alumina´s surface micro structure, besides did not compromised it´s bonding strength to resin cement. Primer agent enhanced shear bond strength between alumina and resin cement. Luting agent´s cohesive fractures were observed only in some primer treated specimens.
|
344 |
Resistência de união de um cimento resinoso a diferentes superfícies de alumina densamente sinterizada / Shear bond strenght of a resin cement to different surfaces of densely sintered aluminaJuan Rommel Medina Valdivia 20 June 2007 (has links)
O propósito deste estudo foi avaliar a resistência adesiva ao cisalhamento de um cimento resinoso à alumina densamente sinterizada testando o tratamento superficial feito pelo fabricante. O cimento utilizado foi o Multilink (Ivoclar Vivadent) e a alumina foi a Procera®Alumina (Nobel Biocare) constituída por 99,9 % de óxido de alumínio densamente sinterizado. Trinta e dois cilindros de alumina foram confeccionados pela Nobel Biocare, onde um dos extremos deste cilindro recebeu o tratamento superficial e o outro não. Para a aplicação do cimento resinoso sobre os cilindros de alumina, utilizou-se uma matriz de Teflon com um orifício central de 3,5mm de diâmetro por 3,0mm de profundidade. Foram determinados 4 grupos experimentais: Grupo 1 superfície sem tratamento; Grupo 2 superfície sem tratamento e com aplicação de adesivo; Grupo 3 - superfície com o tratamento realizado pelo fabricante; Grupo 4 superfície com tratamento realizado pelo fabricante e com adesivo. Após a aplicação do cimento nos 4 grupos, os espécimes foram armazenados em água deionizada a 37ºC durante 24h, sendo, em seguida, montados em uma máquina universal de ensaios para realização dos testes de resistência ao cisalhamento. Os resultados foram submetidos à análise de variância a dois critérios e ao teste de Tukey para comparação entre os grupos. A superfície tratada (grupo 3) apresentou valores significativamente maiores que todos os outros grupos. A presença do adesivo diminuiu a resistência adesiva quando aplicado na superfície tratada, mas não deu diferença significante quando aplicado na superfície sem tratamento. / The aim of this study was to investigate the shear bond strength between a resin cement and densely sintered alumina treated by the fabricant. The resin cement used was the Multilink (Ivoclar Vivadent) and the alumina the Procera®Alumina (Nobel Biocare) made with 99,9% of densely sintered aluminum oxide. Thirty two alumina cylinders were made by Nobel Biocare, and in one of the extremes was applied a own`s fabricant surface treatment. For the application of the cement, a Teflon matrix with a central hole (diameter of 3,5 mm and a height of 3,0 mm) was used. Four groups were created: Group 1 surface without treatment; Group 2 - surface without treatment and with adhesive; Group 3 surface with the own`s fabricant treatment; Group 4 - surface with the own`s fabricant treatment with adhesive. After the cement application, the specimens were stored in water at 37º C for 24 hours. Then the samples were placed in a universal testing machine for making the shear strength test. Statistical analysis was performed with two-way analysis of variance (ANOVA), and paired comparisons between groups were done with Tukey`s multiple comparison. Higher significant values were detected for Group 3 when compared with all the other groups. The adhesive decreased the shear bond strength when laid on the treated surface, and there were no difference when laid on the untreated surface.
|
345 |
Efeito da contaminação por saliva humana na interface adesiva: resistência de união, análise de camada híbrida e conversão de sistemas adesivos / Effect of human saliva contamination on adhesive interface: bond strength, hybrid layer analysis and conversion of adhesive systemsCarlos Andres Villavicencio Espinoza 03 July 2017 (has links)
Este estudo teve como objetivo analisar o efeito da contaminação por saliva humana na resistência de união (RU) da interface adesiva em dentina por microtração, nas características morfológicas da camada híbrida (CH) em microscopia confocal e no grau de conversão (GC) de 2 sistemas adesivos: Adper Single bond 2 (SB) e Single Bond® Universal (SU). Cento e oitenta dentes terceiros humanos hígidos foram divididos em 12 grupos (n=10), de acordo com o sistema adesivo utilizado, a presença de saliva e o tempo de armazenagem. Após o procedimento adesivo e aplicação da resina composta Filtek Z250, os dentes foram mantidos em água destilada em estufa a 37°C por 48 horas, 6 meses ou 12 meses antes de serem seccionados em palitos (0,8mm x 0,8mm, aproximadamente) para serem levados à máquina de ensaios universal Instron para os testes de microtração. Para à análise da interface adesiva em microscopia confocal de varredura a laser para verificação e mensuração de alterações internas na interface foram utilizados 60 dentes divididos em 6 grupos (n=10) de acordo com os tempos de 48 horas, 6 meses, e 12 meses respectivamente, empregando os sistemas adesivos (SB) e (SU). O efeito da presença de saliva também foi avaliado pelo grau de conversão dos adesivos, empregando-se espectroscopia de infravermelho transformada de Fourier empregando os sistema adesivos (SB) e (SU) com incorporação de saliva humana na sua composição (n=5) com concentrações 10%, 25% e 50% em vol. Para a comparação das variáveis: RU, (GC), espessura da CH, na presença de saliva e tempo de armazenamento foram utilizados os testes de Análise de Variância a três critérios e de comparações múltiplas de Tukey (p<0,05). Os valores de RU (MPa±dp: 48horas/6meses/1ano) foram: SB (43,53 ±6,0; 40,10±3,4; 38,59±5,4); SalSB (43,09±6,2; 39,86±6,6; 37,255,8); SU (42,98±4,3; 39,30±3,6; 40,44±5,7); Sal SU (44,39±4,2; 42,26±2,5; 38,26±5,7). Os Valores médios da CH (MPa±dp: 48horas/6meses/1ano) foram: SalSB (3,59±0,8; 3,59±1,0; 2,08±1,5). SalSU (1,26±0,5; 1,73±0,8; 1,07±0,3). Os valores de GC (MPa±dp: 10%/25%/50%vol) foram: SB (85,59±3,4; 49,68±12,8; 38,56±11,8); SU (85,52±3,3; 86,27±3,5; 57,82±11,1).Conclui-se, portanto, que a contaminação por saliva humana não interferiu na RU da interface dentina/resina composta após 48 horas, 6 meses e 12 meses. A morfologia da camada hibrida foi alterada pela presença da saliva nos períodos 6 e 12 meses,. O GC dos sistemas adesivos foi afetado pela presença de saliva após a polimerização imediata. Entretanto o fator tempo foi determinante para a deformação da interface dentina/resina para ambos os sistemas adesivos. / The objective of this study was to analyze the effect of human saliva contamination on bond strength of the dentin/adhesive interface, morphology of the hybrid layer by confocal microscopy and SEM analysis and degree of conversion of 2 adhesive systems: Adper Single bond 2 (SB) and Single Bond® Universal ( SU). One hundred and eighty healthy human third teeth were divided into 12 groups (n = 10), according to the adhesive system used, the presence of saliva and the storage time. After the adhesive procedure and placement of resin composite (Filtek Z250), the teeth were stored in distilled waterat 37 ° C for 48 hours, 6 months or 12 months before being cut into sticks (0.8mm x 0.8mm, approximately) to the microtensile strength tests. For the analysis of the adhesive interface in confocal microscopy of laser scanning for verification and measurement of internal interface changes, 60 teeth were used divided into 6 groups (n = 10) according to the storage time: 48 hours, 6 months, and 12 monthsand (SB) and (SU). The effect of the presence of saliva was also evaluated by the degree of conversion of the adhesives using Fourier transform infrared spectroscopy employing adhesive (SB) and (SU) systems incorporating human saliva in its composition (n = 5) with 10%, 25% and 50% vol. For the comparison of the variables: bond strength, degree of conversion, and hybrid layer thickness in the presence of saliva and storage time, the three criteria Variance Analysis and Tukey multiple comparisons tests (p <0.05) were used. The values of bond strength (MPa ± dp: 48hours / 6meses / year) were: SB (43.53 ± 6.0, 40.10 ± 3.4, 38.59 ± 5.4); SalSB (43.09 ± 6.2, 39.86 ± 6.6, 37.255.8); SU (42.98 ± 4.3, 39.30 ± 3.6, 40.44 ± 5.7); SU salt (44.39 ± 4.2, 42.26 ± 2.5, 38.26 ± 5.7). The mean values of hybrid layer thickness (MPa ± dp: 48hours / 6meses / year) were: SalSB (3.59 ± 0.8, 3.59 ± 1.0, 2.08 ± 1.5). SalSU (1.26 ± 0.5, 1.73 ± 0.8, 1.07 ± 0.3). The values of degree of conversion (MPa ± dp: 10% / 25% / 50% vol) were: SB (85.59 ± 3.4, 49.68 ± 12.8, 38.56 ± 11.8); (85.52 ± 3.3, 86.27 ± 3.5, 57.82 ± 11.1). It was therefore concluded that human saliva contamination did not interfere on bond strength of the dentin/adhesive interface after 48 hours, 6 months and 12 months. The morphology of the hybrid layer was altered by the presence of saliva after 6 and 12 months. The degree of conversion of adhesive systems was affected by the presence of saliva immediately after polymerization. However, the time factor was determinant for the dentine/resin interface deformation for both adhesive systems.
|
346 |
Influência da terapia endodôntica e do envelhecimento artificial acelerado na resistência de união de pinos de fibra de vidro à dentina intrarradicular / Influence of endodontic therapy and artificial accelerated aging on fibreglass post bond strength to intraradicular dentineSantana, Fernanda Ribeiro 28 May 2012 (has links)
Submitted by Luanna Matias (lua_matias@yahoo.com.br) on 2015-03-09T11:19:12Z
No. of bitstreams: 2
Tese - Fernanda Ribeiro Santana - 2012.pdf: 12111889 bytes, checksum: 84cf2d3d0d514483cc202fde5fa79301 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luanna Matias (lua_matias@yahoo.com.br) on 2015-03-09T14:09:39Z (GMT) No. of bitstreams: 2
Tese - Fernanda Ribeiro Santana - 2012.pdf: 12111889 bytes, checksum: 84cf2d3d0d514483cc202fde5fa79301 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-03-09T14:09:39Z (GMT). No. of bitstreams: 2
Tese - Fernanda Ribeiro Santana - 2012.pdf: 12111889 bytes, checksum: 84cf2d3d0d514483cc202fde5fa79301 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Previous issue date: 2012-05-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Aim: To evaluate in vitro the influence of root canal instrumentation techniques,
endodontic irrigants, endodontic sealers and artificial accelerated aging on
fibreglass post bond strength to bovine intraradicular dentine. Methodology:
Part 1. 120 bovine incisors were divided into 12 experimental groups (n=10)
resulting from the interaction among 3 study factors: root canal instrumentation
technique (RCPSS- root canal preparation with stainless steel instruments - KFile;
RCPNiTi- root canal preparation with K3 Nickel-Titanium instruments),
endodontic irrigant (NaOCl- 1% sodium hypochlorite; CHX- 2% chlorhexidine;
O3- 1.2% ozonated water) (in all samples 17% EDTA was used to remove the
smear layer) and specimens artificial accelerated aging (Immediate, test with no
aging; Mediate, test performed after 2 months of water storage at 37°C). After
root canal preparation, endodontic filling was not performed. Fibreglass posts
were cemented with self-adhesive resin cement (RelyX U100, 3M-ESPE) and
roots were cross-sectioned to obtain two slices of each third. Samples were
submitted to micropush-out test and bond strength values (MPa) were analyzed
by ANOVA in a split-plot arrangement and Tukey’s test (α = 0.05). Failure
modes were evaluated under a confocal microscope. Part 2. 60 bovine incisors
were divided into 6 experimental groups (n=10) resulting from the interaction
between 2 study factors: endodontic sealer (Sx- Sealapex; S26- Sealer 26; AHAH
Plus) and specimens artificial accelerated aging (Immediate, test with no
aging; Mediate, test performed after 2 months of water storage at 37°C). Two
control groups were employed (without root canal filling), represented by groups
RCPNiTiNaOCl immediate and RCPNiTiNaOCl mediate of part 1 of the present
study. In the six experimental groups, root canals were prepared 1mm from the
apex with K3 Nickel-Titanium instruments associated with 1% sodium
hypochlorite irrigation and 17% EDTA. They were then filled with gutta-percha
and the specific sealer of each group, using the lateral compaction technique.
Fibreglass posts were cemented with self-adhesive resin cement (RelyX U100,
3M-ESPE) and roots were cross-sectioned to obtain two slices of each third.
Abstract xx
Samples were submitted to micropush-out test and bond strength values (MPa)
were submitted to ANOVA in a split-plot arrangement and Tukey’s test (α =
0,05). Comparisons with control groups were made using Dunnet test (α = 0.05).
Failure modes were evaluated under a confocal microscope. Results: Part 1. In
specimens submitted to water artificial aging, RCPNiTi presented higher bond
strength values than RCPSS in apical third irrigated with NaOCl or CHX.
Irrigation with NaOCl resulted in higher bond strength than O3. Artificial aging
resulted in significant bond strength increase, except for middle and apical thirds
of RCPSSO3 and apical of RCPNiTiO3. Bond strength significantly reduced in
apical third. The prevalence of adhesive cement-dentine failure was verified in
all groups. Part 2. Endodontic sealers showed no significant differences among
them, however they presented significantly lower bond strength values than
control groups (without filling), except in cervical third of groups tested
immediately. Artificial aging did not interfere on bond strength to intraradicular
dentine. There was a significant decrease on bond strength from cervical to
apical third. The prevalence of adhesive cement-dentine failure was verified in
all groups. Conclusions: Part 1. Root canal preparation with NiTi instruments
associated with NaOCl irrigation and EDTA increased the bond strength of
fiberglass posts cemented with self-adhesive resin cement to intraradicular
dentine. Part 2. Endodontic sealers interfered negatively on bonding of
fibreglass posts cemented with self-adhesive resin cement to intraradicular
dentine. / Objetivo: Analisar in vitro a influência das técnicas de instrumentação do canal radicular, dos irrigantes e cimentos endodônticos e do envelhecimento artificial acelerado na resistência de união do pino de fibra de vidro à dentina intrarradicular em dentes bovinos. Metodologia: Parte 1. Cento e vinte incisivos bovinos foram divididos em doze grupos experimentais (n=10) resultantes da interação entre três fatores em estudo: técnica de instrumentação do canal radicular (PAI – preparo do canal radicular com instrumentos de aço inoxidável - K-File; PNiTi – preparo do canal radicular com instrumentos de Níquel-Titânio - K3); irrigante endodôntico (NaOCl- hipoclorito de sódio 1%; CHX- clorexidina 2%; O3- água ozonificada 1,2%) (em todas as amostras o EDTA 17% foi utilizado para a remoção de smear layer) e envelhecimento artificial acelerado dos espécimes (Imediato, teste sem envelhecimento; Mediato, teste após 2 meses de envelhecimento em água a 37°C). Após o preparo dos canais radiculares não foi realizada a obturação endodôntica. Pinos de fibra de vidro foram cimentados com cimento resinoso auto-adesivo (RelyX U100, 3M-ESPE) e as raízes foram seccionadas para obtenção de duas fatias de cada terço. As amostras foram submetidas ao teste
de micropush-out e os dados de resistência de união (MPa) foram analisados por ANOVA com parcela subdividida e teste de Tukey (α = 0,05). Os padrões de falha foram avaliados por meio de microscopia confocal. Parte 2. Sessenta incisivos bovinos foram divididos em seis grupos experimentais (n=10)
resultantes da interação entre dois fatores em estudo: cimento endodôntico (SX- Sealapex; S26- Sealer 26; AH- AH Plus) e envelhecimento artificial acelerado dos espécimes (Imediato, teste sem envelhecimento; Mediato, teste após 2 meses de envelhecimento em água a 37°C). Foram empregados dois grupos controles (sem obturação do canal radicular) representados pelos grupos PNiTiNaOCl imediato e PNiTiNaOCl mediato da parte 1 do presente estudo. Nos seis grupos experimentais os canais radiculares foram preparados 1mm aquém do ápice com instrumentos de Níquel-Titânio - K3 associado a
Resumo xviii irrigação com NaOCl 1% e EDTA 17%. Em seguida, foram obturados com gutapercha
e o cimento endodôntico específico de cada grupo, usando a técnica de condensação lateral. Pinos de fibra de vidro foram cimentados com cimento resinoso auto-adesivo (RelyX U100, 3M-ESPE) e as raízes foram seccionadas para obtenção de duas fatias de cada terço. As amostras foram submetidas ao teste de micropush-out e os dados de resistência de união (MPa) foram analisados por ANOVA com parcela subdividida e teste de Tukey (α = 0,05). Comparações com os grupos controles foram feitas pelo teste de Dunnet (α =0,05). Os padrões de falha foram avaliados por meio de microscopia confocal.
Resultados: Parte 1. Nos espécimes submetidos ao envelhecimento artificial em água, PNiTi apresentou maiores valores de resistência de união que PAI no terço apical irrigado com NaOCL ou CHX. A irrigação com NaOCL resultou em maior resistência de união comparada a O3. O envelhecimento artificial resultou
em aumento significante da resistência de união, exceto para os terços médio e apical de PAIO3 e apical de PNiTiO3. A resistência de união reduziu significativamente no terço apical. A prevalência de falha adesiva cimentodentina foi verificada em todos os grupos. Parte 2. Os cimentos endodônticos não mostraram diferenças significantes entre si, entretanto apresentaram valores de resistência de união significativamente menores que os grupos controles (sem obturação), exceto no terço cervical dos grupos testados
imediatamente. O envelhecimento artificial não interferiu na resistência de união à dentina intrarradicular. Houve uma diminuição significante na resistência de união do terço cervical para o apical. A prevalência de falha adesiva cimentodentina foi verificada em todos os grupos. Conclusões: Parte 1. O preparo do
canal radicular com instrumentos de NiTi associado a irrigação com NaOCl e uso do EDTA aumentou a resistência de união de pinos de fibra de vidro cimentados com cimento auto-adesivo à dentina intrarradicular. Parte 2. Os cimentos endodônticos interferiram negativamente na união de pinos de fibra de
vidro cimentados com cimento auto-adesivo à dentina intrarradicular.
|
347 |
Avaliação in vitro da morfologia e da resistência de união de adesivos à dentina humana hígida ou submetida à ciclagem erosiva e irradiada com os lasers de Er:YAG e Er,Cr:YSGG / In vitro evaluation of the morphology and the bond strength of adhesives to sound and artificially eroded human dentin irradiated with Er:YAG and Er,Cr:YSGG laserThaysa Monteiro Ramos 04 July 2012 (has links)
A erosão dental provoca alterações histológicas complexas na dentina e, apesar do aumento da ocorrência desta patologia na última década, a literatura apresenta poucos estudos sobre a adesão na dentina erodida. Com o aprimoramento da tecnologia e o conhecimento de que os lasers de érbio apresentam grande afinidade pela água e hidroxiapatita, sua utilização tem sido considerada um método alternativo para tratamento da superfície dentinária antes dos procedimentos adesivos. Assim, o objetivo deste trabalho in vitro foi avaliar o efeito de diferentes tratamentos de superfície (ponta diamantada, laser de Er:YAG 2,94 m, 60 mJ, 2 Hz, 0,2 W, 19,3 J/cm2 - e laser de Er,Cr:YSGG 2,78 m, 50 mJ, 30 Hz, 1,5 W, 4,5 J/cm2), prévios ao tratamento restaurador, tanto na dentina humana hígida quanto na dentina artificialmente erodida. Metade das amostras foi submetida à ciclagem erosiva, a qual foi realizada durante 5 dias por meio da imersão em solução de ácido cítrico 0,05 M (pH 2,3, 10 minutos, 6x/dia) e solução supersaturada (pH 7,0, 60 minutos entre os ataques ácidos). Na fase experimental 1, 32 fragmentos de dentina foram divididos aleatoriamente em 8 grupos (n = 4) e com o auxílio da Microscopia Eletrônica de Varredura (MEV), realizou-se a análise da morfologia da superfície da dentina hígida e da submetida à ciclagem erosiva, após os diferentes tratamentos de superfície. Na fase experimental 2, 192 terceiros molares humanos foram divididos aleatoriamente em 2 grupos (dentina hígida e dentina submetida à ciclagem erosiva) e 8 subgrupos (n = 12) para avaliação da resistência de união entre as superfícies tratadas e 2 sistemas adesivos (01 autocondicionante e 01 com condicionamento ácido prévio), por meio do ensaio de microtração e da análise do padrão de fratura. Para o ensaio de microtração, blocos de resina composta microhíbrida foram confeccionados na superfície de dentina e, após armazenados em água destilada-deionizada por 24h (37oC), palitos foram obtidos para serem tracionados na máquina de ensaio universal (0,5mm/min). A análise do padrão de fratura realizada em microscópio ótico (40x) e as avaliações das eletromicrografias foram feitas de forma descritiva. Os valores obtidos de resistência de união(MPa) foram submetidos aos testes de ANOVA (dois fatores) e de comparações múltiplas de Tukey (p<0,05). A análise morfológica de superfície mostrou alterações significativas da dentina hígida e da dentina artificialmente erodida, submetidas aos diferentes tratamentos de superfície. Quanto à resistência de união, na dentina hígida, o grupo controle, tanto do sistema autocondicionante (54,69 ± 7,80 MPa) quanto do condicionamento ácido total (47,36 ± 9,35 MPa), apresentou valores significativamente maiores que os outros grupos, sendo, porém, diferentes entre si. Na dentina erodida, a maior resistência de união foi alcançada com o grupo tratado com o laser de Er,Cr:YSGG associado ao adesivo autocondicionante (28,26 ± 9,22 MPa), o qual foi significativamente diferente de todos demais grupos. Com base nos parâmetros de irradiação utilizados neste estudo, pode-se concluir que em dentina hígida, os tratamentos de superfície com os lasers de Er:YAG e Er,Cr:YSGG apresentaram resultados de adesão inferiores, mas satisfatórios, em relação ao grupo controle. Já em substrato dentinário erodido, a irradiação com laser de Er,Cr:YSGG, associada ao uso de sistema adesivo autocondicionante, promoveu efeito positivo para a adesão à resina composta. / Dental erosion can cause complex histological changes in dentin and, despite the increase in its incidence during the last decade, limited information is available regarding adhesion to eroded dentin. With improvements in technology and due to the fact that the erbium lasers have high affinity to water and hydroxyapatite, the use of laser can consist on an alternative for the treatment of dentin surface before adhesive procedures. The aim of this in vitro study was to evaluate the effect of different surface treatments (diamond bur, Er:YAG laser 2.94 m, 60 mJ, 2 Hz, 0.2 W, 19.3 J/cm2 - and Er,Cr:YSGG laser 2.78 m, 50 mJ, 30 Hz, 1.5 W, 4.5 J/cm2) prior to restorative treatment, in sound and artificially eroded human dentin. Half of the samples was submitted to the erosive cycling, which was performed by immersion in 0.05 M citric acid (pH 2.3, 10 min, 6x/day) and in supersaturated solution (pH 7.0, 1h, between acid attacks), during 5 days. In phase 1, 32 dentin fragments were randomly divided into 8 groups (n = 4). The analysis of surface morphology of both sound and eroded dentin was performed by Scanning Electron Microscopy (SEM), after the different surface treatments. In phase 2, 192 human third molars were randomly divided into 2 groups (sound and eroded dentin) and 8 subgroups (n=12) to evaluate the bond strength between the treated surfaces and composite resin, with two adhesive systems (self-etching and total-etching) by means of the microtensile bond strength (TBS) test and fracture pattern analysis. For the microtensile bond strength test, blocks of composite resin were bonded to the samples and, after 24 h-storage in distilled/deionized water (37°C), stick-shapped samples were obtained and submitted to TBS test in a universal testing machine (0.5 mm/min). The fracture pattern was performed with an optical microscopy (40x) and the evaluations of the electromicrographs were made under a descriptive mode. The bond strength values (MPa) were analyzed by two-way ANOVA and Tukey tests ( = 0.05). In sound dentin, for the control group, both self-etching (54.69 ± 7.8 MPa) and total-etching adhesive system (47.36 ± 9.3 MPa) showed significantly higher values than all other groups (p<0.05), even though they differ from each other. However, in eroded dentin groups, the self-etching on the samples treated with the Er,Cr:YSGG laser presented the highest mean (28.3 ± 9.2 MPa), which was statistically significant higher than all the other treatments (p<0.05). Based on the irradiation parameters considered for this study, it can be concluded that in healthy dentin, the surface treatment with Er:YAG and Er,Cr:YSGG irradiation showed bonding values lower than the control group, but they presented satisfactory results. However, in eroded dentin, the use of Er,Cr:YSGG laser, associated with the self-etching adhesive system, promoted positive effect on adhesion to composite resin.
|
348 |
Influência de variáveis metodológicas no valor da resistência de união material adesivo/substrato dentinário e, no padrão de fratura: ensaio de \"micro\" cisalhamento / Methodological variables influence on bonding of adhesive material/dentin substrate and fracture pattern micro shear testAndréa Mello de Andrade 10 December 2010 (has links)
A influência de variáveis metodológicas no valor da resistência de união e no padrão de fratura, por ensaio de microcisalhamento, foi verificada em dentina planificada de molares humanos e estudada em quatro diferentes experimentos, nos quais dois sistemas adesivos foram utilizados (Adper Single Bond 2 e XP Bond) e uma resina composta (Filtek Z250). Foram eles: Experimento 1- momento de fotoativação do adesivo: antes ou após o posicionamento das cânulas sobre o substrato dentinário; Experimento 2- tempo de armazenagem: 10min, 24 horas, 48 horas e 7 dias em água destilada a 37oC; Experimento 3- área de secção transversal dos corpos de prova: 0,44mm2, 0,82mm2, 1,98mm2 e 4,44mm2; Experimento 4- momento de fotoativação da resina / remoção da cânula para o ensaio. Os dados obtidos de resistência de união, em MPa, foram tratados por métodos de ANOVA. Os corpos de prova resultantes de todos os experimentos foram observados em microscopia eletrônica de varredura e analisados de forma qualitativa quanto ao modo de fratura. Houve diferença significativa no Experimento 1, sendo que os valores médios de resistência de união foram mais altos quando os adesivos foram fotoativados antes de posicionar as cânulas. Não houve diferença estatisticamente significante para as variáveis tempo de armazenagem e sistema adesivo (Experimento 2), e nem para as variáveis área de secção transversal e sistema adesivo estudadas (Experimento 3). Para o Experimento 4, houve diferença estatisticamente significante para a condição experimental resina fotoativada e remoção da cânula quando previamente realizada à adesão ao substrato e entre os adesivos. Em todos os experimentos o modo de fratura foi predominantemente adesivo/misto. Concluiu-se que algumas variáveis do método são fundamentais para sua padronização, pois com base nos resultados deste estudo elas influenciam os valores médios da resistência de união. / The effect of methodological variables on the microshear bond strength and fracture pattern was assessed in flat human molars dentin in four different experiments using two adhesive systems (Adper Single Bond 2 and XP Bond) and a composite resin (Filtek Z250). The experiments were: 1. Adhesive light activation moment prior or after mold positioning on dentin; 2. Storage period 10 min, 24h, 48h or 7 days in distilled water at 37oC; 3. Mold transversal section area 0.44mm2, 0.82mm2, 1.98mm2 and 4.44mm2; 4. Resin light activation moment with or without mold removal prior to testing. Mean data values (MPa) were subjected to ANOVAs methods. All fractured specimens were qualitatively analyzed in SEM to verify the fracture mode. Regarding Experiment 1 a significative difference was shown for the main factor Adhesive Light Activation Moment; higher bond strength values were achieved with adhesive system ligth activated before mold positioning. No significant differences were found for storage period or section area analyzed on Experiments 2 and 3, respectively. The main factor Resin Light Activation Moment presented differences when the resin composite was previously light activated and mold was removed prior to bonding the resin with the adhesive systems. In all experiments, mode of failure was predominantly adhesive/mixed. The conclusion is that some variables of the method are essential for its standardization, given that they influence the bond strength values.
|
349 |
"Avaliação de cerâmicas odontológicas quanto à resistência de união com a dentina, por ensaio de tração, microdurezas Knoop e Vickers, rugosidade superficial e microscopia de força atômica" / Evaluation of dental ceramics regarding tensile bond strength to dentin, Knoop and Vickers microhardness, surface roughness and atomic force microscopyRicardo Ruiz Martuci 01 June 2006 (has links)
Foram ensaiadas quatro cerâmicas VMK 95, Omega 900, IPS d. Sign e Cergogold. Os ensaios realizados foram: 1) resistência de união, por ensaio de tração, à dentina humana, de cones (6 x 3 x 5mm) de cerâmica, unidos por meio de cimentos fosfato de zinco, resinosos Rely X e Panávia F (n=10); 2) rugosidade pelos parâmetros Ra, Rt, Ry, Rz e Rp, de superfícies tratadas com ácido fluorídrico a 10% e polidas (n=10); 3) durezas Knoop e Vickers (n=4); 4) análise por microscopia de força atômica de superfícies polidas apenas (n=5). Os dados foram analisados pela análise de variância e testes de Tukey foram feitos quando necessário. A resistência de união com o fosfato de zinco e o parâmetro de rugosidade Ra foram analisados em separado, por apresentarem variâncias bem menores que as correspondentes aos demais agentes cimentantes e parâmetros. Os resultados mostraram que a resistência de união com o fosfato de zinco foi muito baixa (1,61 a 2,91MPa), nas condições dos ensaios. Com cimentos resinosos a resistência média variou de 16,61 a 18,47MPa. O cimento Rely X apresentou menor resistência em média, mas isto também depende da cerâmica.As rugosidades das superfícies tratadas com ácido fluorídrico a 10% foram bem maiores do que nas polidas. Nessas o parâmetro Ra variou de 2,15 a 4,26µm e os demais parâmetros de 10,99 a 21,93µm. Nas superfícies polidas o Ra variou de 0,53 a 0,84µm. Os demais parâmetros apresentaram médias de 2,01 a 5,23µm. A dureza Knoop variou de 418,9 a 493,8 kgf/mm2 e a Vickers de 492,5 a 572,2 kgf/mm2. Esta última apresentou valores maiores. A microscopia de força atômica permitiu visualizar irregularidades de superfícies. As principais conclusões foram: o cimento de fosfato de zinco, na condição do ensaio (por tração) apresentou resistência de união muito baixa; com os cimentos resinosos a resistência de união foi bem alta; as rugosidades foram muito altas após o tratamento superficial com ácido fluorídrico a 10%, mas, as polidas apresentaram valores bem baixos; as durezas Vickers fornecem valores maiores que a Knoop. / Four ceramics (VMK 95, Omega 900, IPS d.Sign and Cergogold) were tested regarding: 1) tensile bond strength to human dentin of ceramic cones (6 x 3 x 5mm), cemented with zinc phosphate, and resin cements, Rely X and Panávia F (n=10); 2) roughness by means of parameters Ra, Rt, Ry, Rz and Rp, of HF (10%) surface treated and polished surfaces (n=10); 3) Knoop and Vickers hardness (n=4); 4) atomic force microscopy; only of polished surfaces (n=5). Data were analyzed by ANOVA and when necessary were used Tukeys tests. Tensile bond strength with zinc phosphate cement and Ra roughness parameter were analyzed separately because of their low variances when compared with those of resin cements and the other roughness parameter. Results showed that tensile bond strength of zinc phosphate was very low (1.61 to 2.91MPa) in this test condition (tensile test). Resin cements presented tensile bond strength at range 16.61 to 18.47MPa. Cement Rely X presented lower strength, but it depends also of ceramic. HF (10%) treated surfaces presented much higher roughness than polished ones. In HF (10%) treated surfaces parameter Ra ranged from 2.15 to 4.26µm and the other parameter ranged from 10.99 to 21.93µm. Roughness of polished surfaces Ra ranged from 0.53 to 0.84µm. Range of the other parameter was from 2.01 to 5.23µm. Knoop hardness ranged from 418.9 to 493.8 kgf/mm2 and Vickers from 492.5 to 572.2 kgf/mm2. This type presented higher values. Atomic force microscopy permited good vision of surface irregularities. Main conclusions were: zinc phosphate cement at test conditions (tensile) presented low bond strength; resin cements presented high tensile bond strength; surface treatment with HF (10%) led to high roughness but in polished one it was low; Vickers hardness presented higher values than Knoop one.
|
350 |
Avaliação dos ensaios de microtração, push-out e pull-out: resistência de união entre pino de fibra e dentina radicular, análise de elementos finitos e microscopia confocal / Evaluation of microtensile, push-out and pull-out bond strength tests in the adhesion of fiber posts to intraradicular dentin. Finite element analysis and confocal microscopyCarina Strano Castellan 28 June 2007 (has links)
O objetivo deste estudo foi comparar os ensaios de microtração (MI), ?push-out? (PS), ?push-out? modificado (PSM) e ?pull-out? (PL) na habilidade de mensurar a resistência de união (RU) entre pino de fibra e dentina radicular. Para tanto, além dos resultados de cada ensaio mecânico foram analisados fatores como: sensibilidade quanto às diferentes regiões radiculares, quantidade de falhas prematuras (FP), coeficiente de variação (CV), padrão de fratura (PF) pela microscopia confocal de varredura e distribuição das tensões pela análise de elementos finitos (AEF). Foram utilizados 40 dentes anteriores superiores endodonticamente tratados, divididos em quatro grupos de acordo com o tipo de ensaio realizado. Para os ensaios de PS e MI foi feita a cimentação do pino e posteriormente os cortes para a obtenção dos corpos-de-prova (cps). Para os outros ensaios (PSM e PL), a cimentação antecedeu aos cortes tanto das fatias de dentina como dos pinos. O sistema adesivo Scotbond Multi Uso Plus e o cimento Variolink II foram usados para a cimentação do pino de fibra de vidro FRC Postec Plus em todos os casos. Os cps do ensaio de PS foram obtidos pelos cortes seriados da raiz em fatias de 1±0,1mm, para os cps do ensaio de MI estas fatias sofreram ainda a confecção de entalhes laterais diametralmente opostos, que proporcionando um formato final de ampulheta. Para os testes de PL e PSM foram feitos cortes de fatias de dentina de 1±0,1mm e o pino foi dividido em três partes iguais para, então, cada fatia de uma região ser cimentada com o pino correspondente. Os cps do ensaio de PSM tinham 1mm de pino sobressalente para cima e para baixo da fatia de dentina, enquanto que os cps do PL o pino sobressalente estava apenas para cima da dentina. Todos os cps foram submetidos aos testes de RU, à velocidade de 0,5mm/min em máquina de ensaios universais. O PF foi avaliado em um aumento de cem vezes e foi feita uma distribuição de freqüência. Já a AEF obteve modelos tridimensionais de todos os ensaios, e estes foram analisados quanto à tensão de Von Mises. Para os resultados dos testes mecânicos foram feitas análises de variância de cada ensaio variando o fator região, com ou sem as FP, e análise comparando todos os ensaios. O teste Tukey foi feito quando necessário e as FP foram submetidas ao teste estatístico de Fisher. A inclusão ou não destas falhas mostra alteração dos resultados no ensaio de MI, uma vez que possui um maior número delas neste ensaio. O ensaio de PL mostrou as maiores médias de RU, seguido pelo ensaio de PSM, e ambos também tiveram o PF com maior quantidade de fraturas adesivas. O ensaio de PS conseguiu apontar diferença estatística entre as três regiões, mas mostrou a maior freqüência de falhas coesivas, e maior CV. O menor CV foi encontrado para o PSM que também mostrou uma adequada distribuição das tensões. A MI apresentou concentração de tensões nas bordas dos entalhes. Concluiu-se que o tipo de ensaio influencia diretamente nos resultados obtidos. / The aim of this study was to compare microtensile (MI), \"push-out\" (PS), modified \"push-out\" (PSM) and \"pull-out\" (PL) tests in the ability to accurately measure the bond strength of fiber posts luted inside root canals, at different root dentin levels, cervical, middle and apical. The evaluated parameters were: amount of premature failure (PF), coefficient of variation (CV), failure patterns (FP) and the stress distribution by finite elements analysis (FEA). Forty human intact single-rooted and endodontically treated teeth were divided into four groups according to the type test used. For PS and MI specimens, first the post was luted and then the cuts were done, for PSM and PL, first was done the cuts and then fiber post?s pices were luted. Scotbond Multi Use Plus adhesive system and Variolink II cement had been used for luting FRC Postec Plus glass fiber post, in all cases. PS samples were disc shaped of 1±0,1mm. Bond strength between post and dentin was measured in the root slice and the force applied on the center of the specimen. For the Mi test hourglass-shaped samples were obtained by trimming the proximal surfaces of each slice using a diamond bur until it touched the post. For PL and PSM tests cuts of 1±0,1mm of dentine slices were made and the fiber was divided into three parts, and then each slice were luted with a fiber post?s piece. Specimens for PSM had 1mm of post up and down the dentin slice and for PL all of the post was up the dentine slice. All specimens were submitted to a bond strength test at 0.5 mm/minute crosshead speed in a universal testing machine. For FP, each sample was examined under confocal microscopy at 100 times and a frequency distribution was made. For the AEF, three-dimensional models of each tests had been made and analyzed by Von Mises stress. Bond strength data were analyzed by ANOVA and when necessary was used Tukey?s test. For PF data the Fisher test was made. The inclusion of PF, only shows variation on MI, since these test showed the greater number of them. PL provided higher values of bond strength for root dentin and fiber post, followed by PSM. Both of them had also FP with greater amount of adhesive failures. The PS test was able to point statistically differences between root regions, but it showed the highest frequency of cohesive failure, and greater CV. Minor CV was found for the PSM that also showed adequate stress distribution. The MI showed concentration of tensions in the edges of the trimming area. One concluded that the type of test influences directly in the results obtained.
|
Page generated in 0.0723 seconds