• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 67
  • 67
  • 30
  • 26
  • 21
  • 18
  • 14
  • 14
  • 13
  • 12
  • 12
  • 12
  • 12
  • 12
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Efeitos da radiação ionizante nas proteínas presentes em ossos humanos desmineralizados, liofilizados ou congelados / Effects of ionizing radiation on proteins in demineralized, lyophilized or frozen human bone

ANTEBI, URI 12 November 2015 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-11-12T10:30:34Z No. of bitstreams: 0 / Made available in DSpace on 2015-11-12T10:30:34Z (GMT). No. of bitstreams: 0 / Os tecidos ósseos alógenos são utilizados nas cirurgias de reconstrução ortopédicas e odontológicas. O número crescente de transplantes de ossos na última década beneficia diversos pacientes. Os profissionais dos Bancos de Tecidos utilizam protocolos que reduzem os riscos de transmissão de doenças infectocontagiosas, entretanto, não eliminam esta possibilidade. Portanto, é importante que tecidos sejam esterilizados por um método eficaz, sendo usualmente aplicada a radiação ionizante. Porém, a radiação ionizante pode acarretar alterações estruturais e biológicas nos ossos em relação à dose. O objetivo deste trabalho foi estudar os efeitos da aplicação da radiação gama e de feixe de elétrons, nas doses de 15 kGy, 25 kGy e 50 kGy nos tecidos ósseos desmineralizados preservados liofilizados ou congelados e avaliar as possíveis alterações no colágeno, na concentração de proteínas totais, BMP-2 e BMP-7. Para tanto foram utilizadas as técnicas de espectroscopia Raman, Bradford e ELISA. Foram utilizadas 5 diáfises de femur humano e parte das amostras foram desmineralizadas. As proteínas ósseas foram extraídas e quantificadas. Com os resultados da espectroscopia Raman, observamos que a eficiência da desmineralização foi de 85 a 90% porém com alterações na estrutura do colágeno. Alterações também foram observadas nos ossos congelados e irradiados nas doses de 25 kGy e 50 kGy. Nos resultados da quantificação de proteínas totais e específicas, ocorreram diminuições gradativas das concentrações médias das proteínas em relação à dose de radiação nos grupos estudados. Nas doses de radiação usualmente aplicadas aos tecidos ósseos, 15 kGy ou 25 kGy, as reduções nas concentrações das BMP-2 e BMP-7, foram menores que 20%. As reduções na dose de 50 kGy foram entre 27% a 53%, sendo influenciadas pelo tipo de radiação e pelo tipo de preservação dos ossos. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
62

Analyse de la tenue mécanique des implants, des composants prothétiques et de l'interaction avec les tissus osseux en implantologie dentaire / Analysis of the mechanical strength of implants, prosthetic components and interaction with bone tissue in dental implantology

De La Rosa Castolo, Guillermo 07 December 2018 (has links)
Ce travail de recherche vise à développer des méthodologies d’évaluation mécanique des implants dentaires, de leurs composants prothétiques et de l’interaction avec les tissus osseux de la mâchoire. D’après l’Organisation Mondiale de la Santé (OMS), 15 à 20% de la population âgée de 35 à 44 ans est atteint de problèmes d’édentation partielle et près de 30% de la population âgée de 65 à 74 d’édentation totale. Cela représente donc approximativement 7 millions de personnes en France ayant subi des pertes de dents durant leur vie. Les traitements proposés par l’implantologie dentaire sont devenus des solutions efficaces pour les problèmes d’édentation avec des taux de réussite cliniques supérieurs à 90%. Cependant, des complications cliniques existent, caractérisées par des inflammations ou des pertes partielles des tissus environnants. Les dentistes étant responsables du choix du traitement thérapeutique pour leurs patients, la prise d’une décision appropriée est capitale et exige une compréhension des risques et des bénéfices. C’est dans ce contexte qu’une première méthodologie d’évaluation a été développée pour améliorer le design des implants dentaires de type endosseux, dans les conditions de la norme de certification ISO 14801. La méthodologie est basée sur des approches numériques par Analyse d’Eléments Finis. Ensuite, des approches théoriques et des données cliniques ont été utilisées pour évaluer le comportement mécanique des tissus osseux de la mâchoire face aux différentes configurations par implants dentaires et leurs composants prothétiques. / The research purpose in this study is to develop of mechanical evaluation methods to dental implants, their prosthetic components and the interactions with bone tissues in mandible zone. According to the World Health Organization (WHO), 15 to 20% of population from 35 to 44 years old is reached of partial edentulism problems and about 30% of population from 65 to 74 years old is reached of complete edentulism problems. This represents approximately 7 million people in France who have lost teeth during their lifetime. Treatments proposed by dental implantology have become effective solutions for edentulous patients with clinical success rates greater than 90%. However, clinical complications exist, characterized by inflammation or partial losses of the surrounding tissues. Dentists are responsible for the treatment choice for their patients; an appropriate decision is crucial and requires an understanding of the benefits and risks. In this context, a first methodology was developed for evaluated the endosseous dental implants under the conditions of the ISO 14801 certification standard. This methodology is based with an approach numerical by Finite Element Analysis (FEA). Furthermore, theoretical approaches and clinical data were used to evaluate the mechanical resistance of the bone tissues in the jaw with different dental implant configurations and their prosthetic components.
63

Desenvolvimento de um sistema dosimetrico para situacoes de emergencia envolvendo pessoas do publico em geral

COSTA, ZELIA M. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:48:45Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:58Z (GMT). No. of bitstreams: 1 06637.pdf: 6435317 bytes, checksum: dd71fbfbf870392236b27f85714133b5 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
64

Avaliação in vitro dos efeitos da radiação ionizante em tecido ósseo bovino por espectroscopia ATR-FTIR e análise dinâmico-mecânica / In vitro evaluation of ionizing radiation effects in bone tissue by FTIR spectroscopy and dynamic mechanical analysis

VELOSO, MARCELO N. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:07Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:44Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
65

Desenvolvimento de um sistema dosimetrico para situacoes de emergencia envolvendo pessoas do publico em geral

COSTA, ZELIA M. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:48:45Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:58Z (GMT). No. of bitstreams: 1 06637.pdf: 6435317 bytes, checksum: dd71fbfbf870392236b27f85714133b5 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
66

Avaliação in vitro dos efeitos da radiação ionizante em tecido ósseo bovino por espectroscopia ATR-FTIR e análise dinâmico-mecânica / In vitro evaluation of ionizing radiation effects in bone tissue by FTIR spectroscopy and dynamic mechanical analysis

VELOSO, MARCELO N. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:07Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:44Z (GMT). No. of bitstreams: 0 / A radiação ionizante de fontes de radiação gama ou geradores de raios-x é frequentemente utilizada na ciência médica, como em exames de radiodiagnóstico, radioterapia e esterilização de aloenxertos. A radiação ionizante é capaz de quebrar cadeias polipeptidicas e provocar a libertação de radicais livres, pela radiólise de moléculas de água. A radiação ionizante interage também com o material orgânico a nível molecular, podendo alterar as suas propriedades mecânicas. No caso específico do tecido ósseo, estudos reportam que a radiação ionizante induz alterações nas moléculas de colágeno e reduzem a densidade de ligações cruzadas intermoleculares. O objetivo deste estudo foi verificar as alterações promovidas por diferentes doses de radiação ionizante no tecido ósseo utilizando a técnica de Espectroscopia Transformada de Fourier com Reflexão Total Atenuada (ATR-FTIR), e também a análise dinâmico-mecânica. Amostras de osso bovino foram irradiadas usando irradiador de Cobalto-60, com cinco doses diferentes: 0,01 kGy, 0,1 kGy, 1 kGy, 15 kGy e 75 kGy. Para estudar os efeitos da radiação ionizante sobre a estrutura química do osso foram avaliadas a relação material orgânico por material inorgânico, a relação de sub-bandas de amida I e o índice de cristalinidade. As alterações mecânicas foram determinadas por meio do módulo de elasticidade e do valor do amortecimento. Para verificar se as mudanças químicas e as características mecânicas de osso possuem alguma relação, realizou-se um estudo sobre a correlação entre as análises feitas com os dados espectroscópicos e as análises mecânicas. Foi possível avaliar os efeitos de diferentes doses de radiação ionizante no tecido ósseo. Com a análise por espectroscopia ATR-FTIR, foi possível observar as modificações dos componentes orgânicos e na organização cristais de hidroxiapatita. Também foram observadas alterações no módulo elástico e na tangente de delta (dissipação de energia mecânica). Foram encontradas altas correlações com significância estatística entre a relação das bandas (amida III + colágeno)/v1,v3, PO43- com a tangente de delta, e entre a relação 1/FHMW e o módulo elástico. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
67

Avaliação histomorfométrica, imunoistoquímica e microtomográfica da ação da terapia laser de baixa potência no processo de reabsorção radicular durante movimentação ortodôntica induzida em ratos / Histomorphometric, immunohistochemistry and microtomography evaluation of the effect of low level laser therapy in root reabsorption process during orthodontic movement induced in rats

SUZUKI, SELLY S. 11 November 2016 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2016-11-11T17:46:50Z No. of bitstreams: 0 / Made available in DSpace on 2016-11-11T17:46:50Z (GMT). No. of bitstreams: 0 / A movimentação dentária induzida é um processo biológico complexo mediado por estímulos mecânicos, levando a um subsequente processo de remodelação óssea, podendo haver reabsorção indesejada da raiz dentária provocada pelo excesso de força. Uma vez que a movimentação ortodôntica se baseia em um processo inflamatório localizado, o propósito deste estudo foi avaliar os efeitos do laser de baixa potência no processo de remodelação óssea e reabsorção radicular, buscando correlacionar as mudanças metabólicas observadas a nível celular ocorridas nos dias iniciais da movimentação dentária às alterações teciduais observadas microscopicamente e à arquitetura e morfologia do trabeculado e cortical ósseo. Primeiros molares de sessenta e oito ratos machos Wistar foram submetidos à movimentação induzida, divididos em 3 grupos: controle negativo (nenhuma movimentação), não irradiado (movimentação sem irradiação) e laser (movimentação e irradiação com laser de baixa potência de comprimento de onda de 810 nm, potência de 100 mW, área de 0,02cm2 e energia de 1,5 J/ponto) e eutanasiados nos dias 3, 6, 9, 14 e 21. Mensurações da movimentação dentária e análises histomorfométricas foram realizadas em todos os dias estudados. Análise imunoistoquímica dos marcadores RANKL, OPG e TRAP e avaliações por microscopia eletrônica de varredura (MEV) foram feitas nos dias 3, 6 e 9 e o ensaio Western Blotting para proteínas RANKL e SOFAT e imagens de microtomografia computadorizada (MicroCT) nos dias 14 e 21. Os resultados deste estudo mostraram que a movimentação dentária foi significantemente maior no grupo Laser (aumento em média de 40%) em todos os dias avaliados. O lado de compressão mostrou maior expressão de RANKL e osteoclastos TRAP-positivos nos dias 3, 6 e 9 (p<0,05), promovendo significativa redução na área de osso alveolar presente no lado de compressão nos dias 6, 9 e 14 (p<0,05), e alterações microestruturais, como menor fração de volume ósseo/volume total, menor densidade óssea mineral aos 14 dias. A irradiação com laser também aumentou a expressão de RANKL e a citocina SOFAT no dia 14. No lado de tensão, houve maior expressão de OPG especialmente aos 9 dias (p<0,001) e significativo aumento na área de osso alveolar presente nos dias 14 (p<0,01) e 21 (p<0,05) histomorfometricamente e maior densidade óssea mineral e espessura das trabéculas aos 21 dias (p<0,01). Com relação às áreas de hialinização presentes, os resultados mostraram áreas significantemente reduzidas nos dias 3, 6 e 9 nos grupos irradiados, o que explica o menor número de odontoclastos na superfície radicular nestes dias e a redução significante das áreas de reabsorção radicular observadas nas lâminas histológicas nos dias 9, 14 e 21 e nas imagens de MEV nos dias 3 e 9. Os grupos irradiados também mostraram menor volume das lacunas de reabsorção radicular medidas no MicroCT nos dias 14 e 21, especialmente nos lados de compressão. O estudo concluiu que o laser de baixa potência influenciou a remodelação óssea, aumentou a atividade dos osteoclastos no lado da compressão, e estimulou a formação óssea no de tensão, acelerando significativamente o movimento dentário e potencialmente reduzindo as áreas de necrose no ligamento periodontal e, consequentemente, a reabsorção radicular. / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.0482 seconds