• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 23
  • 10
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 38
  • 13
  • 11
  • 7
  • 7
  • 7
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Desarrollo de un sistema de control avanzado de la presión del vapor en una caldera de tubos de fuego

Rodríguez Vásquez, José Renato 09 May 2011 (has links)
Esta tesis presenta el siguiente objetivo: Desarrollar un sistema de control avanzado de la variación de la presión del vapor en el cuerpo de una caldera de tubos de fuego, que posibilite un funcionamiento efectivo y fiable del proceso de combustión, así como una disminución del actual consumo de combustible y de los gases contaminantes del medio ambiente. / Tesis
12

Selección de bomba centrifuga para caldero

Ortíz Cerna, Juan Carlos January 2014 (has links)
Publicación a texto completo no autorizada por el autor / El documento digital no refiere asesor / Manifiesta como aprender y reconocer las principales variables que intervienen en la selección de un equipo de bombeo, así como conocer las herramientas (programas) que ayudan a la selección de los equipos, también detalla las generalidades de la selección de electrobombas y como son utilizadas en los calderos. La mala elección del equipo puede derivar en cavitaciones, un exceso o insuficiente caudal a la caldera ocasionara un mal funcionamiento de esta. Al igual que si no calculamos la presión necesaria. / Trabajo de suficiencia profesional
13

Caldera collapse and the generation of waves

Gray, James Paul Peter, 1976- January 2001 (has links)
Abstract not available
14

Aproximación al estudio del riesgo del bleve y sus efectos en los generadores marinos de vapor y los tanques de carga de los buques LNG-LPG. Aplicación comparativa de las normas que lo regulan y previenen

Melo Rodríguez, Germán de 04 July 1994 (has links)
BELEVE son las iniciales de la siguiente expresión inglesa "Boiling Liquid Expanding Vapor Explosion" que traducido librementes ignifica "Explosión de los Vapores que se expanden al hervir un líquido".La ELEVE es comúnmente definida como la ruptura en varios pedazos de un recipiente, con proyección a grandes distancias, superiores a las que las desplazarían la simple energía de un estallido, que se da en determinadas circunstancias, siendo necesario, pero no suficiente, que el líquido contenido en el recipiente, posea una temperatura superior a la que le correspondería tener si estuviera a la presión atmosférica normal. Por tanto, la temperatura de ebullición debe ser bastante menor que la temperatura a la que se encuentre la masa líquida en el recipiente, es decir, lo que se llama o denomina líquido sobrecalentado.El fenómeno ELEVE es una manifestación exclusiva de los líquidos sobrecalentados, no debiéndose confundir con las explosiones que se producen en los recipientes que solamente contienen gas, pues las energías desarrolladas por la explosión de este último, no son en absoluto comparables a las elevadas del fenómeno ELEVE.En el caso de que el fenómeno ELEVE se manifieste en un recipiente que contiene líquido que es químicamente reactivo o combustible, agrava el problema de la ELEVE propiamente dicho, ya que anteriormente se ha indicado que un ELEVE se puede producir en una caldera de vapor de agua.Las condiciones necesarias que se han de dar simultáneamente.
15

Epithermal vein and carbonate replacement mineralization related to caldera development, Cunningham Gulch, Silverton, Colorado

Hardwick, James Fredrick, January 1984 (has links) (PDF)
Thesis (M.A.)--University of Texas at Austin, 1984. / Vita. Includes bibliographical references (leaves 119-124).
16

Geology, geochemistry and petrology of the Pizarro and Pinto domes and the Tepeyahualco flows to the Los Humeros caldera complex, Puebla, Mexico

García-Banda, Rosalba January 1984 (has links)
No description available.
17

Cálculo térmico en el diseño de una caldera pirotubular de 5BHP

Quispe Cóndor, Félix Martín January 2018 (has links)
Publicación a texto completo no autorizada por el autor / El documento digital no refiere asesor / Se desarrolla los cálculos de transferencia de energía que ocurren en una caldera pirotubular de 5BHP, en base a los parámetros de presión de operación de 55 PSI a la que debe funcionar la caldera usando las ecuaciones básicas de mecánica de fluidos y transferencia de calor, suponiendo que la caldera alcanza un estado estable durante su operación, además se supone que la caldera tiene una eficiencia térmica de un 70%. / Trabajo de suficiencia profesional
18

A model of the hydrothermal system at Casa Diablo in Long Valley, California, based on resistivity profiles and soil mercury analyses

Arfstrom, John David 22 July 1993 (has links)
A description and model of the near-surface hydrothermal system at Casa Diablo, with its implications for the larger-scale hydrothermal system of Long Valley, California, is presented. The data include resistivity profiles with penetrations to three different depth ranges, and analyses of inorganic mercury concentrations in 144 soil samples taken over a 1.3 by 1.7 km area. Analyses of the data together with the mapping of active surface hydrothermal features (fumaroles, mudpots, etc.), has revealed that the relationship between the hydrothermal system, surface hydrothermal activity, and mercury anomalies is strongly controlled by faults and topography. There are, however, more subtle factors responsible for the location of many active and anomalous zones such as fractures, zones of high permeability, and interactions between hydrothermal and cooler groundwater. In addition, the near-surface location of the upwelling from the deep hydrothermal reservoir, which supplies the geothermal power plants at Casa Diablo and the numerous hot pools in the caldera with hydrothermal water, has been detected. The data indicate that after upwelling the hydrothermal water flows eastward at shallow depth for at least 2 km and probably continues another 10 km to the east, all the way to Lake Crowley.
19

Análisis mecánico del efecto sísmico en el piping interior de una caldera en una central térmica

Cerda Escobar, Daniel Martín January 2017 (has links)
Ingeniero Civil Mecánico / Un estudio reciente de modelación sísmica de una caldera ha detectado posibles colisiones entre sus elementos interiores. En particular, los haces de tubos que operan en la etapa de sobrecalentamiento y recalentamiento, chocan contra las paredes laterales de la caldera, durante un sismo. Dada la envergadura de la estructura y considerando también las condiciones de operación, no se tiene certeza de cuáles serían los efectos que puede originar el impacto de los tubos interiores. Es por este motivo, que el objetivo principal de este trabajo consiste en plantear una estrategia de solución al eventual problema de choque. La metodología utilizada considera un modelo computacional de tubos cuyo diseño se asemeja en mayor medida a aquel indicado en los planos mecánicos de la caldera. Además, su respuesta dinámica obedece a parámetros sísmicos cuyas solicitaciones son más exigentes, de acuerdo a lo establecido por la norma de diseño sísmica chilena. Para determinar el máximo desplazamiento del haz de tubos durante un sismo, estos son excitados mediante una aceleración sinusoidal, cuya amplitud y frecuencia representa el movimiento del techo de la caldera. Sumada a esta respuesta armónica de los tubos, que superpone los máximos modales, se añade el ángulo de rotación que sufren al nivel de su anclaje con el techo de la caldera. Los resultados indican que es altamente probable que ocurra una colisión entre los tubos de agua y las paredes laterales de la caldera, ya que el desplazamiento máximo que sufre la parte inferior del haz de tubos supera la holgura disponible. Para evaluar la magnitud del impacto, se utiliza la teoría desarrollada para el contacto entre superficies sólidas (esféricas). Donde a partir de la energía almacenada como deformación elástica en el haz de tubos, se determina el trabajo de compresión que realiza la fuerza de impacto, de acuerdo al número de tubos en contacto. Los resultados advierten que el daño no es despreciable. Se estima que la fuerza de impacto entre el tubo de agua y el tubo de pared podría alcanzar los 155 [kN], desarrollando un comportamiento en el rango plástico. Sin bien es cierto que difícilmente ocurra una ruptura catastrófica, el daño local puede ser un sitio de inicio de corrosión, causando problemas de mediano a largo plazo. Una posible solución a este problema consiste en evitar el contacto entre tubos, al interponer una placa en la trayectoria de éstos, mitigando la deformación plástica local.
20

Geology, geochemistry and petrology of the Pizarro and Pinto domes and the Tepeyahualco flows to the Los Humeros caldera complex, Puebla, Mexico

García-Banda, Rosalba January 1984 (has links)
No description available.

Page generated in 0.0611 seconds