21

Caracterização e quantificação de antioxidantes em microemulsão a/o de biodiesel por eletroforese capilar e voltametria

Casagrande, Marcella January 2012 (has links)
Métodos voltamétricos e por cromatografia capilar eletrocinética em microemulsão (MEEKC) com detecção UV foram empregados neste estudo para desenvolver metodologia de análise direta dos antioxidantes BHA, TBHQ, BHT e PG em biodiesel, sem extração ou pré-concentração, empregando a técnica de adição de padrão. Água, SDS e n-pentanol constituem a microemulsão do tipo água em óleo (ME a/o) na qual foi dissolvida a amostra de biodiesel. Nesse meio, a partição dos analitos ocorre entre a fase contínua da ME e as gotículas de água. Tanto medidas por voltametria potenciodinâmica como de pulso diferencial indicaram uma relação linear entre o teor de TBHQ no meio e a corrente de oxidação, obtendo-se, a partir das curvas analíticas, concentrações em biodiesel de mesma ordem de grandeza, o que evidencia a viabilidade dessa determinação.Nos ensaios por MEEKC, não foi possível separar os antioxidantes BHA, TBHQ e BHT, provavelmente por terem mobilidades semelhantes às dos ésteres do biodiesel, nas condições dos experimentos.A adição de trietilamina (TEA) à ME a/o, visando obter o ânion correspondente ao PG, permitiu sua separação e identificação com um tempo de retenção de 17 minutos e tempo de migração relativo 0,23. A reação entre o PG e a TEA foi confirmada por espectrometria de absorção no UV-Vis. Ainda, as baixas condutividades das MEs a/o contendo biodiesel evitaram o efeito antistacking, favorecendo seu uso na análise direta de antioxidantes por voltametria e MEEKC. / Voltammetry and microemulsion electrokinetic chromatography (MEEKC) with UV detection were employed in this study aiming the direct analysis of the antioxidants BHA, TBHQ, BHT and PG in biodiesel, without pre-concentration or extraction, using the standard addition method. The biodiesel sample was dissolved in a water-in-oil microemulsion (w/o ME) containing water, n-pentanol and SDS. In this medium, the partitioning of the analytes takes place between the w/o ME continuous phase and the disperded water droplets. Determination of the TBHQ content in biodiesel, either through potentiodynamic voltammetry or differential pulse voltammetry indicated a linear relationship between the oxidation current and the concentration of the antioxidant. The results obtained from the analytical curves showed concentrations of the analyte in biodiesel of the same order of magnitude, evidencing the viability of the procedure. Separation of the antioxidants BHA, BHT and TBHQ were not feasible through MEEKC, probably because their mobilities are similar to those of the biodiesel esters under the experimental conditions employed. Addition of triethylamine (TEA) to the w/o ME, in order to obtain the PG corresponding anion, allowed its separation and identification with a retention time of 17 minutes and a relative migration time of 0.23. The reaction between PG and TEA in the w/o ME was confirmed by UV-Vis absorption spectroscopy. Still, the low conductivities of the w/o MEs containing biodiesel avoided antistacking effect, thus favoring the direct analysis of antioxidants by voltammetry and MEEKC.
22

Transferência de calor e controle de temperatura em tubos capilares utilizados em eletroforese capilar

Danieli, Rodrigo January 2005 (has links)
Este trabalho tem por objetivo estudar a transferência de calor em tubos capilares cilíndricos utilizados na técnica de separação de moléculas denominada Eletroforese Capilar. Esta técnica é usada, por exemplo, na análise de biomoléculas e no sequenciamento de DNA, onde o controle da temperatura está diretamente ligado ao desempenho destes métodos e à qualidade dos resultados. Para empregar esta técnica, tensões elétricas da ordem de 20 kV são aplicadas entre as extremidades dos tubos capilares, que possuem normalmente 50 cm de comprimento, 350 µm de diâmetro externo e 50 µm de diâmetro interno, preenchidos por uma solução aquosa. Tais tensões geram uma corrente elétrica na solução, provocando aquecimento distribuído por Efeito Joule. Os tubos capilares são construídos em quartzo amorfo e protegidos por uma camada de material polimérico (poliimida). Para implementar o controle da temperatura, os tubos capilares são colocados em contato com um fluido de resfriamento. Num primeiro momento, os estudos são realizados por simulação numérica, empregando o Método dos Volumes Finitos em rotinas escritas em FORTRAN. São simulados casos onde os tubos são recobertos por camadas cilíndricas de materiais com uma condutividade térmica relativamente boa, com o objetivo de aumentar a superfície de troca de calor com o fluido de resfriamento. Como resultado, obtêm-se curvas da temperatura no centro dos tubos capilares em função do coeficiente de transferência de calor por convecção. Um caso de interesse é quando os tubos capilares são posicionados excentricamente ao recobrimento cilíndrico Num segundo momento, é utilizado o software de simulação numérica ANSYS CFX®, onde é simulado o resfriamento dos mesmos tubos capilares expostos a um escoamento transversal de ar a 15°C. Neste caso, também são aplicados os recobrimentos cilíndricos e, além disso, opta-se por simular o resfriamento de um arranjo de vários tubos (sistema multicapilar) dispostos entre placas de vidro, no formato de um sanduíche. Como resultados mais importantes salientam-se: a) o aumento do raio do recobrimento resulta no aumento da transferência de calor, fazendo com que a temperatura no núcleo do capilar fique estacionada em valores baixos que não comprometem as separações/análises; b) chegou-se a um valor de raio crítico da ordem de 10 mm para a condição de operação mais típicas na área da Eletroforese Capilar; c) as montagens com o tubo capilar concêntrico e excêntrico ao recobrimento não apresentam diferenças significativas no perfil de temperatura da solução tampão; e finalmente d) observa-se que o uso de duas placas de material dielétrico com os capilares posicionados em forma de sanduíche entre elas permite uma eficiente dissipação do calor gerado na solução tampão.
23

Análise de resíduos de sulfonamidas em alimentos por eletroforese capilar e espectrometria de massas

Hoff, Rodrigo Barcellos January 2008 (has links)
O objetivo deste trabalho é o desenvolvimento e validação de um método analítico preciso, rápido, simples e de baixo custo para o monitoramento de resíduos de sulfonamidas em alimentos, que fosse capaz de ser aplicado a um grande número de amostras de distintas matrizes e que fornecesse dados quantitativos e confirmatórios da possível presença desta classe de fármacos em alimentos. O trabalho foi realizado em quatro fases distintas. A fase I consistiu na tabulação e estudo de todas as apresentações de sulfonamidas disponíveis no mercado de produtos de uso veterinário no Brasil. Da análise farmacológica e farmacotécnica deste universo, delineou-se uma abordagem para prioritização para sulfas que podem, potencialmente, permanecerem como resíduos em alimentos destinados ao consumo humano. Na fase II, desenvolveu-se um protocolo de extração, purificação e concentração de sulfonamidas a partir de matrizes de origem animal - carne, pescado e leite. Distintas abordagens analíticas foram testadas e comparadas quanto à rapidez, recuperação de analito, repetibilidade e custo. A fase III tratou do desenvolvimento de um método de análise por eletroforese capilar com detecção por fluorescência induzida a laser para análise qualitativa e quantitativa de sulfonamidas. Na fase IV, desenvolveu-se um método confirmatório para a presença de sulfas em alimentos utilizando a espectrometria de massas acoplada à cromatografia líquida. O método confirmatório foi validado de acordo com a Diretiva da Comunidade Européia EC/657/2002, que estabelece os critérios mínimos de desempenho para métodos de análise de resíduos de drogas veterinárias em alimentos. Amostras de alimentos de origem animal contendo níveis de sulfonamidas acima de 10 ng g-1 puderam ser analisadas, quantificadas e confirmadas através da aplicação do método desenvolvido. / The aim of this work is the development of a precise, fast, simple and low cost analytical method for sulfonamide residues in food, which were able to be applied to a large number of samples of different matrices and to provide quantitative data and confirm the possible presence of this class of drugs in food. In the initial approach of the work, all veterinary medicines containing sulfonamides available in the Brazilian market were evaluated to propose a new approach for risk assessment to prioritisation of sulfonamides that have the potential to remain as residues in food and in the environment. After, protocols for extraction, purification and concentration of sulfonamides from matrices of animal origin were developed. Different analytical approaches were tested and compared on the speed, recovery of analyte, repeatability and cost. In the next stage, a method based on analysis by capillary electrophoresis with detection by laser induced fluorescence was developed to allow qualitative screening of sulfonamide residues. Finally, a confirmatory method was developed using liquid chromatography coupled to mass spectrometry. The method was validated according to the European Community Decision EC/657/2002 which established the minimum performance criteria for methods of analysis of veterinary drugs residues in food. Food sample containing levels of sulfonamides up to 10 ng g-1 could be analyzed, quantified and confirmed using the method developed.
24

Caracterização e quantificação de antioxidantes em microemulsão a/o de biodiesel por eletroforese capilar e voltametria

Casagrande, Marcella January 2012 (has links)
Métodos voltamétricos e por cromatografia capilar eletrocinética em microemulsão (MEEKC) com detecção UV foram empregados neste estudo para desenvolver metodologia de análise direta dos antioxidantes BHA, TBHQ, BHT e PG em biodiesel, sem extração ou pré-concentração, empregando a técnica de adição de padrão. Água, SDS e n-pentanol constituem a microemulsão do tipo água em óleo (ME a/o) na qual foi dissolvida a amostra de biodiesel. Nesse meio, a partição dos analitos ocorre entre a fase contínua da ME e as gotículas de água. Tanto medidas por voltametria potenciodinâmica como de pulso diferencial indicaram uma relação linear entre o teor de TBHQ no meio e a corrente de oxidação, obtendo-se, a partir das curvas analíticas, concentrações em biodiesel de mesma ordem de grandeza, o que evidencia a viabilidade dessa determinação.Nos ensaios por MEEKC, não foi possível separar os antioxidantes BHA, TBHQ e BHT, provavelmente por terem mobilidades semelhantes às dos ésteres do biodiesel, nas condições dos experimentos.A adição de trietilamina (TEA) à ME a/o, visando obter o ânion correspondente ao PG, permitiu sua separação e identificação com um tempo de retenção de 17 minutos e tempo de migração relativo 0,23. A reação entre o PG e a TEA foi confirmada por espectrometria de absorção no UV-Vis. Ainda, as baixas condutividades das MEs a/o contendo biodiesel evitaram o efeito antistacking, favorecendo seu uso na análise direta de antioxidantes por voltametria e MEEKC. / Voltammetry and microemulsion electrokinetic chromatography (MEEKC) with UV detection were employed in this study aiming the direct analysis of the antioxidants BHA, TBHQ, BHT and PG in biodiesel, without pre-concentration or extraction, using the standard addition method. The biodiesel sample was dissolved in a water-in-oil microemulsion (w/o ME) containing water, n-pentanol and SDS. In this medium, the partitioning of the analytes takes place between the w/o ME continuous phase and the disperded water droplets. Determination of the TBHQ content in biodiesel, either through potentiodynamic voltammetry or differential pulse voltammetry indicated a linear relationship between the oxidation current and the concentration of the antioxidant. The results obtained from the analytical curves showed concentrations of the analyte in biodiesel of the same order of magnitude, evidencing the viability of the procedure. Separation of the antioxidants BHA, BHT and TBHQ were not feasible through MEEKC, probably because their mobilities are similar to those of the biodiesel esters under the experimental conditions employed. Addition of triethylamine (TEA) to the w/o ME, in order to obtain the PG corresponding anion, allowed its separation and identification with a retention time of 17 minutes and a relative migration time of 0.23. The reaction between PG and TEA in the w/o ME was confirmed by UV-Vis absorption spectroscopy. Still, the low conductivities of the w/o MEs containing biodiesel avoided antistacking effect, thus favoring the direct analysis of antioxidants by voltammetry and MEEKC.
25

Desenvolvimento e otimização de métodos rápidos para análise simultânea de glicerina (livre e total), Na+, K+, Ca2+ e Mg2+ em biodiesel por eletroforese capilar

Spudeit, Daniel Alfonso January 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas. Programa de Pós-Graduação em Química / Made available in DSpace on 2012-10-26T09:52:39Z (GMT). No. of bitstreams: 0
26

Metodologia analítica para a determinação de ácidos graxos em óleo vegetal

Böckel, Wolmir José January 2009 (has links)
A separação cromatográfica de misturas de compostos hidrofóbicos, com cadeias carbônicas longas, apresenta dificuldades como, por exemplo, o entupimento da coluna de separação. Assim, técnicas alternativas de separação e quantificação destes compostos têm sido investigadas. O aumento da cadeia carbônica diminui drasticamente a solubilidade dos ácidos graxos em meios solventes, porém esta limitação é contornada preparando a amostra de óleo na forma de microemulsão (ME), permitindo o emprego de técnicas eletroanalíticas em razão da elevada condutividade característica desses sistemas. Este trabalho teve por objetivo o desenvolvimento de metodologia analítica para a quantificação de ácidos graxos livres presentes em óleo de soja diretamente na amostra, sem a necessidade de extração prévia, empregando cromatografia eletrocinética capilar em microemulsões (MEEKC) e eletroforese capilar em solventes orgânicos, ambas com detecção oscilométrica. Foi investigado o comportamento eletroquímico de MEs constituídas de dodecil sulfato de sódio, SDS, pentanol e água, cujo diagrama de fases apresenta uma ampla região de miscibilidade, bem como de microemulsões contendo óleo de soja. Nessa região, para uma faixa de composições correspondendo a diferentes tipos de microemulsões, foram estudadas propriedades como o comportamento das fases e a influência da natureza do cosurfactante e quantificados parâmetros físico-químicos ainda desconhecidos nesses meios, por exemplo, sua condutividade, raio, carga elétrica e coeficiente de difusão das gotículas. Na caracterização das MEs foram empregadas as técnicas de espalhamento de luz dinâmico (DLS), espalhamento de raios-x a baixo ângulo (SAXS), voltametria potenciodinâmica, espectroscopia de impedância eletroquímica (EIS) e condutometria. A identificação dos ácidos oléico e palmítico foi realizada em corridas individuais, usando como eletrólito de corrida uma mistura de NaOH, DMF e butanol, com um tempo de análise em torno de 50 minutos, aproximadamente. Já para a ME utilizando como eletrólito de corrida octano, 1-butanol e SDS em tetraborato de sódio aquoso, não houve a separação dos ácidos mencionados. O eletrólito de corrida que melhor atendeu aos requisitos necessários para a determinação da concentração do ácido oléico livre em óleo de soja foi uma mistura contendo 4 x 10-2 mol L-1 de KOH em metanol:propanol na proporção de 1:6, e 10 % em etilenoglicol, com um tempo de análise relativamente pequeno, comparativamente ao sistema hidroorgânico. / The chromatographic separation of hydrophobic compounds from mixtures presents some difficulties such as the occlusion of the column. Therefore, alternative techniques to separate and quantify these compounds have been investigated. Although the solubility of fatty acids in most solvents falls significantly with increasing carbon chain length this difficulty can be surmounted by preparing the oil sample as a microemulsion (ME) which allows carrying on electroanalytical measurements due to the higher conductivity these systems present as compared to oils and fats. The aim of this study is to develop analytical methodology in order to quantify free fatty acids in soybean oil, without previous extraction, by microemulsion electrokinetic capillary chromatography (MEEKC) and capillary electrophoresis, both with oscillometric detection. The electrochemical behavior of microemulsions (MEs) prepared with n-pentanol, SDS and water, the phase diagram of which presents a large miscibility region, as well as MEs containing soybean oil, have been investigated. In this region, for composition ranges corresponding to different types of MEs, the behaviour of the phases and the role of the cosurfactant nature have been investigated. Moreover, some physical-chemical parameters, up to now unknown in the studied media, such as conductivity, radii of the particles and their diffusion coefficient were quantified. Techniques such as dynamic light scattering (DLS) and small angle x-ray scattering (SAXS), linear voltammetry, electrochemical impedance spectroscopy and conductometry were employed in the characterization of the MEs. A carrier electrolyte prepared with a mixture of NaOH, DMF and butanol evidenced the presence of either oleic and palmitic acids in individual runs with a time analysis around 50 minutes. For a soybean oil ME using octane, 1-butanol and SDS in aqueous sodium tetraborate as carrier electrolyte there was no separation of the mentioned fatty acids. Finally, the carrier electrolyte prepared with 4 x 10-2 mol L-1 KOH in metanol:propanol 1:6 and, w/w, and 10 % ethileneglycol allowed the determination of the free oleic acid content in a soybean oil sample with a quite short time of analysis as compared to the previous system.
27

Análise de resíduos de sulfonamidas em alimentos por eletroforese capilar e espectrometria de massas

Hoff, Rodrigo Barcellos January 2008 (has links)
O objetivo deste trabalho é o desenvolvimento e validação de um método analítico preciso, rápido, simples e de baixo custo para o monitoramento de resíduos de sulfonamidas em alimentos, que fosse capaz de ser aplicado a um grande número de amostras de distintas matrizes e que fornecesse dados quantitativos e confirmatórios da possível presença desta classe de fármacos em alimentos. O trabalho foi realizado em quatro fases distintas. A fase I consistiu na tabulação e estudo de todas as apresentações de sulfonamidas disponíveis no mercado de produtos de uso veterinário no Brasil. Da análise farmacológica e farmacotécnica deste universo, delineou-se uma abordagem para prioritização para sulfas que podem, potencialmente, permanecerem como resíduos em alimentos destinados ao consumo humano. Na fase II, desenvolveu-se um protocolo de extração, purificação e concentração de sulfonamidas a partir de matrizes de origem animal - carne, pescado e leite. Distintas abordagens analíticas foram testadas e comparadas quanto à rapidez, recuperação de analito, repetibilidade e custo. A fase III tratou do desenvolvimento de um método de análise por eletroforese capilar com detecção por fluorescência induzida a laser para análise qualitativa e quantitativa de sulfonamidas. Na fase IV, desenvolveu-se um método confirmatório para a presença de sulfas em alimentos utilizando a espectrometria de massas acoplada à cromatografia líquida. O método confirmatório foi validado de acordo com a Diretiva da Comunidade Européia EC/657/2002, que estabelece os critérios mínimos de desempenho para métodos de análise de resíduos de drogas veterinárias em alimentos. Amostras de alimentos de origem animal contendo níveis de sulfonamidas acima de 10 ng g-1 puderam ser analisadas, quantificadas e confirmadas através da aplicação do método desenvolvido. / The aim of this work is the development of a precise, fast, simple and low cost analytical method for sulfonamide residues in food, which were able to be applied to a large number of samples of different matrices and to provide quantitative data and confirm the possible presence of this class of drugs in food. In the initial approach of the work, all veterinary medicines containing sulfonamides available in the Brazilian market were evaluated to propose a new approach for risk assessment to prioritisation of sulfonamides that have the potential to remain as residues in food and in the environment. After, protocols for extraction, purification and concentration of sulfonamides from matrices of animal origin were developed. Different analytical approaches were tested and compared on the speed, recovery of analyte, repeatability and cost. In the next stage, a method based on analysis by capillary electrophoresis with detection by laser induced fluorescence was developed to allow qualitative screening of sulfonamide residues. Finally, a confirmatory method was developed using liquid chromatography coupled to mass spectrometry. The method was validated according to the European Community Decision EC/657/2002 which established the minimum performance criteria for methods of analysis of veterinary drugs residues in food. Food sample containing levels of sulfonamides up to 10 ng g-1 could be analyzed, quantified and confirmed using the method developed.
28

Transferência de calor e controle de temperatura em tubos capilares utilizados em eletroforese capilar

Danieli, Rodrigo January 2005 (has links)
Este trabalho tem por objetivo estudar a transferência de calor em tubos capilares cilíndricos utilizados na técnica de separação de moléculas denominada Eletroforese Capilar. Esta técnica é usada, por exemplo, na análise de biomoléculas e no sequenciamento de DNA, onde o controle da temperatura está diretamente ligado ao desempenho destes métodos e à qualidade dos resultados. Para empregar esta técnica, tensões elétricas da ordem de 20 kV são aplicadas entre as extremidades dos tubos capilares, que possuem normalmente 50 cm de comprimento, 350 µm de diâmetro externo e 50 µm de diâmetro interno, preenchidos por uma solução aquosa. Tais tensões geram uma corrente elétrica na solução, provocando aquecimento distribuído por Efeito Joule. Os tubos capilares são construídos em quartzo amorfo e protegidos por uma camada de material polimérico (poliimida). Para implementar o controle da temperatura, os tubos capilares são colocados em contato com um fluido de resfriamento. Num primeiro momento, os estudos são realizados por simulação numérica, empregando o Método dos Volumes Finitos em rotinas escritas em FORTRAN. São simulados casos onde os tubos são recobertos por camadas cilíndricas de materiais com uma condutividade térmica relativamente boa, com o objetivo de aumentar a superfície de troca de calor com o fluido de resfriamento. Como resultado, obtêm-se curvas da temperatura no centro dos tubos capilares em função do coeficiente de transferência de calor por convecção. Um caso de interesse é quando os tubos capilares são posicionados excentricamente ao recobrimento cilíndrico Num segundo momento, é utilizado o software de simulação numérica ANSYS CFX®, onde é simulado o resfriamento dos mesmos tubos capilares expostos a um escoamento transversal de ar a 15°C. Neste caso, também são aplicados os recobrimentos cilíndricos e, além disso, opta-se por simular o resfriamento de um arranjo de vários tubos (sistema multicapilar) dispostos entre placas de vidro, no formato de um sanduíche. Como resultados mais importantes salientam-se: a) o aumento do raio do recobrimento resulta no aumento da transferência de calor, fazendo com que a temperatura no núcleo do capilar fique estacionada em valores baixos que não comprometem as separações/análises; b) chegou-se a um valor de raio crítico da ordem de 10 mm para a condição de operação mais típicas na área da Eletroforese Capilar; c) as montagens com o tubo capilar concêntrico e excêntrico ao recobrimento não apresentam diferenças significativas no perfil de temperatura da solução tampão; e finalmente d) observa-se que o uso de duas placas de material dielétrico com os capilares posicionados em forma de sanduíche entre elas permite uma eficiente dissipação do calor gerado na solução tampão.
29

Desenvolvimento de método para determinação de composição de atmosfera modificada pela presença de inibidores de corrosão

Silva, Leticia Caetano da [UNESP] 23 June 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-06-23Bitstream added on 2014-06-13T19:17:21Z : No. of bitstreams: 1 silva_lc_me_araiq.pdf: 1267707 bytes, checksum: f59f2d5392cb2f2ac09bc76bc7a49a3f (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Inibidores voláteis de corrosão (IVC) são amplamente utilizados para conferir proteção temporária aos metais ferrosos. Estes inibidores são substâncias que possuem a propriedade de volatilizar a temperatura ambiente, formando uma atmosfera de alta concentração que posteriormente irá se condensar na superfície do metal deixando-o menos suscetível a corrosão. No entanto, estes produtos são comercializados sem que haja padronização e avaliação de qualidade. Atualmente longos ensaios eletroquímicos são utilizados ou somente a quantidade de IVC presente nos suportes é analisada. Pouco estudo tem sido realizado a cerca da quantidade de IVC presente na atmosfera formada. Aminas como monoetanolamina (MEA), monociclohexilamina (MCHA) e diciclohexilamina (DCHA) apresentam propriedades desejáveis de IVC, sendo comumente empregadas. Neste trabalho é desenvolvido um método analítico para avaliar atmosferas modificadas por inibidores voláteis de corrosão. Para coleta e amostragem da atmosfera de interesse otimizouse um método utilizando micro gotas suspensas. Como técnica de separação e determinação utilizou-se a eletroforese capilar (EC) com detecção indireta a 214 nm. Além de eficiente, EC faz uso de micro volumes tornando-a conveniente para o presente estudo. Alternativamente, otimizou-se um método espectrofotométrico a partir da derivação das aminas com o reagente cromóforo p-cloranil, esta técnica foi escolhida visto sua simplicidade e baixo custo. Através dos métodos desenvolvidos foi possível avaliar adequadamente a composição de atmosferas contendo MEA, MCHA e DCHA. Testes colorimétricos em filtros de papel também foram realizados e se mostrou uma alternativa interessante para maiores estudos posteriores. As atmosferas provenientes de amostras plásticas comerciais apresentaram DCHA como principal amina inibidora, apresentando quantidades... / Volatile Corrosion Inhibitors (VCIs) are widely used to provide ferrous metals temporary protection. These substances have the vaporing property at room temperature, making a high concentration atmospheric, which subsequently will condense on the metallic surface, making it less susceptible to corrosion. Therefore, these products are commercialized without proper standardization and quality evaluation. Currently lengthy electrochemical tests are applied or only the amount of VCI on support is analyzed. Little study has been done about the amount of VCI in the atmosphere formed. Amines such as monoethanolamine (MEA), monocyclohexylamine (MCHA) and dicyclohexylamine (DCHA) have desirable properties of VCI and this why are commonly used as one. An analytical method to evaluate modified atmospheres by volatile corrosion inhibitors was developed. Hangdrops were used as collector and sampler of atmosphere, several papers have been published about its versatility and efficiency. Such as separation and determination technique the capillary electrophoresis (CE) with indirect detection to 214 nm was used. In addition other advantage is the use the small volumes by CE. Alternatively, spectrophotometric method was enhanced, amines derivatization by chromophore p-chloranil reagent was used, this technique has been chosen due its simplicity and low cost. By these developed methods is possible to determine rightly the atmosphere composition with MEA, MCHA and DCHA contained. Colorimetric tests were made on filter paper and the results were promising. Results show commercial plastic samples atmosphere have DCHA as the main inhibitor and it was less quantity on support than atmosphere, although DCHA quantities on support after 8 months was kept. Degradation of MEA under salt form was evaluated and results shown beginner solution modification after few days.
30

Transferência de calor e controle de temperatura em tubos capilares utilizados em eletroforese capilar

Danieli, Rodrigo January 2005 (has links)
Este trabalho tem por objetivo estudar a transferência de calor em tubos capilares cilíndricos utilizados na técnica de separação de moléculas denominada Eletroforese Capilar. Esta técnica é usada, por exemplo, na análise de biomoléculas e no sequenciamento de DNA, onde o controle da temperatura está diretamente ligado ao desempenho destes métodos e à qualidade dos resultados. Para empregar esta técnica, tensões elétricas da ordem de 20 kV são aplicadas entre as extremidades dos tubos capilares, que possuem normalmente 50 cm de comprimento, 350 µm de diâmetro externo e 50 µm de diâmetro interno, preenchidos por uma solução aquosa. Tais tensões geram uma corrente elétrica na solução, provocando aquecimento distribuído por Efeito Joule. Os tubos capilares são construídos em quartzo amorfo e protegidos por uma camada de material polimérico (poliimida). Para implementar o controle da temperatura, os tubos capilares são colocados em contato com um fluido de resfriamento. Num primeiro momento, os estudos são realizados por simulação numérica, empregando o Método dos Volumes Finitos em rotinas escritas em FORTRAN. São simulados casos onde os tubos são recobertos por camadas cilíndricas de materiais com uma condutividade térmica relativamente boa, com o objetivo de aumentar a superfície de troca de calor com o fluido de resfriamento. Como resultado, obtêm-se curvas da temperatura no centro dos tubos capilares em função do coeficiente de transferência de calor por convecção. Um caso de interesse é quando os tubos capilares são posicionados excentricamente ao recobrimento cilíndrico Num segundo momento, é utilizado o software de simulação numérica ANSYS CFX®, onde é simulado o resfriamento dos mesmos tubos capilares expostos a um escoamento transversal de ar a 15°C. Neste caso, também são aplicados os recobrimentos cilíndricos e, além disso, opta-se por simular o resfriamento de um arranjo de vários tubos (sistema multicapilar) dispostos entre placas de vidro, no formato de um sanduíche. Como resultados mais importantes salientam-se: a) o aumento do raio do recobrimento resulta no aumento da transferência de calor, fazendo com que a temperatura no núcleo do capilar fique estacionada em valores baixos que não comprometem as separações/análises; b) chegou-se a um valor de raio crítico da ordem de 10 mm para a condição de operação mais típicas na área da Eletroforese Capilar; c) as montagens com o tubo capilar concêntrico e excêntrico ao recobrimento não apresentam diferenças significativas no perfil de temperatura da solução tampão; e finalmente d) observa-se que o uso de duas placas de material dielétrico com os capilares posicionados em forma de sanduíche entre elas permite uma eficiente dissipação do calor gerado na solução tampão.

Page generated in 0.0649 seconds