Spelling suggestions: "subject:"case posthardcore"" "subject:"case posturescore""
1 |
Avaliação comparativa da influência do tratamento superficial e do agente cimentante na retenção de núcleos metálicos fundidos em titânio c.p. / Comparative evaluation of the influence of superficial treatment and luting agent to the tensile strength of titanium cast post and coresMenani, Luiz Ricardo 21 December 2005 (has links)
O uso de núcleos metálicos fundidos é comum na Odontologia Restauradora para promover a substituição de estruturas perdidas em dentes tratados endodonticamente. Estes núcleos podem ser fundidos em ligas nobres ou ligas básicas: as ligas alternativas apresentam vantagens mas são susceptíveis à corrosão. O titânio foi introduzido na Odontologia com o objetivo de compensar as deficiências dos metais básicos, principalmente a corrosão e seus produtos. Então, a proposta deste estudo foi comparar a resistência à tração de núcleos metálicos fundidos confeccionados em liga de ouro tipo III, titânio e titânio tratado superficialmente com solução de Kroll quando fixados com diferentes agentes cimentantes. Quarenta e dois caninos humanos extraídos foram selecionados, a porção coronária foi removida e a raiz remanescente foi tratada endodonticamente. Todos os espécimes foram divididos em seis grupos (n=7). O espaço para pino foi preparado a uma profundidade de 10mm usando-se brocas de Largo. Os núcleos foram fundidos em liga de ouro tipo III e titânio c.p. e fixados com cimento de fosfato de zinco ou cimento resinoso (Panavia F). A resistência à tração foi determinada em uma máquina universal de ensaios a uma velocidade de 0,5mm/min utilizando-se uma célula de carga de 50 Kgf. Os resultados foram analisados estatisticamente por ANOVA, demonstrando que não houve diferença estatisticamente significante entre os grupos. Dentro das limitações deste estudo pode-se concluir que os núcleos metálicos fundidos em titânio c.p. fixados com cimento fosfato de zinco ou cimento resinoso são uma alternativa viável aos núcleos metálicos fundidos em ouro. / The use of cast post and core is common in restorative dentistry to provide long-term tooth structure replacement for endodontically treated teeth. They could be cast in precious or basic alloys: the alternative alloys present advantages but they are susceptible to corrosion and its effects. The titanium was introduced to Dentistry with the objective of compensating the metal basic deficiencies, mainly the corrosion. Then, the purpose of this study was to compare the tensile resistance among gold alloy, titanium, and titanium after a superficial treatment with Krolls solution when fixed with different luting agents. Forty two human extracted canines were selected, the coronal aspect of each tooth was removed and the remaining root received endodontic therapy. All specimen were divided into six groups (n=7). The post space was prepared at a depth of 10mm using a Largos drill. The cast post and core were manufactured using a type III gold alloy and titanium. Cast post and core were fixed with zinc phosphate or resin luting agent (Panavia F). Tensile bond strength of the specimens was measured with a universal testing machine at a crosshead speed of 0,5mm/min and cell-load of 50 Kgf. Data (Kgf) were statistically analyzed by ANOVA. The results demonstrated that there was not a significant difference among the groups. Within the limitations of this study it has been conclude that the titanium fixed with zinc phosphate or resin luting agent is a viable alternative to the gold alloy to fabricate cast post and cores.
|
2 |
Resistência à fratura e padrões de falha de raízes bovinas enfraquecidas restauradas com diferentes tipos de pino / Fracture strength and failure patterns of flared bovine roots resin-reinforced and restored with different postsHumberto Oliveira Pinto 14 December 2007 (has links)
Proposição: Este estudo in vitro comparou a resistência à fratura e os padrões de falha de 5 tipos diferentes de pinos-núcleos cimentados em raízes bovinas. Materiais e métodos: Um total de 50 incisivos bovinos frescos foram utilizados. A coroa, o terço cervical e parte do terço médio radicular foram removidos. Os dentes selecionados foram divididos em cinco grupos (n=10). Quatro grupos foram enfraquecidos utilizando uma seqüência de pontas diamantadas, reforçados com resina composta e restaurados com núcleos metálicos fundidos, pinos de fibra de vidro, pinos de fibra de carbono e pinos de aço inoxidável. Um grupo não sofreu enfraquecimento e foi restaurado com núcleo metálico fundido (grupo controle). Todos os pinos foram cimentados com adesivo Single Bond 2 e cimento resinoso dual RelyX ARC. Cada espécime foi incluído em resina acrílica e recebeu uma coroa total metálica. A máquina de ensaios universais EMIC-2000 foi utilizada para o teste mecânico. Uma carga compressiva com célula de carga de 500Kgf a uma velocidade de 0,5 mm.min-1 foi aplicada em um ângulo de 135º em relação ao longo eixo do dente até ocorrer fratura. Análise de variância e teste de Tukey foram realizados para determinar a significância da resistência à fratura entre os grupos (p<0,05). Resultados: A análise estatística indicou que as raízes íntegras restauradas com núcleos metálicos fundidos (Grupo 1) apresentaram resistência à fratura significativamente maior: 120,02±35,34, seguido pelos grupos de raízes reforçadas com resina composta e restauradas com os seguintes tipos de pino: núcleo metálico fundido (Grupo 2): 77,91±32,86; pino de fibra de vidro (Grupo 3): 69,60±34,44; pino de fibra de carbono (Grupo 4): 48,25±22,84; e pino de aço inoxidável: 42,26±17,52. Os Grupos 2 a 5 apresentaram valores estatisticamente semelhantes entre si. O padrão de fratura variou entre os grupos. O Grupo 1 apresentou um índice de 100% de fratura catastrófica, enquanto o Grupo 4 apresentou apenas 20% de fraturas radiculares. Conclusões: Os resultados mostraram que dentes com estrutura íntegra são mais resistentes que dentes fragilizados e reforçados com resina. Os dentes restaurados com núcleo metálico fundido demonstraram maior resistência à fratura que os dentes restaurados com pinos de fibra de vidro, fibra de carbono e aço inoxidável. Dentes restaurados com pinos de fibra de vidro são altamente resistentes à fratura, enquanto o dentes restaurados com pinos de fibra de carbono possuem uma grande capacidade protetora da estrutura remanescente. Os dentes restaurados com pinos de aço inoxidável apresentaram a menor resistência à fratura dentre os grupos testados, além de, frequentemente, induzir fraturas radiculares / Purpose: This in vitro study compared the fracture strength and the failure patterns of 5 different types of post-and-cores luted in bovine root canals. Materials and methods: A total of 50 recently extracted anterior bovine teeth with similar dimensions were used in this study. Their crowns, coronal thirds and part of the middle thirds of the roots were removed. The selected teeth were divided into five groups (n=10). Four groups were flared using a sequence of diamond burs, reinforced with composite resin and restored with cast metal post-and-core, glass fiber, carbon fiber and stainless steel posts. One group was not flared and restored with cast metal post-and-core (control group). All posts were cemented with Single Bond 2 adhesive system and dual-cured RelyX ARC resin cement. Each specimen was embedded in acrylic resin and received a complete metal crown. The Universal Testing Machine EMIC-2000 was used for the mechanical test. A compressive load with a 500 Kgf load cell, at a crosshead of .5 mm. min-1, was applied at a 135-degrees angle to the long axis of the tooth until fracture occurred. One-way analysis of variance and Tukey test were performed to determine the significance of the fracture strength among the groups (P<.05). Results: The statistical analysis indicated that healthy roots with cast metal post-and-cores (Group 1) had significantly higher fracture strength: 120.02±35.34, followed by the groups of flared roots with resin reinforcement and restored with posts: cast metal post-and-cores (Group 2): 77.91±32.86; glass fiber post (Group 3): 69.60±34.44; carbon fiber post (Group 4): 48.25±22.84; and stainless steel post (Group 5): 42.26±17.52. Groups 2 to 5 were statistically similar to each other. The failure patterns varied between the groups. Group 1 showed an index of 100% of catastrophic fracture, whereas Group 4 had only 20% of root fractures. Conclusions: It can be concluded healthy teeth with complete root structure has higher fracture strength than teeth with resin-reinforced flared roots. Teeth restored with cast metal post-and-cores demonstrated higher fracture strength than teeth restored with glass fiber, carbon fiber and stainless steel posts. Teeth restored with glass fiber posts are highly resistant to fracture, whereas carbon fiber posts protect the remaining dental structure. Teeth restored with stainless steel posts show lower fracture strength and often induce root fractures.
|
3 |
Avaliação comparativa da influência do tratamento superficial e do agente cimentante na retenção de núcleos metálicos fundidos em titânio c.p. / Comparative evaluation of the influence of superficial treatment and luting agent to the tensile strength of titanium cast post and coresLuiz Ricardo Menani 21 December 2005 (has links)
O uso de núcleos metálicos fundidos é comum na Odontologia Restauradora para promover a substituição de estruturas perdidas em dentes tratados endodonticamente. Estes núcleos podem ser fundidos em ligas nobres ou ligas básicas: as ligas alternativas apresentam vantagens mas são susceptíveis à corrosão. O titânio foi introduzido na Odontologia com o objetivo de compensar as deficiências dos metais básicos, principalmente a corrosão e seus produtos. Então, a proposta deste estudo foi comparar a resistência à tração de núcleos metálicos fundidos confeccionados em liga de ouro tipo III, titânio e titânio tratado superficialmente com solução de Kroll quando fixados com diferentes agentes cimentantes. Quarenta e dois caninos humanos extraídos foram selecionados, a porção coronária foi removida e a raiz remanescente foi tratada endodonticamente. Todos os espécimes foram divididos em seis grupos (n=7). O espaço para pino foi preparado a uma profundidade de 10mm usando-se brocas de Largo. Os núcleos foram fundidos em liga de ouro tipo III e titânio c.p. e fixados com cimento de fosfato de zinco ou cimento resinoso (Panavia F). A resistência à tração foi determinada em uma máquina universal de ensaios a uma velocidade de 0,5mm/min utilizando-se uma célula de carga de 50 Kgf. Os resultados foram analisados estatisticamente por ANOVA, demonstrando que não houve diferença estatisticamente significante entre os grupos. Dentro das limitações deste estudo pode-se concluir que os núcleos metálicos fundidos em titânio c.p. fixados com cimento fosfato de zinco ou cimento resinoso são uma alternativa viável aos núcleos metálicos fundidos em ouro. / The use of cast post and core is common in restorative dentistry to provide long-term tooth structure replacement for endodontically treated teeth. They could be cast in precious or basic alloys: the alternative alloys present advantages but they are susceptible to corrosion and its effects. The titanium was introduced to Dentistry with the objective of compensating the metal basic deficiencies, mainly the corrosion. Then, the purpose of this study was to compare the tensile resistance among gold alloy, titanium, and titanium after a superficial treatment with Krolls solution when fixed with different luting agents. Forty two human extracted canines were selected, the coronal aspect of each tooth was removed and the remaining root received endodontic therapy. All specimen were divided into six groups (n=7). The post space was prepared at a depth of 10mm using a Largos drill. The cast post and core were manufactured using a type III gold alloy and titanium. Cast post and core were fixed with zinc phosphate or resin luting agent (Panavia F). Tensile bond strength of the specimens was measured with a universal testing machine at a crosshead speed of 0,5mm/min and cell-load of 50 Kgf. Data (Kgf) were statistically analyzed by ANOVA. The results demonstrated that there was not a significant difference among the groups. Within the limitations of this study it has been conclude that the titanium fixed with zinc phosphate or resin luting agent is a viable alternative to the gold alloy to fabricate cast post and cores.
|
4 |
Resistência à fratura e padrões de falha de raízes bovinas enfraquecidas restauradas com diferentes tipos de pino / Fracture strength and failure patterns of flared bovine roots resin-reinforced and restored with different postsPinto, Humberto Oliveira 14 December 2007 (has links)
Proposição: Este estudo in vitro comparou a resistência à fratura e os padrões de falha de 5 tipos diferentes de pinos-núcleos cimentados em raízes bovinas. Materiais e métodos: Um total de 50 incisivos bovinos frescos foram utilizados. A coroa, o terço cervical e parte do terço médio radicular foram removidos. Os dentes selecionados foram divididos em cinco grupos (n=10). Quatro grupos foram enfraquecidos utilizando uma seqüência de pontas diamantadas, reforçados com resina composta e restaurados com núcleos metálicos fundidos, pinos de fibra de vidro, pinos de fibra de carbono e pinos de aço inoxidável. Um grupo não sofreu enfraquecimento e foi restaurado com núcleo metálico fundido (grupo controle). Todos os pinos foram cimentados com adesivo Single Bond 2 e cimento resinoso dual RelyX ARC. Cada espécime foi incluído em resina acrílica e recebeu uma coroa total metálica. A máquina de ensaios universais EMIC-2000 foi utilizada para o teste mecânico. Uma carga compressiva com célula de carga de 500Kgf a uma velocidade de 0,5 mm.min-1 foi aplicada em um ângulo de 135º em relação ao longo eixo do dente até ocorrer fratura. Análise de variância e teste de Tukey foram realizados para determinar a significância da resistência à fratura entre os grupos (p<0,05). Resultados: A análise estatística indicou que as raízes íntegras restauradas com núcleos metálicos fundidos (Grupo 1) apresentaram resistência à fratura significativamente maior: 120,02±35,34, seguido pelos grupos de raízes reforçadas com resina composta e restauradas com os seguintes tipos de pino: núcleo metálico fundido (Grupo 2): 77,91±32,86; pino de fibra de vidro (Grupo 3): 69,60±34,44; pino de fibra de carbono (Grupo 4): 48,25±22,84; e pino de aço inoxidável: 42,26±17,52. Os Grupos 2 a 5 apresentaram valores estatisticamente semelhantes entre si. O padrão de fratura variou entre os grupos. O Grupo 1 apresentou um índice de 100% de fratura catastrófica, enquanto o Grupo 4 apresentou apenas 20% de fraturas radiculares. Conclusões: Os resultados mostraram que dentes com estrutura íntegra são mais resistentes que dentes fragilizados e reforçados com resina. Os dentes restaurados com núcleo metálico fundido demonstraram maior resistência à fratura que os dentes restaurados com pinos de fibra de vidro, fibra de carbono e aço inoxidável. Dentes restaurados com pinos de fibra de vidro são altamente resistentes à fratura, enquanto o dentes restaurados com pinos de fibra de carbono possuem uma grande capacidade protetora da estrutura remanescente. Os dentes restaurados com pinos de aço inoxidável apresentaram a menor resistência à fratura dentre os grupos testados, além de, frequentemente, induzir fraturas radiculares / Purpose: This in vitro study compared the fracture strength and the failure patterns of 5 different types of post-and-cores luted in bovine root canals. Materials and methods: A total of 50 recently extracted anterior bovine teeth with similar dimensions were used in this study. Their crowns, coronal thirds and part of the middle thirds of the roots were removed. The selected teeth were divided into five groups (n=10). Four groups were flared using a sequence of diamond burs, reinforced with composite resin and restored with cast metal post-and-core, glass fiber, carbon fiber and stainless steel posts. One group was not flared and restored with cast metal post-and-core (control group). All posts were cemented with Single Bond 2 adhesive system and dual-cured RelyX ARC resin cement. Each specimen was embedded in acrylic resin and received a complete metal crown. The Universal Testing Machine EMIC-2000 was used for the mechanical test. A compressive load with a 500 Kgf load cell, at a crosshead of .5 mm. min-1, was applied at a 135-degrees angle to the long axis of the tooth until fracture occurred. One-way analysis of variance and Tukey test were performed to determine the significance of the fracture strength among the groups (P<.05). Results: The statistical analysis indicated that healthy roots with cast metal post-and-cores (Group 1) had significantly higher fracture strength: 120.02±35.34, followed by the groups of flared roots with resin reinforcement and restored with posts: cast metal post-and-cores (Group 2): 77.91±32.86; glass fiber post (Group 3): 69.60±34.44; carbon fiber post (Group 4): 48.25±22.84; and stainless steel post (Group 5): 42.26±17.52. Groups 2 to 5 were statistically similar to each other. The failure patterns varied between the groups. Group 1 showed an index of 100% of catastrophic fracture, whereas Group 4 had only 20% of root fractures. Conclusions: It can be concluded healthy teeth with complete root structure has higher fracture strength than teeth with resin-reinforced flared roots. Teeth restored with cast metal post-and-cores demonstrated higher fracture strength than teeth restored with glass fiber, carbon fiber and stainless steel posts. Teeth restored with glass fiber posts are highly resistant to fracture, whereas carbon fiber posts protect the remaining dental structure. Teeth restored with stainless steel posts show lower fracture strength and often induce root fractures.
|
5 |
Estudo in vitro da adaptação de retentores intra-radiculares fundidos, modelados com diferentes resinas acrílicas autopolimerizáveis / In vitro study of the fit of cast post and core, obtained from different acrylic resin patternsRennó, Denise Galhardo 21 September 2005 (has links)
Dentes tratados endodonticamente se encontram freqüentemente mutilados por cárie ou pelo próprio acesso ao canal. A estrutura dental remanescente necessita de tratamento especial para prevenir futuras fraturas. Quando uma grande parte da coroa dental foi perdida, é comum não haver retenção para a restauração na dentina remanescente. Nestas situações, uma restauração com retenção intracanal se faz necessária. Apenas a porção radicular pode oferecer a retenção apropriada para a instalação de uma coroa artificial estética e funcional. Diferentes técnicas podem ser usadas para a fabricação do retentor intra-radicular fundido. Neste estudo, foi escolhida a técnica direta para a confecção dos padrões de fundição em resina acrílica autopolimerizável. Usamos seis padrões metálicos com dimensões que simulavam dentes anteriores preparados para receber um retentor intra-radicular. Os condutos foram preenchidos com resina acrílica, usando um pincel bem fino, e pinos plásticos foram inseridos no interior dos canais. Após a polimerização do pino, adicionamos novas porções de resina acrílica para confecção das partes correspondentes aos núcleos. Essa técnica permite a correção de eventuais falhas, caso haja necessidade. Os padrões de fundição foram então incluídos em material de revestimento e fundidos em liga de níquel-cromo. O retentor intra-radicular fundido foi removido do revestimento e limpo. Apenas removemos os nódulos da superfície do metal, a qual recebeu, posteriormente, jateamento com óxido de alumínio. O objetivo deste estudo foi comparar a adaptação marginal de 54 retentores intra-radiculares fundidos, modelados com três resinas acrílicas autopolimerizáveis diferentes: 18 em DuraLay (Reliance Dental MFG Co., USA); 18 em Pattern Resin (GC Products, Japan); 18 em Cop Clas (Artigos Odontológicos Clássico Ltda., Brasil). Os retentores intra-radiculares fundidos foram assentados sobre os seis padrões metálicos. As fendas marginais foram observadas em microscópio eletrônico de varredura (MEV). As medições foram registradas e submetidas à análise estatística. Os resultados obtidos mostraram que: (1) Os retentores intra-radiculares fundidos obtidos de padrões de fundição modelados com a resina DuraLay mostraram-se significativamente melhor adaptados (42,31 µm ± 9,54 µm) quando comparados aos retentores intra-radiculares fundidos obtidos de padrões das resinas Pattern Resin (73,25 µm ± 32,86 µm) e Cop Clas (95,32 µm ± 45,02 µm) respectivamente; (2) Não houve diferença estatisticamente significante (p=0,273) na diferença média das fendas marginais dos retentores intra-radiculares fundidos modelados com a resina Pattern Resin e modelados com a resina Cop Clas (22,07 µm ± 13,13 µm). / Endodontically treated teeth are often mutilated by caries and access requirements. The remaining structure requires special treatment to prevent further destruction. When a large portion of the clinical crown has been lost, it is often impossible to achieve sufficient anchorage of a restoration in the remaining dentin. In such situations, a root-canal-retained restoration is required. Only the root portion can offer the needed retention for a functional and esthetic artificial crown. Different approaches can be taken to the fabrication of cast posts and cores. In this study, direct method was chosen to fashion it, by auto polymerizing acrylic resin. We used six standard metal patterns that simulate an anterior tooth prepared to receive cast post and core. Burn-out plastic patterns were fitted into the root canal and, using a fine sable hair brush, the polymer was introduced to fill the canal. After polymerization of the post, additional auto -polymerizing acrylic resin was added to form the core portion. This process can be repeated and correct if necessary. The acrylic resin patterns were then invested and casting was performed using nickel-chromium alloy. The cast was removed from investment. Cleaning was performed exclusively to remove the small positive nodules on the metal post and sandblast surface. The aim of this research was to compare the marginal fit of 54 cast posts constructed with three auto -polymerizing acrylic resins: 18 of DuraLay (Reliance Dental MFG Co., USA); 18 of Pattern Resin (GC Products, Japan); 18 of Cop Clas (Artigos Odontológicos Clássico Ltda., Brasil). The posts and cores were seated over the six standard metal patterns. Marginal discrepancies were bserved in scanning electron microscope (SEM). The measurements were registered and statistically analyzed. The results obtained showed that: (1) The cast post and core obtainedfrom DuraLay (42,31 µm ± 9,54 µm) had significant best fit than the cast post and core obtained from the others acrylic resins, Pattern Resin (73,25 µm ± 32,86 µm) and Cop Clas (95,32 µm ± 45,02 µm) respectively; (2) No significant statistic difference occur p=0,273) in the average marginal gap between the cast posts and cores obtained from Pattern Resin and Cop Class (22,07 µm ± 13,13 µm).
|
6 |
Estudo in vitro da adaptação de retentores intra-radiculares fundidos, modelados com diferentes resinas acrílicas autopolimerizáveis / In vitro study of the fit of cast post and core, obtained from different acrylic resin patternsDenise Galhardo Rennó 21 September 2005 (has links)
Dentes tratados endodonticamente se encontram freqüentemente mutilados por cárie ou pelo próprio acesso ao canal. A estrutura dental remanescente necessita de tratamento especial para prevenir futuras fraturas. Quando uma grande parte da coroa dental foi perdida, é comum não haver retenção para a restauração na dentina remanescente. Nestas situações, uma restauração com retenção intracanal se faz necessária. Apenas a porção radicular pode oferecer a retenção apropriada para a instalação de uma coroa artificial estética e funcional. Diferentes técnicas podem ser usadas para a fabricação do retentor intra-radicular fundido. Neste estudo, foi escolhida a técnica direta para a confecção dos padrões de fundição em resina acrílica autopolimerizável. Usamos seis padrões metálicos com dimensões que simulavam dentes anteriores preparados para receber um retentor intra-radicular. Os condutos foram preenchidos com resina acrílica, usando um pincel bem fino, e pinos plásticos foram inseridos no interior dos canais. Após a polimerização do pino, adicionamos novas porções de resina acrílica para confecção das partes correspondentes aos núcleos. Essa técnica permite a correção de eventuais falhas, caso haja necessidade. Os padrões de fundição foram então incluídos em material de revestimento e fundidos em liga de níquel-cromo. O retentor intra-radicular fundido foi removido do revestimento e limpo. Apenas removemos os nódulos da superfície do metal, a qual recebeu, posteriormente, jateamento com óxido de alumínio. O objetivo deste estudo foi comparar a adaptação marginal de 54 retentores intra-radiculares fundidos, modelados com três resinas acrílicas autopolimerizáveis diferentes: 18 em DuraLay (Reliance Dental MFG Co., USA); 18 em Pattern Resin (GC Products, Japan); 18 em Cop Clas (Artigos Odontológicos Clássico Ltda., Brasil). Os retentores intra-radiculares fundidos foram assentados sobre os seis padrões metálicos. As fendas marginais foram observadas em microscópio eletrônico de varredura (MEV). As medições foram registradas e submetidas à análise estatística. Os resultados obtidos mostraram que: (1) Os retentores intra-radiculares fundidos obtidos de padrões de fundição modelados com a resina DuraLay mostraram-se significativamente melhor adaptados (42,31 µm ± 9,54 µm) quando comparados aos retentores intra-radiculares fundidos obtidos de padrões das resinas Pattern Resin (73,25 µm ± 32,86 µm) e Cop Clas (95,32 µm ± 45,02 µm) respectivamente; (2) Não houve diferença estatisticamente significante (p=0,273) na diferença média das fendas marginais dos retentores intra-radiculares fundidos modelados com a resina Pattern Resin e modelados com a resina Cop Clas (22,07 µm ± 13,13 µm). / Endodontically treated teeth are often mutilated by caries and access requirements. The remaining structure requires special treatment to prevent further destruction. When a large portion of the clinical crown has been lost, it is often impossible to achieve sufficient anchorage of a restoration in the remaining dentin. In such situations, a root-canal-retained restoration is required. Only the root portion can offer the needed retention for a functional and esthetic artificial crown. Different approaches can be taken to the fabrication of cast posts and cores. In this study, direct method was chosen to fashion it, by auto polymerizing acrylic resin. We used six standard metal patterns that simulate an anterior tooth prepared to receive cast post and core. Burn-out plastic patterns were fitted into the root canal and, using a fine sable hair brush, the polymer was introduced to fill the canal. After polymerization of the post, additional auto -polymerizing acrylic resin was added to form the core portion. This process can be repeated and correct if necessary. The acrylic resin patterns were then invested and casting was performed using nickel-chromium alloy. The cast was removed from investment. Cleaning was performed exclusively to remove the small positive nodules on the metal post and sandblast surface. The aim of this research was to compare the marginal fit of 54 cast posts constructed with three auto -polymerizing acrylic resins: 18 of DuraLay (Reliance Dental MFG Co., USA); 18 of Pattern Resin (GC Products, Japan); 18 of Cop Clas (Artigos Odontológicos Clássico Ltda., Brasil). The posts and cores were seated over the six standard metal patterns. Marginal discrepancies were bserved in scanning electron microscope (SEM). The measurements were registered and statistically analyzed. The results obtained showed that: (1) The cast post and core obtainedfrom DuraLay (42,31 µm ± 9,54 µm) had significant best fit than the cast post and core obtained from the others acrylic resins, Pattern Resin (73,25 µm ± 32,86 µm) and Cop Clas (95,32 µm ± 45,02 µm) respectively; (2) No significant statistic difference occur p=0,273) in the average marginal gap between the cast posts and cores obtained from Pattern Resin and Cop Class (22,07 µm ± 13,13 µm).
|
7 |
Evaluation of fracture resistance of three post and core systems in endodontically treated teeth under loading to failure; and marginal gap measurement before and after cyclic loadingSaad, Amir N., 1979- January 2009 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / The purpose of this study was to evaluate the fracture resistance of three post and core systems in endodontically treated teeth by loading to failure, and to measure marginal gaps before and after cyclic loading.
Sixty extracted canines were assigned to three groups. The groups tested were:
1) Single cast post and core (Group CP).
2) Prefabricated metal post and composite resin core (Group MR).
3) Glass fiber post and composite resin core (Group FR).
All teeth were obturated and prepared to receive a post and core with a coping.
Thirty teeth (10 from each group) were loaded to failure, and the other 30 teeth were fatigue-loaded. The marginal gaps on the facial and lingual surface of the fatigue-loaded group were measured before and after cyclic loading.
There were two hypotheses for this study. The first was that the FR group would have less marginal gap opening on the lingual surface than the other groups.
The second was that the CP group would have a higher load at failure than the other groups.
Group CP was found to have a significantly smaller pre-loading marginal gap than group FR (p = 0.0265) and group MR (p = 0.0273), while groups FR and MR did not have a significantly different pre-loading marginal gaps (p = 0.86). Group FR had significantly less change in marginal gap than group MR (p = 0.0013). Groups CP and MR did not have significantly different changes in marginal gap (p = 0.09). Groups CP and FR did not have significantly different changes in marginal gap (p = 0.11).
The three post types did not have significantly different maximum loads to failure (p= 0.49), moments of inertia at cervical area (p = 0.75), or moments of inertia at fracture site (p=0.12).
There was no significant difference between groups CP, FR, and MR in the load-to-failure test. Group CP demonstrated the highest load-to-failure values; however, the highest load-to-failure mean was for group MR. All fractures observed in this study were catastrophic. Group FR demonstrated better stress distribution and caused no early fractures in the fatigue-loading group.
All groups demonstrated significant marginal gap changes on the lingual surface after fatigue loading; however, group FR demonstrated <45 μm marginal gap opening. In group FR, the reduced marginal gap opening was attributed to the use of Panavia 21 with the proper surface treatments to bond to the tooth structure, the resin composite, and the metal coping.
|
Page generated in 0.0708 seconds