• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 21
  • Tagged with
  • 21
  • 21
  • 12
  • 11
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efeito dos antiinflamatórios tópicos acetato de prednisolona 1%, nepafenaco 0.1% e cetorolaco de trometamina 0.4% na manutenção da midríase intra-operatória em facectomias = estudo clínico aleatorizado / Effect of preopertaive use of topical prednisolone acetate, ketorolac tromethamine, nepafenac and placebo, on the maintenance of intraoperative mydriasis during cataract surgery : a randomized trial

Zanetti, Fernando Roberte, 1983- 19 August 2018 (has links)
Orientadores: Rodrigo Pessoa Cavalcanti Lira, Carlos Eduardo Leite Arieta / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-19T07:57:39Z (GMT). No. of bitstreams: 1 Zanetti_FernandoRoberte_M.pdf: 5269678 bytes, checksum: 52bd5ded5d0f8194a3568da0d6fc7488 (MD5) Previous issue date: 2011 / Resumo: Introdução: Os Antiinflamatórios tópicos são utilizados comumente no tratamento da inflamação ocular e do edema macular cistóide relacionado a cirurgia de catarata. Tem sido sugerido o uso de antiinflamatórios antes da cirurgia, para conseguir uma melhor midriase intraoperatória. Foi relatado que quando midriase e maior do que 6 mm, a incidência de ruptura da cápsula posterior e reduzido pela metade. O objetivo deste estudo original foi comparar o efeito do uso pré-operatório do acetato de prednisolona, do cetorolaco de trometamina, do nepafenaco e de um placebo, na manutenção da midriase intra-operatória da cirurgia de catarata. Objetivo: Comparar o efeito do uso pré-operatório dos antiinflamatórios tópicos acetato de prednisolona 1%, nepafenaco 0.1% e cetorolaco de trometamina 0.4%, alem de um placebo, na manutenção da midriase intraoperatoria durante a cirurgia de catarata. Desenho: Ensaio clinico aleatorizado, mascarado, realizado em um único centro. Métodos: E um estudo composto por 140 pacientes submetidos a cirurgia de facoemulsificação de catarata. Os pacientes (35 voluntários por grupo) foram aleatorizados para receber o placebo (carboximetilcelulose de sódio 0,5%), acetato de prednisolona 1%, cetorolaco de trometamina 0,4% e o nepafenaco 0,1%. Os colírios eram administrados 3 vezes ao dia e iniciados 48 horas antes da cirurgia.. A medida do tamanho da pupila foi realizada pelo cirurgião usando um compasso nos seguintes momentos: antes da secção da córnea e ao final da cirurgia. O desfecho primário foi avaliar a eficácia de cada medicamento em inibir a miose intraoperatoria (pupilas > 6mm, no final da cirurgia). O desfecho secundário foi obter pupilas > 6mm no inicio da cirurgia. Resultados: O numero de pacientes no grupo da prednisolona (29/35), no grupo do nepafenaco (31/35) e no grupo do cetorolaco (30/35) com diâmetro pupilar > 6 mm foi maior do que no grupo placebo em relação a manutenção da midriase intraoperatoria (19/35 - P =. 003). Não houve diferença estatística entre o grupo da prednisolona, do nepafenaco e do cetorolaco na manutenção da midriase intraoperatória (P =. 791). Não houve complicações durante a cirurgia ou efeitos adversos relacionados com o uso pré-operatório do colírio. Conclusão: O uso pré-operatório da prednisolona, do cetorolaco e do nepafenaco foi eficaz na manutenção midriase intraoperatória quando comparado com o placebo / Abstract: Introduction: Topical anti-inflammatory drugs are commonly used in the management of ocular inflammation and cystoid macular edema related to cataract surgery. It has been suggested the use of anti-inflammatory drugs before surgery, to achieve better intraoperative mydriasis. It was reported that, when mydriasis is greater than 6 mm, the incidence of posterior capsule rupture is reduced by half. The objective of the original study was to compare the effect of preoperative use of topical anti-inflammatory prednisolone acetate, ketorolac tromethamine, nepafenac and placebo, in the maintenance of intraoperative mydriasis in cataract surgery. Purpose: To compare the effects of preoperative use of topical anti-inflammatory prednisolone acetate, ketorolac tromethamine, nepafenac and placebo, on the maintenance of intraoperative mydriasis during cataract surgery. Design: Randomized clinical trial, single-center and masked. Methods: This study comprised 140 patients scheduled for cataract surgery. Patients (35 in each group) were randomized to receive placebo, prednisolone acetate, ketorolac tromethamine 0.4 % or nepafenac. These eye drops were administered three times daily for the two days prior to surgery. The pupillary diameters were measured by the surgeon using a compass prior to the corneal section and at the end of surgery. The primary outcome was the number of patients with pupil > 6 mm at the end of the surgery; the secondary outcome was the number of patients with pupil > 6 mm at the beginning of the surgery. Results: All the patients achieved pupil > 6 mm at the beginning of the surgery. The number of patients in the prednisolone (29/35), nepafenac (31/35) and ketorolac (30/35) groups with pupil > 6 mm was greater than in the placebo group in the maintenance of intraoperative mydriasis (19/35 - P =.003 - Table 2). There was no statistical difference among the prednisolone, nepafenac and ketorolac groups in the maintenance of intraoperative mydriasis (P =.791). There were no complications during surgery or related to the preoperative use of the eye drops. Conclusion: Preoperative use of ketorolac, prednisolone and nepafenac was effective in maintaining intraoperative mydriasis when compared with placebo / Mestrado / Oftalmologia / Mestre em Ciências Médicas
2

Análise comparativa de dois viscoelásticos dispersivos na facoemulsificação em cães portadores de catarata

Chiurciu, João Leandro Vera [UNESP] 29 February 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:09Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-02-29Bitstream added on 2014-06-13T19:25:57Z : No. of bitstreams: 1 chiurciu_jlv_dr_botfmvz.pdf: 349241 bytes, checksum: bd5d442bec2c4a00b188c9600c29d72f (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Com o trabalho, teve-se por objetivo analisar individual e comparativamente o desempenho de dois viscoelásticos, hialuronato de sódio 3% associado ao sulfato de condroitina 4% e hidroxipropilmetilcelulose 2%, frente à facoemulsificação em cães portadores de catarata madura, por meio da avaliação das alterações clínicas e variações das células endoteliais, espessura corneana e pressão intra-ocular (PIO). Foram utilizados 20 cães distribuídos em dois grupos, cada qual utilizando um dos viscoelásticos. A técnica cirúrgica adotada a foi facoemulsificação bimanual. As avaliações clínicas e tonométricas foram efetuadas antes e após o ato cirúrgico , em 1, 7, 14, 21, 28 e 60 dias de pós-operatório e a microscopia especular, antes e após 7, 28 e 60 dias. Foi efetuada a correlação entre tempo de ultra-som utilizado e as variáveis estudadas, bem como das variáveis entre sí. Utilizando-se hidroxipropilmetilcelulose 2%, ocorreu opacidade corneana, formação de fibrina e hiperemia conjuntival mais freqüentemente e de maior intensidade no período inicial. Não houve diferença estatística entre os grupos na variação da PIO, com exceção da medida feita aos 14 dias, quando foi significativamente maior com o uso de hialuronato de sódio 3% e sulfato de condroitina 4%. Não houve diferença estatística entre os grupos nos parâmetros relacionados ao endotélio. Correlação de concordância significativa foi observada somente entre densidade e área celular endotelial. O uso de hialuronato de sódio 3% e sulfato de condroitina 4% é vantajoso nos casos de densidade celular endotelial próxima ao limite inferior de normalidade. / The study aimed to assess the clinical changes and variations of the endothelial cells, corneal thickness and intra-ocular pressure (IOP) front to the facoemulsificação on dogs carriers of cataract, using viscoelastic substances the base of sodium hyaluronate 3% and sodium chondroitin sulfate 4% and comparing it with hidroxipropilmetilcelulose 2%. Twenty dogs were used distributed in two equal groups, each using one of viscoelástic materials. The surgical technique used was phaco bimanual. The clinical and tonometric evaluations were made before and after 1, 7, 14, 21, 28 and 60 days of surgery and specular microscopy before and after 7, 28 and 60 days. Correlation between time of used ultrasound and the studied variable, as well as of the variables among itself was effected. Hidroxipropilmetilcelulose 2% developed more incidence frequent and of bigger intensity in the corneal opacity, formation of fibrin and conjunctival hyperemia in the initial period. There was no statistical difference between the groups in the variation in IOP, except to 14 day, which was significantly higher with the use of sodium hyaluronate 3% and chondroitin sulfate 4%. There was no statistical difference between the groups in the parameters related to the endothelium, with slight decrease in endothelial cell density and increase of cell area with the use of hydroxypropyl 2%. Significant correlation was only observed between density and endothelial cellular area. The use of sodium hyaluronate 3% and chondroitin sulfate 4% is advantageous in cases of endothelial cell density near to the lower limit of normality.
3

Estudo prospectivo do desenvolvimento biométrico de olhos com catarata congênita e do desenvolvimento

Prado, Rodrigo Bueno do [UNESP] 20 March 2014 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:20Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-03-20Bitstream added on 2015-01-26T13:30:40Z : No. of bitstreams: 1 000788564.pdf: 564163 bytes, checksum: 1d633601c854f1fd8cbce36c05aca659 (MD5) / OBJETIVO. Avaliar o comprimento axial (AL), profundidade da câmara anterior (ACD) e espessura do cristalino (LT) de olhos de crianças a termo com catarata congênita e do desenvolvimento não complicada e fornecer estimativas específicas por idade. MÉTODO. Estudo retrospectivo de crianças submetidas à facectomia entre junho de 2011 e janeiro de 2014. Foram incluídas crianças com catarata não complicada sem patologias oculares e idade inferior a dez anos. Dados biométricos foram obtidos com biômetro de imersão. Procedeu-se a análise estatística dos dados e a regressão linear com o logaritmo da idade para modelar a relação do AL com a idade. RESULTADOS. Todos os olhos de 41 crianças foram incluídos na análise, com média de idade de 37,3 meses. A idade teve relação significativa com as medidas de AL (p<0,01). Eram 23 do sexo masculino (56%). Tiveram média de idade de 32,1 meses no sexo masculino e 44 meses no feminino, com baixa relação de AL segundo o sexo (p>0,05). As médias e desvio padrão de AL em olhos com catarata unilateral (n=16) e um dos olhos aleatoriamente selecionado (n=25) nos casos bilaterais foram de 20,37 mm ± 2,11 e 20,54 mm ± 1,97 respectivamente. Medidas de AL tiveram relação linear positiva com ACD e LT. Olhos com catarata unilateral tiveram AL menor que olhos sadios contralaterais. CONCLUSÃO. Medidas de AL alteram significativamente com a idade, principalmente nos 6 primeiros meses. O estudo prediz valores de AL nas diversos grupos etários, contribuindo para o cálculo do poder de lente intraoculares em crianças / PURPOSE. To evaluate the axial length (AL), anterior chamber depth (ACD) and lens thickness (LT) of eyes of full-term infants with congenital and development cataracts uncomplicated and provide specific estimates by age. METHOD. Retrospective study of children undergoing cataract surgery between June 2011 and January 2014. Children with uncomplicated cataract without ocular pathologies and less than ten years old were included. Biometric data were obtained with immersion biometer. Proceeded to statistical analysis and linear regression with logarithm of age to model the relationship of AL with age. RESULTS. All eyes of 41 children were included in the analysis, with a mean age of 37.3 months. Age had a significant relationship with measures of AL (p< 0.01). 23 were male (56%). Had a mean age of 32.1 months for males and 44 months in females, with low ratio of AL according to gender (p>0.05). The mean and standard deviation of AL in eyes with unilateral cataract surgery (n=16) and randomly selected one eye in bilateral cases (n=25) were 20.37 ± 2.11 mm and 20.54 mm ± 1.97 respectively. AL measures had a positive linear relationship with ACD and LT . Eyes with unilateral cataract had smaller AL than the contralateral healthy eyes. CONCLUSION. AL measures change significantly with age, especially in the first six months. The study predicts values of AL in various age groups, contributing to the calculation of intraocular lens power in children
4

Avaliação ultrassonográfica do bulbo ocular em cães submetidos à facectomia por facoemulsificação com ou sem implante de lente intraocular

Pavan, Priscila Teodoro [UNESP] 29 June 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:45Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-06-29Bitstream added on 2014-06-13T19:30:17Z : No. of bitstreams: 1 pavan_pt_me_botfmvz.pdf: 3799267 bytes, checksum: 720cd0e9fdd18a21ac4ccee753679f56 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O exame ultrassonográfico tem sido utilizado para diagnóstico das doenças oftálmicas humanas desde 1956, já em Medicina Veterinária o seu uso foi somente descrito em 1968; ainda tem sido muito pouco empregado para auxílio no pósoperatório de catarata, onde possui grande importância no diagnóstico de alterações decorrentes da facectomia. O presente trabalho teve por objetivo descrever e comparar as alterações ultrassonográficas encontradas em bulbos oculares de cães submetidos à facectomia por facoemulsificação, com ou sem implante de lente intraocular (LIO), no intuito de auxiliar no diagnóstico de possíveis alterações decorrentes do procedimento cirúrgico e do implante da LIO, bem como sua correspondência com alterações clínicas. Foram utilizados 19 cães machos e fêmeas portadores de catarata já operados, de várias raças e idades, saudáveis, não diabéticos e submetidos à facectomia por facoemulsificação, resultando em 21 bulbos oculares avaliados. Os animais inicialmente foram submetidos a exame oftálmico completo, em ambiente de baixa luminosidade, e em seguida ao exame ultrassonográfico. Foram constituídos três grupos: um de 11 bulbos oculares, CA (cães afácicos), outro de 05 bulbos oculares PP (cães pseudofácicos com implante de duas LIOs em piggyback) e outro PL de 05 bulbos oculares com implante de uma LIO veterinária de 41 D. O exame ultrassonográfico foi realizado sob administração tópica de colírio anestésico oftálmico1, com transdutor linear multifrequencial de 6 a 10 MHz pelas técnicas transpalpebral e corneal. Clinicamente, foram observadas diferentes alterações, dentre elas: luxação da LIO, descolamento de retina, hialose asteróide e degeneração vítrea que foram, posteriormente, confirmadas e classificadas pelo exame ultrassonográfico. Os grupos não mostraram... / The ultrasound has been used for diagnosis of human ophthalmic disease since 1956, veterinary medicine in their use was only described in 1968. The present study aims to describe and compare the ultrasonographic alterations encountered in dogs which underwent facectomy through facoemulsification with or without intraocular lens implant (IOL), in an attempt to assist the diagnosis of possible alterations due to the surgical procedure and IOL implantation, as well as their relation to corresponding clinical signs. The study group was composed by 19 male and female healthy, non-diabetic dogs of various breeds and ages, which had already had surgery for cataract, adding up to the evaluation of 21 ocular bulbs. The animals were initially submitted to complete ophthalmological exams, in a dim environment which preceded the sonogram. Subsequently, the subjects were divided into three distinct groups: Aphakic dogs (CA), pseudophakic dogs implanted with two piggyback IOLs (PP) and dogs implanted with a 41D veterinary IOL (PL), which consisted of 11, 05 and 5 ocular bulbs, respectively. The ultrasound was carried under the topic administration of an anesthetic eye drop1, with a multi frequency linear transducer of 6 to 10 MHz through the transpalpebral and transcorneal technique. The clinical alterations observed were luxation of the IOL, retinal dislocation, asteroid hyalosis, and vitreous degeneration. No statistic difference in the descriptive measures of the variables regarding the ocular axis and the anterior chamber was found, however, when comparing measurements of the cilliar body and the vitreal chamber, the PP group... (Complete abstract click electronic access below)
5

Avaliação ultrassonográfica do bulbo ocular em cães submetidos à facectomia por facoemulsificação com ou sem implante de lente intraocular /

Pavan, Priscila Teodoro. January 2011 (has links)
Orientador: José Joaquim Titton Ranzani / Banca: Maria Jaqueline Mamprim / Banca: Geórgia Nadalini Rodrigues / Resumo: O exame ultrassonográfico tem sido utilizado para diagnóstico das doenças oftálmicas humanas desde 1956, já em Medicina Veterinária o seu uso foi somente descrito em 1968; ainda tem sido muito pouco empregado para auxílio no pósoperatório de catarata, onde possui grande importância no diagnóstico de alterações decorrentes da facectomia. O presente trabalho teve por objetivo descrever e comparar as alterações ultrassonográficas encontradas em bulbos oculares de cães submetidos à facectomia por facoemulsificação, com ou sem implante de lente intraocular (LIO), no intuito de auxiliar no diagnóstico de possíveis alterações decorrentes do procedimento cirúrgico e do implante da LIO, bem como sua correspondência com alterações clínicas. Foram utilizados 19 cães machos e fêmeas portadores de catarata já operados, de várias raças e idades, saudáveis, não diabéticos e submetidos à facectomia por facoemulsificação, resultando em 21 bulbos oculares avaliados. Os animais inicialmente foram submetidos a exame oftálmico completo, em ambiente de baixa luminosidade, e em seguida ao exame ultrassonográfico. Foram constituídos três grupos: um de 11 bulbos oculares, CA (cães afácicos), outro de 05 bulbos oculares PP (cães pseudofácicos com implante de duas LIOs em piggyback) e outro PL de 05 bulbos oculares com implante de uma LIO veterinária de 41 D. O exame ultrassonográfico foi realizado sob administração tópica de colírio anestésico oftálmico1, com transdutor linear multifrequencial de 6 a 10 MHz pelas técnicas transpalpebral e corneal. Clinicamente, foram observadas diferentes alterações, dentre elas: luxação da LIO, descolamento de retina, hialose asteróide e degeneração vítrea que foram, posteriormente, confirmadas e classificadas pelo exame ultrassonográfico. Os grupos não mostraram... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The ultrasound has been used for diagnosis of human ophthalmic disease since 1956, veterinary medicine in their use was only described in 1968. The present study aims to describe and compare the ultrasonographic alterations encountered in dogs which underwent facectomy through facoemulsification with or without intraocular lens implant (IOL), in an attempt to assist the diagnosis of possible alterations due to the surgical procedure and IOL implantation, as well as their relation to corresponding clinical signs. The study group was composed by 19 male and female healthy, non-diabetic dogs of various breeds and ages, which had already had surgery for cataract, adding up to the evaluation of 21 ocular bulbs. The animals were initially submitted to complete ophthalmological exams, in a dim environment which preceded the sonogram. Subsequently, the subjects were divided into three distinct groups: Aphakic dogs (CA), pseudophakic dogs implanted with two piggyback IOLs (PP) and dogs implanted with a 41D veterinary IOL (PL), which consisted of 11, 05 and 5 ocular bulbs, respectively. The ultrasound was carried under the topic administration of an anesthetic eye drop1, with a multi frequency linear transducer of 6 to 10 MHz through the transpalpebral and transcorneal technique. The clinical alterations observed were luxation of the IOL, retinal dislocation, asteroid hyalosis, and vitreous degeneration. No statistic difference in the descriptive measures of the variables regarding the ocular axis and the anterior chamber was found, however, when comparing measurements of the cilliar body and the vitreal chamber, the PP group... (Complete abstract click electronic access below) / Mestre
6

Estudo prospectivo do desenvolvimento biométrico de olhos com catarata congênita e do desenvolvimento /

Prado, Rodrigo Bueno do. January 2014 (has links)
Orientador: Antônio Carlos Lottelli Rodrigues / Banca: Carlos Roberto Padovani / Banca: André Messias / Resumo: OBJETIVO. Avaliar o comprimento axial (AL), profundidade da câmara anterior (ACD) e espessura do cristalino (LT) de olhos de crianças a termo com catarata congênita e do desenvolvimento não complicada e fornecer estimativas específicas por idade. MÉTODO. Estudo retrospectivo de crianças submetidas à facectomia entre junho de 2011 e janeiro de 2014. Foram incluídas crianças com catarata não complicada sem patologias oculares e idade inferior a dez anos. Dados biométricos foram obtidos com biômetro de imersão. Procedeu-se a análise estatística dos dados e a regressão linear com o logaritmo da idade para modelar a relação do AL com a idade. RESULTADOS. Todos os olhos de 41 crianças foram incluídos na análise, com média de idade de 37,3 meses. A idade teve relação significativa com as medidas de AL (p<0,01). Eram 23 do sexo masculino (56%). Tiveram média de idade de 32,1 meses no sexo masculino e 44 meses no feminino, com baixa relação de AL segundo o sexo (p>0,05). As médias e desvio padrão de AL em olhos com catarata unilateral (n=16) e um dos olhos aleatoriamente selecionado (n=25) nos casos bilaterais foram de 20,37 mm ± 2,11 e 20,54 mm ± 1,97 respectivamente. Medidas de AL tiveram relação linear positiva com ACD e LT. Olhos com catarata unilateral tiveram AL menor que olhos sadios contralaterais. CONCLUSÃO. Medidas de AL alteram significativamente com a idade, principalmente nos 6 primeiros meses. O estudo prediz valores de AL nas diversos grupos etários, contribuindo para o cálculo do poder de lente intraoculares em crianças / Abstract: PURPOSE. To evaluate the axial length (AL), anterior chamber depth (ACD) and lens thickness (LT) of eyes of full-term infants with congenital and development cataracts uncomplicated and provide specific estimates by age. METHOD. Retrospective study of children undergoing cataract surgery between June 2011 and January 2014. Children with uncomplicated cataract without ocular pathologies and less than ten years old were included. Biometric data were obtained with immersion biometer. Proceeded to statistical analysis and linear regression with logarithm of age to model the relationship of AL with age. RESULTS. All eyes of 41 children were included in the analysis, with a mean age of 37.3 months. Age had a significant relationship with measures of AL (p< 0.01). 23 were male (56%). Had a mean age of 32.1 months for males and 44 months in females, with low ratio of AL according to gender (p>0.05). The mean and standard deviation of AL in eyes with unilateral cataract surgery (n=16) and randomly selected one eye in bilateral cases (n=25) were 20.37 ± 2.11 mm and 20.54 mm ± 1.97 respectively. AL measures had a positive linear relationship with ACD and LT . Eyes with unilateral cataract had smaller AL than the contralateral healthy eyes. CONCLUSION. AL measures change significantly with age, especially in the first six months. The study predicts values of AL in various age groups, contributing to the calculation of intraocular lens power in children / Mestre
7

Análise comparativa de dois viscoelásticos dispersivos na facoemulsificação em cães portadores de catarata /

Chiurciu, João Leandro Vera. January 2008 (has links)
Resumo: Com o trabalho, teve-se por objetivo analisar individual e comparativamente o desempenho de dois viscoelásticos, hialuronato de sódio 3% associado ao sulfato de condroitina 4% e hidroxipropilmetilcelulose 2%, frente à facoemulsificação em cães portadores de catarata madura, por meio da avaliação das alterações clínicas e variações das células endoteliais, espessura corneana e pressão intra-ocular (PIO). Foram utilizados 20 cães distribuídos em dois grupos, cada qual utilizando um dos viscoelásticos. A técnica cirúrgica adotada a foi facoemulsificação bimanual. As avaliações clínicas e tonométricas foram efetuadas antes e após o ato cirúrgico , em 1, 7, 14, 21, 28 e 60 dias de pós-operatório e a microscopia especular, antes e após 7, 28 e 60 dias. Foi efetuada a correlação entre tempo de ultra-som utilizado e as variáveis estudadas, bem como das variáveis entre sí. Utilizando-se hidroxipropilmetilcelulose 2%, ocorreu opacidade corneana, formação de fibrina e hiperemia conjuntival mais freqüentemente e de maior intensidade no período inicial. Não houve diferença estatística entre os grupos na variação da PIO, com exceção da medida feita aos 14 dias, quando foi significativamente maior com o uso de hialuronato de sódio 3% e sulfato de condroitina 4%. Não houve diferença estatística entre os grupos nos parâmetros relacionados ao endotélio. Correlação de concordância significativa foi observada somente entre densidade e área celular endotelial. O uso de hialuronato de sódio 3% e sulfato de condroitina 4% é vantajoso nos casos de densidade celular endotelial próxima ao limite inferior de normalidade. / Abstract: The study aimed to assess the clinical changes and variations of the endothelial cells, corneal thickness and intra-ocular pressure (IOP) front to the facoemulsificação on dogs carriers of cataract, using viscoelastic substances the base of sodium hyaluronate 3% and sodium chondroitin sulfate 4% and comparing it with hidroxipropilmetilcelulose 2%. Twenty dogs were used distributed in two equal groups, each using one of viscoelástic materials. The surgical technique used was phaco bimanual. The clinical and tonometric evaluations were made before and after 1, 7, 14, 21, 28 and 60 days of surgery and specular microscopy before and after 7, 28 and 60 days. Correlation between time of used ultrasound and the studied variable, as well as of the variables among itself was effected. Hidroxipropilmetilcelulose 2% developed more incidence frequent and of bigger intensity in the corneal opacity, formation of fibrin and conjunctival hyperemia in the initial period. There was no statistical difference between the groups in the variation in IOP, except to 14 day, which was significantly higher with the use of sodium hyaluronate 3% and chondroitin sulfate 4%. There was no statistical difference between the groups in the parameters related to the endothelium, with slight decrease in endothelial cell density and increase of cell area with the use of hydroxypropyl 2%. Significant correlation was only observed between density and endothelial cellular area. The use of sodium hyaluronate 3% and chondroitin sulfate 4% is advantageous in cases of endothelial cell density near to the lower limit of normality. / Orientador: Cláudia Valéria Seullner Brandão / Coorientador: Antônio Carlos Lottelli Rodrigues / Banca: José Joaquim Titton Ranzani / Banca: José Luiz Laus / Banca: Antônio Felipe Paulino Figueiredo Wouk / Banca: Silvana Artioli Schellini / Doutor
8

Melhora da estereoacuidade : uma indicação para capsulotomia unilateral : desenvolvimento de um modelo semiologico

Senne, Firmani Mello Bento de 08 August 2001 (has links)
Orientador : Marilisa Nano Costa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-07-29T01:18:31Z (GMT). No. of bitstreams: 1 Senne_FirmaniMelloBentode_M.pdf: 8892502 bytes, checksum: f00112dc60438b5efb50ff76a2500089 (MD5) Previous issue date: 2001 / Resumo: Este estudo foi realizado com o objetivo de desenvolver um modelo semiológico para determinar se a estereoacuidade medida pelo teste de Titmus pode ser um indicador objetivo de melhora funcional após a capsulotomia em casos unilaterais de opacificação de cápsula cristaliniana posterior. Catorze pacientes com opacificação de cápsula posterior unilateral pós-facectomia com implantação de lente intra-ocular (6 pacientes fácicos e 8 pseudofácicos no olho contralateral) foram estudados prospectivamente. A acuidade visual variou de 0,05 a 0,5 no olho com opacificação de cápsula posterior e de 0,7 a 1,0 no olho contralateral (sem opacificação de cápsula posterior). Todos os pacientes foram submetidos a capsulotomia posterior com Neodymium: Yttrium-Aluminum-Garnet (Nd:YAG) laser. A estereoacuidade pré e pós-capsulotomia foi medida pelo teste de Titmus. A análise estatística foi efetuada usandose testes não paramétricos (Wilcoxon e Spearman). Houve melhora significativa da estereoacuidade após a capsulotomia posterior com Nd:YAG laser nos pacientes da população estudada. O trabalho revelou dados preliminares para análise do efeito da capsulotomia posterior em casos de opacificação de cápsula unilateral na estereoacuidade, demonstrando que a catarata secundária reduz a visão estereoscópica e concluindo que a estereoacuidade, ao lado da acuidade visual, pode ser um parâmetro objetivo de indicação de capsulotomia em casos unilaterais de opacificação da cápsula posterior / Abstract: This study was designed to develop a semiologic model to determine whether stereoacuity is an objective mdicator of functional improvement following unilateral secondary capsulotomy. Fourteen patients with unilateral posterior capsule opacification post cataract surgery with implantation of intraocular lens (6 phakic, 8pseudophakic m contralateral eye) were studied prospectively. Visual acuity ranged from 0,05 to 0,5 m the eye with posterior capsule opacification and ranged from 0,7 to 1,0m contralateral eye. All patients had Neodymium: Yttrium-Alummum-Garnet (Nd:YAG) laser capsulotomy. Stereoacuity was measured before and afier capsulotmy by Titmus testo Nonparametric Spearman rank correlation and Wilcoxon rank tests were used for analysis. Stereoacuity improved afier capsulotomy m alI patients. The visual acuity m the eye with posterior capsule opacification did not correlate with stereoacuity afier capsulotomy. This study demonstrated that posterior capsule opacification reduces the depth vision and concluded that stereoacuity may provide an mdication for unilateral capsulotomy / Mestrado / Oftalmologia / Mestre em Ciências Médicas
9

Sensibilidade ao contraste e qualidade de vida na indicação de cirurgia de catarata

Monsanto, Andre Raposo 02 April 2004 (has links)
Orientadores: Carlos Eduardo Leite Arieta, Djalma de Carvalho Moreira Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-03T20:26:19Z (GMT). No. of bitstreams: 1 Monsanto_AndreRaposo_M.pdf: 2808481 bytes, checksum: aeae1247b94fc521a160f2d841810ac8 (MD5) Previous issue date: 2004 / Resumo: Objetivo: Avaliar os resultados de um teste de Sensibilidade ao Contraste (CSV 1000) e de um Questionário de Qualidade de Vida relacionado à função visual (NEI-VFQ 25) em pacientes com catarata senil e Acuidade Visual Corrigida (AV C/C) no melhor olho entre 20/20 e 20/63. Avaliar também as relações entre estes resultados e sua aplica­ção na indicação cirúrgica da catarata. Material e Método: Noventa e seis pacientes com catarata senil foram avaliados com os testes citados, divididos em três grupos de 32 pacientes segundo sua AV C/C no me­lhor olho. No primeiro grupo foram alocados os pacientes com AV 20/20 e 20/25, no segundo 20/32 e 20/40 e no terceiro 20/50 e 20/63. Resultado: Não houve diferença estatisticamente significativa nos resultados do questionário de Qualidade de Vida (QV) entre os três grupos (p=0,421604). Houve diferença significativa na avaliação da Sensibilidade ao Contraste (Se) entre os três grupos (p<O,OOOOOl) e houve correlação entre a classificação da catarata e o resultado deste teste de SC (p=O,OOOOOl). Houve ainda diferença significativa na classificação da cata­rata entre os três grupos, para todos os aspectos estudados pelo LOCS lU (p<O,OOOOO 1 até p=0,045161). Conclusão: O aparelho CSV 1000 se mostrou adequado para identificar as alterações visuais de Sensibilidade ao Contraste nos pacientes portadores de catarata senil e AV C/C entre 20/20 e 20/63, mantendo-se entre uma e duas linhas de visão abaixo dos valores da AV. O questionário de Qualidade de Vida NEI-VFQ 25 não se mostrou ade­quado para avaliar estes pacientes, que têm AV acima do intervalo definido como bai­xa visão pela OMS (entre 20/70 e 20/400). É possível porém que o tamanho da amos­ tra populacional utilizado não tenha permitido a avaliação definitiva deste dado. Estes resultados podem auxiliar na reflexão da questão cada vez mais complexa do melhor momento da indicação da facectomia para um determinado paciente, deci­são afetada pelo acesso aos serviços de saúde, pela necessidade profissional do paci­ente e pelos resultados mais previsíveis obtidos atualmente com o uso da Facoemulsi­ficação, entre outros fatores / Abstract: The abstract is available with the full electronic digital document / Mestrado / Oftalmologia / Mestre em Ciências Médicas
10

Taxa de crescimento axial pós-operatório de olhos com catarata congênita e do desenvolvimento submetidos a facectomia com implante de lente intra-ocular /

Andrade, Guilherme Pessoni de. January 2015 (has links)
Orientador: Antônio Carlos Lottelli Rodrigues / Banca: Wallace Chamon Alves de Siqueira / Banca: Carlos Roberto Padovani / Resumo: OBJETIVO: Estabelecer, para olhos com catarata congênita e do desenvolvimento, modelos matemáticos para o cálculo da taxa de crescimento axial diário (TCA) e cálculo do comprimento axial (Axl) em qualquer idade futura, a partir da idade e do Axl medido, no momento da cirurgia. MÉTODOS: Estudo retrospectivo de crianças submetidas à facectomia com implante de LIO entre janeiro de 2011 a janeiro de 2014. Foram incluídas crianças com catarata não complicada sem patologias oculares e idade inferior a dez anos. Dados biométricos foram obtidos com biômetro de imersão. Procedeu-se a análise estatística dos dados e estabeleceu-se fórmulas matemáticas para cálculo da TCA e Axl. RESULTADOS: Foram operados 54 olhos de 33 crianças sendo 19 masculinos (57,58%) e 14 femininos (42,42%). Dos 33 casos analisados, 12 eram cataratas unilaterais (36,37%) e 21 eram cataratas bilaterais (63,63%). Nos casos de catarata bilateral utilizou-se apenas os dados do olho direito de cada criança. A amostra foi dividida em 3 grupos (cataratas unilaterais e bilaterais, cataratas unilaterais, cataratas bilaterais) e para cada grupo foi estabelecido uma fórmula matemática para cálculo da TCA e Axl. CONCLUSÕES: O presente estudo propõe uma nova maneira de abordagem no cálculo da LIO, não baseada em resultados refracionais pós-operatório mas em uma taxa de crescimento diário (TCA). As equações geradas permitem estabelecer a taxa de crescimento diária em qualquer idade e principalmente a permitem "prever" Axl futuro a partir de um Axl inicial medido. Não é possível concluir pelo presente estudo que o método proposto é superior a outros métodos de estimação do crescimento ocular. Estudos comparativos entre eles serão necessários para avaliar esta precisão / Abstract: PURPOSE: Establish, for the eyes with congenital and development cataract, mathematical models to calculate the daily axial growth rate (AGR) and calculation of the axial length (Axl) in any future age, from the age and Axl measured at the time of surgery. METHODS: Retrospective study of children undergoing cataract extraction with IOL implantation between January 2011 and January 2014. We included children with uncomplicated cataract without eye diseases and the age of ten years. Biometric data were obtained with plunge biometer. We carried out the statistical analysis of data and established mathematical formulas to calculate the AGR and Axl. RESTULTS: Were operated on 54 eyes of 33 children, 19 male (57.58%) and 14 female (42.42%). Of the 33 cases analyzed, 12 were unilateral cataracts (36,37%) and 21 were bilateral cataracts (63.63%). In cases of bilateral cataracts was used only the right eye of the data of every child. The sample was divided into 3 groups (unilateral and bilateral cataracts, unilateral cataracts, bilateral cataracts) and for each group was established a mathematical formula to calculate the AGR and Axl. CONCLUSIONS: This study proposes a new way to approach the calculation of IOL, not based on postoperative refractive results but on a daily growth rate (AGR). The generated equations for establishing the daily growth rate at any age and especially to allow "predict" Axl future from a measured initial Axl. Can not complete with this study that the proposed method is superior to other methods of estimation of eye growth. Comparative studies between them will be needed to assess this accurately / Mestre

Page generated in 0.0924 seconds