• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Analyse numérique de la réponse des pieux sous sollicitations latérales

Hazzar, Lassaad January 2014 (has links)
Résumé : Afin de contribuer dans la réponse latérale des pieux sous sollicitations latérales et notamment prendre en compte des plusieurs paramètres en relation avec les pieux (matériau, diamètre, rigidité, inclinaison) et le sol (nature, rigidité), des analyses numériques en différences finies 2D et 3D ont été réalisées en considérant des pieux chargés latéralement et ancrés dans des sols sableux, argileux et même sableux-argileux. Des modèles numériques simulés avec les codes en différences finies FLAC pour l’analyse 2D et FLAC[indice supérieur 3D] pour l’analyse 3D ont été inspirés des modèles de pieux réduits et en vraie grandeur, faisant l’objet de publications. Des enregistrements du déplacement latéral ou/et de la capacité latérale ou/et du moment fléchissant des pieux considérés ont été pris lors de ces essais. Ces modèles numériques ont été validés à travers diverses comparaisons entre les mesures, les calculs de FLAC et/ou FLAC3D et dans des cas les calculs d’autres méthodes utilisées dans la pratique. Une comparaison entre l’analyse 2D et l’analyse 3D de la réponse latérale d’un pieu rigide chargé latéralement dans un sol cohérent, a été réalisée dans le but de connaître les limites de l’analyse 2D et la possibilité de corréler ses résultats à ceux de l’analyse 3D. L’influence de la charge verticale sur la réponse latérale (capacité latérale et moment fléchissant maximal) d’un pieu en béton, chargé latéralement dans des sols sableux et argileux, a été étudiée avec une analyse numérique 3D. Il a été démontré que pour le cas des sols sableux, la charge verticale n’a pas un effet considérable sur la réponse latérale des pieux soumis à des charges latérales. Par contre, la charge verticale conduit à une diminution significative de la capacité latérale des pieux dans des sols argileux. Il est également constaté que l'influence des charges verticales sur la réponse latérale du pieu installé dans une argile surconsolidée avec une résistance au cisaillement non drainée proportionnelle à la profondeur et un OCR variant de 1,5 à 4,0 est très différent de celle correspondante à une résistance au cisaillement non drainée constante quelle que soit la valeur d’OCR. Des analyses 3D ont été, également, effectuées pour étudier la réponse latérale de pieux inclinés et chargés latéralement. La capacité latérale des pieux inclinés dans les sols sableux est considérablement augmentée avec l’augmentation de la valeur de l’inclinaison du pieu correspondante à la direction opposée à la direction de la charge latérale, et la densité du sable. Mais lorsque la direction de l’inclinaison du pieu et la même que celle correspondante à la charge latérale, cette capacité latérale est légèrement à modérément augmentée tout dépendamment de la valeur et le signe de l'angle ainsi que de la densité du sable. L’influence de l’angle d’inclinaison associé avec la charge verticale sur la capacité latérale de pieux inclinés est aussi très importante pour les sols sableux. Pour les sols argileux, l'influence de l'angle d’inclinaison sur la capacité latérale dépend seulement de l'angle d’inclinaison. En effet, la capacité latérale est modérément augmentée. Par contre, L'effet combiné de l’angle et la charge verticale est assez important. // Abstract : This thesis pertains to numerical analyses conducted primarily to evaluate the lateral response of piles and the contribution of several parameters related to piles (e.g., material, diameter, stiffness, inclination) and the soil (e.g., type, rigidity). Numerical finite differences analysis in 2D and 3D have been performed modelizing laterally loaded piles in sandy, clayey, and even sandy-clayey soils. Numerical models, simulated with finite difference codes FLAC for analysis in 2D and FLAC[superscript 3D] for 3D analysis, were inspired from experimental laboratory and full scale models available in literature. Measurements of lateral deflection and/or lateral capacity and/or bending moment of tested piles were recorded during these tests. These numerical models have been validated through comparison between the various measurements, predictions with FLAC and/or FLAC3D and for some cases the calculations with other methods used in practice. Comparison between 2D and 3D analyses of the response of laterally loaded rigid piles in cohesive soils, was performed in order to investigate the 2D analysis limitations and the possibility of correlating the 2D results with those of 3D analysis. A series of 3D finite differences analyses is also conducted to evaluate the influence of vertical loads on the lateral response of pile foundations. Numerical results have shown that the lateral resistance of the piles does not appear to vary considerably with the vertical load in sandy soil especially at loosest stat. However, vertical load leads to a significant decrease in lateral capacity of piles in homogeneous and inhomogeneous clay layers. It is also found that the influence of vertical loads on the lateral response of pile installed in over-consolidated clay with undrained strength proportional to depth and different OCR in the range of 1.5 to 4.0 is quite different from that with constant undrained strength regardless the adopted OCR value. The 3D finite difference analyses have been, also, carried out to investigate the lateral response of battered piles. The lateral capacity of the battered piles in sandy soils is considerably increased when the value of pile inclination corresponding to the opposite direction of the lateral load increases and when the sand density increases. But in the case of pile inclination corresponding to the same direction of the lateral load, the lateral capacity is slightly increased regardless to the adopted value of batter angle and the sand density. In clayey soil, it was found that the influence of the batter angle on the lateral capacity of piles depends only on the batter angle and not on the clay rigidity. For the case of pile inclination corresponding to the opposite direction of the lateral load, the lateral capacity is moderately increased and for the other case of inclination, the effects are not significant. The influence of both batter angle and vertical load on lateral capacity of battered pile in clayey soils is moderately pronounced.
2

Calcul de la capacité portante des murs en maçonnerie de petits éléments sous charges verticales

Lateb, Mourad 28 March 1995 (has links) (PDF)
Dans cette recherche est développé un modèle de calcul de la capacité portante des murs en maçonnerie de petits éléments sous charges verticales centrées ou excentrées. Le modèle est capable de prendre en compte l'influence des discontinuités mécaniques introduites par les joints horizontaux et verticaux en considérant les caractéristiques mécaniques des blocs et des joints de mortier. La détermination des caractéristiques mécaniques du mortier des joints a également été menée. Les essais sur des éprouvettes découpées dans les joints de mortier après durcissement ont mis en évidence l'influence des phénomènes de succion des blocs sur les caractéristiques mécaniques du mortier. Cette étude a montré également que la détermination de la loi de comportement du mortier à partir .de celle des assemblages et des blocs en utilisant l'approche proposée par PAGE sous-estime la valeur du module d'élasticité initial du mortier. Un dispositif expérimental spécifique a été mis au point pour la détermination des lois excentricité-courbure à effort normal maintenu constant. Ce dispositif permet également de mettre en évidence les modes de rupture observés dans les assemblages ainsi que l'influence du type de mortier sur leur déformabilité. D'une manière générale, on a pu constater une bonne correspondance entre résultats théoriques et expérimentaux en particulier dans le cas où l'on considère la maçonnerie comme un matériau hétérogène.

Page generated in 0.0936 seconds