• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 6
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estabelecimento de parâmetros operacionais, implementação de ensaio de proficiência e avaliação crítica de métodos analíticos empregados em nutrição animal / Establishment of operationally parameters, proficiency test implementation and analytical methods using in animal nutrition critical evaluation

Souza, Gilberto Batista de 05 September 2007 (has links)
Ensaio de Proficiência para Laboratórios de Nutrição Animal (EPLNA) foi implementado com o objetivo de avaliar a variabilidade dos resultados analíticos e o desempenho de laboratórios de nutrição animal instalados no Brasil. A estrutura e a normatização foram planejadas em conformidade com protocolos internacionais para laboratórios analíticos. São reportados e discutidos os resultados referentes a três anos consecutivos. Participaram do ensaio 43 laboratórios provenientes de instituições de pesquisas estaduais, universidades federais e estaduais e empresas privadas. Foram avaliados os resultados referentes aos ensaios de matéria seca, digestibilidade \"in vitro\" da matéria seca, fibra em detergente ácido, fibra em detergente neutro, proteína bruta, extrato etéreo, lignina, cinzas, nitrogênio não protéico, nitrogênio insolúvel em detergente neutro, nitrogênio insolúvel em detergente ácido e os macro e micro nutrientes (Ca, P, Mg, K, S, Cu, Fe, Mn, Zn e Na). O grupo de amostras utilizadas, com diferentes características físicas e químicas, foi constituído de forrageiras, alimentos concentrados e mistura mineral. Para o estudo dos valores designados foram considerados os valores de consenso dos laboratórios participantes, sendo utilizada a estatística clássica ou robusta para a definição destes parâmetros. Baseado no índice z, o projeto estatístico mostrou-se eficaz para identificar o desempenho dos laboratórios, sendo observado o valor 76,9% como índice de desempenho médio dos laboratórios com conceito satisfatório. Os ensaios referentes às determinações de extrato etéreo, lignina e Na apresentaram maior variabilidade interlaboratorial (cvEE = 42,7%, cvLignina = 59,1% e cvNa = 121,2%), considerando todas as amostras estudadas durante os três anos de avaliação. / Proficiency Testing for Animal Nutrition Laboratories was implemented with the objective to evaluate the variability of the analytical results and the performance of Brazilian animal nutrition laboratories. The structure and normalization were planning in accordance with analytical laboratories international protocols. Three years results are reported and discussed. A number of 43 laboratories, from state researches institutes, federal and state universities, and private companies participated of the trial. The performance of the next trial were evaluated: dry material, digestibility \"in vitro\" of the dry material, acid detergent fiber, neutron detergent fiber, crude protein, ether extract, lignin, ash, non protein nitrogen, insoluble nitrogen in neutron detergent, insoluble nitrogen in acid detergent, and the macro and micronutrients (Ca, P, Mg, K, S, Cu, Fe, Mn, Zn, and Na). The studied sample group, with different physical and chemical characteristics, was composed by forage, concentrate feed, and mineral mixing. To study the designated values, the consensus values provided by the laboratories were considered, and classical or robust statistic was used to define these parameters. The statistical design, based on z score, proved to be adequate to identify the laboratories performance, and the 76.9% value was observed as medium score of the laboratories with satisfactory concept. The ether extract, lignin and Na trials presented higher laboratorial varieties (cvEE = 42.7%, cvLignin = 59.1% e cvNa = 121%), considering the evaluated samples during the considered three years.
2

Estabelecimento de parâmetros operacionais, implementação de ensaio de proficiência e avaliação crítica de métodos analíticos empregados em nutrição animal / Establishment of operationally parameters, proficiency test implementation and analytical methods using in animal nutrition critical evaluation

Gilberto Batista de Souza 05 September 2007 (has links)
Ensaio de Proficiência para Laboratórios de Nutrição Animal (EPLNA) foi implementado com o objetivo de avaliar a variabilidade dos resultados analíticos e o desempenho de laboratórios de nutrição animal instalados no Brasil. A estrutura e a normatização foram planejadas em conformidade com protocolos internacionais para laboratórios analíticos. São reportados e discutidos os resultados referentes a três anos consecutivos. Participaram do ensaio 43 laboratórios provenientes de instituições de pesquisas estaduais, universidades federais e estaduais e empresas privadas. Foram avaliados os resultados referentes aos ensaios de matéria seca, digestibilidade \"in vitro\" da matéria seca, fibra em detergente ácido, fibra em detergente neutro, proteína bruta, extrato etéreo, lignina, cinzas, nitrogênio não protéico, nitrogênio insolúvel em detergente neutro, nitrogênio insolúvel em detergente ácido e os macro e micro nutrientes (Ca, P, Mg, K, S, Cu, Fe, Mn, Zn e Na). O grupo de amostras utilizadas, com diferentes características físicas e químicas, foi constituído de forrageiras, alimentos concentrados e mistura mineral. Para o estudo dos valores designados foram considerados os valores de consenso dos laboratórios participantes, sendo utilizada a estatística clássica ou robusta para a definição destes parâmetros. Baseado no índice z, o projeto estatístico mostrou-se eficaz para identificar o desempenho dos laboratórios, sendo observado o valor 76,9% como índice de desempenho médio dos laboratórios com conceito satisfatório. Os ensaios referentes às determinações de extrato etéreo, lignina e Na apresentaram maior variabilidade interlaboratorial (cvEE = 42,7%, cvLignina = 59,1% e cvNa = 121,2%), considerando todas as amostras estudadas durante os três anos de avaliação. / Proficiency Testing for Animal Nutrition Laboratories was implemented with the objective to evaluate the variability of the analytical results and the performance of Brazilian animal nutrition laboratories. The structure and normalization were planning in accordance with analytical laboratories international protocols. Three years results are reported and discussed. A number of 43 laboratories, from state researches institutes, federal and state universities, and private companies participated of the trial. The performance of the next trial were evaluated: dry material, digestibility \"in vitro\" of the dry material, acid detergent fiber, neutron detergent fiber, crude protein, ether extract, lignin, ash, non protein nitrogen, insoluble nitrogen in neutron detergent, insoluble nitrogen in acid detergent, and the macro and micronutrients (Ca, P, Mg, K, S, Cu, Fe, Mn, Zn, and Na). The studied sample group, with different physical and chemical characteristics, was composed by forage, concentrate feed, and mineral mixing. To study the designated values, the consensus values provided by the laboratories were considered, and classical or robust statistic was used to define these parameters. The statistical design, based on z score, proved to be adequate to identify the laboratories performance, and the 76.9% value was observed as medium score of the laboratories with satisfactory concept. The ether extract, lignin and Na trials presented higher laboratorial varieties (cvEE = 42.7%, cvLignin = 59.1% e cvNa = 121%), considering the evaluated samples during the considered three years.
3

[en] METROLOGICAL RELIABILITY OF THE ANTIDOPING LABORATORY OF THE BRAZILIAN JOCKEY CLUB. STUDY CASE: VALIDATION OF ANALYTICAL METHOD FOR DETERMINATION OF CAFFEINE IN URINE OF RACE HORSES / [pt] CONFIABILIDADE METROLÓGICA DO LABORATÓRIO ANTIDOPING DO JOCKEY CLUB BRASILEIRO. ESTUDO DE CASO: VALIDAÇÃO DE MÉTODO ANALÍTICO PARA DETERMINAÇÃO DE CAFEÍNA EM URINA DE CAVALOS DE CORRIDA

INDIA MARIA HILUF DE LIMA 08 October 2004 (has links)
[pt] A presente pesquisa de mestrado relaciona-se ao desenvolvimento e à validação de um método analítico para detecção de substâncias proibidas em matrizes biológicas de cavalos de corrida e seu impacto na confiabilidade metrológica de serviços laboratoriais voltados à atividade turfística visando (i) a especificação de desempenho de um laboratório antidoping capacitado para identificar a presença de substâncias proibidas acordadas pela indústria de carreiras de cavalo; (ii) a adequação às condições brasileiras dos métodos analíticos aplicáveis à determinação antidoping em matrizes biológicas de animais em competição e (iii) a definição de um padrão de excelência harmonizado aos critérios da International Federation of Horseracing Authorities entendidos como instrumentos para a conquista do credenciamento do laboratório antidoping e subseqüente participação em acordos internacionais de reconhecimento mútuo. Para fundamentar o desenvolvimento da pesquisa, o trabalho considerou como estudo de caso o Laboratório Antidoping do Jockey Club Brasileiro (LAD/JCB). Original no seu escopo, o trabalho contribui para ampliar a abrangência da atividade de acreditação laboratorial no Brasil tendo em vista tratar-se de uma nova categoria de laboratório de ensaio ainda não existente na matriz laboratorial credenciada cuja confiabilidade laboratorial foi desenvolvida à luz dos critérios da norma internacional ISO/IEC 17025. No contexto do desenvolvimento são ainda discutidos aspectos relevantes relacionados ao sistema da gestão laboratorial; expressão das incertezas de medição associadas à determinação antidoping em consonância a práticas e procedimentos internacionalmente consensados; capacitação de pessoal técnico especializado; rastreabilidade ao Sistema Internacional de Unidades (SI) e validação e adequação de metodologias analíticas utilizadas em laboratórios antidoping. Atenção particular é direcionada ao Methode Alcalins Sur C- 18, desenvolvido pelo Laboratoire LAB-Contrôle antidopage da França, aplicável a determinação da presença de substâncias dopantes em matrizes biológicas (urina) de cavalos de corrida, utilizado como método fonte para o desenvolvimento de um método alternativo adequado às condições laboratoriais do Laboratório Antidoping do Jockey Club Brasileiro e moldado à detecção de substâncias dopantes mais freqüentes na atividade turfística brasileira. Tendo a cafeína sido estatisticamente identificada a substância mais presente nas análises realizadas pelo Laboratório Antidoping do Jockey Club Brasileiro ao longo de seus sete anos de atuação, o Methode Alcalins Sur C-18 foi adequado e validado para sua determinação analítica. À pesquisa desenvolvida atribuem-se, também, créditos pela introdução de um novo atributo na validação qualitativa da metodologia, denominado valor- limite de determinação, subsidiando a determinação de uma faixa de concentração, para que resultados incorretos (falso-positivos e falso- negativos) não constem de laudos emitidos. Adicionalmente à adequação e validação do método analítico desenvolvido, a pesquisa de mestrado contribuiu não apenas para atribuir visibilidade a uma nova categoria de laboratórios, mas, principalmente, para preparar o Laboratório Antidoping do Jockey Club Brasileiro para demonstrar sua competência técnica como estratégia de conquista de um credenciamento internacionalmente reconhecido. A presente pesquisa de mestrado voltada ao equacionamento de um problema inédito no Brasil de interesse da indústria relacionada à atividade turfística desenvolveu-se no contexto do Convênio FINEP/MCT no. 22.01.0692.00, Referência 1974/01, que aportou recursos do Fundo Setorial Verde Amarelo para direcionar o esforço de pesquisa em metrologia para a solução de dez projetos-piloto de interesse da indústria. No c / [en] This Master s Degree dissertation addresses the development in adjustment and validation and the metrological reliability of laboratory services covering horseracing activities. The work includes (i) the specification of the performance of an antidoping laboratory capable of identifying the presence of forbidden substances, as defined by the horse-racing industry; (ii) the validation of analytical methods applicable in doping tests of biological matrices of competing animals to Brazilian laboratories conditions, and (iii) the definition of a standard of excellence in harmony with the criteria of the International Federation of Horseracing Authorities as the tools utilized for the accreditation of the antidoping laboratory and the subsequent participation in international agreements of mutual recognition. In order to validate the methodology, the Brazilian Jockey Club Antidoping Laboratory (LAD/JCB) was used as a studycase. Original in its scope, this work contributes towards the widening of the accreditation of laboratories in Brazil, considering the fact this new category of testing laboratories is still nonexistent within the Brazilian network of accredited testing laboratories which considers the international standard ISO/IEC 17025 as the basic criteria. With regard to development, some relevant aspects are still being discussed in relation to the laboratory management system: the unreliability of the measurements for the determination of doping, in view of internationally accepted practices and procedures; qualification of specialized technical personnel; traceability of SI (the International Unit System) and the validation and adjustment of analytical methodologies utilized in antidoping laboratories. Special attention is dedicated to Methode Alcalins Sur C- 18, developed by Laboratoire LAB-Contrôle Antidopage in France, applicable to the determination of the presence of doping substances in the biological matrix (urine) of racehorses, used as method source for the development of an alternative method adjusted to the Antidoping Laboratory of the Brazilian Jockey Club conditions and molded to detection of the more frequents doping substances in the brazilian horserancing activities. Having the caffeine been the doping substance statistically identified as the most frequent in the tests carried out by the Brazilian Jockey Club Antidoping Laboratory, along its seven years of services, the Methode Alcalins Sur C-18 was adapted and validated for its analytical determinations. The applied research carried out was also credited with the introduction of a new attribute to the methodology qualitative validation, designated as limit- value for determination, which provides key-information for the determination of a concentration band, in order that incorrect results (false-positive and false- negative) do not appear in the laboratory reports usually issued. Besides the adaptation and validation of the analytical method thus developed, this Master s Degree dissertation contributes not only towards greater visibility of a new category of laboratories, but mainly to the preparation of the Brazilian Jockey Club Antidoping Laboratory to demonstrate its technical capacity as a policy and strategy for becoming in the near future an internationally recognized accredited laboratory. The present M.Sc. Dissertation addresses the metrological reliability of antidoping laboratories, a pioneering issue in Brazil, aiming at the solution of a problem related to the horse-racing industry. It was developed under the financial support of the FINEP/MCT Agreement no. 22.01.0692.00, Reference 1974/01 (Green-Yellow governmental Sectoral Fund) which droved research cooperative efforts in metrology to the solution of ten pilot-projects. In this case specifically, cooperated to the development of the M.Sc. research entitled Metrological reliability of the Antidoping Laboratory of the Brazilian Jockey Club
4

[en] STATISTICAL METHODOLOGY FOR ANALYTICAL METHODS VALIDATION APPLICABLE CHEMISTRY METROLOGY / [pt] METODOLOGIA ESTATÍSTICA PARA VALIDAÇÃO DE MÉTODOS ANALÍTICOS APLICÁVEL À METROLOGIA EM QUÍMICA

SONIA MARIA DE FREITAS 31 October 2003 (has links)
[pt] A metodologia estatística escolhida para validação de métodos analíticos aplicável à metrologia em química é fundamental para assegurar a qualidade, comprovar a eficiência e demonstrar a exatidão dos resultados das medições nas análises químicas. Essa metodologia, desenvolvida em conformidade com o rigor metrológico, resulta num sistema de medições validado, confiável e com incertezas quantificadas. Este trabalho propõe uma metodologia geral para validação de métodos analíticos. A metodologia desenvolvida resultou de uma síntese de métodos parciais descritos na literatura, e inclui uma escolha crítica de técnicas mais adequadas dentro das alternativas existentes. A abordagem proposta combina quatro diferentes aspectos da validação: a modelagem da curva de calibração; o controle da especificidade do método; a comparação da tendência e precisão (repetitividade e precisão intermediária) do método com um método de referência; e a estimação das componentes de incerteza inerentes a todos esses aspectos. Como resultado, além de uma proposta para validação de métodos para uso em análises químicas, obtêm- se a função de calibração inversa e as incertezas expandidas, que permitem obter os resultados analíticos associados aos valores da resposta, com suas respectivas incertezas associadas. Na modelagem geral para obtenção da curva de calibração, empregam-se técnicas estatísticas para avaliação da linearidade e para o cálculo do mínimo valor detectável e do mínimo valor quantificável. A especificidade do método analítico é avaliada pela adição de padrões a um conjunto de amostras representativas e posterior recuperação dos mesmos, com ajuste por mínimos quadrados e testes de hipóteses. Para estudar a tendência e a precisão do método quando comparado a um método de referência, utiliza-se um modelo hierárquico de quatro níveis e a aproximação de Satterthwaite para determinação do número de graus de liberdade associados aos componentes de variância. As técnicas estatísticas utilizadas são ilustradas passo a passo por exemplos numéricos. / [en] The use of statistical methodology for analytical methods validation is vital to assure that measurements have the quality level required by the goal to be attained. This thesis describes a statistical modelling approach for combining four different aspects of validation: checking the linearity of the calibration curve and compute the detection and the quantification limits; controlling the specificity of the analytical method; estimating the accuracy (trueness and precision) of the alternative method, for comparison with a reference method. The general approach is a synthesis of several partial techniques found in the literature, according to a choice of the most appropriate techniques in each case. For determination of the response function, statistical techniques are used for assessing the fitness of the regression model and for determination of the detection limit and the quantification limit. Method specificity is evaluated by adjusting a straight line between added and recovered concentrations via least squares regression and hypotheses tests on the slope and intercept. To compare a method B with a reference method A, the precision and accuracy of method B are estimated. A 4-factor nested design is employed for this purpose. The calculation of different variance estimates from the experimental data is carried out by ANOVA. The Satterthwaite approximation is used to determine the number of degrees of freedom associated with the variance components. The application of the methodology is thoroughly illustrated with step-by-step examples.
5

[en] METROLOGICAL EVALUATION OF SUNSCREENS BY LDI-TOF MASS SPECTROMETRY / [pt] AVALIAÇÃO METROLÓGICA DE FILTROS SOLARES POR ESPECTROMETRIA DE MASSA LDI-TOF

JORGE MARCIAL AGUERO ANDRADE 01 November 2018 (has links)
[pt] Diversos trabalhos de pesquisa constatam as evidentes correlações entre a exposição excessiva à radiação solar e a incidência de câncer de pele, de catarata e de envelhecimento precoce da pele. O mercado de cosméticos destinados à proteção solar encontra-se em franca expansão; diversos países adotam legislações específicas para esses produtos. No Brasil eles são regulados pela Agência Nacional de Vigilância Sanitária (ANVISA). Porém, não existem métodos oficiais de análise química para determinar filtros solares em cosméticos. No presente trabalho foi desenvolvido um procedimento de análise qualitativa de cosméticos comerciais com filtros solares por espectrometria de massa LDI-TOF (Laser Desorption Ionization - Time-of-Flight). A técnica LDI utiliza um feixe de luz laser monocromático, Lambda = 337nm, como sonda para excitar, dessorver e ionizar o analito. Embora o espectro da radiação solar seja contínuo, o comprimento de onda utilizado em LDI se situa bem próximo do valor médio da faixa de radiação que compreende UVA e UVB, o que torna a técnica LDI potencialmente apropriada para excitar moléculas das substâncias ativas similarmente aos raios solares. Por tais características, é razoável esperar que LDI seja seletiva para detectar filtros solar presentes nas composições dos cosméticos. Paralelamente, foi utilizada também a espectrometria de massa (252)Cf-PDMS (Plasma Desorption Mass Spectrometry), que utiliza os fragmentos de fissão do nuclídeo radioativo califórnio 252 no lugar do laser. Foram obtidos espectros de massa de íons positivos e negativos de 8 cosméticos comerciais por ambas as técnicas, bem como espectros PDMS das substâncias ativas permitidas pela ANVISA. As massas observadas nos espectros de massa LDI dos produtos selecionados foram comparadas com: i) as massas moleculares de todas as substâncias ativas permitidas; ii) as massas observadas nos espectros PDMS das substâncias padrões permitidas e dos cosméticos comerciais; iii) as massas moleculares dos filtros solares indicados nos rótulos. A seletividade da técnica LDI para identificar filtros solares em cosméticos foi demonstrada pelos espectros de massa de íons positivos e negativos das oito amostras analisadas. / [en] Several studies of research note the obvious correlation between excessive exposure to sunlight, and the incidence of skin cancer, cataracts and premature aging of the skin. The market for cosmetics for sun protection is in the booming; various countries adopt laws specific to these products. In Brazil they are regulated by the National Sanitary Surveillance Agency (ANVISA). However, there are no official methods of chemical analysis to determine solar filters in cosmetics. In this work was developed a procedure for qualitative analysis of commercial cosmetics with solar filters by mass spectrometry LDI-TOF (Laser Desorption Ionization - Time-of-Flight). LDI technique uses a beam of monochromatic laser light, Lambda = 337 nm, as a probe to excite, desorbs and ionize the analyte. Although the spectrum of solar radiation is continuous, the wavelength used in LDI is well on the average range of radiation that includes UVA and UVB, which makes technical LDI potentially suitable to excite molecules of active substances similarly to lightning Sun. For such characteristics, it is reasonable to expect that LDI be selective to detect solar filters presents on cosmetics products. In parallel, was also used mass spectrometry (252)Cf-PDMS (Plasma Desorption Mass Spectrometry), which uses fragments of the fission of radioactive nuclide californium 252 instead of laser. Mass spectra were obtained from positive and negative ions, eight commercial cosmetics by both techniques, and PDMS spectra of active substances allowed by ANVISA. Masses observed on LDI mass spectra from selected products were compared with: i) molecular masses of all active substances allowed; ii) masses observed on PDMS mass spectra from standards allowed and commercial cosmetics; iii) molecular masses of sunscreens in its labels. The selectivity of the LDI technique to identify solar filters in cosmetics was demonstrated by mass spectra of positive and negative ions of the eight samples.
6

[en] ANALYSIS OF THE UNCERTAINTIES OF THE QUANTITATIVE PHASE ANALYSIS BY X-RAY POWDER DIFFRACTION BASED ON THE RIETVELD METHOD / [pt] ANÁLISE DAS INCERTEZAS DA QUANTIFICAÇÃO DE FASE PELO MÉTODO DE RIETVELD EM ANÁLISE DE PÓ POR DIFRAÇÃO DE RAIOS X

TEREZINHA FERREIRA DE OLIVEIRA 25 April 2005 (has links)
[pt] A análise de sistemas de medição consiste do exame da adequação do sistema quanto ao operador, ao instrumento e a outras fontes de variação, bem como da comparação da variância do erro de medição com a variância natural do processo. Nesse aspecto, esta pesquisa teve por objetivo a análise das incertezas da quantificação de fase pelo método de Rietveld em análise de pó. Os efeitos de vários fatores na quantificação de fase foram avaliados utilizando técnicas estatísticas de planejamento experimental e de análise multivariada, com a utilização de materiais de alto nível de rastreabilidade na realização dos experimentos, no Laboratório de difração de raios X do Departamento de Ciências de Materiais e Metalurgia da PUC-Rio. Através da determinação do construto de variação do processo, constatou-se que a quantificação das fases analisadas sofre influência das condições de medição de forma diferenciada de material para material, impossibilitando a obtenção de uma fórmula geral para cálculo dos erros de quantificação, embora os erros possam ser determinados por uma análise de repetitividade e reprodutibilidade apropriadamente conduzida. / [en] The analysis of measurement systems is done by the examination of the adequacy of the system according to the operator, the instrument and other sources of variability, as well as by the comparison of the measurement error variance with the natural process variance. This research consisted in the evaluation of the uncertainties of phase quantification in powder analysis by the Rietveld method. The evaluation of the effects of several factors on the phase quantification was performed using statistical techniques of design of experiments and of multivariate analysis, with the use of materials of high level of traceability for the conduction of the experiments, in the Laboratory of X-ray Diffraction of the Pontifícia Universidade Católica do Rio de Janeiro. Through the determination of the variational structure of the process it was verified that the analyzed phases suffer influence of the measurement conditions in a differentiated way, which prevents the obtention of a general formula for calculation of the quantification error, although the errors can be determined by a repeatability and reproducibility analysis properly conducted.

Page generated in 0.0908 seconds