• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 108
  • 5
  • 5
  • 5
  • 5
  • 5
  • 1
  • Tagged with
  • 110
  • 55
  • 33
  • 30
  • 30
  • 27
  • 24
  • 23
  • 18
  • 16
  • 15
  • 14
  • 14
  • 13
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Estudo do comportamento mecanico de um solo artificialmente cimentado / Study of the mechanical behavior of an arti ficially cemented soil

Prietto, Pedro Domingos Marques January 1996 (has links)
A melhoria das características mecânicas de solos naturais constitui uma técnica de crescente utilização na engenharia geotécnica, em especial na execução de fundações sobre solos moles . Algumas soluções passam pela utilização de materiais geotécnicos cimentados , tais como o solo-cimento, o solo-cal, etc. Estas aplicações, no entanto, requerem o conhecimento das características de deformação e de resistência dos materiais utilizados. No presente trabalho, a partir de um programa experimental que incluiu ensaios de resistência à compressão simples, ensaios triaxiais drenados (CID) com medição interna de deformações axiais, e microscopia eletrõnica de varredura, um solo arenoso artificialmente cimentado teve seu comportamento mecânico investigado, frente à variação do grau de cimentação (0, 1, 3 e 5% de adição de cimento Portland) e da tensão efetiva média inicial (p;' = 20, 60 e Os resultados mostraram que o comportamento do solo cimentado foi i nfluenciado por ambas as variáveis investigadas . No entanto, para a faixa de tensões efetivas estudada, o comportamento foi basicamente comandado pelo grau de cimentação. Visando a aplicação do material investigado em. projetos geotécnicos, uma abordagem é proposta para a determinação da resistência ao cisalhamento drenada e do módulo de deformação estática. A inclusão na análise de outros resultados encontrados na literatura permitiram ampliar alguns aspectos desta abordagem. / The improvement of natural soils characteristics is a largely used process in geotechnical engineeringf specially in foundation designs on soft grounds. Sometimesf cemented materialsf l ike soilcement and soil-lime admixtures f are employed. These applications require the knowledge of the strain and strength characteristics of materials . In this work an experimental programme was carried out to investigate the mechanical behavior of an artificially cemented sandy soilf which includes unconfined compression tests f drained triaxial compression tests (CID) with local measurements of axial strains f and scanning electron microscopy analysis. The influence of cementation level (O f l f 3 and 5% Portland cement content) and ini tial mean effecti ve stress ( p;' = 20 f 60 and 100 kN/m2 ) were evaluated . Test results have demonstrated t hat the cemented soil behavior was significantly affected by bothf cementation level and i nitial mean effective stress . However f for the range of eff ect ive stresses investigated herein f soil behavi or was mainly controlled by cementation level . Finally f to allow the application of t he investigated material into geotechnical worksf an approach is proposed to determinate the drained shear strength and the static deformati on moduli of the cemented soil. Data from other investigation programmes were incorporated to the present study to allow generalization of some aspects of the proposed approach.
22

Aplicação do modelo dente de serra em solos estruturados.

Reis, Fernanda Rocha dos January 2005 (has links)
Programa de Pós Graduação em Engenharia Civil. Departamento de Engenharia Civil, Escola de Minas, Universidade Federal de Ouro Preto. / Submitted by giuliana silveira (giulianagphoto@gmail.com) on 2016-01-22T17:30:47Z No. of bitstreams: 1 DISSERTAÇÃO_AplicaçãoModeloDente.pdf: 5220492 bytes, checksum: 5d29b54b1667f04bac8ff1137605c05c (MD5) / Approved for entry into archive by Oliveira Flávia (flavia@sisbin.ufop.br) on 2016-01-25T14:59:46Z (GMT) No. of bitstreams: 1 DISSERTAÇÃO_AplicaçãoModeloDente.pdf: 5220492 bytes, checksum: 5d29b54b1667f04bac8ff1137605c05c (MD5) / Made available in DSpace on 2016-01-26T15:29:56Z (GMT). No. of bitstreams: 1 DISSERTAÇÃO_AplicaçãoModeloDente.pdf: 5220492 bytes, checksum: 5d29b54b1667f04bac8ff1137605c05c (MD5) Previous issue date: 2005 / Estudos de estabilidade de encostas naturais, projetos de cortes e fundações, são normalmente desenvolvidos com base no critério de resistência de Mohr-Coulomb. Este trabalho procurou apresentar uma nova proposta paramétrica, tomando-se com base, o modelo Dente de Serra. Face a aplicação direta das leituras dos ensaios de cisalhamento direto ao modelo Dente de Serra, estes foram realizados neste estudo. Para avaliação dos parâmetros do modelo Dente de Serra, foram utilizados solos puramente arenosos, uniformes, caracterizados como areia grossa e média/fina. Estes estudos propiciaram interpretações mais detalhadas do comportamento ao cisalhamento das areias, com foco macroscópico e ao nível de contato. Para aplicação do modelo Dente de Serra em solos estruturados, foi apresentado um modelo expandido. Com a aplicação do modelo expandido, foi possível determinar a coesão verdadeira. Para avaliar o comportamento da coesão verdadeira face ao grau de cimentação, foram confeccionadas amostras de areia grossa cimentadas com teores de 3, 6, 9, 12 e 15%. A sensibilidade ao nível de tensão foi estudada através do uso de quatro níveis distintos de tensão. Para confiabilidade dos resultados, cada ensaio foi realizado três vezes. Estes estudos demonstraram que a coesão verdadeira e os parâmetros friccionais são sensíveis ao nível de tensão e a cimentação. O modelo expandido foi então aplicado a um solo natural intemperizado. Os resultados mostraram que a coesão verdadeira comportou-se de forma muito sensível ao nível de tensão, sendo a eficiência da cimentação muito baixa para baixos níveis de tensão. Do ponto de vista prático profissional, os resultados mostraram a necessidade de adequação paramétrica dos estudos de estabilidade e capacidade de suporte em materiais estruturados. _______________________________________________________________________ / ABSTRACT : Stability analysis of natural slope, excavation and foundation design are usually made considering the Mohr-Coulomb strength criteria. This work intends to show a new parametric proposal, taking into account the conventional saw model. Due to direct application of the results of the direct shear tests on the saw model, this test was chosen for this work. To quantify the model parameters, a uniform sandy soil, described as thin to coarse sand, was used in laboratory tests. This procedure result in studies with much more details about the sand shear behavior, with focus on macroscopic and also grain contact level. An expansion of the saw model has to be formulated in order to make it suitable for studied structured cemented soil. In this way, the true cohesion parameter of soil could be determined. To analyze the true cohesion behavior by taking in to consideration the level of cementation, samples of cemented coarse sand with 3, 6, 9, 12 e 15% on cement content were tested. The sensitivity of the stress level was evaluated trough the use of four distinct stress level. Testes were run three times so as to assure the reliability of the results. The results have shown that the true cohesion and the friccional parameters are sensitive to the normal stress level and to the cement content. Finally, the expanded saw model was applied in a structured natural soil. The results have shown that the cohesion parameter was very sensitive to the normal stress level and the cement efficiency was poor in low normal stress levels. Concerning a practical point of view, this research have shown the need of suitable parametric studies for slope stability analysis and bearing support design when dealing with structured materials.
23

Cimentação adesiva de materiais CAD/CAM resina-cerâmica

Lise, Diogo Pedrollo January 2015 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2015. / Made available in DSpace on 2016-10-19T13:18:54Z (GMT). No. of bitstreams: 1 338968.pdf: 26388567 bytes, checksum: 2069b93e85f123b8ac3c78a879aef322 (MD5) Previous issue date: 2015 / Objetivos: Avaliar o efeito de diferentes tratamentos de superfície e do tempo de armazenamento na resistência de união adesiva à microtração (µTBS) de blocos CAD/CAM do tipo resina-cerâmica. Materiais e Métodos: Dois tipos de blocos CAD/CAM resina-cerâmica (Cerasmart, GC e Enamic, Vita Zahnfabrik) foram seccionados em fatias com 4 mm de espessura, distribuídos em seis grupos e submetidos aos seguintes tratamentos de superfície: Grupo 1: sem tratamento; Grupo 2: jateamento com óxido de alumínio 27 µm + silano; Grupo 3: condicionamento com ácido hidrofluorídrico 5% por 60 seg + silano; Grupo4: condicionamento com ácido fosfórico 37% por 60 seg + silano; Grupo 5: jateamento; Grupo 6: jateamento + silano. Pares de fatias do mesmo material e grupo foram cimentadas umas às outras (n=3 espécimes sanduíches/grupo) utilizando um cimento resinoso dual autoadesivo para os grupos 1 ao 5, e uma resina fluida fotopolimerizável para o grupo 6. Após respectivamente três semanas e 6 meses de armazenamento em cloramina 0,5% à 37oC, os espécimes sanduíches foram seccionados em micro espécimes retangulares, desgastados na interface adesiva (forma de ampulheta) e submetidos ao teste de µTBS. Os dados foram estatisticamente analisados por um modelo linear de efeitos mistos considerando como fatores o tipo de material, o tratamento de superfície e o tempo de armazenamento, assim como suas interações de primeiro grau(p=0,05). Resultados: Independente do tratamento de superfície e tempo de armazenamento, os dois materiais resina-cerâmica apresentaram valores deµTBS sem diferença estatística. Após 3 semanas, todos os grupos obtiveram valores similares. Depois de 6 meses, os valores de resistência adesiva foram mantidos quando foi realizado o JAT com óxido de alumínio (Grupo 263) ou o condicionamento com HF (Grupo 5), ambos seguidos por silanização. O JAT seguido de silanização e o uso de uma resina fluida como agente cimentante também manteve a µTBS. A ausência de tratamento superficial (Grupo 1), o JAT isolado (Grupo 2) e o condicionamento com H3PO4 seguido de silanização (Grupo 6) resultaram em uma diminuição da µTBS. Conclusões: ambos materiais do tipo resina-cerâmica demonstraram µTBS similar, independente do tratamento de superfície. A criação de uma superfície microrretentiva através do JAT com óxido de alumínio ou condicionamento com HF, seguido de silanização, é necessária para manutenção resistência de união adesiva após 6 meses.<br> / Objectives: To evaluate the effect of different surface treatments on the bond strength to resin-ceramic CAD/CAM blocks after six months. Materials and Methods: Two types of resin-ceramic CAD/CAM blocks (Cerasmart, GC; Enamic, Vita Zahnfabrik) were cut in slabs of 4-mm thickness, divided into six groups and subjected to the following surface treatments: Group 1: No treatment; Group 2: Sandblasting (SB); Group 3: SB + Silane; Group 4: SB + Silane; Group 5: 5% Hydrofluoric acid (HF) etching + Silane; Group 6: 37% Phosphoric acid (H3PO4) etching + Silane. Sections of the same group were luted together (n=3 sandwich specimens/group) using a dual-cure self-adhesive cement for all groups, except for Group 4 that were luted using a flowable light-curing composite. After three weeks of storage in 0.5% chloramine at 37oC, the sandwich specimens were sectioned in rectangular micro-specimens and trimmed to an hourglass shape. Part of the specimens was subjected to a micro-tensile bond strength (µTBS) test and the other half was tested after 6 months of storage. Data were statistically analyzed with a linear mixed effects model for the factors surface treatment, material type and storage period, together with their first-degree interactions (p=0.05). Results: The lowest bond strengths were obtained in the absence of any surface treatment (Group 1), while the highest bond strengths were obtained when the surface was roughened by either SB or HF etching, this in combination with chemical adhesion through silanization. Loss in bond strength was observed after six months when either surface roughening or silanization, or both, were omitted. Conclusions: Both resin-ceramic CAD/CAM blocks appeared equally bonding-receptive regardless of the surface treatment. Creating a microretentive surface by either SB or HF etching, followed by chemical adhesion using a silane coupling agent is mandatory to maintain the bond strength after six months.
24

Análise da espessura da película de cimentos de ionômero vítreo e fosfato de zinco, empregados na cimentação de coroas totais metálicas, preparadas in vivo

Pavanelli, Carlos Augusto [UNESP] 18 June 1997 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:22:18Z (GMT). No. of bitstreams: 0 Previous issue date: 1997-06-18. Added 1 bitstream(s) on 2015-12-10T14:28:21Z : No. of bitstreams: 1 000125620.pdf: 2996163 bytes, checksum: f515bf3dab8364f60e260ee782ec47e0 (MD5) / A presente pesquisa consistiu em analisar a espessura da película de cimentos de ionômero vítreo (Vidrion C, SS WHITE, Brasil; Ketac Cem, ESPE, Alemanha) in vivo, comparando os resultados com um cimento de fosfato de zinco (Lee Smith, TELEDYNE WATER PIK, USA), na cimentação de coroas totais metálicas. Foram utilizados 21 dentes íntegros, com exodontia indicada para fins ortodônticos, que foram preparados para receber coroa total metálica. O processamento laboratorial das fundições, foi feito em laboratório comercial, de forma padronizada. Todas as coroas foram aliviadas internamente, através da prévia aplicação de cinco camadas de verniz espaçador sobre os troquéis. As cimentações, foram feitas, inicialmente sob pressão digital, seguida por pressão de assentamento pela oclusão, com um mordente de madeira de laranjeira, interposto entre a coroa e a arcada antagonista. Os resultados mostraram, pelo teste estatístico ANOVA, valores semelhantes para os três cimentos, ao nível de 1%. Entretanto, quando a espessura da película do cimento foi analisada sob as variáveis cimento e posição de mensuração na superfície do dente preparado, encontrou-se que nas paredes axiais, havia diferença entre o cimento Lee Smith e o Vidrion C, onde os valores para o Vidrion foram significativamente menores. Nas demais posições analisadas, não houve diferença significante ao nível de 5%. Quando esses mesmos valores foram apreciados através de representação gráfica (diagrama, do tipo BOX-PLOT), do cimento em função da posição de mensuração, observou-se, no caso do cimento de fosfato de zinco, uma tendência de distribuição dos valores, por toda a faixa compreendida entre o valor máximo e o valor mínimo da película. Os cimentos de ionômero vítreo, tenderam a concentrar seus valores, em relação à faixa de distribuição, a níveis mais baixos que o cimento de fosfato de zinco. O Vidrion C, em particular, foi o que... / This study evaluated the film thicknesses of two GIC cements (Vidrion C, SS WHITE, Brazil; Ketac Cem, ESPE, Germany) and one zinc phosphate cement (Lee Smith, TELEDYNE, USA), used for final cementation of complete metal crowns. Twenty-one teeth scheduled for extraction due to orthodontic treatment were prepared for complete metal crowns. Dies were relieved with 5 layers of die varnish spacer. The crowns were manufactured by a commercial laboratory (with standardized procedures as much as possible) and cemented first with finger pressure and later by occlusion pressure using orange wood sticks. Results submitted to an ANOVA test showed that all cements had a similar behavior showing no significant statistical differences (p<0.01). A film thickness analysis of 7 selected preparations sites, showed that only axial positions, presented differences between Lee Smith and Vidrion C cements, the latter presenting lower significant values. For other positions studied, the three cements showed no significant statistical differences (p<0.05). Technical exploratory analysis of data by a BOX PLOT graphic showed for the ZPC a broad film thickness value distributions (from the highest to the lowest values) related to type of cement and measurement values. For glass ionomer cement the graphic presented values concentrating at lower levels than zinc phosphate cement. This was still more evident for the Vidrion C cement
25

Efeito de nanofilmes depositados a plasma na resistência de união de um cimento resinoso a uma cerâmica à base de zircônia

Figueiredo, Viviane Maria Gonçalves de [UNESP] 07 October 2014 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:24:30Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-10-07. Added 1 bitstream(s) on 2015-09-17T15:47:44Z : No. of bitstreams: 1 000843821.pdf: 3702436 bytes, checksum: d6873085a79717fb329e4d79616a41ad (MD5) / Esta pesquisa objetivou avaliar o efeito de diferentes nanofilmes depositados a plasma na resistência de união entre cimento resinoso e cerâmica à base de zircônia. 120 blocos/espécimes (15,2 x 12,5 x 1,7 mm) e 18 discos (11,0 x 1,4 mm) de zircônia (Y-TZP) (VITA In-Ceram Zirconia, Vita Zahnfabrik, Alemanha) receberam diferentes tratamentos de superfície (n = 20 para os blocos) (n = 3 para discos): zircônia sem tratamento (Zrpolida), jateamento de alumina revestida por sílica (30 μm) (Zrjat#), nanofilme à base de sílica (ZrSiO2), jateamento de alumina (45 μm) + nanofilme à base de sílica (Zrjat+SiO2), e nanofilme à base de fluoreto (ZrF) e jateamento de alumina (45 μm) + nanofilme à base de fluoreto (Zrjat+F). Os nanofilmes foram depositados por meio da técnica a plasma PECVD. As superfícies cerâmicas foram caracterizadas pela morfologia (MEV e MFA), química (XPS) e molhabilidade (ângulo de contacto), realizada nos discos. O agente de união silano foi aplicado em cada superfície e um cilindro de cimento resinoso foi construído sobre os espécimes tratados. Metade dos espécimes de cada grupo (n = 10) foram submetidos a 6.000 ciclos térmicos. A resistência de união foi avaliada pelo teste de cisalhamento e análise fractográfica pelo estereomicroscópico, MEV e EDS. Para análise estatística utilizou-se ANOVA 1-Fator e o teste de Tukey, para presença e ausência de envelhecimento (p = 0,05). A zircônia apresentou-se mais hidrofílica após a deposição dos nanofilmes. Ligações químicas entre Si-O foram encontradas em ZrSiO2; ZrF promove um processo de fluoração na superfície da cerâmica Y-TZP, convertendo-a em oxifluoreto de zircônio. Os valores de resistência de união iniciais obtidos pelos tratamentos de superfície a plasma não superaram os valores de união da silicatização. Após o envelhecimento, todas as amostras do grupo ZrSiO2(TC) sofreram falhas pré-teste. OS valores de resistência de.... / This study aimed to evaluated the effects of differents plasma nanofilms on the bond strength between resin cement and zirconia ceramic. 120 blocks / specimens (15.2 x 12.5 x 1.7 mm) and 18 discs (11.0 x 1.4 mm) of zirconia (Y-TZP) (VITA In-Ceram Zirconia, Vita Zahnfabrik, Germany) received differents treatments surface (n = 20 for the blocks) (n = 3 for discs): untreated zirconia (Zrpolida), silica-coated (30 μm) (Zrjat#), silica nanofilm (ZrSiO2), sandblasted by air-borne particle abrasion with aluminum oxide particles (45 μm) + silica nanofilm (Zrjat+SiO2) and fluoride nanofilm (ZrF) and sandblasted by air-borne particle abrasion with aluminum oxide particles (45 μm) + fluoride nanofilm (Zrjat+F). The nanofilms were deposited by PECVD technique of the plasma. The ceramic surfaces were characterized by morphology (SEM and AFM), chemical (XPS) and wettability (Contact angle), that was performed on discs. The silane agent was applied to each surface treatment and a cylinder of resin cement was built on the specimens. Half of the samples of each group (n = 10) were subjected to 6.000 thermalcycles. The bond strength was evaluated by shear test and fractographic analysis by stereoscopic, SEM and EDS. Statistical analysis was performed using one-way ANOVA and Tukey's test for the presence and absence non-aged (p = 0.05). Zirconia presented more hydrophilic after nanofilms deposition. Chemical bonds between Si-O were found in ZrSiO2; ZrF promotes a process of fluorination on the Y-TZP surface, promoting the conversion of zirconia in zirconium oxyfluoride. The initial values of bond strength obtained by plasma treatment did not exceed the bond values of the silica-coated. After aging, all samples of the group ZrSiO2 (TC) falied. The values of bond strength of ZrF (TC) (3.8 MPa) were lower than Zrjat# (TC) (15.4 MPa) and Zrpolida (TC) (6.3 MPa). The silica nanofilm showing detachment after shearing. Adhesive failures were predominant among the...
26

Avaliação clínica de restaurações classe v restauradas com a técnica direta e semidireta

Rodrigues, Patrícia Silva Hamester January 2013 (has links)
Made available in DSpace on 2015-06-16T02:06:47Z (GMT). No. of bitstreams: 1 000468076-Texto+Completo-0.pdf: 1121444 bytes, checksum: 65fc7c05be36d73bf2d8b7f5853d6a61 (MD5) Previous issue date: 2013 / Objective: The objective of this study was to evaluate in 6 months Class V restorations clinically with composite resin ( Glacier ) and glass ionomer cement ( Riva selfcure ) with the direct technique and restorations semidirect technique, cemented with self-adhesive resin cement ( SeT ) and total etching cement ( RelyX ARC ).Methods: One hundred and twenty restorations were performed by a single operator in 30 patients. Each patient received a composite resin restoration ( RGLA ), glass ionomer cement ( RVA ), ceromer cemented with RelyX ARC ( RARC ), and cemented with SeT (RSET ). After 6 months, the evaluation was performed using the USPHS criteria for the presence of restoration, marginal integrity, color and presence of secondary caries .Results: The results were obtained through statistical analysis of generalized linear mixed model and showed that only the restorations cemented with SeT were statistical difference, with significant loss of restorations. No patient had secondary caries after 6 months of evaluation. The marginal integrity and color were not significantly different between groups .Conclusion: We conclude that restorations cement with self-adhesive SeT failed. Thus the direct restorations had a better behavior than the semidirect restorations. However semidirects restorations cemented with Adper Single Bond 2 + RelyX ARC and total etching presented along with the RVA group the highest predictive average. / Objetivo: O Objetivo deste trabalho foi avaliar clinicamente no período de 6 meses restaurações classe V em resina composta (Glacier) e cimento de ionômero de vidro (Riva selfcure) pela técnica direta, e restaurações com cerômero pela técnica semidireta cimentadas com cimento resinoso autoadesivo (SeT) e com condicionamento total (RelyX ARC).Material e método: Cento e vinte restaurações foram realizadas por um único operador em 30 pacientes. Cada paciente recebeu uma restauração de resina composta (RGLA), Cimento de ionômero de vidro (RVA), cerômero cimentada com RelyX ARC (RARC), e cerômero cimentada com SeT (RSET). Após 6 meses as avaliações foram realizadas através dos critérios do USPHS modificado quanto à presença da restauração, integridade marginal, descoloração marginal e presença de cárie secundária. Resultados: Os resultados foram obtidos através da análise estatística de modelo linear misto generalizado e mostraram que somente as restaurações de cerômero cimentadas com SeT apresentaram diferença estatística, com perda significativa das restaurações. Nenhum paciente apresentou cárie secundária após os 6 meses de avaliação. A integridade marginal e descoloração marginal não apresentaram diferença estatística entre os grupos. Cconclusão: Concluímos que as restaurações realizadas com cimento autoadesivo SeT falharam. Desta forma as restaurações diretas tiveram um comportamento melhor que as restaurações semidiretas. Todavia as restaurações semidiretas cimentadas com Adper Single Bond 2 + RelyX ARC e condicionamento ácido total apresentaram junto com o grupo RVA a maior média preditiva.
27

Análise da espessura da película de cimentos de ionômero vítreo e fosfato de zinco, empregados na cimentação de coroas totais metálicas, preparadas "in vivo" /

Pavanelli, Carlos Augusto. January 1997 (has links)
Orientador: José Eduardo Junho de Araújo / Banca: Eulália Maria Martins Silva / Banca: Marcos Yasunóri Maekawa / Resumo: A presente pesquisa consistiu em analisar a espessura da película de cimentos de ionômero vítreo (Vidrion C, SS WHITE, Brasil; Ketac Cem, ESPE, Alemanha) in vivo, comparando os resultados com um cimento de fosfato de zinco (Lee Smith, TELEDYNE WATER PIK, USA), na cimentação de coroas totais metálicas. Foram utilizados 21 dentes íntegros, com exodontia indicada para fins ortodônticos, que foram preparados para receber coroa total metálica. O processamento laboratorial das fundições, foi feito em laboratório comercial, de forma padronizada. Todas as coroas foram aliviadas internamente, através da prévia aplicação de cinco camadas de verniz espaçador sobre os troquéis. As cimentações, foram feitas, inicialmente sob pressão digital, seguida por pressão de assentamento pela oclusão, com um mordente de madeira de laranjeira, interposto entre a coroa e a arcada antagonista. Os resultados mostraram, pelo teste estatístico ANOVA, valores semelhantes para os três cimentos, ao nível de 1%. Entretanto, quando a espessura da película do cimento foi analisada sob as variáveis cimento e posição de mensuração na superfície do dente preparado, encontrou-se que nas paredes axiais, havia diferença entre o cimento Lee Smith e o Vidrion C, onde os valores para o Vidrion foram significativamente menores. Nas demais posições analisadas, não houve diferença significante ao nível de 5%. Quando esses mesmos valores foram apreciados através de representação gráfica (diagrama, do tipo BOX-PLOT), do cimento em função da posição de mensuração, observou-se, no caso do cimento de fosfato de zinco, uma tendência de distribuição dos valores, por toda a faixa compreendida entre o valor máximo e o valor mínimo da película. Os cimentos de ionômero vítreo, tenderam a concentrar seus valores, em relação à faixa de distribuição, a níveis mais baixos que o cimento de fosfato de zinco. O Vidrion C, em particular, foi o que... / Abstract: This study evaluated the film thicknesses of two GIC cements (Vidrion C, SS WHITE, Brazil; Ketac Cem, ESPE, Germany) and one zinc phosphate cement (Lee Smith, TELEDYNE, USA), used for final cementation of complete metal crowns. Twenty-one teeth scheduled for extraction due to orthodontic treatment were prepared for complete metal crowns. Dies were relieved with 5 layers of die varnish spacer. The crowns were manufactured by a commercial laboratory (with standardized procedures as much as possible) and cemented first with finger pressure and later by occlusion pressure using orange wood sticks. Results submitted to an ANOVA test showed that all cements had a similar behavior showing no significant statistical differences (p<0.01). A film thickness analysis of 7 selected preparations sites, showed that only axial positions, presented differences between Lee Smith and Vidrion C cements, the latter presenting lower significant values. For other positions studied, the three cements showed no significant statistical differences (p<0.05). Technical exploratory analysis of data by a BOX PLOT graphic showed for the ZPC a broad film thickness value distributions (from the highest to the lowest values) related to type of cement and measurement values. For glass ionomer cement the graphic presented values concentrating at lower levels than zinc phosphate cement. This was still more evident for the Vidrion C cement / Mestre
28

Avaliação clínica de restaurações indiretas em resina composta cimentadas com material resinoso convencional e autoadesivo

Marcondes, Maurem January 2014 (has links)
Made available in DSpace on 2014-06-04T17:46:30Z (GMT). No. of bitstreams: 1 000458471-Texto+Completo-0.pdf: 1434696 bytes, checksum: 1b82056bbee62d1935b0803e571f0c64 (MD5) Previous issue date: 2014 / The aim of this study was to clinically evaluate the performance of indirect composite resin restorations cemented with conventional and self-adhesive resin cement, during a 12-month period. Twenty-four composite resin restorations were performed through indirect technique and cemented with two resin cements: a conventional (RelyX ARC) and a self-adhesive (RelyX U100). Two independent evaluators analyzed the restorations using the criteria of the USPHS (United States Public Health Service) modified after two weeks, six months and 12 months. For the analysis of data from USPHS, between the cements at the same time, it was used the Wilcoxon statistical test and for evaluation at different times, it was used the Mann-Whiney test, at significance level of 5 %. The Fisher exact test was used to assess the occurrence of absolute failures. No statistically significant differences were found between groups in the same period and between groups at different times, one statistical difference was found only for the criteria color match. We conclude that indirect composite resin restorations cemented with self-adhesive resin cement showed a similar performance of restorations cemented with conventional resin cement after a year of analysis. / O objetivo deste estudo foi avaliar clinicamente o desempenho de restaurações indiretas de resina composta cimentadas com cimento resinoso convencional e autoadesivo no período de 12 meses. Foram realizadas 24 restaurações em resina composta (Filtek Supreme XT), executadas pela técnica indireta e cimentadas com dois cimentos resinosos: um convencional (RelyX ARC) e um autoadesivo (RelyX U100). Dois avaliadores independentes analisaram as restaurações através dos critérios do USPHS (United States Public Health Service) modificado após duas semanas, seis meses e 12 meses. Para a análise dos dados do USPHS, entre os cimentos no mesmo tempo, foi utilizado o teste estatístico de Wilcoxon e, para avaliação nos diferentes tempos, o Mann-Whiney ao nível de significância de 5%. O teste exato de Fisher foi usado para avaliar a ocorrência de falhas absolutas. Não foram encontradas diferenças estatisticamente significativas entre os grupos no mesmo período e entre os grupos nos diferentes tempos, havendo diferença estatística apenas para o critério combinação de cor. Pode-se concluir que restaurações de resina composta indireta cimentadas com cimento resinoso autoadesivo tiveram um desempenho similar às cimentadas com cimento resinoso convencional após um ano de avaliação.
29

Influência do alívio, tipo de cimento e anatomia radicular na remoção de núcleos metálicos com ultrassom sob diferentes condições

Couto, Álvaro Heitor Cruz January 2009 (has links)
Made available in DSpace on 2011-12-27T14:14:04Z (GMT). No. of bitstreams: 2 000425873-0.pdf: 468713 bytes, checksum: 14f7045473cc5920546f071ff0719288 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was to evaluate the removal of metallic cores using ultrasound in the variables: relief, type of cement (zinc phosphate and glass ionomer) and root canal anatomy (circular and oval). For this, 80 healthy single-root human teeth were select (upper canines and lower incisors and lower premolars). The teeth had their crowns removed and the root canals received endodontic treatment and post space was prepared for receiving cores in Ni-Cr. The teeth were divided into eight groups (n = 10): Group 1: circular root canal with zinc phosphate, Group 2: circular root canal with zinc phosphate and group 3: oval root canal with glass ionomer and Group 4: oval root canal with glass ionomer, Group 5: oval root canal with zinc phosphate and Group 6: oval root canal with zinc phosphate, Group 7: circular root canal with glass ionomer, Group 8: circular root canal with glass ionomer. Groups 1, 3, 5, 7 received a 2mm relief in the region of cementation, around the root channel between the metallic core and cervical root portion of the tooth. After the cementation, the root portion was embedded in PVC tubes with self-cured acrylic resin. After this, the coronal portions were submitted to ultrasound and the time (s) for removal was measured. Oval root canals required more time for removal of metallic cores. Relief made around the root canal decreases the time required to perform the removal of the cores independently of cement type or root canal anatomy. / O objetivo deste estudo foi avaliar o tempo de remoção de núcleos metálicos utilizando o ultrassom, dentro das variáveis: confecção de alívio, tipo de cimento (fosfato de zinco e ionômero de vidro) e anatomia do conduto radicular (circular e oval). Para isto, foram selecionados 80 dentes humanos higidos unirradiculares (caninos superiores e inferiores, incisivos superiores e pré molares inferiores) com diâmetros radiculares. Os dentes tiveram as coroas removidas e os canais radiculares receberam tratamento endodôntico e posterior alívio de 2/3 do comprimento para receber núcleos metálicos em Ni-Cr. Os dentes foram divididos em 8 grupos (n=10): Grupo 1: conduto circular com fosfato de zinco; Grupo 2: conduto circular com fosfato de zinco; Grupo 3: conduto oval com ionômero de vidro; Grupo 4: conduto oval com ionômero de vidro; Grupo 5: conduto oval com fosfato de zinco; Grupo 6: conduto oval com fosfato de zinco; Grupo 7: conduto circular com ionômero de vidro; Grupo 8: conduto circular com ionômero de vidro. Os grupos 1, 3, 5, 7 sofreram um alívio de aproximadamente 2mm na região da cimentação, ao redor do conduto radicular, entre o núcleo metálico e a porção radicular do dente. Após o procedimento de cimentação, a porção radicular foi inclusa em tubos de PVC com resina acrílica auto-polimerizável. Em seguida as porções coronárias foram vibradas com ultrassom até a remoção e os tempo (s) foi mensurado. Os condutos com anatomia oval requereram maior tempo para remoção dos núcleos metálicos. O alívio confeccionado ao redor do conduto radicular diminui o tempo necessário para realizar a remoção do núcleo independe do tipo de cimento ou forma do conduto.
30

Utilização do cimento de fosfato de cálcio (Norian®) associado a enxertos onlay de calota craniana em região mandibular de ratos: estudo experimental : análise histológica, histométrica e biomecânica

Silveira, Roger Lanes January 2010 (has links)
Made available in DSpace on 2011-12-27T14:14:16Z (GMT). No. of bitstreams: 2 000425706-0.pdf: 3229059 bytes, checksum: 45284ea4f41049f07baee7ea1b986c3f (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This present work has analyzes the integration level of onlay bone grafts of the skull in rats’ mandibular region, combined or not with calcium phosphate cement (Norian ). For this, histology, morphometry, and biomechanical test of traction force have been evaluated. Twenty seven male Wistar rats were subjected to removal of bicortical grafts of the skullcap and fixed in the mandibular angles. The animals were divided into 6 groups: C21d – graft fixation (control – death after 21 days); I21d – graft fixation with Norian powder between the graft and recipient bed (death after 21 days), B21d - graft fixation and placement with Norian , acting as a barrier on the edges of the bone graft (death after 21 days) C55D - graft fixation (control - 55 days after death); I55d - graft fixation with Norian powder between the graft and the recepient bed (death after 55 days); B55d - graft fixation and placement with Norian , acting as a barrier on the edges of the graft (death after 55 days). The hemi-jaws on the left side were taken to the histology and histometric exam and hemi-jaws of the right to a traction force test.There was no infection in none of the cases or postoperative complications. Histological and histometric analysis – Norian ’s remnants were seen in both 21 and in 55 days, showing a gradual replacement by vascularized bone tissue; a higher bone formation was observed in the graft / bone interface receptor (GBIR) on the left side in the groups using the calcium phosphate (B21d, B55d and I55d in relation to C21d) (p = 0. 043); a better result was also observed in regard to the total newly formed bone on the left side interface of these same groups (p = 0. 08); the I55d group presented superior results than the control groups (C21d and C55d) and the group B21d concerning the GBIR bone formation on the right side (p = 0. 045); about the item on the horizontally newly formed bone on the left side, the group C21d had no significant difference in comparison to C55d, however, it presented less bone formation than the other groups that used the calcium phosphate (p = 0. 018). The traction force test - different devices have been developed to achieve an effective fixation of the specimens during the mechanical test, such as the EMIC DL-200 machine and the MTest 3. 0 version program to obtain the strength necessary to remove the grafts measured in Newton (N).The traction test demostrated that the C21d group’s results were significantly lower than other groups (p = 0. 08), furthermore, in two specimens from this group, one graft was not integrated and the other was weakly attached to the bone receptor. Comparing the control groups (21d and 55d), over time, there was a significant increase of the strenght required for the removal of the graft (p = 0. 032). The study showed good results in the use of onlay grafts associated with Norian , presenting higher levels of bone formation, even when dealing with a region of constant muscle stress. Furthermore, there was a better biomechanic integration, especially in the initial and most critical part of healing. / O presente trabalho analisou o nível de integração de enxertos ósseos onlay de calota craniana de ratos, em região mandibular, associados ou não ao cimento de fosfato de cálcio (Norian®). Para isso, foram realizadas avaliações histológicas, histométricas, além de teste biomecânico de força de tração. Vinte e sete ratos Wistar, machos, foram submetidos à remoção de enxertos bicorticais da calota craniana e fixados nos ângulos mandibulares. Os animais foram divididos em 6 grupos: C21 d - fixação do enxerto (controle - morte após 21 dias); 121 d - fixação do enxerto com o pó do Norian® entre o enxerto e o leito receptor (morte após 21 dias); B21 d - fixação do enxerto e colocação de Norian®, atuando como barreira, sobre as bordas do enxerto (morte após 21 dias); C55d - fixação do enxerto (controle - morte após 55 dias); 155d - fixação do enxerto com o pó do Norian entre o enxerto e o leito receptor (morte após 55 dias); B55d - fixação do enxerto e colocação de Norian, atuando como barreira, sobre as bordas do enxerto (morte após 55 dias). As hemimandíbulas do lado esquerdo foram destinadas ao exame histológico e histométrico e as hemi-mandíbulas do lado direito ao teste de força de tração. Em nenhum dos casos ocorreu infecção ou complicações pós-operatórias.Análise histológica e histométrica - resquícios do Norian foram vistos tanto em 21 quanto em 55 dias, demonstrando uma gradual substituição por tecido ósseo vascularizado; foi observada uma maior formação óssea na interface enxerto/osso receptor (TEOR) do lado esquerdo nos grupos que utilizaram o fosfato de cálcio (B21d, B55d e 155d em relação ao C21 d) (p= 0,043); um melhor resultado também foi observado em relação ao osso total neoformado na interface do lado esquerdo, nesses mesmos grupos W-0,08); o grupo 155d apresentou resultados superiores aos grupos controle (C21d e C55d) e ao grupo B21d na formação de osso na IEOR do lado direito (p= 0. 045): no item osso neoformado horizontalmente do lado esquerdo, o grupo C21d não apresentou diferença significativa em relação ao C55d, contudo, demonstrou haver formado menos osso que os demais grupos que utilizaram o fosfato de cálcio (p= 0,018). Teste de força de tração - diferentes dispositivos foram desenvolvidos para conseguir uma fixação eficaz dos espécimes durante o ensaio mecânico, sendo utilizada a máquina EMIC® DL-200 e o programa MTest versão 3. 0 para obtenção das forças de remoção dos enxertos em Newton (N). O teste de tração demonstrou que o grupo C21d apresentou resultados significativamente inferiores aos demais grupos (p= 0,08), além disso, em dois espécimes deste grupo, um enxerto não estava integrado e o outro estava fracamente aderido ao osso receptor. Comparando-se os grupos Controle (21d e 55d), ao longo do tempo, houve um aumento significativo na força necessária para a remoção dos enxertos (p= 0,032). O estudo demostrou bons resultados na utilização dos enxertos onlay associados ao Norian®, apresentando maior nível de formação óssea, mesmo se tratando de uma região de constante estresse muscular. Além disso, houve uma melhor integração biomecânica, principalmente na fase inicial e mais crítica da cicatrização.

Page generated in 0.0841 seconds