• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 108
  • 5
  • 5
  • 5
  • 5
  • 5
  • 1
  • Tagged with
  • 110
  • 55
  • 33
  • 30
  • 30
  • 27
  • 24
  • 23
  • 18
  • 16
  • 15
  • 14
  • 14
  • 13
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Cimentos resinosos autoadesivos : efeito do modo de polimerização no grau de conversão, na resistencia flexural biaxial e na resistencia de união a dentina / Self-adhesive resin luting : effect of curing mode on degree of conversion, biaxial flexure strength and bond strength to dentin

Aguiar, Thaiane Rodrigues 02 December 2009 (has links)
Orientador: Marcelo Giannini / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T02:32:05Z (GMT). No. of bitstreams: 1 Aguiar_ThaianeRodrigues_M.pdf: 2081066 bytes, checksum: 7befb03bacdaacad5af000ab6fe79fb2 (MD5) Previous issue date: 2009 / Resumo: A utilização de materiais que possibilitam alcançar excelência em estética, associada à redução do número de etapas presentes no protocolo de cimentação adesiva, tem destacado o interesse dos profissionais quanto ao uso dos cimentos resinosos autoadesivos. Com o recente advento destes materiais, contempla-se a necessidade em conhecer suas propriedades físicas e químicas, assim como o mecanismo de união ao substrato dental. Diante disso, este estudo teve como objetivo avaliar a influência do modo de polimerização (dupla polimerização e ativação química) de 4 cimentos resinosos sendo 3 cimentos resinosos autoadesivos (RelyX Unicem (RX), 3M ESPE, Seefeld, Alemanha; BisCem (BC), Bisco Inc., Schuamburg, IL, EUA e G-Cem (GC), GC Corp., Tóquio, Japão) e 1 cimento resinoso convencional (Panavia F 2.0 (PF), Kuraray Medical Inc., Kurashiki, Japão) quanto ao grau de conversão, resistência flexural biaxial e resistência de união à dentina. Para o ensaio de microtração, superfícies dentinárias de terceiros molares humanos foram utilizados e o padrão de fratura foi analisado em Microscopia Eletrônica de Varredura, enquanto, para os outros testes, os espécimes foram preparados a partir dos próprios cimentos resinosos com dimensões padronizadas e definidas de acordo com o ensaio aplicado. Para o estudo do grau de conversão, também foi avaliado o comportamento dos cimentos resinosos em função do tempo (5, 10 e 15 minutos), observou-se diferença estatística entre o tempo de avaliação e o modo de polimerização. A dupla polimerização aumentou os valores médios de grau de conversão para o RX e o BC; entretanto, o PF não demonstrou diferença significativa. Em relação ao tempo de avaliação, o melhor comportamento quanto ao grau de conversão foi observado 15 minutos após a manipulação dos cimentos avaliados com exceção do BC quimicamente ativado, que não demonstrou diferença estatística entre o período de 5 e 10 minutos. Para o cimento autoadesivo G-Cem, o cálculo do grau de conversão foi inviabilizado, pois não foi observado o anel aromático de carbono na leitura inicial do monômero. No ensaio de resistência flexural biaxial notou-se que a fotoativação aumentou os valores médios do módulo de flexão e da resistência à flexão; contudo, o cimento resinoso autoadesivo BC sempre apresentou os menores valores médios. O ensaio de microtração demonstrou o aumento da resistência de união dos materiais PF e GC quando fotoativados; os cimentos RX e BC não foram influenciados pelo modo de polimerização, porém, quando quimicamente ativados, o PF e RX apresentaram as maiores médias, sendo RX semelhante ao GC. O padrão de fratura apresentou predominância da falha adesiva entre dentina e cimento resinoso exceto para o grupo RX quimicamente ativado e GC fotoativado, seguido por falhas mistas envolvendo fraturas adesivas e coesivas no cimento resinoso. Conclui-se que a fotoativação dos cimentos resinosos de dupla polimerização empregados demonstrou melhores resultados na avaliação do grau de conversão, na resistência flexural biaxial e na resistência de união; entretanto, o melhor desempenho de alguns sistemas pode estar relacionado às características químicas inerentes ao material. / Abstract: The use of materials that enable excellence in esthetics, coupled with a reduction in the number of steps in the adhesive luting protocol, have aroused the interest of professionals in the use of self-adhesive resin luting. As these materials have appeared only recently, it is necessary to study the physical and chemical properties as well as the mechanism of bonding to dental substrate. Thus, the purpose of this study was to evaluate the effect of curing mode (dual and self-polymerizing) of four resin cements, of which three were self-adhesive resin cements (RelyX Unicem (RX), 3M ESPE, Seefeld, Germany; BisCem (BC), Bisco Inc., Schuamburg, IL, USA e G-Cem (GC), GC Corp., Tokyo, Japan) and one convenctional resin cement (Panavia F 2.0 (PF), Kuraray Medical Inc., Kurashiki, Japan) with regard to the degree of conversion, biaxial flexural strength and bond strength to dentin. For microtensile bond test, occlusal dentin surfaces of third human molars were used and the fractured surfaces of tested specimens were examined by scanning electron microscopy. In other tests, resin cement specimens of standard dimensions were prepared in accordance with each test applied. To study the degree of conversion, the behavior of resin cements was observed with regard to evaluation time (5, 10 and 15 minutes) and statistical difference was observed for the time of evaluation and curing mode. The mean values for RX and BC were increased when the resin cement was dual-polymerizing; however, PF showed no significant differences. With regard to the time of evaluation, the highest degree of conversion was observed 15 minutes after the cement was manipulated for all the groups evaluated, except when BC was auto-polymerized after 5 and 10 minutes. For the resin cement G-Cem it was not possible to calculate the degree of conversion, because no aromatic carbon ring was shown during the initial measurement of the monomer. For biaxial flexural strength, dual-polymerizing of the resin cement produced higher flexural modulus and strength; however, the resin cement BC always showed the lowest values. The tensile bond strength showed higher bond strength for PF and GC when light polymerized. The resin cements RX and BC were not influenced by the polymerization mode. However, when the systems were self-polymerizing, PF and RX showed the best results and RX was similar to GC. The failure pattern presented a predominance of adhesive failures between dentin and resin cement, except when RX was self-polymerized and G-Cem light polymerized, followed by mixed fractures, involving adhesive failure and cohesive fractures of the resin cement. It was concluded that light activation of the dual-polymerized resin cements used, showed highest degrees of conversion, biaxial flexural strength and microtensile bond strength. However, the better performance of some cementing systems may be associated with the chemical characteristics inherent to the material. / Mestrado / Dentística / Mestre em Clínica Odontológica
12

Influência do pré-aquecimento na resistência de união de agentes cimentantes utilizados para a fixação de pinos de fibra de vidro = Influence of pre-heating on the bond strength of fiber posts cemented with different lutting agents / Influence of pre-heating on the bond strength of fiber posts cemented with different lutting agents

Hernandes da Fonseca, Natália Maria Aparecida, 1986- 27 August 2018 (has links)
Orientador: Flávio Henrique Baggio Aguiar / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-27T07:51:28Z (GMT). No. of bitstreams: 1 HernandesdaFonseca_NataliaMariaAparecida_D.pdf: 1562377 bytes, checksum: a4799c4175306d178b320a7dce350a1e (MD5) Previous issue date: 2015 / Resumo: Este estudo in vitro avaliou a influência do pré-aquecimento na resistência de união de três agentes utilizados para a cimentação de pinos de fibra de vidro Reforpost nº 2. Para tal propósito, foram utilizadas 42 raízes de pré-molares humanos previamente extraídos e com tratamento endodôntico realizado e foram divididos, aleatoriamente, em 6 grupos (n=7) de acordo com o agente de fixação (um cimento resinoso dual Rely X ARC; um cimento autoadesivo Rely X U200; e uma resina composta de baixa viscosidade SureFil SDR flow) e temperatura de pré-aquecimento (23ºC; 54ºC). Todos os agentes de cimentação foram fotoativados através de uma fonte de luz LED com irradiância de 1100 mW/cm² durante 40 segundos. As raízes foram armazenadas em água destilada à 37ºC por sete dias e foram cortadas em fatias com espessura de 1,0 mm cada, os quais foram divididos de acordo com o terço do canal radicular (cervical; médio; apical). Em seguida, as amostras foram submetidas ao teste de resistência ao cisalhamento por extrusão para a mensuração em cada terço do canal radicular. Os dados foram submetidos à ANOVA 3 critérios com parcelas subdivididas e teste de Tukey (? = 0,05). Foram encontradas diferenças significativas entre os três cimentos resinosos. (P < 0,0017); no entanto não foram encontradas diferenças entre os grupos não aquecidos e os grupos pré-aquecidos, diferentes regiões da raiz ou para qualquer interação entre os fatores (p > 0,05). Os grupos cimentados com o cimento resinoso Rely X ARC apresentou maiores resultados de resistência de união do que os grupos cimentados com a resina de baixa viscosidade SureFil SDR flow. O cimento autoadesivo Rely X U200 obteve resistência de união intermediária, sem diferença estatística para RelyX ARC ou SureFil SDR flow. Assim, conclui-se que, a utilização de cimento dual convencional pode ser indicada para cimentação de pinos de fibra de vidro e que o pré-aquecimento de cimentos resinosos não é efetivo para o aumento da resistência de união de pinos pré-fabricados / Abstract: This in vitro study investigated the influence of pre-heating on the bond strength of three agents used for cementing fiber posts Reforpost # 2. For that, forty-two human premolars roots with endodontic treatment performed were randomly divided into 6 groups (n = 7), according with the luting agent (a dual resin cement Rely X ARC; a self-adhesive cement Rely X U200; and a flowable composite SureFil SDR flow) and the pre-heating temperature (23° C; 54° C). All luting agents were light-cured with a LED unit ¿ 1,100 mW/cm² for 40 seconds. The roots were stored in distilled water at 37° C for seven days and after that, the roots were cut into slices of 1.0 mm thickness each, which were divided according to the third of the root canal (cervical; middle; apical). Then the specimens were submitted to push out test to measure the bond strength in each third of the root canal. Data were submitted to three-way split-spot ANOVA and Tukey's test (? = 0.05). Significant differences were found among the three luting agent studied (p < 0.0017); however, no difference was found among the pre-heating temperature, root segments or for any interaction between the factors (p > 0.05). Groups luted with resin cement Rely X ARC showed significant higher retentive strength than flowabe composite SureFil SDR flow. Rely X U200 showed intermediary retentive strength means, without statistical difference for Rely X ARC or SureFil SDR flow. Thus, it is concluded that the use of conventional dual cement should be indicated to luting fiber posts and the resin cement pre-heating is not effective to increase the retentive strength of fiber post / Doutorado / Dentística / Doutora em Clínica Odontológica
13

Avaliação histológica e histomorfométrica do comportamento ósseo em relação à profundidade da linha marginal de cimentação de próteses sobre implantes Cone Morse: estudo experimental em cães / Histologic and histomorphometric evaluation of bone behavior in relation to the depth of the line of marginal cementation on Morse taper implants: experimental study in dogs

Stancari, Fernanda Herrera 18 May 2015 (has links)
A utilização dos implantes cone morse muito favorece a estética peri-implantar e seu uso em conjunto com próteses cimentadas favorece ainda mais a estabilidade do sistema, simplificando também os procedimentos protéticos. O presente estudo histológico e histomorfométrico utilizou os implantes cone morse com o intuito de avaliar o comportamento tecidual com relação à posição da margem da cimentação protética em relação ao tecido ósseo quando se faz o uso próteses cimentadas. Foram utilizados quatro cães, os quais tiveram todos os pré-molares inferiores extraídos numa primeira fase cirúrgica. Após três meses, realizou-se a segunda fase cirúrgica, na qual foi realizada a técnica da carga imediata, com a instalação dos implantes juntamente com os pilares protéticos. Foram instalados vinte e quatro implantes numa profundidade de 3 mm infra óssea e eles foram igualmente divididos entre os grupos Controle e Experimental. Os pilares protéticos utilizados foram do tipo munhão universal e apresentavam diferentes alturas transmucosas iguais a 1.5 mm, 3.5 mm, e 5.5 mm. Isto fez com que a margem da cimentação se posicionasse a 1.5 mm infra óssea, a 0.5 mm supra óssea e a 2.5 mm supra óssea. No grupo Controle, foi realizada a instalação dos implantes e dos pilares protéticos somente. No grupo Experimental, foi realizada a instalação dos implantes, dos pilares protéticos e, sobre estes, foram cimentados cilindros de alumina. Os animais permaneceram sobre controle de placa durante 10 semanas subsequentes a instalação dos implantes, sendo este o tempo final do experimento através da realização da eutanásia. As amostras foram preparadas para análise histológica e avaliação dos tecidos peri-implantares. A região de interesse foi medida através da distância entre a margem do pilar protético e a porção mais coronal da crista óssea peri-implantar. Foram utilizados os testes estatísticos ANOVA a três critérios com medidas repetidas e teste de Tukey com o nível de significância de p < 0.05. Os resultados mostraram que não houve diferenças estatisticamente significantes entre os grupos Controle e Experimental (p = 0.2764) e que os pilares de 1.5 mm mostram menos perda óssea comparada aos outros pilares, considerando que a distância média da remodelação óssea foi menor neste grupo (0.6859 mm) comparada com os pilares de 3.5 mm (1.2917 mm) e 5.5 mm (1.0823 mm). Conclui-se que não há influência da profundidade da margem da cimentação protética no comportamento da crista óssea e que a utilização de diferentes alturas dos pilares protéticos não parece alterar o tecido ósseo marginal ao redor dos implantes Cone Morse. / The use of Morse taper implants has increased because of some positive features. Cemented crowns can be extensively used, taking advantage of the system connection stability, also simplifying the prosthetic procedures. The present histological and histomorphometric study used Morse taper implants with the purpose of evaluating bone behavior with respect to the cementation margin position of the prosthetic crown. Four dogs had all premolars extracted at a first surgical procedure. After three months, there was a second surgical procedure with simultaneous installation of implants and abutments, submitted to immediate load. Twenty four implants were installed 3 mm below the bone level and they were equally divided between Control and Experimental groups. The universal post abutments used had three different transmucosal heights, 1.5 mm, 3.5 mm and 5.5 mm. Thus there were implants with the level of the cementation margin positioned 1.5 mm below the bone level, as well as 0.5 mm and 2.5 mm above the bone level. In the Control group, installation of implants and abutments only was performed. In the Experimental group immediately after the placement of implants and abutments alumina cylinders were cemented. The animals were kept on plaque control for 10 weeks after implant placement and then euthanized. Samples were prepared for histological analysis and evaluation of peri-implant tissues. The region of interest was measured by the distance between the prosthetic margin of the abutment to the most coronal peri-implant bone crest. ANOVA test at three criteria with repeated measures and Tukey test with a significance level of p < 0.05 were applied. The results showed no statistically significant differences between Control and Experimental groups (p = 0.2764). The 1.5 mm abutments presented less bone loss compared to all other abutments tested, because the distance average of bone remodelation was shorter in this group (0.6859 mm) compared to the 3.5 mm abutment (1.2917 mm) and the 5.5 mm one (1.0823 mm). Conclusion: There is no influence of the depth of prosthetic marginal cementation on the behavior of bone crest and the use of different transmucosal heights of abutments does not seem to change the marginal bone surrounding morse taper implants.
14

Efeito do envelhecimento na resistência adesiva da zircônia após diferentes tratamentos de superfície / Effect of water aging on bond strength of zirconia after different surface treatments

Santos, Livia Aguiar 02 September 2015 (has links)
Este estudo teve o objetivo de avaliar, por meio do ensaio de microtração, o efeito na resistência adesiva e no modo de fratura da Y-TZP quando cimentada a blocos padronizados de resina composta com um cimento resinoso autoadesivo (RelyX Unicem 3M ESPE, Saint Paul/ Minnesota, EUA), sob diferentes tratamentos de superfície, antes e após o envelhecimento. Doze amostras de Y-TZP foram divididas em seis grupos, de acordo com os seguintes tratamentos de superfície: Ru (sem tratamento de superfície); Ap (Alloy Primer); Zp (Z-Prime Plus); Na (solução de hidróxido de sódio - NaOH); NaAp (solução de NaOH, seguida pela aplicação de Alloy Primer); NaZp (NaOH, seguida pela aplicação de Z-Prime Plus). Após os tratamentos de superfície e a cimentação, de acordo com as recomendações do fabricante, os blocos foram armazenados por 24h em água destilada e cortados em seguida. O teste de microtração aconteceu em dois momentos: 72h após os procedimentos de corte e após seis meses de envelhecimento (E). Ao final do teste de microtração, os espécimes foram analisados em estereomicroscópio e no microscópico eletrônico de varredura (MEV), para caracterização do modo de fratura. A distribuição Weibull a dois parâmetros (Synthesis 9, Weibull ++; Reliasoft, Tucson, AZ, USA) foi utilizada para cálculo da probabilidade de sobrevida em função da resistência adesiva em 10 MPa, 15 MPa e 20 MPa. A comparação entre os grupos também foi realizada com o módulo de Weibull e a resistência característica (resistência adesiva). As resistências adesivas imediatas e após o envelhecimento foram: (Ru 15,26 MPa e RuE 12,15 MPa; Ap 13,82 MPa e ApE 10,72 MPa; Zp 14,19 MPa e ZpE 9,72 MPa; Na 17,92 MPa e NaE 13,15 MPa; NaAp 21,25 MPa e NaApE 18,13 MPa; NaZp 16,25 MPa e NaZpE 8,66 MPa). Nos grupos imediatos, a utilização da solução básica, sozinha ou associada aos primers, apresentaram maior quantidade de falhas mistas, porém, após o envelhecimento, as falhas adesivas foram mais frequentes para esses tratamentos. Através dos resultados obtidos, pôde-se concluir que a solução de NaOH associada ao Alloy Primer, foi o único tratamento de superfície que apresentou os maiores valores de resistência adesiva, antes e após o envelhecimento, apresentando modo de fratura predominantemente mista. O tempo de armazenamento levou a uma redução da probabilidade de sobrevida em função da carga de 10 MPa e 15 MPa para todos os tratamentos, exceto para o NaAp. / This study aimed to evaluate, through microtensile test, the effect of bond strength and fracture modes of the Y-TZP when it is cemented to a standard composite resin blocks with a self-adhesive resin cement (RelyX Unicem - 3M ESPE, Saint Paul / Minnesota, USA) under different surface treatments before and after aging. Twelve samples of Y-TZP were divided into six groups, according to the following surface treatments: Ru (no surface treatment); Ap (Alloy Primer); Zp (ZPrime Plus); Na (sodium hydroxide solution - NaOH); NaAp (NaOH solution, followedby Alloy Primer); NaZp (NaOH solution, followed by Z-Prime Plus). After the surface treatment and cementation, according to the manufacturer\'s recommendations, the blocks were stored for 24 hours in distilled water and then cut. The microtensile testing was performed in two times: 72 hours after the cutting procedures and after six months of aging (E). At the end of microtensile test, the specimens were analyzed in stereomicroscope and scanning electron microscope (SEM) to characterize the fracture mode. The 2-parameter Weibull distribution (Synthesis 9, Weibull ++; Reliasoft, Tucson, AZ, USA) was used to calculate the survival probability function of the adhesive strength at 10 MPa, 15 MPa and 20 MPa. Comparisons between groups were also analysed with Weibull modulus and characteristic strength (bond strength). Results showed that the immediate and after aging bond strength were: (Ru 15.26 MPa and RuE 12.15 MPa; Ap - 13.82 MPa and ApE - 10.72 MPa; Zp - 14.19 MPa and ZpE - 9.72 MPa; Na - 17.92 MPa and NaE - 13.15 MPa; NaAp 21.25 MPa and NaApE - 18.13 MPa; NaZp 16.25 MPa and NaZpE - 8.66 MPa). In the immediate groups, using the basic solution, alone or in association with primers the results showed an increased amount of mixed failures, but after aging, the adhesive failures was more frequent for such treatments. It was possible to conclude that the NaOH solution associated with the Alloy Primer was the only surface treatment that showed the highest bond strength values before and after aging, with predominantly mixed fracture mode. The storage time promoted a reduction in survival probability function load of 10 MPa and 15 MPa for all treatments except for the NaAp.
15

Resistência à remoção por tração de coroas NiCr cimentadas sobre munhões usinados em liga de titânio, irradiados ou não por LASER / Tensile strenght of NiCr crowns cemented upon usinated titanium alloy abutments, LASER irradiated or not

Toledo, Fabiane Lopes 24 May 2007 (has links)
No presente trabalho, usando ensaios de remoção por tração, o objetivo foi avaliar a eficiência de 4 agentes (fosfato de zinco S. S.White, ionômero de vidro Ketac Cem Easymix, resina composta RelayX Luting 2 e resina acrílica especial Panavia 21 TC) usados para fixar coroas totais de NiCr a munhões tronco-cônicos, usinados em liga de Ti-6Al-4V. Dentre os cinqüenta munhões utilizados, 40 permaneceram com sua superfície original altamente lisa (como vieram de fábrica) e foram distribuídos em grupos de 10, para cada agente cimentante; no grupo dos 10 restantes existiu uma modificação por irradiação com LASER e cimentação apenas com fosfato. Os ensaios mecânicos foram realizados em uma máquina universal MTS 810, na velocidade de 0,5 mm/min. A respectiva Análise de Variância (ANOVA) apontou existir diferença significante entre os grupos e o teste de Tukey (p<0,05) também mostrou diferenças significantes entre eles, exceto nas comparações original/fosfato versus original/RelayX e original/fosfato versus original/KetcCem. Para os munhões não-irradiados, o melhor desempenho foi apresentado pela resina Panavia 21 (1.127,996 N); a resina composta RelyX (478,197 N) mostrou comportamento similar apenas ao do fosfato (430,662 N), o qual apresentou desempenho semelhante ao ionômero de vidro KetacCem (227,705 N). A modificação da superfície do munhão fez com que a magnitude da resistência à tração das coroas cimentadas com fosfato aumentasse para 1.514,872 N. / By means of tensile essays, NiCr total crowns were removed from usinated tronco-conical abutments composed by an Ti-6Al-4V alloy; the performance of 4 cementig agents (S. S. White zinc phoshate, Ketac Cem Easymix glass ionomer, RelayX Luting 2 composite resin and Panavia 21 TC special acrylic resin) was evaluated. Among a total of 50 abutments, 40 were used with it surface presenting high smoothness (as they come from manufacturer) and distributed in groups of 10 elements, each group for each cementing agent; the other 10 abutments had had its surfaces modified by LASER and were used only with phosphate. The mechanical essays were developed at a MTS 810 universal machine, adjusted to a 0.5 mm/m velocity. The ANOVA applied to data pointed out the existence of significant differences between groups; the subsequent Tukey´s test (p<0.05) also detected significant differences, except at comparisons of original/phosphate versus original/ RelayX and original/phosphate versus original/ KetacCem. To non-irradiated abutments, the better performance was presented by Panavia 21 (1,127.996 N); RelyX (478.197 N) showed itself similar only to phosphate (430.662 N), wich had a performance similar to that of KetacCem (227.705 N). The referred LASER irradiation promoted an increased resistance to the phosfate, which reached 1,514.872 N.
16

Estudos dos efeitos de aditivos químicos na cimentação de rejeitos radioativos gerados em reatores do tipo PWR - concentrado do evaporador / Waste storage; Cementing; PWR type reactors

Vanessa Mota Vieira 27 February 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Nesta pesquisa foram estudados os efeitos de aditivos químicos no processo de cimentação de rejeitos radioativos. Estes aditivos são utilizados para melhorar propriedades da pasta e do produto solidificado contendo estes rejeitos. Há uma grande variedade destes materiais no mercado, porém eles são frequentemente alterados ou simplesmente excluídos, portanto é essencial conhecer os aditivos disponíveis comercialmente e seus efeitos. Os testes foram realizados com uma solução simulando os rejeitos do concentrado do evaporador gerado em reatores nucleares do tipo PWR (Pressurized Water Reactor). Para a sua cimentação foram utilizadas duas formulações, A e C, incorporando-se maior ou menor quantidade de rejeito, respectivamente. Acrescentaram-se aditivos químicos de dois fabricantes diferentes (S e H), sendo eles: aceleradores e retardadores de pega e superfluidificantes. Os experimentos foram organizados seguindo o planejamento fatorial 23 para quantificar os efeitos das formulações, dos aditivos, de suas quantidades e de seus fabricantes nas propriedades da pasta e do produto cimentado. Os parâmetros avaliados foram: a viscosidade, o tempo de pega, as densidades da pasta e do produto e a resistência à compressão. Os superfluidificantes forneceram os melhores resultados de viscosidade (trabalhabilidade), densidade e tempo de pega. Os aceleradores de pega apresentaram os maiores valores de resistência à compressão, aos 28 dias de idade, e os menores valores de densidade. Para o parâmetro tempo de pega, o uso destes aceleradores e retardadores de pega seria recomendado somente para casos específicos. Todos os resultados de resistência à compressão atenderam aos requisitos dos órgãos reguladores, com exceção da mistura com a menor quantidade de superfluidificante do fabricante S. A utilização do superfluidificante permite a cimentação em sistemas de misturas mais simples e de menor custo, diferentemente do uso de retardador e acelerador de pega que necessitam de sistemas de mistura específicos. Apresentam pastas mais homogêneas e maior qualidade dos produtos solidificados. Os maiores valores de densidade foram obtidos utilizando o Superfluidificante, pois o seu uso tornou a pasta mais fluída e com melhor trabalhabilidade, diminuindo assim o aparecimento de poros e imperfeições. De modo geral, o uso do superfluidificante apresentou melhores resultados nos parâmetros avaliados. / In this research it has been studied the effects of chemical admixtures in the cementation process of radioactive wastes. These additives are used to improve the properties of waste cementation process, both of the paste and of the solidified product. However there are a large variety of these materials that are frequently changed or taken out of the market. Then it is essential to know the commercially available materials and their effects. The tests were carried out with a solution simulating the evaporator concentrate waste coming from PWR nuclear reactors (Pressurized Water Reactor). It was cemented using two formulations, A and C, incorporating higher or lower amount of waste, respectively. It was added chemical admixtures from two different manufacturers (S and H), which were: accelerators, set retarders and superplasticizers. The experiments were organized by a factorial design 23 to quantify the effects of formulations, admixtures, their quantity and manufacturer in properties of the paste and products. The measured parameters were: the viscosity, the setting time, the paste and product density and the compressive strength. The superplasticizers provided the best results of viscosity (workability), density and setting time. The accelerators showed the highest values of compressive strength, at age of 28 days, and the lowest values of density. In relation to the setting time, set retarders and accelerators would be recommended only for specific cases. All results of compressive strength met the requirements of regulators, except for the mixture with the lower amount of superplasticizers from the manufacturer S. The use of superplasticizers allows the cementation systems of mixtures simpler and lower cost, differently from the use of set retarders and accelerators which require particular mixing systems. Presented paste more homogeneous and better quality products solidified. The highest density values were obtained using Superfluidificante, since their use became more fluid and the pastes with better workability, thereby reducing the appearance of pores and imperfections. In general, the use of superfluidificante showed better results in all evaluated parameters.
17

Efeito de nanofilmes depositados a plasma na resistência de união de um cimento resinoso a uma cerâmica à base de zircônia /

Figueiredo, Viviane Maria Gonçalves de. January 2014 (has links)
Orientador: Lafayette Nogueira Júnior / Co-orientador: Marcos Massi / Banca: Renato Sussumu Nishioka / Banca: Argemiro Soares da Silva Sobrinho / Banca: Eron Toshio Colauto Yamamoto / Banca: Rubens Nisei Tango / Resumo: Esta pesquisa objetivou avaliar o efeito de diferentes nanofilmes depositados a plasma na resistência de união entre cimento resinoso e cerâmica à base de zircônia. 120 blocos/espécimes (15,2 x 12,5 x 1,7 mm) e 18 discos (11,0 x 1,4 mm) de zircônia (Y-TZP) (VITA In-Ceram Zirconia, Vita Zahnfabrik, Alemanha) receberam diferentes tratamentos de superfície (n = 20 para os blocos) (n = 3 para discos): zircônia sem tratamento (Zrpolida), jateamento de alumina revestida por sílica (30 μm) (Zrjat#), nanofilme à base de sílica (ZrSiO2), jateamento de alumina (45 μm) + nanofilme à base de sílica (Zrjat+SiO2), e nanofilme à base de fluoreto (ZrF) e jateamento de alumina (45 μm) + nanofilme à base de fluoreto (Zrjat+F). Os nanofilmes foram depositados por meio da técnica a plasma PECVD. As superfícies cerâmicas foram caracterizadas pela morfologia (MEV e MFA), química (XPS) e molhabilidade (ângulo de contacto), realizada nos discos. O agente de união silano foi aplicado em cada superfície e um cilindro de cimento resinoso foi construído sobre os espécimes tratados. Metade dos espécimes de cada grupo (n = 10) foram submetidos a 6.000 ciclos térmicos. A resistência de união foi avaliada pelo teste de cisalhamento e análise fractográfica pelo estereomicroscópico, MEV e EDS. Para análise estatística utilizou-se ANOVA 1-Fator e o teste de Tukey, para presença e ausência de envelhecimento (p = 0,05). A zircônia apresentou-se mais hidrofílica após a deposição dos nanofilmes. Ligações químicas entre Si-O foram encontradas em ZrSiO2; ZrF promove um processo de fluoração na superfície da cerâmica Y-TZP, convertendo-a em oxifluoreto de zircônio. Os valores de resistência de união iniciais obtidos pelos tratamentos de superfície a plasma não superaram os valores de união da silicatização. Após o envelhecimento, todas as amostras do grupo ZrSiO2(TC) sofreram falhas pré-teste. OS valores de resistência de.... / Abstract: This study aimed to evaluated the effects of differents plasma nanofilms on the bond strength between resin cement and zirconia ceramic. 120 blocks / specimens (15.2 x 12.5 x 1.7 mm) and 18 discs (11.0 x 1.4 mm) of zirconia (Y-TZP) (VITA In-Ceram Zirconia, Vita Zahnfabrik, Germany) received differents treatments surface (n = 20 for the blocks) (n = 3 for discs): untreated zirconia (Zrpolida), silica-coated (30 μm) (Zrjat#), silica nanofilm (ZrSiO2), sandblasted by air-borne particle abrasion with aluminum oxide particles (45 μm) + silica nanofilm (Zrjat+SiO2) and fluoride nanofilm (ZrF) and sandblasted by air-borne particle abrasion with aluminum oxide particles (45 μm) + fluoride nanofilm (Zrjat+F). The nanofilms were deposited by PECVD technique of the plasma. The ceramic surfaces were characterized by morphology (SEM and AFM), chemical (XPS) and wettability (Contact angle), that was performed on discs. The silane agent was applied to each surface treatment and a cylinder of resin cement was built on the specimens. Half of the samples of each group (n = 10) were subjected to 6.000 thermalcycles. The bond strength was evaluated by shear test and fractographic analysis by stereoscopic, SEM and EDS. Statistical analysis was performed using one-way ANOVA and Tukey's test for the presence and absence non-aged (p = 0.05). Zirconia presented more hydrophilic after nanofilms deposition. Chemical bonds between Si-O were found in ZrSiO2; ZrF promotes a process of fluorination on the Y-TZP surface, promoting the conversion of zirconia in zirconium oxyfluoride. The initial values of bond strength obtained by plasma treatment did not exceed the bond values of the silica-coated. After aging, all samples of the group ZrSiO2 (TC) falied. The values of bond strength of ZrF (TC) (3.8 MPa) were lower than Zrjat# (TC) (15.4 MPa) and Zrpolida (TC) (6.3 MPa). The silica nanofilm showing detachment after shearing. Adhesive failures were predominant among the... / Doutor
18

Estudo do comportamento mecanico de um solo artificialmente cimentado / Study of the mechanical behavior of an arti ficially cemented soil

Prietto, Pedro Domingos Marques January 1996 (has links)
A melhoria das características mecânicas de solos naturais constitui uma técnica de crescente utilização na engenharia geotécnica, em especial na execução de fundações sobre solos moles . Algumas soluções passam pela utilização de materiais geotécnicos cimentados , tais como o solo-cimento, o solo-cal, etc. Estas aplicações, no entanto, requerem o conhecimento das características de deformação e de resistência dos materiais utilizados. No presente trabalho, a partir de um programa experimental que incluiu ensaios de resistência à compressão simples, ensaios triaxiais drenados (CID) com medição interna de deformações axiais, e microscopia eletrõnica de varredura, um solo arenoso artificialmente cimentado teve seu comportamento mecânico investigado, frente à variação do grau de cimentação (0, 1, 3 e 5% de adição de cimento Portland) e da tensão efetiva média inicial (p;' = 20, 60 e Os resultados mostraram que o comportamento do solo cimentado foi i nfluenciado por ambas as variáveis investigadas . No entanto, para a faixa de tensões efetivas estudada, o comportamento foi basicamente comandado pelo grau de cimentação. Visando a aplicação do material investigado em. projetos geotécnicos, uma abordagem é proposta para a determinação da resistência ao cisalhamento drenada e do módulo de deformação estática. A inclusão na análise de outros resultados encontrados na literatura permitiram ampliar alguns aspectos desta abordagem. / The improvement of natural soils characteristics is a largely used process in geotechnical engineeringf specially in foundation designs on soft grounds. Sometimesf cemented materialsf l ike soilcement and soil-lime admixtures f are employed. These applications require the knowledge of the strain and strength characteristics of materials . In this work an experimental programme was carried out to investigate the mechanical behavior of an artificially cemented sandy soilf which includes unconfined compression tests f drained triaxial compression tests (CID) with local measurements of axial strains f and scanning electron microscopy analysis. The influence of cementation level (O f l f 3 and 5% Portland cement content) and ini tial mean effecti ve stress ( p;' = 20 f 60 and 100 kN/m2 ) were evaluated . Test results have demonstrated t hat the cemented soil behavior was significantly affected by bothf cementation level and i nitial mean effective stress . However f for the range of eff ect ive stresses investigated herein f soil behavi or was mainly controlled by cementation level . Finally f to allow the application of t he investigated material into geotechnical worksf an approach is proposed to determinate the drained shear strength and the static deformati on moduli of the cemented soil. Data from other investigation programmes were incorporated to the present study to allow generalization of some aspects of the proposed approach.
19

Avaliação histológica e histomorfométrica do comportamento ósseo em relação à profundidade da linha marginal de cimentação de próteses sobre implantes Cone Morse: estudo experimental em cães / Histologic and histomorphometric evaluation of bone behavior in relation to the depth of the line of marginal cementation on Morse taper implants: experimental study in dogs

Fernanda Herrera Stancari 18 May 2015 (has links)
A utilização dos implantes cone morse muito favorece a estética peri-implantar e seu uso em conjunto com próteses cimentadas favorece ainda mais a estabilidade do sistema, simplificando também os procedimentos protéticos. O presente estudo histológico e histomorfométrico utilizou os implantes cone morse com o intuito de avaliar o comportamento tecidual com relação à posição da margem da cimentação protética em relação ao tecido ósseo quando se faz o uso próteses cimentadas. Foram utilizados quatro cães, os quais tiveram todos os pré-molares inferiores extraídos numa primeira fase cirúrgica. Após três meses, realizou-se a segunda fase cirúrgica, na qual foi realizada a técnica da carga imediata, com a instalação dos implantes juntamente com os pilares protéticos. Foram instalados vinte e quatro implantes numa profundidade de 3 mm infra óssea e eles foram igualmente divididos entre os grupos Controle e Experimental. Os pilares protéticos utilizados foram do tipo munhão universal e apresentavam diferentes alturas transmucosas iguais a 1.5 mm, 3.5 mm, e 5.5 mm. Isto fez com que a margem da cimentação se posicionasse a 1.5 mm infra óssea, a 0.5 mm supra óssea e a 2.5 mm supra óssea. No grupo Controle, foi realizada a instalação dos implantes e dos pilares protéticos somente. No grupo Experimental, foi realizada a instalação dos implantes, dos pilares protéticos e, sobre estes, foram cimentados cilindros de alumina. Os animais permaneceram sobre controle de placa durante 10 semanas subsequentes a instalação dos implantes, sendo este o tempo final do experimento através da realização da eutanásia. As amostras foram preparadas para análise histológica e avaliação dos tecidos peri-implantares. A região de interesse foi medida através da distância entre a margem do pilar protético e a porção mais coronal da crista óssea peri-implantar. Foram utilizados os testes estatísticos ANOVA a três critérios com medidas repetidas e teste de Tukey com o nível de significância de p < 0.05. Os resultados mostraram que não houve diferenças estatisticamente significantes entre os grupos Controle e Experimental (p = 0.2764) e que os pilares de 1.5 mm mostram menos perda óssea comparada aos outros pilares, considerando que a distância média da remodelação óssea foi menor neste grupo (0.6859 mm) comparada com os pilares de 3.5 mm (1.2917 mm) e 5.5 mm (1.0823 mm). Conclui-se que não há influência da profundidade da margem da cimentação protética no comportamento da crista óssea e que a utilização de diferentes alturas dos pilares protéticos não parece alterar o tecido ósseo marginal ao redor dos implantes Cone Morse. / The use of Morse taper implants has increased because of some positive features. Cemented crowns can be extensively used, taking advantage of the system connection stability, also simplifying the prosthetic procedures. The present histological and histomorphometric study used Morse taper implants with the purpose of evaluating bone behavior with respect to the cementation margin position of the prosthetic crown. Four dogs had all premolars extracted at a first surgical procedure. After three months, there was a second surgical procedure with simultaneous installation of implants and abutments, submitted to immediate load. Twenty four implants were installed 3 mm below the bone level and they were equally divided between Control and Experimental groups. The universal post abutments used had three different transmucosal heights, 1.5 mm, 3.5 mm and 5.5 mm. Thus there were implants with the level of the cementation margin positioned 1.5 mm below the bone level, as well as 0.5 mm and 2.5 mm above the bone level. In the Control group, installation of implants and abutments only was performed. In the Experimental group immediately after the placement of implants and abutments alumina cylinders were cemented. The animals were kept on plaque control for 10 weeks after implant placement and then euthanized. Samples were prepared for histological analysis and evaluation of peri-implant tissues. The region of interest was measured by the distance between the prosthetic margin of the abutment to the most coronal peri-implant bone crest. ANOVA test at three criteria with repeated measures and Tukey test with a significance level of p < 0.05 were applied. The results showed no statistically significant differences between Control and Experimental groups (p = 0.2764). The 1.5 mm abutments presented less bone loss compared to all other abutments tested, because the distance average of bone remodelation was shorter in this group (0.6859 mm) compared to the 3.5 mm abutment (1.2917 mm) and the 5.5 mm one (1.0823 mm). Conclusion: There is no influence of the depth of prosthetic marginal cementation on the behavior of bone crest and the use of different transmucosal heights of abutments does not seem to change the marginal bone surrounding morse taper implants.
20

Influência do envelhecimento no grau de adaptação marginal de coroas protéticas confeccionadas em zircônia

Luna, Maria Del Pinal January 2017 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2017. / Made available in DSpace on 2017-05-31T14:18:23Z (GMT). No. of bitstreams: 1 345802.pdf: 2808706 bytes, checksum: b1c922798dff25394a856877feda3b8c (MD5) Previous issue date: 2017 / Apesar do uso da zircônia em diversas aplicações técnicas e biomédicas, após 20 anos de pesquisa, a possibilidade de este material envelhecer em função, fenômeno conhecido como degradação em baixas temperaturas (DBT), continua sendo um assunto em controvérsia. O objetivo deste estudo "in vitro" foi analisar a influência do envelhecimento no grau de adaptação de coroas bilaminares feitas em Y-TZP (Z-CAD HD, Metoxit AG, Suíça) e recobertas com cerâmica (E-max, Ivoclar Vivadent, Liechtenstein) e coroas monolíticas (Z-CAD HTL, Metoxit AG, Suíça), assim como a influência do agente de cimentação (Rely X U200, 3M Espe, EUA) no grau de adaptação marginal dessas peças cerâmicas. Quarenta e oito corpos de prova foram usinados em aço inoxidável simulando um primeiro pré-molar inferior que receberia uma coroa protética. Os corpos de prova foram divididos aleatoriamente em quatro grupos com 12 espécimes cada e, após, foram confeccionadas as seguintes coroas: (1) coroas bilaminares (infraestrutura em zircônia e cerâmica de cobertura) cimentadas; (2) coroas bilaminares (infraestrutura em zircônia e cerâmica de cobertura) não cimentadas; (3) coroas monolíticas em zircônia não cimentadas; (4) coroas monolíticas em zircônia cimentadas. Em relação ao envelhecimento, todos os grupos foram submetidos a dois tempos diferentes: T1: nenhum tratamento de envelhecimento e armazenamento em ambiente seco e temperatura ambiente. T2: tratamento de envelhecimento artificial em autoclave, sob uma atmosfera úmida a 131°C e pressão de 1,7 bares durante 5 horas. A adaptação marginal foi avaliada pela medida da discrepância marginal absoluta das coroas realizadas, utilizando um microscópio eletrônico de varredura. A difração de raios X foi utilizada para calcular a fração de fase monoclínica e monitorizar a DBT. Tanto as coroas bilaminares como as monolíticas apresentaram discrepâncias marginais verticais semelhantes, entretanto, não foram observadas diferenças significativas na adaptação marginal entre os grupos testados (p= 0,41). Também não foram observadas diferenças na discrepância marginal quanto à presença ou não de agente de cimentação e quando o envelhecimento artificial foi empregado (p= 0,17). A intensidade do pico da fase monoclínica a tetragonal aumentou de 1,2 a 3% para as coroas bilaminares e de 0,8 a 1,6% para as coroas monolíticas. As coroas monolíticas e bilaminares de zircônia confeccionadas mediante tecnologia CAD/CAM apresentaram gaps marginais que estavam dentro de uma faixa aceitável de discrepância marginal. A cimentação não demonstrou ter uma influência significativa no ajuste marginal. A adaptação marginal não foi influenciada pelo envelhecimento, e este não levou a uma transformação significativa da fase tetragonal para a fase monoclínica. Estudos "in vitro" demonstraram que a tecnologia CAD / CAM pode produzir estruturas de zircônia com um ajuste marginal clinicamente aceitável. Com base na ausência de estudos científicos longitudinais, não parece claro a relação entre o ajuste marginal e a consequente degradação do envelhecimento.<br> / Abstract : Despite the use of Yttria Tetragonal Zirconia Polycrystal (3Y-TZP) in several technical and biomedical applications, after over 20 years of research, the possibility that this material can aged in function, a phenomenon known as low temperature degradation (LTD), remains a subject under discussion. The aim of this "in vitro" research was to analyze the influence of aging on the degree of adaptation of Y-TZP based crowns, either monolithic (Z-CAD HTL, Metoxit AG, Tayngen, Switzerland) or ceramic coating (Z-CAD HD, Metoxit AG, Tayngen, Switzerland; E-max, Ivoclar Vivadent) as well as the influence of cementation (Rely X U200, 3M Espe) on the fit of the restorations. Forty-eight standardized dies will be prepared from stainless steel, to receive a ceramic crown. The specimens were randomly divided into 4 groups of 12 specimens each: (1) bilayer crown (zirconium structure with ceramic coating) cemented; (2) bilayer crown (zirconium structure with ceramic coating) without cement; (3) monolithic zirconia crown without cement; (4) cemented monolithic zirconia crown. All groups will be treated as a function of aging, in 2 different times: T1: No aging treatment and stored in a dry place at room temperature; T2: Treatment of artificial aging (hydrothermally), in autoclave, under a humid atmosphere at 131 °C and pressure of 1,7 bar for 5 hours. Marginal adaptation will be evaluated by measuring the absolute marginal discrepancy of the ceramic crowns on the specimens, using a scanning electron microscope. The monoclinic-to-tetragonal (m/t) peak intensity ratio measured by x-ray diffraction was used to calculate the monoclinic phase fraction and monitor LTD. Both zirconia groups showed similar vertical marginal discrepancies, however, no significant differences (p= 0.41) in marginal adaptation were observed among the experimental groups. Moreover, no differences were observed in either group in marginal discrepancies between cementation process neither artificial aging (p= 0.17). The relative XRD peak intensity of the monoclinic to tetragonal phase increased for 1,2 to 3% for bilayer crowns and from 0,8 to 1,6% for monolithic crowns. Monolithic and bilayer CAD /CAM zirconia crowns showed marginal gaps that were within an acceptable range of marginal discrepancy. Cementation was not found to have a statistically significant influence on the marginal fit. Marginal adaptation was not influenced by aging, and this did not lead a significant transformation from tetragonal to monoclinic phase. ?In vitro? studieshave demonstrated that CAD/CAM technology can produce zirconia structures with a clinically acceptable marginal fit. Based on the lack of rigorous scientific longitudinal studies, it seems not clear the relationship between the marginal fit and the resulting degradation of aging.

Page generated in 0.0566 seconds