• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 239
  • 79
  • 37
  • 3
  • Tagged with
  • 361
  • 136
  • 112
  • 57
  • 57
  • 55
  • 49
  • 43
  • 43
  • 42
  • 42
  • 36
  • 33
  • 30
  • 29
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Etudes à haute résolution angulaire de la cinématique des enveloppes proto-stellaires / High angular resolution studies of the kinematics of proto-stellar envelopes

Gaudel, Mathilde 27 November 2018 (has links)
Les étoiles se forment par effondrement gravitationnel de condensations pré-stellaires. Le jeune embryon stellaire (phase Classe 0) croît en masse par l'accrétion progressive de l'enveloppe de gaz et de poussières dans lequel il est enfoui. Par conservation du moment cinétique, si le moment du coeur pré-stellaire est totalement transféré à l'embryon pendant la phase d'accrétion, la force gravitationnelle ne peut contrer la force centrifuge et l'embryon se fragmente prématurément. Pour former une étoile comme notre Soleil, l'enveloppe en rotation doit nécessairement réduire son moment cinétique de 5 à 10 ordres de grandeur en l'évacuant ou en le redistribuant. L'un des principaux défis de la formation stellaire est de quantifier l'ampleur de ce "problème du moment cinétique" et d'identifier les mécanismes responsables de la redistribution du moment.L'objectif de cette thèse est d'étudier la cinématique des enveloppes proto-stellaires de Classe 0 afin d'établir leurs distributions de moment cinétique. Pour cela, j'ai utilisé des observations de raies moléculaires à haute résolution angulaire de l'Interféromètre du Plateau de Bure et du télescope de 30m de l'IRAM issues du large programme CALYPSO (Continuum and Lines in Young Protostellar Objects, PI : Ph. André) pour un échantillon de 12 proto-étoiles de Classe 0 à une distance d<400 pc. Cette analyse a permis de mesurer des mouvements de rotation différentielle et d'établir, pour la première fois, des distributions radiales du moment cinétique spécifique sur une grande gamme d'échelles (~50-10000 au) dans 11 des 12 enveloppes proto-stellaires de l'échantillon. Deux régimes distincts ont ainsi été mis en exergue: un profil constant à petites échelles (<1600 au) et une augmentation du moment avec le rayon aux grandes échelles (1600-10000 au).Le profil constant montre que la matière participant directement à la formation de l'étoile possède un moment cinétique spécifique (~5 10^-4 km/s pc, <1600 au) similaire à celui observé dans les petits disques entourant les étoiles T-Tauri.Les gradients de vitesse observés aux grandes échelles (>3000 au), historiquement utilisés pour mesurer la rotation des coeurs et quantifier le problème du moment cinétique, ne sont pas dus à la pure rotation des enveloppe proto-stellaires, mais sont dominés par d'autres mécanismes. Plusieurs scénarios sont donc discutés pour interpréter le changement de régime dans les profils de moment cinétique aux échelles >1600 au: une empreinte des conditions initiales de la phase pré-stellaire, un changement de mécanismes dominants (contre-rotation, transition effondrement-rotation) ou l'influence de la dynamique des filaments interstellaires (turbulence, effondrement, chocs) dans lesquels les proto-étoiles sont enfouies. / Stars form via the gravitational collapse of a pre-stellar condensation. The young stellar embryo (Class 0 phase) mass increases via the progressive accretion of the gaseous and dusty envelope within which it is buried. As a direct consequence of the angular momentum conservation, if the angular momentum of the pre-stellar core is totally transferred to the central embryo during the accretion phase, the gravitational force can not counteract the centrifugal force and the embryo fragments prematurely before reaching the main sequence. To form a star such as our Sun, the rotating envelope needs to reduce its angular momentum by 5 to 10 orders of magnitude by ejecting or redistributing it. One of the main challenges of stellar formation is to quantify the amplitude of this "angular momentum problem" and identify the mechanisms responsible for the angular momentum redistribution.The goal of this PhD thesis is to study the kinematics of Class 0 protostellar envelopes in order to probe the distribution of their angular momentum. To do this, I used high-resolution observations of molecular lines with the Plateau de Bure Interferometer and the 30m telescope at IRAM taken as part of the large programme CALYPSO (Continuum and Lines in Young Protostellar Objects, PI : Ph. André). The sample gathers 12 Class 0 protostars with distances d<400 pc. This analysis allows to measure differential rotation motions and provides, for the first time in a large sample, robust constraints on the radial distributions of specific angular momentum in a large range of scales (~50-10000 au) for 11 of the 12 protostellar envelopes targeted in the sample. Two distinct regimes are revealed: a constant profile at small scales (<1600 au) and an increasing of the angular momentum at larger radii (1600-10000 au).The constant profile shows that the specific angular momentum (~5 10-4 km/s pc, <1600 au) of the material directly involved in the star formation is similar to the value observed in the small disks surrounding the T-Tauri stars.Velocity gradients observed on large scales (>3000 au) - that are historically used to measure the rotation of the core and quantify the angular momentum problem - are not due to pure envelope rotation but can be dominated by other mechanisms. I discuss several scenarios in order to interpret this change of regime in the angular momentum profiles at scales >1600 au: the imprints of the initial conditions of the pre-stellar phase, a change of dominant mechanisms (counter-rotation, transition between infall and rotation) or the influence of the interstellar filament dynamics (turbulence, collapse, shocks) within which protostars are buried.
172

Le contrôle multiarticulaire et multimusculaire du membre inférieur chez les sujets sains ainsi que chez les sujets ayant une blessure au genou

St-Onge, Nancy January 2002 (has links)
Thèse numérisée par la Direction des bibliothèques de l'Université de Montréal.
173

Modélisation, conception mécanique, étude cinématique et dynamique d'un robot hybride redondant à (6+3) degrés de liberté

Harton, David 24 March 2024 (has links)
Tableau d'honneur de la Faculté des études supérieures et postdoctorales, 2019-2020 / Les robots collaboratifs prennent de plus en plus de place sur les lignes de production au sein des entreprises manufacturières. Leur facilité d'installation et d'utilisation ainsi que leur caractère sécuritaire constituent des avantages liés à leur utilisation. Les robots collaboratifs sériels sont les plus populaires dans l'industrie. Le principal avantage de ceux-ci est leur grand espace de travail. Cependant, l'inertie des architectures sérielles est généralement élevée, limitant ainsi les performances dynamiques du robot. Les robots parallèles sont plus avantageux sur ce point. Un principal avantage des robots parallèles collaboratifs est que les actionneurs sont situés près de la base, diminuant ainsi l'inertie, comparativement aux robot sériels. Cependant il existe peu de robots parallèles collaboratifs sur le marché. Dans ce mémoire est présenté un concept de robot hybride cinématiquement redondant utilisé pour des applications de coopération humain-robot à faible impédance. Ce robot d'architecture 3-[R(RR-RRR)SR] possède (6+3) degrés de liberté (ddl). La redondance du robot permet d'augmenter l'espace du travail notamment en rotation (comparativement à celui d'un robot non redondant d'architecture semblable) en diminuant le nombre de configurations singulières de type II dans l'espace de travail. Le robot est composé de trois jambes d'architecture hybride ayant chacune trois ddl et trois actionneurs ainsi qu'une plateforme composée d'un mécanisme parallèle plan à trois ddl. Les trois degrés de liberté redondants sont utilisés à la plateforme, afin d'y opérer une pince à partir des actionneurs aux jambes. Ce robot possède de grandes capacités en rotation, soient +-90° en inclinaison et en torsion. Ce robot est conçu de manière à ce qu'il soit rétrocommandable et qu'il ait une faible impédance et une faible inertie. Il ne possède aucun réducteur aux actionneurs. Le concept du robot présenté dans ce document est modulaire. En effet, l'architecture des jambes et de la plateforme peuvent différer légèrement afin d'adapter le robot à une application spécifique. Dans le cas présent, des jambes hybrides et une plateforme plane sont choisies pour des fins de simplicité et de maximisation de l'espace de travail. Dans ce document, les modèles cinématiques et dynamiques du robot, de la plateforme et des jambes sont présentés. Les étapes de conception mécanique ainsi qu'une étude de la sensibilité cinématique du robot sont également détaillés. / Collaborative robots become present on production lines in factories. Their easiness of installation and use and their safety features make them more attractive. Serial collaborative robots are the most popular in the industry. Their main advantage is their large workspace. However, the inertia of the members of serial robots is the main limitation of the dynamic performances. Parallel robots are more attractive on this aspect. The main advantage of parallel robots is that their actuators are located near the base, decreasing the inertia compared to serial robots. However, there are few parallel collaborative robots on the market. In this Master's thesis, a novel concept of a redundant hybrid robot used for low impedance physical human-robot interaction (pHRI) applications is presented. This robot has a 3-[R(RRRRR) SR] architecture and (6+3) degrees of freedom (dof). Redundancy allows to get a larger workspace especially in rotation (compared to a non-redundant robot with the same architecture) by avoiding some type II singularity configurations in the workspace. The robot has three 3-dof hybrid legs having three actuators, and the platform, which is a 3-dof parallel planar mechanism. The three redundant degrees of freedom are used at the platform to actuate a gripper from the leg actuators. The robot has a large rotational workspace, namely > +-90° in tilt and torsion. This robot is designed to be backdrivable, with a low impedance and a low inertia. The actuators have no gearbox. The robot presented in this document is modular. Indeed, the leg architecture and the platform may differ depending on the application. In the present case, hybrid legs and planar platform are chosen for simplicity and workspace maximisation purposes. In this document, kinematic and dynamic models of the robot are presented. The main mechanical design steps and a study of the kinetic sensitivity are also detailed.
174

Structures mécaniques à modules sphériques optimisées pour un robot médical de télé-échographie mobile

Al Bassit, Lama 12 July 2005 (has links) (PDF)
A travers la conception de robots porte-sonde ultrasonore pour une application médicale de télééchographie mobile, une étude de conception de structures cinématiques à modules sphériques optimisés est proposée. Le geste médical pendant l'examen d'échographie est analysé ; les résultats sont utilisés pour la définition du cahier des charges concernant la structure cinématique du robot. Une étude de synthèse basée sur les groupes de Lie des déplacements d'un corps rigide est effectuée pour établir un ensemble de mécanismes candidats pour le module de positionnement de translation plane et le module sphérique d'orientation constituant ce robot médical. Une optimisation multicritères sous contraintes est proposée pour les structures sphériques et appliquée sur trois structures : série, parallèle et hybride. La performance cinématique, le volume de l'espace de travail ainsi que des indices exprimant la compacité et la légèreté de la structure interviennent dans l'optimisation. La parcourabilité des structures cinématiques optimisées est étudiée. Les structures cinématiques des robots porte-sonde utilisés dans le système « Otelo » sont présentées.
175

Cinématique tertiaire et rotations de blocs dans l'ouest de l'Asie Centrale (Tien Shan Kirghiz et dépression Tadjik). Etude structurale et paléomagnétique

Thomas, Jean-Charles 10 December 1993 (has links) (PDF)
Depuis 45 Ma, le continent asiatique se déforme sous l'effet de la collision continentale de l'Inde. L'épaississement crustal et l'extrusion de blocs le long de grands décrochements sont considérés comme les deux principaux mécanismes accommodant la déformation. Par ailleurs, des observations structurales suggèrent la présence de rotations de blocs autour d'axes verticaux au niveau des syntaxes Est et Ouest himalayennes et dans une zone allant de l'Afghanistan au Baïkal. L'étude des relations entre épaississement, décrochement et rotations de blocs qui constitue l'objet de ce travail, est un des points importants pour la compréhension de la cinématique Tertiaire de l'Asie. Les mécanismes de déformation et la cinématique T ertiaires de l'Ouest de l'Asie Centrale ont été abordés par le biais du paléomagnétisme et de la géologie structurale. La présente étude a été réalisée dans la dépression Tadjik et le Tien Shan Kirghiz, situés respectivement au nord-ouest et au nord de la syntaxe Ouest- Himalayenne et du Pamir. L'étude paléomagnétique permet de mettre en évidence deux domaines distincts de rotations de part et d'autre de la faille décrochante dextre de Talass-Fergana qui traverse le Tien Shan de part en part. A l'Est de cette faille, les bassins Cénozoïques du Tien Shan présentent une rotation faible ou nulle par rapport à l'Asie stable. A l'inverse, à l'Ouest, les rotations antihoraires sont significatives, de 1'0rdre de 20° dans le bassin de Fergana, de 15 à 50° dans la dépression Tadjik. L'étude structurale montre que le contexte cinématiq ue régional . combine chevauchement et décrochement sénestre. La déformation et la rotation des bassins de type compressifs est principalement localisée dans la couverture sédimentaire, à l'opposé des zones faillées d'échelle crustale qui les limitent. La cinématique Tertiaire du Tien Shan et de la dépression Tadjik apparaît fortement associée au poinçonnement vers le Nord du Pamir par rapport à l'Asie. La faille de Talass-Fergana est une discontinuité majeure à l'Ouest de laquelle la déformation est accommodée par de l'épaississement, du décrochement et des rotations de blocs.
176

Analyse cinématique 3D de la coordination des articulations de l'épaule par l'entremise du rythme scapulo-huméral

Robert-Lachaîne, Xavier 07 1900 (has links)
L'épaule est souvent affectée par des troubles musculo-squelettiques. Toutefois, leur évaluation est limitée à des mesures qualitatives qui nuisent à la spécificité et justesse du diagnostic. L'analyse de mouvement tridimensionnel pourrait complémenter le traitement conventionnel à l'aide de mesures quantitatives fonctionnelles. L'interaction entre les articulations de l'épaule est estimée par le rythme scapulo-huméral, mais la variabilité prononcée qu'il affiche nuit à son utilisation clinique. Ainsi, l'objectif général de cette thèse était de réduire la variabilité de la mesure du rythme scapulo-huméral. L'effet de la méthode de calcul du rythme scapulo-huméral et des conditions d'exécution du mouvement (rotation axiale du bras, charge, vitesse, activité musculaire) ont été testées. La cinématique des articulations de l'épaule a été calculé par chaîne cinématique et filtre de Kalman étendu sur des sujets sains avec un système optoélectronique. La méthode usuelle de calcul du rythme scapulo-huméral extrait les angles d'élévation gléno-humérale et de rotation latérale scapulo-thoracique. Puisque ces angles ne sont pas co-planaires au thorax, leur somme ne correspond pas à l'angle d'élévation du bras. Une nouvelle approche de contribution articulaire incluant toutes les rotations de chaque articulation est proposée et comparée à la méthode usuelle. La méthode usuelle surestimait systématiquement la contribution gléno-humérale par rapport à la méthode proposée. Ce nouveau calcul du rythme scapulo-huméral permet une évaluation fonctionnelle dynamique de l'épaule et réduit la variabilité inter-sujets. La comparaison d'exercices de réadaptation du supra-épineux contrastant la rotation axiale du bras a été réalisée, ainsi que l'effet d'ajouter une charge externe. L'exercice «full-can» augmentait le rythme scapulo-huméral et la contribution gléno-humérale ce qui concorde avec la fonction du supra-épineux. Au contraire, l'exercice «empty-can» augmentait la contribution scapulo-thoracique ce qui est associé à une compensation pour éviter la contribution gléno-humérale. L'utilisation de charge externe lors de la réadaptation du supra-épineux semble justifiée par un rythme scapulo-huméral similaire et une élévation gléno-humérale supérieure. Le mouvement de l'épaule est souvent mesuré ou évalué en condition statique ou dynamique et passive ou active. Cependant, l'effet de ces conditions sur la coordination articulaire demeure incertain. La comparaison des ces conditions révélait des différences significatives qui montrent l'importance de considérer les conditions de mouvement pour l'acquisition ou la comparaison des données. / The shoulder is often afflicted by musculo-skeletal diseases. However, shoulder evaluation is limited to qualitative measures affecting the specificity and accuracy of diagnosis. Three-dimensional motion analysis could complement conventional treatment with quantitative functional measures. The interaction between shoulder joints is estimated by the scapulo-humeral rhythm, but its pronounced variability of measurement ampers appropriate clinical use. Hence, the main objective of the thesis was to reduce the variability in the measure of the scapulo-humeral rhythm. The effect of the calculation method and conditions of motion (arm axial rotation, load, velocity, muscular activity) were tested on healthy subjects. Shoulder joints kinematics were obtained with an optoelectronic system using a kinematical chain and an extended Kalman filter. The common method of scapulo-humeral rhythm calculation extracts the angles of gleno-humeral elevation and scapulo-thoracic lateral rotation. Since these angles are not co-planar, their sum does not correspond to the arm elevation angle. A novel approach of joint contribution including all the rotations of each joint was developed and compared to the common method. The common method systematically overestimated gleno-humeral contribution in comparison to the proposed method. The new scapulo-humeral rhythm calculation allows a dynamic functional evaluation of the shoulder and reduces inter-subject variability. Shoulder coordination was compared on typical supraspinatus rehabilitation exercises contrasting in arm axial rotation, and the effect of adding external load was tested. The ''full-can'' exercise increased the scapulo-humeral rhythm and gleno-humeral contribution, which correspond to supraspinatus function. In contrast, the ''empty-can'' exercise increased scapulo-thoracic contribution, which is associated to compensation to avoid gleno-humeral contribution. The use of external load in supraspinatus rehabilitation seems justified by a similar scapulo-humeral rhythm and superior gleno-humeral elevation. Shoulder motion is often measured or evaluated in static or dynamic and passive or active conditions. However, the effect of these conditions on shoulder coordination remains uncertain. The comparison of these conditions revealed significant differences on shoulder kinematics showing the importance to consider conditions of motion for acquisition or comparison of data.
177

Évaluation clinique et biomécanique de deux différents types d’arthroplastie totale de genou

Renaud, Alexandre 11 1900 (has links)
Différents dessins d’implants de prothèse totale de genou (PTG) sont utilisés en pratique clinique et chacun présente des caractéristiques biomécaniques spécifiques. Aucun implant n’a réussi à ce jour à reproduire parfaitement la biomécanique du genou naturel. Les objectifs de cette étude sont de comparer les résultats cliniques et biomécaniques tridimensionnels (3D) de deux types de PTG chez le même patient, puis de comparer la cinématique des PTG à celle d’un groupe de genoux asymptomatiques. Une cohorte de quinze patients avec un implant traditionnel dans un genou et un implant de nouvelle génération permettant un pivot dans le genou contralatéral a été étudiée. Le groupe contrôle était composé de trente-cinq genoux asymptomatiques. L’analyse de la cinématique 3D a été réalisée avec l’outil KneeKG (Emovi Inc. Canada) lors de la marche sur tapis roulant. L’évaluation clinique comprenait l’amplitude de mouvement ainsi que les questionnaires de perception articulaire, KOOS, Womac et SF-12. La comparaison de la cinématique des deux types de PTG a démontré quelques différences statistiquement significatives dans les plans sagittal et frontal alors que la comparaison des PTG et des genoux asymptomatiques a révélé plusieurs différences significatives dans les trois plans. Les scores cliniques des deux PTG ne comportaient pas de différence significative. Dans notre cohorte de patients, le design de l’implant a eu peu d’influence sur les résultats biomécaniques et cliniques. Les PTG n’ont pas reproduit une cinématique normale de genou. Beaucoup de travail et de recherche dans le développement de nouveaux implants sont encore nécessaires afin d’améliorer les résultats cliniques et de mieux reproduire la cinématique du genou naturel. / Various implants of total knee arthroplasty (TKA) are used in clinical practice and each presents specific biomechanical characteristics. No implant managed this day to reproduce perfectly the biomechanics of the natural knee. The objectives of this study are to compare the clinical and tridimensional (3D) biomechanical data of two different designs of TKA on the same patients and to compare the resulting 3D biomechanical data with those of asymptomatic knees. A cohort of fifteen patients with a traditional implant in one knee and an implant of new generation allowing a pivot in the contralateral knee was studied. The control group was composed of thirty-five asymptomatic knees. Assessment of 3D knee kinematics analysis was realized with the KneeKG (Emovi Inc. Canada) during treadmill gait. Clinical evaluation included range of motion as well as questionnaires of joint perception, KOOS, Womac and SF-12. Results showed some statistically significant differences in knee 3D kinematics of both TKAs in sagittal and frontal planes while comparison between TKAs and asymptomatic knees revealed several significant differences in all three planes. Clinical scores of both TKAs did not have significant difference. In our cohort of patients, TKA implant design had few measurable influences on kinematics during gait and on clinical results. TKA with these implants did not reproduce natural knee kinematics during gait. Significant research and development in new TKA designs are needed to improve clinical scores and reproduce natural knee kinematics.
178

Contrôle moléculaire de la croissance sous déficit hydrique : analyse cinématique et régulation de l'expression des aquaporines TIP1 dans l'apex de la racine du peuplier / Molecular control of growth under water deficit : kinematic analysis and regulation of expression of TIP1 aquaporins in the poplar root apex

Merret, Rémy 10 November 2010 (has links)
Cette étude porte sur le contrôle moléculaire de l'expansion cellulaire dans l'apex de la racine du peuplier. L'étude a été focalisée sur la régulation de l'expression des aquaporines TIP1s sous deux niveaux de déficit hydrique. Un cadre conceptuel, combinant analyse de la densité de transcrits à haute résolution spatiale et un formalisme de la mécanique des fluides, a été établi pour décrire la régulation de l'expression des gènes dans le temps et l'espace, le long de l'apex. Deux états de croissance contrastés ont été étudiés : un où la croissance de l'apex de la racine est rétablie (après 3 jours de stress modéré, 80 mosmol kg-1, 100 g L-1 de polyéthylène glycol PEG à 3500 g mol-1) et un où elle est réduite (après 3 jours de stress fort, 250 mosmol kg-1, 200 g L-1 de PEG). L'analyse cinématique a révélé une sensibilité différentielle de la vitesse d'allongement relatif (REGR) selon le niveau de stress et la position le long de l'apex. Au niveau moléculaire, nous montrons que lorsque la croissance est réduite, les pics de densité de transcrits des TIP1s sont plus forts et décalés dans les premiers millimètres de l'apex, zone où la croissance des cellules est maintenue. Cependant les niveaux d'induction/répression n'étaient jamais plus élevés que dans la condition témoin, soulignant qu'une forte densité de transcrits n'est pas forcément synonyme d'une forte induction de l'expression. Focalisé sur la combinaison de deux processus dynamiques, l'expansion cellulaire et l'expression des gènes, cette étude a mis en évidence que les conclusions tirées de l'analyse de ces processus sont influencées par la façon dont le temps, l'espace sont considérés / This study consideres the molecular control of cell expansion in poplar root apex. The study was focused on the regulation of the TIP1 aquaporins expression under two levels of water deficit. A conceptual framework combining transcript density analysis (quantitative PCR) at a high spatial resolution and a fluid mechanics formalism was established to describe the regulation of gene expression in time and space along the root apex. Two contrasting growth status were both studied: root growth rate is either restored (after three days of moderate stress, 80 mmol kg-1, 100 g L-1 polyethylene glycol PEG 3500 g mol-1) or root growth rate is reduced (after 3 days of high stress, 250 mosmol kg-1, 200 g L-1 PEG). Kinematic analysis revealed a differential sensitivity of the relative elemental growth rate (REGR) according to the stress level and to the coordinate along the apex. At the molecular level, we showed that growth reduction was associated with a shift of maximal densities of transcripts towards the first millimeters of the apex, where cell expansion was maintained. Meanwhile the induction/repression levels were never stronger than in the control condition underlying that a high transcript density does not mean a high transcriptional induction. Focused on the combination of two dynamic processes, cell expansion and gene expression, my thesis showed that the conclusions issued from the analyses of these processes are influenced by the way time, space and age are considered
179

Méthode numérique d'estimation du mouvement des masses molles

Thouzé, Arsène 10 1900 (has links)
L’analyse biomécanique du mouvement humain en utilisant des systèmes optoélectroniques et des marqueurs cutanés considère les segments du corps comme des corps rigides. Cependant, le mouvement des tissus mous par rapport à l'os, c’est à dire les muscles et le tissu adipeux, provoque le déplacement des marqueurs. Ce déplacement est le fait de deux composantes, une composante propre correspondant au mouvement aléatoire de chaque marqueur et une composante à l’unisson provoquant le déplacement commun des marqueurs cutanés lié au mouvement des masses sous-jacentes. Si nombre d’études visent à minimiser ces déplacements, des simulations ont montré que le mouvement des masses molles réduit la dynamique articulaire. Cette observation est faite uniquement par la simulation, car il n'existe pas de méthodes capables de dissocier la cinématique des masses molles de celle de l’os. L’objectif principal de cette thèse consiste à développer une méthode numérique capable de distinguer ces deux cinématiques. Le premier objectif était d'évaluer une méthode d'optimisation locale pour estimer le mouvement des masses molles par rapport à l’humérus obtenu avec une tige intra-corticale vissée chez trois sujets. Les résultats montrent que l'optimisation locale sous-estime de 50% le déplacement des marqueurs et qu’elle conduit à un classement de marqueurs différents en fonction de leur déplacement. La limite de cette méthode vient du fait qu'elle ne tient pas compte de l’ensemble des composantes du mouvement des tissus mous, notamment la composante en unisson. Le second objectif était de développer une méthode numérique qui considère toutes les composantes du mouvement des tissus mous. Plus précisément, cette méthode devait fournir une cinématique similaire et une plus grande estimation du déplacement des marqueurs par rapport aux méthodes classiques et dissocier ces composantes. Le membre inférieur est modélisé avec une chaine cinématique de 10 degrés de liberté reconstruite par optimisation globale en utilisant seulement les marqueurs placés sur le pelvis et la face médiale du tibia. L’estimation de la cinématique sans considérer les marqueurs placés sur la cuisse et le mollet permet d'éviter l’influence de leur déplacement sur la reconstruction du modèle cinématique. Cette méthode testée sur 13 sujets lors de sauts a obtenu jusqu’à 2,1 fois plus de déplacement des marqueurs en fonction de la méthode considérée en assurant des cinématiques similaires. Une approche vectorielle a montré que le déplacement des marqueurs est surtout dû à la composante à l’unisson. Une approche matricielle associant l’optimisation locale à la chaine cinématique a montré que les masses molles se déplacent principalement autour de l'axe longitudinal et le long de l'axe antéro-postérieur de l'os. L'originalité de cette thèse est de dissocier numériquement la cinématique os de celle des masses molles et les composantes de ce mouvement. Les méthodes développées dans cette thèse augmentent les connaissances sur le mouvement des masses molles et permettent d’envisager l’étude de leur effet sur la dynamique articulaire. / Biomechanical analysis of human movement using optoelectronic system and skin markers considers body segments as rigid bodies. However the soft tissue motion relative to the bone, including muscles, fat mass, results in relative displacement of markers. This displacement is the results of two components, an own component which corresponds to a random motion of each marker and an in-unison component corresponding to the common movement of skin markers resulting from the movement of the underlying wobbling mass. While most studies aim to minimize these displacements, computer simulation models have shown that the movement of the soft tissue motion relative to the bones reduces the joint kinetics. This observation is only available using computer simulations because there are no methods able to distinguish the kinematics of wobbling mass of the bones kinematics. The main objective of this thesis is to develop a numerical method able to distinguish this different kinematics. The first aim of this thesis was to assess a local optimisation method for estimating the soft tissue motion using intra-cortical pins screwed into the humerus in three subjects. The results show that local optimisation underestimates of 50% the marker displacements. Also it leads to a different marker ranking in terms of displacement. The limit of local optimisation comes from the fact that it does not consider all the components of the soft tissue motion, especially the in-unison component. The second aim of this thesis was to develop a numerical method that accounts for all the component of the soft tissue motion. More specifically, this method should provide similar kinematics and estimate large marker displacement and distinguish the two components to conventional approaches. The lower limb is modeled using a 10 degree of freedom chain model reconstructed using global optimisation and the markers placed only on the pelvis and the medial face of the shank. The original estimate of joint kinematics without considering the markers placed on the thigh and on the calf avoids the influences of these markers displacement on the kinematic model reconstruction. This method was tested on 13 subjects who performed hopping trials and obtained up to 2.1 times of marker displacement depending the method considered ensuring similar joint-kinematics. A vector approach shown that marker displacements is more induce by the in-unison component. A matrix approach combining the local optimisation and the kinematic model shown that the wobbling mass moves around the longitudinal axis and along the antero-posterior axis of the bone. The originality of this thesis is to numerically distinguish the bone kinematics from the wobbling mass kinematics and the two components of the soft tissue motion. The methods developed in this thesis increases the knowledge on soft tissue motion and allow future studies to consider their movement in joint kinetics calculation.
180

L’effet de la prothèse totale du genou sur la cinématique 3D : vers le développement de biomarqueurs mécaniques de la douleur

Larose, Gabriel 06 1900 (has links)
La prothèse totale du genou (PTG) est une chirurgie couramment pratiquée pour traiter les patients souffrant d’arthrose sévère du genou. Bien que cette technique chirurgicale soit efficace pour diminuer la douleur, améliorer la fonction du genou et rentable d’un point de vue socio-économique, un pourcentage non négligeable de patients n’est pas satisfait suite à la chirurgie, principalement due à une douleur persistante ou due à une perception d’avoir une mauvaise fonction articulaire, sans cause identifiée. Cependant, l’impact de cette chirurgie sur la cinématique tridimensionnelle (3D) du genou demeure mal compris. Dans le but de mieux comprendre pourquoi certains patients ressentent toujours de la douleur suite à cette chirurgie, cette étude analysera, dans un premier temps, l’effet prospectif de la chirurgie sur la cinématique 3D du genou. Puis dans un second temps, comparera la cinématique 3D de sujet souffrant de douleur à celle de sujets asymptomatiques suite à la prothèse. Pour parvenir à ces deux objectifs, deux études distinctes ont été entreprises. Une première étude prospective a porté sur l’évolution de la cinématique 3D du genou d’un groupe de 19 sujets, recrutés sur la liste d’attente pour prothèse totale du genou de deux chirurgiens du CHUM, hôpital Notre-Dame, puis la cinématique a été comparée avec un groupe contrôle de 17 sujets avec des genoux sains. Une seconde étude a comparé la cinématique 3D de 20 sujets souffrant de douleur post-PTG avec 20 sujets avec des genoux asymptomatiques suite à leur chirurgie. La première étude a permis de montrer que la cinématique dans le plan frontal suite à la prothèse totale du genou était corrigée vers celle des sujets sains. Contrairement à celle mesurée dans les autres plans (sagittal et axial) qui, malgré de petites corrections, demeure différente de la cinématique des sujets sains. La seconde étude a permis d’identifier un marqueur biomécanique de la douleur chez les sujets souffrant de douleur post-PTG. Effectivement, contrairement aux sujets asymptomatiques, suite à leur chirurgie, les patients souffrants de douleur marchent avec une contracture en flexion plus importante tout au long de la phase d’appui. Les résultats de ces deux études tendent à montrer que la prothèse totale du genou modifie la cinématique 3D du genou, sans toutefois redevenir semblable à celle d’un genou normal. De plus, certains marqueurs biomécaniques peuvent être associés à de la douleur suite à la chirurgie. Une meilleure compréhension de l’impact de la PTG sur la cinématique 3D du genou permettra d’offrir de meilleurs traitements en préparation et après la chirurgie et pourrait mener à de nouveaux designs de prothèses. / The total knee arthroplasty (TKA) is a common procedure in patients with severe knee osteoarthritis. This surgery has been proved to reduce pain, to improve knee function, and to be cost-effective. However, an important proportion of patients report insatisfaction, pain, and low articular function following the surgery. Moreover, even with this problem, the impact of the TKA on the tridimensional (3D) kinematics is not well understood. Therefore, two studies have been undertaken with the purpose of using the 3D kinematics to understand the post-TKA pain syndrome. During the first study, 19 subjects, recruited on a TKA waiting list of two surgeons of the CHUM, Hôpital Notre-Dame, were prospectively followed to measure the evolution of their 3D knee kinematics. A control group of 17 subjects with normal knees has also been recruited. The second study has compared 20 subjects with knee pain post-TKA with 20 subjects without pain post-TKA. The results of the first study tend to show an improvement in the frontal plan kinematics after the TKA toward the control group. However, the kinematics in the others plans still different of the control group. When the 3D kinematics of a group with pain is compared to a group without pain (second study), a biomechanical marker associated with pain was identified. The group with pain walk with a higher flexion contracture during the stance phase than the group without pain. Those results show that the total knee arthroplasty has an impact on the 3D kinematics; however, this impact is not necessarily toward the control group. Moreover, some biomechanical markers can be associated with the knee pain following the TKA. This show that we still doesn’t really understand the impact of the TKA on the kinematics, and that a better understanding of this impact could allow the surgeons to improve their care to their patients before and after the surgery.

Page generated in 0.0731 seconds