• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 751
  • 16
  • 16
  • 16
  • 16
  • 11
  • 9
  • 5
  • 5
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 770
  • 437
  • 309
  • 299
  • 212
  • 146
  • 87
  • 79
  • 76
  • 76
  • 67
  • 63
  • 61
  • 60
  • 60
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
611

Evolução estrutural dos granitoides arroio divisa durante o movimento transcorrente da zona de cisalhamento Quitéria-Serra do Erval, RS

Schnorr, Evelin Roberta January 2017 (has links)
O período pós-colisional Neoproterozoico no sul do Brasil é marcado por intensa atividade tectônica transcorrente. Neste contexto, a Zona de Cisalhamento Quitéria Serra do Erval, uma das inúmeras estruturas que compõe o Cinturão de Cisalhamento Sul-brasileiro, controlou o aporte, a ascensão e o posicionamento de diversos granitoides, dentre eles, os Granitoides Arroio Divisa, intrusivos no Complexo Arroio dos Ratos. Os Granitoides Arroio Divisa compreendem uma associação de rochas predominantemente granodioríticas, com termos dioríticos e tonalíticos ocorrendo em menor expressão. Apresentam textura heterogranular média a grossa e são sempre foliadas. Ao longo da intrusão, são distinguidas zonas de mais alta e mais baixa deformação, distribuídas de forma heterogênea, o que é evidenciado pelo grau de desenvolvimento e morfologia das estruturas planares e lineares. Nas zonas de mais baixa deformação, concentradas nas porções centrais do corpo granítico, predominam as estruturas magmáticas e a componente deformacional é menos intensa, enquanto que em direção à borda norte da intrusão, a morfologia destas estruturas progride por aumento na intensidade da deformação, com a geração de foliação milonítica bem desenvolvida A evolução estrutural dos Granitoides Arroio Divisa é marcada por estruturas tardi-magmáticas que avançam progressivamente para estruturas subsolidus, e subsequentemente para estruturas de mais baixa temperatura, evidenciando a cristalização com concomitante história deformacional sob condições de temperatura decrescente. Feições microestruturais de alta temperatura incluem o desenvolvimento do padrão tabuleiro de xadrez em cristais de quartzo, e a geração de subgrãos grandes em cristais de K-feldspato e plagioclásio, compatíveis com temperaturas da fácies anfibolito superior e com a temperatura solidus de composições graníticas. As feições microestruturais de baixa temperatura consistem na recristalização dos cristais de quartzo por bulging, neoformação de grãos finos ao redor dos cristais de feldspato, e desenvolvimento de pertitas em chamas nos K-feldspato, compatíveis com temperaturas da fácies xistos verdes, bem abaixo da solidus. Enquanto as microestruturas de alta deformação estariam associadas aos estágios iniciais da cristalização e resfriamento do magma, as de mais baixa estariam relacionadas aos estágios pós-cristalização, quando rocha e encaixante alcançam equilíbrio térmico. / The Neoproterozoic post-collisional period in southern Brazil is marked by intense transcurrent tectonic activity. In this context, the Serra do Erval Quitéria Shear Zone, one of the several structures that compose the South Brazilian Shear Belt, controlled the input, ascent and emplacement of several granitoids, among them the Arroio Divisa Granitoids, intrusive in the Complex Arroio dos Ratos. The Arroio Divisa Granitoids consist an association of predominantly granodioritic rocks, with dioritic and tonalitic terms occurring in lesser expression. They presented medium to thick heterogranular texture and are always foliated. Along the intrusion, zones of higher and lower deformation are distinguished, distributed in a heterogeneous way, which is evidenced by the degree of development and morphology of the planar and linear structures. In the lower deformation zones, which are concentrated in the central portion of the granitic body, the magmatic structures prevail and the deformation component is less intense, whereas towards the north margin of the intrusion the morphology of these structures progresses by increase in the intensity of the deformation, with the generation of well-developed milonitic foliation The structural evolution of the Arroio Divisa Granitoids is marked by progressively advance of the late-magmatic to subsolidus structures, and subsequently to structures of lower temperature, evidencing the crystallization with concomitant deformational history under conditions of decreasing temperature. High-temperature microstructural features include the development of the chessboard pattern in quartz crystals, and the generation of large subgrains in K-feldspar and plagioclase crystals, compatible with temperatures of amphibolite high-grade facies and with the solidus temperature of granite compositions. The low temperature microstructural features consist of recrystallization of the quartz crystals by bulging, neoformation of fine grains around the feldspar crystals, and development of flaming pertite in the K-feldspar, compatible with temperatures of the greenschist facies, well below the solidus. While the high deformation microstructures would be associated to the initial stages of crystallization and cooling of the magma, the one of lower deformation would be associated to the post crystallization stages, when rock and host rock reach thermal balance.
612

Efeito da radioterapia na adesão e interface ao substrato de dentes permanentes / Effect of radiotherapy on bonding and bonding interface to substrate of permanent teeth

Juliana Arid 27 November 2015 (has links)
O câncer de cabeça e pescoço é, dentre todos os tipos de cânceres, o sétimo mais comum, dentre suas principais formas de tratamento está a radioterapia (RT), que é amplamente utilizada e eficiente, mas os efeitos colaterais aos tecidos adjacentes são inevitáveis. A realização do tratamento odontológico previamente a radioterapia é de suma importância e visa eliminar/reduzir os focos infecciosos presentes na cavidade bucal, sendo essencial a eliminação das lesões de cárie, e após a radioterapia é fundamental tratar as \"cáries de radiação\", que é um dos efeitos colaterais do tratamento radioterápico de cabeça e pescoço. Os sistemas resinosos são os materiais mais indicados para restauração dos dentes de pacientes submetidos à radioterapia, por isso o objetivo do presente estudo foi avaliar in vitro o efeito da radiação, no momento em que é realizada a restauração ao esmalte e a dentina, por meio de teste de cisalhamento, analisar longitudinalmente as alterações morfológicas na superfície do substrato dental durante a radiação por meio de microscopia confocal a laser e analisar qualitativamente a interface de união compósito/substrato dental por meio de microscopia eletrônica de varredura (MEV). Foram utilizados 60 terceiros molares permanentes, que foram seccionados em um total de 120 fragmentos de esmalte e 120 de dentina, e após o preparo da superfície foram divididos aleatoriamente em grupos 4 grupos (n=30): G1 (controle) - substrato sem irradiação + procedimento restaurador; G2 - procedimento restaurador realizado antes da RT; G3 - procedimento restaurador realizado após a RT; e G4 - procedimento restaurador realizado 6 meses após a RT. Cada um dos grupos foi dividido em 2 subgrupos, sendo empregado no subgrupo \"A\" (SGA) o adesivo AdperTM Single Bond 2 (SB); e no subgrupo \"B\" (SGB) o adesivo Clearfil SE Bond (CL), para o procedimento restaurador. Os espécimes foram irradiados com fração de dose de 2Gy, 5 dias consecutivos, até atingirem a dose total de 60Gy, com um total de 30 frações, durante 6 semanas. O procedimento restaurador foi realizado com resina Z350, e para padronização da restauração foi utilizada uma matriz, de forma que os espécimes apresentam 4mm de altura e 2mm de diâmetro. Os corpos de prova foram submetidos ao teste de resistência ao cisalhamento e depois analisou-se o modo de fratura. Foram selecionados 5 espécimes de cada substrato, para a realização da análise morfológica da superfície dental por meio da microscopia confocal, sendo estes avaliados a cada 10Gy. Para a análise da interface adesiva foram selecionados 3 espécimes de cada grupo e estes foram preparados para realização da MEV. O sistema adesivo CL apresentou desempenho superior, em ambos substratos, quando comparado o SB; quanto ao tempo da restauração, tanto em esmalte quanto em dentina, o grupo 2 apresentou os menores valores; o padrão de fratura predominante para todos os grupos foi a Adesiva; houveram alterações morfológicas notáveis em esmalte e dentina após a dose acumulativa de 30Gy, onde aos 60Gy, no esmalte, os prismas se tornaram amorfos e a camada interprismática degradada, e na dentina os túbulos dentinários encontravam-se completamente obliterados; na análise da interface adesiva do grupo 2 notou-se que quase não houve formação de tags e nos grupos 3 de esmalte a camada adesiva formada era mais fina, porém com formação de tags mais prolongados e na dentina houve formação de gaps. / Head and neck cancer is among all kinds of cancer the seventh most common and radiotherapy (RT) is one of its main treatments, which is widely used and efficient, but side effects are unavoidable. A dental treatment before RT is very important to reduce/eliminate infectious foci in the oral cavity, so it is essential to eliminate carious lesions, and after RT \"radiation caries\", which are a side effect of the treatment, must be eliminated. Adhesive systems are the most indicated to restore teeth of patients undergoing RT, so this study aimed to evaluate in vitro the effect of RT in the moment of the dental restorations in enamel and dentin, using shear bond strength tests, evaluate morphologic alterations at teeth surface during RT, with a laser confocal microscopy and to evaluate qualitatively the union interface of the composite/ dental substrate by scanning electron microscope (SEM). It was used 60 third molars, which were sectioned into 120 fragments of enamel and 120 of dentin, and after the surface prepare the specimens were randomly divided into 4 groups (n=30): G1 (control) - no irradiated substrate + restorative procedure; G2 - restorative procedure performed before RT; G3 - restorative procedure performed after RT; e G4 - restorative procedure performed 6 months after RT. Each group was divided into 2 subgroups: Subgroup \"A\" (SGA) in which was used the AdperTM Single Bond 2 (SB); and subgrup \"B\" in which was used Clearfil SE Bond (CL), for the restorative procedure. The specimens were fractionally irradiated by a dose of 2Gy/day, 5 consecutive days, until it reached a total dose of 60Gy, in a total of 30 fractions, lasting 6 weeks. For the restorative treatment the resin Z350 was chosen, and for standardization it was used a matrix so all specimens had 4mm height and 2mm in diameter. The specimens were submitted to shear bond strength test and the fracture pattern was evaluated. It was chosen 5 specimens of each substrate for the morfological evaluation of the dental surface by a laser confocal microscopy, those were evaluate every 10Gy. To evaluate the adhesive interface it was chosen 3 specimens of each group and those were prepared for the SEM. A better performance was observed for the CL, in both dental substrates, rather than the SB; according to the period of restoration, in both enamel and dentin, Group 2 has showed lower values; the predominant fracture pattern to all groups was the Adesive one; there were morphological alterations in enamel and dentin after a cumulative dose of 30Gy, the prisms of enamel became formless and the interprismatic region was degraded after 60Gy, at the dentin the dental tubules were completely amorphous; the analysis of the interface adhesion has showed that in group 2 tags were barely formed, and in group 3 of enamel the adhesive layer was thinner, but tags were longer, and at the dentin gaps were observed.
613

Propriedades física e adesiva do esmalte dental após radioterapia e colagem de bráquetes ortodônticos / Physical and adhesive properties of dental enamel after radiotherapy and bonding orthodontic brackets

Gabriela Cristina Santin 01 December 2014 (has links)
O objetivo deste trabalho foi avaliar as propriedades físicas e adesivas do esmalte dental após radioterapia e colagem de bráquetes ortodônticos metálicos e cerâmicos. O estudo foi dividido em duas etapas. Na primeira, foram utilizados 10 molares permanentes humanos hígidos, que foram seccionados em fragmentos de esmalte de 1 mm² e divididos entre grupo irradiado e não irradiado, de forma pareada. O grupo irradiado foi submetido à radiação ionizante, com uma dose total de 60 Gy, 2 Gy/dia, durante seis semanas, com intervalo de dois dias entre às semana. Os fragmentos de esmalte dental foram submetidos a teste mecânicos de microcisalhamento para verificar se a radioterapia alterou a resistência coesiva do esmalte dental irradiado. A segunda etapa deste estudo utilizou-se de 90 pré-molares humanos hígidos e devidamente preparados, divididos em seis grupos/subgrupos (n=15): G1 - dentes não irradiados e não envelhecidos; G2 - dentes não irradiados e envelhecidos; G3 - dentes irradiados e envelhecidos; Subgrupos: bráquetes metálicos (M) e bráquetes cerâmicos (C). Os grupos G2 e G3 foram submetidos à envelhecimento artificial acelerado por meio de termociclagem, simulando o período aproximado de 1 a 2 anos, tempo esse indicado para o início de tratamento ortodôntico em pacientes pós radioterapia. Em seguida, os grupos G2 e G3 foram submetidos à radioterapia, conforme descrito. Finalizado o ciclo radioterápico, os bráquetes foram colados no esmalte dental dos espécimes com compósito Transbond XT, sendo o bráquete metálico Morelli e cerâmico Radiance. Após 24 horas, os corpos de prova foram submetidos à teste mecânico de cisalhamento e a superfície do esmalte avaliada em microscopia confocal de varredura à laser (MCVL) avaliando o índice de remanescente adesivo (IRA) e modo de fratura. Em seguida, quatro corpos de prova que apresentaram fratura do tipo coesiva de cada grupo/subgrupos foram devidamente preparados e a interface compósito/esmalte avaliada em MCVL e microscopia eletrônica de varredura. Os fragmentos de esmalte dental submetidos à radiação apresentaram menores valores de resistência ao cisalhamento do que o esmalte dental não irradiado (p<0,05). Levando em consideração a interação dos fatores dos espécimes submetidos ao teste de cisalhamento, os grupo/subgrupos submetidos à radiação e colados bráquetes cerâmicos, apresentaram menores valores de resistência. Os grupos não submetidos à irradiação, G1-M e G2-M, apresentaram com maior frequência IRA escore 0 (sem compósito na superfície), enquanto, os grupos G1-C, G2-C, G3-M e G3-C apresentaram mais de 50% de compósito aderido à superfície Quanto ao modo de fratura, os grupos controle apresentaram em sua maioria os tipos de fratura adesiva (Ad) e coesiva resina (CR), independente do tipo de bráquete Os bráquetes metálicos colados em esmalte dental submetidos à irradiação apresentaram fratura do tipo mista coesiva resina/adesiva (CR/Ad), enquanto os bráquetes cerâmicos resultaram em fraturas coesiva resina (CR) e coesiva resina/adesiva (CR/Ad). Nas imagens obtidas da região de interface compósito/esmalte, observou-se que os tags de resina foram mais extensos no esmalte dental irradiado, circundando os prismas de esmalte. Assim, conclui-se que a radiação diminuiu a resistência coesiva do esmalte dental e que os espécimes submetidos à radioterapia apresentaram maior falha adesiva entre bráquete/compósito e tags de resina mais extensos e profundos quando comparados ao grupo controle / The objective of this study was to evaluate the physical and adhesive properties of the enamel after radiotherapy and bonding of metal and ceramic orthodontic brackets. The study was divided into two stages. In the first one, 10 human permanent molars, which were cut into fragments of enamel 1 mm² and divided between irradiated and non-irradiated group, in a paired form. The irradiated group was subjected to ionizing radiation, with a total dose of 60 Gy, 2 Gy / day for six weeks, with an interval of two days between the weeks. The enamel fragments were subjected to mechanical testing to verify that microshear radiotherapy changed cohesive strength of the irradiated enamel. In The second phase of this study, was used 90 healthy and properly prepared human premolars,divided into six groups / subgroups (n = 15): G1 - non-irradiated teeth and not aged; G2 teeth unirradiated and aged; G3 - irradiated and aged teeth; Subgroups: metallic brackets (M) and ceramic brackets (C). G2 and G3 were subjected to accelerated artificial aging by thermal cycling, simulating period of approximately 1 to 2 years, this time indicated for the beginning of orthodontic treatment in post radiotherapy patients. Then the G2 and G3 groups underwent radiotherapy as described. After the radiotherapy cycle, the brackets were bonded on the enamel specimens with Transbond XT, and the metallic and Morelli ceramic bracket Radiance. After 24 hours, the specimens were subjected to mechanical shear test and evaluated the enamel surface in confocal laser scanning microscopy (CLSM) evaluating the adhesive remnant index (ARI) and fracture mode. Then four specimens showed that the cohesive fracture type were properly prepared for each group / subgroup and the composite interface / enamel evaluated CLSM and scanning electron microscopy. Fragments enamel subjected to radiation had significantly lower shear strength than the non-irradiated enamel (p <0.05). Considering the interaction of the factors of the specimens subjected to shear stress, the group / subgroup undergoing radiation and bonded ceramic brackets showed lower resistance values. The two groups were subjected to irradiation, G1 and G2-M-M, showed more IRA frequency scores of 0 (no composite surface), while the C-G1, G2, C, G3 and G3-M-C groups had more 50% of adhesive left on the surface Concerning the fracture mode, the control groups showed mostly the types of adhesive fracture (Ad) and cohesive resin (CR), regardless of the bracket\'s metal brackets bonded submitted to enamel irradiation, that showed mixed type of cohesive resin / adhesive (CR / Ad) fracture, while ceramic brackets resulted in cohesive fractures resin (CR) and cohesive resin / adhesive (CR / Ad). In images obtained from the composite region / enamel interface, it was observed that the resin tags were more extensive in the irradiated tooth enamel surrounding the enamel prisms. Thus, it is concluded that radiation decreased the tensile strength of the enamel and the specimens treated with radiotherapy had higher adhesive failure between bracket / composite and tags of more extensive and deep resin, compared to the control group
614

Resistência ao cisalhamento de selante associado a dois sistemas adesivos, após contaminação salivar: influência da fotopolimerização individual e simultânea / Shear bond strength of a pit-and-fissure sealant associated with two adhesive systems after salivary contamination: influence of individual and simultaneous light curing

Jaciara Miranda Gomes da Silva 06 August 2007 (has links)
Este trabalho teve por objetivo avaliar \"in vitro\" a resistência ao cisalhamento de um selante resinoso (Fluroshield - F) em associação com um sistema adesivo total-etch (Adper Single Bond 2-SB) e um self-etching (Clearfil S3 Bond-S3) em condições de contaminação salivar, comparando dois protocolos de fotopolimerização: individual do sistema adesivo e, em seguida, do selante ou simultânea de ambos materiais conjuntamente. Superfícies mesiais e distais de 45 terceiros molares humanos hígidos foram incluídas e planificadas, o sítio de adesão delimitado (Ø 3mm) e os corpos-de-prova alocados aleatoriamente em 6 grupos experimentais (n=15), de acordo com o tratamento empregado: I- F aplicado sobre o esmalte condicionado com ácido fosfórico a 37% (controle). Os demais grupos foram contaminados com saliva (0,01ml por 10 s) e a seguir foram aplicados: II- SB e F fotopolimerizados separadamente; III- SB e F fotopolimerizados conjuntamente; IVS3 e F fotopolimerizados separadamente; V- S3 e F fotopolimerizados simultaneamente; VI- F aplicado sem associação com adesivos sobre o esmalte condicionado e contaminado. A seguir, um cilindro de selante foi confeccionado com o auxílio de uma mesa metálica e de matriz de teflon bipartida sobre o sítio de adesão. Após armazenamento durante 24 horas a 37°C em água destilada, os espécimes foram submetidos ao teste de resistência ao cisalhamento em Máquina de Ensaios Universal (0,5mm/min; 50Kgf). As interfaces adesivas foram analisadas quanto ao tipo de fratura em microscópio óptico com 20x de aumento e para análise qualitativa, três espécimes de cada grupo, foram selecionados e analisados em microscópio eletrônico de varredura. As médias obtidas, em MPa, e os desvios padrão foram: I-12,28 (±4,29); II-8,57 (±3,19); III-7,97 (±2,16); IV-12,56 (±3,11); V- 11,45 (±3,77); e VI-7,47 (±1,99). A análise estatística, por meio da Análise de Variância e teste de Fisher, demonstrou que a contaminação salivar afetou negativamente a resistência adesiva. A associação do sistema adesivo self-etching ao selante resultou em uma média semelhante estatisticamente ao grupo controle. Comparando os protocolos de fotopolimerização, não houve diferença estatisticamente significante entre os grupos nos quais foi realizada a fotopolimerização simultânea ou individual dos materiais. Com base nestes resultados pôde-se concluir que o protocolo de fotopolimerização não afetou os valores de resistência adesiva ao esmalte condicionado e contaminado. A associação do sistema adesivo self-etching Clearfil S3 Bond ao selante Fluroshield aumentou a resistência ao cisalhamento com diferença estastísticamente significante em relação aos grupos nos quais foi utilizado o sistema adesivo Adper Single Bond 2 e com valor médio semelhante ao grupo controle, no qual o selante foi aplicado em condições ideais, na ausência de contaminação salivar. / The purpose of this study was to evaluate in vitro the shear bond strength of a resin-based pit-and-fissure sealant (Fluroshield - F) associated with a total-etch (Adper Single Bond 2 - SB) and a self-etching adhesive system (Clearfil S3 Bond - S3) under conditions of salivary contamination, comparing two curing protocols: individual light curing of the adhesive system and the sealant or simultaneous curing of both materials. Mesial and distal surfaces from 45 sound third molars were embedded, flattened and a 3-mm-diameter bonding site was demarcated. The specimens were randomly assigned to 6 experimental groups (n=15), according to the bonding technique: I - F was applied to the enamel etched with 37% phosphoric acid. The other groups were contaminated with saliva (0.01 mL during 10 s). II - SB and F were light cured separately; III - SB and F were light cured together; IV - 3S and F were light cured separately; V - 3S and F were light cured simultaneously; VI - F was applied to salivary-contaminated etched enamel without an intermediate bonding agent layer. Thereafter, a sealant cylinder was fabricated using a metallic clamping device and a split Teflon matrix placed over the bonding site. After 24-hour storage in distilled water at 37°C, shear bond strength was measured using a knifeedge blade in a universal testing machine (0.5 mm/mm; 50 kgf). The debonded interfaces were examined with an optical microscope to determine the failure modes. For a qualitative analysis, 3 specimens from each group were selected and observed under scanning electron microscopy. Means (±SD) in MPa were: I-12,28 (±4,29); II 8,57 (±3,19); III-7,97 (±2,16); IV-12,56 (±3,11); V-11,45 (±3,77); and VI-7,47 (±1,99). Statistical analysis by ANOVA and Fisher\'s test showed that salivary contamination affected negatively the bond strength. The association between the self-etching adhesive system and sealant yielded bond strength mean statistically similar to that of the control group. Comparing the curing protocols, there was no statistically significant difference between the groups with simultaneous or individual light curing of the materials. Based on these results, it may be concluded that the curing protocol did not affect the bond strength to the contaminated etched enamel. The association of Clearfil S3 Bond self-etching adhesive system to Fluroshield sealant increased the shear bond strength with statistically significant difference from the groups with Adper Single Bond 2 adhesive system, and showing mean value similar to that of the control group, in which the sealant was applied under ideal conditions, without salivary contamination.
615

Identificação de microRNAs envolvidos com a maciez da carne em bovinos da raça Nelore / Identification of microRNAs involved in meat tenderness in Nellore cattle

Kappeler, Berna Inés Giménez 10 November 2015 (has links)
O Brasil ocupa a segunda posição mundial na produção de carne bovina, a implantação de novas ferramentas para a seleção de animais zebuínos (Bos indicus) com carne de melhor qualidade tem uma importante contribuição para a competividade da pecuária de corte. Neste contexto, compreender os padrões de expressão de microRNAs específicos envolvidos nos processos que afetam a maciez da carne é fundamental para a sua produção, uma vez que essa característica organoléptica é de grande valor na aceitação deste alimento pelos consumidores. O advento das tecnologias de sequenciamento de nova geração em conjunto com o uso de ferramentas de bioinformática tem permitido o estudo do genoma em larga escala de forma mais rápida e com menor custo. Para este estudo, foram utilizadas amostras do músculo Longissimus dorsi de 34 animais da raça Nelore com medidas extremas de valor genético estimado (EBV) para força de cisalhamento (FC). Os RNAs totais foram extraídos, as bibliotecas de microRNA foram construídas e os sequenciamentos foram realizados em equipamento da plataforma Illumina (MiSeq). O processamento dos dados foi feito por meio dos softwares FastQC, Cutadapt e miRDeep2 e as análises de expressão diferencial foram realizadas por meio do programa estatístico QuasiSeq. Utilizando um critério de taxa de descoberta de falsos positivos (FDR) inferior a 0,1, três microRNAs (bta-mir-182, bta-mir-183, bta-mir-338) foram identificados como diferencialmente expressos entre os grupos de animais com valores extremos de EBV para FC. Um total de 1204 genes alvos foi previsto e análises funcionais de enriquecimento foram realizadas por ferramentas de bioinformática. Várias redes e vias metabólicas como a sinalização de apoptose e regulação dos mecanismos celulares pela protease calpaína foram obtidas, demonstrando assim que os genes alvos identificados estariam envolvidos em muitos processos metabólicos relacionados com a maciez da carne bovina. / Brazil occupies the second world position in beef production and thus, the implementation of new tools to select zebuine animals (Bos indicus) with better beef quality has an important contribution to the competitiveness of beef cattle. Inside this context, to comprehend the microRNAs expression patterns involved in the processes that are related to beef tenderness is essential to the meat production since this organoleptic characteristic has a high value in meat acceptance by the consumers. The advent of new generation sequencing technologies along with the biotechnology tools usage has allowed large-scale genome studies as well as faster and cheaper analysis. In this study, samples of the Longissimus dorsi muscle from 34 animals of Nellore cattle breed with extreme estimated genetic value (EBV) for shear force (FC) were used. The total RNAs were extracted, libraries of microRNA were built and finally the sequencing was performed using the Illumina (MiSeq) platform equipment. Data processing was done using FastQC, Cutadapt and miRDeep2 softwares while the differential expression analyzes were realized through the statistical package QuasiSeq. Using a false discovery rate (FDR) criteria below 0.1, three microRNAs (bta-mir- 182, bta-mir-183, bta-mir-338) were identified as differentially expressed among the group of animals with extreme EBV values for FC. A total of 1024 target genes were predicted and functional analyzes of enrichment were performed using bioinformatics tools. Many metabolic networks and pathways such as the apoptosis signalization and cell regulation mechanisms by calpain protease were obtained, demonstrating therefore that the identified target genes would be involved in many metabolic processes related with the beef tenderness.
616

Viga mista de aço e concreto constituída por perfil formado a frio preenchido / Composite steel and concrete beam constituted by filled cold-formed steel section

Chaves, Igor Avelar 20 January 2009 (has links)
As vigas mistas de aço e concreto têm sido amplamente empregadas em edifícios e pontes, havendo ampla investigação teórica e experimental a respeito da utilização de perfis laminados e soldados e conectores de cisalhamento compatíveis com esses perfis, como por exemplo, o conector tipo pino com cabeça (stud bolt) e perfil U laminado. No âmbito dos perfis formados a frio, a utilização do sistema misto ainda é incipiente, necessitando de investigações mais aprofundadas a respeito do comportamento estrutural e a adequação dos modelos de cálculo adotados para vigas mistas em perfis laminados e soldados. No Brasil, a ampla disponibilidade de aços planos tem impulsionado o emprego do sistema misto constituído por perfis formados a frio em edifícios de pequeno porte, porém, mediante concepções clássicas, o que não conduz a um aproveitamento mais racional do sistema. Neste trabalho foi investigado um sistema não-convencional de vigas mistas em perfil cartola leve preenchido com concreto, cuja conexão com a laje foi feita mediante duas soluções: conectores do tipo alça em barra chata soldados ao perfil e conectores do tipo alça em barra redonda soldados ao perfil. Foi feita avaliação do comportamento estrutural da conexão aço-concreto, via ensaios de cisalhamento direto (push-out tests), e ensaios em vigas mistas simplesmente apoiadas para avaliação da região de momento fletor positivo. Os conectores de cisalhamento apresentaram ductilidade e resistência compatíveis com as vigas mistas analisadas, e as respostas de rigidez e resistência à flexão para uma condição de interação completa comprovam que a hipótese de plastificação total da seção descreve com precisão o comportamento estrutural do sistema proposto. / The composite steel and concrete beams have been largely applied in buildings and bridges constructions, having also a large amount of theoretical and experimental investigations about the use of hot-rolled and welded shapes and shear connectors that are compatible with these members, as for an example, the stud bolt and channel connectors. In the cold-formed steel sections scope, the use of a composite steel and concrete solution is still premature, what makes necessary a higher degree of a structural behavior investigation and the adequacy of the theoretical solutions proposed, also for the composite steel and concrete hot-rolled and welded shapes. In Brazil, the high availability of steel sheets has pushed the employee of the composite system of cold-formed steel in small and mid-height buildings, however, because of classical conceptions, it doesn\'t lead too a more rational use of the system. It was investigated in this work a non-conventional lightweight composite system formed by hat-shaped beams filled with concrete, witch connection with the slab was done by means of two solutions: arc-shaped connectors in at bars welded too the section and arc-shaped connectors in round bars welded too the section. An analysis was conducted for evaluation of the structural behavior in the steel and concrete interface by push-out tests, and tests in simple two points supported beams for evaluation of the bending strength. The shear connectors showed ductility and resistance compatible with the analyzed composite beams and the stiffness and bending resistance responses for the given condition of full interaction showed that the full section plastification consideration describes with precision the structural behavior of the proposed system.
617

Shear wave elastography with two-dimensional ultrasound transducer. / Elastografia por onda de cisalhamento com transdutor de ultrassom bidimensional.

Santos, Djalma Simões dos 30 July 2018 (has links)
Chronic liver diseases are the eighth leading cause of death in Brazil and a major public health problem in the world. Liver biopsy is the best available reference standard for evaluating and classifying stages of liver diseases, but it presents limitations and complications that are common in invasive methods. In recent years, elasticity imaging methods have been the focus of intense research activity with the ability to measure mechanical properties of soft tissues in a non-invasive way. Shear wave elastography is one of the most promising methods because it enables to quantitatively assess tissue elasticity. However, the current depth range of shear wave elastography impedes its application in obese patients, which have a great risk of developing liver disease. The aim of this study is to investigate the use of shear wave elastography in deeper tissues using a two-dimensional ultrasound transducer array. An efficient transducer array arrangement was simulated, fabricated and characterized. The results show that the proposed transducer configuration presents enhanced transmitting capabilities for generating tissue displacement in deeper tissues. In addition, numerical simulations were performed in order to track the tissue deformation and reconstruct its elastic properties. / Doenças crônicas do fígado são a oitava causa de morte no Brasil e um dos principais problemas de saúde pública do mundo. A biópsia do fígado é o melhor padrão de referência disponível para avaliação e classificação dos estágios das doenças hepáticas, mas apresenta limitações e complicações que são comuns nos métodos invasivos. Nos últimos anos, métodos de imagem por elasticidade têm sido o foco de intensa atividade de pesquisa, pois têm a capacidade de medir propriedades mecânicas dos tecidos moles de maneira não invasiva. A elastografia por ondas de cisalhamento é um dos métodos mais promissores, pois permite avaliar quantitativamente a elasticidade do tecido. No entanto, a atual faixa de profundidade da elastografia por ondas de cisalhamento impede sua aplicação em pacientes obesos, que apresentam grande risco de desenvolver doença hepática. O objetivo deste estudo é investigar o uso da elastografia por onda de cisalhamento em tecidos mais profundos usando um transdutor de ultrassom bidimensional. Uma configuração eficiente de transdutores matriciais foi simulada, fabricada e caracterizada. Os resultados mostram que o transdutor proposto possui capacidade de transmissão melhorada para gerar deslocamento em tecidos profundos. Além disso, simulações numéricas foram realizadas para monitorar a deformação do tecido e reconstruir suas propriedades elásticas.
618

Análise do comportamento dinâmico da ligação formada por barras de aço coladas para tabuleiros mistos de madeira e concreto para pontes / Analysis of the dynamic behavior of the connectors formed by bonded-in steel rods for log-concrete composite deck bridges

Molina, Julio Cesar 26 May 2008 (has links)
Neste trabalho avaliou-se o comportamento estrutural do sistema misto madeira-concreto para tabuleiros de pontes, com ênfase na análise dinâmica dos conectores de cisalhamento, para dois tipos de conectores: \"vertical\" e em \"X\". Foram efetuadas duas principais abordagens, numérica e experimental, além de um amplo levantamento teórico sobre o tema com base na literatura disponível. Os ensaios experimentais foram realizados em corpos-de-prova de madeira como também em corpos-de-prova mistos e vigas mistas de madeira-concreto. Todos os corpos-de-prova e vigas foram submetidos a solicitações estáticas e dinâmicas, considerando-se os diversos materiais envolvidos na ligação. A análise numérica dos sistemas mistos foi efetuada com base no método dos elementos finitos, a partir da utilização do software ANSYS. Os resultados experimentais mostraram que ambos os sistemas de conexão perderam efetivamente rigidez para um total de 1 x \'10 POT.6\' ciclos de carga aplicados, sendo a maior parcela desta perda verificada para os ciclos iniciais. Além disso, o sistema de conexão \"vertical\" apresentou maior facilidade de execução quando comparado com o sistema de conexão em \"X\". A partir dos resultados numéricos constatou-se que a perda de rigidez ocorreu devido ao acúmulo do dano localizado nos materiais, nas regiões dos conectores. Os resultados numéricos mostraram uma boa concordância com os resultados experimentais. Para finalizar, foram propostos os valores dos níveis máximos e mínimos de carga cíclica, como também da frequência de excitação a serem utilizados nos ensaios dinâmicos para a verificação da rigidez dos sistemas mistos de conexão. / In this work was evaluated the structural behavior of log-concrete composite deck bridge system, with emphasis in the dynamic analysis of the shear connectors using two types of connectors: \"vertical\" and \"X\". Two main approaches were considered, numeric and experimental, besides a wide theoretical study about the theme with base in the available literature. The experimental studies were accomplished in specimens of wood, wood-concrete specimens and wood-concrete beams. All of the specimens and beams were subjected to static and dynamic loads considering several materials in the composed connection system. The numeric analyze of the composed systems was made with base in the method of the finite elements using the software ANSYS. The experimental results showed that both connection systems reduced stiffness really for 1 x \'10 POT.6\' applied load cycles, and the largest portion of this reduction happens in the initial cycles. Besides, the system of \"vertical\" connection presented larger execution easiness when compared with the system \"X\" connection. The numeric results showed that the reduced stiffness of the connection systems happened due to the accumulation of the located damage of the materials in the areas of the connectors. The numeric and experimental results comparison showed a good agreement. It was proposed values for the maximum and minimum levels of cyclical load, as well as for the frequency to be used in the dynamic tests for the verification of the reduced stiffness of the composite system of connection.
619

Análise experimental de vigas pré-formadas de concreto armado à flexão e ao cisalhamento / Experimental analysis of reinforced concrete preformed beams to bending and shear

MELO, José Guilherme Silva 20 June 2008 (has links)
Made available in DSpace on 2011-03-23T21:19:31Z (GMT). No. of bitstreams: 0 / Item created via OAI harvest from source: http://www.bdtd.ufpa.br/tde_oai/oai2.php on 2011-03-23T21:19:31Z (GMT). Item's OAI Record identifier: oai:bdtd.ufpa.br:224 / Reinforced concrete preformed beams are structural elements which present a thin superficial precast concrete layer that defines their geometrical shapes. This superficial layer functions as a formwork that will be incorporated to the beam after the introduction of cast in loco concrete, which will consolidate the structure. This construction system presents advantages when compared to the conventional construction system as the reduction of wood consumption used to produce formworks and supports. Comparing to the precast structural system, the major advantages are the transport cost reduction and the quick assembling of the structural elements due to its lower self weight. Another advantage is the greater stiffness of a preformed structure, when compared to a precast one, because it is possible to make monolithic joints between the structural elements using proper reinforcement combined with cast in loco concrete. This research aims to analyze experimentally the behavior of preformed beams under bending and shear carrying out tests over 9 preformed beams and 3 common reinforced concrete beams as reference. The beams have width of 110 mm, 340 mm height and length of 2,500 mm. Experimental results will be compared to the ones obtained using the recommendations of the Brazilian design code and the main international codes. Results of vertical deflection, strains on concrete compressed zone, strains on flexural and shear reinforcement and cracking pattern will be presented and analyzed. / Vigas pré-formadas de concreto armado são elementos estruturais que apresentam fina camada superficial de concreto pré-moldado que define as suas formas geométricas. Esta camada superficial trabalha como forma que fica incorporada à viga após o lançamento do concreto moldado in loco, que consolidará a estrutura. Este sistema construtivo apresenta vantagem em relação ao sistema construtivo convencional por reduzir o consumo de madeira com formas e escoramento, e também em relação ao sistema pré-moldado por reduzir o custo de transporte e montagem da estrutura. Os elementos pré-formados apresentam menor peso em relação aos elementos pré-moldados, por apresentarem a seção parcialmente pré-moldada. Outra vantagem do sistema pré-formado em relação ao pré-moldado é a possibilidade de se obter maior rigidez nas ligações das vigas com o restante da estrutura com a colocação de armadura de engastamento ancorada no concreto moldado in loco. Este trabalho tem como objetivo analisar experimentalmente o comportamento das vigas pré-formadas à flexão e ao cisalhamento, através de ensaios de 9 vigas pré-formadas e 3 vigas maciças de referência. As vigas têm largura de 105 mm, altura de 340 mm e 2.500 mm de comprimento. Os resultados obtidos nos ensaios experimentais são comparados aos valores fornecidos pelas normas técnicas brasileiras e as principais normas internacionais. São apresentados e analisados os resultados observados para os deslocamentos verticais das vigas, deformações da armadura de flexão e da armadura de cisalhamento, deformações do concreto nas regiões de compressão e mapas de fissuração.
620

Análise experimental de lajes lisas nervuradas de concreto armado com armadura de cisalhamento / Experimental nervuradas smooth flagstone analysis of reinforcement concrete with shear armor

SOUZA, Shirley do Socorro Melo de 11 January 2007 (has links)
Made available in DSpace on 2011-03-23T21:19:40Z (GMT). No. of bitstreams: 0 / Item created via OAI harvest from source: http://www.bdtd.ufpa.br/tde_oai/oai2.php on 2011-03-23T21:19:40Z (GMT). Item's OAI Record identifier: oai:bdtd.ufpa.br:300 / Two-way waffle flat slabs are structural elements of reinforced concrete supported directly on columns, under bending moments over the two directions, they improve the speed of the execution and save moulds and concrete and, consequently, labor. This work seeks to contribute for the study of the behavior of this kind of slab, as the shear resistance of the ribs and the punching in the solid area, through tests of 8 two-way reinforced concrete waffle flat slabs. Comparative analyses between the experimental results and estimated by national and international design codes had been carried out. The slabs were square, with 1.800 mm of side and total height of 140 mm. The cross section of the slabs was formed by ribs with 50 mm of width for the base and 100 mm for the upper base and the spaces between the ribs had been filled with EPS blocks (expanded polystyrene). The main variables considered were the type of shear reinforcement in the ribs (trusses, closed vertical stirrup and 45 inclined stirrup) and the use of 45 inclined stirrup as shear reinforcement in the solid region. They were presented and analyzed the results observed for the vertical displacements, deformation in the flexural and shear reinforcement, and the propagation of cracks. The values observed for failure loads were compared with the estimated ones. It was observed that the shear reinforcement in the ribs did not increase the failure loads and that the shear reinforcement in the solid region increased significantly the resistance of the slabs. / Lajes lisas nervuradas bidirecionais são elementos estruturais de concreto armado apoiados diretamente sobre pilares, sujeitas a solicitações importantes nas duas direções, possibilitam maior velocidade na execução da obra e economia considerável de formas e concreto e, conseqüentemente, mão-de-obra. Este trabalho visa contribuir para o estudo do comportamento deste tipo de laje, quanto a resistência ao cisalhamento nas nervuras e à punção na região maciça das lajes, através de ensaios de 8 lajes lisas nervuradas bidirecionais de concreto armado. Foram realizadas análises comparativas entre os resultados obtidos experimentalmente e os fornecidos por normas técnicas nacionais e internacionais. As lajes eram quadradas de lado igual a 1.800 mm de comprimento e altura total de 140 mm. A seção transversal das lajes foi formada por nervuras de 50 mm de largura na base menor e 100 mm na base maior e os vazios entre as nervuras foram preenchidos com blocos de EPS (poliestireno expandido). As principais variáveis consideradas foram o tipo de armadura de cisalhamento nas nervuras (treliça, estribo vertical fechado e estribo aberto inclinado a 45) e a utilização de estribo aberto inclinado a 45 como armadura de punção na região maciça. Foram apresentados e analisados os resultados observados para os deslocamentos verticais, deformação nas armaduras de cisalhamento e de flexão, e a propagação das fissuras. Os valores observados para cargas últimas foram comparados com os resultados estimados. Observou-se que as armaduras de cisalhamento nas nervuras não ocasionaram ganhos significativos na resistência última e que a armadura de punção elevou significativamente a resistência das lajes.

Page generated in 0.274 seconds