• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 180
  • 11
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 197
  • 197
  • 99
  • 98
  • 69
  • 55
  • 42
  • 38
  • 23
  • 23
  • 22
  • 22
  • 20
  • 19
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação de um aparelho de luz halógena e um dispositivo Leds na técnica de fotoativação trans-dental : estudo da profundidade de polimerização pelos testes de dureza e espectroscopia de fluorescência /

Rastelli, Alessandra Nara de Souza. January 2004 (has links)
Orientador: Marcelo Ferrarezi de Andrade / Banca: Fernando Carlos Hueb de Menezes / Banca: João Carlos Gomes / Banca: José Roberto Cury Saad / Banca: Vanderlei Salvador Bagnato / Resumo: O objetivo desse trabalho foi avaliar a capacidade de polimerização de uma fonte de luz halógena e um dispositivo LEDs utilizados na técnica de fotoativação trans-dental. Para isto, foram confeccionadas amostras em uma matriz metálica circular contendo um orifício central com 4 mm de diâmetro e 2 mm de profundidade (ISO 4049) utilizando-se a resina composta microhíbrida Filtek Z-250 (3M/ESPE), na cor A2. Cinco amostras foram confeccionadas para cada situação diferente, distribuídas em grupos da seguinte maneira: GRUPO I - aparelho Curing Light e dispositivo LEDs utilizados pelos tempos de exposição de 40 e 60 segundos, para as espessuras de 0 (grupo controle); 1,0 mm; 2,0 mm e 3,0 mm de faceta de estrutura dental, nas mesmas condições de operação armazenados em meio seco por 24 horas, avaliados pelo teste de dureza Vickers (VHN); GRUPO II - aparelho Curing Light e dispositivo LEDs utilizados pelos tempos de exposição de 40 e 60 segundos, para as espessuras de 0 (grupo controle); 1,0 mm; 2,0 mm e 3,0 mm de faceta de estrutura dental nas condições originais de operação armazenados em meio seco por 24 horas e 30 dias, água destilada, saliva artificial e ácido acético a 10% por 30 dias, avaliados pelo teste de dureza Vickers (VHN) e GRUPO III - aparelho Curing Light e dispositivo LEDs utilizados pelos tempos de exposição de 40 e 60 segundos, para as espessuras de 0 (grupo controle); 1,0 mm; 2,0 mm e 3,0 mm de faceta de estrutura dental armazenados em rodamina 6G durante 24 horas sendo avaliados pelo teste de espectroscopia de fluorescência. Os dados foram submetidos à Análise Estatística de Variância (p<0,05) e complementadas por comparações múltiplas pelo teste de Newman-Keuls ao nível de 5% de significância. Baseados nos resultados encontrados, pudemos concluir que: 1) a fonte de luz halógena testada proporcionou... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The objective of this study was evaluate the light-curing capacity, throught dental structure, of two differents light-curing device (Halogen and LEDs), by hardness and fluorescent spectroscopic testings. The samples were made in a circular metallic mold with a orifice in the central portion measuring 4 mm in diameter and 2 mm in thickness (ISO 4049). The composite resin was used the Filtek Z-250 (3M/ESPE) at collor A2. Five samples were made by situation analyzed: GROUP I - halogen and LEDs light-curing devices by exposure times of 40 and 60 seconds for the thickness 0 (control group); 1,0 mm; 2,0 mm and 3,0 mm of the structure dental facet, at the same operation parameters stored in dry mean for 24 hours; GROUP II - halogen and LEDs light-curing devices by exposure times of 40 and 60 seconds for the thickness 0 (control group); 1,0 mm; 2,0 mm and 3,0 mm of the structure dental facet, at the original operation parameters stored in dry mean for 24 hours and thirty days, distilled water, artificial saliva and acetic acid at 10% for thirty days and GROUP III - halogen and LEDs light-curing devices by exposure times of 40 and 60 seconds for the thickness 0 (control group); 1,0 mm; 2,0 mm and 3,0 mm of the structure dental facet stored in 6G rodhamine evaluated for fluorescent spectroscopic testing. The data were submitted to the Statistical Analysis of Variance (p <0,05) and complemented by multiple comparisons by the test of Newman-Keuls at the level 5% of significance. Based on the found results, we could end that: 1) the device of tested halogen light provided larger curing of depth for the trans-dental technique; 2) the device LEDs promoted larger curing of depth for the trans-dental technique, when the source of halogen light was used in the same operation parameters; 3) in the technique trans-dental, independent of the source of used... (Complete abstract, click electronic address below). / Doutor
22

Avaliação de um aparelho de luz halógena e um dispositivo Leds na técnica de fotoativação trans-dental: estudo da profundidade de polimerização pelos testes de dureza e espectroscopia de fluorescência

Rastelli, Alessandra Nara de Souza [UNESP] 09 November 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-11-09Bitstream added on 2014-06-13T19:20:25Z : No. of bitstreams: 1 rastelli_ans_dr_arafo.pdf: 1588793 bytes, checksum: f1face4ce729ada146c1f40f26e0748f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo desse trabalho foi avaliar a capacidade de polimerização de uma fonte de luz halógena e um dispositivo LEDs utilizados na técnica de fotoativação trans-dental. Para isto, foram confeccionadas amostras em uma matriz metálica circular contendo um orifício central com 4 mm de diâmetro e 2 mm de profundidade (ISO 4049) utilizando-se a resina composta microhíbrida Filtek Z-250 (3M/ESPE), na cor A2. Cinco amostras foram confeccionadas para cada situação diferente, distribuídas em grupos da seguinte maneira: GRUPO I - aparelho Curing Light e dispositivo LEDs utilizados pelos tempos de exposição de 40 e 60 segundos, para as espessuras de 0 (grupo controle); 1,0 mm; 2,0 mm e 3,0 mm de faceta de estrutura dental, nas mesmas condições de operação armazenados em meio seco por 24 horas, avaliados pelo teste de dureza Vickers (VHN); GRUPO II - aparelho Curing Light e dispositivo LEDs utilizados pelos tempos de exposição de 40 e 60 segundos, para as espessuras de 0 (grupo controle); 1,0 mm; 2,0 mm e 3,0 mm de faceta de estrutura dental nas condições originais de operação armazenados em meio seco por 24 horas e 30 dias, água destilada, saliva artificial e ácido acético a 10% por 30 dias, avaliados pelo teste de dureza Vickers (VHN) e GRUPO III - aparelho Curing Light e dispositivo LEDs utilizados pelos tempos de exposição de 40 e 60 segundos, para as espessuras de 0 (grupo controle); 1,0 mm; 2,0 mm e 3,0 mm de faceta de estrutura dental armazenados em rodamina 6G durante 24 horas sendo avaliados pelo teste de espectroscopia de fluorescência. Os dados foram submetidos à Análise Estatística de Variância (p<0,05) e complementadas por comparações múltiplas pelo teste de Newman-Keuls ao nível de 5% de significância. Baseados nos resultados encontrados, pudemos concluir que: 1) a fonte de luz halógena testada proporcionou... . / The objective of this study was evaluate the light-curing capacity, throught dental structure, of two differents light-curing device (Halogen and LEDs), by hardness and fluorescent spectroscopic testings. The samples were made in a circular metallic mold with a orifice in the central portion measuring 4 mm in diameter and 2 mm in thickness (ISO 4049). The composite resin was used the Filtek Z-250 (3M/ESPE) at collor A2. Five samples were made by situation analyzed: GROUP I - halogen and LEDs light-curing devices by exposure times of 40 and 60 seconds for the thickness 0 (control group); 1,0 mm; 2,0 mm and 3,0 mm of the structure dental facet, at the same operation parameters stored in dry mean for 24 hours; GROUP II - halogen and LEDs light-curing devices by exposure times of 40 and 60 seconds for the thickness 0 (control group); 1,0 mm; 2,0 mm and 3,0 mm of the structure dental facet, at the original operation parameters stored in dry mean for 24 hours and thirty days, distilled water, artificial saliva and acetic acid at 10% for thirty days and GROUP III - halogen and LEDs light-curing devices by exposure times of 40 and 60 seconds for the thickness 0 (control group); 1,0 mm; 2,0 mm and 3,0 mm of the structure dental facet stored in 6G rodhamine evaluated for fluorescent spectroscopic testing. The data were submitted to the Statistical Analysis of Variance (p <0,05) and complemented by multiple comparisons by the test of Newman-Keuls at the level 5% of significance. Based on the found results, we could end that: 1) the device of tested halogen light provided larger curing of depth for the trans-dental technique; 2) the device LEDs promoted larger curing of depth for the trans-dental technique, when the source of halogen light was used in the same operation parameters; 3) in the technique trans-dental, independent of the source of used... (Complete abstract, click electronic address below).
23

Análise in vitro da resistência adesiva de resinas compostas em cavidades de classe II, através do teste de microtração. Efeito de diferentes técnicas restauradoras

Calixto, Abraham Lincoln [UNESP] 22 July 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:27Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-07-22Bitstream added on 2014-06-13T20:01:56Z : No. of bitstreams: 1 calixto_al_dr_arafo.pdf: 933718 bytes, checksum: 50e18e9960ea9272e8e8efc853a8ef95 (MD5) / O objetivo deste trabalho foi analisar in vitro a resistência adesiva, em cavidades de classe II, restauradas com resinas compostas, através do teste de microtração . Foram realizadas cavidades padronizadas, de classe II, tipo slot, nas superfícies mesial e distal de 24 dentes terceiros molares humanos e hígidos. Os dentes foram aleatoriamente divididos em 6 grupos com 16 espécimes cada. O procedimento restaurador foi realizado através de técnica de incrementos múltiplos com as resinas compostas P60 (compactável) e Z250 (multiuso), sob efeito de diferentes técnicas restauradoras, a saber: Grupo PT1- adesivo + P60 ; Grupo PT2- adesivo + P60 + ponta fotocondensadora transparente; Grupo PT3- adesivo + flow + P60; Grupo ZT1- adesivo + Z250; Grupo ZT2- adesivo + Z250 + ponta fotocondensadora transparente; Grupo ZT3- adesivo + flow + Z250. O sistema adesivo utilizado foi o Single Bond (3M ESPE). Após as restaurações, os dentes foram armazenados em água destilada em estufa a 37°C, durante 24 horas. A seguir, os dentes foram termociclados por 500 ciclos (5°-55°) e então, seccionados paralelamente ao longo eixo com disco diamantado, no sentido vestíbulo - lingual e mesio - distal, obtendo-se amostras em forma de palitos, com área de secção transversal de 0,50mmøl0,1mmø . Antes do teste de tração, os palitos tiveram suas áreas de união medidas e anotadas, e então, foram fixados pelas suas extremidades ao dispositivo de microtração com um adesivo instantâneo e a seguir, submetidos ao ensaio de tração em máquina de testes universal (MTS) operada a velocidade de 0,5mm/min. Após a fratura, os valores de resistência adesiva foram calculados e expressos em MPa. O modo da fratura no lado de dentina foi classificada individualmente, com lupa estereoscópica com aumento de 40X. Os dados foram submetidos a análise estatística e demonstrou... / The aim of this work was to analyse in vitro of the tensile bond strength in class II cavities, recuperated with composite resins, throught the microtensile bond test. Standardized cavities were prepared, slot type , in the surfaces mesial and distal of 24 humans molars teeth third and health. The restorations procedures were carried out using the technique of multiple increments with P60 and Z250 resin. The teeth were randoly divided in to 6 groups of 16 specimens each, to know: Group PT1- adhesive+P60; Group PT2- adhesive+P60+ transparent photocondenser point; Group PT3-ahesive+flow+P60; Group ZT1-adhesive+Z250; Group ZT2- adhesive+Z250+ transparent photocondenser point; Group ZT3- adhesive+flow+Z250. The adhesive system were utilized Single Bond (3M/ESPE). After the restorations, the teeth were storage in destilled water for 24h at 37°C. After were thermocycled for 500 cycles at preset temperatures of 5° and 55°C, and the teeth were sectioned with a diamond disc, perpendicularly to the adhesive interface in buccal-lingual an mesio-distal directions, being obtained samples in sticks form with cross-sectional areas of 0,5 mmø. Before testing sticks had their measured and logged union areas. The specimens were then attached to a testing apparatus and tensile load was applied by universal machine at a crosshead speed of 0.5mm/min. After the fracture values of the tensile bond strenght were calculated and expressed in MPa. The dentin surfaces surfaces was examined with aid of glass magnifying stereoscopic with 40X, being verifield the way of failures. The results were submitted statistical analysis showed : 1- the largest values of shear bond strenght went to the group PT2, wich associated the resin P60 with the point photocondenser transparent; 2- the groups that you/they the resin flow didn't present... (Complete abstract, click electronic address below)
24

Resistência á compressão de restauração de resina composta em preparos de classe II

Cioffi, Sabrina Spinelli [UNESP] 18 March 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-03-18Bitstream added on 2014-06-13T19:30:40Z : No. of bitstreams: 1 cioffi_ss_me_arafo.pdf: 226725 bytes, checksum: e69424b0b101d7404c408391d46af41f (MD5) / Proposição: o presente estudo tem como objetivo avaliar a resistência à compressão de restaurações de resina composta em preparos classe II, observando o tipo de preparo que possui maior resistência à compressão permitindo obter um modelo de restauração classe II com características adequadas, garantindo a qualidade da restauração, assim como sua durabilidade. Material e método: os dentes foram divididos em cinco grupos contendo oito dentes por grupo, sendo eles; Grupo 1-controle, Grupo 2- preparo mésio-oclusal com bisel, Grupo 3- preparo mesial sem canaleta e com bisel, Grupo 4- preparo mesial com canaleta e com bisel e Grupo 5- preparo mésio-oclusal sem bisel. Resultado: os resultados obtidos mostraram que o grupo controle obteve os maiores valores porém não foi estatisticamente significante quando comparado com os Grupos 2 e 5. Conclusão: preparos com extensão para oclusal apresentam valores satisfatórios porém devemos considerar que preparos preventivos não obtiveram diferença estatística quando comparados a esses preparos podendo ser indicados em casos de lesões de cárie apenas proximais. / Objective: The present study aims to evaluate the compressive strength of composite resin restorations in Class II preparations, noting the type of preparation that has greater compressive strength allowing to obtain a Class II restoration model with appropriate characteristics, ensuring the quality of restoration, as well as its durability. Methods: The teeth were divided into five groups containing eight teeth each group; Group 1- control, Group 2- mesio-occlusal preparation with bevel; Group 3- mesial preparation without groove and with bevel; Group 4- mesial preparation with groove and bevel; Group 5- mesio-occlusal preparation without bevel. Results: The results showed that the control group had higher values but not statistically significant when compared with Groups 2 and 5. Conclusion: Preparations with occlusal extension exhibited satisfactory values but we must consider that preventive preparations did not obtain satatistical difference when compared to these preparations and may be indicated in cases of only proximal carious lesions.
25

Avaliação da influência do selante de superfície sobre a translucidez de resina composta. Efeito de tempos e soluções

Rodrigues Neto, Elídio [UNESP] 20 December 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-12-20Bitstream added on 2014-06-13T19:10:20Z : No. of bitstreams: 1 rodriguesneto_e_me_arafo.pdf: 296469 bytes, checksum: 46a2478fea941cbd45701b60eb5dbff8 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O presente trabalho teve como objetivo avaliar o efeito do selante de superfície sobre a translucidez da resina composta, em função das soluções e do tempo de imersão. Para isso foram selecionados os seguintes materiais: resina composta Charisma; selante de superfície Fortify; e quatro soluções para imersão, café, Coca-Cola®, chá e Saliva Artificial. Foram confeccionados 8 corpos-de-prova para cada condição experimental, totalizando 64 corpos-de-prova. A partir disso, os mesmos permaneceram imersos em saliva artificial, mantidos em estufa a uma temperatura de 37ºCl 1, e foram retirados da estufa para imersão nas soluções testadas, três vezes ao dia por um período de cinco minutos, e após este período foram lavados em água corrente e novamente imersos em saliva artificial, até o momento determinado para a leitura da translucidez. As leituras foram realizadas em nove níveis: T1 - após a confecção dos corpos-de-prova, T2 - 24 horas após a imersão nas soluções, T3 - 48 horas após, T4 a T9, sendo respectivamente 7, 14, 21, 30, 60 e 90 dias após a imersão. Para a obtenção dos valores de translucidez (em porcentagem) foi utilizado o aparelho JOUAN. Os resultados obtidos foram submetidos à Análise de Variância e ao Teste de Tukey a 5%. Observou-se que as soluções influenciaram na translucidez dos materiais (p<0,001), sendo que o café apresentou maior ação pigmentante, seguido pelo chá, Coca-Cola® e saliva artificial. Com relação ao tempo notou-se que a partir de T5 houve uma significante alteração (p<0,001) na translucidez da resina até T8. E quanto ao selante o grupo selado apresentou maiores valores de translucidez (p<0,05) do que o grupo não selado. Mediante a metodologia aplicada pode-se concluir que o café foi a solução que promoveu maior alteração de translucidez, a resina composta sofreu alteração significativa... . / The aim of the current study was to evaluate the surface sealant effect upon the composite resin translucence, related to different solutions and immersion periods. The following materials were selected: Charisma composite resin; Fortify surface sealant; and four immersion solutions, which are coffee, Coca-Cola®, tea and Artificial Saliva. Eight test specimens were manufactured for each experimental condition, totaling 64 test specimens. All the specimens were immersed in artificial saliva and maintained in a kiln at 37ºCl 1, being then removed for a five-minute immersion period three times a day in the solutions tested, after which they were washed with tap water and immersed in artificial saliva once more until the translucence reading was performed. The readings were performed in nine levels: T1 - after test specimens manufacture, T2 - 24 hours after the immersion in the solutions, T3 - 48 hours after the immersion, T4 to T9, respectively 7, 14, 21, 30, 60 and 90 days after the immersion. In order to achieve translucence scores (in percentage), the appliance JOUAN was used. The results obtained were submitted to the Analysis of Variance and to Tukey's test at 5%. It was possible to observe that the solutions influenced on the materials translucence (p<0.001), and that coffee showed the most staining action, followed by tea, Coca-Cola® and artificial saliva. In regard to time, a significant alteration (p<0.001) was noticed in the composite resin from T5 up to T8. Considering the sealant, the sealed group showed higher scores of translucence (p<0.05) than the non-sealed group. According to the methodology applied, it is possible to conclude that coffee was the solution which provided the most intense translucence alteration, the composite resin underwent a significant alteration in translucence after 21 days of... (Complete abstract, click electronic address below).
26

Estabilidade de cor de resinas compostas em função de composição e sistema de fotoativação: avaliação através de espectroscopia de reflectância

Jorge, Juliana Ribeiro Pala [UNESP] 14 February 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-02-14Bitstream added on 2014-06-13T19:51:24Z : No. of bitstreams: 1 jorge_jrp_me_arafo.pdf: 495747 bytes, checksum: 8bd7e287cb5a1a6d051b4249dd6857bc (MD5) / A estabilidade de cor de duas resinas compostas diferentes frente ao envelhecimento físico/químico foi avaliada, em função dos seguintes fatores: composição e tipo de luz fotoativadora. Para isso, foram confeccionados 15 corpos-de-prova para a resina Filtek Supreme, e 15 corpos-de-prova para a resina 4 Seasons. Ambos os materiais foram polimerizados com três fontes de luz diferentes: uma luz halógena, e dois sistemas LEDs. Tais corpos-de-prova foram submetidos ao envelhecimento artificial, inicialmente através de imersão em água destilada por 24 horas, e após esse período foram expostos à luz ultravioleta por 24 horas, em associação à imersão em água destilada. As mensurações de cor foram realizadas com o auxílio de um espectrofotômetro de reflectância e tais mensurações, através de uma fórmula matemática apropriada, permitiu que o total de alteração de cor (?E) fosse avaliado, para todas as variações, nos seguintes períodos de tempo: após imersão em água destilada (T1-T2) e após exposição à luz ultravioleta (T1-T3). Os resultados foram submetidos à Análise de Variância, sendo que através da mesma foi possível observar que: a resina composta Filtek Supreme apresentou média de alteração de cor (DE) estatisticamente maior que a resina composta 4 Seasons; o tipo de luz fotopolimerizadora (LED ou halógena) não determinou diferenças estatísticas na propriedade de estabilidade de cor para os materiais estudados. Ambos os materiais sofreram alteração de cor significativa, tanto estatística quanto visualmente, após o processo de envelhecimento artificial. / Color stability of two different composite resins after artificial aging was evaluated, against the following factors: composition and type of photo-activating light. Therefore, 15 specimens from Filtek Supreme composite resin and 15 specimens from 4 Seasons composite resin were prepared. Both materials were polymerized with three different light devices: one halogen light and two LEDs systems. These specimens were submitted to artificial aging, initially through immersion in distilled water for 24 hours and then through exposure to ultraviolet light for 24 hours, in association with immersion in distilled water. The color mensurations were accomplished by a reflectance spectrophotometer and these mensurations, through a proper mathematical formula, allowed that the total color alteration (?E) was evaluated, for each variation, at the following period of time: after distilled water immersion (T1-T2), and after ultraviolet light exposure (T1-T3). These results were analyzed by a analysis of variance, and through this analysis it was possible to notice that: Filtek Supreme composite resin presented color alteration average (?E) statistically higher than the 4 Seasons composite resin average; the type of photopolymerization light (LED or halogen) did not define any statistical differences on color stability for both studied materials. Both materials underwent significant color alteration, both statistical and visually alterations, after the artificial aging process.
27

Influência da distância de uma fonte de luz halógena na microdureza superficial da resina composta

Alencar Júnior, Emmanuel Arraes de [UNESP] 19 February 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-02-19Bitstream added on 2014-06-13T20:12:03Z : No. of bitstreams: 1 alencarjunior_ea_me_arafo_prot.pdf: 747787 bytes, checksum: fd32e276778e87934566a313af1035b5 (MD5) / O objetivo desta pesquisa foi avaliar a influência da distância de uma fonte de luz halógena na microdureza superficial da resina composta, considerando as superfícies de topo e base dos corpos-de-prova. Foram utilizadas duas marcas comerciais de resina composta, Z250 de partículas pequenas e uma resina de micropartícula, A110, ambas da 3M do Brasil Ltda. O aparelho de ativação da resina composta foi K&M 220- R, cuja intensidade de luz possui um pulso que variava após os 5 primeiros segundos assim alcançando sua intensidade máxima que foi medida em 720 mW/cm2. Para a determinação da intensidade de luz emitida pelo aparelho fotoativador, utilizou-se um radiômetro (Medidor de irradiância 150- CMC , São Carlos - SP). Corpos-de-prova foram confeccionados utilizado-se matrizes metálicas que possuíam um orifício central de 4mm de diâmetro por 2mm de espessura. As resinas foram inseridas no orifício da matriz metálica, em um único incremento, por meio de uma espátula metálica e sobre elas foi sobreposta uma tira matriz transparente de poliéster e, após isto, um peso de 1 Kg foi posto em cima da tira para que houvesse uma melhor condensação da resina composta evitando a presença de bolhas de ar, no interior do corpo-de-prova. A fonte de luz halógena foi fixada em uma mesa de maneira que a saída da ponta de luz ficasse paralela à superfície do corpo-de-prova. Para provocar o distanciamento da fonte de luz, anéis metálicos confeccionados em latão, com espessuras que variavam de 2mm, 4mm e 8mm foram utilizados, os quais, após posicionados, eram removidos para não interferiem no dispersamento da luz. As distâncias imprimidas a fonte de luz na superfície da resina foram de 0mm(tocando a superfície), 2mm, 4mm e 8mm. Para cada uma destas distâncias, a intensidade de luz foi medida. Esta variou de intensidade de... . / The aim of this research was to evaluate the influence of the light tip distance in the superficial microhardness of the composite resin, considering the surfaces of top and base of the samples. Two commercial composite resin marks had been used, Z250 of small particles e a microparticle resin, A110, both of 3m of Brazil Ltda. The device of activation of the composite resin was K&M 220- R, whose intensity of light possess a pulse that varied the 5 first seconds after thus reaching its maximum intensity that was measured in 720 mW/cm2. For the determination of the intensity of light emitted for the fotoativador device, a radiometer (Measuring of irradiance 150- CMC was used, Is Carlos. SP). The samples had been confectioned used first metallic that had a central orifice of 4mm of diameter for 2mm of thickness. The resins had been inserted in the orifice of the metallic array, in an only increment, by means of a metallic spatula and on them a transparent first polyester strap was overlapped and, after this, one weight of 1 kg was rank in top of the strap so that it had one better condensation of the composite resin preventing the presence of air bubbles, in the inward of the body-of-test. The source of light was fixed in a table thus the output of the light tip was parallel to the surface of the body-of-test. To provoke distance from the light source, confectioned metallic rings in brass, with thickness that varied of 2mm, 4mm and 8mm had been used, which, after located, was removed to avoid concentration of light. The printed pitches the source of light in the surface of the resin had been of 0mm(on the surface), 2mm, 4mm and 8mm. For each one of these pitches, the light intensity was measured. This varied of intensity of 720 mW/cm2 for the tip touching the surface of the body-of-test, 650 mW/cm2 for in the distance of 2mm, 600 mW/cm2... (Complete abstract, click electronic address below).
28

Estabilidade de cor de resinas compostas em função de composição e sistema de fotoativação : avaliação através de espectroscopia de reflectância /

Jorge, Juliana Ribeiro Pala. January 2006 (has links)
Orientador: Osmir Batista de Oliveira Júnior / Banca: Rosane de Fátima Zanirato Lizarelli / Banca: Cristina Kurachi / Resumo: A estabilidade de cor de duas resinas compostas diferentes frente ao envelhecimento físico/químico foi avaliada, em função dos seguintes fatores: composição e tipo de luz fotoativadora. Para isso, foram confeccionados 15 corpos-de-prova para a resina Filtek Supreme, e 15 corpos-de-prova para a resina 4 Seasons. Ambos os materiais foram polimerizados com três fontes de luz diferentes: uma luz halógena, e dois sistemas LEDs. Tais corpos-de-prova foram submetidos ao envelhecimento artificial, inicialmente através de imersão em água destilada por 24 horas, e após esse período foram expostos à luz ultravioleta por 24 horas, em associação à imersão em água destilada. As mensurações de cor foram realizadas com o auxílio de um espectrofotômetro de reflectância e tais mensurações, através de uma fórmula matemática apropriada, permitiu que o total de alteração de cor (?E) fosse avaliado, para todas as variações, nos seguintes períodos de tempo: após imersão em água destilada (T1-T2) e após exposição à luz ultravioleta (T1-T3). Os resultados foram submetidos à Análise de Variância, sendo que através da mesma foi possível observar que: a resina composta Filtek Supreme apresentou média de alteração de cor (DE) estatisticamente maior que a resina composta 4 Seasons; o tipo de luz fotopolimerizadora (LED ou halógena) não determinou diferenças estatísticas na propriedade de estabilidade de cor para os materiais estudados. Ambos os materiais sofreram alteração de cor significativa, tanto estatística quanto visualmente, após o processo de envelhecimento artificial. / Abstract: Color stability of two different composite resins after artificial aging was evaluated, against the following factors: composition and type of photo-activating light. Therefore, 15 specimens from Filtek Supreme composite resin and 15 specimens from 4 Seasons composite resin were prepared. Both materials were polymerized with three different light devices: one halogen light and two LEDs systems. These specimens were submitted to artificial aging, initially through immersion in distilled water for 24 hours and then through exposure to ultraviolet light for 24 hours, in association with immersion in distilled water. The color mensurations were accomplished by a reflectance spectrophotometer and these mensurations, through a proper mathematical formula, allowed that the total color alteration (?E) was evaluated, for each variation, at the following period of time: after distilled water immersion (T1-T2), and after ultraviolet light exposure (T1-T3). These results were analyzed by a analysis of variance, and through this analysis it was possible to notice that: Filtek Supreme composite resin presented color alteration average (?E) statistically higher than the 4 Seasons composite resin average; the type of photopolymerization light (LED or halogen) did not define any statistical differences on color stability for both studied materials. Both materials underwent significant color alteration, both statistical and visually alterations, after the artificial aging process. / Mestre
29

Resistência á compressão de restauração de resina composta em preparos de classe II /

Cioffi, Sabrina Spinelli. January 2013 (has links)
Orientador: José Roberto Cury Saad / Banca: Marcelo Ferrarezi de Andrade / Banca: Manio de Carvalho Tiburcio / Resumo: Proposição: o presente estudo tem como objetivo avaliar a resistência à compressão de restaurações de resina composta em preparos classe II, observando o tipo de preparo que possui maior resistência à compressão permitindo obter um modelo de restauração classe II com características adequadas, garantindo a qualidade da restauração, assim como sua durabilidade. Material e método: os dentes foram divididos em cinco grupos contendo oito dentes por grupo, sendo eles; Grupo 1-controle, Grupo 2- preparo mésio-oclusal com bisel, Grupo 3- preparo mesial sem canaleta e com bisel, Grupo 4- preparo mesial com canaleta e com bisel e Grupo 5- preparo mésio-oclusal sem bisel. Resultado: os resultados obtidos mostraram que o grupo controle obteve os maiores valores porém não foi estatisticamente significante quando comparado com os Grupos 2 e 5. Conclusão: preparos com extensão para oclusal apresentam valores satisfatórios porém devemos considerar que preparos preventivos não obtiveram diferença estatística quando comparados a esses preparos podendo ser indicados em casos de lesões de cárie apenas proximais. / Abstract: Objective: The present study aims to evaluate the compressive strength of composite resin restorations in Class II preparations, noting the type of preparation that has greater compressive strength allowing to obtain a Class II restoration model with appropriate characteristics, ensuring the quality of restoration, as well as its durability. Methods: The teeth were divided into five groups containing eight teeth each group; Group 1- control, Group 2- mesio-occlusal preparation with bevel; Group 3- mesial preparation without groove and with bevel; Group 4- mesial preparation with groove and bevel; Group 5- mesio-occlusal preparation without bevel. Results: The results showed that the control group had higher values but not statistically significant when compared with Groups 2 and 5. Conclusion: Preparations with occlusal extension exhibited satisfactory values but we must consider that preventive preparations did not obtain satatistical difference when compared to these preparations and may be indicated in cases of only proximal carious lesions. / Mestre
30

Avaliação difratográfica da microestrutura de três resinas compostas submetidas à aplicação de um agente clareador a base de peróxido de hidrogênio / Difractiography evaluation of three dental composites subjected to a bleaching agent-based hydrogen peroxide

Rodrigo Rocha Maia 26 March 2008 (has links)
A odontologia moderna utiliza métodos e técnicas ultraconservadores no intuito de corrigir os diversos tipos de alterações cromáticas observadas clinicamente. Os meios empregados baseiam-se na utilização de substâncias químicas à base de peróxidos presentes em diversas concentrações. O presente estudo objetivou avaliar a microestrutura de três resinas compostas fotossensíveis submetidas à aplicação de um agente clareador a base de peróxido de hidrogênio a 35% (Whiteness HP Maxx - fabricante: FGM), ativado por uma fonte híbrida de energia luminosa (Aparelho de Laser-Led Whitening Lase, fabricante: DMC). Para isso, foram confeccionados 30 corpos de prova (CDP) 10 para cada grupo, no formato de discos, com 13 mm de diâmetro e 2,0 mm de espessura em uma matriz de teflon e aço inox, fotoativados por um aparelho de luz halógena convencional (Optilux 401 - Demetron/UR) por 40 segundos com densidade de potência média igual a 450 mW/cm2. Os grupos foram dispostos da seguinte forma: Grupo 1 - resina microparticulada (Durafill VS - fabricante: Heraeus Kulzer); Grupo 2 - resina micro-híbrida (Esthet-X - fabricante: Dentsply); e Grupo 3 resina nanoparticulada (Filtek Supreme XT fabricante: 3M ESPE). Todos os materiais restauradores utilizados eram da cor A2. Após serem submetidos à sequência de acabamento e polimento os CDP foram armazenados por sete dias em saliva artificial, limpos em ultra-som, envelhecidos artificialmente de acordo com a norma ASTM G 154. Os CDP dos três grupos foram aleatoriamente divididos em 2 subgrupos (ST sem tratamento e CT com tratamento) e finalmente submetidos aos experimentos. Os CDP dos subgrupos 1-ST, 2- ST e 3-ST foram triturados (SPEX SamplePrep 8000-series, marca: Mixer/Mills) seguido pela verificação dos materiais por meio de um espectrômetro (marca/modelo: Shimadzu EDX 720) para certificação da ausência de elementos pertencentes ao meio de moagem e por fim foram levados a um difrator de raios-X (marca / modelo: Philips -PW 3040 -X'Celerator- 40kV; 30mA; (&#955;): CuK&#945;; 0,6; 0,2mm; 0,05 (2&#952;); 2s; 10-90 (2&#952;). Em seguida os CDP dos subgrupos 1-CT, 2- CT e 3-CT foram tratados com o peróxido de hidrogênio de acordo com o protocolo do fabricante para a fonte híbrida luminosa de energia selecionada, totalizando 9 aplicações de 10 minutos, onde eram respeitados os tempos de 3 minutos de ativação por 20 segundos de descanso, finalizando 10 minutos em cada aplicação. Mediante a este tratamento, os CDP dos subgrupos CT eram verificados e avaliados pelo mesmo método descrito anteriormente. Após interpretação gráfica, análise comparativa por meio do processamento digital das imagens no programa KS400 3.0 (Carl Zeiss Vision) e análise de concordância por cinco avaliadores calibrados utilizando um escore, pôde-se concluir que houve degradação estrutural e que as estruturas cristalinas das resinas estudadas foram afetadas de forma distinta quando tratadas pelo peróxido de hidrogênio; onde observou-se que: Grupo 1 > Grupo 3 > Grupo 2. Foi sugerido a realização de novos estudos, relacionados à interação do peróxido de hidrogênio às resinas compostas. / Currently, to correct dental chromatic alterations, the modern dentistry science takes advantage of ultraconservative's techniques and methods. Chemical substances, in particular peroxides are used in various concentrations. The purpose of this study was to evaluate the microstructure of 3 composites resin submitted the applies of a whitening gel - hydrogen peroxide 35% (Whiteness HP Maxx, FGM) activated by a hybrid energy light (Laser-Led, Whitening Lase, DMC). Thirty composite discs (13 mm diameter x 2,0 mm thickness) were made in a teflon custom matrix and assigned to the following groups: Group 1, microfill resin (Durafill VS, Heraeus-Kulzer); Group 2, micro hybrid resin (Esthet-X, Dentsply) and Group 3, nanofill resin (Filtek Supreme XT, 3M ESPE). Samples were light cured with an Optilux 401 (Demetron/UR) for 40s by irradiation powers about 450 mW/cm2. All samples were prepared using shade A2, followed by finishing and polishing procedures. Then, samples were stored in artificial saliva for seven days, ultra-sonicated and submitted an artificial aged (ASTM G 154). After that, each group was randomly divided in two sub-groups: ST Without treatment and CT- With treatment. The ST samples of groups 1, 2 and 3 were triturate using a grinder (SPEX SamplePrep 8000-series, Mixer/Mills), and then the materials were evaluated with a spectroscopy microscope (Shimadzu EDX 720) to verify the absence of milling particles, and a X-ray diffraction patterns were recorded using Philips - PW 3040 -X'Celerator- 40kV; 30mA; (&#955;): CuK&#945;; 0,6; 0,2mm; 0,05 (2&#952;); 2s; 10-90 (2&#952;).The CT samples of group 1, 2 and 3 were treated with hydrogen peroxide following the manufacturer protocols 9 sequential 10 minutes applications/time, totaling 90 minutes. Triturated and evaluated using the same method described above. Comparative analysis by means of image processing software KS400 3.0 (Carl Zeiss Vision), graphic interpretation and agreement analysis by five valuators calibrated using a score of the results shown degree of crystallinity of the tested composites changed by bleaching treatment. After a comparative analysis, Group 1 demonstrated more degradation followed by group 3 and group 2. New studies are necessary to define the exact interaction between composite resin and hydrogen peroxides.

Page generated in 0.0691 seconds