• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 180
  • 11
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 197
  • 197
  • 99
  • 98
  • 69
  • 55
  • 42
  • 38
  • 23
  • 23
  • 22
  • 22
  • 20
  • 19
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Influência de bebidas e escovação nas propriedades físicas de uma resina composta / Influence of beverages and brushing on the physical properties of a composite resin

Lepri, Cesar Penazzo 23 January 2009 (has links)
Objetivo: Este estudo avaliou a influência de bebidas e escovação na estabilidade de cor, rugosidade superficial e microdureza em profundidade de uma resina composta. Materiais e Método: 120 discos (10mm de diâmetro X 2mm de espessura) de resina composta (Filtek- Z250) foram preparados e polidos após 24 horas. A cor inicial e a rugosidade superficial inicial foram mensuradas e os espécimes foram divididos aleatoriamente em quatro grupos (vinho tinto, refrigerante, aguardente, ou saliva artificial controle) e três subgrupos (sem escovação; escovação com Colgate, ou escovação com Close Up Whitening). Os espécimes foram imersos na sua respectiva solução, 5x ao dia, por 5 minutos, durante 30 dias, sendo dois subgrupos escovados ao final de cada dia (120 movimentos/dia). A cor foi mensurada no 15º e no 30º dia de imersão; a rugosidade superficial final foi medida no 30º dia. Após o período de imersão, os espécimes foram armazenados em saliva artificial por 7 dias, quando a superfície dos mesmos foi polida e imediatamente realizou-se uma mensuração de cor. A alteração de cor foi mensurada com um espectrocolorímetro e analisada pelos valores de ΔE, ΔL, Δa, e Δb. Os valores de rugosidade (Ra-μm) foram medidos com um rugosímetro. Com relação à microdureza, os espécimes primeiramente foram incluídos em resina de poliéster e seccionados no sentido transversal. Após o polimento destas superfícies, foram realizadas mensurações nas profundidades de 30μm, 60μm, 90μm, 120μm e 250μm, empregando os parâmetros 25gf/40s de microdureza Knoop. Os dados foram submetidos à ANOVA e teste de Fisher\'s (α=5%). Resultados: Os valores de alteração de cor foram estatisticamente diferentes após a imersão nas bebidas; o vinho tinto promoveu a maior alteração, seguido pelo refrigerante e aguardente, que foram similares entre si e diferentes da saliva artificial. Nenhuma diferença foi observada com ou sem escovação, independentemente do dentifrício utilizado. Ao 30º dia, os espécimes apresentaram uma mudança de cor mais intensa do que ao 15º dia, após o repolimento, a cor dos espécimes foi similar à cor do 15º dia. As bebidas e a escovação influenciaram negativamente na rugosidade da superfície. Em relação à microdureza, não houve diferença significativa entre os grupos, independentemente da profundidade analisada. Conclusões: A mudança de cor da resina composta foi influenciada apenas pelas bebidas; a escovação não afetou a propriedade analisada. O repolimento não foi suficiente para promover o retorno da cor dos espécimes aos valores iniciais. A rugosidade superficial foi influenciada negativamente tanto pelas bebidas quanto pela escovação. Para a microdureza, a resina composta apresentou resultados similares independentemente das bebidas utilizadas e da presença ou ausência de escovação nos espécimes avaliados. / Objective: This study evaluated the influence of beverages and brushing on the color change, surface roughness and microhardness in depth of a composite resin. Methods: 120 composite resin disks (10mm-øX2mm-thickness; Filtek-Z250) were prepared and polished after 24h. Initials color and surface roughness were measured and specimens were randomly assigned into four groups (red wine, soft drink, sugar cane spirit, or artificial saliva control) and three subgroups (without brushing; brushing with Colgate, or brushing with Close Up Xtra Whitening). Specimens were immersed in the beverage 5x/day, for 5 minutes, over 30 days, being two subgroups brushed at the end of every day (120 moving/day). Color was measured at the 15th and 30th days of immersion; final surface roughness was measured at the 30th day. After the immersion period, specimens were stored in artificial saliva for 7 days, when their surfaces were repolished and immediately assessed by color. Color change was measured with a spectrocolorimeter and analyzed by ΔE, ΔL, Δa, and Δb values. The values of roughness (Ra - μm) were measured with a rugosimeter. As regard microhardness, the specimens were firstly included in polyester resin and sectioned in the transverse direction. After polishing these surfaces, measurements were realized at depths of 30μm, 60μm, 90μm, 120μm and 250μm, employing the parameters 25gf/40s of microhardness Knoop. Data were submitted to ANOVA and Fisher\'s tests (α=5%). Results: Color change values were statistically different after immersion in the beverages; red wine promoted the highest alteration, followed by soft drink and sugar cane spirit, which presented similar results among them and different from saliva. No difference was observed with or without brushing independently of the toothpaste used. At 30th day, specimens exhibited a color change higher than 15th day; after repolishing, the color of the specimens was similar to 15th day. Beverages and brushing negatively influenced the surface roughness. In relation to microhardness, there was no significant difference among groups, regardless of the depth examined. Conclusions: Color change of the composite resin was influenced only by the beverages and brushing did not affect the analyzed property. The repolishing was not sufficient to promote the return of the specimens color to their initial values. The surface roughness was negatively influenced both by the beverage as brushing. For microhardness, the composite resin showed similar results regardless of the beverages used and the presence or absence of brushing in the specimens tested.
42

Resistência adesiva ao cisalhamento de reparos em porcelana condicionada com laser / Shear bond strenght of porcelain repairs etched with laser

Pedrazzi, Hamilton 26 November 2007 (has links)
O objetivo foi avaliar in vitro a resistência ao cisalhamento de reparos em porcelana condicionada com laser e compará-la aos tradicionais métodos de reparo condicionados com ácido hidrofluorídrico e ácido fosfórico. Neste estudo, foram utilizados dois condicionadores químicos de porcelana (ácido hidrofluorídrico a 10% - Dentsply; ácido fosfórico a 37% - 3M ESPE), um agente silano (Rely X Silano - 3M ESPE), um sistema adesivo (Scotchbond Multi-uso - 3M ESPE), um compósito restaurador (Filtek Z250 - 3M ESPE), uma porcelana odontológica (Ceramco 3 - Dentsply) e um laser de alta potência em regime de femtosegundo (Ti:Safira - Libra- S, Coherent). Sessenta pastilhas em porcelana foram confeccionadas e incluídas e anéis de PVC com resina acrílica quimicamente ativada. As pastilhas de porcelana foram polidas com lixas abrasivas em ordem decrescente de abrasividade para o aplainamento da superfície. Foram formados 6 Grupos (n=10) assim divididos: G1 - condicionamento com laser com potência 760mW; G2 - condicionamento com laser com potência de 760mW e aplicação de ácido fosfórico a 37% por 15s; G3: condicionamento com laser com potência de 900mW; G4 - condicionamento com laser com potência de 900mW e aplicação de ácido fosfórico a 37% por 15s; G5 - aplicação de ácido fosfórico 37% por 15s (grupo controle) e G6 - aplicação de ácido fluorídrico a 10% por dois minutos. Após o condicionamento da porcelana, foi aplicado agente silano para todos os corpos de prova, seguido da aplicação do sistema adesivo e polimerização por 20s. Foram confeccionados corpos de prova de resina composta na superfície da porcelana com a inserção de camadas através de matriz bipartida e de maneira incremental (2 incrementos), com fotopolimerização de 20 segundos por incremento, utilizando aparelho fotopolimerizador (XL 3000, 3M Dental Products). Em seguida a matriz foi removida e os anéis de resina com os corpos-de-prova confeccionados removidos do porta matriz e submetidos à nova fotopolimerização por mais 20 segundos. Depois de confeccionados os corpos-deprova foram levados á máquina de termociclagem por 1000 ciclos de 30 segundos em cada banho com temperatura entre 5ºC e 55ºC. Após a termociclagem os corpos-de-prova foram submetidos ao ensaio de cisalhamento. Os resultados foram avaliados estatisticamente por análise de variância (ANOVA 1 fator de variação) e teste de Tuckey (alfa=0,05). As médias e desvio padrão foram: G1 - 11,25 ± 3,10(ab); G2 - 12,32 ± 2,65(ab); G3 - 14,02 ± 2,38(a); G4 - 13,44 ± 2,07(a); G-5 - 9,91 ± 2,18(b); G6 - 12,74 ± 2,67(ab), (letras iguais demonstram não haver diferença entre grupos). / The aim of this study was to evaluate in vitro the shear bond strength of repairs in porcelain conditioned with laser and to compare it to the traditional repair methods conditioned with hydrofluoric acid and phosphoric acid. In this study, were used two conditioning porcelain (10% hydrofluoric acid - Dentsply; 37% phosphoric acid - 3M ESPE), a silane agent (Rely X Silano - 3M ESPE), an adhesive system (Scotchbond Multi-uso - 3M ESPE), a composite resin (Filtek Z250 - 3M ESPE), a porcelain (Ceramco 3 - Dentsply) and a laser of high potency in femtosecond (Ti:Safira Libra-S, Coherent). Sixty porcelain discs were made and embedded in PVC rings using a polymethyl methacrylate resin. All specimen were smoothed with abrasive sandpapers in decreasing order of abrasiveness for the leveling of the surface. Six Groups were formed (n=10) being divided: G1 - conditioning with laser with potency 760mW; G2 - conditioning with laser with potency of 760mW and application of 37% phosphoric acid for 15s; G3: conditioning with laser with potency of 900mW; G4 - conditioning with laser with potency of 900mW and application of 37% phosphoric acid for 15s; G5 - application of 37% phosphoric acid for 15s (group control) and G6 - application of 10% hydrofluoric acid for two minutes. After the conditioning of the porcelain, silane agent was applied for all of the specimens, following by the application of the adhesive system and photoactivation for 20s. Specimens of composed resin were made in the surface of the porcelain aided with a metal matrix and insert of incremental layers (2 increments) with photoactivation of 20 seconds for increment. The photoactivation was performed with a visible light unit (XL 3000, 3M Dental Products). Afterwards the metal matrix was removed and the specimens were submitted to the new photoactivation for more 20 seconds. The specimens were submitted a thermal cycling by 1000 cycles of 30 seconds in each bath with temperature between 5ºC and 55ºC. After the thermal cycling , specimens were submitted to the shear bond strength. The results were evaluated statistically through analysis of variance - ANOVA One Way and Tuckey test (alfa=0,05). The averages and standard deviation: G1 - 11,25 ± 3,10(ab); G2 - 12,32 ± 2,65(ab); G3 - 14,02 ± 2,38(a); G4 - 13,44 ± 2,07(a); G-5 - 9,91 ± 2,18(b); G6 - 12,74 ± 2,67(ab), (same letters demonstrate there not to be difference among groups).
43

Desenvolvimento de tensões de polimerização determinado através do método da propagação de trincas / Development also polymerization stress determined by crack analysis methods

Guimarães, Thayse da Costa 30 August 2013 (has links)
O objetivo do presente estudo foi avaliar o desenvolvimento das tensões de polimerização de um compósito resinoso restaurador ao longo das primeiras 24 horas após a fotoativação, segundo dois métodos de análise da propagação de trincas. A influência do armazenamento em água sobre a magnitude das tensões também foi avaliada. O grau de conversão (GC) e o módulo de elasticidade (E) do compósito foram determinados nos diferentes tempos de observação. As hipóteses nulas do trabalho foram: 1) tensão de polimerização, GC e E não variam de forma significativa ao longo do período de observação; 2) os dois métodos de análise de propagação de trincas fornecem resultados semelhantes; 3) os valores de tensão não são influenciados pelo meio de armazenamento. Foram confeccionados discos de vidro de soda-cal com 2 mm de espessura, diâmetro externo de 12 mm, com perfuração central de 4 mm de diâmetro. Os discos foram aleatorizados em três grupos. Em um deles, os discos foram restaurados (Charisma Diamond, Heraeus Kulzer) e, após os tempos de 10 min, 1, 2, 4, 8 ou 24 horas (n=10), os espécimes receberam quatro indentações Vickers, (9,8N por 20s) a 500m da margem da cavidade. O segundo grupo passou pelo mesmo processo, porém os discos ficaram armazenados em água antes de serem indentados. Em seguida, o comprimento das trincas e a diagonal da indentação foram mensurados em microscópio óptico. A tensão residual no vidro foi calculada de acordo com a norma 4-01 (The Society of Materials Science, JSMS, Japão). No terceiro grupo, os discos foram indentados e armazenados em dissecador por 24h antes de serem restaurados. As trincas foram medidas antes e após a restauração, nos mesmos tempos descritos acima, e a tensão calculada de acordo com a fórmula descrita por Yamamoto et al. (Dent Mater, 2009). O GC foi determinado por espectroscopia no infra-vermelho próximo (n=3). O E foi obtido através do teste de dobramento em três pontos (n=10). Os dados foram submetidos a ANOVA/Tukey (=0,05) e análise de regressão. A tensão de polimerização, assim como o GC e o E tiveram seus valores aumentados ao longo do tempo. O GC aumentou 28% entre 10 minutos e 24 horas, para o E houve um aumento de 1,7 GPa para 6,3 GPa entre 10 minutos e 24 horas. A tensão de polimerização aumentou 40% entre 10min e 24h para a norma 4-01 e 51% para o método do Yamamoto et al. O meio de armazenamento foi estatisticamente significativo até o tempo de 4 horas. Portanto, a primeira hipótese foi rejeitada. A segunda e a terceira hipótese podem ser apenas parcialmente rejeitadas. / The objective of this study was to evaluate composite resin restoration polymerization stress development over the first 24 hours after polymerization, according to two methods of analysis of crack propagation. The influence of water storage on the magnitude of the stresses was also evaluated. The degree of conversion (DC) and modulus of elasticity (E) of the composite were determined at various time points. The null hypotheses of this study were: 1) The polymerization stress, DC and E do not change significant throughout the observation period, 2) the two methods of analysis of crack propagation provide similar results, 3) the stress values are not influenced by storage medium. Disks were made of soda-lime glass with 2 mm thickness, 12 mm in outside diameter with central bore of 4 mm in diameter. The perforations were treated with hydrofluoric acid and silane. The discs were randomized into three groups. In one of them, the discs were restored (Charisma Diamond, Heraeus Kulzer), and, the times after 10 min, 1, 2, 4, 8 or 24 hours (n = 10), the specimens received four Vickers indentations (9.8 N for 20 s) at 500m cavity margin. The second group went through the same process, but the discs were stored in water prior to being indented. Then, the length diagonal of the indentation and crack was measured in an optical microscope. The residual stress in the glass was calculated according to standard 4-01 (The Society of Materials Science, JSMS, Japan). The third group of discs were treated similarly, indented and stored in a desiccator for 24 hours before being restored. The cracks were measured before and after the restoration following the same time, and the stress calculated according to the formula described by Yamamoto et al. (Dent Mater, 2009). The DC was determined by near-infrared spectroscopy (n = 3). The E was obtained through the bend test conducted at three-points. Data were subjected by ANOVA / Tukey test ( = 0.05) and regression analysis. The polymerization stress, as well as DC and E values were increased over time. GC increased 28% between 10 minutes and 24 hours, and for an increase of 1.7 GPa to 6.3 GPa between 10 minutes and 24 hours. The polymerization stress increased 40% between 10 min and 24 hours to the standard 4.1 and 51% for the method of Yamamoto et al. The storage medium was statistically significant at the time of 4 hours. Thus, the first hypothesis was rejected. The second and third hypothesis may only be partially rejected.
44

Alteração de cor e rugosidade superficial de resina composta clareada após envelhecimento em função do tempo / Color change and surface roughness of composite resin cleared after accelerated artificial aging as a function of time

Freitas, Daniela de Biagi 30 July 2010 (has links)
O presente trabalho teve como objetivo analisar “in vitro” a alteração de cor e a rugosidade superficial de uma resina composta (Charisma®) submetidas a tratamento clareador com agente clareador Lase Peroxide Sensy® (CC) e grupo controle sem tratamento clareador (SCL), após envelhecimento (EAA) em função do tempo, realizando-se avaliação superficial complementar por meio de Microscopia Eletrônica de Varredura (MEV) e EDX. Os corpos-de-prova (n=15) foram confeccionados com o auxílio de uma matriz de Teflon nas dimensões de 11x2,0mm, polidos com discos Soft Lex®, na seqüência de abrasividade decrescente e armazenados em saliva artificial a 37ºC (±1ºC), até os momentos de serem submetidos aos tratamentos propostos e à realização das leituras de alteração de cor e rugosidade superficial, nos tempos: 24 horas após a confecção (T0), após envelhecimento artificial acelerado (T1), 24 horas após clareamento (T2), 7dias (T3) e 1 mês após clareamento (T4). As leituras de alteração de cor foram obtidas com o auxílio do aparelho Espectrofotômetro (PCB6807BYK GARDNER) e para as leituras de rugosidade superfícial foi utilizado o Rugosímetro Mitutoyo SJ201P. Os dados foram submetidos à Análise de Variância ANOVA (p≤0,05). Os resultados obtidos foram: a) o fator Tempo teve efeito estatisticamente significante sobre as variáveis ΔE* (T1=T2=T3; T1=T4), L* (T0<T1=T2=T3=T4), a* (T0>T1=T2; T1=T3=T4; T4>T2), b* (T0>T1=T2=T3; T4=T3=T1; T2<T4) e rugosidade superficial (μm) (T0<T1,T2,T3,T4; T1=T2; T1<T3=T4; T2=T3=T4; b) para o fator tratamento com relação a ΔE* e fator L*(CC>SCL), para os fatores a* e b*(CC<SC), c) a interação Tratamento x Tempo não apresentou diferença estatisticamente significante para as variáveis ΔE*, L*, a*, b* e rugosidade superficial, d) as superfícies após EAA apresentaram alterações d) não houve mudanças no EDX antes e após os tratamentos. Conclui-se que a resina Charisma®, apresentou alteração de cor (ΔE*>3,3) e uma estabilidade na rugosidade superficial a partir de T2. / The current study in vitro evaluated the color change and surface roughness of the composite resin Charisma® cleared with Lase Peroxide Sensy® (CCL) and control without bleaching (SCL) after accelerated artificial aging (EAA) as a function of time, performing additional surface evaluation by scanning electron microscopy (MEV) and EDX. To obtain the color change and surface roughness a Spectrophotometer (PCB 6807 BYK GARDNER) and rugosimeter (Mitutoyo SJ- 201P) were employed respectively. Measurements were carried out at five times: 24 hours after preparation (T0), after artificial accelerated aging (T1), 24 hours after bleaching (T2), 7days (T3) and 1 month after bleaching (T4). The specimens (n=15) were prepared with aid of a Teflon (10-mmin diameter and 2mm thick). The specimens were polished with discs Soft Lex®, following abrasiveness decreased, being stored in artificial saliva at 37ºC (±1ºC) until the time of undergoing the proposed treatments and the measurements. The data obtained were submitted to ANOVA parametric test (p ≤ 0.05). The results were: a) time factor had a statistically significant effect on the variables ΔE* (T1 = T2 = T3, T1 = T4), L*(T0 <T1 = T2 = T3 = T4), a* (T0 > T1 = T2; T1=T3 =T4, T4>T2), b* (T0> T1=T2=T3, T4=T3=T1; T2<T4) and roughness(μm) (T0<T1,T2, T3,T4; T1 = T2; T1<T3=T4; T2=T3=T4), b) for treatment factor ΔE* and L* (CC> SCL) for the factors a*and b* (CC <SC), c) Treatment x Time interaction showed no statistically significant difference for the variables ΔE*, L*, a*, b* and surface roughness, d) after EAA the surfaces change d) before and after EAA dont have changes. It is concluded that the resin Charisma®, presented color change (ΔE *> 3.3) and surface roughness stability from T2.
45

Análise da estabilidade de cor e rugosidade de superfície de compósitos submetidos à fumaça de cigarro / Color stability and surface roughness of dental composites exposed to cigarette smoke

Román, Carla Cecília Alandia 29 November 2011 (has links)
O objetivo deste estudo foi avaliar a estabilidade de cor e rugosidade de superfície de 3 compósitos odontológicos com partículas diferentes: nanohíbrido (Tetric N-Ceram - Ivoclar Vivadent), híbrido (Z250 - 3M ESPE) e microhíbrido com matriz silorano (Filtek P90 3M - ESPE), submetidos à fumaça de cigarro. Para isso, foram obtidos 60 corpos-de-prova (8mm de diâmetro X 2mm de espessura), 20 para cada tipo de material restaurador utilizado, dos quais 10 receberam polimento com lixas dágua em abrasividades decrescentes (Grupo1) e a outra metade não foi submetida a nenhum tipo de acabamento/polimento ficando sob efeito apenas de uma matriz de poliéster (Grupo 2). Após armazenamento dos corpos de prova em água destilada a 37°C por 24 horas, foram realizadas as primeiras leituras de cor (Colorímetro Vita Easy Shade) na escala de cor CIEL*a*b* e rugosidade superficial (Rugosímetro Surfcorder SE 1700 - Kosakalab). Em seguida, as amostras foram expostas à fumaça de 20 cigarros por um período de 10 minutos cada, (Marlboro - Philip Morris), sendo que entre um cigarro e outro as amostras foram submetidas à escovação em dispositivo padronizado e lavagem em água corrente. Após ação do número total de cigarros, foram realizadas leituras finais de cor e rugosidade. Os valores de &Delta;E, &Delta;L, &Delta;a e &Delta;b foram analisados estatisticamente utilizando 2 way ANOVA e Teste de Bonferroni (p<0.05) e os valores de rugosidade média (Ra) foram analisados isoladamente para cada tipo de material (teste t Student, p < 0.05). Verificou-se que o compósito Tetric N apresentou maior alteração de cor, em níveis clinicamente inaceitáveis (&Delta;E>3,3) e de rugosidade de superfície em relação aos demais compósitos quando utilizada a tira de poliéster como acabamento. Concluiu-se que a ausência de polimento aumenta a capacidade manchadora do cigarro sobre todos os compósitos e a rugosidade de superfície dos materiais, com exceção de P90. / The purpose of this study was to evaluate the color stability and surface roughness of three dental composites with different type of fillers: Nanohybrid (Tetric N-Ceram), Hybrid (Filtek Z250-3M ESPE) and Microhybrid silorane based composite (Filtek P90- 3M ESPE), exposed to cigarette smoke. 20 specimens (8mm diameter X 2mm thickness) of each material were prepared and separated into two groups (n=10) according to the surface treatment : Group 1- polymerization through a polyester film strip and polishing with water sandpaper in decreasing abrasiveness (600, 800 e 1200); and Group 2- polymerization through a polyester film strip, without any polishing. After immersion in destilled water 37° for 24 hours, baseline color of all specimens was measured using reflectance spectrophotometer (Easy Shade - Vita) with CIEL*a*b* system, surface roughness was also measured using a rugosimeter (SJ-201P Mitutoyo, Tokyo, Japan). After base line measurements, the specimens were exposed to smoke from 20 cigarettes in 10 minutes each, (Marlboro - Philip Morris), between one cigarette and other, the specimens were submitted to brushing in a standardized device and washed with water. After the action of the total number of cigarettes, final measurements of color and surface roughness were performed. Values of &Delta;E, &Delta;L, &Delta;a e &Delta;b were statistically analyzed using 2 way ANOVA e Teste de Bonferroni (p<0.05) and values of average surface roughness (Ra) were analyzed separately for each type of material (teste t Student, p < 0.05). It was found that the composite Tetric N-Ceram showed increased of surface roughness and greater color change in clinically unacceptable levels (&Delta;E>3,3), in comparison with the other composites when used the polyester strip without polishing. It was concluded that the absence of polishing increases the cigarette staining and surface roughness on all composites except for Filtek P90.
46

Liberação de Bisfenol A de sistemas adesivos resinosos ortodônticos por meio de cromatografia gasosa - Estudo in vitro e in vivo / Release of bisphenol A resinous orthodontic adhesives by gas chromatography. In vitro and In vivo study

Moreira, Marilia Rodrigues 19 March 2015 (has links)
O objetivo deste trabalho foi avaliar a liberação de Bisfenol A (BPA) de sistemas adesivos resinosos ortodônticos in vitro e in vivo. No estudo in vitro foram testadas 5 marcas comerciais de sistemas adesivos resinosos ortodônticos (Eagle Spectrum, Enlight, Light Bond, Mono Lok II e Transbond XT). Por meio da simulação de exposição intraoral, os corpos de prova foram imersos numa solução água/etanol e a liberação de BPA foi medida nos tempos de 30 minutos, 24 horas, 1 dia, 1 semana e 1 mês. No estudo in vivo utilizou-se amostra composta por 20 pacientes com indicação para tratamento ortodôntico com aparelhos fixos. Foram coletadas amostras de saliva em 5 tempos: antes, 30 minutos, 24 horas, 1 dia, 1 semana e 1 mês após a colagem dos bráquetes e as de urina em 4 tempos: antes, 1 dia, 1 semana e 1 mês após a colagem. Todos os compósitos avaliados liberaram pequena quantidade de BPA, sendo que o compósito Enlight-ORMCOR foi o que apresentou maior liberação,1020 ng/g no tempo de 1 mês. Os maiores níveis de BPA na saliva, foram encontrados no tempo de 30 minutos (1,0445 ng/mL) e na urina, 24 horas (5,035 ng/mL) após a colagem dos bráquetes. Mesmo que as quantidades de BPA liberadas fossem pequenas, houve diferença significativa quando esses valores foram comparados com os níveis iniciais, sugerindo aumento da quantidade de BPA no organismo com a colagem dos bráquetes ortodônticos. Como a literatura especializada têm destacado os potenciais tóxicos do BPA e têm sugerido alterações celulares \"com baixas\" doses, mais estudos são necessários para se chegar a um consenso no sentido de propiciar segurança no uso desses materiais. / The purpose of this study was measure the release of Bisphenol A (BPA) from the orthodontic resinous adhesive systems in vitro and in vivo. The study was divided into two stages: At in vitro study, five trademarks of Resinous Adhesive Systems (Eagle Spectrum, Enlight, Light Bond, Mono Lok II and Transbond XT) was tested. The samples were immersed in a water/ethanol solution simulating the intraoral exposition and the release of BPA was measured at times of 30 minutes, 24 hours, 1 day, 1 week and 1 month. At in vivo study, 20 patients with indication to fixed orthodontic appliances were used. Samples of saliva and urine were collected in these patients at previously determined time. To the saliva, it was collected 5 times ( before bonding the orthodontic brackets and 30 minutes, 24 hours, 1 day, 1 week and 1 month after this procedure); to the urine, it was collected 4 times ( before, 1 day, 1 week, 1 month, after bonding the orthodontic brackets). All the tested resinous adhesives released a small quantity of BPA, with peack at 1 month, with Enlight resinous presenting the highest level (1020 ng/g). The peack level in saliva (130445 ng/ml) and urine (5.035 ng/ml) were found in 30 minutes and 24 hours after the bonding of fixed appliances, respectively. However the quantities of released BPA are small which validate the security of the procedure. A significant difference was observed when these values were compared to the initial levels, suggesting a correlation of the increase of the quantity of BPA in the body and the bonding of the orthodontic appliances. As several studies have reported, the probable toxic effect of BPA and cellular changes in \"low doses\", more studies are necessary to reach a consensus. to provide security in the use of such materials.
47

Resistência adesiva ao cisalhamento de reparos em porcelana condicionada com laser / Shear bond strenght of porcelain repairs etched with laser

Hamilton Pedrazzi 26 November 2007 (has links)
O objetivo foi avaliar in vitro a resistência ao cisalhamento de reparos em porcelana condicionada com laser e compará-la aos tradicionais métodos de reparo condicionados com ácido hidrofluorídrico e ácido fosfórico. Neste estudo, foram utilizados dois condicionadores químicos de porcelana (ácido hidrofluorídrico a 10% - Dentsply; ácido fosfórico a 37% - 3M ESPE), um agente silano (Rely X Silano - 3M ESPE), um sistema adesivo (Scotchbond Multi-uso - 3M ESPE), um compósito restaurador (Filtek Z250 - 3M ESPE), uma porcelana odontológica (Ceramco 3 - Dentsply) e um laser de alta potência em regime de femtosegundo (Ti:Safira - Libra- S, Coherent). Sessenta pastilhas em porcelana foram confeccionadas e incluídas e anéis de PVC com resina acrílica quimicamente ativada. As pastilhas de porcelana foram polidas com lixas abrasivas em ordem decrescente de abrasividade para o aplainamento da superfície. Foram formados 6 Grupos (n=10) assim divididos: G1 - condicionamento com laser com potência 760mW; G2 - condicionamento com laser com potência de 760mW e aplicação de ácido fosfórico a 37% por 15s; G3: condicionamento com laser com potência de 900mW; G4 - condicionamento com laser com potência de 900mW e aplicação de ácido fosfórico a 37% por 15s; G5 - aplicação de ácido fosfórico 37% por 15s (grupo controle) e G6 - aplicação de ácido fluorídrico a 10% por dois minutos. Após o condicionamento da porcelana, foi aplicado agente silano para todos os corpos de prova, seguido da aplicação do sistema adesivo e polimerização por 20s. Foram confeccionados corpos de prova de resina composta na superfície da porcelana com a inserção de camadas através de matriz bipartida e de maneira incremental (2 incrementos), com fotopolimerização de 20 segundos por incremento, utilizando aparelho fotopolimerizador (XL 3000, 3M Dental Products). Em seguida a matriz foi removida e os anéis de resina com os corpos-de-prova confeccionados removidos do porta matriz e submetidos à nova fotopolimerização por mais 20 segundos. Depois de confeccionados os corpos-deprova foram levados á máquina de termociclagem por 1000 ciclos de 30 segundos em cada banho com temperatura entre 5ºC e 55ºC. Após a termociclagem os corpos-de-prova foram submetidos ao ensaio de cisalhamento. Os resultados foram avaliados estatisticamente por análise de variância (ANOVA 1 fator de variação) e teste de Tuckey (alfa=0,05). As médias e desvio padrão foram: G1 - 11,25 ± 3,10(ab); G2 - 12,32 ± 2,65(ab); G3 - 14,02 ± 2,38(a); G4 - 13,44 ± 2,07(a); G-5 - 9,91 ± 2,18(b); G6 - 12,74 ± 2,67(ab), (letras iguais demonstram não haver diferença entre grupos). / The aim of this study was to evaluate in vitro the shear bond strength of repairs in porcelain conditioned with laser and to compare it to the traditional repair methods conditioned with hydrofluoric acid and phosphoric acid. In this study, were used two conditioning porcelain (10% hydrofluoric acid - Dentsply; 37% phosphoric acid - 3M ESPE), a silane agent (Rely X Silano - 3M ESPE), an adhesive system (Scotchbond Multi-uso - 3M ESPE), a composite resin (Filtek Z250 - 3M ESPE), a porcelain (Ceramco 3 - Dentsply) and a laser of high potency in femtosecond (Ti:Safira Libra-S, Coherent). Sixty porcelain discs were made and embedded in PVC rings using a polymethyl methacrylate resin. All specimen were smoothed with abrasive sandpapers in decreasing order of abrasiveness for the leveling of the surface. Six Groups were formed (n=10) being divided: G1 - conditioning with laser with potency 760mW; G2 - conditioning with laser with potency of 760mW and application of 37% phosphoric acid for 15s; G3: conditioning with laser with potency of 900mW; G4 - conditioning with laser with potency of 900mW and application of 37% phosphoric acid for 15s; G5 - application of 37% phosphoric acid for 15s (group control) and G6 - application of 10% hydrofluoric acid for two minutes. After the conditioning of the porcelain, silane agent was applied for all of the specimens, following by the application of the adhesive system and photoactivation for 20s. Specimens of composed resin were made in the surface of the porcelain aided with a metal matrix and insert of incremental layers (2 increments) with photoactivation of 20 seconds for increment. The photoactivation was performed with a visible light unit (XL 3000, 3M Dental Products). Afterwards the metal matrix was removed and the specimens were submitted to the new photoactivation for more 20 seconds. The specimens were submitted a thermal cycling by 1000 cycles of 30 seconds in each bath with temperature between 5ºC and 55ºC. After the thermal cycling , specimens were submitted to the shear bond strength. The results were evaluated statistically through analysis of variance - ANOVA One Way and Tuckey test (alfa=0,05). The averages and standard deviation: G1 - 11,25 ± 3,10(ab); G2 - 12,32 ± 2,65(ab); G3 - 14,02 ± 2,38(a); G4 - 13,44 ± 2,07(a); G-5 - 9,91 ± 2,18(b); G6 - 12,74 ± 2,67(ab), (same letters demonstrate there not to be difference among groups).
48

Análise da estabilidade de cor e rugosidade de superfície de compósitos submetidos à fumaça de cigarro / Color stability and surface roughness of dental composites exposed to cigarette smoke

Carla Cecília Alandia Román 29 November 2011 (has links)
O objetivo deste estudo foi avaliar a estabilidade de cor e rugosidade de superfície de 3 compósitos odontológicos com partículas diferentes: nanohíbrido (Tetric N-Ceram - Ivoclar Vivadent), híbrido (Z250 - 3M ESPE) e microhíbrido com matriz silorano (Filtek P90 3M - ESPE), submetidos à fumaça de cigarro. Para isso, foram obtidos 60 corpos-de-prova (8mm de diâmetro X 2mm de espessura), 20 para cada tipo de material restaurador utilizado, dos quais 10 receberam polimento com lixas dágua em abrasividades decrescentes (Grupo1) e a outra metade não foi submetida a nenhum tipo de acabamento/polimento ficando sob efeito apenas de uma matriz de poliéster (Grupo 2). Após armazenamento dos corpos de prova em água destilada a 37°C por 24 horas, foram realizadas as primeiras leituras de cor (Colorímetro Vita Easy Shade) na escala de cor CIEL*a*b* e rugosidade superficial (Rugosímetro Surfcorder SE 1700 - Kosakalab). Em seguida, as amostras foram expostas à fumaça de 20 cigarros por um período de 10 minutos cada, (Marlboro - Philip Morris), sendo que entre um cigarro e outro as amostras foram submetidas à escovação em dispositivo padronizado e lavagem em água corrente. Após ação do número total de cigarros, foram realizadas leituras finais de cor e rugosidade. Os valores de &Delta;E, &Delta;L, &Delta;a e &Delta;b foram analisados estatisticamente utilizando 2 way ANOVA e Teste de Bonferroni (p<0.05) e os valores de rugosidade média (Ra) foram analisados isoladamente para cada tipo de material (teste t Student, p < 0.05). Verificou-se que o compósito Tetric N apresentou maior alteração de cor, em níveis clinicamente inaceitáveis (&Delta;E>3,3) e de rugosidade de superfície em relação aos demais compósitos quando utilizada a tira de poliéster como acabamento. Concluiu-se que a ausência de polimento aumenta a capacidade manchadora do cigarro sobre todos os compósitos e a rugosidade de superfície dos materiais, com exceção de P90. / The purpose of this study was to evaluate the color stability and surface roughness of three dental composites with different type of fillers: Nanohybrid (Tetric N-Ceram), Hybrid (Filtek Z250-3M ESPE) and Microhybrid silorane based composite (Filtek P90- 3M ESPE), exposed to cigarette smoke. 20 specimens (8mm diameter X 2mm thickness) of each material were prepared and separated into two groups (n=10) according to the surface treatment : Group 1- polymerization through a polyester film strip and polishing with water sandpaper in decreasing abrasiveness (600, 800 e 1200); and Group 2- polymerization through a polyester film strip, without any polishing. After immersion in destilled water 37° for 24 hours, baseline color of all specimens was measured using reflectance spectrophotometer (Easy Shade - Vita) with CIEL*a*b* system, surface roughness was also measured using a rugosimeter (SJ-201P Mitutoyo, Tokyo, Japan). After base line measurements, the specimens were exposed to smoke from 20 cigarettes in 10 minutes each, (Marlboro - Philip Morris), between one cigarette and other, the specimens were submitted to brushing in a standardized device and washed with water. After the action of the total number of cigarettes, final measurements of color and surface roughness were performed. Values of &Delta;E, &Delta;L, &Delta;a e &Delta;b were statistically analyzed using 2 way ANOVA e Teste de Bonferroni (p<0.05) and values of average surface roughness (Ra) were analyzed separately for each type of material (teste t Student, p < 0.05). It was found that the composite Tetric N-Ceram showed increased of surface roughness and greater color change in clinically unacceptable levels (&Delta;E>3,3), in comparison with the other composites when used the polyester strip without polishing. It was concluded that the absence of polishing increases the cigarette staining and surface roughness on all composites except for Filtek P90.
49

Avaliação comparativa da resistência à abrasão de resinas compostas "condensáveis", submetidas à escovação simulada, através da alteração de massa e da rugosidade superficial. / "In vitro" ëvaluation of abrasion resistance of "condensable" composite resins after toothbrushing. Wear and superficial roughness analysis.

Wang, Linda 02 March 2001 (has links)
Resinas compostas "condensáveis" correspondem a uma nova categoria de material restaurador posterior especialmente desenvolvida como alternativa estética ao amálgama. O objetivo deste trabalho foi comparar algumas marcas comerciais Solitaire (So), SureFil (Su), Alert (A), Prodigy Condensable (PC) e Filtek P-60 (P-60) a dois grupos controles, Silux Plus (SP), de micropartículas, e Z100 (Z), microhíbrida, por meio de um teste in vitro de escovação simulada. Doze corpos-de-prova de cada material foram confeccionados com dimensões de 5mm de diâmetro por 3mm de espessura. Foram realizados 100.000 ciclos de escovação em uma máquina de escovação simulada, utilizando escovas dentais de cerdas macias e solução de dentifrício e água deionizada. A alteração de massa foi verificada pela diferença entre as médias de massa inicial (antes da escovação) e final (depois da escovação) em balança analítica Sartorius. A análise da rugosidade superficial em Ra foi determinada pela diferença entre as médias de cinco leituras, iniciais e finais, com um rugosímetro Hommel Tester T1000 e por meio de microscopia eletrônica de varredura. Os resultados obtidos foram submetidos à análise de ANOVA e Tukey, apresentando diferenças significantes para perda de massa e alteração de rugosidade. As resinas SureFil e Alert apresentaram menor alteração de massa (0,38% e 0,52%), enquanto Solitaire, Prodigy Condensable e Silux Plus as maiores (1,51%, 1,55%, 1,70%). Z100 e P-60 apresentaram alteração de massa intermediária às outras resinas. Diferentemente dos outros grupos, Prodigy Condensable, Solitaire e Z100 apresentaram, após a escovação, superfícies mais lisas (-0,012mm, -0,047mm e -0,065mm respectivamente), enquanto a rugosidade superficial aumentou nos demais grupos (A= 0,073mm, P-60= 0,095mm, Si= 0,158mm e Su= 0,470mm). SureFil apresentou a menor perda de massa e a maior variação de rugosidade superficial comparada às demais resinas testadas. Não houve correlação entre perda de massa e rugosidade superficial. As análises realizadas em microscopia eletrônica de varredura apresentaram-se coerentes com os resultados quantitativos obtidos. De maneira geral, as resinas compostas "condensáveis" apresentaram comportamento semelhante entre si e em relação à resina microhíbrida Z100. / "Condensable" composites resins are a category of posterior materials especially developed as an aesthetic alternative to amalgam. The aim of this research was to compare these materials by an "in vitro" abrasion test simulating toothbrushing. Solitaire (So), SureFil (Su), Alert (A), Prodigy Condensable (PC) and Filtek P-60 (P-60) were compared to two control groups, microfilleD Silux Plus (SP) and microhybrid Z100 (Z). Twelve samples of each material were prepared with 5mm in diameter and 3mm thick. The abrasion test was applied up to 100.000 cicles by an appropriate machine with soft bristles tips containing dentifrice solution and deionized water. The weight loss was detected by the differences between the initial (before toothbrushing) and the final weight (after toothbrushing) using a Sartorius analytical scale. The evaluation of surface roughness was observed by the difference between initial and final means after 5 readings in a Hommel Tester T1000 testing machine. The specimens were also analysed by SEM. The obtained results (ANOVA and Tukey) showed significant differences of weight and surface roughness between the tested materials. SureFil and Alert exhibited lower loss of weight (Su-0.38%; A-0.52%), Solitaire, Prodigy Condensable, and Silux Plus presented greatest wear(So-1.51%; PC-1.55%, SP-1.70%) while Z100 and Filtek P-60 showed intermediate loss ( Z-1.16%; P-60-1.31%). Differently to the others groups, Prodigy Condensable, Solitaire and Z-100 showed a decrease in surface roughness compared to the initial condition (-0.012mm,-0.047mm and -0.065mm respectively) which increased in the remainder groups (A) 0.073mm, P-60) 0.095mm, Si) 0.158mm and Su) 0.470mm). SureFil presented the lowest weight loss and the highest surface roughness variation comparing to the other tested resins. There was no correlation between wear and surface roughness. The SEM results were in accordance to those obtained by the Hommel Tester T1000 testing machine. "condensable" composites resins showed the same behavior compared to the microhybrid Z100 control resin.
50

Estudo in vitro do efeito de unidades fotoativadoras com diferentes comprimentos de onda na dureza (por meio de micro e ultramicroendentação) e módulo de elasticidade de uma resina composta nanohíbrida / Effect of light sources with different wavelengths in micro and ultramicrohardness and elastic modulus of a nanohybrid composite resin. An in vitro study

Araujo, Jesuina Lamartine Nogueira 04 June 2013 (has links)
Este trabalho avaliou in vitro a dureza e módulo de elasticidade de uma resina composta nanohíbrida (Tetric N-Ceram/Ivoclair-Vivadent) com diferentes cores, fotoativada por duas unidades com diferentes comprimentos de onda em 3 espessuras (1, 2 e 3mm) comparadas à partir da superfície irradiada (0mm). Os espécimes foram divididos em grupos (n=5): microdureza Knoop-KHN, ultramicrodureza-DUH e módulo de elasticidade-ME, cor (A2 e Bleach-M(BM), fotoativador LEDazul (Elipar Freeligth2/3M(750mW/25s/430-480nm(FL) e LEDazul/violeta Bluephase/Ivoclar/Vivadent (1200mW/cm²/15s/380-515nm(B15) e 30s(B30). Os espécimes foram armazenados por 24h/37ºC. Os ensaios de KHN foram realizados no HMV-2000/Shimadzu, com carga de 25gf/40s, e de DUH e ME no DUH 211S/Shimadzu com força de 10mN e tempo de espera de 0s. Foram realizadas 5 endentações na superfície irradiada (0mm) e na base das amostras (1, 2 e 3mm). A análise estatística foi realizada por ANOVA, Tukey e correlação de Pearson (p<0,01%). O teste de Pearson mostrou haver correlação direta entre a KHN e a DUH. A fonte FL promoveu maiores valores de KHN e de DUH para as duas resinas testadas; enquanto que a fonte B15, promoveu o maior valor de ME. Quanto às espessuras, 0 e 1mm apresentaram maiores valores de KHN e de DUH, e menores de ME que as espessuras de 2 e 3mm. A cor A2 apresentou maior valor de KHN e DUH e menor ME que a cor Bleach-M. Assim, de acordo com a metodologia proposta e os resultados apresentados pode-se concluir que apesar de a luz LEDazul/violeta propor uma maior eficácia na polimerização de resinas de cor clara, no tocante às propriedades avaliadas isso não foi verificado. / This study evaluated in vitro the hardness (micro and ultramicro) and elastic modulus of a nanohybrid composite resin (Tetric N-Ceram/Ivoclar-Vivadent) with different colors, light sources and thickness. The specimens were divided into groups (n=5): KHN-Knoop microhardness, DUH-nanohardness and ME-elastic modulus; colors: A2 and Bleach-M (BM); light sources: LEDblue Elipar Free light 2/3M-ESPE (750mW/cm²/ 25s/430-480nm- (FL)), LEDblue/violet Bluephase/Ivoclar-Vivadent (1.200mw/cm²/15s/380-515nm) (B15) and 30s (B30); thickness: 1mm, 2mm and 3mm, compared to the irradiated surface (0mm). Specimens were stored dry for 24hours at 37ºC after photo curing. Assays were performed at KHN in HMV-2000/ Shimadzu with load of 25gf at 40s and DUH/ME in DUH 211S/Shimadzu with force of 10mN and no hold time (0s). 5 indentations of each test were made in the surfaces opposites to the photo curing. A statistical analysis was performed by ANOVA, Tukey and Pearson correlation (p<0.01%). Pearsons Test showed a direct correlation between KHN and DUH. Comparison between KHN and ME in the studied resins indicated that the light source FL promoted higher values of KHN and DUH to both resins tested, whereas the B15 light source promoted the higher ME value. Regarding thickness 0mm and 1mm showed higher KHN and DUH and lower ME than 2 and 3mm thickness. A2 color showed higher KHN and DUH and lower ME than BM. Thus, according to the proposed methods and the presented results, the LEDblue/violet was not better for curing the light color of the nanohybrid resin, than LEDblue.

Page generated in 0.0687 seconds