• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 692
  • 426
  • 47
  • 44
  • 35
  • 31
  • 20
  • 18
  • 17
  • 11
  • 9
  • 7
  • 6
  • 5
  • 4
  • Tagged with
  • 1562
  • 1562
  • 670
  • 652
  • 395
  • 394
  • 267
  • 266
  • 260
  • 239
  • 192
  • 181
  • 173
  • 140
  • 137
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
481

Avaliação de realce tardio pela Tomografia Computadorizada em pacientes chagásicos crônicos com disfunção ventricular / Delayed enhanced computed tomography in chronic chagasic patients with ventricular dysfunction

Nackle Jibran Silva 26 June 2014 (has links)
A Doença de Chagas é uma infecção parasitária causada pelo Trypanosoma cruzi1, transmitida aos humanos principalmente pelas fezes contaminadas de insetos triatomídio. Esta patologia permanece endêmica na América Latina com grande impacto socioeconômico. O envolvimento cardíaco é a principal causa de morte, sendo que a fisiopatologia e a evolução clínica da doença não são completamente compreendidas e a estratificação de risco permanece desafiadora. A presença de disfunção miocárdica associada ou não à doença arterial aterosclerótica vem acompanhada de áreas de fibrose miocárdica e tem se mostrado como importante fator de pior prognóstico. Ressonância Magnética (RM) é um método já consagrado na detecção de fibrose miocárdica pela técnica de realce tardio (RT). Os objetivos deste trabalho foram: identificar e quantificar a área de realce tardio em pacientes com Cardiopatia Chagásica e disfunção contrátil do ventrículo esquerdo por meio da Tomografia Coronária; associar a extensão do RT pela tomografia com a FE do ventrículo esquerdo, medida pela ecocardiografia; determinar se há ou não associação da presença e extensão do realce tardio com a presença de coronariopatia significativa; determinar a presença de aterosclerose coronária neste subgrupo de pacientes chagásicos por meio do escore de cálcio; e identificar a presença de coronariopatia obstrutiva nesta população. Foram selecionados 36 pacientes com o diagnóstico confirmado de Doença de Chagas e disfunção ventricular (FE< 50%) confirmada pela ecocardiografia que respeitaram os critérios de inclusão e exclusão, e que assinaram o termo de consentimento livre e esclarecido. Todos os pacientes foram submetidos a angiotomografia coronária com a técnica de realce tardio e escore de cálcio. Todos os pacientes completaram o protocolo sem efeitos adversos com dose de radiação média de 11,17 +- 1,26 mSv e com exames interpretáveis. Observadores cegos e independentes, sem conhecimento prévio dos dados clínicos ou dos exames, realizaram análise visual e quantitativa do grau de estenose coronária, do escore de cálcio e do realce tardio. A média da idade foi de 57,5+- 8, dos quais 61,1% eram mulheres. A média da FE foi de 38,19 +- 6,91. Foram encontradas 2 lesões significativas (>50%) em 2 pacientes. A média do escore de cálcio foi de 19,06 +- 40,72. A fibrose miocárdica foi observada em 86,1% dos 36 pacientes e sua quantificação foi realizada de acordo com o esquema de segmentação miocárdica segundo a orientação da American Hear Association. A partir dos nossos achados, concluímos que, por meio da Tomografia coronária, é possível identificar áreas de fibrose miocárdica em pacientes chagásicos, que a quantidade de fibrose é inversamente proporcional à fração de ejeção ventricular esquerda (r= 0,52 p = 0,0011) e que a fibrose segue um padrão de localização específico da doença. Nossos achados permitem também inferir que a fibrose miocárdica nesse grupo de pacientes não se correlaciona à presença de obstruções coronárias, sendo o padrão de realce tardio diferente daquele observado em portadores de doença arterial coronária. Não houve correlação entre o escore de cálcio e áreas de fibrose vistas pela técnica de realce tardio (r= 0,04 p= 0,80). Desta forma, a tomografia pode ser uma alternativa à RM para a pesquisa de fibrose em pacientes chagásicos, aspecto que pode ser particularmente relevante naqueles que apresentam contraindicação formal à realização deste exame. / Chagas disease is a parasitic infection caused by Trypanosoma cruzi1. It is transmitted to humans mainly by the infected feces of triatomine insects. This pathological condition remains endemic in Latin America, posing a major socioeconomic impact on the region. Cardiac involvement is the principal cause of death of patients, given that the physiopathological mechanism and clinical evolution of the disease are not fully understood and risk stratification remains a challenge. Whether associated with arteriosclerotic vascular disease or not, the presence of myocardial dysfunction is accompanied by areas of myocardial fibrosis and has emerged as an important factor associated with poor prognosis. Magnetic resonance (MR) imaging is a well-established method of detecting myocardial fibrosis by the delayed enhancement (DE) technique. Objectives: The objectives of this thesis are to identify and quantify DE areas on left ventricular contractile dysfunction patients with chagasic cardiopathy using coronary tomography, to associate tomography DE extension with left ventricular ejection fraction (EF) measured by echocardiography, to determine whether the presence and extension of DE are associated with the presence of significant coronaropathy, and to identify the presence of obstructive coronaropathy in chagasic patients. Background: Methods: Thirty six patients with confirmed Chagas disease and ventricular dysfunction diagnosis (EF < 50%), as verified by echocardiography. All the patients underwent coronary computed tomographic (CT) angiography using DE technic. All the patients successfully completed the protocol with a mean radiation dose of 11.17 1.26 mSv, without adverse effects and undergoing measurable tests. Independent observers blinded to the clinical data or examinations of the patients performed visual and quantitative analyses of the degree of coronary stenosis, and DE. Results: The mean age was 57.5 8 years, and 61.1% of them were female. The mean EF was 38.19 6.91%. Two significant lesions (>50%) were identified in two patients. Myocardial fibrosis was observed in 86.1% of the 36 patients, and its quantification was assessed in accordance with the myocardial segmentation scheme and the American Heart Association guidelines The amount of fibrosis is inversely proportional to left ventricular EF (r = 0.52, p = 0.0011), and that the myocardial fibrosis in these patients follows the specific localization pattern of Chagas disease. Our findings reveal that myocardial fibrosis in this patient sub group was not related to coronary obstruction and that the DE pattern is different from the one found in patients who presented ischemic events. Computed tomography DE is also inversely related to left ventricle ejection fraction, another important prognosis marker. Therefore, computed tomography can provide an adequate alternative to MR in the assessment of myocardial fibrosis particularly in patients presenting formal contraindications to MR.
482

Monitorização e mensuração tomográfica de diferentes técnicas de crioterapia em pele de cães da raça Beagle, e sua relação com as medidas da necrose estimadas pela histopatologia / Computed tomography monitoring and mensuration of different cryotherapy techniques on the skin of Beagle dogs and their association with necrosis assessment through histopathological analysis

Ronaldo Lucas 18 November 2004 (has links)
O uso do frio pela medicina é muito antigo, utilizado inicialmente de forma empírica, teve grandes avanços nos séculos XIV e XX, evoluindo juntamente com a Física. O surgimento de novas técnicas e equipamentos, possibilitou à crioterapia tornar-se uma importante opção no tratamento de neoplasias, benignas e malignas, de diferentes órgãos (tais como fígado, próstata, pâncreas e mamas) e sistemas (ósseo, neurológico e tegumentar). O grande desenvolvimento tecnológico permitiu além do maior número de indicações, melhores resultados, mormente com o uso de técnicas de imagem para o acompanhamento do procedimento. Porém, poucos são os trabalhos que enfocam a monitorização e mensuração do congelamento, pela tomografia computadorizada, bem como avaliação da necrose obtida. No presente trabalho propôs-se avaliar as relações entre as medidas obtidas pela tomografia computadorizada, em 20 cães da raça Beagle, durante o congelamento por aplicação do nitrogênio pela sonda fechada (75 segundos), spray (75 e 135 segundos) e derramamento (75 segundos), comparando estas medidas com aquelas mensuradas pela histopatologia da necrose provocada, para posteriormente avaliar a efetividade dos métodos e criar protocolos de tratamento. Os valores de diâmetro, raio, profundidade e volume do congelamento foram comparados entre si e, com os respectivos valores da necrose após 96 horas do procedimento. Os valores foram submetidos a análise de variância de medidas repetidas e teste de Bonferroni (p<0,05). Constatou-se que: a técnica de sonda fechada oferece congelamento e subseqüente necrose mais superficial que os outros métodos, sendo a técnica menos efetiva; em todas as técnicas o volume, diâmetro e profundidade são inferiores no tecido necrosado quando comparados aos seus similares naquele congelado; em nenhuma das quatro técnicas a profundidade de congelamento foi equivalente ao seu raio. Finalmente, houve a possibilidade de desenvolvimento de protocolos alternativos de congelamento a partir da profundidade de necrose pretendida (hf), obtendo-se como resultado (sonda - Di = hf / 0,29; spray I; Di = hf / 0,31; spray II - Di = hf / 0,35; derramamento -Di = hf / 0,38) o diâmetro do congelamento (Di) necessário para o êxito do tratamento / The use of cold by Medicine is a very old practice, initially used empirically, which had significant advances in the XIV and XX centuries, developing along with Physics. The appearance of new techniques and equipment turned cryotherapy into an important option in the treatment of benign and malignant neoplasms in different organs (such as the liver, the prostate, the pancreas and breasts) and systems (bone, neurological and tegumentary). The large technological development resulted in a higher number of indications as well as better results, especially with the concomitant use of imaging techniques to follow the procedure. However, few studies focus on the monitoring and mensuration of freezing through computed tomography, as well as the assessment of the resulting necrosis. Our study aims at evaluating the association between the measurements obtained through computed tomography in 20 Beagle dogs during freezing by liquid nitrogen use through a probe (75 sec), spray (75 and 135 sec) and overflow (75 sec), comparing these measurements to those obtained through histopathological analysis of the resulting necrosis, for later evaluation of the effectiveness of the methods and design of better treatment protocols. The values of diameter, radius, depth and volume of freezing were compared among them and also with the respective necrosis values 96 hours after the procedure. The values were submitted to analysis of variance of repeated measurements and Bonferroni test (p<0.05). We observed that the closed probe technique causes a more superficial freezing and resulting necrosis when compared to the other methods, being the less effective technique. In all techniques, the volume, diameter and depth are lower in the necrotic tissue when compared to those in the frozen tissue; none of the four techniques showed that freezing depth was equivalent to its radius. Finally, alternative freezing protocols could be developed from the depth of the intended necrosis (hf), resulting in the freezing diameter (Di) (probe - Di = hf/0.29; spray I; Di = hf/0.31; spray II Di = hf/0.35; overflow Di = hf/0.38), which is necessary for therapy success
483

Análise crítica comparativa, radiográfica e tomográfica, das alterações do trato respiratório de felinos domésticos portadores ou não de imunodeficiência viral / Critical comparative analysis, radiographic and tomographic appearance, of the respiratory tract disease in domestic cats with immunodeficiency vírus (FIV) and FIV negative cats

Thelma Regina Cintra da Silva 12 December 2012 (has links)
Na rotina de felinos domésticos, algumas modalidades de diagnóstico por imagem, como a radiografia simples e, na última década, a tomografia computadorizada (TC) já são amplamente utilizadas. Este estudo teve por objetivo realizar uma análise crítica da contribuição dos exames radiográfico e tomográfico (simples e contrastado), na avaliação do trato respiratório de felinos portadores ou não de imunodeficiência viral (FIV). Identificando as principais alterações encontradas em felinos FIV+ aos exames radiográfico e tomográfico do crânio e tórax. E ainda, correlacionando os achados radiográficos e tomográficos com os resultados laboratoriais de sorologia para imunodeficiência viral felina, citologia e cultura (bacteriana e fúngica) do lavado traqueal. Foram utilizados 20 felinos adultos jovens de ambos os sexos, sendo 14 FIV+ e 06 FIV-, todos provenientes do mesmo gatil. Pela análise estatística houve um maior percentual de felinos FIV+ com opacificação nas bulas timpânicas pela TC (57,14%) e resultado positivo na análise citológica do lavado traqueal (85,71%). Constatou-se que os felinos portadores de imunodeficiência viral possuíram, por meio da avaliação radiográfica e tomográfica, um maior comprometimento do trato respiratório relacionado às cavidades nasais, bulas timpânicas, parênquima pulmonar e vias aéreas inferiores, quando comparados aos felinos negativos para imunodeficiência viral. / In internal medicine of domestic cats, imaging modalities, such as radiography and, in the last decade, computed tomography (CT) are widely used. The aim of this study was to perform a critical analysis of the radiographic and tomographic contribution in assessing the respiratory tract of feline immunodeficiency vírus (FIV) infected cats and FIV negative cats. Identifying the radiographic and tomographic findings, in FIV+ cats, of the skull and chest examination. And, correlating radiographic and tomographic findings with the laboratory serology for feine immunodeficiency vírus results, cytology evaluation and culture (bacterial and fungal) from tracheal lavage fluid.Twenty young adults cats of both gender were used, 14 FIV+ and 06 FIV-, all from the same cattery. By the statstical analysis there was a higher percentage of FIV+ infected cats with timpanic bullae opacification by the CT examination (57,14%) and positive cytologic evaluation of traqueal aspirates (85,71%). It was found that FIV+ infected cats has greater involvement of the respiratory tract related to the nasal cavity, tympanic bullae, lung parenchyma and lower airways, when compared with FIV- cats.
484

Precisão e acurácia de medidas lineares da mandíbula em imagens 3D obtidas por meio da tomografia computadorizada de feixe cônico / Accuracy and reliability of mandibular linear measurements on 3D CBCT images with different voxel sizes

Thais Maria Freire Fernandes 29 September 2011 (has links)
Objetivo: Avaliar a precisão e a acurácia de medidas lineares da mandíbula por meio da Tomografia Computadorizada de Feixe Cônico (TCFC), alterando o valor do voxel. Material e Métodos: Dez mandíbulas foram submetidas à TCFC seguindo dois protocolos de voxel, 0,2 e 0,4 mm, do aparelho i-CAT Classic. Dez medidas lineares foram realizadas 2 vezes, por 2 examinadores independentes, previamente calibrados, nos cortes multiplanares e nas reformatações 3D no programa Dolphin®. As medidas físicas foram realizadas com um paquímetro digital diretamente nas mandíbulas. Análise de variância para medidas repetidas (ANOVA), coeficiente de correlação intraclasse e o teste de Bland-Altman foram utilizados para avaliar a precisão e a acurácia (p<0,05). Resultados: Excelente precisão intra e boa precisão interexaminadores foi encontrada para todas as variáveis, com exceção da largura interforame mentual entre os dois examinadores nas reformatação 3D. As mensurações realizadas nos cortes multiplanares apresentaram maior acurácia que as mensurações nas reformatações 3D, em relação às medidas físicas. Conclusão: As imagens nos cortes multiplanares em TCFC nos dois protocolos de voxel podem ser utilizadas com precisão e acurácia para a obtenção de medidas lineares quando comparadas com às medidas físicas. Maior cautela deve ser tomada para as reformatações 3D, pois as mensurações neste formato foram precisas, mas não acuradas para todas as variáveis. Um protocolo com menor exposição aos raios X, sem comprometer o diagnóstico, torna-se viável, pois o aumento na resolução das imagens não aumenta a precisão e acurácia na mensuração das medidas lineares avaliadas. / Objective: The purpose of this study was to determine the accuracy and reliability of mandibular linear measurements obtained from 3-dimensional cone-beam computed tomography (CBCT) scans of dry human mandibles using different voxel sizes. Methods: Ten dry human mandibles were scanned at voxel sizes of 0.2 and 0.4 mm. Craniometric anatomical landmarks were identified on the multiplanar reconstructed and on volume rendering images that were generated by the software Dolphin®, independently, by two operators twice. Subsequently, physical measurements were made using a digital caliper. Analysis of variance for repeated measures (ANOVA), Intraclass correlation (ICC) and BlandAltman were used for evaluating accuracy and reliability(p<0.05). Results: Excellent intrarater and good interobserver reliability values were found for linear measurements from CBCT images, with only one exception, interforame width, between observers in volume rendering images. Measurements performed on multiplanar reconstructed images were more accurate than the measurements in volume rendering compared to the gold standard. Conclusion: Linear measurements on multiplanar images of 0.2 and 0.4-voxel are reliable and accurate when compared with direct caliper measurements. Caution should be taken in the volume rendering measurements, because the measurements were reliable, but not accurate for all variables. A protocol with less exposure, without compromising the diagnosis becomes feasible, because an increased voxel resolution did not result in greater accuracy of the measurements and potentially provides increased patient radiation exposure.
485

Estudo dos canais alveolares superiores e do canal infra-orbital por meio da tomografia computadorizada de feixe cônico / Study of the superior alveolar canals and infraorbital canal using cone beam computed tomography

Laura Ferreira Pinheiro Nicolielo 23 August 2013 (has links)
Para oferecer mais informações aos cirurgiões no planejamento de intervenções cirúrgicas maxilofaciais, o presente estudo teve como objetivo avaliar a presença, localização e tamanho dos canais alveolares superiores (CAS), anterior (CASA) e posterior (CASP), canal infra-orbital (CI) e forame infra-orbital (FI) em imagens de tomografia computadorizada de feixe cônico (TCFC) de 100 pacientes adultos (&#x2265; 20 anos), obtidas pelo aparelho i-CAT Classic®. Um examinador calibrado observou a presença dos CAS, CI e FI bilateralmente. Quando presentes, eram medidos comprimento (parte descendente, parte do assoalho da órbita e total), largura e altura do CI; altura, largura e distância ao rebordo inferior da órbita (RIO) do FI; distância da borda inferior dos CAS a crista do rebordo alveolar em 5 regiões: canino (CAN), primeiro pré-molar (1PM), segundo pré-molar (2PM), primeiro molar (1M) e segundo molar (2M); e os diâmetros dos CAS. Foram também observados a localização dos CAS em relação ao seio maxilar e a presença de reparos anatômicos como canal duplo/múltiplo, anastomose intra-óssea e extensão do CASA para a abertura piriforme. Associações entre homens e mulheres, lados direito e esquerdo e regiões foram investigadas para todas as medidas e visibilidade, utilizando separadamente os métodos estatísticos. A presença do CI e FI foi de 100%. A visibilidade do CASA/CASP foi de: 99%/0% (CAN), 99%/21% (1PM), 89%/41% (2PM), 46%/44% (1M) e 7%/61% (2M). As médias dos comprimentos da parte descendente, da parte do assoalho da órbita e total do CI foram de 8,82mm, 19,44mm e 28,35mm, respectivamente. Altura e largura médias do CI foram, respectivamente, 2,08mm e 3,91mm. As médias da altura, largura e distância ao RIO do FI foram: 4,43mm, 5,18mm e 7,52mm, respectivamente. As distâncias médias do CASA ao rebordo alveolar foram: 18,54mm (CAN), 25,47mm (1PM), 28,43mm (2PM), 30,78mm (1M) e 33,21mm (2M); e do CASP: 22,3mm (1PM), 17,65mm (2PM), 15,34mm (1M) e 16,87mm (2M). As médias dos diâmetros do CASA e do CASP foram 0,90mm e 0,83mm, respectivamente, sendo que 77,5% dos CASA e 82% dos CASP eram &#x2264; 1mm e 22,5% dos CASA e 18% dos CASP eram entre 1-2 mm. Em relação ao seio maxilar, 53% e 44% dos CASA foram encontrados no terço superior e médio, respectivamente, e 64% e 36% dos CASP foram encontrados no terço inferior e médio, respectivamente. Houve diferença estatisticamente significativa (p<0,05) entre homens e mulheres para o comprimento, altura e largura do CI; para a altura, largura e distância ao RIO do FI; e para as distâncias dos CAS ao rebordo alveolar. CASA duplo, anastomose intra-óssea e extensão do CASA para a abertura piriforme foram detectados em 24,5%, 38,5% e 84% dos casos, respectivamente. A localização da anastomose foi teve maior ocorrência entre o CAN e 1PM (43%). Os resultados sugerem que a TCFC seja uma ferramenta adequada para examinar os CAS, CI e FI no planejamento de procedimentos cirúrgicos do terço médio da face, a fim de evitar danos a estruturas neurovasculares importantes. / To provide more information to clinicians in planning maxillofacial surgical interventions, the present study evaluated the presence, location and size of the superior alveolar canals (SAC), anterior (ASAC) and posterior (PSAC), infraorbital canal (IC) and infra-orbital foramen (IF) in cone beam computed tomography (CBCT) of 100 adult patients (&#x2265; 20 years old), obtained by i-CAT Classic®. One calibrated examiner observed SAC, IC and IF presence, bilaterally. When present, were measured: length (descending part, orbital floor part and total), width and height of the IC, height, width and distance from the IF to the inferior orbital rim (IOR), distance from the lower border of SAC to the alveolar crest in 5 regions: canine (CAN), first premolar (1PM), second premolar (2PM), first molar (1M) and second molar (2M); and the diameters of SAC. It was also observed the location of SAC in relation to the maxillary sinus floor and the presence of anatomical landmarks such as doble/multiple canal, intraosseous anastomosis and ASAC extension to the piriform aperture. Associations between men and women, right and left sides and regions were investigated for all measurements and presence using statistical methods separately. The presence of the IC and IF was 100%. The presence of ASAC/PSAC was: 99%/0% (CAN), 99%/21% (1PM), 89%/41% (2PM), 46%/44% (1M) e 7%/61% (2M). The mean lengths of the IC descending part, IC orbital floor part and total lenght of the IC were 8.82mm, 19.44mm and 28.35mm, respectively. The mean height and width of the IC were, respectively, 2.08mm and 3.91mm. The mean height, width and distance to the IOR of IF were: 4.43mm, 5.18mm and 7.52mm, respectively. The mean distances of ASAC to the alveolar crest were: 18.54mm (CAN), 25.47mm (1PM), 28.43mm (2PM), 30.78mm (1M) and 33.21mm (2M); and of PSAC: 22.3mm (1PM), 17.65mm (2PM) 15.34mm (1M) and 16.87mm (2M). The mean diameters of ASAC and PSAC were 0.90mm and 0.83mm, respectively, and that, 77.5% of ASAC and 82% of PSAC were &#x2264; 1mm and 22.5% of ASAC and 18% of PSAC were between 1-2 mm. In relation to the maxillary sinus, 53% e 44% of the ASAC were found in the upper and middle third of maxillary sinuses, respectively, and 64% and 36% of the PSAC were found in lower and middle third, respectively. There was a statistically significant difference (p<0.05) between men and women for the length, height and width of the IC, for the height, width and distance to the IOR of IF, and for distances of SAC to the alveolar crest. Double ASAC, intraosseous anastomosis and ASAC extension to the piriform aperture were present in: 24.5%, 38.5% and 84% of the cases, respectively. The location of the anastomosis had more incidence between the CAN and 1PM (43%). The results suggest that CBCT is a suitable tool to evaluate the SAC, IC and IF, assisting surgeons in planning surgical procedures of the midface, in order to avoid damage to important neurovascular structures.
486

Interferência dos artefatos de imagem causados por acessórios ortodônticos metálicos em sobreposições de imagens de TCFC / Influence of streaking artifacts due to metallic orthodontic accessories in CBCT 3D model superimposition

Fernando Penteado Lopes da Silva 06 July 2012 (has links)
O objetivo deste estudo foi avaliar, de forma quantitativa e qualitativa, se artefatos de imagem causados por acessórios ortodônticos metálicos interferem em sobreposições tridimensionais (3D) de imagens de Tomografia Computadorizada de Feixe Cônico (TCFC). Dez crânios secos humanos foram submetidos a três aquisições tomográficas: sem acessórios ortodônticos (T1), com braquetes e tubos ortodônticos de aço inoxidável colados às superfícies vestibulares dos dentes superiores e inferiores (T2), e com fios ortodônticos de aço inoxidável inseridos nas canaletas dos referidos acessórios (T3). Os arquivos DICOM originais foram convertidos em arquivos de imagem Analyze, por meio do software Medsquare. O passo seguinte constituiu-se no registro rígido entre os pares de imagens T2-T1 e T3-T1, por meio do software Bioimage. Após o registro, foram então realizadas as sobreposições 3D entre os referidos pares de imagens, utilizando-se o software MeshValmet. Este software realiza uma codificação por mapas de cores, a partir das distâncias obtidas durante o processo de sobreposição. Distâncias positivas são codificadas com tonalidades de vermelho, enquanto que as negativas recebem tonalidades de azul. A ausência de deslocamento entre estruturas sobrepostas recebem o valor 0,0mmm sendo codificadas com a cor verde. As imagens referentes a T2 e T3 foram sobrepostas em relação à T1 no mesmo plano de espaço, para cada crânio da amostra. A partir das referidas sobreposições, foram calculadas as seguintes medidas: Distâncias Máxima, Mínima e Média, Distância Mean Square (MSD), Distância Root Mean Square (RMS) e Mediana. Estas quatro últimas caracterizaram-se como medidas de tendência central, e representaram a faixa de valores de maior concentração de dados. Os acessórios metálicos causaram artefatos de imagem principalmente nas imagens T2 e T3, porém os mesmos não comprometeram o processo de sobreposição das mesmas em relação à T1. As Distâncias Máximas foram comparadas à medida Diagonal (D), calculada a partir das dimensões dos acessórios ortodônticos e representativa dos mesmos (D=7,5mm). Nesta comparação, o teste t de Student não mostrou diferença significativa (p 0,05) indicando, de forma numérica, que os artefatos não se mostraram estatisticamente importantes em relação às dimensões dos corpos metálicos que os causaram. As medidas de tendência central foram então comparadas ao valor 0,0mm, o qual representa ausência total de deslocamento entre as imagens sobrepostas. Neste caso, o teste t também não evidenciou diferença significativa (p 0,05), indicando que a maior concentração de distâncias entre pontos em T2-T1 e T3-T1 localizou-se próxima ao referido valor. Somado a isso, a avaliação qualitativa propiciada pelas imagens corroborou tal constatação. Na comparação entre as medidas em T2-T1 e T3-T1, os coeficientes de Pearson mostraram alta correlação em relação às medidas de tendência central, como Distância Média (r=0.86), MSD (r=0.87), RMS (r=0.97) e Mediana (r=0.74). Mediante a avaliação quantitativa, complementada pela interpretação qualitativa dos dados, concluiu-se que os artefatos de imagem não comprometeram o procedimento de sobreposição de modelos 3D no presente estudo. / The aim of this study was to determine whether the artifacts caused by orthodontic metallic accessories interfere with the accuracy of three-dimensional (3D) Cone Beam Computed Tomography (CBCT) model superimposition. Ten dry human skulls were subjected to 3 CBCT scans: without orthodontic brackets (T1), with stainless steel brackets bonded (T2) and with orthodontic arch wires inserted into the bracket slots (T3). Individual 3D surface models were generated for the T1, T2 and T3 images, and the within-surface distances between T2-T1 and T3-T1 were computed. Superimposition error was calculated assuming CBCT image registration of T2 and T3 with respect to T1 using plain superimposition. The following measures were evaluated: Maximum, Mean and Mean Square Distance (MSD), Root MSD (RMS) and Median. The metallic accessories caused image artifacts primarily in T2 and T3 images which, however, did not compromise the 3D model superimposition. The maximum distances of artifacts image points were compared to the representative measure of orthodontic accessories (7.5mm), and Student t test showed no significant differences (p0.05) between both measures. When measures of T2-T1 and T3-T1 were compared, the Pearson coefficients showed a high correlation regarding the central tendency measures, as follows: Mean Distance (r=0.86), MSD (r=0.87), RMS (0.97) and Median (r=0.74). The statistical findings, which were complemented by qualitative image data obtained from this study, depicted that streaking artifacts did not affect the accuracy of CBCT 3D model superimposition of dry human skulls.
487

Comparação de grandezas cefalométricas obtidas por meio de telerradiografias e tomografias computadorizadas multislice em crânios secos humanos. / Cephalometric measurement comparison from data obtained by multislice computed tomography and cephalometric radiography in dry human skulls.

Mauricio Adriano de Oliverio Accorsi 28 March 2007 (has links)
Proposição: O objetivo deste trabalho foi comparar medidas cefalométricas lineares obtidas por meio de telerradiografias em normas lateral e frontal, com medidas obtidas com tomografia computadorizada multisclice em terceira dimensão (3D-TC), verificar a acurácia na comparação com o padrão ouro (medidas físicas) e checar a precisão intra-examinador e interexaminadores na localização de 10 pontos cefalométricos. Material e métodos: A amostra estudada consistiu de crânios humanos secos (n=10). As telerradiografias foram obtidas no Departamento de Ortodontia e Odontopediatria da Faculdade de Odontologia da USP, por meio de um aparelho Yoshida Dental, modelo Panoura, e as imagens de 3D-TC foram adquiridas por meio de um tomógrafo computadorizado multilsice de 16 canais, (Aquilion® ? Toshiba) pertencente ao Instituto do Coração de São Paulo, utilizando um protocolo com espessura de corte de 0,5 mm e intervalo de reconstrução de 0,3 mm. Os dados originais foram transferidos para uma estação de trabalho independente com o programa de visualização volumétrica Vitrea®, onde as medidas foram realizadas em terceira dimensão e com o auxílio das reconstruções multiplanares, para permitir a comparação com as medidas realizadas a partir das telerradiografias em normas lateral e frontal, com o auxílio do software Dolphin®. Resultados e Conclusões: As medidas obtidas por meio da 3D-TC apresentaram erros intra-examinador e interexaminadores insignificantes em termos absolutos (mm) e percentuais e, correlações intraclasse elevadas com intervalos de confiança estreitos, para todas as medidas. Com relação à acurácia, a 3D-TC apresentou valores elevados para as correlações intraclasse e intervalos de confiança (95%) estreitos nas comparações com o padrão ouro, para todas as medidas. A técnica que emprega a cefalometria radiográfica convencional apresentou imprecisão para a medida da grandeza Zm(d)- Zm(e) e inacurácia com relação ao padrão-ouro para todas as medidas, com exceção da medida da grandeza Co-Gn, que se mostrou precisa e acurada. A tomografia computadorizada multislice se mostrou mais precisa e acurada do que as telerradiografias em normas lateral e frontal, de forma estatisticamente significante, para a obtenção de medidas em crânios secos. / Proposition: The purpose of this study was to compare linear cephalometric measurements obtained by means of lateral and frontal conventional cephalograms, within measurements obtained by means of a multislice computed tomography in third dimension (3D-CT), verify its accuracy in comparison with the gold-standard (direct physical measurements) and verify the preciseness intra-observer and interobserver for locating 10 cephalometric landmarks. Material and Methods: The sample under investigation was constituted by dry human skulls (n=10). The conventional cephalograms, were taken in the department of orthodontics and pediatric dentistry in the School of Dentistry ? São Paulo University, utilizing a Panoura® X-ray equipment (Yoshida Dental) and the 3D-CT images were obtained utilizing a 16 channel MSCT scanner (Aquilion® - Toshiba) located in the ?Instituto do Coração de São Paulo? (School of Medicine/University of São Paulo). The acquisition parameter was 0,5 mm slice thickness by 0,3 slice rendering. The raw data was transferred to an independent workstation containing the Vitrea® software, where the measurements were made in 3D and aided by multiplanar reformations for posterior comparison with those measurements made over the lateral and frontal conventional cephalograms, using the software Dolphin®. Results and Conclusions: The averages of measurements obtained from 3D-CT were consistently precise and accurate. They shown higher ICC values and short intervals of confidence (95%) in comparison with the gold-standard, in addition, the intra-observer and inter-observer error, were low in absolute (mm) and percent terms. Regarding the conventional cephalograms, the measurement Zm(d)-Zm(e) shown lack of preciseness for intra-observer and interobserver. Were also noticed an inaccuracy for all measurements, in comparison with the gold standard, excepting for the Co-Gn measurement, that presented preciseness and accuracy for both observers. The multislice computed tomography is a reliable method and was statistically significant, more precise and accurate for cranial measurements than the conventional cephalograms.
488

Avaliação da morfologia craniofaciall de indivíduos com deformidades dentofaciais de classe III por meio de tomografias computadorizadas de feixe cônico / Evaluation of the craniofacial morphology of subjects with dentofacial Class III deformities using cone beam computed tomography

Hiroshi Miasiro Junior 03 April 2009 (has links)
A deformidade dentofacial de Classe III está associada a importantes alterações funcionais, psicológicas e estéticas. O objetivo neste trabalho foi avaliar a morfologia craniofacial de indivíduos adultos, com deformidades dentofaciais de Classe III comparando-os com um grupo de indivíduos com faces equilibradas com finalidade de diagnóstico e prognóstico ortodôntico e cirúrgico. Foram avaliados 50 indivíduos, os quais foram submetidos ao exame de tomografia computadorizada de feixe cônico (i- Cat®/ Cone beam 3-D Dental Imaging System, Imaging Sciences International, Hatfield, USA) com o propósito de avaliação e diagnóstico. A amostra foi dividida em dois grupos, sendo 25 indivíduos com equilíbrio das relações faciais e oclusão dentária excelente e 25 com maloclusão Classe III sendo que estes fazem parte da clínica de preparo ortodôntico para Cirurgia Ortognática da Faculdade de Odontologia da FOUSP. Após a obtenção dos arquivos digitais foram realizadas as reconstruções das imagens em três dimensões nos softwares Dolphin 3D® (Dolphin Imaging and Management Solutions, Chatsworth, CA EUA) e Maxilim® (Medicim- Medical Image Computing, Mechelen-Bélgica). Seqüencialmente foram demarcados pontos de referência anatômica e a seguir foram mensuradas grandezas lineares angulares e proporcionais que foram representadas, após avaliação estatística, por média e desvio padrão. Para determinação do erro do método foram calculadas as correlações intraclasses para avaliação da concordância e a fórmula de Dahlberg. Para comparação entre os grupos foi aplicada a Análise de Variância (ANOVA) com dois fatores, destinada a representar a oclusão e gênero. No caso de ocorrência de interação estatisticamente significativa foram realizadas comparações múltiplas de Tukey para verificar em qual dos gêneros dentro de cada grupo ocorreu diferença. O nível de significância adotado foi o de 5%. Com relação ao erro do método foi observada alta reprodutibilidade na avaliação intraoperador nos softwares Dolphin 3D® e Maxilim®. Na comparação cefalométrica 3D entre os grupos avaliados, foram observadas diferenças significativas (p<0,05), sendo que o grupo com deformidades dentofaciais Classe III demonstrou variações para o relacionamento entre altura e largura facial, associada ao aumento da porção inferior da face; rotação horária da mandíbula relacionada à maior inclinação do corpo e do ramo mandibular e pelo predomínio da altura facial anterior em relação à posterior; diminuição do comprimento e do ângulo da base craniana; compensação na altura alveolar da maxila; predominância da dimensão mandibular na configuração ânteroposterior do esqueleto facial e tendências compensatórias verticais que reduziram ao nível alveolar, os desequilíbrios esqueléticos estruturais. / Class III dentofacial deformity is associated with important functional, psychologic and aesthetics changes. The objective of this study was to evaluate the craniofacial morphology of adults, with Class III dentofacial deformity comparing them with a group of subjects with harmonious faces for diagnosis and prognosis in orthodontic and surgical cases. This study evaluated 50 subjects that were submitted to the cone beam computed tomography (i-Cat®/ Cone beam 3-D Dental Imaging System, Imaging Sciences International, Hatfield, USA) with the purpose of diagnosis. The sample was divided in two groups, one with 25 subjects with harmonious faces and excellent occlusion and another with 25 subjects with Class III malocclusion, that are in treatment in the orthodontic clinic for orthognathic surgery in the Faculty of Dentistry of University of São Paulo. After the digital archives were obtained, the 3D reconstruction of images were performed with the softwares Dolphin 3D® (Dolphin Imaging and Management Solutions, Chatsworth, CA EUA) and Maxilim® (Medicim- Medical Image Computing, Mechelen-Bélgica). After demarcation of the reference points, linear, angular and proportional measurements were made and represented in statistical analysis, by mean and standard deviation. To determine the error of method, intraclass correlations were calculated, and Dahlbergs formula was used. To compare both groups the Variance Analyses was applied (ANOVA) with two factors, representing occlusion and gender. When statistical significant differences were observed, Tukeys multiple comparison was performed to evaluate in which gender the variance happened. The level of significance adopted was 5%. The error of method showed high reproducibility for intra-operator evaluation in Dolphin 3D® and Maxilim® softwares. Cephalometric 3D evaluation of the groups, showed significant differences (p<0,05), and the group with Class III dentofacial deformity showed changes in the relationship of height and width, associated with an augmented height of the lower face; clock-wise rotation of the mandible related to an increase of the inclination of the mandible body and ramus and a greater anterior facial height in relation to the posterior facial height; decrease in the size and angulation of the cranial base; compensation in height of dentoalveolar maxilla; predominant mandibular size in anterior-posterior configuration of the facial skull and vertical dentoalveolar compensations that reduced to alveolar level the structural skeletal unbalance.
489

Estudo morfométrico do pedículo cervical / Morphometric study of the cervical pedicle

Anderson Luis do Nascimento 13 February 2017 (has links)
A inserção do parafuso pedicular cervical é um procedimento cirúrgico tecnicamente desafiador. Assim, o amplo conhecimento da morfologia das vértebras cervicais, particularmente do pedículo, é essencial para minimizar o risco de ferimentos graves a estruturas neurovasculares. O objetivo deste estudo foi conduzir uma avaliação detalhada de exames de tomografia computadorizada (TC) na população brasileira do ponto de entrada, trajetória, e dimensões dos pedículos da coluna cervical. Duzentos pacientes consecutivos foram retrospectivamente avaliados utilizando a TC da coluna cervical, com a reconstrução da imagem de cada vértebra no plano axial com 2 mm, e no plano sagital com 3 mm. Os parâmetros no plano axial incluíram a espessura pedicular (EP), o comprimento pedicular axial (CPA), o ângulo pedicular transverso (APT) e a distância do ponto de entrada ao ângulo entre a lâmina e o processo espinhoso (DPE). As medidas no plano sagital envolveram a altura pedicular (AP) e o ângulo pedicular sagital (APS). A EP e AP média são menores nos pacientes do sexo feminino do que nos pacientes do sexo masculino em todas as vertebras cervicais, porém não houve diferença significativa do APT entre os sexos. O APS variou de 15,2° a 23,7°. Os valores médios do CPA e DPE apresentaram uma tendência a diminuir de proximal para distal na coluna cervical. A EP encontrada foi menor que 4 mm em 7,5% dos pacientes do sexo masculino (C3) e em 25% dos pacientes do sexo feminino (C3), e menores que 4,5 mm em 20% dos pacientes do sexo masculino (C3) e em 66% dos pacientes do sexo feminino (C3). A confiabilidade intra e interobservador foram muito boas para a medida tomográfica da EP, e boa para a AP. Para o CPA, a confiabilidade intraobservador foi boa, porém a confiabilidade interobservador variou de moderada a boa. Considerando o APT e APS, a confiabilidade intraobservador foi boa, mas a confiabilidade interobservador moderada para o APT e fraca para o APS. As medidas do DPE evidenciaram fraca confiabilidade intraobservador e fraca ou moderada confiabilidade interobservador. Nossos resultados apresentaram tendência similar aos de estudos prévios, no entanto a frequência de pacientes com a EP < 4,5 mm em nossa população é maior, sugerindo um risco aumentado durante a tentativa de realizar a técnica transpedicular / Pedicular screw insertion is a technically challenged surgical procedure. Thus, extensive knowledge of the morphology of the cervical vertebra, primarily the pedicle, is crucial to reduce severe damage to neurovascular structures. The goal of this study was to conduct a detailed computed tomography (CT) assessment in the Brazilian population of the screw starting point, trajectory, and dimensions of pedicle in the cervical spine. Two hundred consecutive patients were retrospectively evaluated using cervical spine CT, with imaging reconstruction of each cervical vertebra in the axial plane with 2mm, and in sagittal reconstructions with 3mm. Parameters in axial plane included the pedicle width (PW), pedicle axis length (PAL), pedicle transverse angle (PTA), and the distance from the entry point to the point between the lamina and spinous process (DEP). Measurements in the sagittal plane involved the pedicle height (PH) and the pedicle sagittal angle (PSA). The mean PW and PH were smaller in females than in males in all cervical vertebrae, but there were no significant differences of PTA among genders. PSA ranged from 15.2° to 23.7°. Mean values of PAL and DEP had a tendency to decrease from the proximal to distal cervical vertebrae. PW was <4 mm in 7.5% of men (C3) and 25% of women (C3), and <4.5 mm in 20% (C3 male) and 66% (C3 female). The intra- and inter-observer reliability were very good for the tomographic measurement of PW, and good for PH. For PAL, the intraobserver reliability was good, but the interobserver reliability varied from moderate to good. Considering PTA and PSA, the intraobserver reliability was good, but the interobserver reliability moderate for PTA and poor or fair for PSA. DEP measurements showed poor intraobserver reliability, and poor or moderate interobserver reliability. Our results presented similar trend of previous studies, but the frequency of patients with PW <4.5 mm in our population is higher, suggesting an increased risk during the attempting of transpedicular screw technique
490

Foraminas acessórias da região anterior da maxila em tomografia computadorizada de feixe cônico / Additional foraminas in anterior maxilla through cone beam computed tomography

Carla Renata Sanomiya Ikuta 27 October 2017 (has links)
Por meio do exame tridimensional de Tomografia computadorizada de feixe cônico (TCFC) é possível avaliar a área de interesse previamente aos procedimentos com maior precisão. As variações anatômicas são estruturas que devem ser consideradas para a realização de cirurgias, como a foramina acessória da região anterior da maxila (FARAM). O objetivo principal do presente estudo foi avaliar a FARAM, em 150 exames de TCFC, obtidas no aparelho ICat Classic®. Por meio do programa ICat Vision® foram mensuradas o diâmetro, a distância da FARAM ao forame incisivo (FARAM-FI), da FARAM ao rebordo alveolar vestibular (FARAM-RAV) e da FARAM a sutura intermaxilar (FARAM-SI). Também foi avaliada a trajetória dos canais ósseos formados a partir da FARAM. Nos pacientes dentados, foram localizados por meio da área dos dentes: incisivo central, incisivo lateral e caninos. Foi realizada a correlação entre a presença da FARAM e o gênero e a idade. Dos 150 exames, a FARAM estava presente em 21 exames (14%). Destes, dez pacientes eram edêntulos na região de interesse de estudo e não foi possível localizar a foramina em relação aos dentes. Nenhum exame apresentou a FARAM relacionada ao incisivo central, em sete estavam relacionadas ao incisivo lateral e em quatro estavam relacionadas ao canino. Nenhum exame apresentou a FARAM bilateralmente, sendo que treze foram localizadas no lado direito e oito do lado esquerdo. O diâmetro médio da FARAM foi de 1,57 ± 0,38 mm. As médias das distâncias de FARAM-RAV foi de 11,65 ± 3,34 mm, FARAM-FI foi de 8,86 ± 2,72 mm e FARAM-SI, foi de 6,37 ± 2,9 mm. A trajetória do canal ósseo mais comum foi ascendente/oblíqua em direção a região anterior do assoalho da cavidade nasal. A correlação entre a presença da FARAM e o gênero foi estaticamente significante para os homens (p=0,055) no teste do qui-quadrado. No entanto, não foi estatisticamente significante para a idade. / Through cone beam computed tomography (CBCT) is possible to evaluate the region of interest before surgical procedures in tridimensional view. Anatomical variations should be considered for performing surgeries, as the additional foraminas in anterior maxilla (AFAM). The main aim of the present study is evaluate AFAM in 150 CBCT exams, obtained through ICat Classic® device. In ICat Vision® software, the diameter, the distance from the AFAM to the incisive foramen (AFAM-IF), AFAM to the vestibular alveolar ridge (AFAM-VAR) and AFAM intermaxillary suture (AFAM-IS) were measured. It was also evaluated the trajectory of the bony canals related to AFAM. In dentate patients, AFAM was located through the teeth area: central incisor, lateral incisor and canines. The correlation between the presence of FARAM and gender and age was investigated. The AFAM was presented in 21 exams (14%). In the positive exams, 10 patients were edentulous in the region of study interest and it was not possible to locate the foramen in relation to the teeth. Any exam presented the AFAM related to the central incisor, in seven were related to the lateral incisor and in four were related to the canine. Any exam presented the AFAM bilaterally, of which thirteen were located on the right side and eight on the left side. The mean diameter of the AFAM was 1.57 ± 0.38 mm. The distance of the AFAM-VAR 11.65 ± 3.34 mm, AFAMIF was 8.86 ± 2.72 mm and AFAM-IS was 6.37 ± 2.9 mm. The most common bone canal trajectory was upward/ oblique to the anterior region of the floor of the nasal cavity. The correlation between the presence of AFAM and the gender was statically significant for males (p=0.055) in the chi-square test. However, it was not statistically significant for age.

Page generated in 0.107 seconds