• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 90
  • Tagged with
  • 90
  • 90
  • 90
  • 53
  • 52
  • 43
  • 21
  • 19
  • 18
  • 17
  • 16
  • 15
  • 14
  • 13
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Avaliação de pilares de concreto armado colorido de alta resistência, submetidos a elevadas temperaturas. / Evaluation of reinforced HSCC columns at high temperature.

Britez, Carlos Amado 23 March 2011 (has links)
Apesar da quantidade de variáveis envolvidas, ainda persiste uma dúvida na comunidade acadêmica sobre o comportamento do concreto de alta resistência em situação de incêndio, considerando-o como mais ou menos suscetível à ocorrência do fenômeno de desplacamento (spalling) tipo explosivo. Em parte, essa dúvida decorre do fato de que, muitas vezes, os programas experimentais são conduzidos em amostras envolvendo corpos-de-prova padronizados, cilíndricos ou cúbicos, que não levam em consideração a influência de parâmetros relacionados com as dimensões dos elementos estruturais nem com a taxa e configuração das armaduras. Outros aspectos relevantes, como o tipo de agregado utilizado na mistura de concreto, bem como a idade e umidade interna do elemento ensaiado, dificilmente são abordados nas pesquisas e, muitas vezes, simplesmente são omitidos, o que dificulta a visão ampla e real do comportamento térmico do concreto de alta resistência. Esta pesquisa apresenta um programa experimental pioneiro realizado no Brasil em um pilar de concreto de alta resistência, armado, colorido, com idade de oito anos, fc,8anos de 140MPa, agregado graúdo basáltico, agregado miúdo quartzoso, seção transversal de 70cm x 70cm, 200cm de altura, ensaiado sem carregamento e com exposição de três faces pelo período de 180 minutos (3h), sob as temperaturas da curva-padrão de incêndio ISO 834. O pilar protótipo ensaiado é réplica dos pilares reais do edifício e-Tower, construído em 2002, na cidade de São Paulo, Brasil. Os resultados obtidos demonstraram que, neste caso, o concreto colorido de alta resistência comportou-se de forma íntegra frente ao fogo e que a utilização de pigmento à base de óxido de ferro, pode atuar também como um excelente termômetro natural, auxiliando na avaliação da condição da estrutura pósincêndio. / In spite of the several factors that influence the behavior of concrete columns under fire conditions, there is a belief among the research community, that the high-strength concrete is more susceptible to explosive spalling than normal-strength concrete. This doubt, in part, is attributed to the small unreinforced concrete samples (specimens) used in experimental programs, to evaluate the fire resistance of structural concrete. On the other hand, relevant aspects as the coarse aggregate type used in the concrete mixture, as well as the age and content moisture (relative humidity) are not considered in the researches and sometimes simply omitted. This research presents a pioneer experimental program, carried out in Brazil on a high strength colored reinforced concrete column (HSCC) with 200cm high, eight yearsold, fc,8years of 140MPa, basalt coarse aggregate, cross section of 700mm x 700mm, tested under no load and with three faces exposed to a standard fire curve ISO 834 for a period of 180min (3h). The column prototype is a replica of the actual columns of the e-Tower Building, constructed in 2002 in São Paulo city, Brazil. The results demonstrated concrete column integrity under experimental fire and that the iron oxide pigments can work as an excellent natural thermometer, contributing in the evaluation of the structure post-fire.
72

Mitigação da retração autógena em concretos de alta resistência contendo aditivo redutor de retração e seus efeitos na macro e microestrutura / Mitigation of autogenous shrinkage in high strength concrete using shrinkage-reducing admixture and its macro and microstructural effects

Lopes, Anne Neiry de Mendonça January 2011 (has links)
O desenvolvimento do concreto de alta resistência - CAR foi um importante avanço na tecnologia de concreto, entretanto, a despeito de suas inúmeras vantagens como material estrutural, o seu emprego tem sido limitado, por ter se revelado mais susceptível à fissuração nas primeiras idades. Isto se deve à ocorrência do fenômeno da retração autógena, particularmente mais intenso nestes concretos que nos de resistência normal, uma vez que no CAR, há significativamente maior quantidade de material cimentício e menor quantidade de água, o que dá origem a uma estrutura porosa muito refinada logo nas primeiras idades, gerando altas magnitudes de tensões capilares. Além do estudo sobre o entendimento do fenômeno, as pesquisas atualmente têm buscado formas de mitigá-lo a fim de contribuir para estruturas mais duráveis. Diante do exposto, esta pesquisa investigou o comportamento do CAR, no tocante às propriedades mecânicas, elásticas e viscoelásticas e à durabilidade, quando empregado um aditivo redutor de retração - ARR que pode se configurar como estratégia mitigadora para a redução da retração autógena, bem como verificar a sua influência sobre a microestrutura e hidratação da pasta de cimento. Os resultados indicam que o ARR é eficaz na redução da retração autógena e retração por secagem, sem alterar de forma relevante as propriedades mecânicas e elásticas: a resistência à compressão sofre uma pequena queda de 5% com o uso de 2% de ARR em relação ao concreto referência, contudo, as demais propriedades não são alteradas com o uso do ARR. Quanto ao efeito sobre a fluência, não se obtiveram resultados conclusivos. A durabilidade, medida pelos ensaios de penetrabilidade a íons cloretos, permeabilidade à água, carbonatação natural e absorção capilar e por imersão, não é comprometida com a incorporação do aditivo redutor de retração. Do ponto de vista microestrutural, observou-se que o ARR altera o volume total de poros, embora de uma forma não muito expressiva; e ainda constatou-se que este aditivo afeta a velocidade de hidratação das pastas de cimento, e que possivelmente interage com compostos de hidratados da pasta, sem, no entanto, alterar as características macroestruturais do material. / The development of high strength concrete - HSC represented an important advance in concrete technology. However, even knowing that this kind of concrete has several advantages as a structural material, its application is limited by the early ages cracking. This occurrence is due to the autogenous shrinkage phenomenon, once HSC has a greater amount of cementitious material and a lower amount of water in relation to a normal-strength concrete. This condition implies in a greatly refinement of pore structure at early ages which lead to a higher magnitudes of capillary tension than the one observed in a normal-strength concrete. Beyond to study the phenomenon, much research has been conducted in many countries in order to reduce autogenous shrinkage and contribute to more durable structures. So, this research aims to investigate the effectiveness of shrinkage-reducing admixtures – SRA in decreasing the autogenous shrinkage of HSC, and mainly, verify its influence on viscoelastic, elastic and mechanicals properties and durability. The effect of SRA on microstructure and on the cement paste hydration was also investigated. The results show that SRA is effective in reducing the autogenous shrinkage and drying shrinkage without remarkable changes in elastic and mechanical properties. There were not conclusive results related to the creep property. The concrete durability under the action of aggressive agents (such as water, CO2 and chloride) was not influenced by the SRA, information provided by the results of chloride penetration, natural carbonation, water permeability, capillary absorption and absorption of water tests. In a microstructural point of view, it was observed that the addition of SRA results in a small rise in total pore volume. Besides, the results suggest that the SRA affects the rate of cement hydration and it can interact to the hydrated products of paste without implying in great influences on the macrostructural characteristics of the material.
73

Mitigação da retração autógena em concretos de alta resistência contendo aditivo redutor de retração e seus efeitos na macro e microestrutura / Mitigation of autogenous shrinkage in high strength concrete using shrinkage-reducing admixture and its macro and microstructural effects

Lopes, Anne Neiry de Mendonça January 2011 (has links)
O desenvolvimento do concreto de alta resistência - CAR foi um importante avanço na tecnologia de concreto, entretanto, a despeito de suas inúmeras vantagens como material estrutural, o seu emprego tem sido limitado, por ter se revelado mais susceptível à fissuração nas primeiras idades. Isto se deve à ocorrência do fenômeno da retração autógena, particularmente mais intenso nestes concretos que nos de resistência normal, uma vez que no CAR, há significativamente maior quantidade de material cimentício e menor quantidade de água, o que dá origem a uma estrutura porosa muito refinada logo nas primeiras idades, gerando altas magnitudes de tensões capilares. Além do estudo sobre o entendimento do fenômeno, as pesquisas atualmente têm buscado formas de mitigá-lo a fim de contribuir para estruturas mais duráveis. Diante do exposto, esta pesquisa investigou o comportamento do CAR, no tocante às propriedades mecânicas, elásticas e viscoelásticas e à durabilidade, quando empregado um aditivo redutor de retração - ARR que pode se configurar como estratégia mitigadora para a redução da retração autógena, bem como verificar a sua influência sobre a microestrutura e hidratação da pasta de cimento. Os resultados indicam que o ARR é eficaz na redução da retração autógena e retração por secagem, sem alterar de forma relevante as propriedades mecânicas e elásticas: a resistência à compressão sofre uma pequena queda de 5% com o uso de 2% de ARR em relação ao concreto referência, contudo, as demais propriedades não são alteradas com o uso do ARR. Quanto ao efeito sobre a fluência, não se obtiveram resultados conclusivos. A durabilidade, medida pelos ensaios de penetrabilidade a íons cloretos, permeabilidade à água, carbonatação natural e absorção capilar e por imersão, não é comprometida com a incorporação do aditivo redutor de retração. Do ponto de vista microestrutural, observou-se que o ARR altera o volume total de poros, embora de uma forma não muito expressiva; e ainda constatou-se que este aditivo afeta a velocidade de hidratação das pastas de cimento, e que possivelmente interage com compostos de hidratados da pasta, sem, no entanto, alterar as características macroestruturais do material. / The development of high strength concrete - HSC represented an important advance in concrete technology. However, even knowing that this kind of concrete has several advantages as a structural material, its application is limited by the early ages cracking. This occurrence is due to the autogenous shrinkage phenomenon, once HSC has a greater amount of cementitious material and a lower amount of water in relation to a normal-strength concrete. This condition implies in a greatly refinement of pore structure at early ages which lead to a higher magnitudes of capillary tension than the one observed in a normal-strength concrete. Beyond to study the phenomenon, much research has been conducted in many countries in order to reduce autogenous shrinkage and contribute to more durable structures. So, this research aims to investigate the effectiveness of shrinkage-reducing admixtures – SRA in decreasing the autogenous shrinkage of HSC, and mainly, verify its influence on viscoelastic, elastic and mechanicals properties and durability. The effect of SRA on microstructure and on the cement paste hydration was also investigated. The results show that SRA is effective in reducing the autogenous shrinkage and drying shrinkage without remarkable changes in elastic and mechanical properties. There were not conclusive results related to the creep property. The concrete durability under the action of aggressive agents (such as water, CO2 and chloride) was not influenced by the SRA, information provided by the results of chloride penetration, natural carbonation, water permeability, capillary absorption and absorption of water tests. In a microstructural point of view, it was observed that the addition of SRA results in a small rise in total pore volume. Besides, the results suggest that the SRA affects the rate of cement hydration and it can interact to the hydrated products of paste without implying in great influences on the macrostructural characteristics of the material.
74

Estudo teórico-experimental de pilares mistos compostos por tubos de aço preenchidos com concreto de alta resistência. / Theoretical and experimental study of high strength concrete filled steel tubes

Silvana De Nardin 25 March 1999 (has links)
O emprego de pilares mistos formados por tubos de aço preenchidos com concreto de alta resistência, sobretudo em edifícios altos, é uma tendência em diversos países europeus, americanos e asiáticos. A tais elementos são atribuídas vantagens como: alta resistência e ductilidade, economia de materiais e mão-de-obra, redução das dimensões da seção transversal e melhoria no comportamento dos materiais aço e concreto, devido ao efeito de confinamento. Buscando suprir algumas carências de conhecimento, procura-se obter dados experimentais sobre o comportamento de pilares mistos axialmente comprimidos, possibilitando desta forma avaliar parâmetros como influência da forma da seção transversal e da espessura do perfil tubular no seu comportamento. Foram analisadas seções quadradas, circulares e retangulares, preenchidas por concreto com resistência média de 50MPa. A ruína destes elementos caracterizou-se pelo esmagamento do concreto, ocorrendo posteriormente a flambagem local do perfil em diversos pontos. A capacidade resistente prevista por diversas normas resultou em valores muito próximos dos experimentais, embora várias destas normas não considerem o efeito de confinamento. Os ensaios mostraram que o efeito de confinamento contribui de forma decisiva na melhoria do comportamento dos materiais, sobretudo ductilizando o concreto de alta resistência, entretanto seus efeitos não são significativos no aumento da capacidade resistente da seção mista. Alguns critérios para avaliação da ductilidade à compressão foram adaptados e mostraram bons resultados, possibilitando o cálculo do índice de ductilidade. / The use of concrete filled steel tubes especially in tall buildings is a tendency in several european, american and asian countries. The use of these members has several advantages: high resistance and ductility, saving of materials and labour, reduction of cross section dimensions and improvement in behaviour of the materials steel and concrete due the confinement. The main purpose of this study is provide some experimental results of the behaviour of concrete filled steel tubes concentrically loaded. The main experimental parameters considered were the influence of the cross-section shape and thickness of steel tube. Square, circular and rectangular cross-section shapes infilling with concrete of the 50MPa of strength were analyzed. The failure was characterized for crushing of the concrete and later local buckling of the steel section in several points. The strength capacity predicted for several standards showed good agreement with the experimental failure values although this does not consider the confinement of the concrete. The results of tests showed that the confinement effect contributes for improvement behaviour of materials, especially increasing the ductility of the high strength concrete. However the results showed that the triaxial confinement does not increase the axial capacity of the concrete filled steel tubes. Some methods to estimate the ductility of axially compressed concrete columns were adapted and showed good results permitting the calculation of the ductility index of short columns.
75

Lascamento do concreto exposto a altas temperaturas. / Spalling of concrete exposed at high temperatures.

Andréia Azeredo Nince 12 April 2007 (has links)
Esta pesquisa foi motivada pela existência de controvérsia na literatura sobre concreto exposto a altas temperaturas, das dúvidas ainda por solucionar acerca da matéria e da lacuna na norma brasileira para a matéria. Este tema reapareceu após os vários acidentes em túneis ao redor do mundo ocorridos nos últimos dez anos, nos quais se verificou a ocorrência de lascamento explosivo de forma intensa, afetando a estabilidade estrutural. O objetivo principal da tese é correlacionar os parâmetros tecnológicos de dosagem (relação água/cimento, teor de argamassa e consumo total de água) às condições de risco de lascamento, associados à umidade ambiente, que indiretamente, influencia no grau de saturação do concreto. O segundo objetivo é otimizar o uso de fibras de polipropileno para minimizar o efeito do lascamento. Adotou-se empregar a curva-padrão H durante 55 minutos em corpos-de-prova cúbicos aquecidos apenas em uma das fases com sua dilatação térmica lateral restringida. O nível de lascamento foi avaliado usando o volume lascado, obtido pela espessura medida diretamente nos corpos-de-prova, multiplicada pela área lascada, calculada pelo AUTOCAD 2000. Os resultados mostraram que o parâmetro tecnológico mais relevante na ocorrência de lascamento foi a relação água/cimento e a umidade ambiente apresentou capacidade de alterar as condições de risco de lascamento. No estudo com as fibras percebeu-se diferentes teores de fibras e diferentes características das fibras para cada grupo de a/c. Conclui-se que a relação água/cimento mais baixa associada a umidade a ambiente mais elevada é a condição mais propícia a ocorrência de lascamento. Conclui-se também que o teor de fibras de 600g/m³ é o teor mínimo para se reduzir o lascamento no grupo a/c=0,50 e 1750g/m³ no grupo a/c=0,25. A fibra L=12mm F=36µm PF=140°C mostrou-se a mais eficaz no grupo a/c=0,50 apenas o comprimento L=6 mm mostrou-se eficiente na redução do lascamento. / The present research was motivated by the going controversy in the literature about concrete exposed to high temperatures, the yet unanswered doubts existent on this subject and in the absence of regulation on the matter in Brazil. The theme gained significance after the occurrence of several accidents in tunnels all over the world in the last ten years, in which were observed a very intense form of explosive spalling that affected structural stability of the sites. The main purpose of this work is set up a correlation between technological parameters of dosage in concrete (water cement rate -w/c, mortar content - a, and total water consumption - H) and risk conditions of spalling, which are related to environment humidity that indirectly effects concrete saturation level. The second goal is to optimize the use of polypropylene fiber in order to minimize spalling. The standard H curve was applied during 55 minutes in cubic samples with only a single surface exposed to heat and with restrained lateral thermo dilatation. The response variable was the observed volume of spalling (with multiplied by area of spalling in the sample). The results showed the rate water/cement as the most relevant technology parameter related to spalling risk conditions. Whereas the use of fiber is concerned, efficiency required different fiber content and characteristic for each water/cement rate combined with higher environment humidity provides proper conditions for the occurrence of spalling were 600g/m³ and 1750g/m³ for water/cement ratios of 0,5 and 0,25 respectively. It was also found that the fiber with L=12mm, F=36µm PF=140°C was the most effective in reducing spalling for a water/cement ratio of 0,50 whilst for a effective in reducing spalling for a water/cement ratio of 0,50 whilst for a water/cement ratio of 0,50 whilst for a water/cement ratio 0,25 only the length (L=6 mm) appeared as a significant factor.
76

Avaliação de pilares de concreto armado colorido de alta resistência, submetidos a elevadas temperaturas. / Evaluation of reinforced HSCC columns at high temperature.

Carlos Amado Britez 23 March 2011 (has links)
Apesar da quantidade de variáveis envolvidas, ainda persiste uma dúvida na comunidade acadêmica sobre o comportamento do concreto de alta resistência em situação de incêndio, considerando-o como mais ou menos suscetível à ocorrência do fenômeno de desplacamento (spalling) tipo explosivo. Em parte, essa dúvida decorre do fato de que, muitas vezes, os programas experimentais são conduzidos em amostras envolvendo corpos-de-prova padronizados, cilíndricos ou cúbicos, que não levam em consideração a influência de parâmetros relacionados com as dimensões dos elementos estruturais nem com a taxa e configuração das armaduras. Outros aspectos relevantes, como o tipo de agregado utilizado na mistura de concreto, bem como a idade e umidade interna do elemento ensaiado, dificilmente são abordados nas pesquisas e, muitas vezes, simplesmente são omitidos, o que dificulta a visão ampla e real do comportamento térmico do concreto de alta resistência. Esta pesquisa apresenta um programa experimental pioneiro realizado no Brasil em um pilar de concreto de alta resistência, armado, colorido, com idade de oito anos, fc,8anos de 140MPa, agregado graúdo basáltico, agregado miúdo quartzoso, seção transversal de 70cm x 70cm, 200cm de altura, ensaiado sem carregamento e com exposição de três faces pelo período de 180 minutos (3h), sob as temperaturas da curva-padrão de incêndio ISO 834. O pilar protótipo ensaiado é réplica dos pilares reais do edifício e-Tower, construído em 2002, na cidade de São Paulo, Brasil. Os resultados obtidos demonstraram que, neste caso, o concreto colorido de alta resistência comportou-se de forma íntegra frente ao fogo e que a utilização de pigmento à base de óxido de ferro, pode atuar também como um excelente termômetro natural, auxiliando na avaliação da condição da estrutura pósincêndio. / In spite of the several factors that influence the behavior of concrete columns under fire conditions, there is a belief among the research community, that the high-strength concrete is more susceptible to explosive spalling than normal-strength concrete. This doubt, in part, is attributed to the small unreinforced concrete samples (specimens) used in experimental programs, to evaluate the fire resistance of structural concrete. On the other hand, relevant aspects as the coarse aggregate type used in the concrete mixture, as well as the age and content moisture (relative humidity) are not considered in the researches and sometimes simply omitted. This research presents a pioneer experimental program, carried out in Brazil on a high strength colored reinforced concrete column (HSCC) with 200cm high, eight yearsold, fc,8years of 140MPa, basalt coarse aggregate, cross section of 700mm x 700mm, tested under no load and with three faces exposed to a standard fire curve ISO 834 for a period of 180min (3h). The column prototype is a replica of the actual columns of the e-Tower Building, constructed in 2002 in São Paulo city, Brazil. The results demonstrated concrete column integrity under experimental fire and that the iron oxide pigments can work as an excellent natural thermometer, contributing in the evaluation of the structure post-fire.
77

Durabilidade de concretos estruturais com baixo consumo de cimento Portland e alta resistência / Durability of high resistance structural concretes produced with low Portland cement consumption

Markus Samuel Rebmann 06 May 2011 (has links)
Este trabalho apresenta um estudo sobre a confecção de concretos estruturais com baixo consumo de cimento Portland e avalia algumas das suas propriedades no estado fresco e endurecido, tanto em termos mecânicos como de durabilidade. O uso de concretos de baixo consumo de cimento Portland tem por objetivo possibilitar maior sustentabilidade da indústria da construção baseada no concreto, como maior longevidade de jazidas, reduções na emissão de \'CO IND.2\' e no consumo de energia e menores custos de transporte. Possibilita também diversas melhorias técnicas, como menor retração, fissuração e calor de hidratação. Com base em conceitos de empacotamento e dispersão de partículas, uso de adições minerais e fílers e escolha adequada dos materiais, obtiveram-se concretos com baixo consumo de cimento e alta resistência, com consumo relativo de materiais aglomerantes inferior a 5 kg/\'M POT.3\' para produzir 1 MPa de resistência à compressão. Avaliaram-se diversos parâmetros relacionados à durabilidade destes concretos com base em ensaios de absorção de água por imersão, absorção de água por capilaridade, permeabilidade, abrasão, carbonatação e potencial de corrosão. Os resultados obtidos indicam que os concretos de baixo consumo de cimento obtidos podem ter durabilidade comparável ou até superior a concretos usualmente considerados como de bom desempenho. Observou-se que a durabilidade é dependente do tipo de cimento empregado e que deve ser avaliada especificamente com relação ao tipo de ação agressiva a que o concreto estará exposto. / This dissertation presents a study on the development of structural concrete with low Portland cement consumption and evaluates some of its fresh and hardened properties, in mechanical and durability terms. The use of low concrete Portland cement consumption is intended to enable greater sustainability of the construction industry based on concrete, as increased longevity of deposits, reductions in \'CO IND.2\' emissions and energy consumption and lower transportation costs. It also allows several technical improvements, such as reduced shrinkage, cracking and hydration heat. Based on particle packaging and dispersion, use of mineral additives and fillers and appropriate choice of material, concrete with low cement content and high strength was obtained, with relative consumption of binder materials below 5 kg/\'M POT.3\' to produce 1 MPa compressive strength. Various durability parameters were evaluated based on tests such water absorption by immersion, water absorption by capillarity, permeability, abrasion, corrosion potential and carbonation. The results indicate that the low cement consumption concretes may have achieved comparable or superior durability to concrete usually regarded as good performance. It was observed that the durability is dependent on the type of cement used and that durability should be assessed specifically with regard to the type of aggressive action that the concrete will be exposed.
78

Estudo da influência das fibras metálicas no comportamento da aderência entre barras de aço e concretos de diferentes classes de resistência / Study of the influence of steel fibers on the behavior of bond between steel reinforcement and concretes of different strength classes

Igor Vinicius Santana 18 September 2014 (has links)
O emprego e o funcionamento do concreto armado como material estrutural só é possível devido à aderência entre o aço e o concreto. A aderência atua como um mecanismo de transferência de forças, além de garantir a compatibilidade de deformações entre a armadura e o concreto circundante. Inúmeros fatores influenciam no seu comportamento, desde as variáveis relacionadas aos componentes fundamentais do material: como o diâmetro da barra de aço e a resistência à compressão do concreto, até as variáveis que não são essenciais para a sua mobilização como é o caso das fibras metálicas. Sendo assim, buscou-se com o presente trabalho estudar o comportamento da aderência entre barras de aço e concretos de resistência convencional e de alta resistência com adição de fibras metálicas. Para tanto foram pesquisados alguns dos modelos teóricos que se dispõem a representar o comportamento da aderência, como os prescritos pela Associação Brasileira de Normas Técnicas (ABNT) NBR 6118:2003 e o seu projeto de revisão, pela International Federation for Structural Concrete (fib) Bulletin 65: Model Code 2010, pelo American Concrete Institute ACI 318:2014 e os modelos propostos por alguns autores encontrados na bibliografia específica, com posterior comparação dos seus resultados com os resultados obtidos experimentalmente mediante ensaios de arrancamento baseado no procedimento padrão proposto pela RILEM-FIP-CEB (1973). Foram empregadas no estudo experimental, barras de aço com diâmetros de 10 mm e 16 mm em corpos-de-prova moldados com concretos de resistências à compressão de 30 MPa, 60 MPa e 90 MPa. As fibras metálicas utilizadas possuíam comprimentos de 13 mm e 25 mm nos teores volumétricos de 0, 1% e 1,5%, além da hibridização para um volume de 1%. Os resultados experimentais demonstraram que para os teores utilizados, as fibras metálicas não influenciaram significativamente os parâmetros quantitativos da aderência como a tensão última de aderência e o seu respectivo deslizamento, porém foram decisivas para o tipo e a forma da ruptura predominantemente dos concretos de alta resistência. Da analise comparativa entre os resultados experimentais e teóricos verificou-se que os modelos do CEP-FIB (2010) e de Huang et al. (1996), com destaque para este último, foram os modelos que melhor representaram o comportamento da curva tensão de aderência versus deslizamento. Em relação à resistência de aderência de cálculo o ACI 318:2014 foi o código que apresentou os resultados mais conservadores e o código brasileiro, mesmo em seu projeto de revisão, foi o que apresentou resultados com menores diferenças em relação aos valores experimentais. / The use and operation of reinforced concrete as a structural material is only possible due to the bond between reinforcement and concrete. The adherence acts as a mechanism to transfer forces and ensures the compatibility of deformations between the reinforcement and the surrounding concrete. Several factors influence its behavior, since the variables related to the fundamental components of the material: as the diameter of the reinforcement and the compressive strength of the concrete, as the variables that are not essential for its mobilization as the steel fibers. Thus, it sought with this present work to study the behavior of bond between steel reinforcement and conventional strength concrete and high strength concrete with addition of steel fibers. For that, some of the analytical models that seek to represent the behavior of bond were researched as prescribed by the Brazilian Association of Technical Standards (ABNT) NBR 6118:2003 and its project review, by the International Federation for Structural Concrete (fib) Bulletin 65: Model Code 2010, by the American Concrete Institute ACI 318:2014 and models proposed by some authors found in the research literature, with subsequent comparison of its results with those obtained experimentally by pullout tests based on the standard test proposed by RILEM-CEB-FIP (1973). Steel reinforcements with diameters from 10 mm to 16 mm in specimens molded with concretes with compressive strength of 30 MPa, 60 MPa and 90 MPa were used. The steel fibers used had lengths of 13 mm and 25 mm in volumetric rates of 0,1% and 1,5%, in addition to hybridization to a volume of 1%. The experimental results showed that for the rates used, the steel fibers had no significant influence on quantitative parameters of the adherence as the bond strength and its respective slip, but they are decisive for the type and mode of failure of high-strength concrete. The comparative analysis between experimental and theoretical results showed that the models of CEP-FIB (2010) and Huang et al. (1996), especially the latter, were the models that best represented the behavior of the bond stress-slip relationship. Regarding to the design bond strength, the ACI 318:2014 was the model code that presented the most conservative results and the Brazilian code, even in its draft version, presented the results with minor differences from the experimental values.
79

Concreto auto-adensável, de alta resistência, com baixo consumo de cimento Portland e com adições de fibras de lã de rocha ou poliamida / High strength self-consolidating concrete, with low content of cement Portland and addition of polyamide or rock wool fibers

Tobias Azevedo da Costa Pereira 28 April 2010 (has links)
O objetivo deste trabalho é apresentar uma metodologia que possibilita a obtenção de uma linha de concretos auto-adensáveis de alta resistência, econômicos e com reduzido impacto ambiental quando comparados com os concretos correntes. Para atingir estes resultados foram estabelecidos critérios de dosagem e de produção visando à sinergia entre os materiais constituintes do concreto. Foram pesquisados métodos de empacotamento dos agregados e adições minerais, estudada a interação entre o aditivo superplastificante e os materiais cimentícios e a incorporação de fibras de lã-de-rocha ou poliamida. Os concretos com matriz densa sob efeito de temperaturas elevadas tendem a sofrer lascamentos explosivos. Diante disso foi verificado o comportamento de corpos de prova e os resultados indicaram a importância da adição da fibra de poliamida nessa condição, onde o concreto resistiu a uma temperatura de 400ºC. Ensaios de resistência à abrasão indicaram que a fibra de lã-de-rocha melhora essa propriedade do concreto e, como esperado, essa adição não inibe o lascamento explosivo do concreto. Também foram determinadas as propriedades mecânicas dos concretos e concluiu-se que é possível o emprego de um concreto estrutural auto-adensável com consumo de cimento Portland da ordem de 325 kg/\'M POT.3\', fc7 = 53 MPa, fc28 = 71 MPa e Ec28 = 43 GPa. Devido à ação das adições minerais, estes concretos atingiram uma grande reserva de resistência à compressão após a idade de referência de 28 dias, obtendo-se 89 MPa aos 131 dias de idade. A densificação da pasta hidratada, a melhoria da zona de interface desta com os agregados, além da fissuração reduzida decorrente do baixo consumo de cimento e da adição de fibras indicam que este material tem desempenho superior ao prescrito pela NBR 6118 para as diversas classes de agressividade ambiental e de resistência. / The aim of this work is to show a methodology that allows to realize a set of high strength self-consolidating concrete, economic and with lower environmental impact when compared with current concretes. To get these results, criteria for production and mix design had been established aiming at to synergy between constituent materials of the concrete. Methods of particles packing (aggregates and mineral additions), the interaction between the superplasticizer and cementitious materials and the fiber incorporation were researched. The concretes with dense matrix under effect of high temperatures are susceptible to explosive spalling. In this situation, concretes were evaluated by testing cylindrical specimens and results evidenced the importance of the polyamide fiber when the concrete supported 400ºC. Tests of abrasion resistance indicated a good application for the wool-of-rock fiber, but this material not avoids explosive spalling. The mechanical properties of the concretes were determined and show that is possible to product a self consolidate concrete with low cement content (325 kg/\'M POT.3\'), fc7 = 53 MPa, fc28 = 71 MPa and Ec28 = 43 GPa. Due to action of the mineral additions, these concretes had a great reserve of compressive strength after the age of reference of 28 days and achieved 89 MPa at 131 days of age. The high density cement paste, the improvement of the matrix-aggregate interfacial zone and the reduced cracking due to the low cement content and the fibre addition indicate that these materials has superior performance to those prescribed for the NBR 6118 for diverse strength classes and aggressive environmental exposure.
80

Aderência de cordoalhas em concretos de alta resistência com e sem fibras de aço / Bond of strands embedded in plain and steel fiber reinforced high strength concrete

Tatiana Bittencourt Dumêt 25 July 2003 (has links)
Este trabalho apresenta os resultados das investigações teórica e experimental sobre a aderência de cordoalhas pré-tracionadas, em concretos de alta resistência com e sem fibras de aço. Foram utilizadas cordoalhas de sete fios com &#934p 12,7 mm e fibras de aço curtas, com ganchos nas extremidades (DRAMIX) e fator de forma 1/d=45. Foram realizados dois tipos de ensaios: arrancamento e flexão em viga. Os parâmetros estudados foram: comprimento de ancoragem (5&#934p, 7&#934p e 15&#934p), volume de fibra (zero, 40 kg/m3 e 60 kg/m3 e grau de protensão (zero e 0,8fptk). O concreto apresentou resistências à compressão de 50 MPa no momento da transferência da protensão e 68 MPa na data de ensaio, aproximadamente. Os resultados dos dois tipos de ensaio foram analisados e comparados com as prescrições normativas da NBR 6118 (2001), da FIB Bulletin 1 (1999) e do ACI 318 (2002), onde verificou-se que as prescrições se encontram a favor da segurança. A conclusão principal resultante desta pesquisa foi que a utilização de fibras com 40 kg/\'m3 por metro quadrado não influi na aderência. Já para um volume de fibra de 60 kg/\'m3 por metro quadrado há um ganho de aproximadamente 28% na aderência, em relação aos concretos sem fibras de aço, nos ensaios de arrancamento. Para as vigas, não houve ganho de aderência para os volumes de fibra utilizados, nem na determinação do comprimento de transferência, nem na do comprimento de ancoragem necessário. / This study presents the results of a theoretical and an experimental investigation of the bond of pretensioned strands embedded in plain and steel fiber reinforced high strength concrete. There were used seven wires strands with 12,7 mm diameter and short hooked steel fibers with an aspect ratio of 1/d=45. Two types of tests were carried out to obtain the bond characteristics of the strands: pullout tests and beam under flexure tests. The parameters studied were the volume fraction (0%, 0,51% and 0,76%) of the fibers, and the degree of prestress of the strand (zero and 0,8fptk). The concrete compressive strength was 50 MPa at transfer (3 days of age) and 68 MPa at 28 days of age (test date), approximately. The results were analyzed and compared to the provisions of the following Codes: NBR 6118 (2001) (Brazilian code under public consult), ACI-318 (2002) and FIB-Bulletin 1 (1999). The comparison indicated that the codes give a safe design. The main conclusion of this work was that the use of 0,5% of steel fibers does not influence the bond strength of the strand. The use of 0,76% of steel fibers increases the bond stress in 28% when compared with plain concrete, for the pullout tests. For the beam\'s tests there was no bond improvement due to the steel fibers, in both case (0,5% and (0,76%), neither for the transfer length nor for the development length.

Page generated in 0.1404 seconds